1220 NE 94 St (11)0
3
Max. I
1 MIn.
L3-1_
Mdx.
F•-2.230
I .L
J
(3) L 2.000" J
FULL R.
0 HEADER
6083 -T5 Alum. ALLOY
STORM PANEL TYPICAL ELEVATION
SEE SHEET 3 OF 7 FOR REINFORCING DETAILS W/ US OR 0.
SECTION A -A
4.820
1/4 0 S 5. STUD
RIVETED TO ANGLE
O SPACINGS SHOWN
ON SECTIONS.
CONCRETE ANCHORS (SEE SCHEDULE)
CONCRETE ANCHORS (SEE SCHEDULE)
1.18d
15.500" (TOTAL WIDTH)
0 PANEL
125'
to
L -2. _-.1
® BASE ANGLE
6063 -T5 Alum. ALLOY
3
I Max. 1
1 Min.
4.820
I
� iw�n. 5
Max.
•
N
N
UBE
ENT
RAP
GENERAL NOTES:
1. STORM PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE DADE COUNTY 1994 EDITION OF THE
SOUTH FLORIDA BUILDING COOS.
WINO VELOCITY CONSIDERED 15 110 m.p.n IMPORTANCE FACTOR IS 1.05.
COASTAL ZONE WIND LOADS DETERMINED FOR EXPOSURE "0 FOR BUILDINGS WITH MEAN ROOF HEIGHT OVER
60' -d ONLY. AND FOR EXPOSURE • C FOR BUILDINGS FOR MEAN ROOF HEIGHT EQUAL OR LESS THAN 60' -0.
NON COASTAL ZONE WINO LOADS DETERMINED FOR EXPOSURE C. AS REQUIRED BY ASCE 7 -88.
STORM PANEL'S ADEQUACY FOR IMPACT AND FATIGUE RESISTANCE HAS BEEN VERIFIED
W ACCORDANCE WTTH SECTIONS 2315 k 2314 RESPECTIVELY OF THE ABOVE MENTIONED CODE.
2. ALL ALUMINUM SHEET METAL PANELS SHALL BE 5052 - 1(32 ALLOY.
3. ALL ALUMINUM EXTRUSIONS SHALT. BE 6063 -16 ALLOY UNLESS OTHERWISE NOTED.
4. ALL SCREWS TO BE STAINLESS STEEL 304 OR 316 SERIES.
5. BOLTS TO BE 2024 -T4 ALUMINUM ALLOY. GALVANIZED OR STAINLESS STEEL,
WITH 36 ks. MINIMUM YIELD POINT.
6. ANCHORS TO WALL SHALL BE AS FOLLOWS: (UNLESS OTHERWISE NOTED)
(A) TO EXISTING POURED CONCRETE:
- 1/4 0 TAPCON ANCHORS. AS MANUFACTURED 8Y LT.W. RAMS ET OR ELCO INDUSTRIES.
- 1/4' 0 x 7/8 STAR TAMPIN ANCHORS OR RAWL C4LX -1N. AS MANUFACTURED BY STAR EXPANSION &
THE RAWL PLUG COMPANY RESPECTIVELY.
NOTES:
Al) MINIMUM EMBEDMENT OF TAPCON ANCHORS INTO CONCRETE SHALL BE 1 3/4.
A2) 7/8" TAMPIN ANCHORS OR RAWL CALK - IN SHALL BE ENTIRELY EMBEDDED INTO THE POURED
CONCRETE. NO EMBEDMENT INTO STUCCO SHALL BE PERMITTED.
1/4 0 -20 SCREWS USED SHALL BE 1 I/2- LONG MINIMUM SHOULD STUCCO EXIST.
A3) IN CASE THAT PRECAST STONE, PRECAST CONCRETE PANELS. OR PAVERS BE FOUND ON THE
EXISTING WALL OR FLOOR. ANCHORS SHALL BE LONG ENOUGH TO REACH THE MIN
STRUCTURE BEHIND SUCH PANELS. ANCHORAGE SHALL BE 1 3 4 M INIMUM FOR ANCHORS
MENTIONED IN A l). & 7 FOR ANCHORS MENTIONED IN A2 .
(B) TO EXISTING CONCRETE BLOCK WALL:
- 1/4 0 TAPCON ANCHORS. AS MANUFACTURED BY I.T.W. RAMSET OR DLO INDUSTRIES.
- 1/4' 0 x 7/8' STAR TAMPIN ANCHORS OR RAW& CALK -N AS MANUFACTURED BY STAR EXPANSION &
THE RAWL PLUG COMPANY RESPECTIVELY.
NOTES:
B.1 MINIMUM EMBEDMENT OF TAPCON ANCHORS. INTO THE CONCRETE BLOCK UN1T SHALL
BE 1 1 /d.
B.2) 7 l8 TAMPIN OR RAWL CALK -IN ANCHORS SHALL BE ENTERILY EMBEDDED INTO THE CONCRETE
BLOCK UNIT. NO EMBEDMENT INTO STUCCO SHAM BE PERI.111ED.
1/4 0 -20 SCREWS USED SHALL BE 1 1/2 LONG MINIMUM SHOULD STUCCO COST, AND 1
MINIMUM FOR WALLS WITH NO STUCCO.
8.3) IN CASE THAT PRECAST STONE OR PRECAST CONCRETE PANELS BE FOUND ON THE EXISTING
WALL. ANCHORS SHALL BE LONG ENOUGH TO REACH THE MAN STRUCTURE BEHIND SUCH
PANELS. ANCHORAGE SHALL 81 1 1/4 MINIMUM FOR ANCHORS MENTIONED IN 8.1).
& 7/8 FOR ANCHORS MENTPNED IN 13.2).
(C) ANCHORS SHALL BE INSTALLED FOLLOWING ALL OF THE RECOMMENDATIO NS AND SPECIFICATIONS
OF THE ANCHOR'S MANUFACTURER.
ANCHORAGE TO W000 FRAME BUILDINGS NOT COVERED ON THIS DRAWING SHALL BE ENGINEERED
ON A JOB BY JOB BASIS.
7. PANELS MAY ALSO BE INSTALLED HORIZONTALLY FOLLOWING INSTALLATION DETAIS SHOWN ON SECTIONS
2. 2A, 3, 6 & 6A (SHEET 2 & 3 OF 7).
8. EACH PANEL SHALL HAVE A LEGIBLE AND READILY VISIBLE MARKING INSTRUCTING OWNER OR TENANT
TO SECURE PANELS WITH APPU CABLE REINFORCEMENT DURING PERIODS OF HURRICANE WARNING.
9. R SHAD. BE THE RESPONSIBIUTY OF THE CONTRACTOR TO VERIFY THE SOUNDNESS OF THE STRUCTURE
WHERE SHUTTER IS TO BE ATTACHED TO INSURE PROPER ANCHORAGE.
10. SHUTTER MANUFACTURER'S LABEL SHALL BE PLACED AT BOTTOM OF EACH PANEL
LABEL SHALL READ AS FOLLOWS:
FLORIDA METAL. INDUSTRIES. INC.
HIALEAH. FLORIDA
DADE COUNTY PRODUCT CONTROL APPROVED.
(0)
i
1L ECO INc
TIU.JT TESTING & ENGINEERING COMPANY
6393 N.W. 361 ( St 50. 217. VPC610 CAPDIh� il. 33166
Plot :(305 -1330 . far : (303)671 -1331
WALTER A TINT Jr.. P. E.
FLORIDA Lic. 44167
STORM PANEL - "STORM GUARD"
FLORIDA METAL INDUSTRIES, INC.
1660 W. 33rd. PLACE
I4ALEAH. FLORIDA 33012
KV.
oat 0
alt
She/i6
APPROVED AS COMPLYING WITH THE
SOUTH FLORIDA BUILDING CODE c16 DAT O. ..
BY "MAW .
PRODUCT ✓NTROL DIVISION
BUILDING CODE COMPLIANCE OFFICE
ACCEPTANCE NO - 45L3 • OZ
DADE COUNTY
SCALE
3/
DATE
96 - 67
DRAWING 14e
SHEET 1 OF 7
.063'
n
L
.374'
.188'
.063"
I III IYYYYYY
� 4
1875"
63'
_I . 1--I__ .0 6
n In
o Y
I
-J �•-.ces•
® STUD PLATE
1
DETAIL 1: STUD W/ WING NUT
b
ri
COMPONENTS
• ATTN. BLDG. OFFICIALS
DO NOT ACCEPT THIS DRAWING'
W/0 FLORIDA METAL INDUSTRIES
RAISED CORPORATE SEAL'
.062
(3) L - 2 Do0
FULL R.
20 HEADER
6063 -T5 Alum. ALLOY
16 GAGE
Typ.
F
05 STEEL T
REINFORCEM
ASTM A -525 W/
FY = 33 ksi
07 ALUMINUM ST
CONCRETE
ANCHORS
(SEE SCHEDULE)
POURED
CONCRETE
OR CONCRETE
BLOCK WALL
REOUIP.ED
POURED
CONCRETE
OR CONCRETE
BLOCK WALL
REQUIRED
(SEE SCHEDULE)
FOR Min.
SEPARATION TO
EXISTING GLASS
OF WINDOW OR
S. G. D.
CONCRETE /
ANCHORS
(SEE SCHEDULE)
POURED CONCRETE
OR CONCRETE
BLOCK WALL
REQUIRED
1 (SEE SCHEDULE)
FOR Min.
I SEPARATION TO
1 EXISTING GLASS
OF WINDOW OR
S. C. D.
SECTION ® ANCHOR
SECTION ® STUD
Cont.
b
n3
Cont.
J
7/3" x 3/32°
WING NUT 0 i f
EVERY STUD
0 170. C. c
I
WALL MOUNTING INSTALLATION
— SECTION 1
NOTE: DETAIL OF SECTION 0 STUO vANJO ALSO FOR
. , WALL MOUNTING INSTALLATION — SECTION 2
CONCRETE
ANCHORS
(SEE SCHEDULE)
POURED
CONCRETE
OR CONCRETE
BLOCK WALL
REQUIRED
POURED I
CONCRETE
OR CONCRETE
BLOCK WALL
REQUIRED
CONCRETE
ANCHORS
(SEE SCHEDULE)
(SEE SCHEDULE)
FOR Mn.
SEPARATION TO
COSTING GLASS
OF WINDOW OR
S. G. 0.
Cont.
A
es
0.
o.
0
3
WALL MOUNTING INSTALLATION
— SECTION 2
E. D. = EDGE DISTANCE
(SEE SCHEDULE
ON SHEET 7 OF 7)
CONCRETE
ANCHORS
(SEE SCHEDULE)
POURED ` " POURED
CONCRETE CONCRETE
OR CONCRETE OR CONCRETE
BLOCK WALL BLOCK WALL
REQUIRED 0 REQUIRED
POURED
CONCRETE
OR CONCRETE
BLOCK WALL
REQUIRED
CONCRETE
ANCHORS
(SEE SCHEDULE)
POURED CONCRETE
OR CONCRETE
BLOCK WALL
REQUIRED
1 - •-(SEE SCHEDULE
I TO
FOR Min. SEPARATION
113F OOSTING
1OF WINDOW OR S.G.D
SECTION ® ANCHOR
1 (SEE SCHEDULE)
FOR Min
I SEPARATION TO
1 DUSTING GLASS
OF WINDOW OR
I S. C. D.
9
1/4' 0 -20
THRU BOLT W
7/8 x 3/3
WING NUT 0
12' 0. C.
SECTION @ STUD
7/Er x 3/32' i
WING NUT • a
EVERY STUD
0 6' O. C. 0
1
Cont.
Cont.
Cont.
WALL MOUNTING INSTALLATION
— SECTION 2A
CONCRETE
ANCHORS
(SEE SCHEDULE)
POURED /
CONCRETE
OR CONCRETE
BLOCK WALL
REQUIRED
CONCRETE
ANCHORS
(SEE SCHEDULE)
(SEE SCHEDULE)
FOR Min.
SEPARATION TO
DOSTINC GLASS
OF WINDOW OR
S. G. D.
WALL MOUNTING INSTALLATION CEILING & FLOOR MOUNT. INSTALL.
— SECTION 3
Cont.
Cont.
/ IL ECO1 NC .\
TILUT TESTING Nt ENGINEERING COMPANY
6595 NA.. 36U7. Sl. St. 217. V117CIIM CARDERS. R. 33166
Mono : (305)671 -1330 . ro : (303)871 -1331
WALTER A. T1LLR Jr.. P. E.
FLORIDA Lk. 44167
1/4' 0 -20 x
1 BOLTS
W/78' x
3/3 WING
NUT 0
12' 0. C.
1/4' 0 -20 x
W/ 7/Er x
3/37 WINO
NUT 0
17 0. C.
IV. x9
7
0
W
v
POURED CONCRETE
REQUIRED
POURED CONCRETE
REQUIRED
— SECTION 4
STORM PANEL — "STORM GUARD"
FLORIDA METAL INDUSTRIES, INC.
1660 W. 33rd. PLACE
HIALEAH. FLORIDA 33012
°CSCSnot
COSERAL
CONCRETE ANCHORS
(SEE SCHEDULE)
9877
9/16/96
RV. U.
3
•
0
C. D.
CONCRETE
ANCHORS
(SEE SCHEDULE
D.
ConL
7/8' x 3/32'
WRAC NUT 0
EVERY STUD
0 12' 0. C.
7/8' x 3/32'
SEE WING NUT O
I FOR Min. SEPARATKNN EVERY i O. C.
1 TO EXISTING GLASS OF
WINDOW OR S. G. D. p x
APPROVED AS COMPLYING WITH THE
SOUTH FLORIDA BUILDING CODE
DAT • / __ R `7
BY
PRODUCT CO ROL DIV!S:ON
BUILDING CODE COMPLIANCE OFFICE
ACCEPTANCE NO CM D.SI
DADE COUNTY
SCALE
3/13/96
DATE
96 — 67
DRAWING No
SHEET 2 OF • 7
•
CONCRETE ANCHORS
(SEE SCHEDULE)
POURED
CONCRETE
OR CONCRETE
BLOCK WALL
REQUIRED
0
POURED
I-- (SEE SCHEDULE)
FOR Min. SEPARATION
TO EXISTING GLASS OF
WINDOW OR S. G. D.
CONCRETE
OR CONCRETE
BLOCK WALL
REQUIRED
CONCRETE ANCHORS J
(SEE SCHEDULE)
r x r oR r x 4- OR
7 x 5 ■ .125 Alum.
ANGLE (6063 -T6 AL LOY)
1/4 0 -20 5. S. MACHINE
BOLT W/ NUT & WASHER
O 6" O. C.
N
1/4" a -20 1
RV BOLT 7 / w
7/8' x 3/37
WING NUT 0
17 0. C. ta
7 /5 x 3/37
WING NUT 0
EVERY STUD
0 17 0. C.
1' Min. -+1
1/4 0 -20 S. 5. MACHINE
BOLT W/ NUT & WASHER
O 6' 0. C.
✓ x r OR r x 4 OR
✓ x 5 x .125 Alum.
ANGLE (6063 -16 ALLOY)
WALL MOUNT. INSTALL. (OFFSET)
— SECTION 5
118 POP JACXNUT
(Typ.)
1/4 -20x4'
BOLTS W/ WING NUT
do WASHER 0 LAP
JOINTS & ENDS.
Cont.
1/4. 0 -20 x 3/4'
BOLTS W/ WING NUT &
MASHER O LAP JOINTS.
RAWL CALK -IN OR
TAMPIN ANCHORS - \
ol
POURED
CONCRETE
OR CONCRETE — —
BLOCK WALL i
REQURED A
0
(SEE SCHEDULE)
FOR Min.
I Mi SEPARATION TO
1 EXISTING GLASS
OF WINDOW OR
1 S. C. 0.
POURED
CONCRETE
OR CONCRETE E —
BLOCK WALL
REQUIRED
RAWL CALK -IN OR
TAMP IN ANCHORS
o 17 0. C.
WALL MOUNTING INSTALLATION
(DIRECT MOUNT) — SECTION 6
12.0007
PANEL REINFORCING DETAIL W/ 0
PANEL REINFORCING DETAIL NA/ g
/ IL ECO INC. \
TILUT TESTING at ENGINEERING COMPANY
6503 M.W 36N. SL. Stem 217. **33cm• 61R13E16, R. 33164
inw : (305)071 -1330 . Im : (303)671 -1331
WALTER A. TILLR Jr.. P. E.
FLORIDA Lie. 44167
STORM PANEL — "STORM GUARD"
FLORIDA METAL INDUSTRIES, INC.
1660 W. 33rd. PLACE
HIALEAH, FLORIDA 3.3012
xcv.
00
OCXmflco1
LtveRAL
.an
=ilt EAL
xxv, x•
•
•
xtsr�l+oi
an
AS SHOWN
3/13/96
DATE
96 — 67
DRAWING No
SHEET 3 Of. 7
12.000r
0.
RAWL CALK -IN OR
TAW PIN ANCHORS
0 17 0. C.
POURED
CONCRETE
OR CONCRETE
BLOCK WALL }
REOUIRED A I
0
POURED
CONCRETE
OR CONCRETE C
BLOCK WALL
REQUIRED
RAWL CALK -IN OR
TAM PIN ANCHORS
0 170. c.
WALL MOUNTING INSTALLATION
(DIRECT MOUNT) — SECTION 6A
O MIDSPAN
FOR M'm.
SEPARATION TO
EXISTING GLASS
OF WINDOW OR
S. G. D.
O 24' 0. C.
t/4 0 -20
THRU BOLT W/
7/5 x 3/37
WING NUT 0
17 0. C.
7/8 x 3/37 WING NUT
0 EERY STUD OR
M. B. 0 17 0. C.
EXISTING / I
GLASS
POURED CONCRETE /
OR C. B. S. REOUIRED
'(SEE SCHE )
[(SEE
Min.
I SEPARATION TO
EESTNG GLASS
I OF WINDOW OR
S. G. 0.
E. D. = EDGE DISTANCE
(SEE SCHEDULE
ON SHEET 7 OF 7)
Cont.
c 3
INSTALLED AT PASS THRU WINDOWS
W/ 77 Mcx.
SPAN
NEWT" x 4' OR 7 x 4' P. T.
W000 BLOCK BETWEEN
COUNTER TOP STIFFENERS.
1/4' • THRU BOLT W/ NUT
& WASHER 0 6 0. C.
EXISTING COUNTER TOP
W/ Mox. 1/8' TILE
FINISH MATERIAL do
3/4 PLYWOOD.
7 x 5 x .125 Alum. ANGLE
BETWEEN COUNTER TOP STIFFENERS
(Min. 6' LONG) OR Cont.
IF NO COUNTER TOP STIFFENERS
CONCRETE ANCHOR 0 6 0. C..
BOTTOM CONNECTION DETAIL FOR STORM PANELS
: VAUO FOR MAXIMUM SHTTER
HEIGHT - 6 R. AND MAXIMUM
DESIGN PRESSURE a 70 psf.
APPROVED AS COMPLYING WITH THE
SOUTH FLORIDA BUILDING CODE
DAT I , . •• E 19
BY ,1 �.. ;VISION PRODUCT Cr TROL
BUILDING CODE COMPLIANCE OFFICE
ACCEPTANCE NO.96 —6513. 6z
DADE COUNTY
MAXIMUM
DESIGN
LOAD
" W (p.s.f.)
TOTAL MOUNTING HEIGHT "H
.< 1O• -0"
10'< H <12'
12'< H <14'
14'< H <16'
40
7' —T
T -2'
6' -10'
6' -6'
10' -8
10•-1'
9' -7"
9' -2'
50
7' - 1"
6' -8"
6' -4'
6•-0"
9 * -11"
9' -4"
8' -11"
8' -6'
60
6' -8"
6' -3"
5' -1 t"
5•-8'
9' - 4"
8•
8•
8' - 0"
70
6' -4"
5' -11"
5' -8"
5' - 5
8•
8' - 4"
7' - 11'
7' - r
80
6' - 0"
5' - 8"
5•
5• -2"
8' -6'
8' -0-
7• —r
7• -3"
90
5' -1Cl
5' -6"
5' -2"
5' -0'
8' -2'
7' -8"
7• -4
7*-0
• CONCRETE ANCHORS
(SEE SCHELWtE)
POURED CONCRETE
OR CONCRETE
BLOCK WALL
REQUIRED
POURED CONCRETE
OR CONCRETE
BLOCK WALL
REQUIRED
(SEE SCHEDULE)
FOR ►Fin.
SEPARATION TO
EXISTING GLASS
OF WINDOW OR
5. G. D.
Cont.
b =
1n 0
Nm
E. 0.
7/5 x 3/32"
WING NUr co
EVERY STUD
Cont.
2" x4OR
r x r x .125
HORIZONTAL Alum.
TUBE MULLION
(6063 -76 ALLOY)
7/5 x 3/32'
WING NUT 0
EVERY STUD
//1/ 1////
_ CONCRETE %
ANCHORS
(SEE SCHEDULE).
E. D.
Nj
Cont.
(0
g
_
NOTE : FLOOR & CEILING MOUNT INSTALLATIONS SHOWN.
FOR DIFFERENT MOUNTING INSTALLATIONS SEE
TYPICAL SECTIONS ON SHEET 2 & 3 OF 7.
0
SPLIT PANEL MOUNTING INSTALLATION
— SECTION 7
HORIZONTAL TUBE MULLION
CONNECTION TO WALL
FOR SPLIT PANEL INSTALLATION
E. D. - EDGE DISTANCE
(SEE SCHEDULE
ON SHEET 7 OF 7)
EDGE OF EXISTING
WALL
(2) 3/8- • THRU
B OLTS w/ WASHER
& NUT
✓ x4 "OR1 x6" x
125" HORIZONTAL TUBE MULLION
(606.3-76 ALLOY)
• x r x 1/4- x 0' -(F
Alum. ANGLE (6063 -T6 AU
Typ. TOP & BOTTOM)
3/Er • KWIK BOLT ANCHOR W/
2 1/1 Mn. PENETRATION INTO
CONCRETE OR GROUT FILLED BLOCK
MAXIMUM MULLION SPAN (HORIZONTALLY) SCHEDULE
2 - x4" TUBE
2 "x6' TUBE
MULLION TUBE
O END CUT PANEL
2"x4 "x 125
3105 -H14 OR 606.3-T6 ALLOY
Cont. Alum. ANGLE
MEASURED TO CENTER LINE OF ANGLES
TYPICAL SPLIT PANEL
INSTALLATION ELEVATION
W/ MULLION TUBE
rj11
CASE A (Plan)
/
/
/
/7//7/////7//// /77
1 7777777777/7777`%77T7
MUUJON WWI
2" x r x .055 TO
r x 5' x .055 Cont.
Alum. ANGLE OR
.080' 3105 -H154 SHEET
METAL Alum. BENT PLATE
POURED CONCRETE
CONCRETE BLOCK WALL
REQUIRED
CONCRETE ANCHORS
@ 11 0. C.
POURED CONCRETE
OR
CONCRETE BLOCK WALL
REQUIRED
2.500 Min.
CONCRETE ANCHORS 2. 1
0 12 O. C.
POURED CONCRETE
OR
CONCRETE BLOCK WALL
REQUIRED
1.000
ALTERNATE LEG LOCATION
CASE C (Plan)
END CLOSURES DETAILS
1/4 • BOLT
0 11 0. C.
W /JACKNUT
CASE B (Plan)
O OR
O OR ®
x 4 x .093°
3103 -H14 OR 6063 -16 ALLAY
Cont. Alum. ANGLE OR
18 CAGE Goly. STEEL ANGLE
APPROVED AS COMPLYING WITH THE
SOUTH FLORIDA BUILDING CODE
DAT L. . : CI6
BY
PRODUCT CN TROL DIVISION
BUILDING CODE COMPLIANCE OFFICE
ACCEPTANCE NO. b -N 5I. •OZ
DADE COUNTY
/ IL ECO I N C .
TIWT TESTING & ENGINEERING COMPANY
6343 M.M. 3644. S_ Su. 217 VRCAM' GARDENS. R 33186
Pl,ar : (305)871 -1530 . fa. : (306)871 -1531
WALTER A. TILUT Jr.. P. E.
FLORIDA Lk. 44167
STORM PANEL — "STORM GUARD"
FLORIDA METAL INDUSTRIES. INC.
1660 W. 33x4. PLACE
HIALEAH. FLORIDA 33012
rt
•
ICC 03
-,C.N RPL
bar
Gfi&J4L
do
3/13/96
DATE
96 — 67
DRAWING No
SHEET 4 Of ,7
r �etil
I WOOD HEADER
REQUIRED
- (SEE SCHEDULE)
FOR Min. SEPARATION
TO EXISTING CLASS OF
WINDOW OR S. G. D.
1/4' 0 x 1 1/2' LAC
SCREWS 0 6' 0. C.
ALTERNATIVE 1
*
! I�Wi •
0
Q
#14 x 3/4' S. 5.
S. M. S. 0 6" 0. C.
ALTERNATIVE 2
1/4" 0 x r LONG
LAG SCREWS 0 6' 0. C.
w 1 1 / r Min. PENETRATION
TO DUSTING 01000 HEADER.
r xrOR2' x 4 OR 2' x5
x .125 Alum. ANGLE (6063 -16 ALLOT)
1/4" • MACHINE BOLT W/
NUT Cr WASHER O 6' 0. C.
1. r7,1 `II u+.
Cont.
Cont.
WALL MOUNT. INSTALLAT. (OFFSET)
- SECTION B
ti
0
z
W
Id
k
7/8' • x 3/32'
WING NUT 0 EVERY
STUDO 12' 0.0
Cont.
1.250. Min.
1/4' 0 -20 S. S. BOLTS 0
6 0. C. W/ NUT & WASHER
2' x3" OR 2' x4' OR 2' x5 x.125
Num. ANGLE (6063 -76 ALLOY)
NEW P. T. 7 x 6" Cont. W /(2) 1/4' • x 5'
LAG SCREWS 0 EACH STUD (MIDWIDTH
OF STUD. 2" Min. NOMINAL) AND W/ 2'
Min. PENETRATION INTO COSTING STUD.
7/8' • x 3/32'
WING NUT 0 EVERY
STUD 0 12' 0. C
1.0001 Min.
1/4' 0 -20 S. S. BOLTS 0
r O. C. W /NUT & WASHER
2 ' x r x OR r x 4 OR 2' x 5' x .125"
Num. ANGLE (6083 -T6 ALLOY)
1" x 4' x .125' (Min.)
Num. TUBE (6063 -15 ALLOY)
(2) 1/4' 0 x 4° LAC SCREWS 0 EACH
STUD (MIDWIDTH OF STUD) AND w/ 2"
Min. PENETRATION INTO EXISTING STUD.
NOTES:
1. INSTALLATIONS ARE ONLY VAUD FOR DESIGN WIND LOADS AND PANEL'S
SPANS AS PER SCHEDULE SHOWN ON SHEET 7 OF 7.
2. NEW 2' x 6 P. T. TO BE SOUTHERN PINE No. 2. SURFACED DRY WITH
19 X M. M. C. W/ SPECIFIC DENSITY OF 0.55.
3. FOR NEW WOOD FRAME CONSTRUCTION: W000 MEMBERS TO BE SOUTHERN
PINE No. 2, W/ SPECIFIC DENSITY OF 0.55 OR EQUAL.
W
W000 HEADER
REQUIRED
WALL MOUNT. INSTALLATION
- SECTION D
NOTE:
PANEL Q CAN ALTERNATIVELY
E ATTACHED' TO WALL W/
4 TRACK BUT USING 1/
-20 x 2 1/2' S. S.
SCREW 060. C. w/
3 /8' • x 5/8' LONG
BRASS BUSHING.
WOOD TRUSSES OR RAFTER
0 24" 0. C. REQUIRED
ALTERNATIVE 1
3 /6' x 5/8' LONG
BRASS BUSHING w/
1/4' 0 -20 x 2' S. S.
SCREW 0 6' 0. C.
O MOWIDTH OF PLATE
3/8' x 5/8' LONG BRASS
BUSHING W/ 1 /4' 0 -20 x
2' S. S. SCREW 0 C.
TO EXISTING WOOD PLATE.
NEW 2' x 4" OR 2" x x.125'
Cont. Alum. ANGLE W /(2) 5/16 0
x 3' LAG SCREWS TO EACH
RAFTER OR TRUSS. LOCATE SCREW
AT MIDWIDTH OF EXISTING W000
MEMSER (2' M.V. NOMINAL 0110TH)
w /2" 1,6n. PENETRATION.
WALL MOUNT. INSTALLATION
- SECTION E
NOTE FOR COMBINATION OF SECTIONS:
FLOOR/ WALL/ CEILING MOUNTING SECTIONS CAN BE
COMBINED IN ANY WAY TO SUR ANY INSTALLATION.
W000 TRUSSES OR RAFTER
0 24' 0. C. REQUIRED
1/4' 6 x 1 1/2'
LAC SCREWS
0 6 0. C.
(SEE SCHEDULE)
FOR Min. SEPARATION
TO EXISTING GLASS OF
WINDOW OR S. G. D.
7/8" 0 x 3/32'
WING NUT 0 EVERY
STUD 0 12' 0. C -�
• NOTE: FOR INSTALLATIONS THAT NEED NOT TD BE REMOVABLE.
USE 1/4' 0 x 1 1/2' LAG SCREWS 0 6" 0. C.
1/4" . x r LONG LAG
2
SCREWS 0 6 0. C. W/
1 1/2' Min. PENETRATION
TO EXISTING WOOD HEADER
Cont.
1/4' 0 -20 x 1°
BOLTS W/ 7/6 x 3/37
WING NUT O
12" 0. C.
Cont.
O MIDWIDTH OF PLATE
1/4' 0 x 3' LONG LAG
SCREWS 0 60. C. W/
1 1 7 Min. PENETRATION
TO DCISITNG WOOD PLATE.
0
z
W
NEW 2' x 6' P. T. Cont.
W000 PLATE W/
(2) 5/16 • x 6
LAG SCREWS 10 EACH
RAFTER OR TRUSS.
LOCATE SCREW AT MIDWIDTH
OF EXISTING WOOD MEMBER
(2' MAN. NOMINAL 1
W/ 2' Min. PENETRATION.
ConL
2" x 6 WOOD DECK
REQUIRED
(NO FINISH ALLOWED)
3/8' x5/8'
LONG BRASS BUSHING
w/ 1/4' 0 x 1 1/2' 5. S.
S. IA. S.060.C. •
IL ECO.
TILLTT TESTING & ENGINEERING COMPANY
6505 R,w. 38th. 5t.. 75 217 11140 MA WOOFS. 1. 33106
WALTER A. TILLR Jr.. P. E.
FLORIDA Lk. 44157
10
6000 TRUSSES OR RAFTER
• 24" 0. C. REQUIRED
.500
14 x 3/4"
.S.S.M.S.
06 0. C.
( SEE SCHEDULE)
FOR Min. SEPARATION
EXSING GLASS
WINDOW OR S. C. 0.
815Z NM:ft
OEMOUL
SOT
9/18/96
a
r Min.
ALTERNATIVE 3
INSTALLATION DETAILS ON
EXISTING WOOD BUILDINGS
APPROVED AS COMPLYING WITH THE
SOUTH FLORIDA BUILDING CODE
DAT L D . - _ - 7 9
BY 11FER✓ ✓ . .
PRODUCT CON 'OL DIVISION
BUILDING .CODE COMPLIANCE OFFICE
ACCEPTANCE NO. 96' O5I3. Z
STORM PANEL - "STORM GUARD"
FLORIDA METAL INDUSTRIES; INC.
1660 W. 33rd. PLACE
HIALEAH. FLORIDA 33012
1' x 4' x 1/8' Min.
(6063-T5) Num. TUBE W/
L o x 4' LAG
" SCREWS TO EACH JOIST. 5/1
LOCATE SCREW AT
MIDWIDTH OF EXISTING
W000 MEMBER (2' Min.
NOMINAL WIDTH) w/
2' Min. PENETRATION.
Cont.
7/8' 0 x 3/32'
WING NUT 0 EVERY
STUD 0 12' 0. C
xv= 2' x 6" W000 DECK
REQUIRED
(NO FINISH ALLOWED)
3/8" 0 x V8
LONG BRASS BUSHING
w/ 1/4' • x 1 1/2'
S.LI.S.
• NOTE: FOR INSTALLATIONS THAT NEED NOT TO BE REMOVABLE,
USE 1/4' • x 1 1/2' LAC SCREWS • 6 0. C.
CEILING & REMOVABLE FLOOR MOUNTING INSTALLATION
- SECTION C
3/13/96
DATE
•
DADE COUNTY
96 - 67
DRAWING No
SHEET 6 OF 7
MAXIMUM DESIGN LOAD
W (p.s.f.)
,
Max. PANEL SPAN
L (ft.)
MAXIMUM ANCHORS SPACING ••
APPLICABLE TO
SECTIONS
(SEE SHEET 2 & 3 OF 7)
+58.0.
TAPCONS
TAMPINS / RAW CAL -IN
APPUCABLE TO
SECTIONS #
TO CONCRETE
TO MASONRY
TO CONCRETE
TO MASONRY
-72.0
+58.0. -76.0
6"
0. C.
6" 0. C.
6" 0. C.
6' 0. C.
1
+72.0, - 72.0
6"
0. C.
6" 0. C.
6' 0. C.
6" 0. C.
2
+57.2. -75.7
6"
0. C.
6" 0. C.
6" 0. C.
6" 0. C.
2A
+52.0, -56.0
6"
0. C.
6" 0. C.
6" 0. C.
6' 0. C.
3
+50.0, -72.0
12"
0. C.
-
1 Y 0. C.
-
4
+72.0. - 72.0
6"
0. C.
6" 0. C.
6" 0. C.
6" 0. C.
5
+58.0, -76.0
8' -3"
-
-
12" •••
12" •••
6
+72.0. -72.0
-
-
12' •••
12" •••
6A
MAXIMUM DESIGN LOAD
W (p.s.f.)
Max. PANEL SPAN
L (ft.)
MINIMUM SEPARATION
TO GLASS
APPLICABLE TO
SECTIONS
(SEE SHEET 2 & 3 OF 7)
+58.0.
-76.0
1/2"
8' -10 1/4"
2
11/16"
1
+72.0,
-72.0
-
8' -9'
2
1/2"
2
+57.2,
-75.7
12' -0'
2
3/4"
2A
+52.0.
-56.0
•
8' -10 1/8'
2
7/8"
3
+50.0,
-72.0
7' -7 1/7
2"
4
+72.0.
-72.0
8' -6'
2
1/2'
5
+58.0,
. -76.0
5' -10"
2
7/8'
6
+72.0,
-72.0
8' -3"
2
1/2"
6A
ACTUAL E. D.
FACTOR
3"
.86
2
1/2"
.71
2"
.50
MAXIMUM DESIGN PRESSURE RATING "W" (p.s.f.) AND
CORRESPONDING MAXIMUM SPAN "L" SCHEDULE
MAXIMUM DESIGN PRESSURE RATING "W' (p.s.f.) AND CORRESPONDING MAXIMUM ANCHOR
SPACING SCHEDULE FOR INSTALLATIONS INTO CONCRETE AND C.B.S. STRUCTURES *
* SEE ShEETS 5 & 6 OF 7 FOR ANCHORS
TYPE & SPACING FOR INSTALLATIONS
INTO WOOD FRAME BUILDINGS.
E. D. = EDGE DISTANCE
( ) )7 A=2--
* *
MAXIMUM ANCHOR SPACINGS ARE VALID * #
FOR 3 1/2" EDGE DISTANCE.
FOR E. D. LESS THAN 3 1/7, REDUCE ANCHOR
SPACING BY MULTIPLYING SPACINGS SHOWN
ON SCHEDULE BY THE FOLLOWING FACTORS.
IL ECOINc.\
TILLTT TESTING t ENGINEERING COMPANY
4:02 M.W. 3tltn. A-. Std 217 C M CA WS. R 33156
Prior : (305)071 -1330 . F.. (303)071 -153
WALTER A. TILLR Jr.. P. E
FLORIDA Lic. 44167
eosIPetol
DIRECT MOUNT CONNECTION TO WALL W/
ANCHORS AT 12' 0. C., AND 8' -
Max. PANEL SPANS SHALL ALWAYS BE
PERFORMED W/ 3 1/2" EDGE DISTANCE (E. D.).
USE MAXIMUM ANCHORS SPACING OF 6" 0. C.
FOR DIRECT MOUNT INSTALLATION WHERE
E. D. IS LESS THAN 3 1/2" WITH A MINIMUM
OF 2 1/2".
001
✓rt -'7�i�
NM. Be
s
APPROVED AS COMPLYING WITH THE
SOUTH FLORIDA BUILDING CODE
OV
19q
DAT
BY
PRODUCT COI ' 01 DIVISION
BUILDING CODE COMPLIANCE OFFICE
ACCEPTANCE NO.g6
STORM PANEL - "STORM GUARD"
FLORIDA METAL INDUSTRIES, INC.
1660 W. 33rd. PLACE
HIALEAH. FLORIDA 33012
can
DADE COUNTY
SCALE
3/13/96
DATE
96 - 67
DRAWING No
SHEET 7 OF 7
PRODUCT CONTROL NOTICE OF ACCEPTANCE
GAF Materials Corporation
1361 Alps Road
Wayne, Ni 07470
Your application for Product Approval of:
GAFRuberoid® Modlfed Bitumen Roof Systems for Wood Decks
under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of
Construction, and completely described in the plans, specifications and calculations as submitted by:
Dynated, Engineering, Inc, Factory Mutual Research Corporation, and Underwriters Laboratories, Inc
has been recommended for acceptance by the Building Code Compliance Officszo be used in Dade County, Florida
under the specific conditions set forth on pages 2 -60 and the standard conditions on page 61.
This approval shall not be valid after the expiration date stated below. The Building Code Compliance Office
reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality
control testing. If this product or material fails to perform in the approved manner, the Building Code Compliance
Office may revoke, modify, or suspend the use of such product or material immediately. The Building Code
Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance
Office that this product or material fails to meet the requirements of the Building Code Compliance Office that this
product or material fails to meet the requirements of the South Florida Building Code.
The expense of such testing will be incurred by the manufacturer.
Acceptance No.: 97- 0804.14
Expires: 11/06/00
This application for Product Approval
Compliance Office and approved by the
conditions set forth above.
Approved: 11/06/97
•
Revises No.: 95- 1003.03
/
Raul Rodriguez
Product Control Supervisor
THIS IS THE COVERSHEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL
CONDITIONS
• BUILDING CODE COMMITTEE
has been reviewed by the Metropolitan Dade County Building Code
Building Code Committee to be used 'n Dade County, rid under the
. t // r Pi •
Charles Danger, P.E.
Director
Building Code Compliance Dept.
Metropolitan Dade County
A Iicant:
GAF Materials Corporation
1361 Alps Road
Wayne, NJ 07470
Cate or
Sub - Category•
Sub
"T ye:
. PRODUCT CONTROL NOTICE OF ACCEPTANCE •
ROOFING SYSTEM APPROVAL
•
Membrane Roofing System
Built -up Roofing
Modified Bitumen
APP and SBS
Product Control No: 97- 0804.14
Product Control No.: 97- 0804.14
Approval Date: November 6, 1997
Expiration Date: November 6, 2000
System Description
GAF Materials Corporation has been manufacturing commercial roofing g products for more than 100
GAF produces a wide range of roof products for built -up roofing systems. The modified bitumen
products include both APP and SBS products in smooth, granule and fire rated versions. In addition
GAF offers two ply modified systems to meet the specification requirements for multilayer d'
specifications. Y er SBS modified
GAF products are distributed through a wide network of roofing wholesale distributors throughout
South Florida area. g t the
GAF provides warranted systems over various insulated and non - insulated substrates, copies of which
can be obtained from GAF and can be found in the Ruberoid Modified Bitumen Application and c)t
Specification manual published annually.
GAF roof system assemblies have been extensively tested at Factory Mutual Research Co
Underwriters Laboratories. GAF modified bitumen membranes have been tested in compliance n h nd
ASTM D 5147 test requirements. p ance with
Contact:
William J. Woodring
Director of Technical Services
(973) 628- 4134
•
Frank Zuloaga,
Roolinn Preri,tnt •
Insulation Types:
Wood
Material
Wood
Basalt Wool
Perlite
Polyisocyanurate
Composite Board
Wood Fiberboard
High Density Wood Fiberboard
Rockwool
Maximum Design Pressure
Maximum Fire Classification
-75psf
e
Material Design Pressure
Classification
Class 'A°
Note: Fire classifications and maximum design pressures do not reference all assemblies over all deck
types. Review system listings for design pressures and the Underwriters Laboratories Roofing
Materials Directory for Fire Classifications.
Product Control No: 97- 0804.14
•
Frank Zuloaga,
Roofing Product Control Examiner
SYSTEMS
Membrane Type: SBS
Deck Type II: Wood, Insulated, New Construction or Reroof
Deck Description: 10 / 32 " or greater plywood or wood plank
System Type A(1): Anchor sheet mechanically fastened, all layers of insulation adhered with
. : approved asphalt.
All General and System Limitations shall apply.'
Insulation Fastener Fastening Fasteners Fastener
Layer Tie Detail No. Per Board Density
(see PA 117)
One or more layers of any of the following insulations.
Approved Type(s): ACFoam -I. E'NRG'Y 2, GAFTEMP® Isotherm R, E'NRG'Y 2 Plus, GAFTEMP
Isotherm RA, GAFTEMP Isotherm RN, GAFTEMP Composite, GAFTEMP Composite A,
GAFTEMP Composite N
Minimum: 1" x 3' x 4' N/A N/A N/A N/A
Approved Type(s): ISORoc, GAFTEMP® Tapered
Minimum: 1" x 4' x 4' N/A N/A N/A N/A
Approved Type(s): High Density Wood Fiber, GAFTEMP® High Density Wood Fiber, GAFTEMP
RecoverBoard
Minimum: W' x 4' x 4' N/A N/A N/A N/A
Approved Type(s): Wood Fiber, GAFTEMP® Fiberboard
Minimum:' /" x 2' x 4' N/A N/A N/A N/A
Approved Type(s): Paroc
Minimum: '/." x 4' x 4' N/A N/A N/A N/A
Approved Type(s): Perlite, GAFTEMP® Permalite
Minimum: 'A" x 2' x 4' N/A N/A N/A N/A
Approved Type(s): Fiberglas
Minimum: 15 /16" x 4' x 4' N/A N/A N/A N/A
Approved Type(s): Permalite Tapered Roof Insulation, GAFTEMP® Isotherm Tapered
Minimum: 'A " x 2' x 4' N/A N/A N/A N/A
Approved Type(s): Tapered Isotherm R, Tapered Isotherm RA, Tapered IsothermRN, GAFTEMP
Composite Tapered, GAFTEMP Composite A Tapered, GAFTEMP Comp-�N /A osite N Tapered
Minimum:' /." x 4' x 4' N/A N/A NWA - -
� 1 . 1
✓
Page 18 of 61
Product Control No: 97- 0804,.1'4
Frank Zuloaga,
Roofing Product Control Examiner
Note: All insulation shall be adhered to the anchor sheet in full moppings of approved hot asphalt
within the EVT range and at a rate of 20-40 IbsJs Please refer to Metro-Dade County Roofing
Application Standard PA 117 for insulation attachment. Insulations listed as base layer only shall
be used only as base layers with a second layer of approved top layer insulation installed as the
final membrane substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS STRATAVENT®
perforaded laid dry or a layer of GAFTEMP® PERMALITE or wood fiber overlay board on all
isocyanurate applications.
Anchor sheet; • GAFGLAS® Ply 40, Ply 60, GAFGLAS Flex Ply" 6, #75 Base Sheet,
GAFGLAS #80 Ultima' Base Sheet, STRATAVENT® Nailable, RUBEROID
Modified Base Sheet or RUBEROID® 20 base sheet applied to the deck with
approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at
the lap staggered in two rows 12" in the field. Base sheet shall serve as anchor
sheet for attachment of insulation
Base Sheet:
Ply Sheet:
Membrane:
Surfacing:
Maximum Design
Pressure:
Maximum Fire
Classification:
Maximum Slope:
Specification No.:
Product Control No: 97 0804.14
(Optional) Install one ply of GAFGLAS® #75, GAFGLAS #80 ULTIMA' Base
Sheet, GAFGLAS® PLY 4 ®, GAFGLAS® PLY 6 ®, GAFGLAS Flex Ply' 6,
GAFGLAS® STRATAVENT® Perforated(laid dry), RUBEROID Modified Base
Sheet or RUBEROID® 20 directly over the top layer of insulation. Adhere with
any approved mopping asphalt applied within the EVT range and at a rate of 20-
40 lbs. /sq; (see General Limitation #4).
(Optional) One, two, or three plies GAFGLAS PLY 4 ®, GAFGLAS® PLY 6®
Ply or GAFGLAS Flex Ply 6 sheet adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 IbsJsq..
One or more plies of RUBEROID® 20 , RUBEROID 30, RUBEROID 30 FR
RUBEROID MOP Smooth, Ruberoid® Mop 170 FR, Ruberoid® Mop Granule.
RUBEROID MOP PLUS, RUBEROID MOP FR, RUBEROID ULTRACLAD ®,
fully adhered in an approved asphalt at an application rate of 25 Ibisq. ± 15 %.
(Optional, required if RUBEROID MOP Smooth or RUBEROID 20 is top
membrane) Install one of the following:
1. Gravel or slag applied at 400 IbJsq. and 300 lb. /sq. respectively in a flood coat
of approved asphalt at 60 lb. /sq..
2. GAFGLAS Mineral Surfaced Cap Sheet in an approved asphalt at an
application rate of 25 lb. /sq. + 15 %.
-45 psf (See General Limitation #7)
'A'. See General Limitation #2.
2 ":12 "; See General Limitation #3.
Page 19 of 61
Frank Zuloaga,
Roofing Product Control Examiner
Product Control No: 97- 0804.14
Wood Deck System Limitations:
1. Fastener spacing for anchor sheet attachment is based on a Minimum Characteristic Force (F')
of 95 lbf or greater as tested in compliance with Merto-Dade County Protocol PA 105. If F' as
tested is below 95 lbf, a professional engineer may submit a revised fastener spacing utilizing
the withdrawal resistance value taken from Metro -Dade County Protocol PA 105 and
calculations in compliance with Metro -Dade Roofing Application Stanadrd PA 117,
2 All standard insulation panel sizes are acceptable for mechanical attachment. When panels are
applied in hot asphalt, maximum panel size shall be 4' x 4'.
a. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') of
275 lbf. as tested in compliance with Merto-Dade County Protocol PA 105 & Roofing
Application Standard PA 117. If the fastener value, as field tested, are below 275-lbf. insulation
attachment shall not be acceptable.
3 A slip sheet is required with GAFGLAS FlexPly 4® and Ply 6® when used as a mechanically
fastened base or anchor sheet.
4. A Type X gypsum board is acceptable to be installed directly over the wood deck..
Frank Zuloaga,
Roofing Product Control Examiner_
GENERAL LIMITATIONS
Product Control No: 97- 0804.14
1 All asphalt shall comply with ASTM D 312 type III or type IV requirements, and
approved by applicant.
2 Fire ratings are determined by a combination of sloe deck
slope, type and assembly. Refer to
current Underwriters Roofing Materials Directory or other fire testing data listed in the
testing file. Fire ratings shall be in strict compliance with Sections 3401.5 and 3401.6 of
the South Florida Building Code. •
3 Maximum slope range shall vary for each system; consult current Underwriters
Laboratories Roofing Materials Directory and manufacturer's specifications for
compliance with design criteria for each project.
4 An overlay and/or recovery board insulation anel is
p required on all applications over .
closed cell foam insulations when the base sheet is fully mopped. If no recovery board is '
used, install one layer of GAFGLASS STRATAVENT Perforated, laid dry.A base sheet
may be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.;
or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of
the sheet allowing a continuous area of ventilation. Encircling of the strips is not
acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation.
Asphalt application of either system shall be at a minimum rate of 12 lbsJsq. Note:
Spot attached systems shall be limited to a maximum design pressure of -45 psf. Where
STRATAVENT Perforated is used over approved isocyanurate foam insulation, the
maximum design pressure is limited to — 60psf.
All work shall be performed by a contractor licensed to do roofing work in Metro - Dade
County. Contractor shall be familiar with the details and specifications published by the
manufacturer, and the requirements of the SFBC.
The submission of system specifications and details shall accompany the Section II
Building Code Permit. This information is available in the publications listed in the
'System Description° of this Product Control Approval. The submission of these
documents, as well as the proper application and installation of all materials shall be the
sole responsibility of the contractor.
Zuloaga,
Roofing Product Control Examiner
Product Control No: 97.0804.14
7 Perimeter and comer areas shall comply with the enhanced uplift pressure of these areas,
as calculated in compliance with Chapter 23 of the South Florida Building Code. Fastener
densities shall be increase for both insulation and base sheet as needed calculated in compliance
with Metro -Dade County Roofing Application Standard PA 117. (When this Iimitation is
specifically referred within this NOA, General Limitation #20 will not be applicable.)
8 All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination
designs shall conform with Metro -Dade County Roofing Application Standard PA 111
and the wind load requirements of Chapter 23 of the South Florida Building Code.
9 Flashings shall be installed according to the manufacturers standard details, and may be
applied in cold application adhesive, approved asphalt or may be applied in conjunction
with an approved torch applied modified bitumen membrane. Specific details, approved
by the manufacturer, shall be submitted with the Section II Permit Application. All details
shall comply with the provision of the South Florida Building Code.
10 Fastener spacing for base sheet attachment is based on a Minimum Characteristic Force
(F') value as tested in compliance with Metro-Dade County Protocol PA 105. If the fastener
values as tested are below those listed in the System Limitations, a professional engineer may
submit a revised fastener spacing utilizing the withdrawal resistance value taken from a Metro -
Dade County Protocol PA 105 test report and calculations that comply with the wind load
requirements of Chapter 23 of the South Florida Building Code and Roofing Application Standard
PA 117.
11 Fastener spacing for insulation attachment is based on a Minimum Characteristic Force
(F') value of 275 Ibf., as tested in compliance with PA 105. If the fastener value, as field tested,
are below 2751 bf. insulation attachment shall not be acceptable.
12 Asphalt moppings shall be with applied with approved asphalt and shall be in compliance
with equiviscous temperature (EVT) methods of asphalt determination. Asphalt containers or
bulk tickets shall indicate an EVT, finished blowing temperature (FBT) and flash point. Asphalt
types and temperature ranges shall be in compliance with Subsection 3403.4(a)(3) of the South
Florida Building Code.
13 Insulation may be installed in multiple layers. The first layer shall be attached in
compliance with Product Control Approval guidelines. All other layers shall be adhered
in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40
IbsJsq., or mechanically attached using the fastening pattern of the top layer. Refer to
manufacturer's literature and/or the NRCA Roofing and Waterproofing Manual for correct
application procedures of insulation panels in approved asphalt or adhesive, which shall
comply with provision of Roofing Application Standard PA 117
rank Zuloaga,
Roofing Product Control Examiner
.14 All standard panel sizes are acceptable for mechanical attachment. When applied in
approved asphalt, panel size shall be 4' x 4' maximum.
15 In re- covery/re- roofing applications, prior to the application, all existing roof surfaces used as a
bonding substrate shall be tested in compliance with Metro-Dade County Protocol PA 124 for
uplift resistance. Test pressures shall be calculated in compliance with the wind Toad
requirements of Chapter 23 of the South Florida Building Code to the design pressure of the roof.
16 In re -roofing applications, moisture content in an existing roof must be in compliance with
Section 3401.10(m), (n) of the South Florida Building Code.
17 Roll good materials shall be stored on end and on a clean, flat and dry surface.
18 If required, any Factory Mutual Approved vapor barrier in conjunction with proprietary or
approved adhesives may be used prior to the application of the insulation layer.
19 Consult current Underwriters Laboratories Directory for the appropriate coating for each
roofing assembly to obtain the required fire rating. The assembly shall be installed in
strict compliance with sections 3401.5 and 3401.6 of the South Florida Building Code for
maximum fire classification.
20 The maximum designed pressure limitation listed shall be applicable to all roof pressure
zones (i.e. field, perimeters, corners). No rational analysis, nor extrapolation shall be
permitted for enhanced fastening at enhanced pressure zones (Le. perimeters, extended
comers, and corners). (When this limitation is specifically referred within this NOA,
General Limitation #7 will not be applicable.)
Product Control No: 97 -0804.14
Frank Zuloaga,
Roofing Product Control Examiner
t1
R')OF COVERING MATERIALS '(TEVT)
ROOFING SYSTEMS (TGFU)= C
Gase Sheet (Optional): One or more layers Type G1, G2 or G3.
Membrane: One or more layers of "Ruberoid Torch" (smooth or granule),
'Ruberoid Torch Plus" (granule), Ruberoid Mop (granule) or "Ruberoid
Mop Pt" (g ranule).
Coating: Karnak No. 97, 1 -1/2 - 3 gal/sq.
Deck: C -15/32 Iodine: 1/2
Insulation: 0ne or more layers perlite, glass fiber, isocyanurate, urethane,
p erlite / isocyanurate composite, perlite /urethane composite, phenolic,
1 -1/2 in. min thickness (offset from plywood joints 6 in.).
Base Sheet One or more layers of Type G2 or G3.
Ply Sheet (Optional): One or more layers of Type G3.
Membrane: One or more layers of "Ruberoid Torch" (smooth or granule),
'Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or
'Ruberoid Mop Plus" (granule).
Surfacing: Karnak No. 97, 1 -1/2 - 3 gal/sq.
= Deck: NC Iodine: 1/2
Base Sheet (Optional): One or more layers of Type G1, G2 or G3.
Membrane: One or more layers of "Ruberoid Torch" (smooth or granule),
"Ruberoid Torch Plus" (granule).
Surfacing (Optional): Karnak "No. 97" or "169" at 1 -3 gal /sq or Grundy
Ind. '20 F Emulsion" at 3 gal/sq.
g. Deck: C -15/32 Incline: 1/2
Insulation: One or more layers perlite, glass fiber, 3/4 in. min,
isocyanurate, urethane, perlite /isocyanurate composite, perlite /urethane
composite, phenolic, 1 -1/2 in. min.
Base Sheet (Optional): One or more layers of Type 61, G2 or G3.
Membrane: One or more layers of "Ruberoid Torch" (smooth or granule),
'Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or
"Ruberoid Mop Plus" (granule).
Surfacing: Gravel.
i! Dec C-15/32 Incline: 1/2
Insulation (Optional): One or more layers perlite, wood fiber, glass
fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/
urethane composite, wood fiber/isocyanurate composite, phenolic
Base Sheet Two or more layers of Type G2 or G3.
Ply Sheet (Optional): One or more layers of Type G3.
Membrane: One or more layers of "Ruberoid Torch" (smooth or granule),
"Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or
"Ruberoid Mop Plus" (granule).
Surfacing: Karnak No. 97, 1 -1/2 - 3 gal/sq or graveL
8. Deck: NC Incline: 1/2
Insulation: One or more layers perlite, glass fiber, 3/4 in. min,
isocyanurate, urethane, perlite / isocyanurate composite, perlite /urethane
composite, phenolic, 1 -1/2 in. min.
Base Sheet (Optional): One or more layers of Type 61, G2 or G3.
Membrane: One or more layers of "Ruberoid Torch" (smooth or granule),
"Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or
"Ruberoid Mop Plus" (granule).
Surfacing: "AL MB Aluminum Roof Coating" at 1 -2 gal/sq.
9. Deck: C -15/32 Iodine: 1/2
Insulation (Optional): One or more layers perlite, glass fiber, 3/4 in.
min, isocyanurate, urethane, perlite /isocyanurate composite, perlite/
urethane composite, phenolic, 1 -1/2 in. min.
Base Sheet: One or more layers of Type 62 "GAFGLAS #75 Base Sheer,
hot mopped or mechanically fastened in place.
Ply Sheet One or more layers of Type 61 "GAFGLAS Ply 4 ", hot mopped
in place.
Membrane: "Ruberoid Mop FR" (granule).
Surfacing (Optional): GAF Fibered Aluminum Coating at 1 -1/2 gal/sq or
GAF Weather Coat Emulsion at 3 gal/sq.
10. Deck: C -15/32 Incline: 1/2
Insulation (Optional): One or more layers perlite, glass fiber, 3/4 in.
min, isocyanurate, urethane, perlite /isocyanurate composite, perlite/
urethane composite, phenolic, 1 -1/2 in. min.
Base Sheet One or more layers of Type G2 "GAFGLAS #75 Base Sheet",
hot mopped or mechanically fastened in place.
Ply Sheet One or more layers of Type 61 "GAFGLAS Ply 4 ", or "GAFGLAS
Ply 6" hot mopped in place.
Membrane: "Ruberoid Torch FR" (granule).
Surfacing (Optional): GAF Fibered Aluminum Coating at 1 -1/2 gal/sq or
GAT Weather Coat Emulsion at 3 gal/sq.
11. Deck C -15/32
Insulation: Isocyanurate, 2 in. min., wood fiber or glass fiber,
any thickness, hot mopped or mechanically fastened in place. Joints
offset 6 in.
Base Sheet One or more layers of Type G2 "GAFGLAS #75 Base Sheer,
hot mopped or mechanically fastened in place.
Ply Sheet (Optional): One or more layers of Type.G1 ;GAFGLAS Ply 4" or
"Ply 6" hot mopped in place.
Membrane: "Ruberoid Torch FR" (granule).
Surfacing (Optional): GAF Fibered Aluminum Coating at 1 -1/2 gal/sq or
GAF Weather Coat Emulsion at 3 gal/sq.
1
2
LOOK FOR MARK 0
ROOF COVERING MATERIALS (TEVT) 135
ROOFING SYSTEMS (TGFU)— Continued
12. Deck: C -15/32 Incline: 1/2
Insulation (Optional): Isocyanurate, perlite or glass fiber, any thickness,
hot mopped or mechanically fastened in place. Joints offset 6 in.
Base Sheet One or more layers of Type G2 "GAFGLAS #75 Base Sheer,
hot mopped or mechanically fastened in place.
Ply Sheet One or more layers of Type Gi "GAFGLAS Ply 4" or "Ply 6 ", hot
mopped in place.
Membrane: "Ruberoid Torch FR" (granule).
Surfacing (Optional): GAF Fibered Aluminum Coating at 1 -1/2 gal/sq or
GAF Weather Coat Emulsion at 3 gal/sq.
13. Deck: NC Incline: 1/2
Insulation (Optional): Isocyanurate, wood fiber board, perlite, glass
fiber, any thickness, hot mopped or mechanically fastened in place.
Joints offset 6 in.
Base Sheet One or more layers of Type G2 "GAFGLAS #75 Base Sheer,
hot mopped in place.
Ply Sheet (Optional): One or more layers of Type 61 "GAFGLAS Ply 4" or
"Ply 6" hot mopped in place.
Membrane: "Ruberoid Torch FR" (granule).
Surfacing (Optional): "GAF Fibered Aluminum Coating" at 1 -1/2 gal /sq
or GAF Weather Coat Emulsion at 3 gal/sq.
14. Deck: NC Incline: 1/2
Insulation (Optional): Isocyanurate, wood fiber board, perlite, glass
fiber, any thickness, hot mopped or mechanically fastened in place.
Joints offset 6 in.
Base Sheet One or more layers of "GAFGLAS #75 Base Sheer, hot
mopped in place.
Ply Sheet (Optional): One or more Layers of "GAF GLAS Ply 4" or "Ply 6"
hot mopped in place.
Membrane: "Ruberoid Torch FR" (granule).
Surfacing (Optional): GAF Weather Coat Emulsion applied at 3 gal/sq or
GAF Fibered Aluminum Coating at 1 -1/2 gal/sq.
15. Deco C -15/32 Incline: 1/2
Insulation (Optional): Perlite, fiber glass, isocyanurate, urethane, perlite/
isocyanurate composite or phenolic.
Base Sheet One or more layers Type G2 or G3 base sheet, hot mopped
or mechanically fastened.
Ply Sheet (Optional): One or more layers Type Gi, hot mopped in place.
Membrane: "Ruberoid Mop FR" or "Ruberoid Mop 170 FR" (granule).
16. Deck: C -15/32 Incline: 1/2
Insulation (Optional): Perlite, fiber glass, isocyanurate, urethane, perlite/
isocyanurate composite or phenolic, offset 6 in. from joints.
Base Sheet One or more layers of Type G -2 or G -3 base sheet, hot
mopped or mechanically fastened.
P Ply Sheet (Optional): One or more layers of Type G -1, hot mopped in
Membrane: One layer of "Ruberoid Torch" or "Ruberoid Mop" (smooth).
Membrane: One layer of "Ruberoid Torch FR" or "Ruberoid Mop FR"
(granule)
17. Deck: NC Incline: 1
Insulation (Optional): Perlite, fiber glass, wood fiber, isocyanurate,
urethane, perlite /isocyanurate composite or phenolic
Base Sheet One or more layers Type G2 or G3 base sheet, hot mopped
or mechanically fastened.
Ply Sheet (Optional): One or more layers Type G1, hot mopped in place.
Membrane: One layer of "Ruberoid Mop FR" or "Ruberoid Mop 170 FR"
(granule).
18. Deck: NC Incline: 1/2
Insulation (Optional): Perlite, fiber glass, wood fiber, isocyanurate,
urethane, perlite /isocyanurate composite or phenolic.
Base Sheet (Optional): One or more layers of Type G -2 or G -3 base
sheet, hot mopped or mechanically fastened.
Ply Sheet (Optional): One or more layers of Type G -1, hot mopped in
place.
Membrane: One layer of "Ruberoid Torch" (smooth), "Ruberoid Mop"
(smooth).
Membrane: One layer of "Ruberoid Torch FR", "Ruberoid Mop FR" or
"Ruberoid Mop 170 FR" (granule).
9. Deck: NC Incline: 1/2
Insulation (Optional): One or more layers of perlite, glass fiber,
isocyanurate, urethane, perlite /isocyanurate composite or phenolic, any
thickness.
Base Sheet One or more plies G1 or G2, hot mopped or adhered with
Karnak Chemical Co. "No. 81" or Gibson -Homan "No. 6160" cold applied
adhesive at 1 -1/2 gal/sq.
Membrane: One layer of "Ruberoid Mop FR" or "Ruberoid Mop 170 FR"
(ranule), hot mopped or adhered with Karnak. Chemical Co. "No. 81" or
Gibson-Homan "No. 6160" cold applied adhesive at 1 -1/2 gal/sq.
0. Deck: C -15/32 Incline: 1/4
Insulation: Polyisocyanurate, any thickness.
Base Sheet "GAFGLAS #75" (Type G2), mechanically attached.
14 PRODUCT