275 NE 94 St (7)•
BUILDING INSPECTION DEPARTMENT
APPLICATION FOR BUILDING PERMIT
Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build-
ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
Date ✓ 3- $ , 19..6.3
Owner's Name and Address /
- - - -- No. -- - -1 -5 Street 1 l 5 - e . - - --- -- '`/ - - - -$T_ .
Registered Architect and /or Engineer
Name and address of licensed contractor ,/_ L 6: 5
Location and legal description of lot to be built on:
Lot Block Subdivision..._._
Street and Number where work is to be done
State work to be done and purpose of building (by floors)
r-?. ' E - = ` 4 SA z` S
New Building Remodeling Addition Repairs
Disapproved _
( Signed) • -
o�g
MIAMI SHORES VILLAGE
te.
Building Ins. , tor
co, v,„(7-,
d
To be constructed of Kind of foundation
Estimated Total cost of improvements $ 7& " Amount of Permit $
Zone cubage required Plan Cubage
Distance to next nearest building Size of Building Lot
Maximum live load to be borne by each floor
I hereby submit all the plans and specifications for said building.
be sent to
All notices with reference to the building and its construction may
The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer
of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement,
and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him
in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice
or notices as are required by the Act. The undersigned agrees to employ only such subcontra tors, on ork rformed under this
permit, as are licensed by Miami Shores Village.
Remarks (Signe
RooLCoy5ring ....
_
STATE OF FLORIDA, j
COUNTY OF DADE. ss.
Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap-
peared
to me well known,
and who, being by me first duly sworn, upon oath deposes and says that he is the
of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts
therein by him stated are true.
Permit No _ Date 1
Read, Sworn to and Subscribed before me.
NNING BOARD DATE
;
and for no other purpose.
No. of Stories
Notary Public, State of Florida
My Commission Expires
Chairman / Member
Member Member
Member ...._ _. Member
Council Approved Date Disapproved Date
NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from
the Planning Board.
A re- inspection fee of 51.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty
materials and /or workmanship.
BUILDING
ELECTRICAL
PLUMBING
ROOFING
Owner of
Building
Contractor
or Builder
Legal Lot ,/
Description (/
Address of
Building
n
MIAMI SHORES VILLAGE, FLORIDA
DATE ✓ '`-'' 1954_
Contractor's
License No
Work to be performed under this Permit
PERMIT 110 11532
9
•
B 17
f
Br
Subdi-
vision
Value of
� '~ ,,. Project $ ,. � /
Signed
,f ./4"""5
t:'I
Amt. of
Permit
$
This permit is granted to the contractor or builder named above to construct the building to install the equipment or device described in the application
herefor in strict compliance with all ordinances pertaining thereto and with the understanding t at the work will be performed in compliance with any plans,
drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any
time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is
granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations
pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes responsibility for work
done by his agents, servants or employees.
In consideration of the issuance to me of this permit I agree to perform the w k covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or s cifications submitted to the proper authoritig¢'of Mimi Shores Village.
In accepting this permit I assume responsibility for all work done by either, my , my agent, servant or employee.
• PERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Date 9 -8 -94 Job Address 275 N.E. 94 Street Tax Folio
Legal Description
r�w n er Lessee / Tenant Ted Neveiler
Owner's Address 275 N.E. 94 Street
Contracting Co. QUALITY ROOFING CONTRACTOR, INC. Address 251 N.W. 99th STREET
Qualifier CARLOS AROCHO
State 1 RC0058627 Municipal #2078269 Competency # 17889 Ins.Co.
Architect /Engineer Address
Bonding Company Address
Mortgagor Address
Permit Type(circle one): BUILDING ELECTRICAL PLUMBING MECHANICALFING PAVING FENCE SIGN
Square Ft.
or Condo Pre id
Signatu
Date:
Notary as t. Owner and
My Commission Expir 44r7 MARYLOJ HERNANDEZ
., (. MY COMMISSION # CC 324212
. 's .�0.= EXPIRES: October 10, 1997
/ Bonded Thru Notary Public Underwriters
** * * * �,.. t . t _
FEES: PERMIT - RADON
APPROVED:
er and /or Condo President
Notary as t
My Commissi
* *
C.C.F. NOTARY
Fire
Master Permit #
Phone 754 -0200
Phone ( 305) 751 -0382
WORK DESCRIPTION Tear off flat deck roof to wood deck, install 1/2 inch insulation
board, install base sheet felt, mop on with hot asphalt 2 layers of
fiberglass felt install metal eave drip and paint roof with auniform
coating of aluminum roof paint.
3 00 Estimated Cost(value) $ 1,000.00
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO
SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR
NOTICE OF COMMENCEMENT).
Application is hereby made to obtain a permit to do work and installation as indicated above, and
on the attached addendum (if applicable). I certify that all work will be performed to meet the
standards of all laws regulating construction in this jurisdiction. I understand that separate
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I
au , ize t. e above -named contractor to do the work stated.
Signature of Contractor o Owner- Builder
Date:
_ _ r ekritCOMMISSION # CC 324212
EXPIRES: October 10, 1997
F, p d ` Bonded Thru Notary Public Underwriters
.1.,
*
*
Zoning Buildin L Electrical
Mechanical Plumbing Engineerin
*
*
der
**
TOTAL DUE ,$
Other
r
, Job Address: 2a /u . r_ / ST Contractor
GENERAL:
Type of Roof System Assembly to be Applied:
Manufacturer of Roof System Assembly:
Product Control Approval Number:
System Number from Product Control Approval:
(Attach a copy of the Roof System Assembly Product Control Approval and the Manufacturer's System
Guide Specification. )
( Note: If a minimum roof system is to be applied, describe all
components within the system and list the manufacturer of
each component. DO NOT complete this section if system is
Product Control Approved. )
Base Sheet:
Fasteners:
APPENDIX 'E'
Process No.
METRO -DADE UNIFORM BUILDING PERMIT
SECTION II
BUILT -UP APPLICATIONS AND
MODIFIED BITUMEN SYSTEMS
S ( Ropt:r1
CS Oe A .uc�sCo
0323 .3
/ M s -9-1A)
Ply Sheet(s):
Cap Sheet:
Asphalt:
( Note: No insulation system is acceptable under the minimum
roof category. )
Complete the following for all Roof System Assemblies:
Built -Up Applications and Modified Bitumen Systems
Pane -1
, Job Address: Contractor Process No.
(Check one of the following)
Recover Re -roof: V New Construction
If a recover, is the existing Roof System Assembly
to be used as a bonding substrate ?:
If YES, has an ASTM E907 test been carried out
to confirm adhesion of the existing membrane to
the substrate ?:
(If yes', attach ASTM E907 test report. )
Proposed Fastener:
(Attach withdrmval resistance test report. )
Has the deck been examined for moisture ?:
(Provide data confirming compliance with
Section 3401.9(c) . )
THE SYSTEM:
All Roof System Assemblies in the Product Approval have a variety of options. Briefly
describe the Roofing Components to be used in the Roof System Assembly and attach a copy of
the manufacturer's published specification:
Deck:
(Briefly describe )
Insulation:
(Type, size and method of attachment,
if applicable )
w
i/2. fur e,
Base Sheet or Ply: Al I W ea �� j rc
(Type and method of attachment )
lots or 6-As f3 c SG
Ply Sheet(s):
( Type and method of attachment )
Built -Up Applications and Modified Bitumen Systems
Page-2
Y N i( 0
Y N /vG
id/
Y N
F(c'n 1- V"l4 S o of/ S i 0- !er(vr'``i-,d i T
, Job Address: . Contractor Process No.
Top Ply:
(Type and method oj attachment )
Surfacing:
(Type, if applicable )
Flashing Materials:
(Type and method oj attachment )
Built -Up Applications and Modified Bitumen Systems
Page -3
Job Address:
Contractor
T
inches
inches
A
inches
FILL IN APPLICABLE ROOFING COMPONENTS WHICH MAKE
UP ROOF SYSTEM ASSEMBLY AND THICKNESS OF DECK AND
INSULATION LAYER(S). (Where Roofing Component not used in
Roof System Assembly, fill in with "N /A ".)
7777777777777'"'
Surfacing: f vna,t.J 5 :or. SC&
( briefly describe, cam,
! /applicable) $ c. 4 r Gd r
Bonding Material: -
Ply Sheet(s):
Bonding Material:'`��
Fastener: fU 0
(i /base sheet mech. attached)
Bas S eet: A W eu Gr F
Fastener:
( %rap £ t dlayer I 4
mech. attached )
Top Insulation Layer:
(i /applicable )
>•.:::::.;:. ;::::• :............ Bonding Material:
....... I y bonded )
Fastener:
( i/ insulation
mech. attached)
Insulation:
Bonding Material:
(i/insulation bonded)
Vapor Retarder:
(1/applicable )
Primer:
(t%apphcabie)
Bonding Material:
Of base sheer bonded)
DECK:
Type:
Gage or Thickness:
Density, if concrete deck: p) l
Built -Up Applications and Modified Bitumen Systems
Page-4
Process No.
. Job Address: ,
Contractor
PERIMETER DETAII. #1: Parapet Wall Detail
Process No.
Coping Cap
Gage:
Fastener
Spacing: _ o.c.
Clip Type:
Clip Gage:
Sketch Roofing Components which make up Roof
System Assembly at Perimeter Parapet Walls.
Insert leaders indicating Roofing Component names,
dimensions, thicknesses, etc.
Include fastener type and spacing used for wood -
blocking attachment.
"V"
Deck Type:
(
Deck Type:
Sketch Roofing Components which make up Roof
System Assembly at Perimeter Areas to be Flashed.
Insert leaders indicating Rooting Component names,
dimensions, thicknesses, etc.
Include fastener type and spacing used for wood -
blocking attachment.
PERIMETER DETAIL #2: Flashing Detail
Built -Up Applications and Modified Bitumen Systems
Page -5
. Job Address: ,
Contractor
PERIMETER DETAIL #3: Gravel Stop or Drip Edge
PERIMETER DETAIL #4: Gutter Detail
Built -Up Applications and Modified Bitumen Systems
Page -6
Process No.
Sketch Roofing Components which make up Roof
System Assembly at Perimeter Edge with Gravel
Stop or Drip Edge.
Insert leaders indicating Roofing Components names,
dimensions, thicknesses, etc.
Include fastener type and spacing used for wood -
blocking attachment.
Gravel Stop/grip Edge
Gage:
Fastener
Spacing: ' o.c.
Clip Type: ti/ IA
Clip Gage: N/ p}
Deck Type: k &e
Sketch Roofing Components which make up Roof
System Assembly at Perimeter Edge with Gutters.
Insert leaders indicating Roofing Component names,
dimensions, thicknesses, etc.
Include fastener type and spacing used for wood -
blocking attachment.
Gutter Type:
Gutter Gage:
Fastener
Spacing:
1�1
Deck Type:
\ff
, Job Address:
Contractor
PERMMETER DETAIL #5: 'Other' Detail
Process No.
Sketch Roofing Components which make up Roof
System Assembly at any 'other' Perimeter Condition
which may exisit.
Insert leaders indicating Roofing Component names,
dimensions, thickesses, etc.
Include fastener type and spacing used for wood -
blocking attachment.
0(1A
Sketch Roofing Components which make up Roof
System Assembly at any 'other' Perimeter Condition
which may exisit.
Insert leaders indicating Roofing Component names,
dimensions, thickesses, etc.
Include fastener type and spacing used for wood -
blocking attachment.
PERIMETER DETAIL #6: 'Other' Detail
Built -Up Applications and Modified Bitumen Systems
Page -7
, Job Address: Contractor Process No.
Insert Building and Parapet Heights.
(If no Parapet exists, insert N /A ")
Also insert applicable information pertaining
to the building below.
(See ASCE 7 - 88 Fact Sheet Attached)
Exposure Category:
Classification Category:
At Hurricane Oceanline ?: Y
Basic Wind Speed at
Building Location: 110 mph
Building Condition based on n A • ff
% of Openings: 00 C� l
co 0 trV
GROUND LEVEL
1
titik feet
t
g t p u feet
BUILDING INFORMATION m1
Built -Up Applications and Modified Bitumen Systems
Page -8
Job Address:
Contractor
Built -Up Applications and Modified Bitumen Systems
Page -9
Process No.
Sketch Roof Plan indicating all dimensions, any slopes,
roof drains, crickets, or roof top equipment. Also insert
variable labeled "a" which indicatcs perimeter and comer
dimensions per Chapter 23 of the South Florida Building
Code.
( See ASCE 7 -88 Fact Sheet Attached )
BUILDING INFORMATION 112: Roof Plan with Perimeter and Corner Dimensions
Job Address: Contractor Process No.
-- FOR PLAN EXAMINER USE ONLY --
Roof System Assembly Product Control Approved: Y N
If NO, note any deficiencies:
Desien Pressure Requirements:
Field: psf
Perimeter Areas: psf
Corner Areas: psf
Note any limitations:
Reviewed Details ?:
Notes:
Built -Up Applications and Modified Bitumen Systems
Page -10
Y N
Job Address: Contractor Process No.
Reviewed Field Test Data ?: Y N
Notes:
Additional Notes:
Built -Up Applications and Modified Bitumen Systems
Page -11
Plan Examiner
METRO•DADE
GS Roofing Products Company, Inc.
5525 MacArthur Blvd.
Suite 900
Irving, TX 75038
BUILDING CODE COMPLIANCE DEPARTMENT
SUITE 1603
METRO-DADE FLAGLER BUILDING
140 WEST FLAGLER STREET
MIAMI. FLORIDA 33130.1563
(305) 375.2901
PRODUCT CONTROL NOTICE OF ACCEPTANCE
FAX (305) 375.2908
Your application for Product Approval of GS Built -up Roofing Products under Chapter 8 of the Metropolitan Dade
County Code governing the use of Alternate Materials and types of Construction, and completely described in the
plans, specifications and calculations as submitted by Applied Research Laboratories, Factory Mutual Research
Corporation and Underwriters Laboratories, Inc. has been recommended for acceptance by the Building Code
Compliance Department to be used in Dade County, Florida under the specific and standard conditions set forth
herein.
The approval shall be valid for a period of three years. The Building Code Compliance Department reserves the
right to secure a product or material at any time for a jobsite or manufacturer plant for quality control testing. If
product or material fail to perform in the approved manner, the Code Compliance Department may revoke, modify
or suspend the use of such product or material immediately. The Building Code Compliance Department reserves
the right to require testing of this product or material should any amendments to the South Florida Building Code be
enacted affecting this product or material.
The expense of such testing will be incurred by the Manufacturer.
PRODUCT NO. :
ACCEPTANCE NO.: 94- 0323.43
EXPIRES:
JUN 0 6 1997
METROPOLITAN DADE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
Gil Diamond, P.E.
Product Control Division
Supervisor
- PLEASE NOTE -
THIS IS THE COVERSHEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL
CONDITIONS.
BUILDING CODE COMMITTEE
This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code
Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under
the conditions set forth above.
APPROVED: ' JUN Q 6 1994
Charles Danger, P.E., Direct
Building Code Compliance Department
Metropolitan Dade Counry
NOTICE Ol~ ACCEPTANCE: STANDARD CONDITIONS
1. Extensions of Acceptance may be considered after a new application has been filed and the supporting data,
test reports no older than ten (10) years, have been re- evaluated.
All reports of re- testing shall bear the seal, signature and date of an engineer registered in the State of
Florida.
Any revision or change in the materials, use, or manufacture of the product or process shall automatically be
cause for termination, unless prior approval is granted for revisions or change.
3. Any unsatisfactory performance of this product or process or a change in Code provisions shall be grounds
for re- evaluation.
4. This acceptance shall not be used as an endorsement of any product for sales or advertising purposes.
5. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is
displayed, then it shall be done in its entirety.
6. Product approval drawings, where required for permit applications, shall be provided to the applicant by the
manufacturer or his distributors unless otherwise noted in the Notice of Acceptance. The prints need not be
re- sealed by an engineer.
7 Failure to comply with the Standard Conditions shall be cause for termination of the Approval.
1 Diamond, P.E.
roduct Control Division
Supervisor
Applicant:
GS Roofing Products Company, Inc.
5525 MacArthur Blvd.
Suite 900
Irving, TX 75038
Category:
Sub - Category:
Type:
Sub -Type:
Product Control Notice of Acceptance
Roofing System Approval
Membrane Roofing System
Built -Up Roofing
Conventional
Fiberglass /Asphalt
Product Control No.: 94- 0323.43
Approval Date:
Expiration Date:
LJU?? 0 .6 1J44
JOIN 0 6 1997
GS Roofing Products Company, Inc. manufactures and markets nationally a complete line of residential, commercial
BUR and modified bitumen products. GS Roofing Products Company, Inc. markets these products through local
distribution in the South Florida jurisdiction.
GS Roofing Products and systems are the result of years of manufacturing experience and product development and
have been proven by years of experience in the construction field.
GS offers a variety of approved insulated and non - insulated roofing systems. For detailed system constructions, refer
to t he following publications: "Commercial Roof System Specification Manual" and "Flintlastic Roof System
Catalog."
GS products and systems have been tested in compliance with all provisions of the South Florida Building Code as
well as Underwriters Laboratories, Inc., and Factory Mutual Research Corporation for fire and wind uplift resistance.
GS provides technical service and warranty information through regional offices. For the South Florida Metro -Dade
area, call 1 -S00- 777 -2563.
Pat Neuhaus
Commercial District Manager
2900 Bird St.
Charleston Heights SC 29405
803 744 -7451
11 Diamond, P.E.
Trade Names of Products Manufactured by Others
Product
Product Dimensions Test Specifications Description Manufacturer
Pyrox various PA 110 Polyisocyanurate foam Apache Products Co.
insulation.
ACFoam -II various PA 110 Polyisocyanurate foam Atlas Energy Products
insulation.
Hy -Therm AP various PA 110 Polyisocyanurate foam Celotex Corporation
insulation.
Hy -Therm Nail -Line various PA 110 Polyisocyanurate foam Celotex Corporation
insulation with nailing
surface.
Anchorbond Fastener
Deklast Fastener
Ftiv1 30, FM 60, FM 90
Fasteners
Nail -Tite Type A
Fastener
Nail -Tite Type R
Fastener
Gripdek Fastener
He.xtra Fastener
PA 114
PA 114
PA 114
PA 114 Base sheet fastening
assembly for reroofing.
PA 114
PA 114
Insulation fastening
assembly with plastic and
steel stress plate.
Insulation fastening
assembly with plastic and
steel stress plate.
Base ply fastening system
(for lightweight insulating
concrete only).
PA 1 14 Insulation fastening
assembly with p
Base sheet fastening ES Products, Inc.
assembly for reroofing.
Insulation fastening
assembly with plastic and
steel stress plate.
Gil Diamond, P
Product Control No.: 94- 0323.43
Construction Fasteners
Construction Fasteners
ES Products, Inc.
ES Products, Inc.
IT\V Buildex
IT\V Buildex
Roofgrip Fastener _ _ PA 114
ESL Fastening, Systems
Insult xx Fastener
Ra‘‘.I Drive /Spike
PA 114
PA 1 14
PA 114
steel stress plate.
Insulation fastening
assembly with plastic and
steel stress plate.
ISO 95+ various PA 110 Polyisocyanurate foam International Permalite
insulation
E'NRGY'2 various PA 110 Polyisocyanurate foam NRG Barriers, Inc.
insulation.
ISORoc various PA 110 Polyisocyanurate foam and NRG Barriers, Inc.
rockwool composite
insulation.
Con -Tire Fastener PA 114 Insulation fastening Olympic Fasteners
assembly with plastic and
steel stress plate.
Olympic Fastener PA 114 Insulation fastening Olympic Fasteners
assembly with plastic and
steel stress plate.
GlasFast Fastener PA 114 Insulation fastening Owens - Corning
assembly with plastic and
steel stress plate.
Paroc various PA 110 Rockwool mat insulation. Partek, Inc.
Multi -Max various PA 110 Polyisocyanurate foam RMAX
insulation.
Insulation fastening
assembly with plastic and
steel stress plate.
Insulation fastening
assembly with plastic and
steel stress plate.
Insulation fastening
assembly with plastic and
steel stress plate.
Gil Diamond, P
Product Control No.: 94- 0323.43
ITW Buildex
SFS /Stadler
SFS /Stadler
The Rawlplug
Company, Inc.
Rawlite Fastener
Rawlplug Fastener
Tru -Fast Fastener
.021" min., 2" x 2"
edge metal
High Density Wood various
Fi' erboard
PA 114
PA 114
PA 114
3" min flange ASTM A 525
PA 110
Modified Cold Process ASTM D 3019 Adhesive
Cement Type 1I1
Insulation fastening
assembly with plastic and
steel stress plate.
Insulation fastening
assembly with plastic and
steel stress plate.
Insulation fastening
assembly with plastic and
steel stress plate.
26 ga. corrosion resistant generic
edge metal for system
termination
Asphalt ASTM D 312 ASTM D 312 Bitumen generic
adhesive.
Asphalt Primer ASTM D 41 Asphalt based roof primer. generic
Chopped fiberglass ASTM D 1227 Roof Coating. generic
emulsion
Fiberglas PA 110 Fiber glass roof insulation generic
Flashing Cement ASTM D 4586 or A trowel- grade, cutback generic
ASTM D 2822 bitumen cement mixture
including inorganic fibers
and mineral stabilizers.
Wood fiberboard
insulation.
Modified Plastic Roof ASTM D 4586 Flashing cement
Cement Type I
Non Fibered ASTM D 2824 Roof Coating.
Aluminum Coating
Pcrlite PA 110 Perlite insulation bo
Gil Diamond, P.
Product Control No.: 94- 0323.43
The Rawlplug
Company, Inc.
The Rawlplug
Company, Inc.
Tru -Fast
generic
generic
generic
generic
eneric
Product
Trade Names of Products Manufactured or
- Labeled by Applicant
All Weather/Empire Base 36" x 72'; Roll
Sheet weight: 86 lbs.
Black Diamond Base
Sheet
FlintGlas® Mineral
Surfaced Cap Sheet
Dimensions
36" x 75'; Roll
weight: 75 lbs.
36" x 36'; Roll
weight: 78 lbs.
FlintGlas® Premium Ply 36" x 180'; Roll
Sheet Type IV or VI weight: 40/55 lbs.
Flintglas GTS
Flintlastic FR -P
Flintlastic GMS
Flintlastic GTA
Flintlastic STA
GIasBaseT" Base Sheet 36" x 10S'; Roll
weight: 69 Ibs.
39 -3/8" x 24'9 "; Roll
weight: 92 lbs.
39 -3/8" x 34'2 "; Roll
weight: 105 lbs.
39 -3/8" x 34' 2 ";
Roll weight: 100
lbs.
39 -3/8" x 33' 3 ":
Roll weight: 105
Ibs.
39 -3/8" x 33'; Roll
weight: 90 Ibs.
No. 15 Perforated Felt 36" x 144'; Roll
Test Specifications
ASTM D 1970
ASTM D 3909
ASTM D 2178
Type IV or VI
ASTM D 5147
ASTM D 5147
ASTM D 5147
ASTM D 5147
ASTM D 5147
ASTM D 4601
Gil Diamond, P.E.
Product Control No.: 94- 0323.43
Product Description
ASTM D 2626 Organic asphalt coated felt.
Inorganic glass fiber SBS asphalt
impregnated and coated with fine black
mineral particle surface.
Asphalt impregnated and coated inorganic
glass fiber surfaced with mineral granules
used as the top ply in conventional
built -up roof membranes.
Inorganic glass fiber asphalt impregnated
ply sheet.
Torch applied, granule surface SBS
modified polyester membrane for BUR
flashing.
Asphalt adhered, granule surfaced SBS FR
modified polyester membrane for BUR
flashing.
Asphalt adhered, granule surfaced SBS
modified polyester membrane for BUR
flashing.
Torch applied, granule surfaced APP
modified polyester membrane for BUR
flashing.
Torch applied smooth surface APP
modified polyester membrane for BUR
flashing.
Type II asphalt impregnated and coated
glass fiber base sheet for use in
conventional and modified bitumen
built -up roofing.
ASTM D 226 Organic malt saturated felt.
Roofing Nails min..134" x 11/4" PA 114
Static Asphalt Fibered
Emulsion
Tin Caps
Valley Metal
min 32 ga. x 1
5/8" - 2.0"
ASTM D 1227
Corrosion resistant generic
deformed roof nails.
Roof Coating. generic
Min. 32 ga. x 1 5/8 " -2"
corrosion resistant circular
discs.
Product Control No.: 94- 0323.43
generic
min. 26 ga. 12" ASTM D 525 galv. metal valley flashings generic
wide galv. metal
valley flashings
Gil Diamond, P.
Premium Flex- I- GIasTM
Base Sheet — —
Ultra Flex- I- G1asT`t
weight: 55 lbs.
36" x 72'; Roll
weight: 90 lbs.
39 -3/8" x 50'; Roll
weight: 90 lbs.
Yosemite Mineral Surface 36" x 36'; Roll
Cap Sheet weight: 69 lbs.
ASTM D 4601 Inorganic glass fiber SBS asphalt
impregnated and coated base sheet.
ASTM D 4601 Inorganic glass fiber SBS asphalt
impregnated and coated base sheet.
ASTM D 249 Organic asphalt coated felt with granule
surface.
Gil Diamond, P.E
Product Control No.: 94- 0323.43
Test Agency Test Identifier
Factory Mutual Research FMRC 1994
Corporation
Underwriters Laboratories R1190
Current Insulation
Fastening R
Test Reports
Gil Diamond, P.
Test Name/Report
Applied Research 28013 Physical Properties 06/02/87
Laboratories
Current Insulation
Fastening Requirements
FMRC Approval Guide
1993
FMRC 1994 / /
Fire Classification
Compliance
Product Control No.: 94- 0323.43
//
Date
01/01/94
07/13/87
Test Agency Test Identifier
Factory Mutual Research FMRC 1994
Corporation
Underwriters Laboratories R1190
Current Insulation
Fastening R
Test Reports
Gil Diamond, P
Test Name/Report
Date
Applied Research 28013 Physical Properties 06/02/87
Laboratories
Current Insulation
Fastening Requirements
FMRC Approval Guide
1993
FMRC 1994 / /
Fire Classification
Compliance
Product Control No.: 94- 0323.43
//
01/01/94
07/13/87
Insulation Types:
Wood fiber
Fibrous glass
Perlite
Polyisocyanurate
Composite Board
Rockwool
Maximum Design Pressure
Material Design Pressure
Wood -60 psf
Steel -55 psf
Concrete -75 psf
Lightweight Concrete -45 psf
Poured Gypsum Concrete -45 psf
Cementitious Wood Fiber -45 psf
Maximum Fire Classification
Material Classification
Wood Class 'A'
Steel Class 'A'
Concrete Class 'A'
Lightweight Concrete Class 'A'
Cementitious Wood Fiber Class 'A'
Poured Gypsum Concrete Class 'A'
Product Control No.: 94 0323.43
Note: Fire classifications and maximum design pressures do not reference all assemblies over
all deck types. Review system listings for design pressures and the Underwriters
Laboratories Roofing Materials Directory for Fire Classifications.
Gil Diamond, P
9
SYSTEMS
Deck Type 11: Wood, Insulated, New Construction -
Deck Description: 19 / 32 " or greater plywood or wood plank
System Type A: Base sheet mechanically fastened; all layers of insulation adhered with approved
asphalt.
All General Limitations shall apply.
Insulation Fastener Fastening Fasteners Fastener
Laver Type Detail No. Per Board Density
One or more layers of any of the following insulations:
Approved Type(s): AC -Foam I, E'NRG'Y 2, E'NRG'Y 2 Plus
Minimum: 1" x 3' x 4' N/A N/A N/A N/A
Approved Type(s): ISORoc
Minimum: 1" x 4' x 4' N/A N/A N/A N/A
Approved Type(s): Multi -Max
Minimum: 1" x 4' x 3' N/A N/A N/A N/A
Approved Type(s): High Density Wood Fiber
Minimum: %2" x 4' x 4' N/A N/A N/A N/A
Approved Type(s): Paroc
Minimum: 'A" x 4' x 4' N/A N/A N/A N/A
Approved Type(s): Perlite
Minimum: 3 /<" x 2' x 4' N/A N/A N/A N/A
Approved Type(s): Fiberglas
Minimum: is / x 4' x 4' N/A
Anchor sheet:
N/A
Note: All insulation shall be adhered to the anchor sheet in full moppings of hot asphalt at an
application rate of 25 lbs. /sq. ± 15 %. Please refer to Dade County Protocol PA 117 for insulation
attachment requirements.
All Weather /Empire, Flex- I -Glas or GlasBase base sheet applied to the deck with
approved annular ring shank nails and tin caps at a fastener spacing of 12" o.c. at
the lap staggered in two rows 12" in the field. e sheet shall serve as anchor
sheet for attachment of insulation.
Gil Diamond, P.E.
10
Product Control No.: 94- 0323.43
N/A N/A
Base Sheet:
Ply Sheet:
Cap Sheet:
Surfacing:
Product Control No.: 94- 0323.43
(Optional) Install one ply of All Weather/Empire, Flex- I -Glas or GlasBase base
— — sheet directly over the top layer of insulation. Adhere with any approved
mopping asphalt at an application rate of 25 lbs. /sq. ± 15 %. If base sheet is
applied directly to polyisocyanurate insulation, only a spot or strip mopped
application as detailed in this approval is approved; see General Limitation 44.
Two, three, four or five plies of FlintGlas or #15 Asphalt Perforated Felt ply
sheet adhered in a full mopping of approved asphalt at an application rate of 25
lbs. /sq. ± 15 %. If ply sheet is applied directly to polyisocyanurate insulation,
only a spot or strip mopped application as detailed in this approval is approved;
see General Limitation #4.
(Optional) One ply of FlintGlas Mineral Surface cap sheet adhered in a full
mopping of approved asphalt at an application rate of 25 lbs. /sq. ± 15 %.
(Required if no cap sheet is used) Install one of the following:
1. A two part coating consisting of a base coat of Static Ashpalt
Fibered Emulsion at rate of 3 gal. /sq. or Monoform compound;
surfaced with 1 gal. /sq. Sta -Kool non - fibered aluminum coating or
fibered APOC No. 212..
Maximum Design
Pressure: -45 psf
Maximum Fire
Classification: 'A'. See General Limitation # 2.
Maximum Slope: 3 ":12 "; See General Limitation # 3.
Specification No.: AA • -_ AAA -4 -3, AAA -8 -3, A- 2 -M -3, A- 4 -M -3, A- 6 -M -3, EMS -2 -1V,
2. Flood coat of approved Type III asphalt with an application rate of 60
lbs. /sq.; plus gravel or slag at an application rate of 400 lbs. /sq. or
300 lbs. /sq. respectivly.
Gil Diamond, P.E.
1 1
SPEC..NO. EMS -4 -W
For use over nailable decks
Membrane:
One ply of GLASBASE base sheet and two
plies of FLINTGLAS PLY SHEET, emulsion
surfacing and reflective coating..
Summary of Materials;
Per 100 Square Feet
GLASBASE Base Sheet (1 ply).. 23 lbs.
FLINTGLAS Ply Sheet (2 plies) ... 16 lbs.
Type III Asphalt Moppings [2 @ 25
lbs ea.] 50 lbs.
Emulsion Surfacing STATIC
FIBRATED [6 gals. Dry] 27 lbs.
REXKOTE - SPECTRA® Reflective
Coating [1 gal. Dry] 9 lbs.
Approximate Total Finished Weight 125 lbs.
11
BUILDING
ELECTRICAL
PLUMBING
ROOFING
Owner of
Building
Architect
Contractor
or Builder
Legal
Description
Lot
MIAMI SHORES VILLAGE, FLORIDA
❑ PERMIT N? 3752
❑ Work to be performed under this Permi
Bl
DATE. 19
Contractor's
Licence No.
Subdi-
vision
Address of Value of 11 Amount of
Building Project $ 11 Permit $
This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the applica-
tion herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any
plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked
at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this
permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and
regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes respon-
sibility for work done by his agents, servants or employees.
Signed. INSPECTOR
In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In ac•
cepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee.
CONTRACTOR OR BUILDER
BY AUTHORITY
ABBOT PRINT
■
4
BUILDING
ELECTRICAL
PLUMBING
ROOFING
Owner of
Building t
Architect
Contractor
or Builder
Legal
Description
Lot
o PERMIT x° 3892
❑ Work to be performed under this Permit
a
CONTRACTOR OR BUILDER
MIAMI SHORES VILLAGE, FLORIDA
B1
Signed.
DATE " 19
Contractors
License No.
Subdi-
vision
Address of Value of II Amount of
Building Project $ II Permit $
This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the applica-
tion herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any
plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked
at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this
permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and
regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes respon-
sibility for work done by his agents, servants or employees. r `
In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In ac•
cepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee.
BY AUTHORITY
INSPECTOR
s
ABBOT PRINT