Loading...
271 NE 95 St (4)• Date 2- 23- 01. Job Address Z'71 jV c15.- Legal Description Yid ' P bp 15- Qnu UE 45 s`t; �pa IB ,U.JJGQ4 v- 1 1 1. 1 P/ J - (JCG[ SS# a).5) � a Signa re o� ctor or Zuilder Dat =. Notary as to My Comniss3on * RADON C.C.F. - NOTARY Master Permit # (A6 Phone Lp5-903 - 3023 ROOPING PAVING FENCE SIGN * o VIV INIV UA UP. r A c nm g ro4' uil< • No. CC 919390 11 Personally Known 11 Other I.D. • er * * ** TOTAL DUE Fire Other Zoning Building Electrical ?6 ,,7' l>.15.0 ()Plumbing_ Engineering Sec. 54.1. Air conditioning regulations. (a) All individual air conditioning units installed in walls or windows shall be securely anchored to the walls by approved methods. Units installed over public property, paths of egress or more than ten (10) feet above grade shall be secured to the struc- ture by bolts or screws to resist horizontal wind loads. Such units cantilevering more than eight (8) inches on the exterior of a building shall be supported by steel angle brackets secured by bolting. Bolts to masonry shall be set in lead shields or similarly rot- resistant fastenings. (b) The following special requirements shall apply to the con- trol and regulation of noise nuisance from air conditioning machinery: (1) All equipment, existing or hereafter installed, regardless of location, shall be maintained in good working order. Equipment so located that normal operating noises create a nuisance to adjacent owners or occupants shall be pro- vided with soundproofing, or sound - absorbing baffels, or enclosures, as approved to insure maintenance of a rea- sonable noise level. (2) All equipment on outer walls, on roofs, or in other exposed locations, which are unduly noisy, and which causes valid complaints from adjoining property owners or occupants, may be required to be relocated, redesigned and/or en- closed in noise - retarding materials when, in the opinion of the building official, such enclosure is necessary or would be effective. 43) Special consideration shall be given to the pin'ining of all future installations to minimize the noise nuisance to ad- joining property owners or occupants, and the building official shall have authority to reject or require the rede- sign of any system which, in his opinion, would cause such a,noise nuisance. (c) Violation of this section shall be punished as is now or may hereafter be provided by law. (Ord. No. 299, $ $ 1-3, 2- 21-61) 9 imi Jliores9illage OR 10 A Cgr( ractor Si ature • NOTICE OF COMMENCEMENT A RECORDED COIDY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. 11 3 Wb-. 0/3-3 956 STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: 02 7/ A e. q 5 ST 2. Description of improvement: ib& 4/C Seiarn Name and address of fee simple titleholder: • 5 5. Surety:(Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ Name and address: /i/! A SignQture •f rrn Print Owner's Name Sworn to and subscribed before Notary Public 4 Print Notary's Nam My Commission pires vbw4s this 2 - 3 day of /`j C? i 'F • 33/3 3. Owner(s) name and address: vU -1S 0.2 7/ A)g 9,5 ST. J� /Qir�i F/ • <33438 . Interest in property:� /.!.[.t.A-t f • 4. Contractor's name and address: 5c ca e s 6. Lender's name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, 8. In addition to-himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 42// 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date s TATS: CF FLORIDA, COUNTY OF DADE.. I HERESY CERTIFY that this is a true co of the ungln& Bled h office 7 day of , AD20_A� WITNESS hand and Official Seal." OfARVEY RUVIN, CLERK.. a d Coutity Courts D.C. ,20 6 / 0 1R 1 239 1 1 2001 LIAR 15 13:47 Received; 02.Mar.01 04:26 PM From: 3055670824 To: 9542120988 • Mar 02 01 05:32p Mike Gerrard This Document Prepared By and Return to: CARL M. SUGARMAN, ESQ. 9700 S. DIXIE HIGHWAY SUITE 550 MIAMI, FL 33156 Parcel iDNumber: 11- 32 -06- 013 -3950 Warranty Deed This Indenture, Made this let day of March , 2001 A.D. , Between Joseph Albondonte, a single man of the County of Miami -Dade , state of Florida , grantor, and Sandra Roberts, a single woman who uddr 5s is: Z NE 95th Street, Miami Shores, FL 33138 01 -5972 of the County of Miami -Dade Witnesseth that the GRANTOR. for and in consideration of the sum of TEN DOLLARS ($10) DOLLARS, and other good and valuable consideration to GRANTOR in hand paid by GRANTEE, the receipt whereof is hereby acknowledged, has granted, bargained and sold to the said GRANTEE and GRANTEE'S heirs, successors and assigns forever, the following described land, situate, lying and being in the County of Miami -Dade State of Florida to wit: Lot 20, and the West 1/2 of Lot 21, in Block 29 of the amended plat of MIAMI SHORES, SECTION NO. 1, according to the Plat thereof, as recorded in Plat Book 10, at Page 70 of the Public Records of MIAMI -DADE County, Florida. Subject to restrictions, reservations and easements of record, if any, and taxes subsequent to 2000. and the grantor does hereby fully warrant the title to said land, and will defend the same against lawful claims of all persons whomsoever. In Witness Whereof, the grantor has hereunto set his hand and seal the day and year first above writtcn. SI _+ ed, scaled and delivered In our presence: Witness Witness • a PI f C ' tc STATE OF Florida COUNTY OF Miami - Dade The foregoing instrument was acknowledged before me this Joseph Albondonte, a single man Powered byFax.com 305 567 -0824 State of Florida dress: 270 Grnnd Concores, Miami Shores, FL 33138 day of Ion Al once March he is personally known to me or he has produced his Florida driver's license as ation. fi "�'\ Elizabet Ber Ir cVbyt1oa "ti•ror &noes duns 21, 2003 Pr '• - • Name: Notary Public Laser Lauer Gemmat by 01)',pt y Syrian, In 2000 (663)763 Fonn FLWD•I , grantee. ,2D41 by My Commi991on expires: Page: 2 of 2 p. 2 (Seal) N M MANUAL J: 7th Name of room Length of exposed Room dimensions Ceilngs Ed. wall Condit Option BR 1 8.0 ft 27.0 ft heat/cool BR 2 8.0 ft 24.0 w heat/cool FAMILY 8.0 ft ROOM 34.0 ft . 11.0 ft heat/cool TYPE OF h) h) Area Load (Btuh) Area SURE Clg (tl Clg (f Htg Clg itg Clg 5 ...: 272 .00. 0.00 .... Exposed 3.00% 0.0 D O O D O O 00C 1 00.0. D001 0 111 .... .... 0.0 fine. 0 fr.. ...* .... 6 Windows aa lass eating UU to .0 U'O Nw 23.1 i L i f E f 00000 0 ca N00000 11111I 000000 1039 0 11111€ 0) 0 242 Mill 7 Windows and 27.0 661 437 76 2057 ass doors 0.0 0 0 0 0 Cooling 85.0 979 N 2448 29 2448 0 0 0 0 _._ o 0 0 0 0.0 0 0 0 0 8 Other c 8.6 a 0.0 O O O O O O O 0 0.0 9 Net 14A 10.2 1037 149 170 dosed 0.0 0 walls and U 0.0 0 0 0 0 0 0 0 0 0 partitions 0.0 0 0 0 10 Ceilings 168 432 625 500 __ 607 878 17A 0 0 0 0 0 U 0 0 0 0 O 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 Floors 22A 16.2 437 389 (Note: room 0.0 0 0 perimeter U 0.0 O O O 0 O O 0 O O V 0 is displ. 0.0 0 0 for slab 0.0 0 0 floors) 0.0 0 0 12 Infiltration A 14.5 5.4 36 521 195 45 652 244 105 1520 13 Subtotal losses +8. ±11 +12 4058 0,000 3925 .... .... 6807 Less external heating 0 f 0 .... fO 0 Less transfer 0 ff00 0 .... .... 0 14 Duct loss 406 10% 392 t*** 10% 681 15 Total loss = 13 +14 4464 0104 4317 .... A*** 7488 16 Int. gains: People Q 300 2 ff** 600 2 600 0 .... 0 Appl. @ 1200 0 1000 0 0 0 0 '"' 0 17 Subtot RSH gain= 7 +8.. +12 +16 .... .... 4098 .... 5077 ---- .... 6916 -- Less external cooling .000 "°# 0 000,1 0 .... 0 *" Less transfer 0400 00.0,0 0 * 0 .00 yf 0 * 18 Duct gain 10% 040 410 10% 508 10 '* 692 19 Total RSH gain= (17 +18)*PLF 1.00 * 4508 1.00 5585 1.00 7608 20 Air required (cfm) 0000 236 219 0,001 271 **** 395 369 0 *** • 0. RIGHT -J WORKSHEET Entire House SEARS ROEBUCK & CO. 8000 BROWARD BLVD., Phone: 80. Printout certified by ACCA to meet all requirements of Manual J 7th Ed. 'rr^1jt it50'Ft Right -Suite ResidentiaP 5.0.20 RSR26561 2001- Mar -07 08:24:07 11- ( r) MANUAL J: Name of roorr Length of exposed Roorn dimensions Ceilngs wall Condit Option Entire 8.0 ft House h d LMNG 15.0 8.0 ft 15.0 x h DINNING BATH 8.0 8.0 ft 8.0 ft x 8.0 ft heat/cool TYPE OF CST HTM Area h) Area Area Load (Btuh) EXPOSURE NO. Htg Clg (ft Htg Clg (ft=) Y) Htg Clg 5 Gross 10.2 °... .... Exposed 0.0 °°° .... ...11 walls and 0.0 "'° °°°° 1111 partitions 0.0 O 0 ""' O O .... O «.. 0.0 "~ .... 1011 0.0 .... .... .... 6 Windows and "' 258 5960 .... °°f° glass doors .... Heating U1 8 = 0 0 C 0 C 0 0 11111° 1111 7 Windows and North 27.0 - f°° glass doors 0.0 .... Cooling ENV 85.0 .... 0.0 O O O I O O «.. 0 South 0.0 .... irz 0.0 °°°° 8 Other doors a 10D 9.2 8.6 0.0 0.0 O O O O O O O O O O O O 0.0 0.0 9 Net 10 592 exposed 0.0 0 0 walls and U 0.0 O O O 0 O O O O O O O O 0 0 partitions 0.0 0 0 0 0 10 __.....gs _ 16B 1271 3050 1116 1614 _._ b 17A 0 0 0 0 0 c O O O 0 0 O O 0 0 O O 0 O O O d 0 0 0 0 0 e 0 0 0 0 0 f 0 0 0 0 0 11 Floors 16.2 243 (Note: room 0.0 0 perimeter U 0.0 O O O O O O 0 O O O O O O 0 is displ. 0.0 0 for slab 0.0 0 floors) 0.0 0 12 Infiltration A 14.5 5.4 258 3736 1401 66 956 358 0 0 0 6 87 33 13 Subtotal loss =6 +8. ±11 +12 .... 20677 °... 4390 1111 .... 1100 ..« Less external heating °°°' 0 .... 0 °°°° .... 0 .... Less transfer 11■1 0 i °°°° 0 .... O I .... 0 °111111 14 Duct loss 10% 2068 1091 439 10% 10°4 110 .... 15 Total loss =13 +14 °°°° 22744 "" 4829 1210 .... 18 Int gains: People ® 300 4 .... 1200 0 .... 0 0 0 0 t0 1111111 0 Appi. ® 1200 0 .... 0 0 .... 0 0 0 0 0 17 Subtot RSH gain= 7 +8.. +12 +16 .... °°'° 22483 tell' °"°° 5068 .... 573 °°°° 751 Less external cooling ffe° °°°° 0 .... .... 0 .... 0 .... 0 Less transfer °fee °°°° 0 .... °°°° 0 °°°° I 0 .... 0 18 Duct gain 10% °"° 2248 1094 `°°° 507 10% 57 1094 75 19 Total RSH gain= (17 +18) °PLF 1.00 .... 24732 1.00 °feO 5575 1.00 830 1.00 826 20 Air required (cfm) Ofef 1200 1200 .... 255 271 °°°° 31 .... 40 RIGHT -J WORKSHEET Entire House SEARS ROEBUCK & CO. 8000 BROWARD BLS t Phone: 800-659-1179 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wragl atsofit Right -Suite ResidentialTM 5.0.20 RSR26561 2001- Mar -07 08:24:07 RIGHT -J WINDOW DATA SEARS ROEBUCK & CO. 8000 BROWARD BLVD.. PLANTATION, FL 33388 Phone: 800.659-1179 W S D W G L S S O N A S 0 0 W C W S N K I AL O T H V G N H V V H H N H D Y R L A W R A H L GC R R G T A A W L Z E M D G Z L 0 X Y T M R R LIVING a n s a c n 0 n 1 1 90 1.0 2.0 1.5 4.0 44.0 48.0 48.0 a n ea c n 0 n 1 1 90 1.0 2.0 1.5 4.0 85.0 18.0 0.7 DINNING BATH a n s a c n 0 n 1 1 90 1.0 2.0 1.5 4.0 44.0 6.0 6.0 BR 1 a n s a c n 0 n 1 1 90 1.0 2.0 1.5 4.0 44.0 24.0 24.0 a n ea c n 0 n 1 1 90 1.0 2.0 1.5 4.0 85.0 12.0 0.5 BR 2 a n e a c n 0 n 1 1 90 1.0 2.0 1.5 4.0 85.0 30.0 1.2 a n n a c n 0 n 1 1 90 1.0 2.0 1.5 4.0 27.0 15.0 0.0 FAMILY ROOM a n e a c n 0 n 1 1 90 1.0 2.0 1.5 4.0 85.0 30.0 1.2 a nn a c n 0 n 1 1 90 1.0 2.0 1.5 4.0 27.0 75.0 0.0 wnghtsoft Right-Suite Residential 5.0.20 RSR26561 2001- Mar-07 08:24:07 Ata C:UNy Docunerds1Wrightsoft HVACISANDY ROBERTS.rsr Page 1 8000 BROWARD BLVD., PLANTATION, FL 33388 Phone: 800-659-1179 RIGHT - CALCULATION PROCEDURES A, B, C, D Entire House SEARS ROEBUCK & CO. Procedure A - Winter Infiltration HTM Calculation* 1. Winter infiltration AVF 1.0 ach x 10168 ft x 0.0167 170 cfm 2. Winter infiltration load 1.1 x 170 cfm x 20 °F Winter TD = 3736 Btuh 3. Winter infiltration HTM 3736 Btuh / 258 ft Total window = 14.5 Btuh/ft and door area Procedure B - Summer Infiltration HTM Calculation 1. Summer infiltration AVF 0.5 ach x 10168 ft x 0.0167 85 cfm 2. Summer infiltration load 1.1 x85 cfm x 15 °F Summer TD = 1401 Btuh 3. Summer infiltration HTM 1401 Btuh / 258 ft Total window = 5.4 Btuh/ft and door area Procedure C - Latent Infiltration Gain 0.68 x 55 grub moist.diff. x 85 cfm = 3166 Btuh Procedure D - Equipment Sizing Loads 1. Sensible sizing load Sensible ventilation load 1.1 x 0 cfm vent x 15 °F Summer TD = 0 Btuh Sensible load for structure (Line 19) + 24732 Btuh Sum of ventilation and structure loads = 24732 Btuh Rating and temperature swing multiplier x 0.95 Equipment sizing load - sensible = 23495 Btuh 2. Latent sizing load Latent ventilation load 0.68 x 0 cfm vent x 55 grub moist.diff. = 0 Btuh Internal loads = 230 Btuh x 4 people + 920 Btuh Infiltration load from Procedure C + 3166 Btuh Equipment sizing load - latent = 4086 Btuh *Construction Quality is: A No. of Fireplaces is: 0 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wr.ghtsoft Right -Suite Residential"' 5.0.20 RSR26561 2001 -Mar-07 08:24:07 8000 BROWARD BLVD., PLANTATION, FL 33388 Phone: 800659 -1179 Pro Information Desi • n Information Outside db Inside db Design TD For. Winter Design Conditions Building heat loss Ventilation air Ventilation air loss Design heat load Notes: Method Construction quality Fireplaces Area (ft Volume (ft') Air changes/hour Equiv. AVF (cfm) Space thermostat RIGHT -J LOAD AND EQUIPMENT SUMMARY Entire House SEARS ROEBUCK & CO. Heating Summary Infiltration SANDY ROBERTS 271 NE 95 STREET, MIAMI, FL 33138 Phone: 305 - 903 -3023 Simplified Average 0 Heating 1271 10168 1.0 170 Heating Equipment Summary Make n/a Trade n/a Weather. Miami, Intl Airport, FL, US 50 °F 70 °F 20 °F 22744 Btuh 0 cfm 0 Btuh 22744 Btuh Cooling 1271 10168 0.5 85 Efficiency 100.0 EFF Heating input 0 Btuh Heating output 0 Btuh Heating temp rise 0 °F Actual heating fan 1200 cfm Heating air flow factor 0.053 cfm /Btuh wnghtsoft Right-Suite Residential"' 5.0.20 RSR26561 Summer Design Conditions Outside db Inside db Design TD Daily range Relative humidity Moisture difference 90 °F 75 °F 15 °F M 50 % 55 gr/Ib Sensible Cooling Equipment Load Sizing Structure Ventilation Design temperature swing Use mfg. data Rate/swing multiplier Total sens. equip. load Latent Cooling Equipment Load Sizing Internal gains Ventilation Infiltration Total latent equip. load Total equipment load Cooling Equipment Summary Make KENMORE Trade Kenmore 9600 AC Series TTP036D** *A TW E037E 13 ** Efficiency 13.1 SEER Sensible cooling 25200 Btuh Latent cooling 10800 Btuh Total cooling 36000 Btuh Actual cooling fan 1200 cfm Cooling air flow factor 0.049 cfm /Btuh Load sensible heat ratio 86 % BoJdilmllc values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 7th Ed. 24732 Btuh 0 Btuh 3.0 °F n 0.95 23495 Btuh , 920 Btuh 0 Btuh 3166 Btuh 4086 Btuh 27581 Btuh 2001- Mar-07 08:24:07 FOR: SANDY ROBERTS 271 NE 95 ST MIAMI SHORES, FL. 33138 305 - 903 -3023 FOLIO # 11 -3206- 013 -3950 EQUIPMENT SCHEDULE EQUIPMENT: KENMORE TTP036D***A TWE037E13** SEER: 13.1 SC: 25200 LC: 10800 TC: 36000 CFM: 1200 KW: 10 REF LINES: 3 /4 "SUC; 3 /8LIQ. 1/2' ARMAFLEX INSL. DRAIN LINES: 3/4" PVC. DUCT WORK : R -6 FLEX UNDER CEILING. AH /U ON EXISTING SUPPORT OR SUPPORT STAND. LINES THROUGH ATTIC AS SHOWN OR THROUGH CRAWL SPACE IF NOTED. C/U SECURED TO CONCRETE SLAB USING ANGLE BRACKETS OR 1" #8 NAILS SHOT DOWN THRU BASE I I I g BY: SEARS, ROEBUCK, & CO. 8000 BROWARD BLVD. PLANTATION, FL 33388 CAC 013320 QUALIFIER: DANIEL J. VAYDA 305 -516 -2945 BPR. 9 GARAGE WALL UNIT KITCHEN 20X16 NO A/C LIVING 15X31 15 15 15 15 15 FAMILY ROOM 23X11 271 CFM 10 "X10" 1 DINNING 11X15 BATH 8X8 18 WALL UNIT NC 31 CFM 10'X6" 40 CFM 4 "X6" • �l 15 15 R/A ON LOOVERK DOOR 12 15 BR 2 12X12 (\ 7 CLOSET BR 1 15X12 12 AD 48 MIN 15 15 12 SCALE: 1/4" = 1' SHEET 1 OF 1 Oo6rce (7 ;f e7 /77,Ce(