Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
1257 NE 94 St (4)
- MR. M IRS. WALTQ R 1AR U F S 1257 N.E.g4ST. MIAMI rLA• 15I u 89I -21zo oFF. gp MES1r1 -�_ 10 - -- I ;;;://e - / / / / ///// A , , �° // / /////://2/A/// / 1— 1,..:___--.../ = = - •_‘. \\\\\ :ZX1s'Cttu a` PaT1o \-1'- Io'l :" • /': �� � POSED. 1' W PAT 10 AR A. w/ r =FooTE - 7.09, 1 46tss 1>3LF Ro0vA ADDMT1og O I j : . �� to SCREE u E`trlCLDsuR E W 5ML. c•LlA / / :7," ,:///// Lz ..+ .. 4 1 n-5 3 c 1 1 - - d ' �U "x16' Foo1E2 wi z STELt. RODS PRo _ ?Et \tAc . —N # 5 - SIEFL Dods QE ctNECt1 - _ %JEVV . OLD 5 'Rtsc-ToRES 4 � O.C. EX\ 1 uouSE. lo" X16: 'FOOTER wl 2- STEEL - Fog FcrruRE Roo Y1 0`R 9CSEE,J Et■1C1.o5USE lNFW_SLAS - ro MA'TC`} Ex.s V AT• O t , 1 O F E.`R15S 141 q f__""2141 _1 O 0 0 cl o n - ToT A L- `LS.A S ,o �, 4Gt' • o" L} -©, stv -- t)(cLO (9 Ft' 48%,< 1C()"- 37,4 ` x �' 4''. IS � to; 4 Co 1 - 1`0 1 ' .g/ci . I S 89 I i 84-1. to -- tOI(2: is y2, K.c5c, 2 TILE. i‘64 I-. C 1 4- _4_2o .S 410 ) ?�o .� / 2 7/0 -45 -/z 13.2 • 0 NMI PLAN OF SURVEY .I, E. 9 4" Sr SCALE I 20' 1 JOS :89 -6033 [ LOCATION SKETCH j SCALE .rs 100' I • I' ,1 • rU 37.5' , 95.12 X 3 7 5 I % 1 i 75� 9 3 . ` • � 1- ' 5' 7S i 1 1 711 N i■.1. E , 4T" ST . ! • LEGAL DESCRIPTION:Lot 7,MIAMI SHORES RAY VIEW,according to the Plat thereof as recorded in Plat Book 40,Page 16 of the Puhlic Records of Dade county,Florida.- GENERAL NOTES 1) OWNERSHIP IS SUBJECT TO OPINION OF TITLE. . • 2) EXAMINATION OF THE ABSTRACT OF TITLE WILL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS, IF ANY, AFFECTING THIS PROPERTY. 3) (2.22) DENOTES THOSE ELEVATIONS REFERRED TO N/A DATUM: ' . ON AND /OR ADJACENT TO THE PROPERTY 4) LOCATION AND IDENTIFICATION OF UTILITIES WERE NOT SECURED AS SUCH INFORMATION WAS NOT REQUESTED. 5) THIS PROPERTY IS WITHIN THE LIMITS OF FLOOD ZONE - AE • FOR :Walter H. and Jean -ne 1). Barnes DATE :ADril 04,1989 AFFLICA•LE ZONING. UNDERGROUND. ZONING AND BUILDING SET •ACKS . MUST ME CHECKED BY OWNER. ARCHITECT OR BUILDER BEFORE DESIGN OR CONSTRUCTION BEGINS ON THIS PROPERTY. CERTIFIED TO:Universal American Mortgage romp. and Five Points Title.- • 1 HEREBY CERTIFY: That the attached Plan of Survey of the above described property H true , and correct to the best of my knowledge, Information and belief, as recently surveyed and • platted under my direction, also that there are not shove -ground encroachments other than' those shown. This survey meet the minimum technical standards set forth by the Florida Board of Land Surveyors pursuant to Chapter 472.027 Florida Statu> CONSULTING ENGINEERS • / ter / /fir ' < _ ...„. 147 ALHAMBRA CIRCLE No. 230 LAZARO D. ALONSO CORAL (TABLES, FLORIDA , PROFESSIONAL LAND SURVEYOR Phone: (306) 446 -948$ CERTIFICATE NO. 3690 THIS IS A BOUNDARY SURVEY STATE OF FLORIDA NOT VALID UNLESS SEALED WITH AN EMBOSSED SURVEYOR'S SEAL Lot 0 PLANNING B " SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied. with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Date Owner's Name and Address ' =a. z ' _a No Street Registered Architect and /or Engineer c • ..4" ..4" . 7 +� 3 �'t. st,' � ' Name and address of licensed contractor __= y?-4.- _ ---)� Y ' Location and legal description of lot to be built on: , / Block Subdivision ./ Street and Number where work is to be done State work to be done and purpose of building (by floors) and for no other purpose. New Building V Remodeling Addition Repairs _ No. of Stories To be constructed of L / . Kind of foundation .e _�__C ,Clr_4 Estimated Total cost of improvements $__ ,,,e!_ 4 91__0 0 Amount of Permit '. t 44. - 2c, Zone cubage required r ` __�___ Plan Cubage permit, as are licensed by Miami Shores Village. Remarks (Signed) / 1'7. 5 P ,., r -, RD DATE v 1 Roof C'vering 7 _ Distance to next nearest building , ' F _ r ,_Size of Building Lot 2J Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on t i f the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, o work o be performed under this STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths ar..d take acknowledgments, personally ap- peared to me well known, and who, being by me first my sworn, upon deposes and says that he is the of the above described con uction, that he h s carefull read the going application, and that he did sign the same, and that all facts therein by him stated are e. r I Permit No l _ _ U � / Da ___ .; ,._;1 Read, Sworn to and Subscribed before me. Disapproved ! , Notary Public, State of Florida ( Signed) Buildi g Inspector r My Commission Expires Chairman Member Member Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship.