Loading...
ROOFINGApplication is hereby wade for the approval of the detailed statement of toe plans and specifications herewith submitted for the build • ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. C. ) v ' Registered Architect and /or Engineer..` . .... 7 Owner's Name and Address STATE OF FLOP,IDA, COUNTY OF DADE. Disapproved k (Signed) ss. MIAMI SHORES VILLAGE Date BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT 5tftC Date. Name and address of licensed contractor Location and legal description of lot to be built on: Lot mock Subdivision n � Street and Number where work is to be done .. .. . .._ ...._. ( .... v .. State work to be done and purpose of building (by floors) r. ..... 3° _.._. - and for no other purpose. New Building Remodeling Addition Repairs ,... No. of Stories To be constructed of , Kind of fouun atir., Roof vering Estimate Total cost of improvements $ \P / t ' Amount of Permit $..ZO.L'JZ .Plan Cubage Remarks.., . ( Signe • No...l..4 Street._ � 'S Notary Public, State of Florida Building Inspector My Commission Expires • PLANNING BOARD DATE Chairman Member Member Member Member .. .. Member Council Approved Date Disapproved _......_ ... .......... Zone cubage required Distance to next nearest building.. Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to.. The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied ss ith the provisions thereof, and will require similar compliance From all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for' spection on the site of the work s h public notice or noticcs as arc required by the Act. The undersigned agrees to employ only such s � ntractors, o. ork to be pe ed under this permit, as are licensed by Miami Shores Village. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, said that all facts therein by him stated ted true. Permit No../.` . .:,., Date Read, Sworn to and Subscribed before me. Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has hewn obtained from the 1'lannir, l;o.trd. A re fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection qe faulty materials and /or workmanship. Date t. - Zl -q7 PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Job Address I b) O q cr Tax Folio Legal Description Owner/Lessee / Tenant - 5 - 4 4 4 2,4);_ R.414. Owner's Address (n ?0 Contracting Co. Mark 4c Co4Sm„Cr oa Address c3C,,31 St, 7l AV Qualifier 1�; �j SS# $ ZPhone 271-3SQg State # Municipal # Competency # COO/ 9 Ins. Co. Sc.d •n512Atr_ Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICA ROOFIN PAVING FENCE ' SIGN WORK DESCRIPTION P.S.— ��1 , f�l.�►.,.4� (v ti14 • S r Cocoa ¢tit eLQ y - Aril AfucR,n/ Square Ft. Zl r Estimated Cost (value) l2 000 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. Notary as My Co FEES: PERMIT RADON ture of owner and/or Condo President Date '/3-97 9r, or Cp�ldo President Date x es:1 ;-5 'P riERRY ` # CC621289 -E - EXPt°ES MAR 02, 2007 OF FL BONDGD THROUGH ATLANTIC BONDING CO„ INC. Historically Designated: Yes No 1( Si _.'S'" a of ontract o df er- Builder Z./4/j- - Tiff • C ., r -Ekcrivr.rCHERRY issicn i i ` C S e J,# CC621289 EXPIRES MAR 02, 2001 BONDED THROUGH ATLANTIC BONDING CO., INC. Master Permit # 11/54(6. Phone - 751_ OS$/ BOND ' ?a' TOTAL DU Date APPROVED: Zoning Bfilding // " 1 . Electrical Mechanical Plumbing Engineering NOTICE OF COMMENCEMENT PERMIT NO. TAX FOLIO NO. 1) - ? j WS' 01 2. 0o; STATE OF FLORIDA: COUNTY OF DADE: 97R 193545 1997 MAY 06 12:01 7VE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: PO Nti, q'S S Lkk( *WA 6- 2. Description of improvement: Q fz - 9 kwrflies. 3. Owner(s) name and address: 4444. Nrutak la 44.. qc ST Interest in property: Name and address of fee simple titleholder: 4. Contractor's name and address: ATE 01 KOWA. VF .. s ®r flifs e? 5. Surety:(Payment bond required by owner from contractor e a fi r i le NEol Po Oleo go Name and address: Amount of bond $ 6. Lender's name and address: by Section 713.13(1)(a)7., Florida Statutes, Name and address: Siena re of Owner Pr Owners Name Sworn to and subih Notary Public %Of fp Print Notary's Name My Commission Expires: i a0 DA. 3 -A 2- Loo/ 4 t'!6 IJ S e: l. vNe. s r ,R, �f �. oontk1 6�A��a� �' 7. Persons within the State of Florida designated by Owner upon whom notices or otherrdocuments be setved as provided . Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) Prepared by: ---- )t) d go VP. 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: Address: cA(4/ ,sz 7 7 Ax. ,47 / / 33/51, Contractor's Name: ad gDtV6 . Job Address: M70 44. 3C r ROOF CATEGORY �/ ❑ (Low Slope Application) ❑ (Nail -On Tile) lJ (Mortar- Adhesive Set Tile) ❑ (Asphalt/Fiberglass Shingles) ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other) — ROOF TYPE ❑ New Roof 2 Re roofing ❑ Recovering ❑ Repair ❑ Maintenance Flat Roof Area (ft Sloped Roof Area (ft 2100 Total (ft2) V DD Master Permit No. Exposure category (per ASCE 7 -88): (% Building Classification category (per ASCE 7 -88 table 1): II Ft. n V Ft. A V Deck type: iy.10 �t i ATTACHMENT f Fastener Type: / i / QS ,� l.0 SPACING r Field: 1 ?i Perimeter: Corner: DETAIL 1 & 2 ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed) ROOF PLAN 123.01 -78 9/96 Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. Page -1 Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. Page -2 Rid e V ntilation? MEAN HEIGHT Deck type: 13� (Pmaxl: I,,,,LD x X (Aerodynamic Multiplier): I)6 tJ=Sote r z Underlayment: Insulation: 12" , ROOF SLOPI D E T A I L 3 (Pmax3: x X (Aerodynamic Multiplier): ) - M SLOPED SYSTEM DESCRIPTION A-SINA 7,6 Fastener type & spacing: MM. Cap Sheet: �(� ► Roof Covering: - Drip edge: TILE CALCULATIONS ) - M = M h,t9 PCA: 3t.< (Pmax2: x a, (Aerodynamic Multiplier): ) - M _ = M PCA: = M ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals PCA: 1' METRO -DADS r.o_ PRODUCT CONTROL ■OTICE OF' ACCEPTANCE, :ONCE, Altusa Tile, Afmar (USA), Inc. 6645 Northwest 77th Avenue Miami, FL 33166 . Your application for Product Approval of A ltusa Tile' ail -On, Mortar Set or Adhesive Set One Piece "S" Tile Roofing Tile under Chapter 3 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Redland Technologies, The Center for Applied Engineering, Inc. has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions set forth on pages 2 -16 and the standard conditions on page 17. This approval.shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. if this product or material fails to perform in the approved manner, the Building Code Compliance Office may revoke, modify, cr suspend the use of such product or material immediately. The Building Code Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the S th Florida Building Code. The expense of such testing will be incurred by the manufacturer. ACCEPTANCE NO.: 96- 1030.03 Renews 93- 0914.0 EXPIRES: 02/13/00 Raul Rodriguez Product Control Division Supervisor THiS IS THE COVERSHEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE CO_ INUTTEE This application for Product Approval has been reviewed by the Metropolitan Dade County B din Compliance Office and approved by t' dig Code Code PP n' 3uil�m�• Coy._ Committee to be u�•�•' in G-ide County, F' / -��1 under the conditions set forth above. APPROVED :02 /13197 P 'IE T R OPOL,WA,N DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDiN; BUILDING CODE COMPLIANCE OFFICE SUiTE 1603 METRO DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305)- 375 -2908 INTERNET: mdcc0l rb shadow.net PRODUCT CONTROL SECTION (305) 375-2902 FAX (305) 372 -6339 Charles Danger, P.E. Director Building Code Compliance Dept. Metropolitan Dade County Applicant: Altusa Tile Alfareria del Turbio, S.A. Barquisimeto, Venezuela PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING SYSTEM APPROVAL Category: Prepared Roofing Sub- Cateeorv: Tile Type: Nail -on /Mortar Set/Adhesive Set Sub -Type: Clay System Description Product Co, Product Control No.: 96- 1030.03 Approval Date: February 13,199', Expiration Date: February 13. 2000 Alfareria del Turbio, S.A. (Altusa), located in Barquisimeto, Venezuela, manufacturers clay roof tile for nail -on, mortar set or adhesive set applications. All tile is manufactured from natural Venezuelan clays. This Product Control Approval relates to A ltusa's "Altusa S" tile profile. Refer to appropriate Product Control Approvals for other tile profiles. The "Altusa S" tile profile is available in a variety of natural clay colors and has matching trim pieces used for rake hip, ridge hip, and valley terminations. These accessories are manufactured for all profiles and form a part of this Product Control Approval. Optional rubber or clay gave closures are also available. _. Altusa roof tiles have been tested in compliance with the South Florida Building Code requirements for clay, nail -on, mortar set or adhesive set tile applications. The minimum roof slope for the "Altusa S" nail -on tiles shall be 2 ":12 ". See the "Profile Drawing" section in this approval for the "Altusa S" profile drawing. The "Altusa S" profile has been tested for both wind characteristics and static uplift performance, therefore, any consideration for installation shall be done as a 'Moment Based System'. Data for attachment calculations is noted in Tables 1 through 4 of this Approval. Almar (USA), Inc., located in Miami, Florida, is the sole approved importer under contract for selling and distributing Altusa products in the South Florida jurisdiction. Contact: Carlos J. Fernandez General Manager Altusa Tile, Almar (USA), Inc. 6645 No!thwest 77th Avenue Miami, FL 33166 (305) 471 -5830 Frank Zuloaga Plans Examiner, Product'Control Division T ri(n Pieces Test Product Product Dimensions Specifications Description Altusa One Piece "S" I = IS" PA 112 High profile clay roof tile for direc,' Tile w = 1 ") deck or battened nail -on, mortar or '/-" thick adhesive set applications. Head -lap min. Exposure max. 15%" Product C TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT 1= varies w = varies PA 112 Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Frank Zuloaga Plans Examiner, Product Control Division Test Product Product Dimensions Specifications Description Manufacturer 430 Felt N/A ASTM D 226 Saturated organic felt o �� generic ' type 11 to be used as a nailed anchor sheet. 443 Coated Base N/A ASTM D 2626 Saturated and coated Sheet organic base sheet for single or double ply underlayment. Mineral Surface Cap Sheet Lenzingtex -ZB 140 Underiayment Rainproof 11 Ice and Water Shield Flashing Cement Product Control No.: 96- 1030.03 r TRADE NAMES OF PRODUCTS MANUFACTURED OT>-IERS N/A ASTM D 249 Mineral surfaced asphalt roll roofing for use as a top ply in a double ply underlayment system. 59" x 164' roll PA 104 Single ply, nail -on Lenzing 22 lbs/roll. underlayment. Performance, Inc. with current PCA 30" x 75' roll 36 "x75'roll or 60" x 75' roll PA 104 36'' x 75' roll PA 103 Sin;ie ply, nail -on underlayment with 2" self-adhering top ed22e. Self - adhering underlayment for use as a top ply in a two ply underlayment system with Approved 430 or 443 as the base layer. a mech. attached base sheet in a double olv underlayment system. N/A ASTM D 45S6 Cut back, asphalt generic based, asbestos free, fiber reinforced, trowel grade cement for repair and flashing applications. Frank Zuloaga Plans Examiner, Product Control Division generic generic Protect -O -Wrap, Inc. with current PCA W.R. Grace Co. with current PCA Mopping Asphalt N/A ASTM D 312 Asphalt for bonding a generic type lit or IV mineral surface cap to Test Product Product Dimensions Specifications Description Manufacturer Asphalt Primer N/A ASTM D 4 I Cut back, asphalt g eneric based coating used to facilitate bonding of dissimilar materials. Roofing Nails Tin Caps Wood Battens Roof Tile Mortar ( "TileTiteT" "). min. 12 ga. w/th ?/," head min. 32 ga. min. l' /," o.d. max. 2" o.d. vertical min. 1 „ `4 ,' horizontal min. 1" x 4" for use with vertical battens or min. 1" x 2" for use alone PA 114 Appendix E PA 114 Appendix E Wood Preservers Institute LP - 2 NiA PA 123 Annular ring shank, hot dipped, electro or mechanically gale. roofing nails for use m underlavment attachment. Corrosion resistant circular disc for use in underlavment attachment Salt pressure treated or decay resistant lumber battens Hurricane Clip & Clips PA 114 Corrosion resistant Fasteners min. width Appendix E bronze, aluminum, min. 0.062" thick stainless steel, galvanized steel or Clip Fasteners plastic attachment min. Sd x 1'' /." clips for supplemental tile attachment. Clips are installed with corrosion resistant roofing nails compatible with the clip. A hurricane clip is required on all nail - on eave tiles. Prepared mortar mix designed for mortar set roof tile applications. Frank Zuloaga Plans Examiner, Product Control Division Product Control No.: 96- 1030.03 generic generic generic generic Bermuda Roof Company, Inc. with current PCA Product Roof Tile Mortar ( "Quikrete® Roof Tile Mortar #1140") Roof Tile Adhesive ( "Polypro® AH 160") Valley Flashing Drip Edge Dimensions N/A N/A min. 26 ga. min. 16" width 1 min. 26 ga. min. 2" face flange min. 2" deck flange w Test Specifications PA 123 See PCA ASTMI A 525 PA 111 Product Description Prepared mortar mix designed for mortar set roof tile applications. Two component polyurethane adhesive designed for adhesive set roof tile applications. Galvanized steel valley flashing Galvanized steel drip edge Frank Z u loaga Plans Examiner, Product Control Division Product Control No.: 96- 1030.03 Manufacturer Quikrete Construction Products with current PCA Polyfoam Products, Inc. with current PCA generic generic Test Agency Tesrwell Craig Laboratories Ez Consultants, Inc. Redland Technologies Redland Technologies Redland Technologies L. The Center fQr Applied 94 -034 Engineering, Inc. Test Identifier Lab. g:\A ? -2 7161 -03 Appendix 111 7161 -03 Appendix 11 . The Center for Applied 25- 7200 -1 Engineering, Inc. The Center for Applied Project No. 307025 TEST REPORTS Test Name/Report Date - ASTM 1167 Oct. 1994 Static Uplift Testing Dec. 1991 PA 102 Wind Tunnel Testing Dec. 1991 PA 108 (Nail -On) Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 PA 108 (Nail -On) Redland Technologies P0631 -01 Wind Tunnel Testing July 1994 PA 108 (Mortar Set) Rediand Technologies PO402 Withdrawal Resistance Testing Sept. 1993 of screw vs. smooth shank nails Redland Technologies - • 7161 -03 Static Uplift Testing Dec. 1991 Appendix 111 PA 102(A) The Center for Applied 94 -83 Static Uplift Testing April ,1994 Engineering, Inc. PA 101 (Adhesive Set) Static Uplift Testing PA 101 • (Mortar Set) Static Uplift Testing PA 102 (Quick -Drive Screws, Battens) Wind Driven Rain Oct. 1994 Engineering, Inc. Test 4N1DC -7S PA 100 Frank Zuloaga Plans Examiner, Produc: Control Division Product Control No.: 96- 1030.03 May 1994 Feb. 1995 Deck Type: wood, Nor.- insulated Vertical Battens: Horizontal Battens: Roofing Tile: Comments: SYSTEMS Deck Description: New Construction f / or greater plywood or wood plank. SYSTEM A: Counter -Batten Application Product Control No.: 96- 1030.03 it Slope Range: 2': 12" to 7 " :12" Note: Counter - Battens, as noted below, are required for slope range 2 ":12" to less than 4 ":12" and are optional for slopes of 4 ":12" to 7 " :12 ". For slopes exceeding 7 ":12 ", refer to System C. Underlayment: Install underlayment system in compliance with Dade County Application Standard PA 1 1 S. Install vertical battens in compliance with Dade County Application Standard PA l I S Install horizontal battens in compliance with Dade County Application Standard PA I I S. Install tile in compliance with Dade County Application Standard PA I IS. (See "Data for Attachment Calculations" included in this Approval.) I. For re -roof applications, ' / plywood is an acceptable substrate. Frank Zuloaga Plans Examiner, Product Control Division SYSTEMS (CO`TINUED) Deck Type: Wood, Non - insulated Deck Description: New construction ' /;," or greater plywood or wood plank. SYSTEM B: Direct Deck Application Product Control No.: 96- 1030.03 Slope Range: 4":! 2" to 7 ":1 Note: System B is only acceptable in this slope range. For slopes less than 4 ":12 ", refer to System A. For slopes in excess of 7 ":12 ", refer to System C. Underlayment: Roofing Tile: Comments: Install underlayment system in compliance with Dade County Application Standard PA 118. Install tile in compliance with Dade County Application Standard PA 118. (See "Data for Attachment Calculations" included in this Approval.) 1. For re -roof applications, 'S/ plywood is an acceptable substrate. Frank Zuloaga Plans Examiner, Product Control Division SYSTEMS (CONTINUED) Deck Type: Wood, Non - insulated Deck Description: New constriction " /}," or greater plywood or wood plank. SYSTEM C: Horizontal Batten Application Slope Range: 4":12" or greater Note: Horizontal battens, as noted below, are required for slopes in excess of 7 ":12" and are optional for slopes of 4 ":12" to 7 ":12 ". For slopes less than 4":12 ", refer to System A. Undcrlayment: Roofing, Tile: Product Control No.: 96- 1030.03 Install underlayment system in compliance Nvith Dade County Application . Standard PA 119. Horizontal Battens: Install horizontal battens in compliance with Dade County Application Standard PA 1 19. Install tile in compliance with Dade County Application Standard PA 119. (See "Data for Attachment Calculations" included in this Approval.) Comments: 1. For re -roof applications, 15 1 3 ," plywood is an acceptable substrate. Frank Zuloaga Plans Examiner, Product Control Division Deck Type: Deck Description: SYSTEM D: Slope Range: Roofing Tile: Comments: Wood, Non - insulated SYSTEMS (CONTINUED) New construction 19 /,," or greater plywood or wood plank. 1 :Mortar or Adhesive Set Application 2' : l 2' to 7' : i 2' Note: System D is only acceptable in this slope range. For slopes in excess of 7 ":12 ", refer to System C. Undertayment: Install underlayment system in compliance with Dade County ,Application Standard PA 120. (See System Limitation #5.) Install tile in compliance with Dade County Application Standard PA 120. (See "Data for Attachment Calculations" included in this Approval.) 1. For re -roof applications, ' plywood is an acceptable substrate. Frank Zuloaga Plans Examiner, Product Control Division Product Control No.: 96 1030.03 tr Altusa 'S' Tile Tile Profile (Altusa 'S' Tile Tile Profile Altusa 'S' Tile Altusa 'S' Tile Tile Profile 1 DATA FOR ATTACHMENT CALCULATIONS Table 1: Aerodynamic Multipliers - X (ft') (ft') Batten Application 0.29 Table 2: Restoring Moments due to Gravity - M (ft-lbf) from PA 102 Testing 3 ":12" I 4 ":12" $ or less Battens Direct I Battens Direct Battens + Direct Deck Deck I Deck 4.47 I 5.35 1 4.40 5.27 1 4.31 5.16 6 ":12" Battens i Direct Battens Direct Deck Deck 4.20 1 5.0S 4.08 I N/A Table 3: Attachment Resistance Expressed as a Moment - M (ft -Ibf) from PA 102 and PA 102(A) Testing TILE 1 APPROVED APPLICATION NAILS I 1 nail l 2 nails 1 screw 12 screws) . 1 nail 12 nails 1 1 nail 2 nails I Battens I N/A 1 N/A I N/A 26.80 N/A I N/A I N/A N/A Direct Deck 1 6.20 1 8.40 28.70 I 58.20 21.20 I 25.30 26.90 i 34.90 1. Quik -Drive screws installed in two manufactured holes located 1'/ and 1 from the head of the tile. APPROVED' SCREWS APPROVED FIELD CLIP WITH: Table 4: Attachment Resistance Expressed as a Moment - M (ft-Ibf) from PA 101 Testing Tile I Tile Profile Application Product Control No.: 96- 1030.03 Or a. (ft') Direct Deck Application 0.31 Attachment Resistance Mortar Set I 24.50 Adhesive Set 66.50 Frank Zuloaga Plans Examiner, Product Control Division 7 ":12" or greater APPROVED EAVES CLIP WITH: • 1 10" PROFILE DRAWING ALTUSA "S" CLAY'ROOF TILE DOVE TAIL LOCKS 13 <■• - - 4$ 011u '" • Product Control No.: 96 Fran uloaga Plans Examiner, Product Control Division {� '> !/ ° e /1 NAIL HOLE BIRD STOP PROFILE DRAWING ALTUSA "S" CLAY ROOF TILE ACCESSORIES NAIL HOLE • fY 14 GABLE —RAKE Fran uloaga Plans Examiner, Product Control Division Product Control No.: 96- 1030.03 Or i SYSTEM LI,MMITATIONS Product Control No.: 96- 1030.03 Cr The standard minimum roof pitch for Altusa "S" high profile tile shall comply with Dade County Application Standards PA I IS, PA 119 or PA 120, depending on the method of installation. For nail - on applications, fasteners for mechanical attachment of tiles shall have a head diameter larger than that of the preformedholes in the tile. 3. System installation shall be in compliance with the system specifications outlined in this Product Control Approval. The method of attachment utilized shall provide sufficient attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with Dade County Protocol PA 115 or PA 127. Altusa "S" Tile tile profile has been tested for both wind characteristics and static uplift performance, therefore, attachment calculations fo ..`installation in compliance with PA 115 or PA 127 shall be done as a 'Moment Based System'. For mortar or adhesive set tile applications, a field static uplift test by a Dade County accredited testing agency, in compliance with Dade County Protocol PA 106, shall be performed. For mortar set tile applications, ; /90 hot mopped unc criayment r 1 _ 0 n� - r� � applications be installed perpendicular to the roof pitch unless stated otherwise by the underlayment material manufacturer's published literature. 6 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo for identification in the field. 7. Applications for roofing permits shall include a completed Section!' of the Uniform Building Permit, a copy of Pioneer's current specifications and details, a copy of this Product Control Approval and a copy of the Product Control Approval of any Roofing Component used in the proposed tile application. *Reference shall be made to appropriate data for the required fire rating. S. The applicant shall retain the services of a Dade County certified testing laboratory to maintain quality control in compliance with the South Florida Building Code and related protocols. Samples taken shall be in compliance with Dade County Protocol PA 1 12, Appendix 'A'. w 16 Fran:: Zuloaga Plans Examiner, Product Control Division - t • Altusa Tile, Alrnar (USA), Inc. 6645 Northwest 77th Avenue. Miami Fl 33166 Product Control No.: 96- 1030.03 cr ACCEPTANCE NO.: 96 - 1030.03 APPROVED : February 13, 1997 EXPIRES : February 13. 2000 NOTICE OF tCCEPTANCE STANDARD CONDITIONS I . Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than ei;ht (8) years. 2. Any and all approved products shall be pennanently labeled with the manufacturer's name, city, state, and the following statement: "Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the con installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted , is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process: b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any .ether purposes. 6. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. Ifany portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of This Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer. 8. Failure to comply with any section of tIfIs Acceptance shall be cause for termination and removal of Acceptance. 9. This Acceptance contains pages I through 17. END OF THIS ACCEPTANCE 17 ' rani: a oaga Plans Examiner, Product Control Division Owner's Name: Du Quesne & Associates, Inc. Consulting Engineers Testing Laboratory ON -SITE CONCENTRATED UPUFT LOAD TESTING OF ROOF TILE IN ACCORDANCE WITH METRO-DADE BUILDING CODE COMPLIANCE PROTOCOL PA 106 V /WE CNeRcfi Job Address /b70 Roofing Contracts r dG /9O 'DI Type of Tile: /'T L--(' S 1 Approximate Roof Height: feet Type of Access to Roof: Scaffolds Approximate Square Footage of.-'Roof: ft I Required Testing Forcs 35 Ibs Testing Equipment: / Date Tested `° "-" 2 0 q 7 Du Quesne, P.E. ngineer 24513 Du Quesne & Associates, Inc. E.B. License #0005245 Lab Certification #94- 0318.01 SITE SPECIFIC INFORMATION TEST RESULTS P = PASS, F = FAIL Permit #•/ 4 ']:Date Installed: , ' ^ / 7 Roof Pitch 3 :;.` Z' !/ . Ladder Other SKETCH OF ROOF IN BACK Environmental • Civil • Structural Building Inspection Services UTR N2 12547 Test Location 2 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Uplift Pull Test (P or F) ��r4ss Test Location 26 27 28 29 30 32 33 34;.:, 35;. 36' 37 39 41 42 43 44 45 46 47 48 49 50 Uplift Pull Test P or F) Test Location 51 52 53 54 55 56 57 58 59 60 61 62 63 65 66 67 68 70 71 72 73 74 75 Uplift Pull Test (P or F) IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. Please Note: This form is not valid unless Company logo appears in color (burgundy) 7821 S.W. 24th Street • Suite 104 • Miami, Florida 33155 • Telephone (305) 264 - 1425 • Fax (305) 264 -1426 KETCH OF ROOF JOB SHEET NO OF CALCULATED BY DATE CHECKED BY DATE SCALE NOTES* 4 -. 4. KETCH OF ROOF /070 Ni q.5 /V(, i s e ' SHEET NO �C /�� OF Z CALCULATED BY / l • �--:7 DATE 6-23- 97 CHECKED BY DATE SCALE JOB 3 43 4 it ZP Z/ Z k! 2Z (4 2/ g 3 24 z 9 H.) 4 17 /g 1_ 14 - 1 NOTES' DuQuesne & Associates, Inc. Consulting Engineers Engineering, Testing & Environmental Services Laboratory Compliance Letter The PA 106 test reported in report No. t 2. S 4 7 has been performed in full accordance to the requirements of Dade County, with no deviations. Du Quesn P.E. ne & ociates, Inc. 7821 S.W. 24i Street, Suite #104, Miami, Florida 33155/Telephone (305) 264-1425 Fax (305) 264 -1426