401 NE 95 St (5)/14
M S ��� BUILDING INSPECTION DEPARTMENT
/I 3.) -06 /4 cite
APPLICATION FOR BUILDING PERMIT
Application is hereby made for the npproyal of the detailed statement or the plans and specifications herewith submitted for the build •
ins or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
MIAMI SHORES VILLAGE
2 -29 -84
Date..._...._...._...__ _.._._._...__......_.__..._.... ,19.--
Owner's Name and Address Mr. John Cook _ No... —
N E treat
Registered Architect and /or Engineer ..... .........•,,,,,..,,,..,-,• „,•,
1401 NW 20 St. Miami 33142
Name and address of licensed contactor W. R. Robbins & Sons
Location and legal description of lot to be built on:
Lot Block Subdivision....
Street and Number where work is to be done 110 ..NE. 9E Sts.eat.,
State work to be done and purpose of building (by floors) _ Boof R – Gelnent s tj:ln„gletile
and for no other purpose.
New Building Remodeling Addition Repairs No. of Stories _
To be constructed of Kind of foundation Roof Covering
Estimated Total cost of improvements $ 600.00 Amount of Permit S. 20.00
Zone cubage required .Plan Cubage
Distance to next nearest building. Size of Building Lot
Maximum live load to be borne by each floor
I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may
be sent to.. W . R. Robbins & Sons 1401 NW 20 St. Miami 33142
The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer
of Labor under the Florida Workmen's Compensation Act, being Section 5066, Compiled General Laws of Florida, Perrnantnt Supplement,
and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him
in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice
or notices as arc required by the Act. The undersigned agrees to employ only such subcontractors on work • be performed under this
pcnnit, as are licensed by Miami, Shores Village.
Remarks (Signed)
STATE OF FLORIDA,
COUNTY OF DADE. f ss.
Before me, the undersigned authority, a notary public, duly authorizcd to administer oaths and take acknowledgments. personally ap-
peared
and who, being by me first duly sworn, upon oath deposes and says that he is the.
of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts
therein by him stated are true..
Permit No. /t Date j l/ " .� Read, Sworn to and Subscribed before me.
Disapproved Date
(Signed)
Notary Public, State of Florida
.. ► . '
Building Inspector My Commission Expires sass..
to me well known,
PLANNING BOARD DATE
Chairman Member
Member Member
Member Member
Council Approved Date Disapproved Date
NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from
the Pl.rnnl,, l:o.rrd.
A re inspection fee of 31.00 will be charged when such re- inspection is made necessary by Improper notice for inspection or faulty
materials and /or workmanship.
zara e Associates Inc.
Roofing Laboratory
Testing and Research
Moisture and Up —Lift Testing
RE.: TEST TO DETERMINE ROOF TILES ARE SECURED TO DECK AFTER 30
DAYS INSTALLATION - SOUTH FLORIDA BLDG. CODE 3404.3
Date: 9/ 29/ 95
Property address: 401 N.E. 95th. St., Miami Shores, Fl
Owner: Miami Shores Baptist Church
Contractor: Obenour Roofing
Permit #: 38009
City: Miami Shores
Type of Tile: Monier Vanguard Roll
Product Control #: 95- 0301.01
Roof Slope: 3/ 12
Sq.ft. area: 2,400 sq.ft. approx.
Testing Equipment: Chatillon - DFIS 100 - Calibrated 9/ 7/ 93
October 2, 1995
The purpose of this quality control test is to confirm that there exists sufficient
bonding by the mortar to the tile and underlayment in the tile system applied; it will be
determined whether 75% of the tile bonds to be tested in three different roof areas,
provides sufficient resistance to an arbitrary static uplift Toad applied on the tile. This
procedure will satisfy the Building Code Compliance requirements set forth in Protocol PA
106 -94.
Tiles have been tested on three different roof areas: field, perimeter and corner
areas. Prior to testing, dimensions of these areas were determined and recorded
according to Chapter 23 of South Florida Building Code.
Tiles selected at random from the three different areas, were lifted by hand, in
order to test for loose components.
LOAD APPLICATION: An arbitrary load of 35 Ibf. has been applied to each tile, holding
the load for 5 seconds. Test results are tabulated as follows:
2524 W. 3rd. Awenue, Hialeah, Florida 33010
(305)433 -14B4 (395)437 -2332 Fax (305)437 -2290
Pietro -Dade County Certification No. 94- 0125.0E
AREA
#
PULLS
LOOSE
TILES
BROKEN/
CRACKED
TILES
ADHESIVE
DELAMINATED
FROM
UNDERLAYMENT
TILES
DELAMINATED
FROM
ADHESIVE
Field
44
none
none
none
none
Perimeter
66
none
none
none
none
Corners
44
none
none
none
none
Enclosed find a sketch of the test site roof, indicating field, perimeter and corner
areas with dimensions, and also, location where pulls have been conducted.
Truly yours,
ZARA AND ASSOCIATES, INC.
TER L. SARA
Lab. Director
Encl. Sketch
More than 75% of the tile bonds tested in each of the three areas, provided
sufficient resistance to the arbitrary load applied.
More than 25% of the tile bonds tested in each of the three areas, did not
provide sufficient resistance to the arbitrary load applied.
More than 10% of the components have been determined to be "loose"
components.
The static uplift quality control test for the property in question, complies
with the Code requirements 3404.3 and Protocol PA 106 -94.
RICARDO . CARLES, P.E.
PROPERTY LOCATED AT 401 N. E. 95TH. ST. , MIAMI SHORES, FL
a
15.000 FTo
51. 000 FT
2 story
N
e Field
Perimeter
0 Corners
12. 000 FT
15.000 FT
N
18. 000 FT
13. 000 FT
20. 000 FT
NOTE:
PREVIOUS LOOSE TILES,
WERE FIXED, AND RE— TESTED.
FRONT
September 15, 1995
TO:
RE: Up -lift Tests
Yours truly,
ZARA AND ASSOCIATES, INC.
AiOU
ciela Zara
President
Zara ASSocinte5, Inc.
FROM: Graciela Zara
Zara and Associates, Inc.
Roofino Laboratory
Testing and Research
Moisture and Up -Lift Testing
Mr. Frank Lubien
Building Official
Miami Shores Village
MEMORANDUM
As per Protocol PA -106, this is to inform you that the up -lift test performed at the
following property has failed because of loose and /or broken tiles.
PROPERTY ADDRESS: 401 N.E. 95th. St., Miami Shores, Fl
CONTRACTOR: Obenour Roofing
OWNER: Miami Shores Baptist Church
PERMIT #: 38009
Once tiles are fixed, we will re -test tiles and if the test passes at that time, then a report
will be issued with a pass result.
1
Ricardo A /Cartes, P.E.
2524 W. 3rd. Avenue, Hialeah, Florida 33010
0305 ?433 -1434 (308 )437 -2332 Fax C305)437 -2296
iletra -Dade County Certification No. 94- 0125.08
.PEIMIT APPLICATION FOR MUNICIPALITIES OF DADE COUNTY
(OWNER TO RETAIN COPY)
Date 5 -15 -91 Job Address
Legal Description Master Permit #
Owner / Lessee / Tenant Gail R. Lanham - Miami Shores Baptist Church
Owner's Address 401 NE 95 Street
Contracting Co. Robbins Roofing Address
Qualifier William Robbins
State# 2754 Competency# RC0020296
Architect /Engineer
Bonding Company
Mortgagor
Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL PAVING FENCE SIGN
WORK DESCRIPTION
Square Ft.
Signatu
Date,'
,/
PERMIT FEE: APPROVED:
Zoning
Mechanical
2500
401 NE 95 Street
tear off, apply 1/30 tincap nailed, 1/90 with hot asphalt
lay new tile
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO
DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT).
Application is hereby made to obtain a permit to do work and installation as indicated above, and
on the attached addendum (if applicable). I certify that all work will be performed to meet the
standards of all laws regulating construction in this jurisdiction. I understand that separate
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING, and MECHANICAL work.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work
will be done in compliance with all applicable laws regulating construction and zoning.
Furthermore, I authorize the above -named contractor to do the work stated.
6/or Con o President
mss.
f
N ARY PUBLIC STAY FLORIDA.
Po7v CO %7G71SS101� �kP
E OF FL
flCPoDtD THRU NOYARV PUBLIC u Z 25. 1991.
Notary •sto Owner and /or Condo President
Comm Sion Expires:
* . * .,* * * * *
SS# 264 _56 _5877 Phone 325 -0880
Address
Address
Address
Estimated Cost 8000.00
Signature
Date:
No
My
*
Tax Folio
Phone 758 -.0559
1401 NW 20 Street •
Fire
Building
Plumbing Engineering
Ins.Co. Leader Ins.
i°
o:f. C:aiit r$nttiio2ta efi�l�i, uilder
My Cornrjon Expires Jan. 3, 1992
fended Thru Reg Tins. Co.
ary -s .o Contractor or Owner- Builder
Commission Expires:
* * * * *
Other rt66V- 5)1;f(50
Electrical
*
PERMIT # Tax Folio No.
NOTICE OF COMMENCEMENT
State of Florida
County of Dade
THE UNDERSIGNED hereby .gives notice that improvement will be made to certain real
property, and in accordance with Chapter 713, Florida Statutes, the following
information is provided in this Notice of Commencement.
1. Description of property: (legal description of the property and street address if
available) 2/v //2 5;, S"
?. General description of improvement:
3. Surety:
�o -terry Pub 1
b. Interest in property: C.) fr %o-/ (2
r' of
3. Owner information: me
a. Na and. Address: fj �%� f/ j/
Name and l
c. Name and address of fee simple titleholder(if other than owner):
6' /cam /O 4pry'/ 1.5 4%, /./
4. Contractor: (name and address) /).62 XQ o i /AY( / <0/ /L.)--Ze 2U S /A/ice -cr
a. Name and Address
b. Amount of bond$
J. Lender: (name and address)
7. Persons with the State of Florida designated by. Owner upon . whom notices or
other documents may be served as provided by Section 713.13(1)(a)7., Florida
Statutes: (name and address)
3. In addition to himself, Owner designates of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),
Florida Statutes.
7. Expiration date of notice of commencement (the expiration date is 1 year from
,the date of recording unless a different date is specified)
• Signature of
worn to and sub icf b b•af'ore /me this day of
NOTARY PUBLIC, STATE OF FLORIDA,
EIED M C IS I O p N EXPIRES: JUNE 25. 1991.
9LIC UNUERWRIil,.S.
My Commission Expires:
62 DODO
0 G:570 C:. ;0 G C3 Co a Ciao Fpy o iC,o
C 23 cJV;O3 c. _ 6 ,71 04
^ —A n A L 90
G�ao i doi CiGici:13 Ccoo.
, 1991.
•
S 't
Legal Description
Owner/Lessee / Tenan U inli 4 h01.0.0 eki
Owner's Address
Contracting Co.
Qualifier
WORK DESCRIPTION RS n • " ` — ' Or 1-#30
Square Ft.
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Job Address 40 / NE OLD Tax Folio 1 / - 3 2.0 G 0 / +- 0 (o 0
NJ
37o u11/LIV,2t'
6 Cali 6116ht,
eo 0 BO2rxiun
Signature of owner and/or Condo resident ' Dat
Nt /A1thi 5I4o!Ls 63 /Si C'HUficK
datta. 61 vtil(.A L1191 9S
Notary as to Owner and/or Condo President ate
My Commission Sires _, ; _ ,
Historically Designated: Yes
Address
Phone
1' S: PERMIT ( - RADON C.C.F. i 4
NOTARY
Building
_�,� 1a. ,9 L L
a
No
3�t
Master Permit #
Phone
93015 /t,E t'2 O$.
757 -26/2
Ins. Co. C X�¢C'1�P It ES / F
State # / 4 30 (r Municipal # i Competency #
Architect/Engineer Address
Bonding Company Address
Mortgagor Address
Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL( ROOFING) PAVING FENCE SIGN
rib (0
"
11911 � , �
,ovil a o +�►iearaP 6x a Lvl(�aJQ/
00 Estimated Cost (value) J 025 .00
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.)
Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I
certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliances, ith all applicable
laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated.
ure of Contractor or Owner - Builder
Notary as to Contractor or.O der- Builder
My Commission Expires:' (;.,T7.17.
Date
TOTAL DUE
s
IC ate
APPROVED:
Zoning
Mechanical Plumbing Engineering
Electrical
Interest in property
OY
2. Description of improvement:
4. Contractor's name and address
Signature of Owner CARL 4, (tq
Notary Public
12101-112 7/94 PAGE 3
S ArE OF r2 LORIDAo COUNv OF DADE�E
I fieiliIOYCEM2Y Qh.o Ai.
Is a 4ruo copy off ea di
or9Jl cl 6lIc 11\'n A —
T E S d e " uo1 Soul.
WITNESS h'"
cavity Couztz
Ailo " ----„
' NOTICE OF COMMENCEMENT
A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION
PERMIT NO. TAX FOLIO NO.- /I-3206-014.0600
STATE OF FLORIDA
COUNTY OF DADE
THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance
with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement.
1. Legal description of property and street address 40 / Ner 95-M .'
3. Owner(s) name and address: 3 76
Mtetm- . 4344 Ottca.et - 0L2,0 /y1eby�
OGtMRA Q
Name and address of fee simple titleholder:
(13;.6 Put. "Q, &?
5. Surety: (Payment bond required by owner from contractor, if any)
Name and address:
Amount of bond: $
6. Lender's name and address:
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served
as provided by Section 713.13(1)(a)7., Florida Statutes.
Name and address:
8. In addition to himself, Owner designates the followi g person(s) to receive a copy of the Lienor's Notice as pro-
vided in Section 713.13(1)(b), Florida Statutes.
Name and address:
9. Expiration date of this Notice of Commencement (thl expiration date is 1 year from the date of recording unless
a different date in specified)
Print Owner's Name M /AM1 5' I-4oRES BAPTIS i c%Iu/ZCH
Sworn to and subscribed before me this l9 day of L, 19 95
Print Notary's Name SRNDQ4 Q We/you E.
My Commission Expir s• OFFICIAL NOTARY SEAL
CAAlil1?A it nnr�rnrrn
NOTARY PUBLIC STATE OF FLORIDA
COMMISSION NO. CC265272
MY CaiMISSION EXP. MAR. 1Z1997
95824 -5323 1995 JUN 21 12:52
Prepared byK21.41411 ArtI h
Address' 46 Th2e1146 .�
r 3.3 al
12a01 -158
Job Address: 1 761 tiE l
1. General
APPENDIX 'E°
METRO -DADE UNIFORM BUILDING PERMIT
SECTION II
MORTAR OR ADIIESIVE SET TILE SYSTEMS
Contractor:
The information provided in this Section is required to confirm
Product Control Approval of the proposed tile system assembly;
confirm compliance with the wind load requirements of Chapter 23
of the South Florida Building Code (SFBC); and confirm compliance
with Sections 3403.5 and 3404 of the South Florida Building Code.
2. Documentation
The following documents are required for submission with the
Uniform Building Permit application:
► Two (2) copies of the proposed tile system assembly's and
associated roofing component's Product Control
Approval(s).
► One (1) copy of the tile system assembly and/or roofing
component(s) manufacturer's published application
instructions and literature.
► All documents attached herein, filled out and completed in
full.
3. Project Information
Check one of the following:
O /New Construction
[17' Re -Roof
No)e: Mortar or adhesive set tile systems are not acceptable as recover
applications.
pert
Mortar or Adhesive Set Tile Systems
Page - 1
Roof Pitch (fill in):
5 " : 12"
ft
no
Process No.
Is the deck solid sh . thed? (circle 'yes' or 'no')
no
Deck Type (check one of the following):
O Nominal '/2" Plywood (for re -roof only)
O Nominal ' /," Piywood
®Wood Plank
O Other (fill in)
Note: Mortar or adhesive set tile systems shall not be installed at a pitch
greater than 7'/2 ":12 ". Mortar or adhesive set tile applied at a
pitch greater than 5 ":12" and less than or equal to 7 " :12" shall
have the first thrcc courses of tilt nailed with not less than one
nail per tile. As an alternate, the first three courses of tile may be
applied in mortar over a single layer of minimum 12 ga. wire
mesh with square openings of not less than '/ which is
mechanically attached to the sheathing with not less than one nail
Circle 'yes' or 'no' for each of the following:
Have you attached two copies of the tile system manufacturer's
Product Control A 'val for the proposed tile system?
no
Have you attached a copy of the tile system assembly and/or
roofing component(s) manufacturer's published, application
instructions and oth literature
C� no
Is the proposed underlayment approved for use with this tile
system assembly
Job Address:
y eiIJEq kt
Project Information (continued):
Contractor:
If the proposed undcrlayment is self - adhered, have you complied
with the venting requirements of Section 2913.3 (b), (c) and (d) of
the South Florida Building Code?
yes no
Are all • related accessories approved for use with this tile system
assembly?
Tile:
Tile Name:
Manufacturer:
Tile Material:
❑/ Clay
(J Concrete
❑ Other:
no
Are the proposed edge metal attachment fasteners in compliance
with the requirements of the South Florida Building Code (minimum
12 ga. annular ring shank, corrossion reisistant nails)?
no
4. The Tile System Assembly:
The following information is required to confirm compliance with
Subsections 3403.5(a) and (c) and Section 3404 of the South Florida
Building Code.
va d te
Product Control Approval Number: 95. 0307 - 0 /
Mortar or Adhesive:
Check one of the following which apply to the proposed tile
securement for use with the proposed tile system assembly:
Mortar or Adhesive Set Tile Systems
Page - 2
Net wk. 14 41
Check one of the following which apply to the proposed tile
fasteners (for the first three courses) for use with the proposed tile
system assembly:
Tile Fasteners (for first three courses if roof pitch exceeds 5 ":12"
and is less than or equal to 7":12"1:
[ Mortar: Manufacturer:
Mixing Ratio:
❑ Adhesive: Type:
Manufacturer:
❑ Minimum 12 ga. galvanized roofing nail:
/N /A
Length:
❑ Other: Type:
Length:
Process No.
44etAlu ‘1_46a :362, .�•re e�
11a� rb 5 c
N /A
"
Note: All tiles shall be installed in compliance with the provisions set
forth in the tile system assembly manufacturer's Product Control
Approval and the minimum requirements set forth in Subsections
3403.5(c) and 3404.2 of the South Florida Building Code. Tile
fasteners in the first three courses (if applicible) shall be of
sufficient length to penetrate the sheathing a minimum of 1" or
through the sheathing thickness a minimum of '4 whichever is
less.
Underlayment:
The following information is required to confirm compliance with
Section 3403.5(b) of the South Florida Building Code.
Job Address: / titer 54 Contractor: P/1
The undersigned certifies that the Mortar or Adhesive Set Tile System
Assembly is in compliance with the plans, specifications, and details
submitted by the architect.
STATE OF FLORIDA - COUNTY OF DADE
Before me this day personally appeared Ji4h'I<S Q geiv01IL
who, being first duly sworn, deposes and says that all information submitted
herein is true and correct.
a0
used Contractor / Owner
Signature
Sworn to and subscribed before me this th day of `
I99(.
My commission expires: I NSTA= L' T� == r 4 >z
MY C0%41\fi- c...,.l a
Notary Public
State of Florida
Mortar or Adhesive Set Tile Systems
Page - 8
Process No.
Job Address:
Contractor:
Mortar or Adhesive Set Tile Systems
Page - 7
\
2. 6
to
23
1 r
9,
Sketch Roof Plan, indicating all dimensions, slopes and any roof top equipment.
Also insert variable labeled "a" which represents perimeter and corner dimensions
per Chapter 23 of the South Florida Building Code.
(See ASCE 7 -88 Fact Sheet Attached )
1g
BUILDING INFORMATION #2: Roof Plan with Perimeter and Corner Dimensions
Job Site Identification:
Process No.
Job Address: 401 & - cothcr
Contractor:
Ridge Height: vekleight: R 4�'`'4�ean Height
feet / feet /J. feet
Insert Building Ridge Height, Eave Height and Roof Mean Height.
Also inscrt applicable information pertaining to the building below.
(See ASCE 7 -88 Fact Sheet Attached )
Exposurc Category: 1...
Classification Category:
At I lurricancc Occanlinc7: Y / N
Basic Wind Specd at
Building Location 110 mph
Building Condition based on
% of openings: A
(See Table 9 ofASCE 7 -88)
Ground Level
BUILDING INFORMATION #1
Job Site Identification:
Mortar or Adhesive Set Tile Systems
Page - 6
Process No.
Job Address: / Lr t?st .L
Contractor:
Ridge Venting:
(1/ applicable )
N�
Deck:
Type:
Thickness: -- '`
Underlayment: &3o # 9
/
Fastener: nt 7 0 r ,
ner. '�/
5"
12"
FILL IN APPLICABLE ROOFING COMPONENTS WI IICI I MAKE UP
TILE SYSTEM ASSEMBLY. INSERT ANY ADDITIONAL LEADERS
INDICATING ADDITIONAL ROOFING COMPONENTS NOT SHOWN
ON TI-IIS PAGE. ( Where Roofing Component not used in Tile System
Assembly, fill in with "N /A ".)
Roof Pitch
Head Lap Dimension: '3
(minimum 1' unless otherwise specified
in the the system assemblyProduci Control
Approva
Mortar /Adhesive:
Tile: Qpa
Tile Fastener:
Edge Metal w CyNler,„
Fastener: / ,�
r. /J�f f/
Bird Stop: A/
(tfapplicable)
Edge Metal 4, a
or Guncr: y um)" •
Existing or Proposed Ac t
Soffit Venting:
DETAIL #1
Job Site Identification:
Mortar or Adhesive Set Tile Systems
Page - 5
Process No.
Job Address: I/0 / SUE 9 j
Underlayment (continued):
Check all of the following which apply to the proposed underlayment
for use with the proposed tile system assembly:
ASTM #30 asphalt saturated felt with:
Manufacturer: TAM CO
❑ ASTM #15 asphalt saturated felt with:
Manufacturer: h)/4
((Mineral Surfaced Roll Roofing with:
Manufacturer: TAM C. D
❑ Other:
Type:
Manufacturer:
Underlayment Fasteners (if applicable):
[Other:
Type: 614 iv
Length: 1'14 "
Manufacturer: 1)' C k 5 I+'
Contractor:
O 19" overlap
❑ 6" overlap
0 4" overlap
QV 2' over 14 p
O 19" overlap
❑ 6" overlap
O 4" overlap
O 19" overlap
❑ 6" overlap
❑ 4" overlap
a 3" ever
Check one of the following which apply to the proposed
underlayment attachment:
❑ Minimum 12 ga. electro- galvanized roofing nail with
minimum 32 ga. x 1'/ tin cap:
Length:
Manufacturer: '
Mortar or Adhesive Set Tile Systems
Page -3
Spacing (per tile system assembly Product Control Approval):
Field: 12 " o.c.
/
Laps: /4 " o.c.
5. Related Accessories:
Process No.
Edge Metal (refer to Section 3408.2 of the South Florida Building
Code):
Type: 4)v� ,Mi j
5)4 3
Dimensions:
Gauge or Thickness: 2 !
Finish: Clf A)
Note: All edge metal shall be nailed on the flange and nailed or clipped
at the face in compliance with the provisions set forth in Dade
County Protocol PA 111, marked Appendix 'U' in the South
Florida Building Code.
Adhesives (check one of the following):
❑ Cold Adhesive:
Type:
Manufacturer:
GI
Flashing Cement:
Type:
Manufacturer:
N /
Teo/will)
Job Address: 4 /v " 9.5 Contractor:
Adhesives (continued):
Note: Application of adhesives shall be in compliance with the Roofing
Component Product Control Approval and the minimum
requirements set forth in Subsection 3403.5(e)(4)(cc) of the South
Florida Building Code.
Ventilation System (check one or more of the following):
The following information is required to confirm compliance with
Subsection 3401.4(e) of the South Florida Building Code.
0 Ridge: Type Size in=
Eioffit: Type C6 hlI Size in
Note: If underlayment is comprised of a self - adhered membrane, both soffit
and ridge ventilation systems are required, unless a base sheet is
applied as an anchor sheet below the self - adhered underlayment.
Note: The Tile System Assembly shall be installed in strict compliance
with the application instructions enumerated in the Product
Control Approval. A permit shall be issued for application of the
specified Tile System Assembly only. Any change to the specified
Tile System Assembly shall require submission of a revised
SECTION II with a copy of SECTION I, noting the permit
number issued.
Mortar or Adhesive Set Tile Systems
Page -4
Additional Notes:
Process No.
• . Ml�uno>±
Monier Roof Tile •
1900 Northwest 2 I st Avenue
Port Lauderdale, FL 33111
1'ltonucr NO. :
ACCEPTANCE NO.:
EXPIRES:
APPROVED:
METROPOLITAN DADE COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
acmga COta13aj■tnarry nr APY'[i E]' E
Raul Rodriguez
Product Control Division
Supervisor
- PLEASE NOTE
nits 1S TIIE COVERSIitET. Sri: ADDITIONAL, PACES FOR SPECIFIC AND GENERAL
CONDITIONS.
BUILDING CODE COMMITTEE
pries anger. 1'.I',.. Director
Building Code Compliance l)cparlment
Metropolitan Dade County
(WILDING CODE COMPLIANCE DEPAnTMENT
SUITE 1003
• ' METRO.DADE F J'GLEf WILDING
140 WEST FLAMED STIIEET
MIAMI, FLOf1DA 90190.1663
(305) 975.290
FAX (305) 376-2000
u e �
it u if
Your application for Product Approval of
ooting_T'tk under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and
Types of Construction, and completely described in the plans, specifications and calculations as submitted by
Rcdland Technologies, The Center for Applied Engineering, Inc. and Professional Service Industries, Inc. has
been recommended for acceptance by the Building Codc Compliance Department to be used in Dade County,
Florida under the specific and standard conditions 5ct forth herein.
The approval shall be valid for a period of three years. 'Mc Building Code Compliance Department reserves the
right to secure a product or material at any time I'or a jobsite or manufacturer plant for quality control testing. If
product or material fail to rgrform in the approved manner, the Code Compliance Department may revoke, modify
or suspend the use of such product or material immediately. The Building Code Compliance Department reserves
the right to require testing of this product or material should any amendments to the South Florida Building Codc be
enacted affecting this product or material.
The expense of such testing will be incurred by the Manufacturer.
This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code
Compliance Department and approved by the Building Code Committee to be used in Dade Cot , Florida under
the conditions set forth above.
M.R1O1995
06 -20 -95 08:31 BIELER ROOFING
Ultra=
Monier Roof Tile
1900 Northwest 21st Avenue
Fort Lauderdale, FL 33111
PRODUCT CONTROL NOTICE OP ACCEPTANCE
ROOFING SYSTEM APPROVAL
i : Prepared Roofing
Tile
T Nail -on /Mortar Set/Adhesive Set
Stth -Type: 'Concrete
csc
Product Control No.: 95A301.01
Approval Date: 2ALLILI95.5
Expiration Date: • r " ofe_ }__ 49
Monier Roof Tile is n member of the Redland Group, a world wide producer of primary building
products and roof tile, Monier manufacturers concrete roof tile for nail -on, mortar set or adhesive set
applications in plants throughout the United States ranging from Washington State to Florida. All tile is
manufactured from extruded concrete consistin of Portland Cement, plasticizer, iron and metallic
oxides, and blended aggregates. ' t ► r
RcfcriQ anatardjalatgaretranittAPIZMILELQIIICr tile profiles.
Monier sells tile systems through local distribution and directly to consumers, All profiles have
matching trite pieces used for rake hip, ridge hip, and valley terminations. Tile system accessories such
as undcrlaymcnt, ventilation systems and flashing systems are also available. These accessories arc
manufactured for all profiles and form a part of this Product Control Approval.
Monier's "Roll" roof till has been tcstcd in compliance with the South Florida Building Code
requirements for concrete, nail -on, mortar set and adhesive set tilt applications. The minimum roof
slope for Monier's "Roll" nail -on, mortar set or adhesive set tiles shall be 2 ":l2 ". Sec the "Profile
Drawing" section in this Approval for the "Roll" profile drawing, The Monier "Roll" tilt profile has
been tested for both wind characteristics and static uplift performance, therefore, any consideration for
installation shall be done as a 'Moment Based System'. Data for attachment calculations is noted in
Tables 1 through 4 of this Approval.
Contact:
Reese 1-1. Moody
Technical Service Accessories Manager
1900 NW. 21st Avenue
Ft, Lauderdale, FL 3331 1
(800) 432 -2715
,7
Raul Rodriguez
ID =305 651 9293
P.02
06 -20 -95 08:32 BIELER ROOFING
Trim Pieces
TRADE NAMES OF PRODUCT'S MANUFACTURED OR
LABELED BY ArrUc,tr r
Test
J't odu;t Diumatians Siesifiratians
Monier Roll Tile 1- 16 PA 112
w 13"
t /�" th ick
1= vanes
w : varies
varying thickness
PA 112
Raul Rodriguez
ID =305 651 9293 P.03
Product Control No.: 95- 0301•QL
Product
Description
Low profile, interlocking, high
pressure extruded concrete roof tile
equipped with.two nail holes and
double roll ribs.' For direct deck'or
battened nail -on, mortar or adhesive set
applications.
Accessory trim, concrete roof pieces
for use at hips, rakes, ridges and valley
terminations. Manufactured for each
tile profile.
'.06 -20 -95 08:33 BIELER ROOFING
Product
1130 Pelt
1143 Coated Base
Sheet
Mineral Surface Cap
Sheet
Rainproof 11
lee and Water Shield
Mopping Asphalt
Flashing Cement
TRADE NAMES OP PRODUCTS MANUFACTURED OTHERS
Dimensiong
N/A
N/A
N/A
Lenzingtex -Z13 140 59" x 164' roll
Undcrlaytnent 22 Ibs/roll
30" x 75' roll
36" x 75' roll
or
60" x 75' roll
36" x 75' roll
N/A
N/A
Test
apecifcatians
ASTM D 226
type 11
Product
Saturated organic felt
to be ns a nailed
anchor sheet.
ASTM D 2626 Saturated and coaled
organic base sheet for
single or double ply
underlayment.
ID =305 651 9283 P.04
ASTM D 249 Mineral surfaced
asphalt roll roofing
for use as a top ply in
a double ply
undcrinyment system.
PA 104 Single ply, nail -on
undcrinyment.
M 104
ASTM D 312
type IIlorIV
ASTM D 4586
Product Control No.:
Single ply, nail -on
undcrlayment with 2"
self - adhering top.
edge.
Cut back, asphalt
based, asbestos free,
fiber reinforced,
trowel grade cement
for repair and flashing
applications.
Mallmfularcz
generic
generic
generic
Lenzing
Performance, Inc.
PCA 1194.0527,05
Protect -O -Wrap, Inc.
PCA 1194.0714,01
PA 103 Self - adhering W.R. Grace Co.
undcrlayment for use PCA 1192-1116.01
as a top ply in two
ply undcrlayment
system wild
Approved 1130 or 1143
as the base layer.
Asphalt for bonding a generic
mineral surface cap to
a mech. attached base
sheet in a double ply
undcrlayment system.
generic
Test Product
Product DJmensiojtl Spertflentinns p escrtpOgg Manufacturer
Asphalt Primer N/A ASTM D 41 Cut back, asphalt generic
based coating used to
facilitate bonding of
dissimilar materials.
Roofing Nails ' min. 12 ga. with PA 114
'4" head Appendix
Tin Caps
Wood Battens
Tile Nails
Tile Screws
Roof Tile Mortar
( "Tile f iteTM ")
min. 32 ga.
min. 1' /," o.d.
max. 2" o.d.
YeLlikttl
min, 1" x 4"
hojj7ontal
min. I" x 4" for use
with vertical battens
or
thin. 1" x 2" for use
alone
min. 8d x 2W or
min. 10d x 3"
min. 118 x 2W or
min. 1110 x 2"
PA 114
Appendix 13 '
Wood Preservers
Institute LP - 2
PA 114
Appendix Ir
PA 114
Appendix E
Roof Tile Mortar NIA PA,123
( "Quikretcdfl Roof
Tile Mortar 1111401
Product Control No.: 95 0301.01
Annular ring shank,
hot dipped, elettfa, or
mechanically galv.
roofing nails for use
in underlayment
attachment.
Corrosion resistant
circular disc for use in
underlayment
attachment
Salt pressure treated
or decay resistant
lumber battens
Corrosion resistant,
screw or smooth
shank nails.
Corrosion resistant,
coaled, coarse thread
WOOd screws.
gcncric
generic
generic
generic
generic
NIA PA 123 Prepared mortar mix Bermuda Roof
designed for mortar Company. Inc.
set roof tile PCA H94- 0614.01
applications. .
Prepared mortar mix Quikrete Constructio
designed for mortar Products
set roof tile PCA 1194- 0808,01
applications.
4 17/11
06-20-96 06:33 BIELER ROOFING
C
r
ID =305 651 9293 P.05
Product Control No,: 95 -030 1 A 1
Test Product
Product Dimensions SitSSifiri3tiW118
12otriptioli Manufacturer,
Roof Tile Mortar N/A PA 123 Prepared mortar mix W.R. Bonsai Co.
( "3ONSAL® Roof designed for mortar I'CA 1194 - 0628.03
Tile Mortar Mix ") set roof tilt
applications.
Roof Tile Adhesive ' . N/A Scc PCA Two component , Polyfoam Products,
( "Polypro® AM 60 ") polyurethane adhesive Inc.
designed for adhesive PCA 1194- 0401,01
set• roof tile
applications.
Hurricane Clip & Clio PA 114 Corrosion resistant
Fasteners min.'' 'A" width Appendix E . bronze, aluminum,
min. 0.060" thick stainless steel,
galvanized steel or
1 rastonexs plastic attachment
min. 8d x 1V." clips for supplemental
tile attachment. Clips
are installed with
corrosion resistant
roofing nails
compatible with the
clip. A hurricane clip
is required on all
nail -on cave tiles,
generic
Valley Flashing min. 26 ga. ASTM A 525 Galvanized steel generic
min. 16" width valley flashing ,
Drip Edge min, 26 ga. PA 11 I Galvanized steel drip generic
,min. 2" face flange edge
min. 2" deck flange
' estAgenccy
Rcdland Tcchnologics
Redlnnd Tcchnologics
The Center for Applied
Engineering, Inc.
The Center for Applied
Enigneering, inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Redlnnd Tcchnologics
Redlnnd Technologies
Redlnnd Tcchnologics
Rcdland Technologies
TEST REPORTS
Tcsk. cr
7161.03
Appendix III
7161 -03
Appendix 111
94 -084 •
94.06013
25- 7094 -I
25- 7094.7
25- 7094 -4
7161 -03
Appendix 11
Letter Dated Aug. 1, 1994
P0631-01
PO402
Product Control No.: 95.0301.01
Test Nam/Rout
Static Uplift Testing
PA 102
Static Uplift Testing
PA 102(A) , ..
Static Uplift Tesltng
PA 101
(Mortar Set)
Static Uplift Testing
PA 101
(Adhesive Set)
Static Uplift Testing
PA 102
(4" Headlap, Nails, Direct
Deck, New Construction)
Static Uplift Testing
M 102
(4" I lcadlap, Nails, Battens)
Static Uplift Testing
PA 102
(4" 1 -Ieadlap, Nails, Direct
Deck, Recover /Iteroof)
Raul Rodriguez
Wind Tunnel Testing
PA 108
(Nail -On)
Wind Tunnel Testing
PA 108
(Nail -On)
Wind Tunnel Testing
PA 108
(Mortar Set)
Withdrawal Resistance
Testing of screw vs: smooth
shank nails
Qatc
Dec. 1991
Dec. 1991
May 1994
March, 1994
Oct. 1994
Oct. 1994
Oct. 1994
Dec. 199I
Aug. 1994
July 1994
Sept. 1993
1
06 -20 -95 09:49 BIELER ROOFING
c
x UM%
The Center for Applied
Engineering, Inc.
Professional Service
Industries, Inc.
Project No. 307025
Test IIMDC -7
224 -47099
ID =305 651 J'LJ;3
Product Control No.:
IsiLk
Wind Driven Rein
PA 100
Physical Properties
PA 112,
Raul Rodriguez
ILZLc
Oct. 1994
Sept. 1994
06 -20 -95 08:37
Dccic Type:
Deck Description:
SYSTEM D:
Slope Range:
Undcrlalymcnt:
Roofing Tilc:
Comments:
BIELER ROOFING
SYSTEMS
(Cor mNUED)
I0 =305 651 9293 P.09
Product Control No.• 95-4312L0.1--
Wood, Non - insulated
Ncw construction " / „” or greater plywood or wood plank.
Mortar or Adhesive Set Application
2 ":12" to 7 " :12"
Note: System D is only acceptable In this slope range. For slopes in excess
of 7 ":12 ", refer to System C.
Install choice of Approved undcrlayment system, noted on Page 1 of Dade
County Protocol PA 120, in compliance with Section 3.02 of PA 120. See
System Limitation 117.
Install tile in compliance with PA 120 using an Approved mortar or adhesivo.
Mortar or adhesive shall be applied in compliance with the mortar or adhesive
manufacturer's Rooting Component Product Control Approval. The mortar or
adhesive attachment shall provide sufficient attachment resistance expressed as
a moment to meet or exceed the required moment and adhesive s ve determined
di in
compliance with PA 115 or PA 127. The mortar
is noted in Table 4, attached.
1. For re -roof applications, 13 / plywood is an acceptable substrate.
2. For mortar set applications, the first three courses of tile shall be nailed with
not less than one nail per tile. As an alternate, the first three courses of tile
shall be applied in mortar over n single layer of minimum 12 ga. wirc mesh
with square openings of not less than '1," which is mechanically attached to the
deck with not less than one roofing nail every 1 ft'. For roof pitches from
6 " :12" to 7 ":12 ", every third tile of every fifth course, beginning at the eighth
course, shall be nailed with not less than one nail per tile.
11
Rnul Rodriguez
06 -20 -95 08:37 BIELER ROOFING
SYSTEM LIMITATIONS
1. The standard minimum roof pitch for Monier "Roll ", nail -oil, mortar or adhesive set tile
applications is 2" rise in 12" run (2 " :12 "). The maximum roof pitch for mortar or adhesive set tile
applications is 7" rise in 12" run (7 ":12 ").
2. All nail -on tile applications having a roof pitch less than 4 ":12" shall be installed over both vertical
and horizontal battens ("Counter-Battens"), as noted in System A. Allnail -on tile applications
having a roof pitch in excess of 7 " :12" shall be installed over horizontal battens as noted in System
C.
3. For nail -on applications, brass or stainless fel screws
holes o t 1 mechanical hilnical attachment of tiles shall '
have a head diam:rtcr larger than that of the preformed
4. System installation shall be in compliance with the system specifications outlined in this Product
Control Approval. Nail -on tile shall be attached using one of the methods of attachment noted in
Table 3 of this Approval. Mortar or adhesive set tile shall be attached using an Approved mortar
or adhesive, the data of which is noted in Table 4 of this Approval. T c method of attachment
utilized shall provide sufficient attachment resistance expressed as a moment to meet or exceed the
required ntoment.of resistance determined in compliance with Dade County Protocol PA 115 or PA
127.
5. For nail -on tile applications, an cave clip is required on all cave tile. For mortar set applications,
the first three courses of tile shall be nailed with not less than one nail per tile. As an alternate, the
first three courses of rile shall be applied in mortar over n single layer of minimum 12 ga. wire mesh
with square openings of not less than 3 4I which is mechanically attached to the deck with not less
than one roofing nail every 1 IV. For roof pitches from 6 ":12" to 7 ":12 ", every third tile of every
fifth course, beginning at the eighth course, shall be nailed with not less than one nail per tile.
6, For mortar or adhesive set tile applications, a field static uplift test by a ae C u nt l than rc accredited
t agency, in compliance with Dade County Protocol 1 A 106, shall be required
days after mortar set applications and not less then 72 hours after adhesive set applications to
confirm tile adhesion, The results of this testing shall be reported to the Building Official and the
installer stating that the application has passed or failed PA 106 testing. lithe application fails PA
106 testing, the report shall state which portion of the test was failed;
Category 1 (examination for
loose tile) or Category 2 (uplift testing of tile). Subsequent to testing, the installer may repair not
more than 5% of field arca tiles and 10% of perimeter arca (i.c. ridge /rake) tile with Approved tile
adhesive. The installer shall place no identifiable marking on each repaired tile for future reference.
Any PA 106 re-test shall not include any marked tile.
7. For mortar or adhesive set tile applications, 30/90 hot mopped underlaymcnt applications may be
installed perpendicular to the roof pitch prior to hone 1,
1995 unless stated otherwise by the material
manufacturer. Thereafter, 30/90 underlaymcnt systems shall be installed parallel to the roof pitch in
compliance with Appendix'A' of Dade County Protocol PA 120.
12
ID =305 651 9293
Product Control No.:
LAVA(2
P.10