Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-10-506
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 144526 Permit Number: RF -3 -10 -506 Scheduled Inspection Date: May 28, 2010 Permit Type: Roof Inspector: Bruhn, Norman Inspection Type: Final Roof Owner: SHEAHAN, TERRENCE Work Classification: Flat Job Address: 326 NE 94 Street Miami Shores, FL Phone Number (305)751 -4918 Parcel Number 1132060136180 Project: <NONE> Contractor: SUNCOAST BUILDERS & ROOFERS Phone: (305)436 -9294 Building Department Comments Inspector Comments Passed CREATED AS REINSPECTION FOR INSP- 142288. CREATED AS REINSPECTION FOR INSP- 139021. Met with contractor and owner about A/C. Failed Correction ❑ Needed Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. May 27, 2010 For Inspections please call: (305)762 -4949 Page 6 of 7 ` SORES M iami S hores V illag e .�� "los Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 0 I'D Tel: (305) 795.2204 Fax: (305) 756.8972 RE: Permit # DATE: 0 y� ���� 0 INSPECTION AFFIDAVIT t � licensed as a (n) Contractor I Engineer / Architect, (Print name and circle License Type) FS 468 Building Inspector License #: C C*C 13 2°7 3 � On or about 0 I did personally inspect the roof deck nailing and (Date & time) secondary water barrier work at 3 (U tf (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) P •'i f Signature State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me this day of Z 2 a {" NOTARY PUBLIC -STATE OF FLORIDA Notary Public, Sate of Florida at Large ° " "'••• Grace Esst ' 9 Commission # T} r�69035 Expires: JUL' 15, 2011 BONDED THRU ATLANTIC BONDLNG CO., INC. 'General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # clearly shown marked on the deck for each inspection Revised on 5/21/2009 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: IN 13 9021 Permit Number: RF -3 -1 -506 Scheduled Inspection Date: April 29 2010 Permit Type: Roof Inspector: Rodriguez, Jorge Inspection Type: Final Roof Owner: SHEAHAN, TERRENCE Work Classification: Flat Job Address: 326 NE 94 Street Miami Shores, FL Phone Number (305)751 -4918 Parcel Number 113206013618 Project: <NONE> Contractor: SUNCOAST BUILDERS & ROOFERS Phone: (305)436 -9294 Building Department Comments Inspector Comments Passed El Failed 52(p P4 q4 Correction Needed Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. April 28, 2010 For Inspections please call: (305)762 -4949 Page 8 of 22 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 139021 Permit Number: RF -3 -10 -50 Scheduled Inspection Date: April 29, 2010 Permit Type: Roof Inspector: Rodriguez, Jorge Inspection Type: Final Roof Owner: SHEAHAN, TERRENCE Work Classification: Flat Job Address: 326 NE 94 Street Miami Shores, FL Phone Number (305)751 -4918 Parcel Number 113206013618 Project: <NONE> Contractor: SUNCOAST BUILDERS & ROOFERS Phone: (305)436 -9294 Building Department Comments Inspector Comments Passed El Failed Correction ❑ Needed Re- Inspection ❑ Fee No Additional Inspections can be scheduled until re- inspection fee is paid. April 28, 2010 For Inspections please call: (305)762 -4949 Page 8 of 22 - '15 ZJ� °R y Miami Shores Village Z 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 A k S 3 5.w ➢5 k f Expiration: 10/0512010 Project Address Parcel N Applicant 326 94 Street 1132060136180 Miami Shores, FL Block: Lot: TERRENCE SHEAHAN Owner Information Address Phone cell TERRENCE SHEAHAN 326 NE 94 ST (305)7514918 MIAMI SHORES FL 33138 -2832 Contractor(s) Phone Cell Phone Valuation: $ 2, 400.00 SUNCOAST BUILDERS a ROOFERS (305)436 -9294 (786)541 -6819 Total Sq Feet: 229 Type of Work: Re Roof Available In spection s: Additional Info: ROOFING Inspe Typ Classification: Residential Tin Cap Final Roof Roof Review Roof in Progress Renailing Affidavit Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $1.80 Education Surcharge $0. Invoice # RF -3-10 -37408 Permit Fee - New Roof $250.00 03/26/2010 Credit Card $ 50.00 $ 213.80 Scanning Fee $9 04/09/2010 Credit Card $ 213.80 $ 0.00 Technology Fee $2.40 Total: $263.80 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. in accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated April 09, 2010 Authorized Signature: Owner / Applicant / Contractor / Agent Date Building Department Copy April 09, 2010 1 Miami Shores Village MCM�, Building Department MAR 2 e07o U 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Y; 42!�_ Tel: (305) 795.2204 Fax: (305) 756.8972 . ......... INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING Permit No. E I CD 0 PERMIT APPLICATION Master Permit No. FBC 20 Permit Type: BUILDING ROOFING Owner's Name (Fee Simple Titleholder) 1® hone # � ®s q 7,� 2 Owner's Address 4ctb lm e s -tw 326 O it City State Zip Tenantlessee Name Phone # Email Job Address (where the work is being done) City Miami Shores Village County Miami -Dade Zip FOLIO / PARCEL # 3v 'O 60 1 3 0 ID Is Building Historically Designated YES NO Flood Zone Contractor's Company Name Qw 1 d e o Z Q2a hone # b 5) 3 D,S A 3 5 Contractor's Address 45/q S w Z I S T City M 1 f r State __ E Zip 33 1 Qualifier Name � 5 _ 1 5 1 na. Phone # ___0 oS) 3 r>? &3 5 State Certificate or Registration No. C � 132 7 8 6 Certificate of Competency No. Contact Phone � 3 0 5 — , 93 5 7 E -mail Sun Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $ Z 4 D 1) Square / Linear Footage Of Work: Type of Work: ❑Addition []Alteration ❑New ❑ Repair/Replace ❑ Demolition Describe Work: ®(a r - to ®® f 0/11 Submittal Fee $ - J0• 00 Permit Fee $ �' CCF $ CO /CC $ Notary $ Training/Education Fee $ ®' Technology Fee $ Scanning $ Radon $ DPBR $ Bond $ Double Fee $ Violation date: Structural Review. $ Total Fee Now Due $ See Reverse side - Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is li�reby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR EWROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signatur Signature Owner or Agent ' Contractor The foregoing instrument was acknnowlled ed before me this The forego' g instrument was acknowle ed before me this day of , 20 �, by - 769 6 2erA n day of , 20 &_, by , who is e to me or who has produced who is person lly known to me or who has produced ' As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Print: CAZ ec- I _ ��a••�•..,, Y LIC -STATE OF FLORIDA My Commission Expires: o Grace Estevez My Commission Expires: " " " ' .. Grace li' stevez - Commission #DD695035 ? Commission #DD69 '•,..,,.." Expires: JULY 15, 2011 '•I . Expires: JULY 15, 2011 ATLANTIC BONDING CO, INC BONDED BONDED Tn1J ' BONDED ATLANTIC BONDING C. INC. atr. F�tr�YAr��k4r�YoYdrdr4e4r9ideak�r3e�9r9rae�k9e9e3r3ctroY 4r4e9i F9e4cdc�tr* �Y3rkdr9e4r4c1k9e8rdnk9e9nY4ra�e4z�Y4edeskdi��r9e4r4r8i�k4e4e4rsYAr9e9ek��k�k8rs' r: YeY9r9idrdrFrFrdr�c4e3rok9i9r�YiYFr3z�ak iii APPROVED BY /' l',r�(� Plans Examiner Zoning Engineer Clerk checked (Revised 07 /10 /07)(Revised 06/10/2009) ACORD CERTIFICATE OF LIABILITY INSURANCE CE OW4RO TLa C81794MM W ISSUED ASA HATiEPtOF Tom .. ONLY AND COMM No JUGM UPON TINE CERTMATE 6191 washwm sued HOMEM TWS CERTOGATE DOES UWARIM EXTEND OR FL. 3!3 ALTER 7i1E (954 NA[C And Roofem Inc A: PREFERRED CONTRACTORS M INSURER 6141 SW 22ct INSURER a F- & 94SURER E COVERPAES VISUREt F_ TM POLICES CW LWM HAVE TO THE ABOVE FM TM ANY REQU . MM OF ANY OR OTHER W M TOWI=H nO "& YBE OR MAY PERTAK THE MOWMEAFFORIAM WTHE MUM IDEMUND HEREIN LR Sl TTO ALLT'HE TMA EMMMMMM CONWOM OF SUCH PW=.AWAWA'MUMnSWMMAYHMWMMRMWMWPM ADM T1fPE P P v.1f #AM EACH 7, ® COMMMM GENIML UAW= WmAGSTOREffm j 74445 03124/10 04=11 ❑❑ CLASS MADE ❑ OCCUR r�ED �' � " 1( A Fl o RU Y 1, ❑ GENERALAGGREGATE 2, oowoo F PRODDM- IM 1, GEN'I.AGGRECiATE L�TAPPLES PER ❑ Poucy ❑ PROJECT ❑ L r COmB9m SlNGLEUwT ❑ ANYAUTO tES ❑ ALL OWNED AUTOS BODILY INJURY B ❑ ❑ SCHEDULED AUTOS ❑ HIRED AUTOS BODILY INJURY ❑ NON OWNED AUTOS (Pa GARA I.IAIIU Y AUTO ONLY -EAACCIDENT C ❑ ❑ ANYAUTO OTHERTHAN FA P= ❑ AUTO ONLY: EXCESS LIABILITY EACH OCCUR El El ❑ CLAMS MADE AGGREGATE _ ❑ DEDUCTIBLE ❑ RETENInOm IOr! AND 0 AFM ❑ EMPLOVEWLIABILM E ANY PITOPRIETOR / PARTNER / DCECUTIVE E I` EACH C*TW4 t / OCCLUDED? E.L. DISEASE - EA ElVLOYEE Ny, desaft under ELL DISEASE -POLICY LrT SPECIAL PROVISIONS below OTdiER F OF OPNBt YKM J LOCATIONS J VEHICLES I EXCLUSIONS ADDED BY ENDORSEMENT I SPECIAL PR OVOOKS z C OMFiCATE BOLDER CANCELL ATHM SHOULD ANY OF THE ABOVE DESCR13W POLICIES BE CANCELLED BEPM THE EXPIRATION DATE THEREOF, THE ISSUM MMER WILL ENDEAVOR TO III CITY OF MIAMI SHORES DAYS WRITTEN NOTICE TO THE CERTOWATE HOLDER NAMED TO 10050 NE 2ND Avenue THE LEFT, BUT FAILURE TO DO SO SHALL UMMSE NO OBUGATION OR UABLffY OF ANY KIND UPA THE B+SURER, ITS AGENTS OR Rl3nMENTAWES. Miami Styes, FL 33138 ATIVE ACRD - - g 199B E - F 03 -09 -2009 ALEX SINK STATE OF FLORIDA CHIEF FINANCIAL OFFICER DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION * CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS' COMPENSATION LAW Z:ONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation law. EFFECTIVE DATE: 03/09/2009 EXPIRATION DATE: 03/09/2011 PERSON: SALINAS MIGUEL A FEIN: 300390478 BUSINESS NAME AND ADDRESS: SUNCOAST BUILDERS & ROOFERS INC 5519 SW 21 ST HOLLYWOOD FL 33023 SCOPES OF BUSINESS OR TRADE: 1- CERTIFIED ROOFING CONTRACTOR 2- CERTIFIED GENERAL CONTRACTOR IMPORTANT: Pursuant to Chapter 440 . 05041. I.S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this section mas not recover benefits or compensation under this chapter. Pursuant to Chapter 440.05(12), F.S., Certificates of election to be exempt... apply only within the scope of the business at trade listed on the notice at election to be exempt. Pursuant to Chapter 440.0503), F.S., Notices of election to be exempt and certificates of eleclimr Io he exempt shall be subject to revocation it. at any time Met the liling of the notice at the issuance of the certificate, the person named an the notice at n•ndicalr no longer meets the tequuemetim of Mr. section to issuance of a cerlilrcaU•. The department shall revoke a certificate at any time lot lailure of the person named on th,• cenifrcate to meet the requiremrnm ul this section. QUESTIONS? (850) 413 -1609 DWC -252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 09 -06 PLEASE CUT OUT THE CARD BELOW AND RETAIN FOR FUTURE REFERENCE STATE OF FLORIDA IMPORTANT DEPARTMENT OF FINANCIAL SERVICES + ' DIVISION OF WORKERS' COMPENSATION i` �� O Pursuant to Chapter 440.05(14), F.S., an officer of a corporation who CONSTRUCTION INDUSTRY , , elects exemption from this chapter by filing a certificate of election CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA <� L under this section may not recover benefits or compensation under this WORKERS' COMPENSATION LAW 6 "°- %' D chapter. EFFECTIVE: 03/09/2009 EXPIRATION DATE: 03/09/2011 Pursuant to Chapter 440.05(12), F.S., Certificates of election to be PERSON: MIGUEL A SALINAS H exempt., apply only within the scope of the business or trade listed on FEIN: 300390478 E the notice of election to be exempt BUSINESS NAME AND ADDRESS: E Pursuant to Chapter 440.05(13), F.S., Notices of election to be exempt SUNCOAS7 BUILDERS & ROOFERS INC and certificates of election to be exempt shall be subject to revocation 6519 SW 21 ST if, at any time after the filing of the notice or the issuance of the HOLLYWOOD. F: 33023 certificate,' the person named on the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the SCOPE OF BUSINESS OR TRADE: person named on the certificate to meet the requirements of this 1- CERTiFIE.7 ROOFING CONTRACTOR 2- CERTIFIED GENERAL CON - RACTOR section. QUESTIONS? (850) 413 -1609 CUT HERE * Carry bottom portion on the job, keep upper portion for your records. Miami shores Village �' Building Department o dIlA k -; 10050 N.E.2nd Avenue i�� RID�'y Miami Shores, Florida 33138 BY: ... °°.... . "" Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE. BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 3 2 2ol b 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: Oa � I ® S Sin Property Address: 3 U IJ ,!C c? q 5f Roofing Permit Number: Dear Building Official: 1 0& L to b QS -n certify that I am not required to retrofit the roof to wall connections of my buil ing because: The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) - T�z j o ( ® ir S S A rN Signature Print Name NOTARY PUBLIC -STATE OF FLORIDA Grace Estevez Commission #DD695035 ''•.,.,,,.. Expires: JULY 15, 2011 State of Florida BONDED MU An AMC BONDING CO., INC. County of Dade The undersigned, being the first duly swom, deposes and says that he /she is the owner for the above property mentioned. Swom to and subscribed before me this z 6 day of A Notary Public, Sate of Florida at Large" -- • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/11/2009 Miami -Dade My Home Page 1 of 2 My Home ° - N MIAAAI•DA E Show Me: Property Information Legend Search By: H q n Property Select Item ., Boundary Selected d Property ® Text onl Property Appraiser Tax Estim street Property Appraiser Tax I �` ORO Highway Comparison de County Portability S.O.H. Calculator r water Summary Details: E N Folio No.: Pro 328 NE 94 ST W P Mailing ERRENCE SHEAHAN &W Address: ORNELIAVOIGT 26 NE 94 ST MIAMI b` 8 g ..- . HORES FL 136 2832 Property Information: 1100 SINGLE FAMILY rimary Zone: RESIDENCE 1 RESIDENTIAL- CLUC: INGLE FAMILY /2 Floors: Livin g Units: 1 Foote e: 243 Digital Orthophotagraphy -2007 0 113 ft Lot Size: 525 SO FT Year Built: 1939 1 53 416 53 42 MIAMI HORES SEC 1 AMD My Home I PromM Information I Property Taxes LegalPB 10 -70 LOT 9 & E1/2 My Neiahhorhood Prop-oft � Description: LOT 10 BLK 46 LOT IZE 75.000 X 127 OR Hq= Using Our Site I A bout I Phone Dire ctary rP lvacv Disclaimer 15546-2765 1291 4 CDC 043 -3667 01 2005 1 Assessment Information: ear: 2009 1 2008 If you experience technical difficulties with the Property Information application, Land Value: 62,778 1$297, 779 or wish to send us your comments, questions or suggestions Buildm Value: $203 914 242,741 please email us at Webmasfer Market Value: $366 692 520 Value: $366,692 rAW 2 Exemption Information: Web Site ear. 2009 1 2008 m 2002 Miami -Dade County. All rights reserved. H $25,000 $25,000 YES YES Taxable Value Information: Year: 2009 2008 Applied Applied Ong Authority: Exemption/ Exemption/ Taxable Taxable Value: Value: Regional: $50,000/ $50,000/ $316,692 $430.128 County: $50,000/ $50,J=/ $316,692 $430128 lty $50,0001 $50,0001 $316,692 $430,128 ool Board: $25,000/ $25,000/ $341,692 $455,128 Sale Information: c.,t., n.,�e• i forvu http: / /gisims2.miamidade.gov /myhome /propmap -asp 3/29/2010 Miami -Dade My Home Page 2 of 2 Wf 901000 -3&67 les which are qualfied Additional Information: r.7ni here to me More information f this ng ity Development District ity Redevelopment Area rment Zone e Zone and Use evelopment Boundary Valorem Assessments http:// gisims2. miamidade .gov /myhome /propmap.asp 3/29/2010 193 Miami shores Village .,, o ,,,M Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Rmp' Tel: (305) 795.2204 Fax: (305) 756.8972 Permit No: 10 -sD Job Name 2010 Page 1 of 1 Building Critique Sheet 2 ', L At &L 44( er ect / Z71LAWL --Iiad 46a 4dif ad a /e 1d re, EAX: WO C�??5 Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 03/31/2010 13:20 FAX 1 800 685 7530 DATA SCAN FIELD SERVICES iM001 T% REPORT TRANSMISSION OR T% /R% NO 4839 RECIPIENT ADDRESS 919549860535 DESTINATION ID ST. TIME 03/31 13:19 TIME USE 00'30 PAGES SENT 1 RESULT OK ®R ,& �. M iami h®res e ills 9 Eggs ,.,.. uildin Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 �l®Rj��l� Tel: (305) 795.2204 Fax: (305) 756.8972 Permit No: 10 - -5-D Job Name J ' j ) , 2010 page 1 of 1 f Building Critique Sheet 4 Z !• 'NC 4 67' 5 HoR� s .,, oil ,,,,,M Miami Shores Village L -.� �� Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RECEIPT PERMIT #: y"1 i D nb(= DATE: , S �� 1 I, I yf' -S S�! � S Contractor ❑ Owner ❑ Architect Picked up 2 sets of plans and (other) ' cY\ -- C0rL 1 -- -`TcC' S Address: 3 ;k7 - ►w From the building department on this date in order to have corrections done to plans And /or get County stamps. I understand that the plans need to be brought back to Miami Shores Village Building Department to continue rmitt�pro. Acknowledged by: PERMIT CLERK INITIAL: RESUBMITTED DATE: Mi Q 0 PERMIT CLERK INITIAL: Property Information Map Page 1 of 1 My Home Miami -Dade County, Florida i Property Information Map Summary Details: Folio No.: 11- 3206 -013 -6180 Property: 26 NE 94 ST ling ERRENCE SHEAHAN &W Address: ORNELIA VOIGT 26 NE 94 ST MIAMI HORES FL v 138 -2832 Propme rmation: 1100 SINGLE FAMILY Primary Zone: RESIDENCE 001 RESIDENTIAL - LUC: INGLE FAMILY Beds/Baths: /2 { Floors: Living Units: 1 S Foota e: 243 Lot Size: 525 SO FT ��. Year Built: 1939 1 53 41 6 53 42 MIAMI { SHORES SEC 1 AMD , Leggy 1 13 10 -70 LOT 9 & E1/2 escription: LOT 10 BLK 46 LOT ;IZE 75.000 X 127 OR r 15546- 2765 12914 COC �\ F2 ° 043 -3667 012005 1 � Assessment Information: ear: 2009 2009 M' ;, Land Value: $162778 297 77 Buildin Value: $203,914 242 741 et Value: $366,692 540,520 Digital Orthophotography - 2007 0 28 ft ark ad Value: $366,692 0,12 This map was created on 3/25/2010 9:01:56 AM for reference purposes only. Ex em tion Information Web Site © 2002 Miami -Dade County. All rights reserved. ear: 2009 1 2008 Ho t d: $25,000 1 $25,000 nd Homestead: I YES I YES Taxable Value Information: Year: 2009 2008 Applied Applied Taxing Authority: Tax bleu/ Exemp Value: Value: Regional: $50,000/ $50,000/ $316,692 $430,128 County: $50,000/ $50,000/ $316,692 $430128 City: $50,000/ $50,000/ $316,692 $430,128 School Board: $25,000/ $25,000/ $341,692 $455128 Sale Information: Sale Date: 1/2005 Sale Amount: 590,000 Sale O/R: 2QMf&7 Sal Q ualification as which are qualified Des cription: vew Additional ales http: / /gisims2 .miamidade.gov /myhome /Printmap. asp? mapurl = http: / /gisims2.miamidade.go... 3/25/2010 of STATE OF FLORIDA 0 DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION . CONSTRUCTION INDUSTRY LICENSING BOARD 1940 NORTH MONROE STREET (850) 487 -1395 WE TALLAHASSEE FL 32399 -0783 SALINAS, LUIS ANTONIO SUNCOAST BUILDERS & ROOFERS INC 6519 SW 21ST STREET MIRAMAR FL 33023 Congratulations! With this license you become one of the nearly one million STATE OF FLORIDA AC# 3 8 3 4 6 2 E Floridians licensed by the Department of Business and Professional Regulation. DEPARTMENT OF BUSINESS AND Our professionals and businesses range from architects to yacht brokers, from PROFESSIONAL REGULATION boxers to barbeque restaurants, and they keep Florida's economy strong. CCC132 - 7864 07/01/08 088000082 Every day we work to improve the way we do business in order to serve you better. For information about our services, please log onto www.myfloridalicense.com. CERTIFIED ROOFING CONTRACTOR There you can find more information about our divisions and the regulations that SALINAS, LUIS ANTONIO impact you, subscribe to department newsletters and learn more about the SUNCOAST BUILDERS & ROOFERS INC Department's initiatives. Our mission at the Department is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida, and congratulations on your new license! IS CERTIFIED wader the provisions of Ch. 0 68 FS Expiration dater AUG 31, 2010 L08070100681 DETACH HERE AC# 3 8 3 4 6 9- 6 STATE_'QF- FLORIDA DEPARTMENT OF BU,INES•S,AND .PROFESSIONAL REGULATION CONSTRUCT ONNA :IUSTRY LICENSING BOARD SEQ# L08070100681 DATE - LICENSE NBR 07 01/2008 088U'00082 CCCL32786,4._` The ROOFING CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 4 & 9 FtS. Expiration date: AUG 31, 2010. SALINAS, LUIS ANTONIO SUNCOAST BUILDERS & ROOFERS,,TNC °. 7 512 NW 55 STREET MEDLEY FL 33166 CHARLIE CRIST CHUCK DRAGO rnuhrnn 03 -09 -2009 ALEX SINK STATE OF FLORIDA CHIEF FINANCIAL OFFICER DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS` COMPENSATION LAW CONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation law. EFFECTIVE DATE: 03/09/2009 EXPIRATION DATE: 03/09/2011 PERSON: SALINAS LUIS A FEIN: 300390478 BUSINESS NAME AND ADDRESS: SUNCOAST BUILDERS & ROOFERS INC 6519 SW 21 ST HOLLYWOOD FL 33023 SCOPES OF BUSINESS OR TRADE: 1- CERTIFIED ROOFING CONTRACTOR 2- CERTIFIED GENERAL CONTRACTOR IMPORTANT. Pursuant to Chapter 440 . 05(14), F.S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this section may not recover benefits or compensation under this chapter. Pursuant to Chapter 440.05021, F.S., Certificates of election to be exempt... apply only within the scope of the business or trade listed on the notice of election to be exempt. Pursuant to Chapter 440.05(13), F.S., Notices of election to be exempt and certificates of election to be exempt shall be subject to revocation if, at any time after the filing of the notice or the issuance of the certificate, the person named on the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the person named on the certificate to meet the requirements of this section. QUESTIONS? (850) 413 - 1609 DWC -252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 09 - 06 PLEASE CUT OUT THE CARD BELOW AND RETAIN FOR FUTURE REFERENCE STATE OF FLORIDA IMPORTANT DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION F Pursuant to Chapter 440.0504►, F.S., an officer of a corporation who CONSTRUCTION INDUSTRY O elects exemption from this chapter by filing a certificate of election CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA L under this section may not recover benefits or compensation under this WORKERS' COMPENSATION ON LAW D chapter. EFFECTIVE: 03/09/2009 EXPIRATION DATE: 03/09/2011 Pursuant to Chapter 440.05(12), F.S., Certificates of election to be PERSON: LUIS A SALINAS H exempt.. apply only within the .scope of the business or trade listed on FEIN: 300390478 R the notice of election to be exempt BUSINESS NAME AND ADDRESS: E Pursuant to Chapter 440.0503►, F.S., Notices of election to be exempt SUNCOAST BUILDERS & ROOFERS INC and certificates of election to be exempt shall be subject to revocation 6519 SW 21 ST if, at any time after the filing of the notice or the issuance of the HOLLYWOOD, FL 33023 certificate, the person named on the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the SCOPE OF BUSINESS OR TRADE: person named on the certificate to meet the requirements of this 1- CERTIFIED ROOFING CONTRACTOR 2- CERTIFIED GENERAL CONTRACTOR section. DUESTIONS? (850) 413 -1609 CUT HERE Carry bottom portion on the job, keep upper portion for your records. DWC -252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 09 -06 t t of �y MIAW .? �V 599213 THIS IS NOT A. Sit,L - .[30;NCIT P AY ' I CAT] SussNl^ss NAME f LOCATION RE NfJ X25:152 - 4 SUNCOAST .BUILDERS &' 'ROOFERS INC STATE #�tC.I51IQ. DOING BUS IN DADE'`CO :OWN R S NCOAST BUILDERS & ROOFERS, INC Sec. T of usiness WEiRKER /S 15� GPNERAL BUILDING CONTRACT THIS }$ ONLY A LOCAL . us SS TAX RECEIPF. ff DOES NOT PERMIT THE HOLDER TO VIOLATE ANY • 'ar ` ^ ,. , EXlS'}'iNO REGULATORY OR i D ZONING N C ES THE: DO NOT FORWARD cclsalutY R crttES. NOR DOES IT EXEMPT THE HOLDER FROM ANY OTHER PERMIT OR LICENSE NO RE QUIRED By FlCA THIS s rs SUNCOAST NOT A CERTIFICATION BUILDERS 81 ROOFERS INC . THE HOLDER'S QUALIFICA TIDNB: LUIS SAUNAS PRES 6 519 SW 21 ST PAYMENT RECEIVED MIRAMAR FL 33023 MIAMMADE COUNTY TAX COLLECTOR: 1 /02120 09 2° 2 0 g d•k y SEE OTHER SIDE f i+ lMULAS ?7 T AX';" � x Wi Ft A«" mgt 'FAQ �k�, �� . IlllAti(7�y � � d •, ay , r .,. i `:4 � t �, � ~K �i z wa ,� 3 ' si 5`,u ; ra ,� K �r , � T � sa �, � !^�"�� 633115-1 THIS IS NOT A,BILL = DO NOT PAY RENEW 1L BUSINESS NAME I LOCATION RECEIPCaIIO: SUNCOAST BUILDERS &ROOFERS, INC-, ESTATE"# CC—C1321,664. OPERATING IN DADE' COUNTY OWNER SUNCOAST BUILDERS & ROOFERSIINC Sec 1 T Vo SPECIALTY BUILDING CONTRACTOR MlORKE3 / ' THIS 9S ONLY A LOCAL. BUSINESS TAX RECEIPT IT . DOES NOT PERMIT THE HOLDER TO VIOLATE ANY EXISTING REGULATORY OR ZONING taws. OF THE DO NOT FORWARD COUNTY OR CITIES, NOR DOES IT EXEMPT THE HOLDER FROM ANY OTHER. SUNCOAST BUILDERS & ROOFERS INC PERMIT OR LICENSE REQUIRED BY LAW. THIS IS - LUIS A S A L I NAS PRE S THE OLDERSOUALIFIC&- 6519 SW 21 ST TIONS, MIRAMAR FL 33023 PAYMENT RECEfVEO MiAMIVOADE COUNTY TAX. COLLECTOR: 10/0212009 02 (� 210026001 k }} { tt 99 000082.50 iY gtl t¢7 11 gtxsf933 ^ Ixi #Iil9fk*,599I i'.t ?9 SS Y9d9?� SEE OTHER SIDE DATE IMM/DD/YY) t ACORD CERTIFICATE OF LIABILITY INSURANCE 03/24/10 PRODUCER Atrium General Insurance THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE 6191 Washington Street HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR Hollywood, FL 33023 _ _ ALTER THE COVERAGE AFFORDED BY THE POLICIES_ BELOW. (954)986 -2333 INSURERS AFFORDING COVERAGE NAIC # j INSURER A PREFERRED CONTRACTORS INS INSURED Suncoast Builders And Roofers Inc _- - - - - — - 6141 SW 22ct INSURER B -____ I INSURER C _ -,_.._ Miramar, FL 33023- _ _ - -. __ _ -._ [ D: INSURER E _ --- COVERAGES INSURER F THE POLICIES OF INSURANCE LISTED HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS ____ - . INSR ADD L I, 1 POLICY EPFECTNE POLICY EXPIRATION LTR �IN$RD i. TYPE OF INSURANCE POLICY NUMBER DATE {MMIDWYYI_ DATE LM LIMITS GENERAL LIABILITY i EACH OCCURRENCE 1,000000 COMMERCIAL GENERAL LIABILITY DAMAGE TO RENTED PC74445 03/24110 02/24/10 1 PREMISES�Ea occurence� MED EXP (Any one person) 1000 i -1 CLAIMS MADE [._] OCCUR A i I j PERSONAL & ADV INJURY 1,000000 GENERAL AGGREGATE 2,000000 1 P COMP /OPAGG� 'I 000000! - ( ] POL CY [ PROJEC 1�1 LOC s I AUTOMOBILE LIABILITY 1 COMBINED SINGLE LIMIT ] ANY AUTO i (Ea accident) -- -- -„ - - -� -- -- - L] ALL OWNED AUTOS BODILY INJURY J B �] `'�� SCHEDULED AUTOS (Per person) HIRED AUTOS I I i BODILY INJURY [] NON OWNED AUTOS (Per accident) 1 - - -- - - - -- - -- PROPERTY DAMAGE -- - (Per accident) ----- - - - - -- - -- - — - — - I GA RAGE LIABILITY ( A UTO ONLY - EA ACCIDENT C i (_] 1 -1 ANYAUTO ' OTHER THAN EAACC_ ] AUTO ONLY: AGG .. - -- - - -- - - - -- - -- - - -.- EXCESS LIABILITY ( EACH OCCURRENCE I I OCCUR ❑ CLAIMS MADE AGGREGATE D u - -- DEDUCTIBLE RETENTION WORKERS COMPENSATION AND i _ j WC STATU 1 OTH- EMPLOYERS' LIABILITY _ TOQY_LIMITS E.R_ E ANY PROPRIETOR / PARTNER / EXECUTIVE E.L. EACH ACCIDENT I i OFFICER /MEMBER EXCLUDED? ----- - -- - -. - - -- - - - - - -- -- - - - - -- i - -- E.L. DISEASE - EA EMPLOYEE If yes, describe under SPECIAL PROVISIONS bel ow E.L. DISEASE POLICY LIMIT OTHER F - -- - - -- - ------- - - - - -- -. -- ! - - -- - -- - -- - DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES / EXCLUSIONS ADDED BY ENDORSEMENT / SPECIAL PROVISIONS L — - --------- - -- - - -- - - - - -- - - - -- .. -- - -- -- .._- --- --- - - - -- -- -- - - - - - -- - - - - - -- -- -- - -- - — - - CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL MIAMI SNORES VILLAGE BLDG DEPT � ' �? _ DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO LE 10050 NE 2ND AVE ( THE FT, BUT FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR REPRESENTATIVES. MIAMI SHORES, FL 33138 ! - - - - -- — - - - - -- -- - - - - -- - - -- A IZED REPRESENTATIVE f I ACORD 25 (2001/08) © ACORD CORPORATION 1988 _ SIhcres ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SY DATE ; P i Florida Building Code Editio0Q_0_7nE ,mT High - Velocity Hurricane Zone Uniform Permit Ap lication Form. S JUUECT 1 CGtv(PUANCE WITH ALL FEDERAL Section d (General lnformaitiW H,N ' (Y,UN,_Y RULES AND REGULATIONS Master Permit No. Process No. Contractor's Name Sy oc a,51 B vi 1 d ef S 4 - G2 ao rS ! a1G Job Address 3 Z 5 A)&Y - n; kor 331 Od " Low Slope ❑ Mechanically Fastened Tile ❑ Mortar /Adhesive Set Till ❑ Asphaltic ❑ Metal Panel/Shingles ❑ Wood Shingles/�4 Shingles MAR 2 2010 ❑ Prescriptive BUR -RAS 150 BY: ROOF TYPE -- -- --- ••• -••- ❑ New Roof 2f/Reroofing ❑ Recovering ❑ Re ii i ai nce ROOF SYSTEM INFORMATION 0 AV Low Slope Roof Area (SF) 2.32° 2 - 0 ' Steep Sloped Roof Area (SF) " X � . 2— $ectinn R (Roof Planl Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. e ot 6 Ct �o r rh� w FLORIDA BUILDING CODE -- '�CIL'DING• • • • . :. : • •; ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. Section C (Low Slope Application) Surfacing: Fill in specific roof assembly components and identify manufacturer Fastener Spacing for Anchor /Base Sheet Attachment: (if a component is not used, identify as "NA ") r! Field: 6 " oc @ Lap, # Rows Z. @ " oc System Manufacturer: 6 '! °�1 e, A v Perimeter:" oc @ Lap, # Rows -q— @ AL" oc Product Approval No.: fir ���'} �, ;l� Corner: " oc @ Lap, # Rows � @ 6 " oc Design Wind Pressures, From RAS 128 or Calculations: 00 Number of Fasteners Per Insulation Board: Pmaxl : � Z Pmax2: AZ , (o Pmax3: ) 2 4• JJ �1 Field /6/ / CornerU Max. Design Pressure, from the'specific Product Approval system: - � t`, Illustrate Components Noted and Details as Applicable: Deck: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Type: '_ Continuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. Gauge /Thickness: Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Slope: e rg ,' Z Type, Fastener Spacing or Submit Anchor /Base Sheet & No. of Ply(s): Anchor /Base Sheet Fastener /Bonding Material: Insulation Base Layer: Base Insulation Size and Thickness: Base Insulation Fastener /Bonding Material: - -, Parapet a;t Height _ Top Insulation Layer: Top Insulation Size and Thickness: — -- F - - -- -- - - ---^- Top Insulation Fastener /Bonding Material: Mean Roof , { Base Sheet(s) & No. of Ply(s): 01 1 r r lion n Height .._......... _._... Base Sheet Fastener /Bonding Material: ) t ° A e_ r\ cr r l)UL e Ply Sheet(s) & No. of Ply(s): do., -C� ' e- elm s g 3wSc Ply Sheet Fastener /Bonding Material: Top Ply: 9t\L ely 06� T="re- S Tizby. 22 (a S . Top Ply Fastener /Bonding Material: ) go Vn o / 111 6t Q� cLa oVC cL5 1 �f– FLORIDA BUILDING CODE — BUILDING Y 'ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. Section D (Steen Sinned Roof System) Roof System Manufacturer: Notice of Acceptance Number: Minimum Design Wind Pressures, 1 pplicable (From RAS 127 or Calculation s))• A : P2 P3: Maximum Design Pressure -I/ (From the Product Approval Specific System): Steen Sloped Roof System Descrintien ..... Deck Type Type Underlayment R�Slope — Insulation. i Fire Barrier Ridge Ventilation? `. Fas Cner Type & Spacing: Adhesive Type. ' Type Cap Sheet: Mean Roof Height: Roof Covering I • Type & Size Drip .. • I Edge: ... *0 -- • •• 0 ' 000 0 • • • •.. FLORIDA BUILDING CODE 6w' G' 00 • • •'• • • ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. Section F (Tile Calculations) For Moment based tile systems, choose either Method l or 2. Compare the values for M with the values from M If the M values are greater than or equal to the M, values, for each area of the roof, then the tile attachment method is acceptable. Method I "Moment Based Tile Calculations Per RAS 137" (P x h. _ ) - Me: = M,.I Product Approval Mf (P,: /?, = 1 - Mg: = M Product Approval M (P3: x X _ ) - Mg: = M Product Approval M Method 2 "Simplified Tile Calculations Per Tuble Below" Required Moment of Resistance (Mr) Front Table Below Product Approval M M re uired Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 4 30-4 322 33.9 35A 37-3 5 28A in 1 31.6 328 34-9 7A2 244 25.9 28.2 30.0 "Must be used in conjunction with a list of moment based the systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Moment Based Tile Calculations Per RAS 127" W : x l: = x w: _ ) - W: x cos 8 = F,. Product Approval 1F` (P,: x 1.. = x . _ ) - W: x cos © = Fr2 Product Approval F' x I. _.._ ......... ..._.. _. —._.__ / w: _ .._. - - -.) - W: _..__.._.__. x cos © - - -- = F q Product Approval f -- Where to Obtain Information Description Symbol Where to find Desi Pressure PI or P3 or P3 RAS 127 'fable I or bv an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Sloe 0 Job Site Aerod mamic. Multiplier 1 Product Approval royal Restoring Moment due to Gravity l4 Product Approval Attachment Resistance M Product Approval Required Moment Resist nc • • • Cakoiated Minimum•%ttacsi�te • • '', • • • • • • • • • • •I• lrtdect Approval RAtstance • i i Re uired t) Milt Resistance I r Calculated ••• ••• ••• • ve e le Wei, • W • Product•A . royal • • � • • • 1!= 1�nflth • • • 7 . ile 13imensiorlt • • • Vrodtw,Approval W = width All calculatiot st jaesubrilitted to the buildin official at the time of permit application. FLORIDA BUILDING CODE — BUIL • •' • • ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 4402.14 HIGH - VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Attachments Required Permit Application Form See List Below Low Slope Application ABC 1 2 3 4 5 6 7 Prescriptive BUR -RAS 150 ABC 4 Asphaltic Shingles A B D 1,2,4,5,6,7 Concrete or Clay Tile A B D E 1,2,3,4,5,6,7 Metal Roofs ABD 1 2 3 4,5,6,7 Wood Shingles and Shakes ABD 1 2 4 5 6 7 Other As Applicable 1,2,3,4,5,6.7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings ..3.. .Design Calcylationp Chapter 16, or If Applicable, RAS 127 or RAS • 28 0 0 " 4' Othtt C enent of Product Approval 5. Munici al Permit Application . . . .. . • • �. .Ovvrs ?OtViftio[ft Roofing Considerations Reroofin Onl 7. Any Re ui'ed Roof T'estin /Calculation Documentation . . . . . . . . . . FLORIDA BUILDING CODE— BUIL61NGf SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. Aesthetics - Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renal ed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. 1_ Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. _ Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. Ponding water: The current roof system and /or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. _ Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. ??> .V6nf1Midh :WQ1t, o0f Structeres should have some ability to vent natural airflow through the interior of the' %truotdre -a9se nb'y ;t* funding itself). The existing amount of attic ventilation shall not be reduced. It May IV beneftcialetd consider additional venting which can result in extending the service life of the roof. fee �► Owner /Agent s tigpature .. Data f Contractor S' nature Date Revised on 7/9/2009 LO . . . . . . . . . . MIAMI DADE MIAMI -DADE COUNTY, FLORIDA - METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOTICE OF ACCEPTANCE (NOA) Firestone Building Products Company 310 East 9e Street Indianapolis, IN 46240 -3702 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Firestone Modified Bitumen Roof Systems over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 03- 0819.04 and consists of pages 1 through 34. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 05- 0830.10 Expiration Date: 03/08/11 Approval Date: 12/29/05 Page 1 of 34 ROOFING SYSTEM APPROVAL Category: Roofing Sub - Category Modified Bitumen Material: APP /SBS Deck Tvue: Wood Maximum Design Pressure -52.5 psf Fire Classification: See General Limitation #1 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description APP 180 39.4" x 32'10" ASTM D 5147 Polyester reinforced modified bitumen, granule surfaced membrane. Torch applied. APP 180 FR 39.4" x 32'10" ASTM D 5147 Polyester reinforced, fire regardant modified bitumen, granule surfaced membrane. Torch applied. APP 170 39.4" x 33'6" ASTM D Polyester reinforced modified bitumen membrane. Torch applied. APP 160 39.4" x 32'10" ASTM D 5147 Polyester reinforced modified bitumen membrane. Torch applied. MB Base Sheet 36" x 108' ASTM D 5147 Fiberglass reinforced base sheet, asphalt coated on both sides. Applied in hot asphalt or mechanically attached. SBS 39.4" x 33'10" ASTM D 5147 Granule surfaced, modified bitumen membrane reinforced with non -woven polyester mat. SBS FR 39.4" x 33'10" ASTM D 5147 Ceramic granule surface, modified bitumen membrane reinforced with non -woven polyester mat. SBS Premium FR 39.4" x 33'10" ASTM D 5147 Ceramic granule surface, fire rated, modified bitumen membrane reinforced with non -woven polyester mat. SBS Base Sheet 39.4" x 50' ASTM D 5147 Fiberglass reinforced SBS base sheet. Applied in hot asphalt or mechanically attached. SBS Smooth 39.4" x 33'10" ASTM D 5147 Smooth surfaced, modified bitumen membrane reinforced with non -woven polyester mat. Applied in hot asphalt. SBS Premium 39.4" x 33'10" ASTM D 5147 Granule surfaced, modified bitumen membrane reinforced with polyester mat. Applied in hot asphalt. 4 NOA No.: 05- 0830.10 y Expiration Date: 03/08/11 Approval Date: 12/29/05 Page 2.of 34 Test Product Product Dimensions Specification Description SBS Glass 39.4" x 33'10" ASTM D 5147 Fiberglass reinforced, granule surfaced, modified bitumen membrane. Applied in hot asphalt. SBS Glass FR 39.4" x 33'10" ASTM D 5147 Granular surfaced, fiberglass reinforced, fire regardant, modified bitumen membrane. Applied in hot asphalt. Type IV 33" x 180" ASTM D5147 Fiberglass reinforced, asphalt impregnated, roofing ply. Applied in hot asphalt. Type VI 33" x 180" ASTM D5147 Fiberglass reinforced, asphalt impregnated, roofing ply. Applied in hot asphalt. APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer �x Isocyanurate Insulation (With Current NOA) Y Apache ACFoam I, ACFoam 11 Isocyanurate Insulation Atlas Roofing Corp. ISO 95 +, ISO 95+ GL, 95+ GW Isocyanurate Insulation Firestone ISO 95+ Composite Isocyanurate Insulation with perlite facer Firestone Fiber Top Regular wood fiber insulation Firestone Rhoflex Composite Polyisocyanurate foam / perlite insulation Firestone Dens Deck Silicon treated gypsum G -P Products ENRGY 2, ENRGY PSI -25, Isocyanurate Insulation Johns Manville U1traGard Gold 11, U1traGard H Fiberglas Fiber glass roof insulation Johns Manville Fesco Foam Isocyanurate Insulation with perlite facer Johns Manville High Density Wood Fiberboard High Density Wood Fiber insulation Generic board. Perlite Insulation Board Perlite Insulation Generic Iso -Lite E Polyisocyanurate foam insulation International Permalite Multi -Max FA Isocyanurate Insulation Rmax Inc. NOA No.: 05- 0830.10 Expiration Date: 03/08/11 Approval Date: 12/29/05 Page 3 of 34 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Firestone All- Purpose Insulation and membrane Various Firestone Fastener fastener 2. Firestone HD Fastener Insulation and membrane Various Firestone fastener 3. MB Barbed Metal Metal plates used for 2" dia Firestone Seam Plate membrane securement. 4. Hexagonal Plate Insulation attachment 3 - / x 2- Firestone hexagonal plate 7 / $ " 5. Seam Plate Membrane seam attachment 2 - dia Firestone plate. 6. Metal Plate Membrane attachment plate. 2" dia Firestone 7. Dekfast Fasteners Insulation and membrane Various Construction fastener Fasteners, Inc. 8. Dekfast Hex Plate Insulation and membrane Various Construction fastener Fasteners, Inc. 9. #12 & #14 Roofgrip Insulation and membrane Various ITW Buildex fastener 10. Metal Plate Galvalume AZ50 stress plate 3" square ITW Buildex 3" round 11. Plastic Plate 3.2" round polyethylene stress 3.2" round ITW Buildex plate 12. Olympic Fasteners Insulation and membrane Various Olympic Mfg. Group fastener 13. Olympic Standard 3" round Galvalume AZ55 3" round Olympic Mfg. Group stress plate 14. Olympic Plastic plates for fasteners. 3" ro und Olympic Mfg. Group 15. Insul-Fixx Fastener Insulation fastener for use in Various SFS Stadler, Inc. wood, steel and concrete decks 16. Insul -Fixx S Galvalume AZ55 stress plate 3" round SFS Stadler, Inc. 17. Insul -Fixx PG Polyethylene stress plate 3" round SFS Stadler, Inc. . 18. Tru -Fast Fasteners Insulation and membrane Various The Tru-Fast Corp. fastener 19. Tru-Fast MP -3 3.23" round Galvalume AZ50 3.23" round The Tru-Fast Corp. steel plate NOA No.: 05- 0830.10 Expiration Date: 03/08111 Approval Date: 12/29/05 Page 4 of 34 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 20. Tru-Fast Plastic Plate 3" round polyethylene stress 3 round The Tru -Fast Corp. plate EVIDENCE SUBMITTED: Test Agency Test Identifier Description Date Factory Mutual Research Corp. J.I. 1D5A8.AM Wind Uplift Classification 09/09/98 Factory Mutual Research Corp. J13003597 Wind Uplift Classification 07/14/99 Factory Mutual Research Corp. J.I. 3004786 Wind Uplift Classification 05/16100 Factory Mutual Research Corp. J.1. 3005030 Wind Uplift Classification 08/08/00 Trinity Engineering, Inc. 4810.01.96 -1 Uplift Resistance 01/31/96 PA 114(C) and PA 114(D) Exterior Research & Design, LLC. 4810.10.96 -1 Uplift Resistance 10/31/96 PA 114(7) ACRC, LLC. ACRC 03001 TAS 114 03/06/03 ACRC, LLC. ACRC 03007 TAS 114 05/01/03 Y NOA No.: 05- 0830.10 Expiration Date: 03/08/11 Approval Date: 12/29/05 Page 5 of 34 Membrane Type: SBS Deck Type 1I: Wood, Non - insulated Deck Description: 19 /32" or greater plywood or wood plank fasten to supports with #8 x 1 -5/8" wood screws at a maximum spacing of 6" o.c. System Type E(2): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of Firestone MB Base mechanically fastened . to the wood deck as described below: Fastening #1: Base sheet shall be lapped 4" and fastened with Firestone #14 AP fasteners 3" Round Metal Plates 12" o.c. in the lap and two rows staggered in the center of the sheet 12" o.c. Fastening #2: Base sheet shall be lapped 4" and fastened with approved roofing nails and tin caps 6" o.c. at the lap and two rows staggered in the center of the sheet 6" o.c. Ply Sheet: One or more plies of SBS Smooth or SBS Base sheet or Firestone Type IV or VI ply sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 401bs. /sq. Membrane: One ply of Firestone SBS, SBS FR, SBS Smooth, SBS Premium, Premium FR, SBS Glass or SBS Glass FR adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 401bs. /sq. Surfacing: (Optional) Install one of the following: 1. Gravel or slag at 400 lb. and 300 lb., respectively, set in a flood coat of type III or IV asphalt at 60 lb. /sq.. 2. Karnak No. 97, No. 97 AF at an application rate of 1 /z gal. /sq.. Maximum Design Pressure: —52.5 psf (See General Limitation #7) NOA No.: 05 -0830.10 Expiration Date: 03/08111 Approval Date: 12/29/05 Page 33 of 34 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LmTATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings,of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 401bs./sq., or mechanically attached using the fastening pattern of the top layer 3, All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 2751bf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 05. 0830.10 _ . JL Expiration Date: 03/08111 Approval Date: 12129/05 Page 34 of 34 2006 ROOFING MATERIALS AND - SYSTEMS DIRECTORY ` 146 ROOF COVERING MATERIALS (TEVT) ROOF COVERING MATEF Roofing Systems (TGFU)— Continued Roofing Systems (TGFL COLD APPLICATION SYSTEMS Surfacing: Roofing gravel embeddec Class A 3ga1 /sq 1. Deck: NC Incline: 1/2 Class B Insulation (Optional): Firestone "ISO 95 +GL ", "FiberTop C ", "E" or 1. Deck- C -15/32 1 "S"; any thickness, or any UL Classified polyisocyanurate, perlite, Base Sheet: One layer "MB Base She fiberglass or wood fiberboard, any combination, any thickness, mechani- Premium Base Base Sheet ", mechanically fast cally fastened or hot mopped. Ply Sheet (Optional): One layer "M Base Sheet: One layer Firestone "Ply IV Felt"; "Ply VI Felt ", "MB Base "Modified Bitumen Cold Adhesive" at 1 Sheet ", "SBS - 'Base Sheet ", "SBS Premium Base (Sheet or any UL Membrane: "SBS Glass FR ", adhered Classified Type • G1 or G2, mechanically fastened or adhered with Adhesive" at 1 -1/2 gal /sq. Firestone 'Modified Bitumen Cold Adhesive" at 1 -1/2 gal /sq. 2. Deck: C -15/32 Ir Membrane: Firestone "SBS Glass FR ", "SBS Premium FR ", adhered Base Sheet: One layer "MB Base She( with Firestone "Modified Bitumen Cold Adhesive" at 1 -1/2 gal /sq. Premium Base Sheet ", mechanically fast4 2. Deck: C- Incline: 1/2 Ply Sheet: One layer "MB Base Sheet," Base Sheet: One layer "MB Base Sheet ", "SBS Base Sheet" or'SBS "Modified Bitumen Cold Adhesive" at 1 Premium Base Sheet ", mechanically fastened. Membrane: "SBS FR ", "SBS Premium Ply Sheet:: One layer "MB Base Sheet ", "SBS Base Sheet" or "SBS Bitumen Cold Adhesive" at 1 -1/2 gal /sc Premium Base Sheet", adhered with "Modified Bitumen Cold Adhesive" 3. Deck: C -15/32 Iit ' � I • at 1 -1/2 gal /sq. Base Sheet: 1 ply "IvtB Base Sheet" Membrane: "SBS Glass FR ", adhered with "Modified Bitumen Cold mechanically fastened ! I j Adhesive" at 1 -1/2 gal /sq. Membrane: 1 ply "APP 180' FR Coop' 3, Deck-.NC Incline: 1 Adhesive" at 1 -ih gal /sq I Insulation (Optional): Any UL Classified, any thickness, mechanically COMBINATION HOT & CC I l' attached, hof mopped or set in "Modified Bitumen Cold Adhesive" Class A 1. Deck: NC �' i Base Sheet: One or more plies of the following: "MB Base Sheet ", In "Rhoflex'Base Sheet ", any combination set in Modified Bitumen Cold I Insulation: Isocyanurate, perlite, isocya Adhesive ". and glass fiber, any thickness, mechanicall Ply Sheet (Optional): •:One or more plies "Rhoflex Smooth" set in roofing asphalt, any combination. "Modified Bitumen Cold Adhesive ". Base Sheet: One ply Type:Gl =or G2, meo Membrane: "Rhoflex Smooth ", "Rhoflex Granular" or "Rhoflex FR" set mop ed. „ P in "Modified Bitumen Cold Adhesive ". ( "Rhoflex Smooth" and "Rhoflex Ply Sheet: Two or more plies Type Gl or Granular" require the use of Karnak "97 AP" or "Aluminum Fibered asphalt. Roof Coating" at 1 -1/2 gal /sq), p Base Coat: "Fibered Asphalt EmulsioeA I it I 1 y i 4. Deck 1 / C -32 " Incline: 1�2 Intermediate Coat: "ACRYLICBaseCoa I Base Sheet ' Two or layers "MB 'Base Sheet" or "Rhoflex Base Top Coat: "PC -100 Coating' ", 1 gal /sq. Sheet 'mechanically aftached or set in "Modified Bitumen Cold Adhe- 2. Deck: NC Inn I I sive . Insulation: Isocyanurate, perlite, isocyar { i Ply Sheet (Optional): One layer "Rhoflex Smooih" set in "Modified and glass fiber, any thickness, mechanicallj f I li I Bitumen Cold Adhesive ". roofing asphalt, any combination. I II 'Membrane: "Rhoflex Smooth ", "Rhoflex Granular or "Rhoflex FR" set Base Sheet: One ply Type Gl or G2, mec 1 in "Modified Bitumen Cold Adhesive ". ( "Rhoflex Smooth" and "Rhoflex mopped. Granular" require the use of Karnak "97 AF" or "Aluminum Fibered Roof Coating" at 1 -1/2 gal /sq) Ply Sheet: Three or more plies Type Spa; I' . roofing asphalt. it li Surfacing: "Fibered Asphalt Emulsion 5. Deck: C -15/32 _ Incline: 1/2 I` Insulation (Optional): "ISO 95 +GL" or any other : UL Classified SINGLE PLY MEMBRA polyisocyanurate, any thickness, loose laid,or mechanically fastened. Class A - Ballasted ll II �j Barrier Board: G - Gypsum "DensDeck8" or "DensDeck Prime ® ", 'Unless otherwise indicated, the insulation AM ;min 1. /� in. thick, mechanically, fastened. As an alternate, the insulation ma y be mechank , Base Sheet (Optional): `MB Base Sheet" or any other UL Classified screws and metal or plastic discs, hot roof,, " screws /discs and hot roofing as halt. Type. Gl or 'lypg G2; hot mopped or mechanically fastened. An optional pp p l layer of gypsum oard m#y , b Base Sheet: 'SBS Base Sheet ", hot mopped or adhered- with "Modified and the roof deck on all systems. i z Bitumen ,ColdtAdheisve ", max 1 -1/2 gal. /sq. As an alternate, the membrane be y Membrane: "SBS FR ", hot mopped or adhered with 'Modified Bitumen 2004 Bonding Adhesive" or "Tri umph Bow Cold Adheisve ", max 1 -1/2 gal./sq. insulation and to the �I membrane at 1 -2/3 6. Deck: C -15/32 Incline: Y2 tions). The lap splices are sealed with' -'S,A I I 'j I Base sheet: 1 or more. plies "MB Base Sheet" or "APP 80 Glass -Base Splice Adhesive Pl(s" or "Triumph Splice A i Cool" or Firestone "Type IV Felt" or Firestone "Type VI. Felt" mechani- 150 to 175 lin ft per gal (3 in. lap coated both cally fastened 130 to 150 lin ft per gal. (4 in. lap coated b Ply Sheet: 1 ply Firestone "Type IV Felt 5 P e or Firestone ='T VI Felt" also be sealed with "QuickSeam Sphce Taps' Tape ". The edges of the laps, are seal y 029 r ' � "MB Base Sheet" or "APP 80 Glass Base Cool" or full adhered with "MB 3 Al La Cold, Adhesive" at 1% - 2 gal /sq sealant with splice Se ant ", to eps is o ap Se pant �,fo3w tional ` Membrane: - 1 ply "APP 180 FR Cool" fully adhered with "MB Cold "QuickPrime "' or , "QuickPrime Plus i Adhesve" at 1 -�6i al /s` l g q Firestone EPDM membrane -assembly to j I 7. Deck: NC Incline: 1 QuickSeam product or SA -1065 Sphce A �, Insulation: Any UL Classified polyisocyanurate, perlite, fiberglass or that assembly.: y am, wood fiberboard, any combination, any thickness mechanically fastened As an alternate, crushed stone conforming', �I Base Sheet: 1 ply MB Base Sheet" or "SBS Base" or "SBS Poly Base" in lieu of river bottom stone at the sam, II; or "SBS Premium Base" mechanically fastened Accessory Products are acceptable for use Base" d 1 x Ply Sheet: 1 ply "SBS Bas or "SBS Poly Base" or "SBS Smooth" or As and alternate, a Firestone' Pav r - "SBS Premium Base" fully adhered.with "MB Cold Adhesive" at 1 - 2 ballast and-maintain the Classification of As an a ga / sq alternate, river bottom or crushed. ' No. 3 or 24 may be used in lieu of the No- 4' , j I I i Membrane: 1 ply "SBS" or "SBS Smooth" or "SBS Premium Cap" fully As an alternate, river bottom or crushed j adhered with "MB Cold Adhesive" at life - 2 gal /sq No. 1 or 2 may be used in lieu of the No. 4 s I, LOOK FOR THE UL,•MARK'ON PRODUCT