Loading...
ROOFINGBUILDING ELECTRICAL PLUMBING ROOFING MIAMI SHORES VILLAGE. FLORIDA ❑ PERMIT N9 6596 Owner of Building Architect Contractor or Builder Legal Lot Description I BI Address of Building CONTRACTOR OR BUILDER DATE 195 Contractor's License No. Work to be performed under this Permit Subdi- vision Value of Project $ i Amount cf Permit $ This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application horofor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed w :thout authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings cr in the statements or specifications and that he assumes responsibility for work done by his agents, servants or employees. Signed BY INSPECTOR In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In ac- cepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. BY AUTHORITY Estimated Total cost of improvements f t .u -01, "— STATE OF FLORIDA, COUNTY OF DADE. ss MIAMI S 0 ES VILLAGE UILDING INSPECTION DEPARTMENT. APPLICATION FOR U LDIN3 PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy cf approved plans and specifications must be kept at building during p gran of the work. Owner's lame and Address 0° ,� � 3 ' � f b._._ .. ._ Egm...?. ._ . S i .. ...Sf 1 i Registered Architect and /or Engineer ............. ,,:, ` and address of licensed contractoe ..f/."`:6a��'. etsf -d . . - e3Z4; Location and legal description of lot to be built on: Lot Block Subdivision Street and Number when: work is to be done 1 /616/ ' L State work to be done and urpose of buil ing„ (b floors) ..._._ 2 sa r � ..:-� .F . t°� ..., ' . 7 4 7 1 . 4 .r.- - ' � /IC .. .... -e --.. 41_,e ‘ 7 and for no other purpose. New Building Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation Pioa %; f Covering I Amount of Permit $. � 7 ` e...a Zone cubage required _Plan Cubage Distance to next nearest building Size of Building Lot be sent to... _ ✓ r-�a� '..� � C r. , � .a / e,z) Maximum live load to be borne by each floor I hereby suit a the plans and s ecificati ns for said building. All notices with reference to the building and its construction may The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida 'Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspec ': r on th site of- a work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subso� •.a - •rs,�oyl�: tt performed tinder this permit, as are licensed by Miami Shores Village. - Remarks. (Signed). Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the rote, and that al! facts therein by him stated are true. Permit No Date Read, Sworn to and Subscribed before arse. Disapproved _...._ Date.__... __._......._ __� , Notary Public, State of Florida (Signed) P %' L ..__. _ ... �_ �.__... Building Inspector ,/ My Cornaniszioa Expires to me well known, PLANNING BOARD DATE Chairman Member Mcrrsber Member Member .. .. _- •- -•-- ....._._._.._.._.._ -.- - -_ Member Council Approved Date Disapprovei! Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtainedi from the Planning hoard. A re-inspection fee of $1.00 will be charged when rwch ac- anopeetfcn is asaedt) nececary by lrrtprcper notice for inspection or faulty materials and /or workmanship. Location and legal description of lot to be built on: Lot Block Street and Number where work is to be done MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby wade for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the iuilding Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Address .M.r M......P.a113..S.e21 _......_.__ _ N ...0 - Street._9 L .s Registered Architect and /or Engineer CT ,,, ,,,,....,,,222.2_ -, .... Name and address of licensed contractor...AIla e ll.S...E.QD_fJl.Xlg....4....i Jlp1l (I..a_. GQ� 43..0.... x....1. th ... V. 'Subdivision 8 N.E. 9Sth St. State work to be done and purpose of building (by floors )...CIImp.1.e. 8..- .ro.of company, installing lead flashings on plumbing pipes and laying white flat tile on roof and for no other purpose. New Building Remodeling Addition Repairs X X No. of Stories 1 To be constructed of Kind of foundation Roof Covering wh. i- t o flat t i 1 e Estimated Total cost of improvements $ 2 7 9 0. 0 0 Amount of Permit $,. 7 2 8 S G Zone cubage required .._. .•.Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to.. Andrews Roofing E IMp. Co. 4300 E. llth Ave. Hia. 33013 The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as arc required by the Act. The undersigned agrees to employ only such subcontractors on works performed under this pennit, as are licensed by Miami Shores Village. .- Remarks (Signed) ��/� � � .. ,� , STATE OF FLORIDA, COUNTY OF DADE. i Ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are drop p / ' �- Read, Sworn to and Subscribed before me. _�(G�.1 Permit No._��;_� Date ..__ :__ .__.. _._._ Disapproved.__, Building In ector PLANNING BOARD Chairman Member Member Council Approved Membcr Member Member Date Disapproved Notary Public, State of Florida My Commission Expires DATE NOTE: A charge of $1.00 will be made for making corrections the Planning Board. A rc- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice materials and /or workmanship. or changes to this application after approval to me well known, Date has hecn obtained from for inspection or faulty Date 1 -19 -94 Job Address 1080 N.E. Square Ft. Signature of owner Date: / —l9 -q Notary as tti Owner My Commission Expi7 PERMIT APPLICATION FOR MIAMI SHORES VILLAGE and /or Condo President f 7, . MARYLOU HERN • EZ °; MY COMMISSION # CC 324212 EXPIRES: October 10, 1997 of \' Bonded Thru Notary Public Underwriters oto Paulsen * f 95th Street Tax Folio /7 � A%:!5i0 / 0i,o. . e.0 Legal Description 7 . Owner / Lessee / Tenant Mr. Owner's Address 1080 N.E. 95th Street Phone 754 - 3806 Master Permit 1t r3 `�,t's. d✓3 Contracting Co. (? JQ l °ty Rae[ N9 e4A//{a ,_L41(, Address a 5 / /vci} 9 9 'S Qualifier CAr/D S Rroc O SS# Phone 76/- 3 g State -IP C 0 5 ktOMunicipal # 07 C0? Competency # /7 ` 9 Ins.Co. Architect /Engineer Address Bonding Company 6 Address Mortgagor Address Permit Type(circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL _ 84QPING_ PAVING FENCE SIGt WORK DESCRI UR N Tear off roof to wood deck, tin cap 30 7b. astm felt as per hiildinc • Mop on with hot asphalt 1 laver of 901b astm felt arvd install T iles . 1.A-t 'c l 4* 4 - ' t € . r sc/ . Estimated Cost(value) [2,500 t ;o WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO IN SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTENT TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUI NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, an on the attached addendum (if applicable). I certify that all work will be performed to meet th standards of all laws regulating construction in this jurisdiction. I understand that separat permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work wil be done in compliance with all applicable laws regulating construction and zoning. Furthermore, aut orize the above-named contractor to do the work stated. * * * Signature of Contractor or Owner- Builder Date: / /9-. Notary as to My Commission * ontctor or Owner -Bun MARYLOU HERNANDEZ MY COMMISSION # CC 324212 EXPIRES: October 10, 1997 1 :4 ` °•O Bonded Thru Vary Pub% Umurwtters FEES: PERMIT . RADON C.C.F. el.i NOTARY TOTAL DUE ' APPROVED: Fire Zoning Buildin_ C Electrical Mechanical Plumbing Engineering Other Volume 2.1 METRO - DADE BUILDING & ZONING ROOFING APPROVED APPLICATIONS JULY, 1993 SHINGLES Up to this date, only Malarkey SBS shingles have been approved to be installed in Dade County. Obtain Notice of Acceptance prior to the Installation of thls shingle. More Information will be made available as it is obtained from the Code Compliance Dept. Two (2) piles of #30 ASTM D - 226 are required at this time. Also tin caps 6" o.c. on laps and 12" o.c. on field. Any of this information is subject to change without notice. These are only GUIDELINES. Manufacturers specifications and Notice of Acceptance sheet must be placed at jobslte. Also no "Improving' Is allowed. Work must be done as per Notice of Acceptance. Ceramlca de Esparta (Nail -On System) Clay: Spanish "S' Tile Prodek, Inc. (Nail -On & Mortar Set Systems) Vulcan Clay: Spanish "S' Tile La Mancha Tiles: (Nail -On & Mortar Set Systems) Clay: Spanish "S" Tile Metro Roof Tile: (Nail -On System) Spanish "S" Cement Flat (Mortar Set) Best Clay Tile Corp.: (Mortar Set Systems) Spanish "S" 'Venezuela, S.A. Clay: "S" 'Salvador, S.A." BUILT -UP ROOF REQUIREMENTS: 1) Moisture test mandatory on any recovery. 2) Uplift test on any recovery. 3) No hot mopping of felts directly to Iso- Board. 4) System must meet 1 -90 requirements. You may refer to Factory Mutual or provide a lab tested system that will meet or exceed this requirement. (not required for wood deck) 5) Inctall an approved bane sheet. TILES Lifetlle (Nall-On Systems) ' Cement: Colonial Slate Flat Espafta "S' Style Capri Almar (USA), Inc.: (Nail -On & Mortar Set Systems) Clay: Altusa "S' Tile Altusa Barrel F.R. Bofja , Ploneor Concrete Tlle: (Nall -On Systems) 2:12 pitch Cement: Hadenda' Shake/Slate Rustic Shake Spanish "S Flat 9" Classic 100 • Entegra Roof Tile: (Nail -On System) 2:12 pitch Cement: Estate Skandia Bender Roof Tile Ind.,Inc. (Nall -On System) 2:12 pitch Cement : Palermo Corrugated Nordic Flat Etema Roof Tile Manufacturing (Nall -On Systems) Cement: Estate Barrel Skandla Flat Marley Roof Tile: (Nail -On Systems) Cement Barcelona Castillo Monier Roof Tile: (Nail -On Systems) 2:12 pitch Cement: Mission Cement • Villa Flat Shake & Slate Vanguard 11 Roll Spanish "S" . Vanguard 11 Flat Classic "100' The tile shall be installed on a solid nailable dock of 5/6" thick plywood for all new construction or to 1/2' plywood deck on re- roofing. , • 'The nailable deck shall be covered with a #30 Type 11 (ASTM 226) anchor sheet maintaining a 4" overlap and tin - capped 12' o.c. except 6' o.c. at the laps. Over this, a #90 mineral surface roll roofing shall be fully hot - mopped with nominal 2' l aps with the concealed edge of lap tin- capped 12" o.c. except at the valley flashing. The galvanized steel strip shall be nailed over the #30 anchor sheet ® 4" o.c. and over lapped for 5'. When required. and prior to the Installation of the tile, a formed 0.019 thick steel bird stop shall be Installed at the Dave, which shall be bedded in mastic to the membrane and hand nailed to the roof 11" o.c. and near each end. The tile, maintaining a 3" head lap, shall be attached with two 10d plated steel gun nags per tile over a bed of roofing mastic applied to the #90 roll roofing, at nail penetrations. The eave tile, in addition to the 2 -10d nails, shall be attached with formed steel grip clips (refer to ModraCatalog page ;--.) c entered 4 3/4" from the noso of each tile. The clips shall be 0.043" thick by 1/2" wide, galvanized steel. attached with ono 10d galvanized steel hand driven nail located 1' from the 90 degree bend In the clip. The clip shall be inbedded In mastic applied to the roofing, at tho nail location. STRONG RECOMMENDATIONS: On commercial applications a continuous cleat Is strongly recommended both by manufacturers and the Building and Zoning Department. This detail is found on almost every manufacturer specification and the FM guldelines for perimeter flashing. 9 9.'28/93 10:20 =DADE GD: co C: kunlprudrocslmeiro2 Metro Roof Tile Gtouo . i u 2908 CODE COMPLIANCE Revised 305 558 2608 P.01 METROPOLITAN DADE COLIN FLORIDA METRO-DARE NLAG;LER BUILDING BUILDING CODE COMPLIANCE DEPARTMENT SUlfE 1603 METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, rLU11IUA 33130.1563 (305) 375.2901 FAX (305) 375 -2908 September 23, 1993 Metro Roof Tile Corporation has filed with this office the additional and required acceptable test dater to support the request for renewal and continued use of ticeir'1tt;1"'Ict;�:' yf LLk 'Q.C._l .U3t11;t j-set. vs'1&m. 1he tilt shall be installed on a solid nailable roof deck of 5/8" thick plywood for all new construction or to 1/2 " plywood deck on re- roofing. :IN prepared deck shall consist of an underlayment (anchor sheet) conforming to No. 30 Type 11 (ASTM D -226) and tin capped 6" o.c. �n all laps, 12" o.c. in the, /field and 4" on drip edge over this, a hot - mopped 90 # AS1'M /-249 granular surface cap sheet by T amko, or equal is applied. The tile shall be apl.lied with a 2" head lap W the roof with the mortar consisting of Rinker Roof Tile Cement mixed with sand conforming to AS.TMC -144 for a 3.1 mix, The tiles shall be wet and set using approximately one full trowel; of mortar. Due to Hurricane Andrew, this office has been inundated.with requests for both new products and renewals of those to expire which has caused a lart4 back log in responding with an official Notice of Acceptance. In the interim period, please accept letter in allowing these products to be installed by a licensed roofing contractor in accordance with the manufacturer's further specifications and Chapter 34 of the South Florida Building Code until an official Notice of Acceptance is issued Sincerely yo I/01r 'il Diamond, 1'.1: Product Control Division Supervisor Post -it'" Lrand fax transmittal memo 7671 i# of Poges ■ , 7 To = � Fr om � r .tc r1 s ic, ,. � _Yci Co. Co. Cal 00 • Nato hoof '1'lle, Ina. 11350 N.H. SouU•h River Vrlve :' Medley, FLT 331'l8. lout: application for Product Approval of Le1ue. 111:J E. lca .L1tVUTl..,in.e. ..__.... under Sections 203 nncf 204 of the South Floridn building Code yovot the use of Alternate Materials and Typos of Construction, and comp: described In the plans, specifications and calculations as nuhmit. �I. cII1�. ..__alu�iy__rc.l�t<1a__I�gn14 � po.r_t_da.te u..l,auulte __ 1.51 hnn been acce by Product Control to be need in the II L LI$c:urtIorh: ntens of Dade County under the Speulfiu Cetidillons set forth on pa; 1 -2a and the Standard Condit/ono on Page 3 ACCEPTANCE Ho.I APPROVED EXPIRES Metro Roof Tile 305 558 2608 1 :1:UIfl ],;a .J;1JJ nastitlt SllEi1 £l.J_.._._E1ltIL1lt,IL?J.'ll ttllLMG#1E111t�.UZ1 CIFIC_Xlu._t. Oxitumituaa_affiLauroata_tiaxicp_ucuettskics This application for Product Approval has been accepted by t.l1v It lropolltan Dade County Board of Rules and Appeals to be used in Incorporated and Unincorporated area of Dade County under the coo: set forth above. A1'YIIUVEDI 1tuY�1ui I.' 1X kith J(11' COM'1'HUL ilitl:Cilat. lid itaa jk1 • No'T`o4& /1_ . i J i 1 amOJ%d k '.1,. ruduut Control Supel:vlb;:• Metropolitan Uncle County 13uildlny & Zu111ny UeparU .. P.02 w ME 111U•UAUS HUILUIHU & ZU111i10 LErAtfi M1x1110•1)AIit ttt ti.w, mar e; ;: • MIAMI, rL HtIUA a31i r (305) 375w;it': ( s M. iilau, E . Deputy Secretary Metropolitan Dade County Board of Rules and Appeals 4 .•, 1 i •, 1. This approves r vea flat cement tile as conforming to lieu r ' i 34Uel the South Florida Building Coda . 2. The the shall be installed in aouiormanae with 8outioJ►a 34(i< the South Florida Building Cude.t . • • 3. The the shall conform try',the tulloWittg1 1i i 1144 tiara. A • A ' •Y Metro Roof Tile 31:5 558 2608 t P. i3 • S4( t'ruduut Control. ttpervJLUI : -Motto olitan Undo County UUlld ity & Zvnlny ...., Tile • 305 558 2608 .4118No‘o IX 1r 4 411■4114.4114 &VW lt APPROVED s _ EXPIRBB $ ._,Itair.L....1.14,13.1,i / . . , BUTIUMJILACCiETARCEIAREQUIC coNDITIWW ; 1 . . • 4. gauh tile shall be identified by the marking, HSTRU ROOF TIM • • . 4,. 5 . WILALL14-• .; ••• : ,••• • 1. ' ' • ' The permitteeehall retain the services of a an indepenaent laboratory to maintain quality control. Testing shall be pekto on a minimum of five (5) tiles. Tile shall be selected by AJ1 1J-3665. selection ehall be made periodically from domestic tj. The tile shell be tested for strength according to Section 3401 the South Florida Building Code and for moisture absorption according to ASTM C-4. The test reports shall identify the a description of the tile an well an the Notice of Acceptanoe number. Test reports shall be transmitted to the Dade County Product Control Section every ninety (90) days. If no test lop, aru received within a one hundred twenty (120) day period, the Notice of Acceptance will 'be considered as being abandoned and • approval will be cancelled without. notice%to the permitteo. Reinstatement will require a new application and Lull Lee. 6. This renewal uupersedes Notice of Acceptance •07-0901.1 datod October 19, 1987. P.04 r 7444411 - 2 " i " -44 --* ••,:. 1 . 1 2 i' • • .1 A 1' 1. efe-nr,- amond, PAC. Product Control Supervisor Metropolitan Dade County Building & Zoning Vepartment 4 . 4 • • . • , .*•■■••••■•••■ METRO ROOF 711:LJE, INC. FLAT Metro Roof Tile MANUFACTURERS OF CEMENT ROOF 'PILES 11501 N.W. 117 WAY. MEDLEY. PI. 33178. II.CA. TELLNIIONES 305 558.6712 • 55(1.671 WAVE (NFW PROFILE) 305 558 2608 P.05 MORTARSFT APPROV]ED ➢3 °, ADE COUNT) SPA. NISH H "S" 0 1/00/94 09:32 e305 373 2908 MARGON -S.A. TILE: 1501 E. Hallandale I3eacli Blvd. Unit (123) IIalla.ndale, Fl 33009 William Foxstanetta (305) 456 -8146 MARLEIRODElljaa Metro Roof Tile MCC 1! ARBLl+ CEI2AMI cEsaE1 : 9820 NW 77 Avenue IIialeah Gardens, Florida 33026 Phone 823 -0990 Fax 826 -5473 l�l t.TR -lEM ROOF Tii .li 11501 NW 117 Way Medly, Fl 33178 Phone 305 -558 -6712 Fax 305 -558 -2608 mEmiliumuji 11350 NW S. River Drive Medley, FL 33178 558 -6712 558 -2608 PAGE4 CODE COMPLIANCE 305 558 2608 P.06 (Nail -On & Mortor Set) Clay Tile: i'elha Musa Clay Spanish "S" (Nail -On Systems) Cement Tile: Barcelona Castillo (Nail -On & Mortar -Set Systems) Clay Tile: Interlocking Spanish "S" (Antonio Ramon 13orja) (Mortar -Set System) Clay Tile: Curved 13arrel Clay Tile (Antonio Ramon 13orja) ( Mortor Set) Cement Tile: Wave Double Roll (Nail -On & Mortar Set) Cement Tile: , Spanish "S" (Mortar Set System) Cement Tile: Flat Do. Metro Roof Tile METRO ROOF, .. TILE 1131;;0 N.W. S0U'1 "r•I ~ � MEDLEY , • FLORIDA :•�33 f2 DIZ VE 178 COI1PLL1-E YNST'ALLAT'TUN • . -_.. ZNSTrRUCrroN yr_pE2 FLAT � 'TZL(~ 1. CHEcK 1 /�? ROOF PROPERLY THE FIRST RUN • . (ND 3/4 INCHES OVER THE N CAN O THER �� BETWEEN ' LINES SHOULD E MARKED, AT EDG . TL ALL OTHER HORIZONTAL' 14.0 INCHES. TLES a) THE HAS , TO OE WET PRIOR TO (1 HE , IS PERHAPS INSTITOATION . IDEAL TIME TO WET . • _ THE �Esr WAY To 'H 'xNS7' THE IS DO IT. A LATION. � !four? PRIOR b) THE MORTAR HAS 7'o BE r: RESH AND HOULD WITHIN ONE HOUR AFTER BEING MADE, TI U� ' TO CEMENT '('p S �CC� SAN IS l AND '3;1 , A RATION Of= APPLIED VERTICALLY WHERE THEETWOTI IE CAVITIES OF THE TILE ARE LOCATED, A'f:UL . . 0 r 10 WILL RE: SUFFICIENT FOR; THE:•,708. ' IT WILL TAKE E3E•rWEEN 5 L rr <Gwt�r.. AMOUNT AND b' POUNDS OF. MORTAR ENOUGH OF MORTAR SHOULD SE APPLIED f O rzLL THE CAVITIES. AS THE .TILE 'IS BEING PLACED' ROOF, I'r SHOULD SQUEE ON THE c) THE IL r • zE SOAK ; BEING PLACED U SHOULD 'NOT ; . �; BEEN SET' I'N P E WACKED:•0�(�''AI"TER .IT HAS LACE; UP TO ` AT. LE'AST :'S : DAYS ITS INTIAL PLACEMENT DAY d) AFTER ED , • AFTER AFTER CE�ECI~p THE S THE ' RO0F �13tw : CAN '': + R ANY LOOSE ' TILES CL EANER A STALLED PROPERLY; IF ThtAT�'WERE =� N07 IN� ETALLE GLUE. ANY .ARE 'T0; 8 C •'FOUND SUCH AS RT 604 CAN SE TO FIX THE LOOSE TILr�S . ' • • • 2. THE TILES ARE a SING M • : ANUFACTURED IN' MI • 1135 SOUTH 0 N.W. : .�.: •, .... ... .. ,. RIVER . FLORIDA 33I7 DRIVE MEDLEY •: