Loading...
PLANSR6 /2 ?S• N 95 11/144°/&1_51/ae fiZsmg PAr/o ,41Your r NT" ro F/a0A wv0.6910.44.04061 14( a,rop • 6igePert,c reps or/ R:94seiS heTsw 15 bcoks WOOD APPLICATIONS U UP TO 59.5 PSF U UP TO 71.5 PSF U UP TO 81.5 PSF U UP TO 91.-s PSF CONNECTION TYPE C CONNECTION TYPE C CONNECTION TYPE C CONNECTION TYPE ANCHOR TYPE D DIA. S SPAN A A ! B I C I D I E A A I 8 1 C 1 0 1 E A A I B I C D I E A A I 6 I C D ! E l ` i 6 ff BRASS WOOD BUSHING i 1/a -20 8 63 SPAN 1 1 i3 5 13 13 1 12 12 5 . 12 12 1 10 7 4 10 10 c c 4 L 6 7 88' SPAN S = 4- _ - _ _ 6 1/4 8 6s' sPAN 1 16 i3 8 13 13 1 15 i3 6 13 13 1 88 SPAN 105 SPAN ' 1 SPAN - L 4 6 $/16 B 68 1 16 13 10 13 13 1 16 • 13 8 13 13 1 16 10 7 13 i3 1 14 7 6 9 11 BB SPAN 105 SPAN . 124" SPAN _ ___'"_ _ 4j ' „`,•, ,, 6 3/8" 8 68 - SPAN 1 16 13 11 13 13 1 16 13 9 • 13 13 1 16 12 8 : 13 13 1 16 - 7 • 11 13 88" SPAT! 1 toy SPAN 1 124' SPAN 1 • ....�. = ._._ . t 1 7116 8 68 SPAN - 16 13 12 13 13 1 16 13 10 13 13 1 16 13 9 13 13 1 16 9 8 12 13 88 SPAN 1 105 SPAN 1 = - _ " == -- - 124 SPAN - REV, 1 1 /a" E 1 ,1 1 -T,I Ir1tI rC = 1 1/4" 8 68 SPAN 1 16 13 8 13 13 1 15 13 6 13 13 1 14 : : 9 6 1 13 : 13 1 12 : 6 : 5 8 9 88" SPAN 1 SPAN i __ _ _ -- - -_ - -- -' _ __ - 2 SPAN 1 rr„y. ‘ } 6 1/4 8 68 SPAN 1 16 13 8 13 13 1 15 13 6 13 13 1 14 ± 88 SPAN 1 105" SPAN o � = = -- - = SPAN - = - - VERIOUS HEAD TYPES 6 1/4 8 68" SPAN 1 16 13 8 13 13 1 15 13 6 13 1 13 1 14 9 9 6 6 13 13 1 12 6 6 5 8 9 88 SPAN 1 ■ - 1M,..S.Z,i. all aLM.r 1 105" SPAN = _ 1 124- SPAN 1 � . Y C H O R NOTES: SPANS AND LOADS SHOWN N T}-IS SCI-EDUL E ARE FOR DETERMINING ANCHOR SPACING ONLY. FOR ALLOWABLE SPANS VS. DESIGN LOADS RE ?r TO SHEET 4. W1-iEIJ ANCHORING TO WOOD, THE WOOD MUST BE A MINIMUM 2 X 4 EQUAL TO 12 SOUTHERN PINE 0.55 SPECIFIC GRAVITY • AND STRUCTURALLY PART OF THE FRAMING STRUCTURE OR SUCURELY ATTACHED TO FRAMING STRUCTURE SHADED AREAS REPRESENT ANCHOR CONDITIONS THAT ARE NOT ACCEPTABLE. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE SOUNDNESS OF THE STRUCTURE TO WITH STAND THE ADDIT7ON4L LOADS AND INSURE PROPER ANCHORAGE. SHUT l LR SYSTEM MAY BE INTSALL INTO WOOD, CONCRETE OR MASONRY. S C H E D U L E RDBER`P, S. MO NSOUR, PE EB- 0006024 P!i'81S ENGIIi IZIt1G. Inc PRODUCT REVISED 23 con] ptyiag with the Florida Raiding Code Acceptance No 0 / ad -. 07 Date 03 /7 -72 o0 6 BY I• . r M •• Dade j . Dhisfoa REVISIONS 08/14/98 01/17/01 BY SP SP 7 0t /10/98 SHOWN 98001 7 E EPAIRB /7544 • C .N. - ,_ • 2 t o pa G z 4AG js'P%li t NizfEVJ 9' Fk 1�v4 ryPtc -.1 tl. C00` 'C 2.� • isr /N6 $grcx w1y 4' rrrxrr, 1.e' 6 S O.4 of • —v.: �` 1!. dL cq.. ^ 1 : C - 1 0!N '13.32' • t /2° ?s. ....." LEGEND _3 0U C CL ENCR I Et 1 0.3G 'L • �" --- DENOTES W000 FENCE ' X WIRE FENCE 0 O R M NAIL PROPERTY CORNER RECORD FIELD MEASURED CALCULATED CLEAR ENCROACHMENT CENTERLINE EXISTING CONCRETE PROPERTY LINE c -) T I . 13. S h 6 cv 1.0 (ii r 0 IHEREBY C FORTH BY ADMUMSTRA SIGNED 1L'r. I ` y �r �il�� ° trick �A U , / 6 e `2° 1,111 6 ■ tCO. c0 u 0 ID�.OFF REGISTERED LAND SURVEYOR NO. 3411 STATE OF FLORIDA G" T THIS BOUNDARY SURVEY MEETS THE MINIMUM TECHNICAL STANDARDS AS SET A DAR'D OF PROFESSIONAL LAND SURVEYORS IN CHAPTER 21HH -6 FLORIDA TO SECTION 472027. FLORIDA STATUTES. '112.82. : t i % A.1 r r { • N OTES t) B EARINGS SHOWN ARE EITHER. ASSUMED OR PER PLAT. 2) LE GAL DESCRIPTION PROVIDED BY OTHERS. T HE LAND SHOWN HEREON WERE NOT ABSTRACTED FOR EASEMENT �) OR OTHER RECORDED ENCUMBRANCES NOT SHOWN ON THE PLAT. `) UNDERGROUND WERE NOT L OFFFOOTPIGS. FOUNDATIONS OR OTHER 5) ELEVATIONS ARE BASED ON NATIONAL GEODETIC DATUM. 6) FENCE OWNERSHIP NOT DETERMINED. 7) WALL TIES ARE TO THE FACE OF THE WALL. 8) NOT VALID UNLESS SEALED WITH AN EMBOSSED SURVEYORS SEAL 9) ONLY VISIBLE ENCROACHMENTS LOCATED. ]] iIiI - T r - ) 1 - r=-sjf • w I_ a I - i• I -I.•- 16;:..41 A• R 1) _ - I +~- �) -1 •.1. - -' .._ -r4 L,. - Ill i i c = ° Legal Description Community number. 120652 Panel: 0093 Suffix: G Date of F.I.RM: 1/20/93 Date of field work: 7/16/93 Completion date: 7/20/93 Flood zone: AE Base flood elevation: 8.00 Adjacent grade: 6.43 Lowest floor elevation: 8.21 Survey number. G -2395 Property address: 1286 N.E. 95 Street Miami Shores. Florida 33138 uI• KI.. 1. nq ,� seat First Financial Surveyors, Inc. 4 1' y _ e. -- I r eo f . • Ln • • 1» %? 1-za,c ;c) Y-A Lots 3 and 4. Block 85. of MIAMI SHORES SECTION i YRREE. according to the Plat thereof. recorded in Plat Book 10. Page 374. of the Public Records of Dade County. Florida. Certified to: Robert G. Barris and Veronica Barris: First Financial) Title Company of Florida; Ticor Title Insurance Company; Colonial Mo);Ugage Company. its successors and /or assigns. • 7700 North Kendall Drive Suite 409 - Miami.Florida 33156 (305) 211 -3655 Fax (305) 271 -8499 800 -227 -2854 Fax 800 - 227 -2860 AND AFFILIATED COMPANIES 564r11.1b • N • 1 opTtauk. ^^ HILL LB " f2 04- a l�.►l 0k__ Ma' (► )C �a'► 25 ' _'T!0l - 1/2 ° i • a o • • • • 4 (r° 47TV:!:!:1 1C:N 0":::!OTSIC‘', 11V EFL 63;fialti *r.sli:(27‘4 z qi AE 3C G3 a:;!Irrtir.::: 11 Si4trid 3H1 Sfl1S3 sois ArigUitTii L'W . • —• -,t. NolD J „ e U . ■;• 111 1i it --- 1 _ IL — V -------- riViOiAe.j.D37.'; , J! I 1; T Abi ; '`-) ut eti IT !ai.:1.37.1 ANCHOR SPACING vs DESIGN PRESSURE AND CONNECTION TYPE 8" 5 P----c-P 01 4 PEP =-- E_ :c' : -E_ - E C::NCPET= E_:•C< POUPEDC:o =E- I .Z. _;=- E_CCr. :a 7 I coNNEC ?C: T• CCucEC -, c. , : -•== I C : , E :1Cu - ,-;•- - E ANCHOR TYPE PANEL E.D. 5 r C D I E I A , 5 I C D I E .. I E I C I D I E I A 6 i 1 I E 68 3 6 13 B 13 13 16 ' 13 9 13 13 16 12 6 13 : 13 16 • 12 • 7 12 13 16 11 5 13 • 13 16 11 • 6 13 13 16 9 8 ' 12 13 : 16 9 9 12 : 13 16 ' B 7 11 13 ; 16 8 . 7 - 11 : 13 15 7 5 10 11 [ 15 7 E 10 11 2 � - di r H I 3 1 1/4- 1/4- SLEEVE ANCHOR 1 1/4 MIN. EMBEDMENT SB Span 3 16 6 6 B 7 16 6 7 B 7 14 5 5 7 6 ,..14......5...:.. 6.......!.... ..6.... 13 5 4 6 5 • 13 5 : 5 6 . 5 14 5 5 6 5 14 5 6 6 5 13 4 4 5 4 4 5 5 4 13 11 4 4 5 4 I 11 . 4 4 5 2 1 " 4- 105 Span 3 - - --- - --- - -._...- -- _ - _ -- =- _-= - - - - - --- -- ..__._._�__ ---- --- -- ___.__.._.._... - -_' _- -- - _ -- --- - _ - - - - -" -_ "- - .. .::l.:_:_..= �:': ::- _:_::::._= _— :_ _.::- . 2 g ' 68' Span 3 16 11 7 13 13 13 8 6 : 12 13 15 10 : 6 13 13 11 7 5 : 11 11 14 9 5 13 13 10 6 4 9 10 15 7 7 . 10 12 ! 11 : 5 6 : 7 : 9 13 6 5 . 9 10 10 - 5 5 12 6 4 8 9 .9 4 4 6 7 2' C 11I I .1 1/4 fl i 1 /4 SLEEVED DRIVE ANCHOR 1 3/8 MIN. EMBEDMENT 88 Span ' 13 5 5 7 6 i 10 4 4 5 4 12 4 5 6 5 9 3 4 4 4 10 4 4 5 4 6 3 3 4 3 12 4 5 5 10 3 4 4 9 3 3 4 4 ! 9 - 4 4 . 3 2 3 8 - -. 3 3 -- __ 7 : : is :: " = 3 --= 3 -V- ' - " 105 Span ..•....".-._. r =r: ..ter = ._.. - -- _ - 1 2- 1/4' ZAMAC HAMMER DRIVE 1 . MIN. EMBEDMENT • _ - _ .:_: :__ .______..__._._._ _ __ _ _ — _ __ _ -_ ___ _ __ — ___ - _ _ _ __ _ _ _.._.. ..__.._ __ __ _ -_ _ __ 4 _ VARIOUS HEAD TYPES 68 Span 3 16 13 11 13 13 ; 15 10 7 13 13 16 13 9 13 13 1 14 9 5 13 13 16 13 7 13 13 12 8 4 11 12 16 11 10 13 13 ■ 14 7 6 9 11 16 10 8 13 13 112 6 5 8 9 16 9 7 12 13 '• 11 5 4 7 8 2 1/4 88 Span 3 16 B 9 : 10 9 I 12 4 5 6 5 16 7 7 9 8 i 10 4 4 5 4 16 6 6 8 7 t 9 4 3 5 4 16 6 B 8 6 I 11 3 5 5 3 16 5 6 7 5 i 9 3 4 4 3 15 5 5 6 5 18 3 3 4 3 5 al VS-r '>.i,S1ITU% EV, FrY, 'r°-'_'_ 4' 1 1 }l;_a_,aii: }it.,Lr�% 1 r 1 1 1 i - V Y SCREWS MASONRY MIN. EMBEDMENT 2' i 1 /a- 1 o5" Spar 3- ,..:::::.•:. - - _ - _ - - - 2 724' Span .... :. _._ .• .., ..__. - _ :.:e r_: »._:C•' -- __... .: ._..._. .__. _.. ._._ _. -c —: _..- ._.. :..__..__ ...___.: _r_cs- �.::�_. ____: .:.-rte_. - -:c_: =._.: ... _. -P . _: _: �..�.:'= -_. _.._.. _.._.. _.. - _,:_ems:.._ - - - ._ _ —_. -.. �.c: —. _. _... ___._..., ....__.._...._._._ . 1 / 68" Span 3 - 16 .: 13 12 13 13 ; 15 10 7 13 13 13 1 14 9 6 13 13 13 12 8 5 11 12 16 13 11 13 13 t 14 7 6 9 11 16 12 9 13 13 112 6 5 8 9 16 11 7 13 13 1 11 5 4 7 8 2.5 16 13 10 13 2 13 B 13 8S Span dlingirP 9 9 13 11 i 12 4 5 6 5 g 11 4 4 5 4 8 •! 9 4 4 5 4 16 7 8 10 7 11 3 5 5 3 16 7 7 9 6 i 9 3 i 4 4 3 16 : 6 5 8 6 1 8 3 : 3 4 3 1/4 - 20 x 7/8 . 112 DIA. MACHINE SCREW ANCHOR 7 /8" MIN. EMBEDMENT a.5 16 8 8 11 2 16 8 6 10 105 Span ._._...._........., ........ ....... 3• -....- ........_ ._....... ..____.. _.......,.....__::-:::::.::: :::_::..,_.__: :..__.::__._..... .. 1-, . _.. _...___. _..........._ . "...-'--'--..._..._..._.. is .: -.:- :.- ..._._... :.:-- .:. —u_:: 2.5' • A N C H O R S C H E D U L E t, J c. /l/ 4/67/1k 7(7 ROBERT • 1402v PE EB- 006024 2/T f11GINE"- 211i'3.11iC NOTES: SPANS AND LOADS SHOWN N TI-IS SCHEDULE ARE FOR DETERMNNG ANCHOR SPACING ONLY. FOR ALLOWABLE SPANS VS. DESIGN LOADS REFER TO SFEET 4. MINIMUM. ENBEDMENT AND EDGE DISTANCE EXCLUDES STUCCO AND /OR WALL FiNISHES. SHADED AREAS REPRESENT ANCHOR CONDITIONS THAT ARE NOT ACCEPTABLE. IT SHALL BE THE RESPONSIBILITY OF THE CONTrRACT R TO SOUNDNESS r VERIFY THE N N C t ESUD SSr D 0 c THE S TO WITH STAND THE ADDITIONAL LOADS AND INSURE PROPER ANCHORAGE. SHU;I SYSTEM BE �, Y _7 S .. tJ, IAAY INTSALL INTO WOOD, � N - S•�LL N CONCRETE R MASONRY. O ✓ .50VRY. PRODUCT REVISED as complying ia 8 w its the Florida Ba' ldln 8 Code AcceptaaceNoo1 -/22 Ezpiratioa Date _ By ,� , . [/,��- Miami Dade act Coatr>Qi Dirision .6 1■• REVISIONS BY 03/20/ 98Isp 06/12/98 sP 08/14/98 sP 01/17/01 ran sE/ JRS 1R su D1 /10/ 8 SHOWN 9800 MaT SP 1 ANCHOR SPACING vs DESIGN PRESSURE AND CONNECTION TYPE 50 p5= 71.5 PSF =__ -E Ca., =E- c ::c =E-E BLOC -C REO„_, C -_— I - _ _ __ __•r:EC " =.';'=E I C Cr1 :15.7 7:0r1 -r ^E CCrr.IEC7c.: -.. E .:;-: ^, =E ANCHOR TYPE PANEL I E.D. A I 8 IC ID I E I I 6 I C ID I E 15 13 11 13 13 . 16 13 13 13 13 15 : 13 9 13 13 : 16 13 10 13 13 _ 15 • 13 7 13 13 16 . 13 5 13 13 A I 6 I C 10 J I E 14 I 6 C ID E 68" Span 3 16 13 9 13 13 16 13 11 13 13 16 13 7 13 13 ' 16 13 9 13 13 16 13 6 13 13 7 16 13 7 13 13 2 ill ' 1 I I — Ira SLEEVE ANCHOR 1 1/4 MIN. EMBEDMENT es" Span 3 16 - 13 8 13 13 : 16 13 10 13 13 16 ' 13 ' 7 13 13 16 13 5 13 13 15 13 5 13 13 16 . 13 6 13 13 16 8 7 12 13 16 9 8 12 13 16 8 6 10 12 16 8 7 11 12 15 7 5 9 10 15 7 5 9 11 2 / 105" Span - 15 : 9 i 12 13 16 9 8 12 13 16 8 6 11 12 16 8 7 . 11 12 15 7 5 10 11 16 7 • 5 10 . 11 . 15 5 7 ' 15 5 7 7 6 14 - .5.... S : 12 : 4 4 6 5 ; .14. 2 : 4 4 6 5 2- ' 1J4_ 124" Span 3" 15 : 5 o 7 6 15 5 7 7 6 14 5 5 6 5 4 12 4 4 6 5 12 4 . 4 6 5 = - -_ _ . ._ �_:._r:_, =' ' =•`_.._..r_...,.:__:.:_:_,_ 2 .• -- - ';'F,,,. � _ =_ =' r 68" Span 3- 16 13 10 13 : 13 t 16 13 : 8 13 13 16 1 3 ' 7 : 13 : 1 3 115 13 . .. 13 • 13 16 13 : 6 13 13 1 14 13 . 6 : 13 13 16 : 13 8 13 : 13 14 13 7 13 13 16 : 13 7 13 : 13 ; 13 13 6 13 13 15 : 13 6 13 : 13 ' 12 12 : 5 12 : 12 2" IIII p 11 /4- J � � — ll 1/4 SLEEVED DRIVE ANCHOR 1 3/9" MIN. EMBEDMENT r 88'. Span 3 16 ; 13 8 : 13 13 : 13 10 6 13 • 13 12 16 I 12 6 : 13 : 13 1 . 12 9 5 1 .. ' 12 . _. 14 : 11 5 13 13 : 11 8 4 11 11 15 7 6 10 11 I 11 5 5 7 13 6 9 10 : 10 - 5 : 4 6 ' 7 12 6 4 8 9 9 4 4 6 ' 6 2' t 114- 105" Span 3 15 7 6 ' 10 : 11 : 11 5 5 7 8 13 6 5 . 9 10 ; 10 5 4 7 7 12 6 -- 4 8 9 9 4 4 5 7 13 4 6 • 6 5 ■ 9 3 4 4 3 11 4 4 - 5 4 8 3 4 4 3 7 ...... _- 10 4 4 5 4 7 3 3 4 3 ® i 2" 1/4 ZAMAC HAMMER DRIVE 1 3 /8" MIN. EMBEDMENT 114" 124" Span 3 13 4 5 6 4 4 5 3 3 4 4 5 4 4 4 8 3 3 10 4 4 5 - 4 7 r 3 3 4 3 - _ - - - - - _ - ' - - - - - - - - -' -- __ -_ -' __ - - - - - - - - ' -- - - 13 7 ::.r 13 6 13 5 - - - -- -'_ - - -_ 2" 1 / 4- • VARIOUS HEAD TYPES 68" Span 3 16 13 - 13 : 13 : 13 16 13 _ 9 13 13 16 13 12 • 13 13 16 13 7 13 13 16 13 10 13 13 16 13 6 13 13 16 13 13 13 13 ; 16 16 13 10 13 13 15 16 13 8 13 13 : 14 13 13 13 _ 13 12 13 2" 1 1/4 V. 4Li,1 - 1Sra 1 \. 1.1 % 88" Span 3 16 13 12 13 13 16 12 7 13 13 16 13 10 13 13 ': 14 11 6 13 13 16 13 8 13 13 I 13 10 5 13 13 16 11 10 13 13 i 13 6 6 9 10 16 10 8 13 13 i 12 6 5 8 9 16 9 7 12 13 ! 11 5 4 7 8 2 1'ci1d I_ alWal41.X 1 1,4- -rl �� f ���� Ifl t i � } � 1iFl � 1/4 MASONRY SCREWS 1 1 IN EMBEDMENT /2 MIN. 705' Span 3 16 11 10 13 13 13 6 6 9 10 16 10 8 13 13 : 12 6 5 8 9 16 9 7 12 13 : 11 5 4 7 8 16 7 8 9 7 I 11 4 5 5 4 16 6 7 8 6 10 4 4 5 16 : 6 5 7 6 19 3 3 : 4 3 2 1 1/4 - 1 24" Span 3 16 7 8 : 9 7 : 11 4 : 5 5 4 16 6 7 8 6 2 10 4 4 5 4 6 6 7 6 ! 9 3 • 3 - _ - - - _ - ' -= -- -- - - - -- -- - - - - - - - - ... ...... ....................._ _.. .._.. __.. 2" 68 Span 16 13 13 13 13 : 16 13 9 .13 13 16 13 13 13 13 16 13 8 13 13 16 13 11 13 13 16 13 6 13 13 13 13 3 ° 1 .. 16 ...................... .. 13 :...... 1...... 15 13 ........... ....... 16 13 11 13 13 16 13 6 13 13 16 13 9 13 13 14 13 5 13 13 �- 2.5 2- 1/4 - 20 x 7/8" • 1/2" DIA. MACHINE SCREW ANCHOR 7/8" MIN. EMBEDMENT BB" Span 3 16 13 13 13 13 i 16 12 7 _ 13 13 16 13 11 13 13 14 11 6 13 13 16 13 8 13 13 13 10 5 13 13 16 13 11 13 : 13 13 6 5 9 10 16 12 9 13 : 13 12 6 5 8 9 16 11 7 13 : 13 i 11 5 4 7 8 2.5" 2 105" Span 3 16 13 .. 13 13 . 6 6 9 10 ... .... .... .... . . . .. . ... t3 ......... .. .... ........... ... 16 12 9 13 13 12 6 5 8 9 16 11 7 13 13 11 5 4 7 8 16 8 9 11 ' 9 : 11 4 5 5 4 .. ..... ........ ... .. ........ 16 8 7 10 8 10 4 4 5 4 16 7 6 9 7 9 3 3 4 _ 2.5 2 124 Span 3 16 8 9 11 1 9 i1 4 5 5 4 16 10 - -= - - -- _ __ - _ _ - _ — _ _ - - • - - - = - -- >: � -: may_ = A- :.. 2.S" 2" - .... - --- - -- - _ -'� ;:: .:_-::: A N C H O R Jt`• S C H E D U L E r1 V / ROBERT S_ TONSOUR, PE EB-- 000602` ea< t9 EHG nEFIHG, InC NOTES: SPANS AND LOADS SHOWN N - VHS SC1-EDLLE ARE FOR DE EERMNNG ANCHOR SPACNG ONLY. FOR ALLOWABLE SPANS VS. DESIGN LOADS REFER TO S}ET 4. MINI,YUM. ENBEDL4ENT AND EDGE DISTANCE EXCLUDES STUCCO AND /OR WALL FINISHES. SHADED AREAS REPRESENT ANCHOR CONDITIONS THAT ARE NOT ACCEPTABLE. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE SOUNDNESS OF THE STRUCTURE icO WITH STAND THE ADDITIONAL LOADS AND INSURE PROPER ANCHORAGE. SHUT? i : 1' SYST / MAY BE INTSALL INTO WOOD, CONCRETE OR, MASONRY . PRODUCT REVISED as m=plyizg with tbc Fbridn Bnidiog Code Aeaptance No • — Expiration Date By Miami DadGl'roduct Control Division 03/20/98 06/12/98 08/14 /98 12/15/D0 01/17/01 REVISIONS BY SP SP SP SP SP I U DESIGN PRESSURE PANEL SPAN 21.93 142" 25.57 139" 29.99 136 " 35.36 132" 37.44 130" 39. 10 129 " 40.77 127" 44.40 724" 47.81 123 51.23 779" - 58.06 1 7 7' 1.47 109 " 6.6.85 704" 71.46 100" 75.30 95" 87.45 88" 86.83 82" 91.44 78" PANEL HEIGHT 0 " -90" ' 90" -142" WALL MOUN 2 5 8 3 1/2" I MOUNT — 2 - 37r" 3 1/2" BUILD OUT 2 5 /8" 3 1/2" PANEL HEIGHT I 0" -104" I 104' -142' WALL MOUNT I 2" I 2 1/4" INSIDE MOUNT I 2" 2 1/4" BUILD OUT 2" 2 1/4" 24 ga. S I ttL USE 59.5 P.S.F. COLUMN AND 124" PANEL SPAN ON ANCHOR SCHEDULE FOR ANCHOR SPACING FOR • SPANS OVER 724" 3 8 THE METAL T ECH STORM PANELS MAY BE INSTALLED WITH OR WITHOUT THE HORIZONTAL BRACE STRAP. REFER TO PANEL DEFLECTION CHARTS. 1/4 -20 STUD WITH WINCNUT 12 1/2" O.C. HORIZONTAL BRACE STRAP DETAIL "E" FRONT VIEW SIDE V1EW r 318" (TYP.) 1/8" X 3/4" FLAT ALUMINUM BAR SIDE VIEW FRONT VIEW MAXIMUM GAP BETWEEN PANEL AND HEADER 15 1/4" (TYP.) DETAIL "F" 3, FASTENER MUST BE IN MORROW PORTION OF KEY HOLE, IF NOT A KEY HOLE WASHER SHOULD BE USED MOUNTING HOLE MAY ALSO BE A 9/16" DIA. CIRCLE DL IAIL "G" • 8 142" MAX. PANEL HEIGHT NO PANEL STRAP IS REQUIRED HIGH VOLOCITY HURRICANE ZONE PANEL DEFLECTION CHART WITHOUT HORIZONTAL STRAP MINIMUM DISTANCE BETWEEN GLASS AND PANEL DETAIL 13 ON SHEET 3 DETAIL 1 - , SHE WALL MOUNT ANCHORING PANEL TOP & BOTTOM NO HDR. OR SILL 3/ .125 THICK ..KEY HOLE WASHER DETAIL 3, 4, & 8 ON SHEET 2 DETAIL 3,4, & 8 ON SHEET 2 WALL MOUNT ANCHORING PANEL TOP ct BOTTOM i',7 H STUDDED HDR /SILL 24 GA FIAMfrititri &WALT STEEL STORM PANEL FRONT VIEW SIDE VIEW HEADER AND SILL TYPE MAY VARY, DEPENDING ON APPLICATION DETAIL 1 ON SHEET 2 DETAIL 15 ON SHEET 3 DETAILS 3,4 AND 8 ON SHEET 2 WALL MOUNT WTTH HDR. AND SILL GLASS DETAILS 5,7,9, 1 0 AND 11 ON SHEET 2 TYPICAL SECTION VIEWS HORIZONTAL BRACE STRAP PANELS MAY RUN CONTINUOUS BY WIDTH f G I `� HEADER AND SILL EITHER HORIZONTALLY OF VERTICALLY ROBERT`' . 1,1 NSOUR, PE EXPLODED ASSEMBLY EB-0006024 ,i PR':1S ENGINEERING. INC 142" MAX. PANEL HEIGHT ONE PANEL STRAP LOCATED MIDSPAN HIGH VOLOCITY HURRICANE ZONE PAWL DEFLECTION CHART WITH HORIZONTAL STRAP DETAILS 5,7,9, 10 AND 11 ON SHEET 2 HEADER MINIMUM DISTANCE BETWEEN GLASS AND PANEL \\)1 SILL BUILD OUT WITH HDR. AND SILL GLASS By tviismt Dad Division DETAIL 2 ON SHEET 2 DETAIL 15 ON SHEET 3 INSIDE MOUNT WITH HDR. AND SILL PRODUCT REVISED $, complying 'Mb the Flori,3i Btridlag Code Acceptance No O — 2 Z Expiration Date VI II // j SILL DETAIL 4 ON SHEET 2 07 • AZ's' O0 6 amdi —all .1 r rodact Control R v ST3ks t' 03/20/98 sP 06/12/98 sp 08/14/98 SP 12/04/00 SP 01/17/01 SP 01/11/02 SP 09/09/02 SP 4 7 .a� 1 4 -20 FLOOR PLUG WITH ACHINE SCREW ANCHOR HEADER OR SILL CONCRETE OR MASONRY. ° , CONFECTION TYPE " ' • REFER TO DErEC77ON CHART er STORM PANEL CONFECTION 1/4 -20 FLOOD PLUC WITH 1/4 -20 BRASS WOOD BUSHING HEADER OR SILL INTO WOOD " MIN. CLASS —3/4" MIN. 1 1/4" MAX. DETAIL 15 SEE ANCHOR SCHEDULE CONNECTION TYPE 'B" • DETAIL 21 NOTE: SERVE THRU WINDOW STORM PANEL NOTE' 3/8" THRUBOL TS 9 1/2" 0. C. WITH 2X3X. 125 ANGLE ON BOTTOM WIND PRESSURE 71.5 P.S. F. MAX. MAXIMUM PANEL LENGTH 48" 1 1/4" MAXIMUM THE METAL H STORM. PANEL M.4Y BE INSTALLED WITHOUT 77-1E USE 0- AN EXTRUDED HEADER OR SILL. THE SH ' t MAY BE ANCHORED DIRECTLY TO THE STRU! RE WITH THE USE OF ONE OR A COMBINATION DETAIL 13 SEE ANCHOR SCHEDULE COteEcnoN TYPE "C" E. DETAIL 16 WOOD COUNTER 1 1/4" MAX. THICKNESS COUNTER MAY BE MADE OF OTHER MATERIAL SEE ANCHOR SCEDULE FOR ANCHOR TYPES ALL ANCHORS 12" 0.C. NOTE* x z m DETAIL 17 NOTE 1/4 PANEL MATS SCREW W177-I 14 -20 s WITH WASHERED WNGNUT • HEADER OR SILL WOOD, CONCRE i c OR MASONRY e O' CONNECTION TYPE "A" 1/4 " PANEL MATE WITH MACHINE SCREW HEAD WITH 14 -20 SIDEWALK BOLT HEADER OR SILL or HEADER or SILL SEE ANCHOR SCHEDULE CONNECTION TYPE "A" WOOD, CONCRETE OR MASONRY O O or® HEADER or SILL SCREWED OR BOLTED TOGETHER 477Y, 1/4 -20 THRU BOLT W/ LOCK NUT 12" O.C. RO CONTINUOUS BLOCKING 1/4" ANGLE DETAIL 22 ADJUSTABLE HEADER OR SILL REFER TO DEFECTION CHART CUSS 1�IX STORM PANEL TION TYPE "A" HEADER or SILL NOt SEE' ANCHOR SCHEDULE CONNECTION TYPE "C" DETAIL 18 1/4 -20 MASHINE SCREW ANCHOR WITH SIDEWALK BOLT OR 1/4 MASONRY SCREW 4. 0.C. 3" MIN. EDGE DISTANCE POURED CONCRETE ONLY 59.5 PSP MAXIMUM / PANEL FEIGHTi 109" hilAXIMUM STUD HEAD . b . PANEL SECURED h' Y// —' WASHERED W1WCNUTS STUCCO FINISH REFE7? TO DEFECTION CHART �r= STORM PANEL DETAIL 19 NOTE: ( s / //7 A ROBERT 3. MONSOIJR, PE EB- 0006024 etr•s ateln- -mRIrr, Inc SEE ANCHOR SCHEDULE CONNECTION TYPE "A" NOTE* _ P €CT1ON TYPE "A" HEADER or SILL DETAIL 14 GLASS CONFECTIONS 'TYPE "A" IF t� STUCCO INSTALLATION 1/4 -20 MACHINE SCt W ANCHOR 1.125 DIA MOLDED NYLON CAP 1/4 -20 M/S FLOOR PLUC 5 /6' STANDARD 1" MAIL DETAIL 20 /T SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE SOUNDNESS OF THE STRUCTURE TO WITH STAND THE ADDITIONAL LOADS AND INSURE PROPER ANCHORAGE. SHUTTER SYSTEM MAY BE INTSALL INTO WOOD, CONCRETE. MASONRY. WHEN ANCHORING TO WOOD, THE WOOD MUST BE A MINIMUM 2 X 4 EQUAL TO /2 SOUTHERN PINE WITH 0.55 SPECIFIC GRAVITY .L,ND STRUCTURALLY PART OF 7745 FRAMING STRUCTURE OR SUCUREL ATTACHED TO FRAMING STRUCTURE PRODUCT REVISED as complying with doe Florida Raiding Code Acceptance NoO i 07 Expi tioa Date ah'W op 1 P 4.4111111, i By Miami D Division c Product Coatro! 1.25 DIA E TRUDED ALL /MINA TUBE .062 WALL THICKNESS REVISIONS H1� 03/20/98 sP 04/20/98 SP 06/12/98 SP 08/14/98 SP 01/17/01 SP 01/11/02 SP 98001 3 7 • NOTE * NOTE* A DETAIL 1 E.D. • :NOTE* OBSTRUCTION SEE ANCHOR SCHEDULE CONNECTION TYPE "B .500 EO EO SEE ANCHOR SCHEDULE CONNECTION TYPE "D" HEADER or SILL FLOOR PLUG AND MACHINE SCREW ANCHOR 12" D.C. STORM PANE. (TYP.) HEADER or SILL DETAIL 5 SEE ANCHOR SCHEDULE 500 CONNECTION TYPE "B" DETAIL 9 SPECIAL PANEL CONFIGURATION MAY BE NEEDED FOR TRAPPED WIDTHS. PANELS MAY BE ADDED TO WITH A MAXIMUM ADD —ON OF 3' FASTENED TO PANEL BY THE USE OF /54 POP RIVETS 3/16" TUBULAR RIVETS OR 10 -24 1 RU BOLTS 16' D.C. CORNER PAN ANGLE MAY VARY R 19 FLANGE MAY BE REVERSED OR OTHER HEADER or SILL REFER TO THAT APPLICATION FOR PROPER CONNECTION TYPE CONTINUOUS BLOCKING 2 PIECES FASTEN TOGETHER WITH #64 RIVETS OR /8 TECK SCREWS 12' O.C. �c 1/4 -20 THRU BOLT W/ LOCK NUT 12" O.C. RETURN PAN, ANGLE TUBE OR WOOD MUST BE USED ON ALL BUILD OUT CONDITIONS TO CLOSE OFF ENDS RETURN PAN VARIOUS SIZES 1/6 X 1 1/2 FLAT BAR SILL STUDDED WITH WINGNUTS PLAN VIEWS DETAIL 12 A, B, C A D SEE ANCHOR SCHEDULE CONNECTION TYPE "C" DETAIL 2 ED...: NOTE* SLOTTED MOUNTING HOLE MAY BE USED IN CENTER WEB OF PANEL. TYP. FOR ALL SPECIAL PAN APPUCiTIONS. L 7" MIN. SEE ANCHOR SCHEDULE CONNECTION TYPE "E" DETAIL 6 NO#EE* 7 5/8 MAX. 7t5 PSF MAXIMUM Q MAW4L1 PANEL WIGHT aS ".' DETAIL 10 O HEADER ON TOP SILL ON BOTTOM 1/4-20 x 3/4 KNURLED STUDS WITH WASHETED WINGNUTS (TTY'.) OR. 1/4 -20 RIV TNUT WITH 1/4 -20 FLOOR PLUG (TYP.) DETAIL 3 FLOOR PLUG AND MACHINE SCREW ANCHOR 12' O.C. INSIDE. CLOSER PAN ASSEMBLY/ I CLOSER PAN HANDLE SEE ANCHOR SCHEDULE CONNECTION TYPE "A" RO HEADER or SILL MAY BE INSTALLED IN REVE DIRECTION OR O CONTINUOUS BLOCKING 3/16 ANGLE BOLTED TOGETHER WITH 1/4 -20 THRU BOLT W/ LOCK NUT 6' O.C. USED AS HEADER OR SILL R O HEADER or SILL MAY BE INSTALLED IN REV SE DIRECTON rt AS IN DETAIL 6 0 CONTINUOUS BLOCKING R 3/16 ANGLE BOLTED TOGETHER Y•FN 1/4 -20 THRU BOLT W/ LOCK NUT 6' O.C. USED AS HEADER UR- SILL R O CONTINUOUS BLOCKING 3/16 ANGLE 1/4 -20 MASHINE SCREW ANCHOR WITH SIDEWALK BOLT OR 1/4" MASONRY SCREW 3" D.C. 3; mIN.- EDGE DISTANCE -PQURED• CONCRETE ONLY OP;7ONAL USE OF 1/8" ANGLE FOR PURPOSE OF EXTENDING PALL MAXIMUM GAP BETWEEN STROM PANEL AND D.L.O. SHALL NOT EXCEED 1/4" AS VIEWED FROM FRONT VIEW HEADER or SILL PANEL NOTCHED AT BOTTOM TO PASS OVER STUD AND WINGNUT IN SILL (EACH SIDE) S HEADER or SILL - GA F cG - JJO 7C SEE ANCHOR SCHEDULE CONNECTION TYPE "C" DETAIL 4 9. MAXIMUM SE' ANCHOR SCHEDULE CONNECTION TYPE "A" NOTE: ®or 18 HEAD. or SILL OR OTHER HEADER or SILL REFER TO THAT APPLICATION FOR, PROPER CONNECTiON TYPE CONTINUOUS WOOD BLOCKING VARIOUS SIZES DETAIL 7 y� \ E. D. E. D.\ C L— STORM PANEL IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE SOUNDNESS OF THE STRUCTURE TO WITH STAND THE ADDITIONAL LOADS AND INSURE PROPER ANCHORAGE. SHUTTER SYSTEM MAY BE INTSALL INTO WOOD, CONCRETE, MASONRY. WHEN ANCHORING TO WOOD. THE WOOD MUST BE A MINIMUM 2 X 4 EQUAL TO #2 SOUTHERN PINE WITH 0.55 SPECIFIC GRAVITY AND STRUCTURALLY PART OF THE FRAMING STRUCTURE OR SUCLR=LY ATTACHE TO FRAMING STRUCTURE 1 � �' J •v ^ G1 I I ROBERT S. MONSOUR, EB- 0006024 PA"117 ENO INEEeING, Inc WINDOW OR DOOR DRONING PE 2 3/4 ' MAX. NOTE* M&XI►t ►i PU) CF STORM PANEL HORIZONTAL INSTALLATION ELEVATION DETAIL 11 By Miami Division VERTICAL INSTALLATION ELEVATION SEE ANCHOR SCHEDULE CONNECTION TYPE "B" DETAIL 8 SEE ANCHOR SCHEDULE CONNECTION TYPE "D" R 0 CONTINUOUS BLOCKING BOLTED TOGETHER WITH 1/4 -20 THRU BOLT W/ LOCK NUT 12' O.C. R 18 CONTINUOUS BLOCKING 1/4 -20 x 3/4 KNURLED STUDS WITH WASHERED WINGNUTS 12 1/2' O.C. (TYP.) MAY BE MOUNTED VERTICALLY OR HORIZONTALLY PRODUCT REVISED as complying with the Raids Bolding Code A No / Z - O7 Expi ptance Datr O/ J Z 3 l77T_ D LL/..(/' Product Control R;VS'ONS B" 03/20/98 sP 06/12/98 08/14/98 01/17/01 SP SP SP 2 7 1. 7 -. -J • • C) i*1 FLAT BAR 2 3/8' T 2 VARIOUS DEGREE CORNER PAN .050 MIN. N 7/B' 1 3/32' 3 7/32' 1 3 1/32' 2 1/4' 125 T1 ,3 MOUNTING HOLES 12 1/2" O.C. ROSS SECTIONS .090 2 3/B' 3 7/32' 1 3/32' 7 /B' N N crs Cu ;1 29/32' VARIOUS TYPES OF F —TRACK NOT SHOWN � 1 1/2' RETURN CD \ .060 MIN. 7/8' 1 3/32' 3 7/32' 1, 3/32' VARIES l I 5' MAXIMUM SPECIAL NET PANEL SECTION 3/4' r -- .093 N 0 - 3 ' VARIES M m O � 5 ro .060 MIN. ` BLOCKING STUD MAY BE INTALLED IN REVERSE DIRECTON 77P/CAL 1/ 5 13/16' h C) LIHt Cu wal L3H 1/8" MIN. 2 1/4 L3H 1/8" MIN. 2 rl - O • L1H i /8" MIN. i 1 1/2' l ALL STUDS .3/8' ; ?YP. ) I ALL APPUCAT7DNS ANGLES STUDDED IN 44CLUDES STUDDED T, SHORTER LEG ONLY RE'• 1/4 -20 X 3/4 16 -8 STAINLESS STEEL KNURLED STUDS 12 VT 0.0. TO APPLE:4770MS ON SH STS 2 et 3 ANCHOR MOUNTING IL)L:S LOCATED ON EI7HER HORIZONTAL OR VDMCAL LEG. ® O AND ,9 STUDDED ANGLE DETAIL 7/8" x 1 1/2" FLAT STUDDED STRAP MAY BE USED IN PLACE OF ANGLE GO/ RLIES WITH: FLORIDA BUILDING CODE 2001 TESTED TO TAS207, ThS2C2 AND DESIGN CRITERIA: PRESSURE REOUIREMEWT CALCULATIONS MUST BE PERFORMED PER ASCE 7 "MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" GENERAL NOTES: ALL ALUMINUM EXTRUSIONS TO BE ALLOY 5063 —T6 OR EOUAL STORM PANELS SHALL BE 24 GAUGE STEEL, ASTM A653 SO GRADE E M /N. Fy = 90 K.S.I. MINIMUM VALUE WITH .031 MINIMUM THICKNESS HOT DIP COATED. WITH A NOMINAL WIDTH OF 12 1/2" THE STORM PANEL SHUIIEPR MAY BE INSTALLED VERTICALLY OR HORIZONTALLY, IN ACCORDANCE TO THE DETAILED SPECIF7CA77ONS HEREIN. PANELS MAY BE NOTCHED OR MITERED TO ACCOMMODATE AN OBSTRUCTION ANCHORAGE OF THE SHUTTER SYSTEM TO CONCRE 1 t OR MASONRY SHALL CONSIST OF THE FOLLOWING OR EQUAL WITH MINIMUM ULTIMATE LOAD VALUES SHOWN 1/4" DIA. RAWL LOK /BOLT ANCHOR ( SLEEVED DRIVE ANCHOR ) MIN. TENSILE 1190 — MIN. SHEAR 1520 — 1 1/8" MIN. EMBED. IN CONCRETE MIN. TENSILE 1200 — MI//. SHEAR 1270 — 1 1/8" MIN. EMBED. IN MASONRY 1/4 -20 RAWL CALK —IN ANCHOR ( MACHINE SCREW ANCHOR) WITH 1/4 -20 BOLTS MIN. TENSILE 1870 — MIN. SHEAR 1730 — 7/8" MIN. EMBED. IN CONCRt I L MIN. TENSILE 880 — MIN. SHEAR 134D — 7/8" MIN. EMBED. IN MASONRY 7/4" PER MA —SEAL TAPPER BY RAWL ( MASONRY SCREWS VARIOUS HEAD TYPES ) MIN. TENSILE 1520 — MIN. SHEAR 1980 — 1 1/2" MEN. EMBED. IN CONCRETE MIN. TENSILE 880 — MIN. SHEAR 1270 — 1 1/4" MIN. EMBED. IN MASONRY 1/4" ZAMAC NAILIN BY RAWL (ZAIMAC HAMMER DRIVES ) MIN. TENSILE 960 — A/N. SHEAR 1400 — 1 3/8" MIN. EMBED. IN CONCRRtIt MIN. TENSILE 730 — MIN. SHEAR 7320 — 1 1/4" MIN. EMBED. IN MASONRY ANCHORAGE TO WOOD CONSTRUCTION SHALL BE 1/4" STEEL LAGS OR LARGER WITH 1" MIN. THREAD PENETRATION, 1/4 -20 BRASS WOOD BUSHINGS OR 1/4" ELCO PANEL MATES OR MASONRY SCREW WITH 1 7/8" MIN. THREAD PENETRATION. REFER TO SHEETS 5,6 & 7 OF 7 FOR ANCHOR SPACING AND MINIMUM EMBEDMENTS IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE SOUNDNESS OF THE STRUCTURE TO WITHSTAND THE ADDITIONAL LOADS AND INSURE PROPER ANCHORAGE. EACH PANEL SHALL BEAR A PERMANENT LABEL OR STAMP SHOWING METAL TECH, INC. HIALEAH. FL " DADE COUNTY PRODUCT CONTROL APPROVED " WARNING TO OWNER OR TENANT LOCATED IN EACH HEADER OR ONE PANEL OF EACH OPENING. STATING " STORM PANELS WILL NOT OFFER HURRICANE PROTECTION UNLESS ALL REINFORCING STRAPS OR BOLTS ARE PROPERLY INSTALLED, WHEN REOURED " PERMANENT FASTENER COMPONENTS, EMBEDDED ANCHOR BOLTS, THREADED CONES OR METAL SHIELDS, NOT IN USE, MUST BE PROTECTED AGAINST CORROSION, CONTAMINATION AND DAMAGE AT ALL TIME. - mot L ,.25 THICK • KEEY HOLE WA Jrynti - � ROBERT S. MON3OI R, PE EB— GLU602d FR ?S ETY'GINSZtING, INC. 3 /4'DIA. TA5203 PRODUCT REVISED as con+P?Yjg with the Florida Bedding Cods Acceptance No _ IZZ4 o7 Expiration Date By Miami Dac roduct Control Division a REVISIONS BY 03 /20/98 06/12/98 08/14/98 12/15/00 SP 01/17/01 07/15/02 09/09/02 SP SP SP SP SP SP l • r M I A M I•DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) MetalTech, Inc. 7635 West 2 Court Hialeah, Florida 33014 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as Zone of the Flori ui ding Code. MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 ercin, and has been designed to comply with the High Velocity Hurricane DESCRIPT • N: 0.031" (min.) Steel Storm Panels Shutter APPROV. L DOCUMENT: Drawing No. 98001, titled " Maximum Impact Storm Panel ", sheets 1 through 7 of 7, prepared i Ramms Engineering, Inc., dated January 10, 1998, last revision dated September 09, 2002, bearing the Miami -Dade - • Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact LABELING: Each panel shall bear a permanent label with the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 01- 0205.01 and consists of this page 1 as well as approval document mentioned above. The submitted documentation was reviewed by Helmy A. Makar, P.E. NOA No 01- 1224.07 E piration Date: 03/22/2006 pproval Date: 10/17/2002 Page 1