Loading...
260 NE 95 St (13)BUILDING ELECTRICAL PLUMBING ROOFING Owner of Building Architect Contractor or Builder Legal Lot Description Address of Building MIAMI SHORES VILLAGE. FLORIDA ❑ PERMIT N? 9068 ❑ Work to be performed under this Permit_ CONTRACTOR OR BUILDER Bl. Subdi- vision Sq. Ft Value of Project $ DATE Contractor's License No. Amt. of Permit $ {; This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is he understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes responsibility for work done by his agents, servants or employees. Signed • BY INSPECTOR In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. BY AUTHORITY < 17 BUILDING ELECTRICAL PLUMBING ROOFING Owner of Building MIAMI SHORES VILLAGE, FLORIDA ❑ PERMIT N° 2499 Architect Contractor or Builder Legal Lot Description Address of Building CONTRACTOR OR BUILDER Bl. Work to be performed under this Permit Subdi- vision Value of Project $ DATE 195 Contractor's License No. Amount of Permit $ This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, :statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes responsibility for work done by his agents, servants or employees. Signed. BY INSPECTOR In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village, In ac- cepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. BY AUTHORITY 6 . Estimated Total cost of improvements $ 2 - r MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Date Owner's Name and Address_. �_ . ._,l - . C.L/.q 6' No. ..L -_E C Street.. ( Y _,d7 57 Registered Architect and /or Engineer Name and address of licensed contractor _._ -/ .-' t /l1. M/ i r l 5.57 4/..a ,t7 A- CS Location and legal description of lot to be built on: Lot — C Block Subdivision ._._-- f.?I /}I _Ai 1 _- ___.__5/i 0 fe F.f Street and Number where work is to be done 6 (' /1/ 4"7. c !'7- State work to be done and purpose of building (by floors) f &- - / - 0 ,p $t e F— OA/ ,4 J /'r /o I+/ and for no other purpose. New Building Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Covering (t ' r C' /' Amount of Permit S..- , Zone cubage required plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this pennit, as are licensed by Miami Shores Village. Remarks ( Signed ), f:_.� L_f'�1� _? STATE OF FLORIDA, + COUNTY OF DADE. J ss Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are Permit No 1 v �O Disapproved Notary Public, State of Florida (Signed) Building Inspector O My Commission Expires PL,ANNINC BOARD DATE Chairman Member Member Member Member Member Council Approved Date Disapproved Date ate ? Date — € to me well known, Read, Sworn to and Subscribed before me. NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of 51.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. Application is hereby umdc for the approval of the detailed statement or toe plans and specifications herewith submitted for the build ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whe er herein specified or not. A copy of approved plans and specifications must bc kept at building during progress of the work. Owners Name and Address /' •- 4 Registered Architect and /or Engineer. .......... ry Name and address of licensed Location and legal description of lot to be built on: Lot . Block Subdivisio Street and Number where work is to be done h a Sta work t be done and purpos o b '!ding (by floors ,f,.... - .., d for no other purpose. Ncw Building Remodeling Addition Repairs 1,,/ No. of Stories... To be constructed of Kind of foundat' 4 Estimated Total cost of improvements $ egS..4!. c. l.... Amount of Permit $.. Zone cubage required plan Cubage Distance .to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to.. The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Sup ileiuent, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to bc performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as arc required by the Act. The undersigned agrees to employ only such subcontractors, on work to be perford under this permit, as are licensed by Miami Shores Village. Remarks (Signed)._ STATE OF FLORIDA, COUNTY OF DADE. i SS' Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has careful) read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No.._ »!`' Date....✓,C Z Read, Sworn to and Subscribed before me. Disapproved (Signed) APPLICATION FOR BUILDING PERMIT MIAMI SHORES VILLAGE Building Inspector BUILDING INSPECTION DEPARTMENT Date Date.. 7 _�_ , 19 No..40. l treat._... T Notary Public, State of Florida My Commission Expires _....» Roof Covering to me well known, PLANNING BOARD DATE Chairman Member Mtcrr,ber Member Member .. .. _ ....._......_..._._ ...._....... Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the P1.tnnir,g hoard. A re- inspection fce of $L00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials anti /or workmanship. MIAMI SHORES VILLAGE APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Address Disapproved Date ( Signed) Building llrispector BUILDING INSPECTION DEPARTMENT Registered Architect and /or Engineer Name and address of licensed contractor Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done State work to be done and purpose of building (by floors) Date No Street and for no other purpose. New Building Remodeling a Addition Repairs No. of Stories To be constructed of Kind of Roof Covering Estimated Total cost of improvements $ 7 6-' `` Amount of Permit $ Zone cubage required _Plan Cubage Distance to next nearest building. Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this permit, as are licensed by Miami Shores Village. �J FX rl Remarks (Signed) STATE OF FLORIDA, COUNTY OF DADE. ss Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No 4 _ 2 Date '' �� Read, Sworn to and Subscribed before me. Notary Public, State of Florida My Commission Expires PLANNING BOARD DATE Chairman Member Member Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. 13 74 i 3 / Job Address o d i `7J� � i )�� j ) hSTax Y d �W,, WP$1 1 / . O f M 11 (� "� Hist ricall Designated: Legal Description � �� � � �t �� Y � ated: Yes No Owner/Lessee / Tenant p40 L S TOK(c Owner's Address L I (Mk- M & frA Contractin Co. \cJt✓ &C 4 • (7; Qualifier 0 o S 4 . Se Phone L i 0 7-634 State # C CC 0 57 4 E O 3 Municipal # Competency # Architect/Engineer Address Bonding Company Address Mortgagor f)RI3 & nSU!14K Fl ivniU('e Carpa,7, INC Address 2 S o & Came e. I)ial:iro,4t71R Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL* at i Pear- WOO — L C — PL.A 77r/ ice; WORK DESCRIPTION PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Square Ft. 3 1- T (1 O S F_ WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulatin; co truction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. Signature of owner and/or Condo President P70-Z.1 Notary as to Owner and/or Condo President Date My Commission Expires: FEES: PERMIT ! 0 RADON APPROVED: Zoning Mechanical Plumbing Building Notaryvae4eRtiter tli�'�OdtffYdt~r My Co ssi. EFLWilef46 OYANADEL State of Florida My Comm. Exp:08/05f00( Comm/ CC574608 < C.C.F. v 4462 NOTARY —57, ✓ BOND 3 7 TOTAL DUE 4 /4 re-2 4( 7?g Phone °? S Lid LH. 6 Address /GS' GRfFF +b tai X167 Cc �Cfl Master Permit # Ins. Co. Estimated Cost (value) 1 '73 9‘30 gnature of Contractor or Owner - Builder Electrical OFEV7P PAVING FENCE SIGN 0/ 71..f Ii+iC�iJ U Ott t Date Engineering NOTICE OF COMMENCEMENT PERMIT NO. TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF DADE: 97 R071.621. 1 997 FEB 19 48:32 THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: The U lo 1 l2 t 0 F 1-.0r 9 e lV(/ f /i OF n rS - ' 0 fn B)r,ck 0 of e RrnPnrial Pkrr 0 miArnl OlORPS .Cc.r7Yrril No 2 Q <conli to Plar r Recn .ceD ►r, Plrfir &on ' 10 ) Pt3(je of PuAli. P 2. Description of improvement: R el/\ mVr--- [_Ae r L 6- Rge,ic 26e or 9s stiee<t ll3i 77i 3. Owner(s) name and address: Pcyti I ,S 1614, InRP () C odp,Weie rlal fl A 3 3 '3 � Interest in property: ) 0 p 'J. Qbf) apg Name and address of fee simple titleholder: le 4. Contractor's name and address: 1 5 j Ll - C-Occ / (S— G� /G F� � c)--1 # lK7 Ga co 5. Surety:(Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 6. Lender's name and address: . F6 R.0 0 ( S VON no ON (Q, etilklik u ^ ( Notary Public 0 A f 1 ' Jfi 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be serve° as provided by Section 713.13(1)12)7., Florida Statutes, ') , Name and address: Of ' fki AT ,, koS , Ri (T kiar k I 333 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 10 so. O cei Blvd •40) I t -' o 0 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different 'ate is specified) Signature of Owner Print Owners Name Pi " f U (._ 5 ro N Sworn to and subscribed before me this 1 day of Ft , 19 cr Print Notary's Name 13L4-/c 4'e " t' �►/gk 9dre. u ot .. y� B LANCHte o E 1 O NADEL Y f ,• cralo My Commission Expires: 8 __..s...:. a0pp `u5 MY Comm. Eat): 08105/00 Comm% .�C574808 71■AAAnn.o....w," AA.1 F ROMtOA, COUNTY OF DADE 11 NOM ® Chia Is 0 Oroo co =.• of O o a a4�90 Vann a� ®• d am; d) o t pea' Of o P'a ®biEco or> A B. 10 .45 ,d r Rd OO�fcial Soml. W^ 4Rf�. ,on, A , R rat Ritifil,CLER y 0 r ° ,.., ode Prepared by: Pm//L S Address: 1616 VISA C1leCL6 L v9t/I�Ei22 rtoRipe. 333 ,17 Ft. Ft. Deck type: t.A.Jac Fastener Type: el DETAIL 1 & 2 *Includes Mortar and Adhesive Set Tile Contractor's Name: T f'1e 5 !T (CL t e v v Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. ATTACHMENT SPACING Field: a Perimeter. Corner. Job Address: f7`() Iq E E 1 h �t ROOF CATEGORY • ❑ (Low Slope Application) ❑ (Nail-On Tile) ❑ (Asphalt/Fiberglass Shingles) ❑ ( Metal Roofs \Wood Shingles & Shakes) .(Other) ROOF TYPE ❑ New Roof Wte- roofing ❑ Recovering ❑ Repair ❑ Maintenance Flat Roof Area (ft -3C) 0 Sloped Roof Area (ft 7 Total (fI ' 3 v 5 - 0 - 0 Master Permit No. Exposure category (per ASCE 7 -88): Building Classification category (per ASCE 7-88 table 1): ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed) Page -1 (Mortar -Set Tile) * ROOF PLAN J ttEANHEIGHT Appendix. "E" UNIFORM ROOFING PERMIT APPLICATION • PROCESS No. Deck type 37 jocA Undcrtaymenti "3c (4 1 Insaladonl ROOF SLOPE DETAIL 3. -SLOPED SYSTEMDESCRIPTTON Fastener type &spacing 1-21 06 S 1 01-(LS 11;1;1 Cap Sheet: c/o-4 , 410u_ R.00P - 94 Roof Covering: Page -2 1 Le el'aarr>T SET" Drip edge: ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance-Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals TILE CALCULATIONS (Pmaxl: X A. (Aerodynamic Multiplier): ) - M = lvl PCA: (Pmax2- X A, (Aerodynamic Multiplier): ) - M = Ma: PCA: (Pmax3: x X (Aerodynamic Multiplier): ) - M = M r 3: PCA: METRODADt Litt tilt Corporation 200 Story Road Lake Wales Approved:06 /14/95 I 1 T'1 Cl' CONTROL NOTICE OF ACCEPTANCE FL 338:9 -0632 METROPOLITAN DADE COUNTY, FLORIDA PJIETRO -UADE FLAGLER BUILDING C " BUILDING CODE COMPLIANCE OFFICE SUITE 1503 METRO OADF FLAGIFr1 BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) Z75.2908 Your apC:4: iutl for Pioduct A.pproval of: Nail On .1; urtar or Adhesive Capri Tile tuider Chapter 8 of the Metropol Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Redland T4 • ,ologies, The Ce'riter for Applied Engineering, Inc., and Atlanta. Testing S Engitteeri . has ..e,+ recommended foi acceptance by the Building Code Complie :.' :e office to used in r , C(•o'ay, .lorida under the specific conditions set forth on pages 2 et. sett 111..1 the 5taudar on pag(. This approval :shall not be valid after the expiration date stated below. The Or! - ice of C .'mPhIdnce reserves the right to scc'.ure this product or tnaterial at anytitue from a,iubsite ur mars■:t, : n1!er's tpi.int for quality cosltrol testing. 1f this product or material fails to perform in the approved planner, the Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately.... The applicant shall re- evaluate this product or material should any ammend:nents to the South Florida Building Code be enacted affecting this product or material. The Building, Code Compliance Office reserves the the right to revoke this approial, jilt is detertnined by the Building Code Compliance Office that this product or material, fails to met the requirements of the South Florida Building Code. The expense of such testing will be incurred b . the rnanufaeturet. Acceptance No. :95- 0316.04 _ (Revises Nu.: 94- 0914.23) Expires :06 /14/98 1 I' THIS IS THE COVE 2SHEET, SEE ADDI[TIONA1., PAGES FOR SPECIFIC AND GENERAL , CONDITIONS BUILDING' CODE coMMfrrE:E PRODUCT CONTROL SECTION (305) 375"2902 FAX (305) 372 6339 Product Control Supervisor I This application for Ptodt ct Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Departtlten.t and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. i Director Building Code Compliance Dept. Metropolitan Dade County • Applicant: Lifetile 200 Story Road Lake Wales, FL 33859 Category: SIALCAtegorv: PR0DLJ r C I'IANCt; 1 pF'1Nt � PPR OVAL Prepared Roofing Tile Nail-on/Mortar. Set/Adhesive Set Concrete 'Product Control No.: Approval bate: Expiration pate: 95-0116.0.1 JUN 1 4 1995 JUN 1 4 1998 'vet to Decrr ,tigr� Lifetile is a member of the F3oral Group and is a national producer of extruded concrete tile in California, Texas and Florida. Lifetile manufacturers concrete roof tile for nail -on, mortar set and adhesive set applications. All tile is extruded under high pressure in individual molds with the exposed tile surface finished with a cementitious material colored with synthetic oxide additives. All tile is 'cured' prior to shipping to achieve maximum strength. This Product Control ApproyaLrelateldg Lifetile "Capr-r Ti1t:low4' tile profile. ) JJt f riateiraduct Contra A,pprovvtls for other tile profiles. Lifetile sells tile systems through local, .vltolesale distribution. All profiles have matching, trim pieces used for rake hip, ridge hip, and valley terminations. Tile system accessories such as ventilation systems. flushing systems and birdstc'ps are also available. These accessories are manufactured for all profiles and form a part of this Product Control Approval Lit'etile's "Capri•^' The" roof tile has been tested in compliance with the South Florida Buildin�iz Code requirements for concrete, nail -on, mortar set and adhesive Set tile applications. The minimum roof slope for Lifetile's "CaprirM Tile" nail.on, mortar set or adhesive set tiles shall be 2":12''. See the "Profile Drawing" sectior, in this approval for the "Capri' Tile" profile drawing. The Lifetile " Capr Tile" tile profile has been tested for both wind characteristics and static uplift performance, therefore. any consideration for installation shall he done as a 'Moment Based System' Data for attachment calculations is noted in Tables 1 through 4 of this approval. Contact: Dave Faulkner Technical Services Manager 200 Story Road . P.0, Box 632 Lake Wales, FL. 33859-.632 (813) -9405 2 4 ., ,itaui.RodrIt ue . ; • Produ,St Capri'" Tile • Trim Pieces 4 ' • r varies • '.W °t Vaties varying thickness TRADE N. M s OF'I'RObpTS. MANIJFAC OR h ti4- VoRtiz,b 8Y ,A PPiLiCANT • Product Control No.: _ 95-03I6.O1 Product Dessrlpton , Loi' profile, interlocking, high rehhure e!ctntded concrete roof tile 'egUipped with two nail holes and ' double roller ribs, For direct deck or battehed n3 ;I -on mortar or adhesive set applications,, Accessory trim. concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured nor each tile profile. ' Raul Rodrit;uet • Produtt #30 Felt =43 Cowed Base Sheet Miner'al Surface Cap Sheet Rainproof 11 Ice and Water Shield Mopping Asphalt Flashing Cement WA N/A Lenzingtex -ZB 140 59" x 164' roll Underlayment 22 lbshMl 30" x 75' roll 36" x 75' roll or 60" X 75' roll 36" x 75' roll N/A N/A A1V'011:AC'URgb OpiERS w Prodder / y r r 1 �Clstlptd . i Shttirattd Organic 'rest to be u .ed ns a nailed anchor sheet. AS 11 2626 Saturated and coated • organic base sheet for single or double ply: Underlayment. ASTM D 249 Mineral surfaced usphalt roll roofing for Ue a. a top ply in A double ply underlayment system, PA 104. Single ply. nail -on undcrlayment. PA 104 Single ply, nail -on Underh yment with 2" self - adhering top edge. PA f03 , Selhadhet underlayment for use as a top ply in a two ply Underlayment System with approved 4'30 or 443 as the base Iny't:r. ASTM D 312 type 11I or 1V ASTM 134586 Asphalt for bonding a mineral surface cap to a tnech. attached base sheet in a double ply underlay'ment S) Stem. Cut back, asphalt based, asbestos free, fiber reinforced, trowel grade eetncnt for repair and flashing applications. Monti f *turex generic generic generic Lenzing Performance. Inc. PCA 494- 0527.05 Protect -O -Wrap, inc. PCA 194.07 14.01 W.R. Grace Co PCA 1192-1116.01 generic generic Raul itodrieutt Asphalt Primer ''`) /,°► , s Y ° r1 1J; �''.Ctitback, asphalt : ' generic based corning used to 'ciiitnu bonding of dissimilar materials. Roolin; Nails Tin Caps Wood Battens Tile Nails Tile Screws product Produ . �, r , � : ?-�►1irtrt �,r� nr~st;ri ,tib 1 h �� A1111hafacturer Roof Tile Mortar N/A ( "TileTiter " ") min. 12 ga. with ' / head thin 32 ga. min, 1 o.d. max. 2" o.d. PA 114 Appendix E •meal V.lood Preservers min. I M x 4" institute LP 2 hrZizQLntat min. I" x 4" for use with vertical battens or min, 1" x 2" for use alone min. Sd x3:.:" or min. 10dx3" x 2! 4." long 0.335" head dia. 0.131" shank dia. 0.175" screw thread` $, diameter PA 114 ' Annular ring shank. Appendix E. .. ' hot dipped. electru or mechanically gale. roofing nails for use. in underlaymertt attachment. PA 114 Appendix E PA 114 Appendix E , PA 123 Roof Tile Mortar WA PA 123 Prepared mortar mix Quikrets Constructio ("Quil<rtteg. Roof designed for mortar Products Tile: Monar g1140") set root' tile PCA #94- 0603.01 applications. 3 Corrosion resistant circular disc for use in underlayment attachment Salt pressure treated or decay resistant lumber battens Corrosion resistant, screw or smooth shank nails. Corrosion resistant. coated. square drive. galvanized. coarse thread wood screws Prepared mortar mix designed for mortar set roof rile applications. generic generic generic genetic generic Bermuda Roof Company. Inc. PCA Af94- O6I4.0I Test Product Product bimeri_ ions Salo arllut,,g Description, Manufacturer Roof Mortar N/A PA 123 Prepared mortar mix W.R. Bonsai Co ( "BONSALV Roof designett for mortar PCA #94. 0623.03 Tile Mortar Mix") set roof tile applications. Roof Tile Adhesive ( "Pol> pro® AH 160 ") Hurricane (:lip 3 Fasteners Valle. Flashing Drip Edge S:1t12� PA 114 Corrosion resistant generic min. 1.4" width Appendix E bronze, aluminum, min. 0.060" thick stainless steel, galvanized steel or Clip. L15151RfaS plastic attaehntent ruin. Sd x 11/4" clips for supplemental tile attachment. Clips are installed with corrosion resistant roofing nails compatible with the clip. min 26 go Irvin. 16" ss idth min. 26 ga. min. face flange min. 2" deck flange N/A See PCA Two component Poly foam Products, polyur ethane adhesisa Inc. designed for adhesive PCA 194 - 0401.01 set roof tile applications. ASl N1 A 523 e PA 111 Galvanized steel drip generic . edge Galvanized steel valley flashing Raul Rodriguez. Product Control No.:.95 -Q3 16,114._. menCric T Redland Technologies Redland Techtologies. The Center for Applied Engineering, Inc, The Center for Applied Enigneerittg inc. The Center for Applied. Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied En_gineet ing Inc. The Center for Applied Engineering, Inc. b . The Center for Applied: Engineering, Inc. The Center for .App lied Engineering, Inc. 2:- 7094 -7 25- 709 -1 -.4 25- 7iS3 -1 25- 7183.2 25. 7314 - 2 TitIttilitit4RattoLt 'Dal_ Sta}lc Uplift Testing Dec, 1991 PA101. Static Uplift Testing Dec 1991 PA 10i(A) • p,;vStatiC Uplift testing, PA 101 t; Mortar Set) . Static Uplift Testing PA 101 (Adhesive Set) Static Uplift `testing;, PA 102 (4" Headlap, Nails, Direct :Deck} 5/8" plywood) Static Uplift Testing PA 102 • (4" Headlap. Nails. Battens) St Uplift Testing PA 102 (4" Headlap. Nails. Direct Deck, 15/32" plywood) Static 1:2110 Testing PA 102 (2 Quik -Drive Screws. Direct Deck) Raul Redri2Uez Static Uplift Testint PA 102 (2 Quil; •Drive Screws, Battens) Static Uplift Testing pn 102 (1 Quil; -Drive ;crew. Direct Deck) "Product Control No.: 1 6 NIay 1994 March, 1994 Oct. 1 994 Oct. 1994 Oct. 1994 Feb. 1995 Feb. 1995 ,March. 199$ Test_Ageng_y; The Center for Applied Engineering, Inc. Redland Technologies Redlaud Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Atlanta Testing & Engineering ;r tld+:Miner 2§4`7214 -6 7161 -03 Appendix 11 Letter Dated Aug. 1, 1994 P0631 -01 PO402 Project No 307025 Test t-14DC -7G R I.8�4 R2.894 R3.394 Wind Tunnel Testing PA 108 (Mortar Set) Withdrawal Resistance Testing of smooth vs. screw shank nails Wind Driven Rain PA 100 Physical Properties PA 112 Raul Rodricuez Product Control No.: 95- 0.16.04 Test NAm_eat wad Pate , 5tntia Uplift Testing - March, 1995 : PA 102 (1 Quik - Drive Screw, Battens) . Wind Tunnel Testing PA 108 (Nall -On) Wind Tunnel Testing PA 108 (Nail-On) Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Oct. 1994 Aug. 1994 Deck Type: Wood, on-Jti ted Deck Description: New ConSfruc!ttlbh' ' t 12.''or greater p1ytkiood br``tvood plank. SYSTEM A: • Counter•DattenaApplkkatloh. Slope Range: .2 :LV,lcto / { + 1 ;I2 1 ; , Notu�' : ;C bunter- E9ttetij . nli noted:•LeloW, are regpired for slope range .�'_:2.''.'td ,less f ltran• d! i2tt and arc' optional for slopes of 4":12" to 7 , ']rnrslopesexct;eding 1 " :12 refer to System C. Underlayrnent: ?. install: underlayrnent''system in compliance with Dade County Application Standard PA 118. Vertical Battens: Comments: Install vertical battens in compliance with' Dad • Count} Application Standard PA 118 Horizontal Battens: Install horizontal battens in compliance with Dade County Application Standard PA 118. • Roofing Tile: Install tile in compliance Ivith Dade County Application Standard PA ! 18. (See "Data for Attachment Calculations" in::Iuded in this Approval.) 1. For re- root "; ;2 " p! - wood is an acceptable substrate. Raul Rodrikuet S VS'I'ENIS (CONTINUED) Deck Type: Wood, Non- insulared Deck Description: New construction ' or greater plywood or wood plank. SYSTEM 13: Direct Deck Application Slope Range: 4" :12" to 7":12" Note: System Li is only acceptable in this slope range. For slopes less than 4 ":12 ", ' efer to System A. For slopes in excess of 7 " :12 ", refer to System C. Underlayment: Install undet•laytttent system in compliance 1.'ith Dade County Application Standard PA 118. Roofing Tile: Install tile in compliance with Dade County Application Standard PA 1 1 b (See "Data for Attachment Calculations" included in this Approval.) Comments: 1. For le-root "i plywood is an acceptable substrate. 9' • 10 , • haul Pettirlottel. Product Control No.. _9,5=9_11.12,04_ JUN -30 -95 07.23 FROM.LIFETILE INC SYSTEMS (Cow rlNUEi ) Deck Type: Wood, Non - insulated Deck Description: New construction 19 /,. or greater plywood or Wood plank. SYSTEM C: Horizontal Batten Application Slope Range: 4 ": 12" or greater Note: Horizontal battens, as noted below, are required fur slopes in excess of 7 ":12" and are optional for slopes of 4 " :12" to 7 " :12 ". For slopes less than 4 " :12 ", refer to System A. Install underlayment system in compliance with Dade County Application Standard PA 119. Underl3'•rrtent: Horizontal Battens: Roofing Tile: Comments: Install horizontal battens in compliance with Dade County App, Hon Standard PA 119. Install the in compliance with Dade County Application Standard PA 119. (See "Data for Attachment Calculations" included in this Approval.) 1 . For re -roof applications, " / plywood is an acceptable substrate. •ID.9139791432 Product Control No : 25:11,216-04 PACE 12/19 JUN- 30 - -95 07.23 FROM.LI1'ETILE INC 13 10.613E701432 SYSTEMS (CONTINUED) Deck Type: Wood, Non - insulated Deck Description: New construction "i or greater plywood or N■oo.J plank. Underlayment: Roofing Tile: Comments: Product Control No.: _ j6 94 SYSTEM I): Mortal of Adhesivs: Set AI►pli.:ation Slope Range: 2 ":1 to 7 " :12" Note: System D is only acceptable in this slope range. For slopes in excess of 7 ":12 "; refer to System C. Install underlayment system in compliance with Dade County Application. Standard PA 120. (See System Limitation #5.) Install tilt in compliance with Dade County Application Standard PA 120. (See "Data for Attachment Calculations" included in this Approval.) 1 For re - roof applications, � /," plywood is an acceptable substrate. PACE 13/19 r Tile Profile Capri Tile „.. . , . DATA PUTIATTACIIMCNT ' CALCULATIONi (CON'TINUED) Diter.A Desk • New Construction (min. " 42 " plywood) • Direct DeCk RecoVer/Reroof (min. ' plywood) Tile Tile Profile Application Caprr Tile I Mortar Set _ Adhesive Set Battens 50.90 New Construction Table 4: Attachment Resistance Expressed as a Moment from PA 101 Testing kaulRodrizuez ,••• Product Control No.: 95-0316.04 Table 3-A: Attachment Resistante ExpresSed as a Moment - M, (ft-lbf) froth PA • ,' Tile Two (2) 10d x 3" long nails' Application Tile installation with a 4. headlap using two (2) Approved 10d x 3" long polymel coated, corrosion tesistant ring shank nails installed in Manufactured holes located 2W from the head of the tile. Clips on Pave tile are not required for this attachment configuration unless the Required Moment of Resistance exceeds the values noted atiove. d •••■■••■■■■■■■ 61.50 43.00 (ft-lbf) Attachment Resistance 20.6 86.61 JUN-30-96 07.24 FROM.LIFETILE INC Capri Tile Tile Profile Capri Tile Tile Profile Capri rite Tile Profile 3":12" •■•••••••■••••... Battens Ditect Deck 1 5.92 6.80 DATA Fait ATTACIIMEN7 CALCULATIONS 117.0136781432 Product Control No.: 95-0116.04 Table 1: Aerodynamic Multip(iers ", (al . . from PA 108 Testing 1fe) • X (ft') Batten Application Direct Deck Application 0.27 0 29 Table 2: Restoring Moments due to Gravity - M (ft-lbf) from PA 102 Testing 4":12" 5":12" 6":12" F1atiirf Dire:x Battenr, Direct • Deck Deck 5 82 6.69 5.70 1 6.55 14 Battens Direct Deck 5.56 6.39 5.41 Table 3: Attachment Resistance Expressed as a Moment - M, (ft from PA 102 and PA 102(A) 1 esti ig Tile Approved Approved Approved Application — Nails Screws` Field Clip With: 1 nail 1 2 nail 'I screw 2 ecrews 1 nail 2 nails 1 nail 2 nails Batte4s. 1 4.10 1 7.10 22.90 49. 0 24.20 34.80 22.10 32.20 Direct 1*,k 11.80 J. !!9 .. 25 80 47.10 24.30 35.50 19.00 t L90 Data noted in Table 3 is for installation with a 3" tile headlap. Approved screws are as noted in the 'frade Names of Products Manufactured By Others' and 'Profile Drawings sections of this Approval. Clips on eave tile are not required tor this attachment configuration unless the Required Moment of Resistance ex.ceeds the values noted above. PACE 15/19 7":12" or greater — - Battens Direct L J N/A Approved Eave Clip With: JUN -30 -96 07.24 FROM.LIIFETILE'INC 1: The standard minilnum roof pitch for l..ifetile's "CapriTM Tile ", low profile tile shall comply with Dade Count' Application Standards PA 118, PA 119 or PA 120, depending on the method of installation. SYSTEM LIMITATIONS For nail -on applications, fasteners for mechanical attachment of tiles shall have a head diameter larger than that of the preformed holes in the tile. 3. System installation shall be in compliance with the system specifications outlined in this Product Control Approval. The method of attachment utilized shall provide sufficient attachment resistance expressed as a moment to meet or exceed the requited moment of resistance determined in compliance with Dade County Protocol PA 115 or PA 127. The Lifetile "Capri." Tile" tile profile has been tested for both wind characteristics and static uplift performance, therefore, attachment calculations for installation in compliance with PA 115 or PA 12.7 shall be done as a 'Moment Based System'. 41. For mortar or adhesive set tile applications, a field static uplift test by a Dade County accredited testing agency, in compliance with Dade County Protocol PA 106, shall be performed. s. For mortar set tile applications, 30/90 hot mopp. d underlayment applications may be inst, I perpendicular to the roof pitch unless stated otherwise by the underlayment material manufacturer's published literature. 6 All tiles shall bear the imprint or identifiable marking of the manufacturer's naine or logo for identification in the field. 7. Applications for roofing permits shall include a completed Section 11 of the Uniform Building Permit, a copy of Lifetile's current specifications and details, a copy of this Product Control Approval and a copy of the Product Control Approval of any Roofing Component used in the proposed tile application. Reference shall be made to appropriate data for the required fire rating. 8 The applicant shall ;retail the services of a Dade County certified testing laboratory to maintain quality control in cotnpliauce %vittr the South Florida Building Code and related protocols. Samples taken shall he in compliance with Dade County Protocol PA 112, Appendix 'A'. • 9. Any amendments to these provisions shall he in compliance with Se.tions 203 and 204 of the South Florida Building Code. 'ID.t3139781432 Product Control No.: 90316 04 PAGE 14/19 JUN730-95 07.25 FROM.L1FET1LE , 14C -.- UNIVERSAL TlilM TILE Coulinumnr A, do, Lure PROFILE DRAWINGS 10.0139791432 PAGE 17/19 LIFETILE° Product Control No.: 15:9316:04 JUN-30-96 07.26 FROM L I FET I LE INC ,A,';3 • , r.0.0"."• . . .. . 1 --.. ---- *--------"••••.'\-, • -1 —.0 .' I\ • .1\ Nt -/.... f ‘ A •) 1 P-----".... 7 --3 Li 5' I t \ 3" \ r• • , \ 1 . y ,, , ,. , k • , •, \ „ . ', .‘ ."-.....,.;\,..... I ' , 12, , . , . ‘. '. V . ■ 1 \ .,,,, , • , I , , \\ • % ‘'. \. \ ••' \ ., . `t‘ -.- ...0 I '.1. ___;,..................._____,---.• '.. ' ......... .... •-• .. -...... ',......-4 . -..-. 1 ‘. " 1— - ' • ' , \ c•"" i . 1 ,./.- '•'-- V --- 1/ i . I t ‘.. k.. V ‘. ' %.'-- — —.....oi t . -/ / . / .,......._...„...... r _ u, -, , :.-- I ■ 1 ...._,.._...1_..... ; APPROv ED SCREW FOR SCREW DATA IN TABLE 3 PROFILE DRAWINGS (CONTINUED) 04.'7 10#8136761432 PAGE le/is Product Control No.: 95-0316,(8_.. • • JUN -30 -9S 07.26 FROM, L I Fret• I LE !'11•1C ill .dr197f31432 PAGE 19/19 ME DADL• COUI.ITY, FLORIDA t.1E rrru.DADE FLAGLER 4UILUING 111.twLrnNt3 COW_ COMPLIANCE DCNAH(MEM SUITE 1603 METFRO•DADE FLAt7LER BUILDING 140 WEST FLAMER STREET MIAMI. FLORIDA 33130.1563 UN A; ti ' :.LYJJ.Nltrr_01,11!.11.1oN (305) 375-znol FAX (305) 316 -2900 Es.teus,oms of A; :eptan :- 1.1a; l+e cunsid :red :11 u rte'. .4 appin :anon has been filed and the supporting data, test reports no older than ter, (10) years, I,, ve been re- evaluated. All rep .,.ts of re- testin;; shall beau the >441. slgnawre and date of an engineer rcgrstrred in the State of Florida. Any revision or change in the materials, use, or manufacture of the product or process shall automatically be cause fur In mlil�atiwr unless prior approval is granted for teviswns or change. 3. Any unsatisfarto• performance of this prod;irt en process or a change in Code (envision Shall be grounds for re- evaluation. 4. hi, lcceptance shall not b.- used , ; nn en of an , y product for sates nr , r, Nurp!;es. 5. The Notice of Acceptat.ee manlier prcreJed by the Kurds Dade County, Florida, and followed by the e,cpirat,un d4 ? may tc di :,pfayed i.1 advertising Iiter.rtere•. If any portion of the Notice of Ar.: :.eptance is displayed, thee, it shall be done In its r:: lirety. 6. Pioduo approval draw ing, ., here leguirc'd for permit applic•ation3, shall be: provided to the applicant by the rn: or his rli tiirutprs t ;'i . theraicc noted in the. Notice of Ar :ceptaii . 1111 prints need not be rr•sealed b' are engine°r. Failure to comply' wan Ilre St,ul.1 Ir4� Coalitions sh ;ill be txu.;r fur Ie.mi: :I.)n of the Approval This approval supersedes all in inns approvals. aid Roth I;urz Product Control Sup• :rviso: • METRO-DADE METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING • PRODUCT CONTROL NOTICE OF Quikrcte - Miami 13390 NW 113 Avenue Road Miami, FL 33178 Your application for Product Approval of: Quikrete Roof Tile Mortar FL Tile Adhesive under Chapter 8 of the Metropolitan Dade County Code governing the use o'f Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: The Center for Applied Engineering, Inc., has been recommended for acceptance by the Building Code Compliance Department to be used in Dade County, Florida under the specific conditions set forth on pages 2 through 12 and the standard conditions set forth on page 13. The approval shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at rny time from a jobsite -or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Building Code Compliance Office may revoke, modify or suspend the use of such product or material immediately. The applicant shall re- evaluate this product or material should any amendments to the South Florida Building Codc be enacted affecting this product or material. The Building Code Compliance Office reserves the right to revoke this approval,' if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred -by the man ctur Acceptance No.: 95- 1128.01 Revises No. 94- 0808.01 Approved: March 21. 1996 ACCEPTANCE BUILDING CODE COMPLIANCE OFFICE SUITE 1603 METRO DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI. FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375.2908 INTERNET: mdcc0l ®shadow.net PRODUCT CONTROL SECTION (305) 375 -2902 FAX (305) 372 -6339 / tail Rodriguez Expires: September 12. 1997 Product Control Supervisor THIS IS THE COVERSHEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for `Product Approval has bccn reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Codc Committee to be used in Dade County, Florida under the conditions set forth above. Charles Danger, P.E. Director Building Code Compliance Dept. Metropolitan Dadc County Product Control No.:95- 1128.01 Applicant; Quikrete - Miami 13390 NW 113th Avenue Road Miami, Florida 33178 Category; Roofing Component Sub- Category; Adhesive Type; Roof Tile Mortar FL -15 Sub -Type; Standard Mortar product Control Notice of Acceptance Roofing Component Approval System Description Product Control No.: 95- 1128.01 Approval Date: Expiration Date: Mar. 21. 1996 Sep. 12, 1997 Quikrete - Miami produces a premixed bagged mortar with Masonry Sand for the attachment of clay and concrete roof tile marketed under the trade name Quikrete® Roof Tile Mortar FL -15. Quikretc is specially designed for application of concrete and clay roof tile over a variety of roof deck substrates and underlaymcnt materials. Quikrete® Roof Tile Mortar FL -I5 shall be applied in strict compliance with the tile manufacturers' Product Control Approval, and shall only be used in conjunction with established mortar patty applications as detailed in this Component Approval. Quikrete Roof Tile Mortar is distributed by Tarmac, Fla as Lone Star Roof Tile Mortar. A signed Manufacturer /Distributor agreement is on file at the Office of Building Code Compliance. y r Contact: Tom Shufflcbarger 13390 NW 113 Avenue Road Miami, FL 33178 305- 822 -9255 2 Fr u oaga BRAND NAME: GENERIC PROFILE: PLACEMEN T DETAIL # Atlantis Double Roll A Classic 100 Double Roll A Villa Double Roll A Vanguard Roll Double Roll A Slate ° Large Flat B Shake Large Flat B Flat Vanguard 1 Large Flat B Flat Vanguard II Small Flat B Bermuda Flat Small Flat B Deck Type 1: Wood, non - insulated, new construction Deck Description: Minimum 1 9/ n or greater plywood , or wood plank. Slope Range: 2 ":12" to 7 ":12" 7 ":12" shall be bonded and nailed in compliance with Dade County Protocol PA 120 as detailed in the South Florida Building Code. System A Manufacturer: Monier Roof Tile Corporation Underlayment: Any approved underlayment listed in the 'Products by Other' section of this approval. All underlayments shall be installed in compliance with the South Florida Building Code and as detailed in Application Standard PA 120. Adhesive Placement: Comments: All tile shall be installed in compliance with the Metro Dade County Mortar/Adhesive -set Tile Application Standard PA 120. All 'Component Application And Limitations' noted in the Prepared Roofing Product Control Approval shall apply. Product Control No.:95- 1128.01 Deck Type 1: Wood, non - insulated, new construction Deck Description: Minimum 19 / 32 " or greater plywood , or wood plank. Slope Range: Adhesive Placement: Comments: Product Control No.:95- 1128.01 2 ":12" to 7 ":12" 7 ":12" shall be bonded and nailed in compliance with Dade County Protocol PA 120 as detailed in the South Florida Building Code. System B Manufacturer: Metro & Metro Gem Roof Tile Corporation Underlayment: Any approved underlayment listed in the 'Products by Other' section of this approval. All underlayments shall be installed in compliance with the South Florida Building Code and as detailed in Application Standard PA 120. BRAND NAME: Metro Gem Flat GENERIC PROFILE: Double Roll Small Flat PLACEMEN T DETAIL # A B All tile shall be installed in compliance with the Metro Dade County Mortar /Adhesive -set Tile Application Standard PA 120. All 'Component Application And Limitations' noted in the Prepared Roofing Product Control Approval shall apply. 4 Fran uloaga Deck Type 1: Wood, non - insulated, new construction Deck Description: Minimum "/ or greater plywood , or wood plank. Product Control No.:95- 1128.01 Slope Range: 2 ":12" to 7 ":12" 7":12" shall be bonded and nailed in compliance with Dade County Protocol PA 120 as detailed in the South Florida Building Code. System C Manufacturer: Entegra Roof Tile Corporation Underlayment: Any approved underlayment listed in the 'Products by Other' section of this approval. All underlayments shall be installed in compliance with the South Florida Building Code and as detailed in Application Standard PA 120. Adhesive Placement: Comments: BRAND NAME: Skandia Flat Estate GENERIC PROFILE: Large Flat Double Roll PLACEMEN T DETAIL # A 13 All tile shall be installed in compliance with the Metro Dade County Mortar /Adhesive -set Tile Application Standard PA 120. All 'Component Application And Limitations' noted in the Prepared Roofing Product Control Approval shall apply. Frank Zuloaga • BRAND NAME: GENERIC PROFILE: PLACEMEN T DETAIL # Palema Double Roll A Hacienda Double Roll A Nordic Flat Large Flat B 9" Flat Tile Small Flat B Rustic Shake /Slate ' Large Flat B Natural Slate /Shake Large Flat B Flat Rustic Shake Slate Large Flat B Flat Slate Large Flat B Product Control No.:95- 1128.01 Deck Type 1: Wood, non - insulated, new construction Deck Description: Minimum "4 or greater plywood , or wood plank. Slope Range: Adhesive Placement: Comments: 2 ":12" to 7 ":12" 7 ":12" shall be bonded and nailed in compliance with Dade County Protocol PA 120 as detailed in the South Florida Building Code. System D Manufacturer: Pioneer Concrete Roof Tile. Inc. Underlayment: Any approved underlayment listed in the 'Products by Other' section of this approval. All underlayments shall be installed in compliance with the South Florida Building Code and as detailed in Application Standard PA 120. All tile shall be installed in compliance with the Metro Dade County Mortar/Adhesive -set Tile Application Standard PA 120. All 'Component Application And Limitations' noted in the Prepared Roofing Product Control Approval shall apply. Deck Type 1: Wood, non - insulated, new construction Deck Description: Minimum 19 / 32 " or greater plywood , or wood plank. Slope Range: System E Manufacturer: Lifetile Adhesive Placement: Comments: Product Control No.:95- 1128.01 2 ":12" to 7 ":12" 7 ":12" shall be bonded and nailed in compliance with Dade County Protocol PA 120 as detailed in the South Florida Building Code. Frank Zuloaga Underlayment: Any approved underlayment listed in the 'Products by Other' section of this approval. All underlayments shall be installed in compliance with the South Florida Building Code and as detailed in Application Standard PA 120. BRAND NAME: Capri Shake / Slate GENERIC PROFILE: Double Roll Large Flat PLACEMEN T DETAIL # A B All tile shall be installed in compliance with the Metro Dade County Mortar /Adhesive -set Tile Application Standard PA 120. All 'Component Application And Limitations' noted in the Prepared Roofing Product Control Approval shall apply. Deck Type 1: Slope Range: Adhesive Placement: Comments: Wood, non - insulated, new construction Deck Description: Minimum 19 / or greater plywood , or wood plank. System F Manufacturer: Ludowici- Celadon 2 ":12" to 7 ":12" 7 ":12" shall be bonded and nailed in compliance with Dade County Protocol PA 120 as detailed in the South Florida Building Code. Underlayment: Any approved underlayment listed in the Products by Other' section of this approval. All underlayments shall be installed in compliance with the South Florida Building Code and as detailed in Application Standard PA 120. BRAND NAME: Conosera Classic, French, Ceramic Slate GENERIC PROFILE: Double Roll Small Flat PLACEMEN T DETAIL # A B All tile shall be installed in compliance with the Mctro Dade County Mortar /Adhesive -set Tile Application Standard PA 120. All 'Component Application And Limitations' noted in the Prepared Roofing Product Control Approval . shall apply. 8 Product Control No.:95- 1128.01 • Deck Type 1: Wood, non - insulated, new construction Deck Description: Minimum "/ or greater plywood , or wood plank. Slope Range: 2 ":12" to 7 ":12" 7 ":12" shall be bonded and nailed in compliance with Dade County Protocol PA 120 as detailed in the South Florida Building Code. System G Manufacturer: VandeHey - Raleigh Manufacturing, Inc. Product Control No.:95- 1128.01 Underlayment: Any approved underlayment listed in the 'Products by Other' section of this approval. All underlayments shall be installed in compliance with the South Florida Building Code and as detailed in Application Standard PA 120. Adhesive Placement: Comments: BRAND NAME: Flat Tile Rivera/Shake / Slate GENERIC PROFILE: Large Flat Large Flat PLACEMEN T DETAIL # B B All tile shall be installed in compliance with the Metro Dade County Mortar/Adhesive -set Tile Application Standard PA 120. All 'Component Application And Limitations' noted in the Prepared Roofing Product Control Approval shall apply. Product Control No.:95- 1128.01 93+ mi..CRAL S:.R %ACE ROCr:NG FELT vr'^ : Ate` AT'= •!.- - C ''.t NAIL KR( (HROuGM PLASTIC: Mir cCMEN( (YHEN ADDITIONAL FAILING IS RECUIRED BY CODE) PLACEMENT DETAIL "A" r N. PLACEMENT DETAIL "B" Frank Zuloaga Product Control No.:95 1128.01 WrC <7raO t•Mll NOI *CAC.. 0NtO I.{ KC) Or IRA IN PeCvIWS COWSC ON WO uNxChOC4 Or aor•CCNr IIIC. 90• -:•[OK SWrAC I• C•vC 2O1 •QtC ••C0tn4 CpIKr IS N •CC •l?N 7 IILCt • I +3:1 11::A01 1 r.t *Call V INC I1LC I• tMXhCC< C :CC ► rK ..0C V DC 0r / 1.0 IItCNICNSCr ...IL Kitt 1•40.4. R.SrIC •L.Y CC•Nt trCN •3:ItIO. N•I.I•C IS OCO,IN 3 C0 :C1 •1 - .• -. :.1 .\-ryr. r • I - 1. ri; Component Application and Limitations: Product Control No.:95- 1128.01 1. Quikrete® Roof Tile Mortar F1 -15 shall only be applied over an underlayment installed in compliance with application instructions detailed in its Component Approval. Underlayment shall be any underlayments or underlayment systems listed as approved in Dade County Protocol PA 120. 2. Quikrete® Roof Tile Mortar F1 -15 shall be placed in a 5" x 12" pad at time of application. The mortar pad placement shall be in accordance with the 'Placement Details' provided in this Component Approval. Each generic tile profile requires a specific placement, (see 'Placement Detail listed in this approval'.) 3. Quikrete® Roof Tile Mortar FI -15 shall be applied in accordance with Quikrete Construction Products Specifications. 4. Tile must be applied within 5 minutes of the application of Quikrete® Roof Tile Mortar. FI -15 5. Refer to Dade County Application Standards PA 120, for penetrations and terminations, as well as the 'Placement Details' included with this Component Approval. 6. Refer to Prepared Roofing Assembly Product Control Approvals for system approvals with this Component. 7. Refer to the Prepared Roof System Assembly for fire rating. 8. Field uplift testing shall be performed, in compliance with the test procedure set forth in Dade County Protocol PA 106. Testing shall be performed not prior to 30 days after installation by a Dade County approved laboratory in compliance with the test criteria established in Section 3402.2 of the South Florida Building Code. Quikrete - Miami 1985 Sampson Ave. Corona, CA 91719 ACCEPTANCE NO.: 95 0314.07 APPROVED Mar. 21. 1996 EXPIRES Sep. 12.1997 NOTICE OF ACCEPTANCE STANDARD CONDITIONS 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted , is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product. for sales. advertising or any other purposes. 6. The Notice of Acceptance number preceded by the words Dade County. Florida. and followed by the expiration date may be displayed in advertising literature: If any portion of the Notice of Acceptance is displayed, thertj it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Acceptance contains pages 1 through 13. END OF THIS ACCEPTANCE 13 Fran Zuloaga Product Control No.:95- 1128.01 GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 Mi tnpVOttTAN DADE'COUNTY, F101116.‘ ' ,;. METnO -DARE FLAGLEr1 BUILDING .: UUILDINO;COUE COMPLIANCE DEPAtltMENT•. SUITE 103 ' ::'M 1no- DADE'FLAULESI ; EIJILDINO. • 140 WEST rLAOLEN STREET • MIAMI, FLORIDA Oa130. 5ti3 ' -, '°` '' 1306 '016.2001 .: �. PRODUCT CONTROL NOTICE OF•ACCEPTANCE FAX lava �1e•zoob . Your application for Product Approval of GAF Materials Corporation Mod11141BNumen Roof Systems'under • Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate , l4aterials.pd .types of ' Construction, and completely described in the plans, specifications and calculations as subtiitttdd by Construction' Research Laboratory, Inc., Factory Mutual Research Corporation, South Florida Test Service, Underwritets Laboratories, Inc. and Dynatech Engineering, Inc. has been recommended, for ecc,eptance b the Building Code Compliance Department to be used in Dade County, Florida under the specific and standard conditions set forth herein. The approval shall be valid for a period of three years,: ,The Building Code Compliance Department reserves the , right to secure a product or material at any..tinie fqr a Jobsite or mantifacturer.plant•for quality control testing. If product or material fail to perform In•tht•approved+luanx ri : the.Code'Compliance'Departrnent may revoke, modify or suspend the use of such product.or inhteriat t nmediately:,ftle Building C9de.,COggp1iiince Iepartment reserve's the right to require testing of this product or'material any amefdtnents•to t ie S li"Florida • buildin g Code be enacted affecting this product or material. ;' o '• a p''•' "'• • r•• • The expense of such.,testing Will bkincurredby ti'e NKr PRODUCT NO. s' ACCEPTANCE NO.; - 93-030.06 /. EXPIRES: ' NOV 1 n • ,�.99T •r the conditions set forth above "' APPROVED: MAYA 4 1995 . y :. • r�:. • • uI Rodrig • , ,Product Conte i tMvislon .: Supervisor. • - PLEASE NOTEr..4.. , \ , ;, : ; ''= . •.t • THIS IS THE CO�VERSHEEJ'...SE . Abel,TIONAL V � ES FOR SPECIFIC AND GENERAL CONDITIONS. - 1. , • • BUU.DING.CODE COMMITTEE.: • . This application for Product Approval has been reviewed by the Metropolitan. Dade County Building Code Compliance Department and approtfed,by the' Building Code Committee to be used in Dade Cou n l orida under arles Danger, P.E., Director ' Building Code Compliance Department Metropolitan Dade County • :1; t. SYSTEMS PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING SYSTEM APPROVAL Applicant: GAF Materials Corporation Product Control No.: 95- 0330.06 • 1361 Alps Road Wayne, NJ 07470 Approval Date: MAY 0 4 1995 Expiration Date: NOV 1 0 1997 Category Membrane Roofing System Sub - Category; Built -up Roofing Type, Modified Bitumen Sub -Type: SBS, APP System Description GAF Materials Corporation has been manufacturing commercial roofing products for more than 100 years. GAF produces a wide range of roof products for built -up roofing systems. The modified bitumen products include both APP and SBS products in smooth, granule fire rated versions. In addition, GAF offers two ply modified systems to meet the specification requirements for multilayer SBS modified specifications. GAF products are distributed through a wide network of roofing wholesale distributors throughout the South Florida area. GAF provides warranted systems over various insulated and non - insulated substrates, copies of which can be obtained from GA and can be found in the Ruberoid Modified Bitumen Application and Specification manual published annually. GAF roof system assemblies have been extensively tested at Factory Mutual Research Corporation and Underwriters Laboratories. GAF modified bitumen membranes have been tested in compliance with ASTM D 5147 test requirements. Contact: William J. Woodring Director of Technical Services (201) 628 -3000 2 Product Control No.: 95- 0330.06 Insulation Typea: Fibrous glass Perlite Fiberboard Polyisocyanurate Expanded polystyrene (EPS) Polyisocyanurate Composite Board ,Maximum Design Pressures Material Design Pressure Wood -60 psf Steel -75 psf Concrete -248 psf Lightweight Concrete -45 psf Poured Gypsum -45 psf Maximum Fire Classification Material Classification Wood Class A Steel Class A Concrete Class A Lightweight Concrete Class A Poured Gypsum Class A Note: Fire classifications and maximum design pressures do not reference all assemblies over deck types. Review system listings for design pressures and the Underwriters Laboratories Roofing Materials Directory or other approved testing agency listing directory for Fire Classifications. 3 Product Control No.: 95- 0330.06 Product Ruberoid® Torch Smooth Ruberoid® Torch Plus (Granule) Ruberoid® Torch Granule Ruberoid® Torch FR Ruberoid® Mop Plus (Granule) Ruberoid® Mop Granule Ruberoid® Mop FR Ruberoid® 20 Ruberoid® 30 Ruberoid® 30 FR TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Test Product Dimensions Specification Description 1 sq. roll ASTM D 5147 Heavy duty, polyester reinforced, 87 lbs. asphalt modified bitumen membrane. % sq. roll 93 Ib. roll 1 sq. roll 102 Ib. roll 3/4 sq. roll 90 lbs. 1 sq. roll 102 lbs. 1 sq. roll 103 lbs. 1 sq. roll 105 lbs. r 1.5 sq. roll 1 sq. roll 92 lbs. 1 sq. roll 92 lbs. Ruberoid® Mop 170 FR 1 sq. roll 103 lbs. Product Control No.: 95- 0330.06 ASTM D 5147 Heavy duty, polyester reinforced, asphalt modified bitumen membrane. ASTM D 5147 Asphalt impregnated, coated felt, surfaced with mineral granules. ASTM D 5147 Non -woven polyester mat coated with fire retardant polymer modified asphalt surfaced with mineral granules. ASTM D 5147 Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. ASTM D 5147 Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. ASTM D 5147 Non -woven polyester mat coated with fire - retardant, polymer modified asphalt surfaced with mineral granules. ASTM D 5147 SBS modified asphalt base sheet reinforce with a glass fiber mat. ASTM D 5147 Non woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. ASTM D 5147 Non woven fiberglass mat coated with fire retardant, polymer modified asphalt surfaced and surfaced with mineral granules. ASTM D 5147 Non -woven polyester mat coated with fire retardant polymer modified asphalt surfaced with min • I gr, u 4 Raul Rodriguez Product GAFGLAS® 3' x 36" Stratavent® (Vent Ply) 69 Ib. roll for Nailable Decks. GAFGLAS® 3' x 36" Stratavent® (Vent Ply) 69 Ib. roll Perforated GAFGLAS Ply 6® GAFGLAS Ply 4 GAFGLAS #75® GAFGLAS0 3' x 36' Mineral Surfaced 76 Ib. roll Cap Sheet GAF Materials Corporation Asphalt Concrete Primer GAF Materials Corporation Fibered Aluminum GAF Materials Corporation WeatherCoat® Emulsion GAF Materials Corporation Jetblak All Weather Plastic Cement Dimensions 3' x 180' 45 lb. roll 3' x 180' 40 lb. roll 3'x108' 75 Ib. roll 5, 55 gallons ASTM D 41 4, 5 gallons k 5 gallons 1, 5 gallons Test Specificatioa ASTM D 4897 D 3672 ASTM D 4897 Fiber glass base sheet impregnated and D 3672 coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. ASTM D 2178 ASTM D 2178 ASTM D 4601 5 Product Control No.: 95- 0330.06 Product Description Fiber glass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Type VI asphalt impregnated glass felt with asphalt coating. Type IV asphalt impregnated glass felt with asphalt coating. Asphalt impregnated and coated glass mat base sheet. ASTMD 3909 Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. Asphalt concrete primer used to promote adhesion of asphalt in built -up roofing. ASTM D 2824 Fibered aluminum coating. ASTM 1227 Surface coating for smooth surfaced roofs. ASTM D 3019 Refined asphalt blended with a mineral ASTM D 3409 stabilizer and fibers. Permits adhesion to wet and dry surfaces. Raul Rodriguez / 41-) iirs. Product Dimensions GAF Materials 1, 5, 53 gallons Corporation Jetblak Flashtite® Cement GAF Materials 1, 5, 53 gallons Corporation Plastic Cement GAF Materials Corporation Mineral Shield® Granules GAFTEMP® various Isotherm R GAFTEMP® Composite various GAFTEMP® Permalite various GAFTEMP® Fiberboard various GAFTEMP® High Density Fiberboard GAFTITE® # 12 Standard Roofing Fastener GAFTITE') #14 Heavy Duty Roofing Fastener NTB Fasteners various r. Test Product Specification Description ASTM D 4586 Asphalt flashing cement. ASTM D 4586 Trowel grade, asphalt plastic cement. PA 110 PA 114 GAFTITE® Base Sheet PA 114 Fastener and Plate Galvalume Plates 3" and 3 'h" PA 114 Polypropylene Plates 3" and 3 '/2" PA 114 PA 110 Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insulation. PA 110 Perlite insulation board. PA 110 Fiberboard insulation. PA 110 PA 114 Insulation fastener for steel, wood and concrete decks. PA 114 Fastener for use in gypsum, tectum and lightweight insulating concrete decks. Base sheet fastening assembly. Round galvalume stress plates. Round polypropylene stress plates. 6 Product Control No.: 95- 0330.06 Granules for surfacing of exposed asphalt, cold process or emulsion. Polyisocyanurate foam insulation. High density wood fiberboard insulation. 0 Insulation fastener for steel and plywood decks. Raul Rodriguez Product Hy Therm AP Pyrox White Line ACFoam Composite various ACFoam 1 ACFoam II Hy -Tec Hy -Tec 2 Hy -Therm AP Hy -Therm White Line Hy -Therm Pyrox Energy LOk Thermax TRI -STAR TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS Test Dimensions Specification various various various various various various various various various various various various PA 110 PA 110 PA 110 PA 110 PA 110 PA 110 PA 110 PA 110 PA 110 PA 110 PA 110 PA 110 PA 110 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation 7 Polyisocyanurate foam Atlas Energy insulation Products Polyisocyanurate foam • Atlas Energy insulation Products Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Raul Rodriguez Product Control No.: 95- 0330.06 Manufacturer Apache Products Co. Apache Products Co. Apache Products Co. Atlas Energy Products Celotex Corp. Celotex Corp. Celotex Corp. Celotex Corp. Celotex Corp. Celotex Corp. Celotex Corp. Product Dekfast Fasteners #14 Test Product Dimensions Specification Description PA 114 Dekfast Hex Plate 2 7/8" x PA 114 3 1/4" Dekfast Lock Plate 3" x 3 1/4" PA 114 Dekfast Fasteners #15 Dekfast Fasteners #12 TPR ISO 95+ GW various ISO 95+ GL various ISO 95+ Composite ISO 95+ Asphalt High Density Wood various Fiberboard Perlite Insulation various PA 114 PA 114 PA 114 PA 110 PA 110 PA 110 PA 110 Insulation fastener for steel and concrete decks Galvalume hex stress plate. Polypropylene locking plate. Insulation fasteners for concrete decks Insulation fastener for steel and wood decks. Aluminum fastener for lightweight, gypsum and tectum decks Polyisocyanurate foam insulation 8 Polyisocyanurate foam insulation Polyisocyanurate foam insulation ASTM D 312 Type 1II or IV hot asphalt bitumen adhesive PA 110 PA 110 Wood fiber insulation board Perlite insulation board Product Control No.: 95- 0330.06 Manufacturer Construction Fasteners, Inc. Construction Fasteners, Inc. Construction • Fasteners, Inc. Construction Fasteners, Inc. Construction Fasteners, Inc. Creative Construction Components Firestone Firestone Polyisocyanurate / perlite Firestone ridged insulation Firestone generic generic generic Product Red Rosin various Roofing Nails Tin Caps Type X Gypsum various Sturdi -Top al MB aluminum roof coating Grundy Industrial Emulsion #14 Roofgrip Gripdek Fastener Premium Metal Plate Standard Plastic Plate Karnak No. 169 Karnak 97 Dimensions • Specification Description Minimum # PA 114 12 • Min. 32 ga. x 1 5/ to various PA 110 3" square 3" round Test Product PA 121 Aluminum roof coating Grundy Industries PA 121 PA 114 Insulation fastener steel, ITW Buildex wood or concrete decks PA 114 Insulation fastener PA 114 3" square galvalume AZ55 ITW Buildex stress plate PA 114 r Polyolefin plastic plate ASTM D 2824 Aluminum roof coating PA 121 Barrier Board Plus various PA 110 9 Rosin paper for barrier layer on wood decks Corrosion resistant annular generic ring shank nails Corrosion resistant circular generic discs. Fire resistant rated gypsum generic Wood fiberboard Asphalt emulsion Roof coating Polyisocyanurate foam / wood fiber insulation Raul Rodriguez Product Control No.: 95- 0330.06 Manufacturer generic Georgia - Pacific Grundy Industries ITW Buildex ITW Buildex Karnak Corp. Karnak NRG Barriers, Inc. Product E'NRG'Y PSI -25 various PA 110 E'NRG'Y -1 various PA 110 E'NRG'Y -2 Plus various PA 110 E'NRG'Y- I Plus various PA 110 E'NRG'Y -2 various PA 110 Con -Tite (Fluted Nail) Olympic Polypropylene Olympic Fastener Olympic C -R Base Sheet Fastener and Plate Test Product Dimensions Specification Description PA 114 Olympic Standard 3" round PA 114 Olympic G2 Plate 3.5" round PA 114 3.25" round PA 114 PA 114 PA 114 10 Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Concrete deck insulation fastener 3" round galvalume AZ55 steel plate 3.5" round galvalume AZ55 steel plate. Polypropylene plastic plate Insulation fastener Base sheet fastener and plate. Raul Rodriguez Product Control No.: 95- 0330.06 Manufacturer NRG Barriers, Inc. NRG Barriers, Inc. NRG Barriers, Inc. NRG Barriers, Inc. NRG Barriers, Inc. Olympic Manufacturing Group, Inc. Olympic Manufacturing Group, Inc. Olympic Manufacturing Group, Inc. Olympic Manufacturing Group, Inc. Olympic Manufacturing Group, Inc. Olympic Manufacturing Group, Inc. Fiberglas various PA 110 Fiber glass roof insulation Owens- Corning Fiberglas Corp. Insul -Fixx P Rawl Drive Rawl Fasteners #12 Rawl Fasteners #14 Test Product Dimensions Specification Description Product Foamglas Board various PA 110 Multi -Max various PA 110 Thermaroof various PA 110 Composite Fes -Core various PA 110 Fesco Foam various PA 110 UltraGard Gold various PA 110 HD Insul -Fixx PA 114 Fastener Insul -Fixx Fastener PA 114 Insul -Fixx S 3" square PA 114 3" round PA 114 PA 114 PA 114 Expanded glass insulation board. 11 Polyisocyanurate foam insulation Polyisocyanurate foam / perlite composite insulation Polyisocyanurate foam / fescoboard insulation Polyisocyanurate foam / fescoboard insulation Polyisocyanurate foam insulation Insulation fastener for use in steel and concrete decks Insulation fastener for„jteel and wood decks 3" square galvalume AZ55 stress plate PA 114 -3" round plastic stress plate Insulation fastener And steel and plastic stress plate for concrete deck Insulation fastener for steel and wood decks Insulation fastener for use in steel, wood or concrete Raul Rodriguez Product Control No.: 95- 0330.06 Manufacturer Pittsburgh Corning Rmax, Inc. Rmax, Inc. Schuller International Inc. Schuller International Inc. Schuller International Inc. SFS /Stadler SFS /Stadler SFS /Stadler SFS /Stadler The Rawlplug Company Inc. The Rawlplug Company Inc. The Rawlplug Company Inc. Product Rawl 3" Plate Rawl Spike Rawlite Dimensions 3" round Rawlite 3" Plate 3" round Test Specification PA 114 PA 114 PA 114 PA 114 12 Product Description 3" round galvalume AZ55 steel plate Insulation fastener and steel and plastic stress plate for concrete deck Insulation fastener for cementitious and gypsum decks 3" round galvalume AZ55 steel plate for use with Rawlite fasteners Product Control No.: 95- 0330.06 Manufacturer The Rawlplug Company Inc. The Rawlplug Company Inc. The Rawlplug Company Inc. The Rawlplug Company Inc. Test Agency Construction Research Laboratory, Inc. Factory Mutual Research Corporation South Florida Test Service Underwriters Laboratories, Inc. Dynatech Engineering, Inc. Test Identifier #4818 J.I. OT4A l .AM J.I. 1V7AO.AM J.I. 1V8A4.AM J.I. 1 R 1 A6.AM J.I.0T2Q4.AM J.I. 0Q6A6.AM J.I. 2M0A4.AM J.I. 3X3A2.AM J.I. 0Y9Q5.AM J.I. 3X3A2.AM GAF -53 -X -915 R1306 3600.02.95 Test Reports Test Name/Report Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Physical Properties Fire Classification Wind Uplift, Small Scale 13 Raul Rodriguez Product Control No.: 95- 0330.06 Ott 07/10/87 08/26/92 • 07/16/92 06/28/93 11/15/91 10/17/91 07/16/91 03/21/87 08/02/94 07/29/94 08/02/94 03/08/91 08/01/94 02/02/95 Gener Limitation.: • 1. All asphalt shall comply with ASIR1 I) 312 type 111 or type IV requirements. All proposed asphalt producer must be approved by the applicant. Dire ratings arc determined by a combination of slope, deck type and assembly. Refer to current Undetwritets Laboratories Roofing Matetials [directory or other fit e testing data listed by an approved listing laboratory agency. Fire ratings shall. be in compliance with Sections 3401.5 and 3401.6 of the South Florida F3uildiug Code. a Product t:vnu ut No.: 95- U33t1.O6 3. ;.taximunk slope range shall vary for each system; ccinsutt currenr Undenvritcrs Laboratories Roofing lvluterials Directory and rn;utufacrutet's specifications t„r compliance .. Intl design criteria for each project. An overla\;recovety board insulation panel is required on all application; u%er closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet may be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip or spot mopped 8" ribbons in three rows, one ;it each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the slips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow class ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq.. Note maximum iu . desicn pressure restrict on spot attached systems. 6. All work shall be perforated by a Contractor licensed to do roofing work in Dade County. • Contractor shall be familiar with the details and specifications published by the manufacturer. 8. Any amendments to these provisions shall be in compliance with Sections 203 and 204 of the South Florida Building Code. In re- roofing applications, moisture content in an existing built -up roof must be in compliance with Section 34019(c) of the Soutar Florida Building Code. Prior to application, all existing roof surfaces used as a bonding substrate shall he iested for uplift resistance in compliance with Dade County Protocol PA 12.t to the d,alculated design pressure of the roof deck. 9 . If required, any Factory Mutual Approved vapor barrier in conjunction with proprietary or approved adhesives may be used prior to the application of the insulation layer. 10. Perimeter and corner areas shall have an increase in fastener density for both insulation and base sheet in compliance with Dade County Protocol PA 117 of the South Florida Building Code. 11. All attachment and siting of petinheter nailers and metal profile designs shall confotin with Dade County Protocol PA 111 of the South Florida Builfji)t Cspdc. 168 Raul Rodriguez Product Control No.: 95- 0330.06 12. Flashings shall be installed according to the manufacturers standard details, and may be applied in cold application adhesive, approved asphalt or may be applied in conjunction with an approved torch applied modified bitumen membrane. Specific details, approved by the manufacturer, shall be submitted with the Section II Permit Application. 13. Roll good materials shall be stored in strict compliance with GAF Materials Corporation requirements. 14. Consult current Underwriters Laboratories Directory for the appropriate coating for each roofing assembly to obtain the required fire rating. The assembly shall be installed in strict compliance with Chapter 3401.5 and 3401.6 of the South Florida Building Code for maximum fire classification. 15. Asphalt moppings shall be with applied with asphalt approved by the applicant and shall be approved in compliance with equiviscous temperature (EVT) methods of asphalt application. Asphalt containers or bulk tickets shall indicate an EVT, finished blowing temperature (FBT) and flash point. Asphalt types and temperature ranges shall be in compliance with Subsection 3403.4(a)(3) of the South Florida Building Code. 16. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt at an application rate of 25 lbs /sq. f 15 %, or mechanically attached using the fastening pattern of the top layer. Refer to manufacturer's literature and/or the NRCA Roofing and Waterproofing Manual for correct application procedures of insulation panels in approved asphalt or adhesive. 17. Pre- assembled cap nails may only be used for termination of fully bonded surfaces such as mechanical termination at wood blocking, head and side laps, and base flashing terminations. Cap nails shall not be used for the mechanical attachment of a base sheet. Tin caps are required by the South Florida Building Code. 18. The submission of system specifications and details shall accompany the Section II Building Code Permit. This information is available in the publications listed in the 'System Description' of this Product Control Approval. The submission of these docurrlents, as well as the proper application and installation of all materials shall be the sole responsibility of the contractor. 19. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 20. Fastener spacing for base sheet attachment is based on a minimum withdrawal resistance value of 250 Ibf as tested in compliance with Dade County Protocol PA 105. If the fastener values as tested are below 250 lbf a professional engineer may submit a revised fastener spacing utilizing the withdrawal resistance value taken from Dade County Protocol PA 105. Calculations shall be based on a rupture value (the fastener stress plate pulling over the base ply) of n move t 90 I,bf.. , li / /-1: • �,: ) Raul Rodrigu '4 / . c. 169 21. Fastener spacing for insulation attachment is based on a Minimum Characteristic Foree (F') of 300 Ibf. as tested in compliance with PA 105. If F' as field tested, is below 300 lbf. insulation attachment shall riot be acceptable. 22. GAFdoes.not allow application of roof coatigs, other than a pour coat of asphalt and gravel, over its granule surfaced Ruberoid® products. 23. In addition to the requirements of this Product Control •Apprfival and the South Florida Building Code, applicator shall follow the manufacturer's specifications. Product Control No.: 95- 0330.06 .4 Raul Rodriguez :. e U 170 V 02/84/97 12:40 Nil . 480 Membrane Type: APP Deck Type 1: Deck Description: System Type E: Base Sheet: Fastening: Note: Ply Sheet: Membrane: Surfacing: Maximum Design Pressure: Maximum Fire Classification: Maximum Slope: Specification No.: • Wood, Non - insulated X or greater plywood or wood plank decks Base sheet mechanically fastened. All General and System Limitations apply. One ply of GAFGLASB` Ply 4, GAFGLAS GAFGLASID Stratavent® (Vent Ply) for Nallabl described below: Lap base sheet 4" and attach to the wood deck o.c. at the sidelap and nvo staggered rows 12" o. Ply 4 aud.Ply 6® applications require sheathi application of anchor sheet. (Optional) One, two or three plies of GAFGLA in type III or IV asphalt at an application rate of One ply of Ruberoid® Torch Smooth, Ruber Torch Plus Granule or Ruberoid® Torch manufacturer's application instructions. (Optional) Install one of the following: 1. GAFGLAS® Mineral Surface Cap Sheet application rate of 25 Ibisq. ± 15%. Karnak 97 or GAF Fibered Aluminum at Emulsion at 3 galisq (for Torch Smooth a z -60 psf; see System Limitation 43. 'A'; see General Limitation #2. 3:12; see General Limitation 43. N- 1 -1 -TS, N- 1- 1 - TSC, N- 1 - - 40 Raul Rodriguez uct Control No.: 95- 0330.06 GAFGLAS #75 or s mechanically fastened as roved nails and in caps 9" ed on the sheet. r over wood decks before 4 or GAFGLAS .t15%. ,a Ply 6® orcb Granule, Rubernid U h applied according to III or IV asphalt at an /sq. or GAF WeatherCoat ns only).. bate P g a Job Address 2 ( D iV F 4' 6 j T_ [.. a/a 4 1 5f 5 , Tax Folio ' . J . 26' Legal Deacript iota D / Lo % � - i g , 9 .t i,. / 0 - 5 1t'as er Permit. ev2.7 7 / Leases / Te nantfjCJ tif9E%4/180, MAR- 18 —'91 MON 12:31 ID:CITY Of rrwt :.- wJr�:.:..�e•. ti...L... w i • _.._ _..eday PERilltr APPLICATION Owner's Address ? to ® Al: F 9 5 5 i et /.q►1't 15/tOMS n. Phone lSl CoXA/? fT,t Roai iy 0 L - Addrem api 4suralitier $ E jOH /9, M,ORTI N GR ` / Phone 1 t / 75g Stated RC Of12Obti 5 Comps Architect /Engineer 7:cr Its tgagor grit Type (rip2Ro one): (BIIILDIN+ Si;' attire - o Dotes 44,7 DESCRIPTY, 3, 7 R (2FF - /IL'Rr1 v F 0/ eLatzlI dP agT d o thh v rcd 7,AG-F�.�Sbt�nrG, 6hC �r�v a �9n� ' �'r s a veAk ev,T,ti 5Ao N1,) ce f 8 09 'ill 5b? 4 ,rr N c. ,9d P1^4 Pd 0 R �z,) Svetre Ft. 2_0 N/,; AdltilAAA4! � ! t . er antr Condo PERKT APPROVED: Zoning Mechanical Pk3 is'. /9 q wAIMETG TO OWNER: YOU MUST RECOIL MAY RESULT MN YOUR PAYING TO OBTAIN c_NANCSNG , coN ': AZ.41POING YOUR N�?� � .:' ; OP COMER= ApplAcatton is hereby u to obtain a pe cu the attached addendum (if applicable) standards of all lave regulating constru permits are required for FLICTRICAL, PLO aml*n AFFIDAVIT: I certify that all t wig`. chum is compliance with all F rtab morn, I authorise the above -named Presider Not* I as to Owner and /or Condo Preside: My Ctx4.1aission ricpire :A'OTARY PJ2I.IC, STAT OT: FF.Ca77.1,,.. Y COW,.� ION EXPE ,rr: Oc ". °::. 795. NDED THR OfARY PULIIC UNL Fi EMI TEL NO:305 899 0497 UNICIPALLTIES OF DADE COUNTY RETAIN COPY) © U ': Ioo.co .f/RSr Gf}OlG� (8'6 4 Ao ' Address Address PLOMEING MECHANICAL PAVING FENCE SIG 0 or ga 51)0 4C Estimated Coates R -oo :CE OF COMMENCEMENT AND !OUR FAILURE T' t IMPROVEMENTS TO YOUR PROPERTY (IF YO YOUR LENDER OR AN ATTORNEY uroRn o work and installation as indicated above, an 1fy that all work will be waformed to meat :h this jurisdiction. X understand that sepazat :GNS, PCmLS, ROOFING, and MECHANICAL work. Ling information is accurate and that all wor le laws regulating constructi ©n and zoning :or to do the work state ; • .�. 4b . _. ure of Contractor or Owner -Builder tat ' - '2 - '"92 Not as to Contractor or chrner;B � RIDA. My Commission EXpireS NOTARY ISSI IC, s �'IY CON.NiISSI0A1 EXPIRES: Oct. 15, 199= *NDED THR*OTARY PU IC; INDERW *TE Other ectrical Engineering 4663 P02 C — ! t . ! • . c., , • \\ . t I , t ), N's k 4 ) \ 1 r' 1-; • ,< 1 , ' - –4, — -- sr — - --;•• 0 - C L —/ THIS INSTRUMENT PREPARED BY: JOSEPH A. MARTIN SR - QUALIFIER .,,.rtecUTH ROOFING OF S. FLING 301 N.W. 71 STREET MIAMI, FL. 33150 STATE OF FLORIDA COUNTY CF DADE • Clrrtt &ivc i3 Court • 1•I.mn Cold' odor Addi et 1 . . S'nely (if any) 'Adds els o1ii T elt `e 1tent Qllt lllllrllll Il 11111(1 ft'llrrlll: 1110 un,Ieniyned I1e1nby 1110111)1 y00 11101 ingnovenl0nU will be 1111)110 lo eminin seal p•opn'ly, and in nccoldnnce will' teclion 114.131 of Ilre 11011dn Slnlulnl, Ilia Iollowinq Inlounnlloll 11 t'o'ed 1111114 11011C1 Ur 1 COMMENCFMUII. 2 Q to 95 sr ' -1) rtI S HO ES ,L Uelctiplion of 1'opetly _. /C a .f....... . / ... ..... / 4N1a......rele. Gf LOTS .. . e / Q //%. .... Lem 05 . ...P /.. ...5//0-7/2 5/ SCG 7.//a,./ _ ti c. /D / j //LZ / ... //-/ /?G ...��Uc?�C /D g T PU34/C jZEGI�i�' /�5 4� D��E �UV/y ..9- R E.R.go = e K1 F..... . G- 4 - , � ..r...�.�.rz • /Y U 1 L c»' 00 f O N'f L/I % PEACW - OFF) ..eO..v SP/91• 4 15.1 Uwner 1 .C.7.f,t r' G, - r1,9"/ R e... Ad'linsl /i .24.0 ..5:1 C)wnnl 10e'00 in tilt, of 1110 implovmnnnl F ee Simple lisle 11111'01 (i1 other limn °won') 3EGV,e±' /T// i3,i ..`/A /./. L Addles" ... /. /....SD 5, Antolini oI bond $ la's of per ton within 1110 Sinle of Flo, id', dnupnnled by owner upon whom nolicet or oiler croeumenit may Io solved: CARRUTH ROOFING OF S. FLEX. Name . 301 N.W. STREET" MIAMI, F7-.33150 Addr ell ....................... In edddion to himself, ownst designnles 1110 following pntton l0 lecelvn n copy oI 1110 Lleno''s Notice et pro- vided 111 Sedion 84.061 (21(1(, I loslde Slelulet (rill In n1 Ownet't option). 111l6 •rACI rot, nrCOnO,n • r / 11',y I HERESY CERTIFY that this is a eye copy of the original f' in,this o:fice on ay of A.D. 19 WITNEUS ray hand and. Official Seal. and Any 1r nurua.n' f04-10 J i' J FI=R 51/ 5 x,,974 ,e 7 / f/e , P. CARRUTH ROOFING OF S. FL,INC 301 N.W. 71 STREET MIAMI, FL. 33150 Owner Sworn lo and nr6scribed 601010 me Ibis . dayol � r . I•lola,y Public NOTARY PUBLIC, STATE OF FLORIDA. MY COMMISSION EXPIRES: Oct. 15, 1995. BONDED TIIRU NOTARY PUELIC UNDERWRITERS, 1 PERI IT APPLICATION FOR MUNICIPALITIES OF DADE COUNTY (OWNER TO RETAIN COPY) Dateizli Job Address 2 (p D Rl. E . 5 sr mom/ SNORI_ ^S Tax Folio ,g �� -� 71 ' �a 5 Legal Descript L p ^ L L • -10- ; i. k 2. 8 h i »'i s !fa ci Permit $ 977 MAR- 18 -'91 MON 12:31 ID:CITY OF P_iu MIAMI TEL NO:305 899 0497 13663 P02 / Lessee / TenantZLialia& � /� ft Owner's Address 2 [ O a_F Q S % w ti / Sb`d16 Contracting Co.pAR'h'UTlr ROog o ' . 1.- Address Qualifier t /9 State. ni ' Oft z Ob "'5 Competency# Architect/Engineer Sending Company Mortgagor 4 Si _"`ature _ofd • er nn . r Condo President Dates 4/ Not *' es to Owner and /or Condo President My Commission Expires : NOTARY PU'3 Uc, .:7.,:.,.-7.z.:, Or FLORIDA. * * * 1 l ;Y' c01 jn: [ t? % 7L I %I 'TER �pNDED THi: r'0 "i.l' ?Z_., (:NDERu k,'TE$ PERMIT Lam: APPROVED: Fire Zoning Mechanical cis 's . /q 9 / /VA Phone 75/ - $b?$ ss# / Phone '76/ 2 S9 Y O V IAS co.F !(�S� Gr'}0/G, T8`6 Q, Address Address Address Permit Type (circle one): (BIIILD N ELECTRICAL PLVMBING MECHANICAL PAVING FENCE S WORT DESCRIPTION 4:=75R OFF - A . R04F rWTt. 5'h-T cP F Tt?dQr6.4P'' � 7,AG- Fe-AX/INP CS t 9 i, Pl v l d OF , AA L'r s g_ I d v FR nl/,l' w/_51# c PAAjek 8 091'4 50 6 rt i.,91P'1/1/4( f'2o - i rM8 C.4 Ar7 SuaiWCIL Square Ft. 20• Estimated Cost or R3Sp. - WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMEMCEMENT AND YOUR FAILURE DO SO MAY RESULT IN YOUR PAYING TWICE: FOR IMPROVEMENTS TO YOUR PROPERTY (IF Y INTEND TO OBTAIN FINANCING, CONSULT wITN YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OP .C). Application is hereby made to obtain a permit:to do work and installation as indicated above, on the attached addendum (if applicable). I'certify that all work will be performed to meet standards of all lays regulating constructioya in this jurisdiction. I understand that separ: permits are required for ELECTRICAL, =SMUG, SIGNS, POOLS, ROOFING; and MECHANICAL work. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all we will be done in compliance with all app.Licable laws regulating construction and zonir Further:110m, 'I authorise the above -named coxltractor to do the work stated. urs of Contractor or Owner- Builder ts: Not ' as to Contract uTAKy PUBi�CrSi`A1'1rQ URID My Commission Exp ires �y COMMISSION EXPIRES: Oct. 15, 1 * * * *NDED TIIR *OTARY PU*C}1NDERW . BuiL'iing - Q`1 1/ l (�✓ Flu:aping -.....__ 1 _ >.• '9, Other Electrical Engineering PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date k 0 b Job Address 2-Go Ci 1 5 Tax Folio Legal Description Square Ft. FEES: PERMIT % c 9 Owner/Lessee / Tenant Owner's Address Contracting Co. c b b. S v v iv Qualifier 0/(c' ' -� ' T c2 .o o'd State # D S -Sf Municipal # Architect/Engineer Bonding Company Mortgagor Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING AVING FENCE _ SIGN WORK DESCRIPTION ( � ' .L Q A f —pP 6 Iv JV E E. C c9 7' 11�, a cro 90ICA r 1' 5 'ar RADON ( , \l� oo Signature of owner and/or Condo Press dent Date 47 ‘" 40 , Notary as to Owner and/or Condo President My Commission Expires: Dai - t res APPROVED: Zoning Building 44/45 tft Historically Designated: Yes No Address Address Address Phone Address R 'IQ 1" s i ss# Competency # 1 W Estimated Cost (value) C.C.F. ' 6 NOTARY 0 — Electrical Master Permit # 19 ST /1/di BOND Phone Signature of Contractor or Owner- Builder Notary as to Contractor or Owner- Builder My Commission Expires: Ins. Co. WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF' YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) AppEcation is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating nstruction and zoning. Kurthennore, I authorize the above -named contractor to do the work stated. TOTAL DUE ork-1-04 Ps oys Date Date Mechanical Plumbing Structural Engineer 123.01 -78 9/96 Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. Contractor's Name: 1 b b p R o-p 47/ Job Address: ROOF CATEGORY ❑ (Low Slope Application) ❑ (Nail -On Tile) ortar- Adhesive Set Tile) ❑ (Asphalt/Fiberglass Shingles) ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other) ROOF TYPE ❑ New Roof ❑ Re roofing ❑ Recovering fki R ❑ Maintenance Flat Roof Area (ft Sloped Roof Area (ft P ;, Total (ft J Master Permit No. Exposure category (per ASCE 7 -88):/V Building Classification category (per ASCE 7 -88 table 1) Ft. A V Ft. A V Deck type: ATTACHMENT Fastener Type: Field: SPACING Perimeter: Corner: DETAIL 1 & 2 ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed) r r r r r r ROOF PLAN Page -1 Appendix "E" �.. UNIFORM ROOFING PERMIT APPLICATION PROCESS No. MEAN HEIGHT1 Deck type: t LA z Underlayment: Insulation: 12" ROOF SLOPE D E T A I . L 3 SLOPED SYSTEM DESCRIPTION 1 `' Fastener type & spacing: Cap Sheet: Roof CC overing: Ai Drip edge: ... )1.&1/4k 4 1 acrd R,eLL ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals (Pmaxl: x A, (Aerodynamic Multiplier): ) - M (Pmax2: X X (Aerodynamic Multiplier): ) - M (Pmax3: x a, (Aerodynamic Multiplier): ) - M TILE CALCULATIONS = M = M = M Page -2 PCA: PCA: PCA: Page -2 Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. Ridge Ventilation? • V " MEAN HEIGHT/ S Deck type: l 17 1° 2i Underlayntent: Insulation: 12" ROOF SLOPE - D E T A I L 3 SLOPED SYSTEM DESCRIPTION I'S� 3 0 1 v -70( Fastener type & spacing: Cap Sheet: Roof Covering: Drip edge: LA, d ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals r \\ TILE CALCULATIONS (Pmaxl: x X (Aerodynamic Multiplier): ) - M = M PCA: (Pmax2: X X (Aerodynamic Multiplier): ) - M = M PCA: (Pmax3: X X (Aerodynamic Multiplier): ) g . = M PCA: . , .\ APPENDIX "F" REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS As it pertains to this Appendix "F ", it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, to provide the owner with this appendix and to explain to the owner the content of this form. The provisions of Chapter 34 of the South Florida Building Code (SFBC) govern all the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained. Aesthetics-Workmanship: The workmanship provisions of Chapter 34 are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between * the owner and the contractor. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 29 of the SFBC. (The roof deck is usually concealed prior to removing the existing roof system) • Common Roofs: Common roofs are those which have no visible delineation between neighboring un is (i.e. townhouses, condominiums, etc.). In buildings with common roofs! the roofing contractor and /or owner should notify the occupants of adjacent units of roofing work to be performed. h Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be vie% ed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The SFBC provides the option of maintaining this appearance. 5. Ponding Water: The current roof system and /or deck of the building may not drain well and may ca se water to pond (accumulate). in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. ®� G. Overflow Scuppers (wall outlets): k is required that rainwater flow off so that the roof is not ove rloaded from 'a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance w'th Chapter 23 of the SFBC. ' Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It ma• be beneficial to consider additional venting which can result in extending the service life of the roof. S The owner may contact the Miami -Dade County Consumer Services Department for further information regarding the above. i n, er's /Agent's Signature - Dat Contractor's Signature Date Time Type Insp'n Permit No. P. 01' / "L3 3 Approved MIAMI SHORES VILLAGE BUILDING DEPARTMENT 305- 795 -2204 Building Inspection Request alL//i Name 1� / Address c Le- , 0 NE Compan a_/1 , . tna, '� Phone # ,93,3 !.� �,3 - ` 53 For Inspector /Namea? d- 3 0c2... �� Correction ❑ Re- Insp'n Fee ❑