Loading...
1266 NE 94 St (8)/2674 11. ADDRESS ,Tff LEGAL lot 19 BAY VIEW RECORD GARBAGE TAX PAID BY YEAR ANNUAL TAX PERIOD USED AMOUNT PAID DATE PAID RECEIPT NUMBER r -1 I 6- 3o J1. -Y? ' ,} " /' ) /2 pt M (. ? O` i/ '" y .2.- /'� ' P' '' F :� rt .i � /2674 11. ADDRESS ,Tff LEGAL lot 19 BAY VIEW RECORD GARBAGE TAX MIAMI PERMIT N? 11727 BUILDING ELECTRICAL PLUMBJNG ROOFING Owner of Building 11 Contractor's License No-% Work to be performed under this Permit I+ 4 4 A Architect Contractor or Builder Legal Lot Description. Address of Building Subdi- vision Value of Project This permit is granted to the contractor or builder named above to construct the building or t herefor in strict compliance with all ordinances pertaining thereto and with the understanding th drawings, statements or specifications that may have been submitted to and approved by the p time if the work is not done in compliance with such ordinances or if the plans are changed wi granted is the understanding that the contractor or builder named above assumes the responsfbf pertaining to the work covered hereby whether shown on the plans or drawings or in the sta done by his agents, servants or employees. 4. Signed • INSPECTOR In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. CONTRACTOR OR BUILDER BY SHORES VILLAGE, FLORIDA - - ----- - - - 4-� AUTHORITY 195 r Amt. of H Permit the equipment or device described in the application rk will be performed in compliance with any plans, pal authorities. This Permit may be revoked at any nation. A further condition upon which this permit is a thorough knowledge of the ordinances and regulations specifications and that he assumes responsibility for work N9 1569 CERTIFICATE OF OCCUPANCY Owner, Agent or Tenant of Building Lot ( Block Street Address Approved use by occupancy L Remarks. MIAMI SHORES VILLAGE, FLORIDA BUILDING DIVISION Miami Shores Village, Fla , �— Subdivision ems This Certificate of Occupancy is issued to the above named _ for building at above named location only upon the express provision that the applicant will abide by and comply with all conditions of Ordinances Nos. 92, 93, 94 and 97, known as the Zoning, Electrical, Plumbing and Building Ordinances of Miami Shores Village pertaining to the erection, construction, alteration or remodeling of, b or structures. ■ BUILDING DIVISION N? 1569 CERTIFICATE OF OCCUPANCY MIAMI SHORES VILLAGE, FLORIDA BUILDING DIVISION Miami Shores Village, Fla., Owner, Agent or Tenant of Building Lot Block Subdivision Street Address Approved use by occupancy Remarks: This Certificate. of Occupancy is issued to the above named for building at above named location only upon the express provision that the applicant will abide by and comply with all conditions of Ordinances Nos. 92, 93, 94 and 97, known s the Zoning, Electrical, Plumbing and Building Ordinances of Miami Shores Village pertaining to the erection, construction, alteration or remodeling of buildings or structures. BUILDING DIVISION OWNER'S NAME H.H. Biz= JOB LOCATION (ST. OR AVE.) 1266 N.E. 94th. ST{2T GENERAL CONTRACTOR 120 u• FIME REPAIRS ALTERATION ADDITION SUBMITTED TO PLANNING BOARD RE- SUBMITTED TO PLANNING BOARD CUPMITTED TO VILLAGE COUNCIL APPROVED REJECTED LOT 19 PRESENT ADDRESS ADDRESS BLOCK 1235 N. ^t. PUILDING PERMIT NO 11 7 2 7 DATE 6 /30/51 PERMIT FEE S ZONE r EQUIREMENTS 25,000 CU. FT. PLAN CUBE28I Q DRAWINGS. SPECIFICATIONS. RESTRICTIONS AND CUBE CHECKED BY: l •l• TYPE STORIES ROOF CONSTRUCTION X NEW CONSTRUCTION CB'") 1 1J.L oak floors - -alas. walls & cell's. DESCRIPTION 11v. rm.. --a; n. Tin --- kit. --- break. rm. - -q bed rms.--2 baths -Maids rm.& bath-- screoned tern. -- screened p D orea- a are REFERRED TO COUNCIL "2 .c c CERTIFICATE OF OCCUPANCY NO,,_ -> ISSUED BY t TO BUILDING PERMIT AND INSPECTION RECORD -MIAMI SHORES VILLAGE CU. FT. REMARKS LICENSE NO. SUBDIVISION BAY VIEW PHONE NO. BUILDER'S BOND NO. DATE EST. COST S DATE INTERIOR CONSTRUCTION REASONS PHONE NO. LICENSE NO. !V 14• /,..0...2 BUILDING INSPECTIONS II SPECTIONS DATE BY RE- INSPECT BY RE- INSPECT BY FOUNDATION (� F c TEMPORARY SERVICE $ $ INTEL ._ e� —`8-s reZ/ -. .0 -/ - , V^ �� » /O —G -f/ SEWER $ FRAMING SOLAR HEATER $ $ GAS S $ AT; BY RE- INSPECT S INSPECTIONS FINAL / -. G f^SZ RE- INSPECT BY RE-INSPECT BY ROUGHING CLEAN -UP ■ . • • r GAS CONTRACTOf7,,l v e) � M . ,jsJ PHONE PERMIT NO. ll /� / � /7 1 DATE )" 7 C FEES 1/ 2 REPAIRS \ NEW BLDG. X ALTERATION 1 ADDITION SPECIAL PERMITS PERMIT NO. DATE FEE TEMPORARY SERVICE $ $ SEPTIC TANK /A/ gII n.- - a /SILi » /O —G -f/ SEWER $ $ SOLAR HEATER $ $ GAS S $ AT; BY RE- INSPECT S INSPECTIONS DATE BY RE- INSPECT BY RE-INSPECT BY ROUGHING i-7-5 ROUGHING . • • r GAS H. W. HEATER CONN SEWER A ANGE CONN. SEPTIC TANK n �I' ii G +l' ` l SOLAR HEATER FIXTURES & FINAL FIXTURES )-l)-Sy NEW BLDG. ALT RATION ADDITION REPAIR SPECIAL PERMITS PERMIT NO. DATE FEE TEMPORARY SERVICE $ H. W. HEATER CONN. $ RANGE CONN. - $ MOTORS $ FIXTURES $ S INSPECTIONS AT; BY RE- INSPECT BY RE- INSPECT BY TEMP. SERVICE D ( / / ri �� ROUGHING F /� • • r H. W. HEATER CONN - A ANGE CONN. FIXTURES & FINAL LUMBING PER & INSPECTION CONTRACTOR E CTRICA PERMIT NO. DATE ERM S & INSPECTION FEE $ / J APPROVAL TO POWER CO. FOR SERVICE DATE j - n /r I ,aM�ll MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- i or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. 4/2/69 , Date 19 Owner's Name and Address Mr, Toomer - 1266 N.E_.._94 ___St. ?Ij .ihQres Street Orkin Exterminating Co.Inc.1960 N.W.27 Ave.Miami Registered Architect and /or Engineer Name and address of licensed contractor Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done State work to be done and purpose of building (by floors) 1266 N.E. 94 St.Miami Shores Nylon Tent and Seal Fumigation- Vikane 18 -24 hours 32# $310.0 and for no other purpose. New Building Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Covering Estimated Total cost of improvements $ Amount of Permit $ Zone cubage required plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor_._ __ - ._ . I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Pennanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub- contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such su. ` ors, on work to be performed under this permit, as are licensed by Miami Shores Village. Remarks _ (Signed) s ir STATE OF FLORIDA, ss. COUNTY OF DADE. J Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No ........ _r_ ?" Date Disapproved Da �n ( Signed) - o ' ` (- Building InspecJr 4 - 3 -C-Q Read, Sworn to and Subscribed before me. Notary Public, State of Florida My Commission Expires PLANNING BOARD DATE Chairman Member Member _____ ------- - - - - -- Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty ' materials and /or workmanship. WINGERTER LABORATORIES, INC. Engineer's Laboratory and Inspection Service 1820 N. E. 144th Street 1st Drawer L, North Miami, Florida 33161 REPORT OF: PILE DRIVING INSPECTION CLIENT e CONTL ACTOR e LOCATION: PILE DRIVING CONTRACTOR: PILE MANUF.: DATE OF INSP s REPORTED TO: Mr. Sheldon Toomer, 1266 NE 94 St., Miami Shores, Fla. 33138 ®_ C.o oee o mmodmeo mmeaeev ® evommo me 000 mm� em m01.20 .1.10 o, m�m�� PILE SUMMARY Size Length Bearing Required ire. lad No. ---L2 —Is 10 22 2 17 10 36 G! 17 15 Total EXTENSIONS 10 10 3 17 SLEEVES 10 3 INSPECTORS JR -DR TIME ON JOB DATE 1 972 9 -28 9 °29 10 -2 ARRIVE 2800PM 9 8 00AM 9830 Mr. Sheldon Toomer Mr. Strickland Add ° rL to M::. Toomer Residence 1266 NE 94 St., M=^G _ S!^_C 5 9 Reed Construction Atlantic Products Co. Inc. Sept. 28, 29, Oct. 2, 1972 LEAVE LUNCH TRAVEL 3:30PM o 1.0 Hr 3:00 d . OHr 1.0 3s30 05 1.0 Total Hours DISTRIBUTION 3— Mr. Sheldon Toomer 1 - William Bradford, Bldg. Insp . Rigs Mobile Crane with moveable leads lane r Name of Type Wt. of Hammer Drop: POWER : ENR FORMULA F TCTAL 2.5 Hrs 6..0 15.0 Hrs. W. G. Hicks, DRIVING RIG e DeLMag e 2,750 Lb s. 6.0 ft. Diesel 2E • S � : Respectfully submitted WINGERTER LABOR TORIES P. 042633 10- 6 -72rg Lab. No. 36472 Page 1 of 4 ORDER NO. 1C290. 1 AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES;'1k1.,L33$I - TS ARE.S.0 I'r V' AS THE CONFIDENTIAL PROPERTY OF CLIENTS, AND AUTHORIZATION FOR PUBLICAYIb OF STA,r.EMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WR TEN APPROVAL. 1 1 1 1 3 1st !REPORT OF: CLIENT PRO T 4/ 77 , WINGERTER LABORATORIES, INC. Engineer's Laboratory and Inspection Service 1820 No E. 144th Street Drawer L, North Miami, Florid . 33161 PILE DRIVING INSPECT:0N Mr. Sheldon Taorner Add 'la to Mr. 1oo::der Residence I2 / O- 42633 10607 rg Lab. No. 361472 r- a g 2 o f L. it AS A MUTUAL PROTECTION YO CLIENTS, 'r AN() OU .Sr_tiV�S, ALL 7,1FPORTS ARE SI C'r.r` Y13D AS THE CONFIDENTIAL PROPERTY OF CLIENTS, AND AUTHORIZATION FOR PU®LICA7'C,wr SYw ; ? ?'.�', CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR Wkn'Ti_N APPkOVAL. Dep th Feet 1 thru 1 9 20 21 thru 2 7 28 29 3 31 32 33 thru 41 a b c d e f g ** x ** 1 s J REPORT CF: v -J _ ..~ +v No. WINGERTER LABGRATORI, INC. Engineer's Laboratory and Inspection Service 1820 N. Ea 144th Street D.ra.wer. L North Miami, Florid 3316 PILE,, DRIVING- INSPECTION Mr, Sheldon Tome' .A..dd o n to Mr. Toomey Reside: : :.c e ** 1 2 1 4 13 a =Sizes 1:L3 S r:...are b.---:Length (feet) c.-Bearing Reg (tons) d =No, of 3:-3Ws Las _nc e =Formula tons (safe load) f= :Depth driven feet) g-.'Date drives^. ..ti O CHD O F i3AM E -t BL S! i S 10 28 2O/6°; 2 10 20 6/6" 16 24- 36 0 10 10 22 22 22+10 2% 1O 1C 3 17 17 1705 17G5 17.5 NB N3 305 NB 30 NB N3 i9 1_ir3 18 w w0 2b 40.5 x,05 3 0 9-28 9028 9 -29 9029 9-29 Top of pile broke up- cut -off eG sleeved 2? cut -off from top 1? 70 If PP 4? k* * Top of pile broke up- cut -off & redriver ;J 7 G.. L. 2L. 17.5 '! 0 5 NB NB 28 ■ 2 0.7., I n. 2= 10x22 5- 10x' 3 ,0x `O EXT. 28 1 26 3 3 rg Lab. NO. .36472 Pagc 3 -- 0 AS A MUTUAL PROTECTION YO CLIENTS, 'i SSE: Nurir,:L Aiv0 OUr2SEL.V4 5.;, -A "?E .PRTS J) Cpl _" -h AS THE CONFIDENTIAL PROPERTY OF CU:i Th, ANb AU'T'HORIZATION FOR PU®LICA - TIC,, - CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR wh'YY!:.N 6Je'r- ,ROVAL> 1st :REPORT OF: CLIENT a PRC PILE Mr. Sheldon Toomer Add °n to Mr. Toomer Residence Depth Feet Pile No. 2 2* 11 8 2* 12 14 la 1 thru 28 29 30 31 32 33 34 35 thru 41 42 43 a b c e f g * Redrives m See page 3 for original drive WINGERTER LABORATORIES, INC. Engineer's Laboratory and Inspection Service 1820 N. E. 144th Street Drawer L, North Miami, F1okida 33161 DRIVING INSPECTION EECORD OF HAMMER BLOWS 24 24 20 20 24 20 20 20 10 10 10 36 36 36 i 17.5 ;7,5 i 5 1 .5 2.0 21 21 28 35 34 33 C -2 10 -2 :0-2 24 24 24 28 28 28 20 20 20 10 10 10 36 22 +10 +10 36 2,0 i0 28 39 34 43 10 -2 10 - - 21 0-2 20 24 24 10 36 28 _y0 1O-2 20 20 20 10 s6 0 -42633 10- 6=72rg Lab. No. 36472 Page 4 cf L. 10290.1 24 24 24 24 24 24 AS A MUTUAL PROTECTION TO CLIENTS, THE PUULIG AND OUNSELVL-'$, A'LL- r?QRTS ARC t1'?P::.% - 1 - ED AS THE CONFIDENTIAL PROPERTY OF CLIENTS, AND AUTHORIZATION FOR PUsLICni -to ='?° CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR Vilki i TI N A6-4WFWUVALe MAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPL8CATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Date...= Owner's Name and Address..A ii'ft/'1". CH /3 —/), 7 /1/WIZ Registered Architect and /or Engineer Name and address of licensed contractor fri -4 4 1,( /.% Location and legal description of lot to be built on: Lot `f Block Subdivision /0 1 , / Street and Number where work is to be done ._ it( __ f1l 1 State work to be done and purpose of building (by floors) New Building Remodeling Addition Repairs To be constructed of e O' g Kind of fpundation Estimated Total cost of improvements $ e <i; "= Amount of Permit $ Zone cubage required .Plan Cubage Distance to next nearest building Size of Building Lot Q 1 0 Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to.1' ." .' /= 9h (Signed) Building Insp LL./1 \ ! _ ! _ 19 Street/.yz 9 9' Q'S" P. .r Ai-0;7/5c' .64-y V/ zal and for no other purpose. No of Stories .. _ .� Roof Covering nx��� The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Remarks (Signed).. STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. 11 Permit No.____ _.d ��ari01 Date 'e Z i Read, Sworn to and Subscribed before me. Disapproved D Notary Public, State of Florida ommission Expires ANNING BOARD DATE Chainnan Member Mernber Member Mernber Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. i3 Lc- Z-2 v L Z s' c OWNER'S NAME )fit.. it Ma. u. 5t4E.1411 u Teo MfQ PRESENT /` 1ZG. 14.,11.. - Sr LICENSE NO. PHONE NO. JOB LOCATION (ST. OR AVE.) 4 N.. V . ¶8 m — ` S-r LOT 14 BLOCK I SUBDIVISION N t A ow. % 5... dutV UNIT V i €t•.) GENERAL CONTRACTOR L aw1s )s wa..vEa... ADDRESS 1142r t.w. 94.. ST. PHONE NO. LICENSE NO. BUILDING PERMIT NO. 1 DATE Q "13''7 2 . PERMIT FEE $ (0 - BUILDER'S BOND NO. .. DATE Ir. ZONE REQUIREMENTS CU. FT. PLAN CUBE CU. FT. EST. COST $ 45 X00 P r � DRAWINGS. SPECIFICATIONS. RESTRICTIONS AND CUBE CHECKED BY: `Y. '5ra.d Fo DATL q -1j-?L NEW CONSTRUCTION TYPE C. 13, STORIES t..ao ROOF CONSTRUCTION / 1 $Oi14 Of t INTERIOR CONSTRUCTION 8 .1 r.....- S.A..— 6..re.t• REPAIRS DESCRIPTION d 'II. L E't l (NT A.AA.t V1411A ALTERATION DESCRIPTION ADDITION SUBMITTED TO PLANNING BOARD APPROVED REJECTED REFERRED TO COUNCIL REASONS RE- SUBMITTED TO PLANNING BOARD SUBMITTEn TO VILLAGF COUNCIL REMARKS CERTIFICATE OF OCCUPANCY NO. ISSUED BY TO BUILDING PERMIT AND INSPECTION RECORD —MIAMI SHORES VILLAGE INSPECTIONS DATE BY INSPECTIONS DATE BY FOUNDATION $ SEPTIC TANK ROOF $ BEAMS & LINTELS I POOL $ SOLAR HEATER FRAMING I H. W. HFATER CONN AIR COND. GAS FINAL I $ CLEAN UP SLAB SEPTIC TANK SLAB FIXTURES & FINAL SPECIALS PERMITS PERMIT NO. DATE FEE TEMPORARY SERVICE RE- INSPECT BY $ SEPTIC TANK $ SEWER $ SOLAR HEATER H. W. HFATER CONN $ GAS $ RANGE CONN. INSPECTIONS DATE BY RE- INSPECT BY RE- INSPECT BY ROUGHING ROUGHING TUB & TOP OUT H. W. HFATER CONN SEWER RANGE CONN. SEPTIC TANK FIXTURES & FINAL SOLAR HEATER - FIXTURES GAS ELECTRICAL PERMITS & INSPECTIONS CONTRACTOR PHONE PERMIT NO. 1 DATE FEE $ NEW BLDG. I ALTFRATION 1 ADDITION REPAIRS SPECIAL PERMITS PERMIT NO. DATE FEE TEMPORARY SERVICE $ H. W. HEATER CONN. $ RANGE CONN. $ MOTORS • $ FIXTURES $ Q INSPECTIONS DATE BY RE - INSPECT BY RE- INSPECT BY TFMP.SERVICE ROUGHING H. W. HFATER CONN RANGE CONN. FIXTURES & FINAL - BUILDING INSPECTIONS CONTRACTOR PERMIT NO. NEW BLDG. PLUMBING PERMITS & INSPECTIONS DATE 1 ALTERATION 1 ADDITION APPROVAL TO POWER CO. FOR SERVICE DATE PHONE FEE $ REPAIRS BY Date Legal Description 1 - 0 7 /9 Q E; 5 FT - oic .(.O'" / Lessee / Tenant //71 ' , '4 - Cc91"( Master Permit # 4421 Owner's Address / 76� Ne 9S 3/ Phone 2- SS/ //7 9/62 -&34 Contracting Co. &141 1 A S /'ie-t /GVG, Address<=7904 4 ZZ S1' ;1 � 77-7 Qualifier SS# - - Phone � 03 5 -0 (o V7 State # Municipal # Competency # 40 Ins.Co. Architect /Engineer Address Bonding Company Address Mortgagor Address Permit Type(circle one,�'._,HUILDLNG ECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION £o9, ,e .) ��� /o'e7� Gc -G2)) Go'7C,e&r o/Y 4PPLOxienl; 26o /'r) . eP 7 Cif A9 Square Ft. 200 � //V _ "-. Estimated Cost(value) 2500. o' WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be e in comp nce with all applicable laws regulating construction and zoning. Furthermore, I a .o>`i , /he ove -na ied contractor to do the work stated. ignatu Date: Notary as tc My Commissi APPROVED: 4 ; . ,PERMIT APPLICATION FOR MIAMI SHORES VILLAGE l Job Address 476 AVE 9y# S/ Tax Folio /1 O ,.45 -0 / O -0 /70 Zoning r and /or Condo President 9 9044: b W a tM lit L. ONME lERIPes e e n( COMMISSION 9 CC 693896 EXPIRES: November 4, 2001 ,;;;A Boded Thru Notary Public Undemelbsre ent * RADON C.C.F. Fire Buildin * S gnature o Date: ''c•� �c�L ractor or Oiner- Builder .11 '_ !- MICHELLE M COLLISTER ;PS - ; COMMISSION NUMBER • �:III�.. CC432134 O MY COMMISSION EXP. O *FL * JAN. *5 1999 ** Other 314 N. "ary as to Cont My Commission Ex * * * NOTARY TOTAL DUE Electrical Mechanical Plumbing Engineering OCT `1' -1995. 09:5? 460 P.04 • raw PVC uuMMtr4C MENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. A.asici STATE OF FLORIDA COUNTY OF DADE THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property. and in with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: /-- (o /V ` / 7 ! 9972 / s/�`a,ecsS 4o? / d. /5 7. 0 1.0 2. Description of improvement: I�rr�Ai� ,�� Lc cif G ONC ,ec !, iv /70 C)S 2/z- 4y -„( IV/ILL/ S 6o�y,� 40 Na 99th S/, • /17 / 4 �. -s`��a � s F� 3. 3. Owner(s) name and address: Interest in property' � Name and address of fee simple titleholder: ' /' " 4. Contractor's name and addr ss: g 0 A N V41 OD " 5. Surety: (Payment bond required by owner from contractor, if any) Name and address: Amount of bond' $ / 6. Lender's name and address: 4// 4 - a difie nt date in specified) Af Notary Public Print Notary's Name My Commission Expires: T A X FOLIO NO. 1L,a2OS -O /0 - Q/ 7 d accordance 1 (mu_ 0 ' •.. B 1y- 9. Expiration date of this Notice of Commencement (the expiration date is 1 ear /1C) MY COMMISSION / CC 693896 4T: EXPIRES: November 4, 2001 Boded Rim Notary Put& Undeme tem 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address' 8. In addition to himself. Owner designates the following person(s) to receive a copy of the Lienor's Notice as pro- vided in Section 713.13(1)(b), Florida Statutes. Name and address from tiiiiTagig EIfQt6ccf'rlikli1RWs fS i2c^ 3V CERTIFY thQf this is a truo copy of tho (� , A 0 19 Signature Of • er Print Owner's Na — Sworn to and subscribed before me this day of 19. — � repared by: `/ /7 -1.te Address /24 (, /VE G S// f/ /2) /4-r7/, ..S4-7 , i day o W Y' 'S my h !id and Of.icial Soal. IsAAVE RUVIN.CLERit, of Circuit and CounfyCou t 4 2 j _, ,. Address: 126 NE Street, Miami Shores 111111/110111/111/1 11 11 / i 111, //It' SST / 111111111111111111111 / 1 House D a •9ram '1 Rebuilt 1 / 11/1/111111111111111 111111 Addition J� MASONRY & CONC. RESTORATION GUN CEMENT APPLICATION Date: SNAPP INDUSTRIES, INC. GUNITE SPECIFICATION AS DESCRIBED ON FACE OF CONTRACT Accepted by: Respectfully submitted, Snapp Industries, Inc. Job site: 1266 NE 94th Street Miami, FI PLEASE SIGN AND RETURN ORIGINAL. GM /nd 2902 N.W. 22ND STREET MIAMI, FLORIDA 33142 -7087 Gene Miller Estimator DADE (305) 635.0687 FAX: (305) 638.2131 PRESSURE GROUTING GENERAL BLDG. REPAIRS EPDXY INJECTION SWIMMING POOLS Remove spalled concrete from all of the areas described on face of contract by air hammer chipping sufficiently to expose the outer reinforcing steel that has caused the spalling. This steel will then be sandblasted clean of all rust and scale and wherever any steel has lost 25°6 or more of its original diameter new steel rebars will he spliced in. Replace all removed masonry with gunite. The gunite will be composed of 3 parts screenings and thoroughly premixed with one part Portland cement and shot into place with a minimum air pressure of 75 p•s•i• If at any time it becomes necessary to employ an engineer, architect, or testing lab, the owner agrees to pay for this services. We are fully licensed and insured over minimums required by law and all of our work will be subject to inspection and acceptance by your engineer. This type of work involves sandblasting, which creates a lot of dust that may seep up into floor cracks. Snapp Industries, Lac. is not responsible for cleaning up said dust. MASONRY & CONC. RESTORATION GUN CEMENT APPLICATION Job site: 1266 NE 94th Street Miami, Fl GM /nd SNAPP INDUSTRIES, INC. PLEASE SIGN AND RETURN ORIGINAL. 2902 N.W. 22ND STREET MIAMI, FLORIDA 33142 -7087 DADE (305) 635-0687 FAX: (305) 638-2131 PRESSURE GROUTING GENERAL BLDG. REPAIRS EPDXY INJECTION SWIMMING POOLS GUNITE SPECIFICATION AS DESCRIBED ON FACE OF CONTRACT Remove spalled concrete from all of the areas described on face of contract by air hammer chipping sufficiently to expose the outer reinforcing steel that has caused the spoiling. This steel will then be sandblasted clean of all rust and scale and wherever any steel has lost 25.° or more of its original diameter new steel rebars will be spliced in. Replace all removed masonry with gunite. The gunite will be composed of 3 parts screenings and thoroughly premixed with one part Portland cement and shot into place with a minimum air pressure of 75 p•s•i• If at any time it becomes necessary to employ an engineer, architect, or testing lab, the owner agrees to pay for this services. We are fully licensed and insured over minimums required by law and all of our work will be subject to inspection and acceptance by your engineer. This type of work involves sandblasting, which creates a Iot of dust that may seep up into floor cracks. Snapp Industries, Lic. is not responsible for cleaning up said dust. Accepted by: Respectfully submitted, Snapp Industries, Inc. Date: Gene Miller Estimator r Address: 126° NE Street, Miami Shores 111/1/ //IILUIIl11IIN1111 /11 i I'l rlil�ii 1llillllllllf ��nuu1ii11n�i��l111 Addition House Diagram Rebuilt • BST n / I / lllllllll/ /11 /1!111 /1 1NI1�t11�1�nal�lltnllrl�l /I1h���I1�11 9 MIAMI SHORES VILLAGE BUILDNG DEPARTMENT 305- 795 -2204 Building Inspection Request Datc8 9 7 C5 Type Insp'n e - UCCupc.+ n Permit No. 2 0 ZCIC5 - 1 e3 Name Address 3500 y fit Z 7 Ems (i 0 v9a 12(36 NE q4 s T CompanyCObuzf' � Gnl� Y . Phone # (3a5)754 - 999 ET 3 Inspection Date CJ 18 0 5 Approved Correction ❑ Re- Insp'n Fee ❑ Rev. 10/02/03) RE- OCCUPANCY APPLICATION Miami Shores Village Building Department Date U1S1S Contact Name E-nm 1 h � � V Q Phone # 3 1 51 1 7 EXI' ■ Buyer Seller Realtor 1 Company Name e{k)tuJeli C Property Address 12.V0 I'J City Miami Shores State Fl Zip 531 Loc ID I hereby certify that I understand that the zoning of the property is for single - family residential use and that it is unlawful for more than one family to reside therein. I also understand that any Certificate of Re- Occupancy that may be issued by Miami Shores Village certifies only that the referenced property is being used for single - family purposes and that such Certificate does not constitute any representation, warranty or certification as to the condition of the dwelling or other structures on the property. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate. Applicant , T,,,, Signature Sign: Print: NOTARY PUBLIC: • ''" '4 4.i Notary Public - Slate of Florida My Commission Expires: Building Officials Approval: 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795 -2204 Fax: (305) 756 -8972 Permit No. e0 Zoos - /83 The foregoing inst ment was acknowledged before me this / 5day of by / 1 t , who is personally known to me or who has produced as identification and who did take an oath. 20 bc, Re -Occ. $60.00 Notary $5.00 CCF $0.60 Total 00. 6 0 z�c- k 244I Miami Shores Village, Fla. OWNER ADDRESS *INSPECTION PERMIT NO. CONTRACTOR TIME READY i Aq TELEPHONE NO. (:)� ✓D INSPECTOR DATE