Loading...
1041 NE 94 St (8)Date 8 -28 -96 Job Address T041 N..E. 94 Street Tax Folio ' Legal Description Historically Designated: Yes N.. Owner/Lessee /Tenant John Davies Master Permit # 1- 10 3 ff.,. Owner's Address 1041 N.E. 94 Street ph 758 -•4464 ContractingCoQuality Roofing Contractor, Inc. Address 251 N.W. 99th Street Qualifier Carlos Arocho SS# Phone _ _8.2_ State # R f 0 0 5 A F 27 Municipal # Competes tcy 1! LZgBg ._ - - -• Ins. Cu. __ Architect/Engineer Address Bonding Company Address Mongagor - Adttrt::ra Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECI•IANICAL_IiQQEINSL1'AVINC FENCE SIGN •t WORK DESCRIPTION Tear off 8 sq. section of tile roof to wood deck, tincap 301b. ASTM felt as per building code, mop on with type III asphalt one - layer of 901b. ASTm felt install metal eave drip and valley metal where require and install Flat White Colorthru Tile mortar sew approved -73 Dfie Square Ft. 8 sq. Estimated Cost (value) $ 3 , 0 0 0 • 0 0 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTA IN FINANCING,, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum 01 ali in:a ale! I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I undetsianJ tlitit .;el,arur permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING; and MECIIANICAI.. WORK. •• ;:OWNER'S AFFIDAVIT: 1 certify that all the foregoing information is accurate and that all work will be done in compliancL •.v1 all alrliltealrlc laws regulating con . ction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. APPROVED: Zoning Mechanical c of owner and/or Condo President Date PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Notary as to Owner and/or Condo President My Commission Expires: Building 9 Date Plumbing �1-1 P � j e VERONICA A. GALLI G i ,,, , COMMISSION # CC 362114 ;yN o EXPIRES MAY 9,1998 BONDED THRU S Fr„ ,.\ AT' ,1T ✓ knktninic. C0.. INC. FEES: PERMIT RADON ' C.C.F. ' 1 NOTARY Signature of Contractor or Owner - Builder Date Notary as to Contr tor or Own My Commission Expires: Electrical Engineering MA OU HERNAN MY COMMISSION # CC 324212 EXPIRES: October 10, 1997 Bonded Thru Notary Public Underwdters 5 3 c' 'I•OTAI_ Dill{ tl- S NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: 1 0 41 N . E . 94 Street Miami Shores, Florida 33138 2. Description of improvement: Install section of about 8 squares of Tile roof. 3. Owner(s) name and address: John Davies 1041 N.E. 94 Street Miami Shores, Florida 33138 Interest in property: Owner Name and address of fee simple titleholder: N/A 4. Contractor's name and address: Quality Roofing Contractor, Inc. 251 N.W. 99th Street Miami, Florida 33150 5. Surety:(Payment bond required by owner from contractor, if any) N/A Name and address: Amount of bond $ 00 6. Lender's name and address: N/A 7. Persons within the State of Florida designatealiftwfilintarl8hriootheLdoc by Section 713.13(1)(a)7., Florida Statutes, Name and address: N /A 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: N/A 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a differentiate is specified) X "// 19Ma.w. Signature of Owner 1 Print Owners Name 4' Sworn to and subscribed before me this h e. IJ ' e-S Prepared by: Carlos Arocho .19�� /� Quality Roofing Contractor, Ir Address: 251 N.W. 99th Street Y VERONICA A. GN mi F1 nri d 331 50 Notary Public 49' � o , G COMMISSION # CC 362114 Print Notary's Name x `� EXPIRES MAY 9,1998 �q BONDED THRU 'Fnc ■C ell ANTII' RONIIING CO.. INC. My Commission Expires: ts A" T)F VI ( ° COUNTY OF GAD= �r ' •fa ' : ' • • 1 1 1 . t ^71F'/ r itl! ..is i. c R'u_ capy , f 1. e 0.1 .. fif. :d in I i< 1;Irr on A r .. A ' D' I9 ( ..• 1 . o.•. Off X . .l5o't. id as provided 123.01 -52 2/93 N 0 1 0, Job Address: 1 Qt I 1J . E . 9 U ST Ridge Venting: 0' (Vappllcable) Dcck: Type: l .0OO Thickness: ` KV Underlayment: 30 11 , Pr griA 7 Underlayment Fastener. �` 1 a if v, 5l.... 12" FILL IN AI'PLICAI3LE ROOFING COMPONENTS WIIICII MAKE UP TILE SYSTEM ASSEMBLY. INSERT ANY ADDITIONAL LEADERS INDICATING ADDITIONAL ROOFING COMPONENTS NOT SIIOWN ON THIS PAGE. ( Where Roofing Component not used in Tile Systcm Assembly, fill in with "N /A ". ) Head Lap Dimension: J " (minimum 2' unless otherwise specified 1n the tile system assembly Product Control Appso d) Mortar /Adhesive: Tile: f t \1� CoIo(- ..CLA t Tile Tile Fastener: Edge Metal or Gutter Fastener: I I `1 � f S h�K Y14 7 -1 - 5 Bird Stop: ` : 1 (Uoppncable) �J Edge Metal it or Gutter: �%t, __ V C..y t 2—C.4 r` 1l0 Existing or Proposed Soffit Venting: to DETAIL #1 Job Site Identification: Mortar or Adhesive Set Tile Systems Page - 5 Process No. Job Address: I L I 1 LI Contractor: Q►,■tjAtjOi �� C Dn -� Ridge Height: Eave Height: Roof can Height _id_ feet j (7 feet ) W' feet BUILDING INFORMATION #1 Job Site Identification: Mortar or Adhesive Set Tilc Systems Page - 6 Process No. Insert Building Ridge Height, Eave Height and Roof Mean Height. Also insert applicable information pertaining to the building below. ( See ASCE 7 - 88 Fact Sheet Attached ) Exposurc Catcgory: Classification Category: Ground Level At l lurricancc Occanline?: Y ✓ N Basic Wind Speed at Building Location. 110 mph Building Condition based on % of openings: (See Table 9 ofASCE 7 -88) Job Address: /0 - 1 N C.. ( Pi ST a Contractor: BUILDING INFORMATION #2: Roof Plan with Perimeter and Corner Dimensions Job Site Identification: Mortar or Adhesive Set Tile Systems Page - 7 Process No. Sketch Roof Plan, indicating all dimensions, slopes and any rooftop equipment. Also insert variable labeled "a" which represents perimeter and comer dimensions per Chapter 23 of the South Florida Building Code. (See ASCE 7 -88 Fact Sheet Attached) Job Address: 1 0 L/ 1 , 9 l_1 Sl The undersigned certifies that the Mortar or Adhesive Set Tile System Assembly is in compliance with the plans, specifications, and details submitted by the architect. STATE OF FLORIDA - COUNTY OF DADE // Before me this day personally appeared ert (I05 4(oc -<1-0 who, being first duly sworn, deposes and says that all information submitted herein is true and correct. Sworn to and subscribed before me this (o th day of 19% . My commission expires: MARYLOU HEP,NANDEZ MY COMMISSION N CC 324212 10 1997 Bonded Thru Notary Pubic ender atte Licensed Contractor / Owner Signature Notar #Public State of Florida Contractor: actii:),/ 1c, e J Process No. /2t Mortar or Adhesive Set Tile Systems Page - 8 Job Address: ) Dt-I l 13 • F ' q sr. Contractor: Adhesives (continued): Additional Notes: Note: Application of adhesives shall be in compliance with the Roofing Component Product Control Approval and the minimum requirements set forth in Subsection 3403.5(e)(4)(cc) of the South Florida Building Code. Ventilation System (check one or more of the following): The following information is required to confirm compliance with Subsection 3401.4(e) of the South Florida Building Code. O Ridge: Type ' Size / in2 I Soffit: Type y t/ en 13 Size '/" Y /a. `' in Note: If underlayment is comprised of a self - adhered membrane, both soffit and ridge ventilation systems are required, unless a base sheet is applied as an anchor sheet below the self - adhered underlayment. Note: The Tile System Assembly shall be installed in strict compliance with the application instructions enumerated in the Product Control Approval. A permit shall be issucd for application of the specified Tile System Assembly only. Any change to the specified Tile System Assembly shall require submission of a revised SECTION II with a copy of SECTION I, noting the permit number issued. Mortar or Adhesive Set Tile Systems Page - 4 Process No. Job Address: 104 1 10 F c q ST. Underlayment (continued): Check all of the following which apply to the proposed underlayment for use with the proposed tile system assembly: 'ASTM #30 asphalt saturated felt with: Manufacturer: ❑ ASTM #15 asphalt saturated felt with: Manufacturer: Mineral Surfaced Roll Roofing with: Manufacturer: ❑ Other: Type: Manufacturer: Underlayment Fasteners (if applicable): O 19" overlap ❑ 6" overlap E — 4" overlap O 19" overlap O 6" overlap O 4" overlap O 19" overlap O 6" overlap Eel" overlap Contractor: Check one of the following which apply to the proposed underlayment attachment: Minimum 12 ga. electro- galvanized roofing nail with minimum 32 ga. x 1' / tin cap: Length: t " Manufacturer: ❑ Other: Type: Length: Manufacturer: Mortar or Adhesive Set Tile Systems Page - 3 P ua1STS �Cck 1 5 Spacing (per tile system assembly Product Control Approval): Field: JJ " o.c. Laps: 9 "o.c. 5. Related Accessories: Edge Metal (refer to Section 3408.2 of the South Florida Building Code): Type: Dimensions: ) Gauge or Thickness: .2Ce Finish: e-c LUc._r.: c_r Note: All edge metal shall be nailed on the flange and nailed or clipped at the face in compliance with the provisions set forth in Dade County Protocol PA 111, marked Appendix 'U' in the South Florida Building Code. Adhesives (check one of the following): ❑ Cold Adhesive: Type: Manufacturer: " Flashing Cement: Type: Manufacturer: Process No. Job Address: /WI 11E. &ILI s Project Information (continued): If the proposed undcrlayment is self- adhered, have you complied with the venting requirements of Section 2913.3 (b), (c) and (d) of the South Florida Building Code? yes no Are all related accessories approved for use with this tile system assembly? Tile: Tile Name: Manufacturer: no Are the proposed edge metal attachment fasteners in compliance with the requirements of the South Florida Building Code (minimum 12 ga. annular rinhank, corrossion reisistant nails)? no 4. The Tile System Assembly: The following information is required to confirm compliance with Subsections 3403.5(a) and (c) and Section 3404 of the South Florida Building Code. Tile Material: O Clay V Concrete ❑ Other: Product Control Approval Number: Mortar or Adhesive: -I2 . )L1 Contractor: Check one of the following which apply to the proposed tile securement for use with the proposed tile system assembly: Mortar or Adhesive Set Tile Systems Page - 2 LB' Mortar: Manufacturer: Mixing Ratio: ❑ Adhesive: Type: Manufacturer: Process No. 3• Tile Fasteners (for first three courses if roof pitch exceeds 5 ":12" and is less than or equal to 7 ":12 "): Check one of the following which apply to the proposed tile fasteners (for the first three courses) for use with the proposed tile system assembly: ❑ Minimum 12 ga. galvanized roofing nail: ❑ Other: Type: Length: Ly'N /A Underlayment: Length: Note: All tiles shall be installed in compliance with the provisions set forth in the tile system assembly manufacturer's Product Control Approval and the minimum requirements set forth in Subsections 3403.5(c) and 3404.2 of the South Florida Building Code. Tile fasteners in the first three courses (if applicible) shall be of sufficient length to penetrate the sheathing a minimum of 1" or through the sheathing thickness a minimum of / ", whichever is less. The following information is required to confirm compliance with Section 3403.5(b) of the South Florida Building Code. APPENDIX 'E' METRO -DADE UNIFORM BUILDING PERMIT SECTION II MORTAR OR ADHESIVE SET TILE SYSTEMS Job Address: I () t_/ i . F 9 L/ S 1. General Contractor: The information provided in this Section is required to confirm Product Control Approval of the proposed tile system assembly; confirm compliance with the wind load requirements of Chapter 23 of the South Florida Building Code (SFBC); and confirm compliance with Sections 3403.5 and 3404 of the South Florida Building Code. 2. Documentation The following documents are required for submission with the Uniform Building Permit application: Two (2) copies of the proposed tile system assembly's and associated roofing component's Product Control Approval(s). One (1) copy of the tile system assembly and/or roofing component(s) manufacturer's published application instructions and literature. 0> All documents attached herein, filled out and completed in full. 3. Project Information Check one of the following: ❑ New Construction a Re -Roof No)e: Mortar or adhesive set tile systems are not acceptable as recover applications. 12301-158 Mortar or Adhesive Set Tile Systems Page - 1 Is the deck solid sheathed? . cle 'yes' or 'no') yes no Deck Type (check one of the following): ❑ Nominal ' /2" Plywood (for re -roof only) ❑ Nominal ' / Plywood wood Plank 1 X (v " ❑ Other (fill in) Roof Pitch (fill in): 62 " : 12" Note: Mortar or adhesive set tile systems shall not be installed at a pitch greater than 7%2 ":12 ". Mortar or adhesive set tile applied at a pitch greater than 5 ":12" and less than or equal to 7 ":12" shall have the first thrcc courses of tile nailed with not Tess than one nail per tile. As an alternate, the first three courses of tile may be applied in mortar over a single layer of minimum 12 ga. wire mesh with square openings of not less than 3 / e " which is mechanically attached to the sheathing with not less than one nail per 2 ff. Circle 'yes' or 'no' for each of the following: Have you attached two copies of the tile system manufacturer's Product Control A. royal for the proposed tile system? no Have you attached a copy of the tile system assembly and/or roofing component(s) manufacturer's published, application instructions and other literature no Is the proposed underlayment approved for use with this tile system assembly? no . METRP-DADE METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING PRODUCT CONTROL NOTICE OF ACCEPTANCE Metro Roof Tile, Inc. 11350 N.W. South River Drive Miami, FL 33178 Your application for Product Approval of: Fiat Cement Tile under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Redland Technologies, TheCenter forApplied Engineering, Inc., and Testwell Craig Laboratories & Consultants, Inc. has been recommended for acceptance by the Building Code Compliance office to be used in Dade County, Florida under the specific conditions set forth on pages 2 et. seq. and the Standard Conditions on page 3. This approval shall not be valid after the expiration date stated below. The Office of Code Compliance reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The applicant shall re- evaluate this product or material should any ammendments to the South Florida Building Code be enacted affecting this product or material. The Building Code Compliance Office reserves the the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.:94- 1222.14 Expires:06 /15/98 THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. Approved:06 /15/95 -l BUILDING CODE COMPLIANCE OFFICE SUITE 1603 METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375 -2908 PRODUCT CONTROL SECTION (305) 375 -2902 FAX (305) 372 -6339 Product Control Supervisor tlGSanger, Director Building Code Compliance Dept. Metropolitan Dade County Applicant: Metro Roof Tile, Inc. 200 Story Road Lake Wales, FL 33859 PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING SYSTEM APPROVAL Category: Prepared Roofing Sub - Category: Flat Tile Type: Nail- on/Mortar Set/Adhesive Set Sub -Type: Concrete System Description, Metro Roof Tile, Inc., located in Medley, Florida, manufacturers clay roof tile for nail -on, mortar set or adhesive set applications. This Product Control Approval relates to Metro Roof Tile's "Concrete Flat" flat tile profile. Refer to appropriate Product Control Approvals for other tile profiles. The Metro Roof Tile "Concrete Flat" tile profile is available in a variety of colors and has snatching trim pieces used for rake hip, ridge hip, and valley terminations. These accessories are manufactured for all profiles and form a part of this Product Control Approval. The Metro Roof Tile "Concrete Flat" roof tile has been tested in compliance with the South Florida Building Code requirements for concrete, nail -on, mortar set or adhesive set tile applications. See the "Profile Drawing" section in this Approval for the Metro Roof Tile "Concrete Flat" profile drawing. The Metro Roof Tile "Concrete Flat" profile has been tested for both wind characteristics and static uplift performance, therefore, any consideration for installation shall be done as a 'Moment Based System'. Data for attachment calculations is noted in Tables 1 through 4 of this Approval. Contact: Fernando Arias Metro Roof Tile, Inc. 11501 Northwest 117th Way Miami, FL 33178 (305) 558 -6712 2 Raul Rodriguez Product Control No.: Approval Date: Expiration Date: 94 -1 222.14 JUN 1 5 1995 JUN 1 5 1998 Test Product Product Dimensions Specifications Description Metro Roof Tile 1= 16" PA 112 Flat, interlocking, high pressure Concrete Flat w = 10" extruded, concrete roof tile equipped 11/4" thick with two nail holes. For direct deck or battened nail -on , mortar or adhesive set applications. Trim Pieces TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT I = varies w = varies varying thickness PA 112 Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. 3 Raul Rodriguez Product Control No.: 94- 1222.14 Product 1130 Felt 1143 Coated Base Sheet Mineral Surface Cap Sheet Lenzingtex -ZB l40 Underlayment Rainproof 1l Ice and Water Shield Mopping Asphalt Flashing Cement TRADE NAMES OF PRODUCTS MANUFACTURED OTHERS Dimensions N/A N/A N/A 59" x 164' roll 22 Ibs /roll 30" x 75' roll 36" x 75' roll or 60" x 75' roll 36" x 75' roll N/A N/A Test Specifications ASTM D 226 type 11 ASTM D 2626 ASTM D 249 PA 104 PA 104 PA 103 ASTM D 312 type III or IV ASTM D 4586 4 Raul Rodriguez Product Control No.: 94- I222.14 Product Description Saturated organic felt to be used as a nailed anchor street. Saturated and coated organic base sheet for single or double ply underlayrnent. Mineral surfaced asphalt roll roofing for use as a top ply in a double ply underlayment system. Single ply, nail -on underlayment. Single ply, nail -on underlayment with 2" self - adhering top edge. Self- adhering underlayment for use as a top ply in a two ply underlayment system with approved 1130 or /143 as the base layer. Asphalt for bonding a mineral surface cap to a mech. attached base sheet in a double ply underlayment system. Cut back, asphalt based, asbestos free, fiber reinforced, trowel grade cement for repair and flashing applications. "Manufacturer generic generic generic Lenzing Performance, Inc. with current PCA Protect -O -Wrap, Inc. with current PCA W.R. Grace Co. with current PCA generic generic Test Product Product Dimensions Specifications Description Manufacturer Asphalt Primer N/A ASTM D 41 Cut back, asphalt generic • • based coating used to facilitate bonding of dissimilar materials. Rcefina Nails Tin Caps Wood Battens Tile Nails Tile Screws min. 12 . with 3 / 8 " head min. 32 ga. min. 1'4" o.d. max. 2" o.d. PA lla Appendix E min. 8d x 2' /s" or min. IOd x 3" #8 x 2Y2" long 0.335" head dia. 0.131" shank dia. 0.175" screw thread diameter PA 114 Appendix E vertical Wood Preservers Salt pressure treated niin. 1" x 4" Institute LP - 2 or decay resistant horizontal lumber battens min. 1" x 4" for use with vertical battens or min. I" x 2" for use alone PA 114 Appendix E PA 114 Appendix E 5 Raul Rodriguez Product Control No.: 94- 1222.14 Annular ring. shank. hot dipped, electro or mechanically gals. roofing nails for use in underlayment attachment. Corrosion resistant circular disc for use in underlayment attachment Corrosion resistant, .screw or smooth shank nails. Corrosion resistant, coated, square drive, galvanized, coarse thread wood screws generic generic generic generic generic Roof Tile Mortar N/A PA 123 Prepared mortar mix Bermuda Roof ( "TileTiteT "' ") designed for mortar Company, Inc. set roof tile with current PCA applications. Roof Tile Mortar N/A I'A 123 Prepared mortar mix Quikrete Constructio ( "Quikrete® Roof designed for mortar Products Tile Mortar #1140") set roof tile with current PCA applications. Test Product Product Dimensions Specifications Description Man u fact nrer Roof Tile Mortar N/A PA 123 Prepared mortar mix W.R. Bonsai Co. ( "BONSAL® Roof designed for mortar with current PCA Tile Mortar Mix ") set roof tile applications. Roof Tile Adhesive N/A PA 110 Adhesive designed Polyloam Products, (Polypro® A1-1160) for use in roof tile Inc. applications. with current PCA Hurricane Clip & 0.425 PA 114 Corrosion resistant Fasteners min. I A" width Appendix E bronze, aluminum, min. 0.060" thick stainless steel, galvanized steel or Clip Fasteners plastic attachment min. 8d x 11/4" clips for supplemental tile attachment. Clips are installed with corrosion resistant roofing nails compatible with the clip. Valley Flashing Drip Edge min. 26 ga. min. 16" width min. 26 ga. min. 2" face flange m in. 2" deck flange ASTM A 525 Galvanized steel valley flashing PA 1 1 1 Galvanized steel drip edge 6 7 72 Raul Rodriguez Product Control No.: 94 -1 x22 ,14 generic generic generic Test Agency Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Testwell Craig Laboratories & Consultants, Inc. TEST REPORTS Test identifier 7161 -03 Appendix 111 7161 -03 Appendix III 94 -084 94 -060A 7161 -03 Appendix 11 Report Dated Aug. 1, 1994 P0631 -0I PO402 Project No. 307025 Test #MDC -77 Lab #: EA -22 Tech: G. Suarez 7 Raul Rodriguez Product Control No.: 94- 1222,14 Test Name /Report Static Uplift Testing PA 102 Static Uplift Testing PA IO2(A) Static Uplift Testing PA 101 (Mortar Set) Static Uplift Testing PA 101 (Adhesive Set) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Set) Withdrawal Resistance Testing of smooth vs. screw shank nails Wind Driven Rain PA 100 Physical Properties PA 112 Da Dec. 1991 Dec. 1991 May 1994 March, 1994 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Oct. 1994 July 1994 SYSTEMS (CONTINUED) Deck Type: Wood, Non - insulated Deck Description: New construction I9 /„" or greater plywood or wood plank. SYSTEM D: Mortar or Adhesive Set Application Product Control No.: 94 1222.14 Slope Range: 2 ":12" to 7 ":12" Note: System D is only acceptable in this slope range. For slopes in excess of 7 ":12 ", refer to System C. Underlay men t: Roofing Tile: Comments: Install underlayment system in compliance with Dade County Application Standard PA 120. (See System Limitation H5.) Install tile in compliance with Dade County Application Standard PA 120. (See "Data for Attachment Calculations" included in this Approval.) 1. For re -roof applications, 1S /,," plywood is an acceptable substrate. 11 Raul Rodriguez SYSTEM LIMITATIONS Product Control No.: 94- 1222,14 1 The standard minimum roof pitch for Metro Roof Tile's "Concrete Flat" flat profile tile shall comply with Dade County Application Standards PA 118, PA 119 or PA 120, depending on the method of installation. 2. For nail -on applications, fasteners for mechanical attachment of tiles shall have a head diameter larger than that of the preformed holes in the tile. 3. System installation shall be in compliance with the system specifications outlined in this Product Control Approval. The method of attachment utilized shall provide suflicient attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with Dade County Protocol PA 115 or PA 127. The Metro Roof Tile "Concrete Flat" tile profile has been tested for both wind characteristics and static uplift performance, therefore, attachment calculations for installation in compliance with PA 115 or PA 127 shall be done as a 'Moment Based System' 4. For mortar or adhesive set tile applications, a field static uplift test by a Dade County accredited testing agency, in compliance with Dade County Protocol PA 106, shall be performed. 5. For mortar set tile applications, 30/90 hot mopped underlayment applications nay be installed perpendicular to the roof pitch unless stated otherwise by the underlayment material manufacturer's published literature. 6 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo for identification in the field. 7. Applications for roofing permits shall include a completed Section 11 of the Uniform Building Permit, a copy of Metro Roof Tile's current specifications and details, a copy of this Product Control Approval and a copy of the Product Control Approval of any Roofing Component used in the proposed tile application. Reference shall be made to appropriate data for the required lire rating. 8. The applicant shall retain the services of a Dade County certified testing laboratory to maintain quality control in compliance with the South Florida Building Code and related protocols. Samples taken shall be in compliance with Dade County Protocol PA 1 12, Appendix 'A'. 9. Any amendments to these provisions shall be in compliance with Sections 203 and 204 of the South Florida Building Code. 12 Raul Rodriguez Table 3: Attachment Resistance Expressed as a Moment - M, (ft -Ibf) for Nail -On Systems Tile Profile Tile Application Approved Nails Approved Screws Approved Field Clip With: Approved Eave Clip With: 1 nail 2 nails 1 screw 2 screws 1 nail 2 nails 1 nail 2 nails Metro Roof Tile Concrete Flat Battens 4.90 7.40 5.40 9.10 24.20 34.80 22.10 32.20 Direct Deck 9.80 18.80 25.30 41.30 24.30 35.50 19.00 31.90 Table 2: Restoring Moments due to Gravity - M (ft -Ibf) Tile Profile 3 ":12" or less 4 ":12" 5 ":12" 6 ":12" 7 ":12" or greater Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Metro Roof Tile Concrete Flat 6.53 6.97 6.43 6.86 6.29 6.71 6.14 6.54 5.97 N/A Table 4: Attachment Resistance Expressed as a Moment - M, (ft-lbf) for Mortar and Adhesive Set Systems Tile Profile Tile Application Attachment Resistance Metro Roof Tile Concrete Flat Mortar Set 39.00 Adhesive Set 118.90 Table 1: Aerodynamic Multipliers - X (ft') Tile X (ft') a. (ft') Profile Batten Application Direct Deck Application Metro Roof Tile Concrete Flat 0.27 0.29 DATA FOR ATTACHMENT CALCULATIONS Product Control No.: 94 - 122LJ4 Raul Rodriguez PROFILE DRAWINGS METRO ROOF TILE CEMENT FLAT TILE Raul Rodriguez Product Control No.: 94- 1222.14 METRO DADE This approval supersedes all previous approvals. NOTICE OF ACCEPTANCE; STANDARD CONDITIONS 15 METI1OPOLITAN DADE COUNTY, FLORIDA METflO•DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE DEPARTMENT SUITE 1603 ME1110 -DADE FLAOLER f3UILDINCI 110 WEST FLAOLER STREET MIAMI, FLORIDA 33130.1503 (305) 375 -2001 FAX (305) 376 -2900 1. Extensions of Acceptance may be considered after a new application has been filed and the supporting data, test reports no older than ten (10) years, have been re-evaluated. All reports of re- testing shall bear the seal, signature and r to of an engineer registered in the State of Florida. 2. Any revision or change in the materials, use, or manufacture of the product or process shall automatically be cause for termination, unless prior approval is granted for ,evi,S - ons or change. 3. Any unsatisfactory performance of this product or process or a chrange in Code provisions shall be grounds for re- evaluation. 4. This acceptance shall not be used as an endorsement of any product for sales or advertising purposes. 5. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 6. Product approval drawings, where required for permit applications, shall be pro. i, °d to the applicant by the manufacturer or his distributors unless otherwise noted in the Notice of Acc( ;)tai.cc. The prints need not be re- sealed by an engineer. 7. Failure to comply with the Standard Conditions shall be cause for termination of the Appr. val. Raul Rodriguez Product Control Supervisor METRO ROOF TILE INC. 11501 N.W. 117 WAY MEDLEY FL. 33178 (305) 558 -6712 • INSTALLATION INSTRUCTION FOR " FLAT " TILE 1. CHECK ROOF PROPERLY THE FIRST RUN CAN OVERHANG BETI.iEEN 1/2 AND 3/4 INCHES OVER THE EDGE. ALL OTHER HORIZONTAL LINES SHOULD BE MARKED AT 13.0 INCHES (3" OVERLAP). a) THE MORTAR HAS TO BE FRESH AND SHOULD BE USED WITHIN ONE HOUR AFTER BEING MADE. IN DADE COUNTY A PREMIX BAG HAS TO BE USED FOR MORTAR. THE MORTAR IS APPLIED VERTICALLY WHERE THE TWO CAVITIES OF THE TILE ARE LOCATED. A FULL TROWEL No. 10 WILL BE SUFFICIENT FOR THE JOB. IT WILL TAKE BETWEEN 5 AND 6 POUNDS OF MORTAR ENOUGH AMOUNT OF MORTAR SHOULD BE APPLIED TO FILL THE CAVITIES. AS THE TILE IS BEING PLACED ON THE ROOF, IT SHOULD SQUEEZE SOME MORTAR OUT. b) THE TILE SHOULD NOT BE WALKED ON AFTER IT HAS BEEN SET IN PLACE, UP TO AT LEAST 5 DAYS AFTER ITS INITIAL PLACEMENT. c) AFTER THE 5 DAYS THE ROOF CAN BE CLEANED AND CHECKED FOR ANY LOOSE TILES THAT WERE NOT IN STALLED PROPERLY. IF ANY ARE TO BE FOUND, ANY CEMENT GLUE SUCH AS RT 600 CAN BE APPLIED TO FIX THE LOOSE TILES. 2).THE TILES ARE BEING MANUFACTURED IN MIAMI 11501 N.W. 117 WAY MEDLEY FL. 33178 Test Location Uplift Pull Test (P or F) Test Location Uplift Pull Test (P or F) Test Location Uplift Pull Test (P or F) 1 '�•A. 7 26 4 __= 51 _ cS 12 2 27 52 3 28 53 4 29 54 5 30 55 6 31 56 7 32 57 8 33 58 9 34 59 10 35 60 11 36 37 _51 62 12 13 38 63 14 39 64 15 40 65 16 41 17 42 _5_§ 67 18 43 68 19 44 69 20 45 70 21 46 71 22 47 72 23 48 73 24 49 74 25 50 75 Du Quesne & Associates, Inc. Consulting Engineers Testing Laboratory ON -SITE CONCENTRATED UPUFT LOAD TESTING OF ROOF TILE IN ACCORDANCE WITH METRO -DADE BUILDING CODE COMPLIANCE PROTOCOL PA 106 Owner's Name: .TOHN $,ROk Att4llt- .j AV I S Permit #• 413 ti 3 Job Address _ I D • Roofing Contractor u _.( Ty F( t Of Type of Tile: 41 IS ET Date Installed 7 / 9 `9 ? Approximate Roof Height t Z - feet Roof Pitch 3 ' (Z•- Type of Access to Roof: Scaffolds )L Ladder _ Other Approximate Square Footage of Roof 2200 ft 2 Required Testing Force: 35 lbs. Testing Equipment: Chatillion DFIS 100 Date Tested , • 2 1 • aq IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. THIS :ia1]:f. UB ia1li' BY: rge Du Quesne, P. it Engineer . #24513 Du Quesne & Associates, Inc. E.B. License #0005245 Lab Certification #94- 0318.01 SITE SPECIFIC INFORMATION TEST RESULTS P = PASS, F = FAIL SKETCH OF ROOF IN BACK Environmental • Civil • Structural Building Inspection Services THIS PA 106 TEST HAS BEEN PERFORMED IN FULL ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTY, WITH NO DEVIATIONS. Please Note: This form is not valid unless Company logo appears in color (burgundy) 7815 S.W. 24th Street • Suite 109 • Miami, Florida 33155 • Telephone (305) 264 -1425 • Fax (305) 264 -1426 UTR 15922 $KETCH OF ROOF JOB SHEET NO OF CALCULATED BY DATE CHECKED BY DATE SCALE NOTES. KETCH OF ROOF JOB 1 od 5T., NA • 5.+,40 SHEET NO. . Z- •zz • 99 CALCULATED BY CHECKED BY SCALE DATE DATE ■_■■ ■ Mill ■NNW • ■■ ■ ■NII E1111111 en•rr+lE ■■■■■■■■■rn__ __ ■■■■■ • ME Mill =III. • ■■ ■ ■uiAr■ VILUNII■ ■ ■ ■ ■• ■1uI . ■_■■■il1■1l ■FIN ■ ■■■ O MI Will _ AIIIIIPILIMINErleME •1■ IMENEMBIE I MI L. v, i■".rii is ■■■■ ■ • 11=111111011111111121M1 IfMnIrell ►MEIA •■ • ■ E N I ■ MEM mum ENi__••ii i FAIIMIEJILWASINIIIIPIIIIIM 01111111k111 IIIEMIPIPIIIIIIN mantainnrdimarm IN INIMPIRMEMI MUM amnion ■■ ■111 ■lr ■■ ■ ■..i■ ��■ mom 1111 11111111 EMI ME UM 10 ■■■■ NM 111 ■ ■■■ ■■ ■■■■■ E NOTES: MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regula- tions of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Address � Registered Architect and /or Engineer_____r_ r ------ - .: — Name A + Name and address of licensed contractor `.-- /72W1 _ is Location and legal description of lot to be built on: Lot_ Block_ Subdivision 1. • � —'-t-s , Street and Number where work is to be done _____J V � L4e* `� d s . • State work to be done and purpose of building (by floors) Disapproved (Signed) Date_ ---------- - - - - -- — _and for no other purpose. New Building —__ ____ Remodeling___ ___ Addition_________ — ___ Repairs �' ____ No. of Stories__ - To be constructed of Kind of foundation_ — ________ —_ Roof Covering_ ___ 41:2* — Estimated Total cost of improvements $___� _ _,Amount of Permit $ Zone cubage required_ Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub- contractors employed by him in the work to be performed under this permit: and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work e� performed under this permit, as are licensed by Miami Shores Village. V � s Remarks (Signed) %✓ STATE OF FLORIDA, COUNTY OF DADE. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally appeared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated areszue. i Permit No .2 Z A Date_ '' / Read, Sworn to and Subscribed before me. Building Inspector My Commission Expires Date_ —__ // 19 `-�c No� /9Ere 9 /r� . Notary Public, State of Florida PLANNING BOARD DATE Chairman Member Member Member Member Member — Council Approved Date Disapproved _Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and/or workmanship. Disapproved (Signed) MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby wade for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at budding during progress of the work. Date —I L : 1 ,19 ® Owner's Name and Address . � � T : .�. A 1!6 fH- �? .S._ _. No / Street._...N — J'l Registered Architect and /or Engineer � ..... ............... .......... . _....... Name and address of licensed contractor. .14. r.E _ 4.. ° e: ' Ems' -Qcp t; G Q Location and legal description of lot to be built on: 307 C- E L t Z A E (. f „57- Lot Block Subdivision �y Street and Number where work is to be done / _ K _ ` State work to be done and purpos of building (by floors) VI- and ._ for no other purpose. New Building Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation , Roof Covering Estimated Total cost of improvements $ 3 Za Amount of Permit &........ 4 Zone cubage required Plan Cubage Distance to next nearest building Size of Building Lot :Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer of labor under the 'Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for in ection on the site of the work such public notice or notices as arc required by the Act. The undersigned agrees to employ only such sub tractors, work to be ormed under this permit, as are licensed by Miami Shores Village. Remarks Building Inspccto STATE OF FLORIDA, COUNTY OF DADE. Ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared _.. and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stattgd are _._ true. o Permit No.. 9 3 . d Date r ( r 7` Read, Sworn to and Subscribed before me. Notary Public, State of Florida My Commission Expires to me well known, ANNING BOARD DATE Chairman Member Member Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. Building Insp MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. ff ZZ Date /f e'� 3/ ,19 G O Owner's Name and Address ._..._M 0 /.. 1 .. 23 No._J0 / 1 Street._.. E 7 V • c r Registered Architect and /or Engineer _ /�� Name and address of licensed contractor_. _ f~ , "1 4 rm 1 5 `I 0 O F/WC _ Location and legal description of lot to be built on: sh , 'P r Lot Block Subdivision ,4 FRB rf A /l D /Ti 0 a`r ro l`1 /A Street and Number where work is to be done /a S 1 ' /Y E 9 'q 5 1— -� State work to be done and purpose of building (by floors) / 7-i° g �O d !C t / Q; a i and for no other purpose. New Building Remodeling Addition t/ Repairs No. of Stories To be constructed of Kind of foundation Roof Covering 7 Estimated Total cost of improvements $._.. 5 Amount of Permit $ Zone cubage required plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Pennanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub- contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Remarks (Signed) eiC) l '& STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No t/c Date 5 ~ )1 r LP Disapproved (Signed) .. Read, Sworn to and Subscribed before me. Notary Public, State of Florida tor My Commission Expires PLANNING BOARD DATE Chairman Member Member Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re-inspection fee of 51.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and/or workmanship. / \\ SWITCH OUTLETS LIGHT OUTLETS PLUG RECE'P'T'S FIXTURES NO. LAMPS REFRIO. OUTLET IRON OUTLET RANGE OUTLET RANGE CONN. WATER HEATER W. HEAT. CONN. A H ATER STRIP HEATER e ` TOTAL CONT T LIS 7 7 // y // 7 o!� /y CHECK I ENT. SW. DIST. CAS. SERVICE TEMP. SERVICE PERM. MOTORS 0.1 HP MOTORS 1.5 HP N EON TRANS. RADIO TOTAL CONTR. LIST CHECK 1 Permit No MIAMI SHORES VILLAGE ELECTRICAL INSPECTION DEPARTMENT APPLICATION FOR ELECTRICAL PERMIT Owner's Name and Address ld'rg Remodeling Addition Date Porrs— T r tr' '' Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of work. No 1 0 1 7 4 ! Street ,ll 74 Z-°C- :i ( Registered Architect and /or Engineer t fi- ✓ i/ Employing Electrician's Name - i� ` GF,G No O /7" ! Street dV s V , � Q Location and Legal Description Lot Block Subdivision V Street and umber where work is to be performed —No Street �� .rk to be performed and purpose of building (By Floors) Repairs No. of Stories ervice Overhead Underground Type of Installation— Conduit Amount of Permit $ STATE OF FLORIDA, } COUNTY OP DADE. u .4/e.{- 3 2 ?* ✓' Size Feeders Conduit Main Sw Tubing e/ B.X.L SS. Before me, the undersigned authority, a notary public, duly authorized appeared 0A Amps .!�..Main Fuses Amps 0 A Metal Moulding /,1 (Signed) Electrical Inspector. The undersigned applicant for this building permit does hereby certify that he understands and accepts his •bligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florid, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub -con ctors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the ork such public notice or notices as are required by the Act. The undersigned agrees to employ only such sub - contractors, on . • ..• pert• •• nder this permit, as are licensed by Miami Shores Village. (Signed) � �M to administer oaths and take acknowledgments, personally to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, and he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. My Commission Expires Notary Public, State of Florida NOTE: A re- inspection fee of $1.00 will be made when such re- inspection is made necessary by improper notice for inspecti or faulty materials and /or workmanship. Owner/Lessee/Tenant Roxane Davis PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 2 -19 -99 JobAddress 1041 N.E. 94 Street Tax Folio ) Legal Description Historically Designated: Yes No Master Permit # 6 7 �/ 3 Owner's Address 1041 N.E. 94 Street Miami Shores Phone 758 -4464 ContractingCoQuality Roofing Contractor, Inc. Address 13800 N.W. 1st Avenue Qualifier Carlos Arocho SS# Phone 7S1-0382 State # RC 0 0 5 8 6 2 7 Municipal # Competency # 1 7 R S q Ins. Co. Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION Tear off old roof to wood deck, tin cap 301b. ASTM felt as per code install eave drip metals, mop on with type III asphalt one layer of 901b. ASTM felt, install SprilshSUay Fwkc- colorthru tile with adhesive foam setting. Square Ft. 3 4 s q. Tile 2 s q. Flat Estimated Cost (value) $ 13,0000.00 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. 649 2-19-71 Signature f owner and/or Condo President Date Notary as to 0 'er and/or My Conunission Expires: FEES: PERMIT 1(9 RADON 02 - IC Signature of Contractor or Owner- Builder Notary as to Contrac or 0 My Commission Expires: C.C.F. 7 - '° NOTARY - - O APPROVED: Zoning Building SPI 6 47q Electrical Mechanical Plumbing Engineering Date - / . -" Date BOND / 6k9 TOTAL DUE WS NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property. and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. I. Legal description of property and street address: 2. Description of improvement: Reroof to a new Tile and Flat roof. 3. Owner(s) name and address: Roxane Davis Interest in property: ' Owner' Name and address of fee simple titleholder: N/A 4. Contractors name and address: Quality Roofing Contractor, Inc . 13800 N.W. 1st Avenue Miami, Florida 33168 5. Surety:(Payment bond required by owner from contractor, if any) Name and address: N/A Amount of bond $ 00 6. Lender's name and address: N/A 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: N/A 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: N/A 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording, unless a different date Is specified) J ikijc-co S&pruture o1 Owner n Print Owners Name 1nyarie S. Oa th e.S Sworn to and subscribed before me this 1 C\ day of 1.eJ Notary Public 1)10.A. Print Notary's Name My Commission- Expires: STATE OF FLORIDA, COUNTY OF DADE 1 H RE7y CERTIFY rla. ibis is a 1 o is 1 in f.5is o=fi 1041 N.E. 94 Street Miami Shores, Florida 33138 1041 N.E. 94 Street Miami Shores, Florida 33138 MARYLOU HERNANO i a 1 i , MY COMMISSION # CC 880474 WIRES: October 10, 2001 _ "4=° B onded Mu Notary Public Undeneettem py of fho d. of A D 1 -nd ()Picini Seal. ER1t, of Circuit and County Cowls r \ 1 9 99R 109269 1999 MAR 03 09:33 Prepare Qu Addres dby: Carlos Arocho ality Roofing Contractor s:13800 N.W. 1st AvenuE Florida 33168 12301.52 2193 Contractor's Name: (uati -,( R 3 3 l or m r r , t . Job Address: 10u . E. ( Iy s \ f ROOF CATEGORY ,�,/ '(Low Slope Application) ❑ (Nail -On Tile) 11G(Lortar- Adhesive Set Tile) . ❑ (Asphalt/Fiberglass Shingles) ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other) ROOF TYPE ❑ New Roof 5Re- roofing ❑ Recovering ❑ Repair ❑ Maintenance Flat Roof Area (ft2) . s Sloped Roof Area (ft ,W S e Total (ft') 3 Master Permit No. Exposure category (per ASE 7 -88): L Building Classification category (per ASCE 7 -88 table 1): O f fv)P I4fr 4— s 4 DETAIL vLily(N r DETAIL 1 & 2 ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed) t0 Ft. n V Ft. Deck type: t.JOc A \Kt. ATTACHMENT Fastener Type: i rLi (`ing nct IS SPACING 1 Field: D .C. Perimeter: D • L Corner:ia r ROOF PLAN 123.01.78 8168 Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. Page -1 Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. Ridge Ventilation? PJ 4Yr- Al E.4N }LEICRT Deck type: I,3 pp Insulation: 0 l 1 Fastener type & spacing: 11" ROOF SLOPS Cap Sheet: f] b Roof overing: Drip edge: C� Ior �hrL, ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals (Pmaxl: .3 x a, (AerodynamioMultiplier): MA � ) - (Pmax2: 1O3:)1 x'ab (Aerod Multiplier) :3 1S ) (Pinax3: Iv fl x (Aerodynaa Multiplier): )1.1 .1J ) TILE CALCULATIONS M :S •3S = M 11,D1,v PCA: (de M ,S•3 =M :° (p.){O PCA: 1.04) -SO - M 5--3S _= M: 2AL1D PCA: ,)V PRODUCT CONTROL NOTICE OF ACCEPTANCE . Altusa Tile, Almar (USA), Inc. • 6645 Northwest 77th Avenue Miarni, FL 33166 Your application for Product Approval of •.1 /rasa Tile 1Vai / -On, Mortar Set or Adhesive Set One Piece "S" Tile Roofing Tile under Chapter 3 of the Metropolitan Dade County Code governing the use of Alternate Materials and Construction, and completely described in the plans, spccitications and calculations as submitted by: Types of !icdlond Technologies, The Center for Applied Engineering, Inc. has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions set forth on pages 2 -16 and the standard conditions on page 17. This approval shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Building Code Compjiance Office may revoke, modify, or suspend the use of such product or material immediately. Tne Building Code Compliance Office. reserves the right to revolve this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the S. th Florida Building. Code. The expense of such testing will be incurred by the manufacturer. ACCEPTANCE NO.: 96- 1030.03 Renews 94-0914.0 EXPIRES: 02/13/00 THIS IS THE COVERSHEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County 8. ding Code Compliance Office and approved by the Building Code Committee to be use. in ..de County. F . .., under the conditions set forth above. APPROVED:02 /13/97 METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE SUITE 1603 METRO DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 INTERNET: mdcc01@shadow.net PRODUCT CONTROL SECTION (305) 375 -2902 FAX (305) 372 -6339 Raul Rodriguez Product Control Division Supervisor Charles Danger, P.E. Director Building Code Compliance Dept. Metropolitan Dade County Applicant: Altusa Tile Alfareria del Turbio, S.A. Barquisimeto, Venezuela Category: Sus- Cateaorv: Type: Sub -Tyne: Product Control No.: 96- 1030.03 PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING SYSTEM APPROVAL Prepared Rooting Tile Nail-on/Mortar Set Adhesive Set Clay System Description Alfareria del Turbio, S.A. (Altusa), located in Barquisimeto, Venezuela, manufacturers clay roof tile for nail -on, mortar set or adhesive set applications. All tile is manufactured from natural Venezuelan clays. This Product Control Approval relates to A Itusa's "Altura S" tile profile. Refer to appropriate Product Control Approvals for other tile profiles. The "Altusa S" tile profile is available in a variety of natural clay colors and has matching trim pieces used for rake hip, ridge hip, an valley terminations. These accessories are manufactured for all profiles and form a part of this Product Control Approval. Optional rubber or clay eave closures are also available. Altusa roof tiles have been tested in compliance with the South Florida Building Code requirements for clay, nail -on, mortar set or adhesive set tile applications. The minimum roof slope for the "Altusa S" nail -on tiles shall be 2 ":12 ". See the "Profile Drawing" section in this approval for the "Altusa S" profile drawing. The "Altusa S" profile has been tested for both wind characteristics and static uplift performance, therefore, any consideration for installation shall be done as a 'Moment Based System'. Data for attachment calculations is noted in Tables 1 through 4 of this Approval. Almar (USA), Inc., located in Miami, Florida, is the sole approved importer under contract for selling and distributing Altusa products in the South Floyjda jurisdiction. Contact: Carlos J. Fernandez General Manager Altusa Tile, Almar (USA), Inc. 6645 Northwest 77th Avenue Miami, FL 33166 (305) 471 -5830 Frank Zuioaga Plans Examiner, Produci Control Division Product Control No Approval Date: Expiration Date: .: 96- 1030.03 February 13 1997 February 13, 2000 Product Control No.: 96- 1030.03 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Test Product Product Dimensions S eciiications Description • Altusa One Piece "S" ' 1 = IS" PA 112 Til <v = 1 " high profile clay roof tile for direct • deck or battened nail -on, mortar or ��= thick adhesive set applications. Head -lap min. Exposure max. 15 Trim Pieces I = varies w = varies PA 112 Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Frank 7_uloaga Plans Examiner, Product Control Division SYSTEMS (CONTINUED) Deck Type: .Wood, Non - insulated Deck Description: New construction ' or greater plywood or wood plank. SYSTEM 1): Mortar or Adhesive Set Application Slope Range: . : , 2" to 7":12" Lndcrlavrncnt: Roofing Tile: Comments: Product Control No.: 96- 1030.03 Note: Svstent I) is only acceptable in this slope range. For slopes in excess of 7 ":12 ", refer to System C. Install underlavment system in compliance with Dade County Application Standard PA 120. (Sec System Limitation g5.) Install tile in compliance with Dade County Application Standard PA 120. (See "Data for Attachment Calculations" included in this Approval.) 1. For re -roof applications, 15 /3:" plywood is an acceptable substrate. Frank Zuloaga Pans Examiner 1 -rodu_t Control Divisic:: f• i IAltusa 'S' Tile Tile Profile AItusa 'S' Tile Tile Profile I I DATA FOR ATTACHMENT CALCULATIONS Table 1: Aerodynamic Multipliers - X (ft') Batten Application 0.29 Table 2: •Restoring Moments due to Gravity - M (ft-Ibf) from PA 102 Testing 3 ":1 I 4•:12" or less 5 ":12" Battens I Direct Battens Direct I Battens Direct Deck Deck Deck 1 4.47 i 5.35 4.40 5.27 I 4.31 5.16 Battens I 4.20 6 ":12" Direct Deck 5.0r Battens 4.08 7 ":12" or greater Direct Deck N/A Table 3: Attachment Resistance Expressed as a Moment - M (ft-lbf) from PA 102 and PA 102(A) Testing Tile Profile I Altusa 'S' Tile TILE APPLICATION APPROVED 1 APPROVEDI NAILS SCREWS I 1 nail 2 nails I 1 screw Battens I N/A I N/A I N/A 2 screws APPROVED FIELD CLIP WITH: 1 nail 12 nails 26.80 I N/A I N/A Direct Deck I 5.20 I 8.40 I 28.70 I 58.20 APPROVED EAVES CLIP WITH: 1 nail N/A 26.90 2 nails N/A 34.90 21.20 I 25.30 1. Quik -Drive screws installed in two manufactured holes located 1 and 1 from the head of the tile. Table 4:' Attachment Resistance Expressed as a Moment - M (ft -Ibf) from PA 101 Testing i I Altusa 'S' Tile Tile Profile Tile Application i Attachment -•.- Resistance Morar Set Adhesive Set 24.50 66.50 Direct Deck Application 0.31 Frank T-utoaga Plans Examiner, Product Control Divi:;ion Product Control No.: 96- 1030.03 ,t1 T 1 17 17 10" PROFILE DRAWING ALTUSA "S" CLAY ROOF TILE / 4 "4/ • 1 DOVE TAIL LOCKS i 3 ..,,agumun, -.4(-"‘ " 4/42 .e 4> 4 .. .o .7 7 \ 7 \ Fran uloaga Plans Examiner, Produc: Control Division • Product Control No.: 96-1030.03 NAIL HOLE BIRD STOP PROFILE DRAWING ALTUSA "S" CLAY ROOF TILE ACCESSORIES NAIL - €OLE ZA /./ ; \.‘ / Product Control No.: 96- 1030.03 GABLE-RAKE Fran, uloaga Plans Examiner, Exarr,iner, Produc: Control Division 1 .—, , 4 1 7Thj ..--1 ,X7t--c \\-- \ \—: \--< ,, , ..\ , , r \ 4 N' \ A \ \ % 1 —•■ to- 0 3- / \ •r- 2 7 PLC PROFILE DRAWING APPROVED SCREW 15 Frank Zuloaga Plans Examiner, Prod.:z: Control Division Product Control No.: 96- 1030.03 SYSTEM LIA'MLTATIONS Product Control No.: 96- 1030.03 I. The standard minimum roof pitch for Altusa "S" high profile tile shall comply with Dade County Application Standards PA 1 1 S, PA 119 or PA 120, dependimz on the method of installation. 2. For nail -on applications, fasteners for mechanical attachment of tiles shall have a head diameter larger than that of the preformed holes in the tile. 3. System installation shall be in compliance with the system specifications outlined in this Product Control Approval. The method of attachment utilized'1:ail provide ; ►fficicnt attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with Dade County Protocol PA 115 or PA 127. Altusa "S" Tilt, tile profile has been tested for both wind characteristics and static uplift performance., therefore, attachment calculations for installation in compliance with PA 115 or PA 127 shall be done as a 'Moment Based System'. For mortar or adhesive set tile applications, a field static uplift test by a Dade County accredited testing agency, in compliance with Dade County Protocol PA 106, shall be performed. For mortar sct tilt applications, 30'90 hot mopped underlayin. nt applications may be installed perpendicular to the roof pitch unless stated otherwise by the underlayment material manufacturer's published literature. 6 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo for identification in the field. 7. Applications for roofing permits shall include a completed Section!! of the Uniform Building Permit, a copy of Pioneer's current specifications and details, a copy of this Product Control Approval and a copy of the Product Control Approval of any Roofing, Component used'in the proposed tile application. Reference shall be made to appropriate data for the required fire rating. S. The applicant shall retain the services of a Dade County certified testing laboratory to maintain quality control in compliance with the South Florida Building Code and related protocols. Samples taken shall be in compliance with Dade County Protocol PA I ! 2, Appendix 'A'. 16 j Fran u oa ' P :tnc Ex: :nnirrer. Produ•. Control Division Altusa Tile, Alntar (USA), Inc. 6645 Northwest 77th Avenue. Miami Fl 33166 Product Control No.: 96- 1030.03 ACCEPTANCE NO.: 96 - 1030.03 APPROVED : February 13, 1997 EXPIRES : February 13, 2000 NOTICE OF ACCEPTANCE STANDARD CONDITIONS i . Renewal of this Acceptance (approval) shall he considered after a renewal application has been filed and the original submitted documentation. including test supporting data. engineering documents. are no older :han ci_h: (a) !ears. • ` Any and all approved products .;h :Sl! be permanently labeled with the nhanut::cttrr eT s name, city, state, and :he following statement: "Dade County Product Control Approved', or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; h) The product is no longer the sane product (identical) as the one originall),a,pprovecl; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted , is no longer practicing the engineering profession. �. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process: b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration date maybe displayed in advertising literature.. I?any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. .A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer. S. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Acceptance contains pages 1 through 17. END OF THIS ACCEPTANCE ) r J Fran,; u oaga "'--- Plans Examiner, Product Control Division PRODUCT CONTROL NOTICE GS Roofing Products Company, Inc. 5525 MacAuthur Boulevard, Suite 900 Irving, Texas 75038 • Acceptance No.: 97- 0520.01 Revises No. 95-0502.04 Expires: 06/19/00 OF ACCEPTANCE METROPOLITAN DADE COUNT;Y,,FLORID METRO - DADE FLAGLEft.P4ILDI■ BUILDING CODE COMPLIANCE:OFFIC.E METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 16034: :` MIAMI, FLORIDA 33130 - 1563 (305) 375-2901 FAX .(305) 375 -2908 • PRODUCT CONTROL DIVISION :i (305) 375 - 2902 :. FAX (305) 372 -6339 Your application for Product Approval of: • GS Roofing Products Modified Bitumen Roof Systems Over Wood Decks under Chapter 8 of the Metropolitan Dade Counry Code governing the use of Alternate Materials and Types Construction, and completely described in the plans, specifications and calculations as submitted by: Factory• Mutual Research Corporation and Underwriters Laboratories, Inc. has been recommended for acceptance by the Building Code Compliance Department to be used in Dade County, Florida under the specific conditions set forth on pages 2 through 31 and the standard conditions set forth on page 32. • The approval shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time for a jobsite or manufacturer's plant for, quality control testing. If this product or material fails to perform in the approved manner, the Building Code Compliance Office may revoke, modify or suspend the use of such product or material immediately. The applicant shall re- evaluate this product or material should any amendments to the South Florida Building Code be enacted affecting this product or material. The Building Code Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by th man ac r. Raul Rodr Product Control Supervisor THIS IS THE COVERSHEET. SEE ADDITIONAL PACES FOR SPECIFIC AND GENERAL CONDITIONS Approved: 06/19/97 BUILDING CODE COMMITTEE Internet mail address: postmaster ©buildingcodeonline.com ar es Danger, P.E. Director Building Code Compliance Dept. Metropolitan Dade County This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. Homepage: http : / /www.buildingcodeonline.com tit Applicant: GS Roofing Products Company, Inc. (MB) 5525 MacArthur Blvd. Suite 900 Irving, TX 75038 Catesorv: Membrane Roofing System Sub - Category: Built -up Roofing Tvpe: Modified Bitumen Sub -Tvpe: SBS /APP ROOFING SYSTEM APPROVAL System Description Product Control No.: 97- 0520.01 Product Control No.: 97-0520.01 Approval Date: June 19, 1997 Expiration Date: June 19. 2000 GS Roofing Products Company, Inc. manufactures and markets nationally a complete line of residential and commercial BUR and modified bitumen products. GS Roofing Products Company, Inc. markets these products through local distribution in the South Florida jurisdiction. GS Roofing products and systems are the result of years of manufacturing experience and product development and have been proven by years of experience in the construction field. GS offers a variety of approved insulated and non - insulated roofing systems. For detailed system constructions, refer to the following publications: "Commercial Roof System Specification Manual ". GS products and systems have been tested in compliance with all provisions of the South Florida Building Code as well as Underwriters Laboratories, Inc., and Factory Mutual Research Corporation for fire and wind uplift resistance. GS provides technical service and warranty information through regional offices. For the South Florida Metro -Dade area, call 1- 800 - 777 -2563. Contact: Pat Neuhaus Commercial District Manager 2900 Bird St. Charleston Heights, SC 29405 (803) 744-7451 ran uloaga-Plans mine , uct Control Div. Insulation Types Fibrous glass Perlite Fiberboard Rockwool Polyisocyanurate Polyisocyanurate Composite Board Maximum Design Pressures Material Design Pressure Wood -45.0 psf Maximum Fire Classification Material Classification Wood Class A Note: Fire classifications and maximum design pressures do not reference all assemblies over deck types. Review system listings for design pressures and the Underwriters Laboratories Rooting Materials Directory ' or other approved testing agency listing directory for Fire Classifications. 3 Product Control No.: ^7- 0520.01 • Fran uloaga -Plans Exami ct Control Div. Wood Deck System Limitations: A red rosin sheet shall be installed on all wood plank decks to eliminate asphalt seepage and bonding of base sheet w wood plank deck. Red rosin sheet may also be installed on plywood decks as an option. 2 Pre - assembled 'Cap Nail' shall not be used for base sheet attachment. 3 When All Weather Empire base sheet is installed as the base sheet, a ply sheet of ASTtN1 D 4601 type 11 (type G2) must be applied in approved mopping asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq prior to installation of membrane. 29 uloaga -Plans Examen Product Control No.: 97-0520.01 uct Control Div. GENERAL LIMtITATIONS Product Control No.: 97-0520.01 I- All asphalt shall comply with ASTM D 312, type III or IV requirements and approved by applicant. Fire ratings are determined by a combination of slope, deck type and assembly. Refer to the current Underwriters Laboratories Roofing Materials Directory or other fire testing data listed in the testing file. Fire ratings shall be in strict compliance with Sections 3401.5 and 3401.6 of the South Florida Building Code. 3 Maximum slope range varies for each system. Consult the current Underwriters Laboratories Roofing Materials Directory and manufacturer's specifications for compliance with design criteria for each project. 4 An overlay and/or recovery board is required on all applications over closed cell foam insulations when the base sheet is fully mopped in hot asphalt. 5 All work shall be performed by a contractor licensed to do roofing work in Metro -Dade County. Contractor shall be familiar with the details and specifications published by the manufacturer and the requirements of the South Florida Building Code. 6 The submission of system specifications and details shall accompany the Section 11 Building Code Permit. This information is available in the publications listed in the 'System Description' of this Product Control Approval. The submission of these documents, as well as the proper application and installation of all materials shall be the sole responsibility of the contractor. 7 Perimeter and corner areas shall comply with the elevated design pressures of these roof areas, as calculated in compliance with Chapter 23 of the South Florida Building Code. Anchor or base sheet fastening patterns and/or insulation attachment densities shall be increased in compliance with the provisions set forth in Metro -Dade County Roofing Application Standard PA 117 to meet these elevated design pressures. 8 All attachment and sizing of perimeter nailers, metal profile and/or flashing termination designs shall conform to Metro -Dade County Roofing Application Standard PA l 1 I and the wind load requirements of Chapter 23 of the South Florida Building Code. 9 Flashings shall be installed according to the manufacturer's standard details and may be applied in cold application adhesive, approved asphalt or may be applied in conjunction with an approved torch applied modified bitumen membrane. Specific details, approved by the manufacturer, shall be submitted with the Section II Permit Application. All details shall comply with the provisions of the South Florida Building Code. 10 Fastener spacing for anchor or base sheet attachment is based on a Minimum Characteristic Resistance Force (F') as determined through field testing in compliance with Metro -Dade County Protocol PA 105 or PA 105(A). If F', as tested, is less than that listed in the System Limitations, a professional engineer may 'submit revised fastener spacings utilizing F', taken from a Metro -Dade County Protocol PA 105 or PA 105(A) test report, and the provisions set forth in Metro -Dade County Roofing Application Standard PA 117. 11 Fastener density for insulation attachment is based on a Minimum Characteristic Resistance Force (F') as determined through field testing in compliance with Metro -Dade County Protocol PA 105. Iff', as tested, is less than 275 lbf., insulation attachment shall not be acceptable. l2 Asphalt moppings shall be applied with approved asphalt and shall be in compliance with the equiviscous temperature (EVT) methods of asphalt determination. Asphalt containers or bulk tickets shall indicate an EVT, finished blowing temperature (FBT) and flash point. Asphalt types and temperature ranges shall be in compliance with Subsection 3403.4(A)(3) of the South Florida Building Code. 13 Insulation may be applied in multiple layers. The first layer shall be attached in compliance with the Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq., or mechanically attached using the fastening pattern of the top layer. Refer to manufacturer's literature and/or the NRCA Roofing and Waterproofing Manual for correct application procedures of insulation panels in approved asphalt or adhesive, which shall comply with the provisions of M PA 117. - ;::: • ° .. - .. ' tion Standard 30 gaga -Plans *ntt-Priaduct Control Div. Product Control No.: 97 - 0520.01 14 All standard insulation panels sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 15 In re -covery applications, prior to.the application, all existing roof surfaces used as a bonding substrate shall be tested in compliance with Metro -Dade County Protocol PA • 124 for uplift resistance. Test pressures shall be calculated in compliance with the wind load requirements of Chapter 23 of the South Florida Building Code for the roof in question. 16 In re- roofing applications, moisture content in an existing roof must be in compliance with Subsection 3401.10(m), (n) of the South Florida Building Code. 17 Roof goods shall be stored on end and on a clean, flat and dry surface. 18 If required, any Factory Mutual Approved vapor barrier in conjunction with proprietary or approved adhesives may be used prior to the application of the insulation layer. 19 Consult current Underwriters Laboratories Directory for the appropriate coating for each roofing assembly to obtain the required fire rating. The assembly shall be installed in strict compliance with Subsection 3401.5 and 3401.6 of the South Florida Building Code for maximum fire classification. 31 uloaga -Plans xam , ' ..uct Control Div. CS Roofing Products Company, Inc. 5525 MacArthur Blvd., Suite 900 Irving, Texas 75038 ACCEPTANCE NO.: 97- 0520.01 APPROVED: June 19. 1997 EXPIRES: June 19, 2000 NOTICE OF ACCEPTANCE STANDARD CONDITIONS 1 Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. ' Any and all approved products shall be permanently labeled With the manufacturer's name, city, state, and the following statement: "Metro -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3 Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4 Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5 Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6 The Notice of Acceptance number preceded by the words Metro -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7 A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer. 8 Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9 This Acceptance contains pages 1 through 32. END OF THIS ACCE 32 Product Control No.: 97- 0520.01 Product Control Div. Maximum Design Pressure: -45 psf Maximum Fire Classification: Class 'A'; see General Limitation #2. Maximum Slope: 1:12; see General Limitation #3. Specification No.: GMS 2 -3, FRP 2 -3, GTS 2 -3, FRBC 2 -3 27 Product Control No.: 97- 0520.01 Membrane Type: SBS MODIFIED Deck Type 1: Wood, Non- insulated Deck Description: 19 / 12 " or greater plywood or wood plank decks System Type E: Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of GS Glas Base, GS Flex -I Glas Base. Flex -I Glas FR Base or GS Poly SMS base mechanically fastened as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with approved roofing nails and tin caps 9" o.c. in the lap and two rows staggered in the center of the sheet 12" o.c. Ply Sheet: (Optional) One ply of GS Glas Base, GS Flex -1 -Glas Base, Flex- I -Glas FR Base, GS PoIySMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 Ibs./sq.. _ Membrane: One ply of Flintlastic GMS, Flintlastic Premium GMS, Flintlastic FR -P, Flintlastic Premium FR -P, Flintlastic FR -PG or Flintlastic FR Cap adhered to base or ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs. /sq. or Flintlastic GTS torch adhered to base or ply sheet Surfacing: (Optional) Install one of the following: 1. 400 lb./sq. gravel or 300 lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 Ibisq.. 2. Karnak 97 or APOC 212 Fibrated Aluminum at an application rate of 1 % gal. /sq.. Frank Zuloaga -Plans Examiner, P o3uct Control Div. ROOFING SYSTEMS (TGFU)-- Continued Membrane: One layer "FlinUastic GTA (.3 sq or -1 s ), GTS' (modified bitumen), heat ?used or "Fllntlastic CMS'. hot mopped. Surfacing: APOC "No. 212 Fibratad'Alunsinum', at 1.1/2 gal. 100 sq /ft. 0°ck: NC inctinai 3/4 Vapor Retarder (Optional): Type GZ "Glasbase base .sheet or UL Classified vapor retarder. Insulation Optional): One or more layers or combination of the following: Utragard Prernie, polytsocyanurate, partite. glass fiber or wood fiber insulation. Base Sheet: One layer of Type G2 "Gtasbase' base sheet. Membrane: One layer of "Fltnttastic STA (modified bitumen), heat fused. Surfacing: Karnak "No. 97 Ilbrated Aluminum ", at 1 -1/2 gal, per 100 sq/it. Deck C -15/32 lnctine: 3/2 Insulation (optional): Schuller International "UttraGard Premier, po(yisocyanurate, wood fiberboard. partite, fiberglass. esocyanurate, any thickness. . Base Sheet: One or more plies of "Glasbase ", hot mopped or mechanically • fastened.' ' • . • Membrane: One p(y of "Flintlastic FR" (modified bitumen), hot mopped in place. Dacia 'RC Indite: 1/2 Insulation: Po(yisocyonurate, glass fiber, pertite, wood fiber, hot mopped or mechanically fastened, any thickness. Base Sheet: Type 62, mechanically fastened or hot mopped. Membrane: "Ftintlasdc GTA or STA ", heat fused. Surfacing: Henry Co. 'Henry 520 Aluminum', applied at 1 -1/2 gatJsq. Deck: NC.. Iodine: 1/4 Insulation" (0ptional):•Glass• fiber, pertite or wood fiber board. Ply Sheets ype G2. m:chanically'fastened. •. Membranes Flintlastic STA ", "GTA ", "GTA Blade Diamond' or 'GTA White Diamond ". heat fused. Surfacing: ICamak Chemical Corp. "Karnak No. 97', 19al/sq. Deck NC Inclines 1 Insulations Potyisocyanurata glass fiber. pertite. wood fiber, mechanically fastened or adhered with hot roofing sphalt, any thickness. Base Sheet: Type G2, mechanically fastened or adhered with hot roofing asphalt Membrane: "F1tntlastic GMS ", "Gt4S Premium ", adhered with hot roofing asphalt Surfacing: Karnak 'Chemical Corp. " Kamak No. 97 Fibrated Aluminum Asphalt Roof Coating ", 2 -1/2 gal /sq. Deck: C- 15/32' Iodine: 1 'AU joints blocked with 2x4's. Insulation: Glass fiber, pertite. 3/4 in. min. joints in insulation must be offset 6 in. from joints in deck, mechanically fastened. Base Sheet Type G2, mechanically fastened or adhered with hot roofing asphalt Membrane: "Flintlastic 6MS ", adhered with hot roofing asphalt. Surfacing: Karnak Chemical Corp. 'Karnak No. 97 iibrated Aluminum Asphalt Roof Coating', 2 -1/2 gal/sq. .. Deck: NC Incline: 1/2 Insulations: Potyisocyanurate, glass fiber, partite, wood fiber, mechanically fattened or adhered with hot roofing asphalt, any thickness. Base Sheets Type 62, mechanically fastened or adhered with hot roofing asphalt. Membrane: "Flintlastic STA" . "GTA ", 'GTA Black Diamond" or "GTA White Diamond', heat fused in place. Surfacing: Karnak Chemical Corp. "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating ", 3 ga(/sq. Dec - NC•-• • ... Indioe: 1 Insulation (0 tfona()31'rlitty lass.fitierk olyurethane, isocyanurate, phenolic combinationiisocyanurate/ partite, pTOy rethane /pe ' orwood ' fiber, any thickness. hot mopped or nailed Membrane: "Flinttastic STA ". "GTA', "GTA Black Diamond ", "Ftintlastic GTA White Diamond', "GMS ". "GMS -5M ", 'CMS Double Coverage' or "GMS Premium ", heat PJsed or hot mopped in place. • Surfacing: Grundy Industries, Inc.'al MB Aluminum Roof Coating" at 1:2 • 0. oo V k• C 15/32 • Incline: 1/4 ' • ' Insulation (Optional): Any thickness poly co yanurote, glass fiber or pertite, mechanically fastened, joints in insulation must be offset 6 in. from joints in deck. &ace Sheet: Type G2 base /ply sheet, mechanically fastened' or hot mopped. Ply Sheets Type G2 base /ply sheet, mechanically fastened or hot mopped. . Membrane: "Flintlastic STA ;'GTA White Diamond" or "GTA Black Diamond'. Surfacing: Grundy's "al MB Aluminum Roof Coating' at 1 to 2 gal/sq. ' Uecle NC Incline: 1/2 • Insulation (optional): Potyisocyanurate, glass fiber, pertite, wood fiber, any combination, any thickness, mechanically fastened. • . ROOFING SYSTEN.S (TGFU)- •Continued Base Sheet Type G2, 'Flex- I -G'as FR" or "Flintlastic FR Base', mechanics fastened or adhered with hot roofing asphalt. Membrane; 'flintlastic FR•P", "Flinttastic Premium FR. "Flintlastic. FR/PG' or "Flintl:stic FR Cap', adhered with hot wofi asphalt 12. Deck C•15/32' Incline: 1/2 • .`ii ' *AU joints in deck blocked 'rith 2s4's. • ‘Z.• • Insulation (Optional): P•ilyisocyanurate, glass fiber. pettite.. combination, any thickness mechanically fastened. Base Sheet: Type G -2. mechanically fastened or adhered with hyt r asphalt, Membrane: "Flinttasac FR -P", "Flintlastc Premium FR -r.or "flip FR/PG", adhered with hot :oofing asphalt: 4. eck�(NC Incliner 1/2 7 1nsul -(Optional): ;VS. any thickness. coveted with 1J2.ih:, pertite or wood fiber. met hanically fastened. • :. Base Sheet Type G2, men hanically fastened or adhered with hot asphalt. •0 Membrane: "Ftintlastic F.P. l' "FlintLestic Premium FR or'Ri FR/PG', adhered with hoc roofing asphalt. 14. Deck, NC incline. 1/2 ' •; .. Insulation:. Polyisocyatrurate, . glass fiber, pertite, wood -fibe - . . combination, any thickt.ess.'mechanically fastened. .•• • • ,•'•:.': " • Base Sheet Type G2 es 'Flex- i•gtas , adhered •witruhot : 4 - 1 :t ; ,.. , ''' , .:: Ply Sheet SMS Base Sheet °. adhered with hot roofihg;asp Membrane: GMS , adhered with hot roofing asphalt .:_,:; ry,. ;•#,. Surfacing: Karnak Chemical Corp. " Kamak No. 97 fib:ated -.A t. Asphalt Roof Coating ", at 2 -1/2 ga/sq. • i.:2.. r:' r • 15. Deck NC Incline: 1/4 i. Insulation (Optional': Polyisocyanurate, glass fiber, periite,•wo any combination. any thickness, mechanically fastened or adhe hot'roofing.asphalt :.v. Base Sheet: Type G2 or• "flex -i -glass mechanically fastened•o with hot roofing aspralt - • Pty Sheet (Optional): Type G2 or "Flex- i- glas', mechanioUy _ i adhered with hot roofing asphalt Membrane: "Flintla :tic GMS ", "GMS Premium', adhered with`hoa ; s c':. asphalt. • •s-•: ••: Surfacing: Asphalt Products Oil Corp. "APOC -400 Sunbrite? ;3 gain ._ 16. Deck: C- 15/ IncUne 1/4 :1 7 ;' ;• ;. Insulation: Glass fiber, pertite, 1 in. min. joints in insulato t:::' offset 6 in. from j :int:5 in deck, mechanically fastened...' i `• Base Sheet Type G2 or las "..mechanically fastened Ply Sheet . (Optice lel): Type G2 or "Flex- i- gtas'. mechanically. . adhered ivith hot roofing asphalt- .. Yin, tS Premium', adhered wit asphalt Surfacing: Asphalt Products Oil Corp. "APOC-400 Sunbrit&.., ' 7. Deck: NC Inane: 1/2 . ?: Insulation (Op tonal): Polyisocyanurate pertite,' glass fi fiber, any thickness, mechanically fastened or hot mopped., Base Sheet One or more layers of Type 62 or "Pita- i- glas1 fastened or hot mopped in place. • ttea Ply Sheet (Optional): One or'more layers or Types 61, G2'or mechanically futened or hot mopped in place- • '• Membrane: "F.intlastic GVA', "GTA Blade Diamond', "GTA W or "STA ", heat fused. ; Surfacing: Karnak Chemical Co. "No. 97', applied at,1• 18. Deep NC lndiner 1/4 "..' Insulation Optional): PerUte, glass fiber, mechanically.;, mopped in pace, 2 in. max thidmess. • • • .,:. e, Base Sheet: One or more layers of Type 62 "Flex -l- stened or not mopped in place. LOOK FOR MARK ON PRODUCT ; Ply t One or mom layers of Types 61;4, or "Poly Ste!. Base Sheet',, mFeirratmcally- fastened or tiol;mo, Membrane: "GTA', "Gl'A Black Diamond', 'GTA Whifd'Dfarii: heat fused . • - . • ,,;. ` ' Surfacing: APOC No. 212 Aluminum Coating, •applied';a 19. Deck: C -15/:2 Indlner 1/2 • lnsulatimo Glass fiber or pertite. min 1 in. thick mesh or hot ni: pped in place. •• 'ease Shea: Type G2, "=lax- I -Glas' or "Flex -I -Gras FR P. . fastened or hot mopped in place ,, . - Membrat,e: "Flintlastic FR -P", 'Fliottastic Premium FR1P,'"o ; ;- ; •ry f FR/PG', tot mopped in place.: ' • . . :..- e F ,,, -1 :'•"..:- ' 20. DCCk NC " .Incline^ 2 ., ...T. Insulation (Optional): Pertite, glass fiber, polyureth phenol""" combination isocyaeurate /pertite. potyureth • ,,. '?:'� ",; Fiber, a ry. thickness. mechanically fastened or hot mdp • ' J' . • Base • 'Flex -I -Gras FR Base', Type. G2 car "Fle:e=T-GL ;v fastened of hot mopped in place. • ' e '' Nembr FR• 21. k Ins ole or h Base I Mem De ck C I ntu l: c om b' m utt B ase r oofi n B ase w D ec ith Ba N@rr 7 Declt: ;m fast aas adh ` Ply "ilr • adl gat Ni • Co