WS-11-238Inspection Number: INSP - 156295 Permit Number: WS -2 -11 -238 Scheduled Inspection Date: February 24, 2011 Inspector: Bruhn, Norman Owner: NIEMAN, MAURINE Job Address: 1030 NE 95 Street Miami Shores, FL Project: <NONE> Contractor: FLORIDA HOME IMPROVEMENT Building Department Comments REPLACE 1 IMPACT DOOR PassetW_ ) Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. February 23, 2011 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspector Comments For Inspections please call: (305)762 -4949 Permit Type: Windows /Shutters Inspection Type: Final Work Classification: Door Replacement Phone Number Parcel Number 1132050120070 Phone: (954)792 -4415 Page 16 of 17 jflij L;vv7A. BUILDING PERMIT APPLICATION FBC 2004 Permit Type (circle): Owner's Address Owner's Name (Fee Simple Titleholder) City Srr'Q.C)State Tenant/Lessee Name Miami Shores Village Building Department (0050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795:2204 Fax: (305) 756.8972 Roofng Uj,t,y tr .e, 95 51 Zip 3 ,5138 103o &)�- GS sT Job Address (where the work is being done) City Miami Shores Village County Miami -Dade FOLIO /PARCEL# • CD 1204' 001 0 Is Building Historically Designated YES NO Contractor's Company Name Contractor's Address AO 0 ••") 7 City kit4..0 OO CO State Q»nlifierName (.0t,pp.AD tb)(i €,t Phone# `sk-Oct �St4 State Certificate or Registration No. Ce...N cou9a Certificate of Competency No. Architect/Engineer's Name (if applicable) &V1 Oeoto z•irrko Phone # Value of Work For this Permit $ 4®5o Square / Linear Footage Of Work: Type of Work: Describe Work: ['Addition #mot Submittal Fee Permit Fee $ /I Phone # DAlteration ['New 1/Repair/Replace ❑ Demolition CCF $ Notary $ raining/Education Fee $ Scanning $ Radon $ DPBR $ Bond $ Code Enforcement $ Double Fee $ zip 3'5138 7L at FEB 1 4 2011 BY: _ooee oao �e_m___ee Permit No. iQ S 11 Master Permit No. p e_.rn Phone # hone # 4012, 'i,I S Y � . N5L,xco (, 0 CO /CC Technology Fee $ Zoning $ Structural Review. $ Total Fee Now Due $ See Reverse side Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Own . or Agent The foregoing instrument was acknowledged before me this r 0 day of % , 201 , by MO( l kit Q l.d. , who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: APPLICATION APPROVED BY: (Revised 07/10/07) .d . c)) —/6-7z NOTARY PUBLIC: Zip Application is hereby made to obtain a permit to do a work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT:" Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will no be approved and a reinspection fee will be charged Contractor The foregoing instrument was acknowledged before me this l (o day of 4 1"—e. ,20d , by(&)Ci l 1 .) (u.4 who is personally known to me or who has produced as identification and who did take an oath. P(1 s `P O c23 Print: G¢' 00 01. 0 ecP, Is ei ose My Commission Ex it �. o '� . .- * * ** *** ** * * * *** * * * * * * * * * ** xa :n,y `_ fe la�� Zoning Plans Examiner Engineer NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. STATE OF FLORIDA: COUNTY OF MIAMI -DADE: TAX FOLIO NO. L( -•001O THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 111111 CFN 2011R0106346 OR pI, 27589 F's 1528 (ips) RECORDED 02/16/2011 11:39:37 HARVEY RUUIN, CLERK OF COURT MIAi1I -LADE COUWTYr FLORIDA LAST PAGE Space above reserved for use of recording office 1. Legal descri tion of 4o • erty and stree address: fyi1<'h 4d d 4O Q.1.1? la . Sires I 2. Description of improvement: i7f)err 3. Owner(s) name and address: t' L) 14 Interest in property: t j i^�d Name and address of fee simple titleholder: 4. Contractor's name, address and phone number. 5. Surety: (Payment bond required by owner from contractor, if any) Florida Home- Unpreveme Associates 4070 SW 30th Ave v Name, address and phone number: Ihlt LORI Amount of bond $ I HEREBY CER77FY that &is is s true copy of ft 6. Lender's name and address: 7. Persons within the State of Florida designated by 0 Section 713.13(1)(a)7., Florida Statutes, Name, address and phone number 8. In addition to himself, Owners designates the follow 713.13(1)(b), Florida Statutes. Name, address and phone number 9. Expiration date of this Notice of Commencement: (the = • iration date is 1 year from the date of recording unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF CO i ENCEMENT. Signature( of f yjer(s) or Ow Print Name Ate.e.. Title/Office .'i t , STATE OF FLORIDA COUNTY OF MIAMI -DADE The f regoing instrument was acknowledged before me this By P I �) (1 n e N�ke u tin ❑ Individually, or ❑ as for 1 1 Wersonally known, or ❑ produced the following type of identification: Signature of Notary Public: Print Name: (SEAL) VERIFICATION PURSUANT TO SECTION 92.525. FLORIDA STATUTES Under penalties of perjury, I declare that I have read the foregoing and that the facts ;: -ted in it are true, to the best of my knowledge and belief. Authorizeiti Officer/Director /Partner/Manager Prepared By Print Name Title/Office 0 day of s)'s Authorized Officer/Director /Partner/Manag By C . A96 J (,1 )•r 1- (l a53)2 li I MMIMMMMIMMIIMMMMVAMMINI imrAmmomm A ... IFS .f T %�....Mi Sl > IEE ...� ��.....1-.:�-..or __r .. w..v<<:n SI..al MLLUMw..a EMM n � A� - w wl.■D , ... ... .-�� ._..n.... , :imwm .. r MUMMEMPIMMUMMIMMMUMMEMM ?MI. A . X ...ar3.■c .. . Mra MOE' ...E.M.MM.. . /.. /..... m i■ _ umm . . ...E......E.a. ... .... NM ..2....................r. �f 1................... -m ...•.... r �.. . :........... ■..a ... a�u _.. T� 1 ............•_. .w .10..�....�............,.....E a. ..../ .............w'7.... a r' r w .. .. ..... mmaililt.... a.... , .d• ..w • ..l .. . - c....�...... . . r.. , .. y...........r■•J+�..MMII..■•i , IN 1E A�..rA..ltrrof.ar...wa►�a� rlmvAms mum . i n . / iumi[f-r: i; tl■C• •.l..• ••..►11.: 1 . to r. Y4 mmimmi l�.ltrlt.....' .-TiAammiallumw4`, . miag c N.....a.....�1.....w ..w► � >• .� rk '� a ••••........... .w■�.irr�'A` $ . . 3. im..E... s ...... momm a�,� m∎ ■r�.►r `' 9 ..ana��.ur,�ail■�iimwora sAi law tr ' , ; fal.. , r immin II rw • • E-- r i 1 a ••••ES •.. lt ] ► _ (& :••r . 0.. m ......Miii....>•% =��1- �.� II . A 1- bFb R IWiV•mum.a� matigr i�f/ih . E �i�i"�i 1 . 11MMO M......afaat -MWM MOW . is .....f'�...........a�rr .. .. a ir /i r t) ® .�.............EEE •• E • ..I • — .. a7......... . ■ � ..�..7 ................. . �MR •••••••• ••E. E f�'+.a�.. ...... ..' • . a....�..,..... w�rarT...�. . '..l■1.... rfi rAMM .�w...a■MMMMMiri..wf. E• 'ari v; 4 •...•.. /...�.....•. . .E► • .....M ... . .�. ........MMIM .rAM.•f.aM........w...M .a... -- 4k' ..o.u..• ........ ..... i amn A..V m'...... .....• .•. mmainummommmummommummmum _ - 1....a1•.. IMEMEm W 2LL &Luu kaat.. ■.1..1■. • ... : w o rr......:a� ...E !!!!Migalliktiliiiiii=1:11i../.E.'... wil Mm.11••.!•..m.. //..J /.//./ ..i. ..�T arMi�M....I>•....MMMII... �... �'... //N ik r— dAl &�ni /*aP w.�l•M. l•.t•. I1/ %Lt N!Lri I I 1 f 1 1 1 i 1 I a 1 : i m L - BLDG DEPT FEB 1 4 201 I SUBJECT TO COMPLIANCE WITH ALL FEDERAL STATE AND COUNTY RULES AND REGULATIONS I�•I BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Eurotech Industries, Inc. 250 NE 32 Street Fort Lauderdale, FL 33334 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). • This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or .material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as describedherein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Aluminum Outswing Entrance Door -LMT APPROVAL DOCUMENT: Drawing No W04 -01, titled "Aluminum Outswing Entrance Door", sheets 1 . through 5 of 5, dated 01/15/04 and last revised on June 02, 2009, prepared by AL- Farooq Corporation, signed and sealed by Arshad Vigor, P.E., bearing the Miami Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact . Limitations: 1. Single orr double doors may be mulled with approved clipped mullion or sidelites or transom (under separate approvals), lower design rating shall apply and such installation to be reviewed & approved by AHJ. LABELING: Each unit shall bear a permanent label withthe manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building•code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of,NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade Comity, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews & revises NOA No. 08- 0507.10 consists of this page 1 and evidence pages E-1, as well as approval document mentioned above. • The submitted documentation was reviewed by Ishaq L Chanda, P.E. MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 www.miamidade.gov/buildinacode NOA No 09- 0310.05 Expiration Date: June 10, 2014 Approval Date: June 24, 2009 Page 1 Eurotech Industries. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS (transferred from file # 08- 0507.10) 1. Manufacturer's die drawings and sections. 2. Drawing No. W04 -01, titled "Alumimim Outswing Entrance Door ", sheets 1 through 5 of 5, dated 01/15/04 and last revised on June 02, 2009, prepared by AL- Farooq Corporation, signed and sealed by Arshad Vigar P.E. B. TESTS (transferred from file # 08-0507.10) 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Water Resistance Test per FBC, TAS 202 -94 4) Forced Entry Test, per FBC 2411 3.2.1 and TAS 202 -94 5) Large Missile Impact Test per FBC, TAS 201 -94 6) Cyclic Wind Pressure Loading per FBC, TAS' 203 -94 along with installation diagram of aluminum outswing door, prepared by Hurricane Engineering Testing Inc., Test Report No(s). HETI- 08 -2021, 08 -2022, 08 -2023 and 08 -2024, all dated 03/15/08, signed and sealed by Candido Font, P.E. 2. Test reports on 1) Air Infiltration Test, per PBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Water Resistance Test per FBC, TAS 202 -94 4) Forced Entry Test, per FBC 24113.2.1 and TAS 202 -94 5) Large Missile Impact Test per FBC, TAS 201 -94 6) Cyclic Wind Pressure Loading per FBC, TAS 20394 along with installation diagram of aluminum outswing door, prepared by Hurricane Engineering Testing Inc., Test Report No(s). HETI 03 -1882, 08- 1889, 08 -18890 and 08 -2024, dated 01/15/04 thru 02/09/2004, all signed and sealed by Rafael E. Droz -Seda, P.E. (transferred from file # 06- 1019.06) 3. Tensile Test prepared by Hurricane Engineering & Testing, Test No. HETI- 04 -T100, dtd 01/29 /04, tested per ASTM E8 -01, signed & sealed by Rafael E. Droz -Seda, P.E. C. CALCULATIONS 1. Anchor Calculations and structural analysis, prepared by Al Farooq Corp., dated 04/28/08 and last revised on 06-02-09, signed and sealed by Arshad Vigar P.E. 2. Complies with ASTM E1300 -02 & -04 D. QUALITY ASSURANCE • 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS • • 1. Notice of Acceptance No. 07- 1116.04 issued to E.I. DuPont DeNemours for "SentryGlasPlus ", expiring on 01/14/2012. 2, Notice of Acceptance No. 05 1208.02 issued to "EA. DuPont Denemours" for "DuPont Butacite ® PVB" dated 02/15/01, expiring on 12/11/10. F. STATEMENTS 1. Statement letter of conformance & no financial interest, dated June 02, 2009, signed and sealed by Arshad ' Vigar P.E. 2. Statement Letter of lab compliance, part of above test reports. G. OTHER 1. This renews & revises NOA # 08 0507.10, expiring June 10, 2009. 2. Test proposal # 07 -3527 approved by BCCO. E -1 k. Ishaq 1. Chards, P.E. Product Control Examiner NOA No 09-0310.05 Expiration Date: June 10, 2014 Approval Date: June 24, 2009 11 k SEE - - 11 FOR 4 RATING ,1 1 lE NOA -I 1 11 DET#1.5 1 1 j 11 ;i lr l P [NUM OVTSWING ENTRANCE DOOR APPROVAL APPLIES TO SINGLE (X) AND DOUBLE (XX) LEAF DOORS. ALSO SINGLE AND DOUBLE DOORS IN COMBINATION WITH SIDEUTES USING MIAMI —DADE .COUNTY APPROVED MULLIONS IN BETWEEN. ALSO SINGLE AND DOUBLE DOORS WITH OR WITHOUT SIDELDES DN COLLIMATOR WITH TRAN50 45 U9 M NG MIAMI—DADE COUY APPROVED MULLION IN BETWEEN. LoYtEO DESIGN PRESSURES FROM DOOR, SIDEUTE OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT FIRS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 2007 EDITION INCLUDING HNi , VELOCITY HU�5C Own). ZONE ). WOOD BUCKS BY OTHERS. MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. ANCHORS SMALL BE AS LISTED. SPACED AS SHOWN ON DETAILS. ANCHORS EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL. A LOAD DURATION INCREASE IS USED II DESIGN OF ANCHORS INTO WOOD ONLY. MATERIALS INCLUDING BUT NOT UNITED TO STEEL/MEIAL SCREWS. THAT COME INTO CONTACT WITH OTHER DISSI ILAR MATERIALS SHALL MEET THE REQUIREMENTS OF 2007 FLORIDA BLDG. CODE SECTION 2003.8.4. aa' DOOR HINES SEE SHEET 2 FOR 4UIM DUANITfES & CAPACITY 5' VAX. HEAD /SW. CORNERS g 2 FRAME WIDTH 13' VAX HEAD /SILL I, \ / • 31 3/4' D.L OP0. 39 1/8 LEAF WEGN (2) ADOL ANCHORS AT 3' G.G. AT MTG. STILE ENDS REO. FOR 5000 OR WOOD DUCK INSTALLATIONS ONLY DOOR HINGES SUF6ACE APPLIED SEE SHEET 2 FALSE MUWDNS FOR QUANTITIES MAY BE USED & CAPACITY Nine —DACE CORNIY APPROVED MULLION SEE SEPARATE NNN / 1,1 II II / • 11 // IV /1 / 11 / 11 / a ll 11 , I 1 f SEE SEPARATE NOA FOR SIDELNE RATING AND DETAILS 29' D.L. OPG. 34 3/B' LEAF NTH THESE DOORS ARE RATED f0R LARGE & SMALL MISSILE IMPACT. SHUTTERS ARE NOT REOUIRED. 75 3/4' FRAME WIDTH 13' MAX. HEAD/SILL 29' DL GPO. 36 3/B' LEAF WIDTH Ear, M$HAD vs/AR FLA. PE 9 383 2 2 009 5' MAX. HEAD /SILL CORNERS 6DINEd8A 1 PR98UCTo 18a Baldbiggaia -/Rata of Wad= Oate O Omar ra ihIU z q � IZE AA 1 at h �8 M %'9 3; 4We11 0 8 3 l ad a. REM 9 PAST 9 OE N). OFl0HIP170N MATERIAL MANE. /BOPPLiER/REN.RKS 1 ER008 AS REED. 0008 FRAME 8083 -08 - 2 ER012 AS REGO. DOOR LEAF 11053 -18 - 3 V21866 1/ LEAF ODOR BASE BOARD 6083 -16 - 4 .50 -1483 1/ DOOR FRAME SILL 8003 -78 - 9 - 1/ 000R SILL BASE 6083 -76 - 6 1 /2 -1481 AS RE00. ASTRAGAL STILE 6083 -75 - 7 1/2 -1935 4/ LEAP 12AZING BEAD 6063 -76 - 8 2801 A5 8000. CIA2480 GASKET 91NN. - 5 - 10 1001 /00 1/ CORNER CORNER KEY ALU13828 1KXITICELLO 11 008008 4/ LEAF PONCES ALUMINUM CILSSE 12 910 X 3/8' 4/ MIKE HINGE INSTALLATION SCREWS - PH 6AL40NE SCREWS 13 - AS REED 8U18 851FOPPO0 - - 14 910 • 2' AS RECD. ASSEIS.Y SCREWS - NH SELF 019w140 13 912 X 1 -1/4 - FIORE ASSE9007 8080115 - SHE 1T1SICN LOAD CAPACITY - PSF SINGLE (2) DOORS 1400R SIZE CLAN TYPE 'B" WIDTH NEI0T EXT. ( +) 01T. ( -) 2/6 if czT 100.0 140.0 3/0 (1/9 100.0 140.0 3/3 5/0 100.0 140.0 2/6 8/4 100.0 140.0 3/0 7/0 100.0 140.0 3/3 FOR INSIS IATRMS WHERE WATER 100.0 440.0 2/8 100.0 140.0 3/0 8/0 100.0 140.0 3/3 100.0 140.0 owns APPROVED FOR NATALIp110N$ MERE WATER 1NTL1800N RESISTANCE IS REQUIRED. DE111081 WAD CAPACITY - PSF SINGLE (t) DOORS NOR 6128 GLASS TYPE 'A' WIDTH HEIGHT EXT. (4.) 841. (-) 2/8 if czT 75.0 85.0 3/0 5/8 15.0 85.0 3/6 5/0 75.0 85.0 2/6 8/4 75.0 85.0 3/0 7/0 75.0 65.0 3/6 FOR INSIS IATRMS WHERE WATER 75.0 83.0 2/8 75.0 85.0 3/0 8/o 75.0 65:0 3/8 73.0 85.0 08082 APPROVED FOR 8511WROIS WHERE 81768 WFO.IRATK4 RESISTANCE IS REOUI $D. 0561074 LOAD DOODLE CAPACITY - PIF (SE) DOORS DOOR SIZE CLASS TYPE 'A' OR '8' 1Y0)TH HEIGHT EXT. ( +) NT. ( -) if czT 8/8 ( 7/0 A 6/4 75.o 75.0 5/0 8/1 750 75:0 8/4 75.0 75.0 LOAD SHOWN .ABOVE ARE FOR X16TA11A110N8 WHERE WATER 81FIL7RATION RESISTANCE 'IS NOT REWIRED. LWO EX1E 4) LOADS TO 48 PSF FOR INSIS IATRMS WHERE WATER NFTLTRATION SESUSTA5E 1S RECEDED. JACKS SINGLE DOORS; 3 POUR LOCK SYSTEM AT ACTIVE LOCK SIRE sr FROM 8017011. REY OPERATED ON EXTERIOR AND THUMB TURN ON INTERIOR. sum PLATE 1 -1/4" X 1/4" X 18 -1/4" LONG ATTACHED STN (2) 18 X 3/4" 5MS HINGES SINGLE DOORS!. 185- NAI$1E3 COMB 1100 EXTRUDED ALUMNUM BOD68 2 BY 'CI1SSE' (5) PER LEAF AT 8'. 12 ° . 35'. 83-1/2' AND 62 -1/2" FROM TOP OF DOOR LOCKS SING111 000 S; MANUALLY OPERATED CONCEALED FLUSH BOLTS AT TOP AND BOTTOM OF ACME LEAF PART 102181 ATTACHED 8711 (4) 110 X 1 -1/2" EMS. 3 POINT LOCK 5Y61EL AT ALINE LOCK STILE 38' FROM B017OM, KEY OPERATED ON EXTERIOR AND THILMB TURN ON 11410311014. STRIKE PLATE 1 -I/4" X 3/4" X 16 -1/4" LONG ATTACHED WM (2) 18 X 3/4 WS JIINGES SINGLE DOORS; TYPO -WAILED COMB MING MINED ALUMINUM 68400E 2 BY 'OSSSE' (7) PER LEAF AT 7/0 AO 8/0 DOORS AT 3 ". 8" AND 28 -3/8" FROM TOP APO 8071011. ONE AT LOOSPAt4 1 8) 3', B' AND 28 -3/8' FROM TOP AND BOTTOM NOTE, Z 4833. BOTTOM PLUSH BOLTS MUST BE DURING PERIODS OF HURRICANE WARNING. LACKS DOUBLE DOORS; AIDE LEAF, RANUALLT OPERATED CONCEALED FLUSH BOLTS AT TOP AND BOTTOM OF ACTIVE LEAF PART 1021131 ATTACHED WIN (4) 18 X 1 -1/2' MS. 3 PON7 LOCK SYSTEM AT ACTIVE LOCK STILE 38' mom MOTHS , k0Y OPERATED ON EXTERIOR AND 1111119 TURN ON 1141E3908. INACTIVE I FAF MANUALLY OPERATED CONCEALED FLUSH BOLTS AT TOP AND DOITOM OF INACTIVE IFA7 was 102168 ATTACHED TIM (4) 95 X 1 -1/2" EMS. HINGES DOUBLE DOORS; 110- HANDED COMB NINO EXTRUDED ALUMINUM BRIDGE 2 BY '0125W (5) PER LEAF AT 8'. 12 ° . 35'. 63 -1/2' AND 62 -1/2" FROM 10P OF DOOR 3/16" HEAT 57806) GLASS .060 INIEWAYER BUTACTE 3388 BY 'DUPONT' 3/18" HEAT SIREMb GLASS GLASS TYPE %UWE- GE SCS 2800 PRQDuci ESplotho /y 4 1 • kN�6 � TE: Dh GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300 -02/04 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECIARATORY STATEMENT DCAO5 -DEC -219 3/16' HEAT STREW() CLASS .100" 041ERLAYET SE TRYGtAS PLO5 BY 'DOPOi4Y 3/18" NEAT STRE4'D CLASS LASS TYPO 'H" SILICONE CE SCS 2800 S1.GA8E CEO 0 1 `5 drawing no. W04-01 (sheet 2'3f 5 TYPICAL ANCHORS SEE ELEVATIONS FOR PANG TYPICAL ANCHORS SEE EI.EV. FOR SPACING ACCESS IVIES MTH PLUGS (4) /12 X 1' S&S � AT 2' O.C. MAX. AT CENTER OF 5[L. • REGD. AT . DOUBLE NO DOORS • ONLY 81 18 X 1/2 sMs r FROM ENDS AND 10' O.C. MAX. TYPICAL ANCHORS SEE ELEVATIONS 16Y FOR SPACING ROOD BUCIC SEE SEPARATE NOA FOR RATING AND M W - DADE COUNTY APPROVED MULLION SEE SEPARATE NOA TYPICAL ANCHORS ASNO tiithibem SEE ELEV. FOR SPACING igommggsto F110D WOOD BUCKS AND METAL STRUCTURE NOT BY EUROTECH MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. Pie AY Am/MARS' SEE MW. FOR SPACING • FV •177 X51. Fy°155 XSI) •. STRUCTURES 1 -3/8' MIN. PENETRATION INTO WOOD THRU 1BY BUCKS INTO CONC. OR MASONRY t -1/4 MIN. EMBED INTO CONC_ OR MASONRY DIRECTLY INTO CONC. OR MASONRY 1 -1/4' MIN. EMBED INTO CONC. OR MASONRY 1 /4 01*. jEKS /3RD —FLEX SELF ORR1JNG SCREWS (GRADE 5 CRS) INTO MIAMI —DADE COUNTY APPROVED MULLIONS If INTO METAL. STRUCTURES STEEL : 1/B" THK. MIN. (Fy = 36 KSI MIN.) ALUMINUM : 1/8' THK. MIN. (8063 —T5 MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) eiCAL EDGE DISTANCE INTO CONCRETE AND MASONRY m 2 -1/2' MIN. INTO WOOD STRUCTURE = 1' MIN.' INTO METAL STRUCTURE - 3/4' MIN. CONCRETE re = 3000 PSI MIN. 0 -90 IIOLLOW/F.LED 9LOCmC Pm, n' 2000 P51 ERN. SEALANTS: ALL FRAME AND LEAF CORNERS AND JOINTS SEALED WITH ADSEL OR TEKNA 50729 SEALANTS. Env: AINHAD.VIDATI ONE RA PEE 38893 CAN. 3538 JUN 0 Z 2009 � qq k 41 t drawing no. W04 -01 sheet 3 of 5 Mean Roof Height DESIGN PRESSURES PSF) • Zone 5 10 18 20 Tributary Area So FO 40 45 50 ' 25 30 35 0 -1511 -62.2 59.8 -58.0 -56.7 -55.6 -54.6 -53.8 43.1 -52.5 - 45: 5' ; +41 +45.5 +45.2 +44.4 +43.7 +43.1 +42.7 +42.3 +41.9 +41.6 .18 ft 43.1 +47.1 -60.6 +45.9 -58.8 +45.0 -57.5 +44.3 -55.3 +43.7 55.4 +43.3 -54.8 +429 -53.9 +42.6 -53.2 +42.2 18 fl -84.6 - 82.1 +47.0 - 80.3 +48,1 -58.9 +45.4 -57.8 +44.8 - 56.8 +44.3 -55.9 +43.9 -552 +43.6 -54.5 +43.2 '+44.9 +44.5 +44.2 5 -61.6 -802 -59.0 58.1 572 •56.4 55.8 ':.1 +47.1 +46,4 +45.8 +45.3 +449 +44,6 +44,2 ._. - - ' .. - 84.6 - 829 - 81.4 -802 - 59.2 -58.4 57.8 -56.9 • +BOA +49.0 +48.1 +47.4 +46.8 +46.3 +45.8 +45.4 +45.1 52.9 48.7 48.0 -64.1 -62.6 -61.4 -60.3 -59.4 -58.7 -58.0 28 ft +51.3 +49.9 +49.0 4-48.2 +47.6 +47.1 +48.7 +48.3 +45.9 26 ft -89.8 +622 -87.1 + 5 0 . 8 48.1 +409 - 83.8 +4E61: -62.4. ∎-814 ;548,4 +47:8' .: -60.4 '$. - 59.6 ' 447.1 -58.9 +45.7 28 ft 70.9 482 382 - 64.6'' - 53:4';..62.3 • _., :.''6) .4' 60.5 -599 -55.4 -84.9 +50.7 +502 -56.1 56.6 +51.3 +509 A 4 4 V c4 c4 Ti 4 +63.0 +51.6 +50.6 +49:8's ;� 19.2. +48:7_ '446;2:2=447.8 +47.4 -59.8 48.7 -69.2 -67.1 .666 _ -FI43_ ;.-63 ; '4V1' +55.0 -60,7 +53.1 +539 +52.3 +51.3 +50:8' .449', ' 4494 4 4829= F.4@, +48.1 32R - 7 0. 1 +53.1 -88.1 +62.0 -86.5 +51.3 7652'...1., +50.8 414.1.:= +50.1' -453.1 +49.6 :r,3 +49,2 -81.6 +48,8 34 ft ‘1 -71.0 +53.7 -58.5 '4171• 456.01.. - +51:9 ' 4 51'. 64:9 4 :7 4" 1' 1 " $2.4 +:49.4 38 ft +53 :0= +52:5 > "t52 -...ciM:7. - 71.9 +54,4 - 632 -58.7" +52.5 - - 88;8". +51.9 -65:7 ; +51.3 -59.1 -63.1 +50.0 38 ft -75.7 +58.5 -72.7 +55.0 -70.6 +54,0 -68.9 +53.1 -67.6 +52.5 - 88.5 +519 - 65.6 +51.4 44.8 +61.0 -63.8 +50.6 412 +56.2 - 78.5 -73.5 -71.3 -69.7 -682 -67.2 -66.2 453 44.6 -59.8 49.0 -58.2 _+•54:5'• = +54:0 �: +53.1': +57.1 +55.6 +54.5 +53.7 +53.0 +52.5 +52.0 +51.5 +51.1 +58.3 -77.3 742 72.1 -70.4 - 69.0 -67.9 -68.9 46.0 452 - 812 +57.7 +562 +55.1 +54,3 +53.6 +53.0 +52.5 +52.1 +51.7 .68.0 +60.8 78.0 -75.0 72.8 -71.1 49.7 -68.5 - 67.5 -86.6 -85.8 -62.9 +58.3 +56.7 +553 +54.8 +54.1 +535 +539 +52.8 +52.2 80 R -78.8 - 75.7 -73.5 -715 -70.4 -692 482 47.3 58.5 +589 +87,3 +562 +55.3 +54.6 +54.0 +53.5 +53.1 +52.7 78.3 -74.1 -72.4 71.0 -89.8 -68.8 -87.9 -87.1 ® -79.5 +59.4 +57.8 +58.7 +55.8 +55.1 +54.5 +54.0 +53.6 +53.1 50 ft -80.2 +599 77.0 +58.3 -74.8 +57.2 -73.0 +56.3 -71.6 +55.6 -70.4 +55.0 -69.4 +54.5 - 88.5 +54.0 -67,6 +53.6 528 -809 +60.4 - 77.6 +58.8 -75.4 +57,8 - 73.6 +56.8 -722 +56.1 - 71.0 +55.4 -69.9 +54.9 - 69.0 +54.5 -68 -68.2 +54.0 ft -81.5 +309 - 78.3 +592 78.0 +58.1 -74,2 +572 -72.8 +56,5 -71.8 +552 - 70.5 +55.4 -89.6 +549 48.7 +54.5 56 ft -82,1 +613 -78.9 +59.7 78.8 +58.5 -74.8 +57.7 -73.3 +58.9 -72.1 +56.3 -71.0 +555 -70.1 +55.3 -68.3 +549 60 ft -83.3 +522 - 80.0 +605 -77.7 +59.4 75.9 +68,5 74.4 +57.8 -73,2 +57.1 -72.1 +585 -71.1 +55.1 -70,3 +553 Mean Roof Height DESIGN PRESSURES 7 , „ --, Area (P &F) • S. FS Zone 4 .. 40 .. _. 45 .. "'f)0' - 10 15 20 25 30 3G 0 -15 ft -50.4 t46,8 -49.2 +45.2 -48.3 +44,4 -47.6 +43.7 -47.1 +43.1 - 46.8:. +421, -462 :' 4422 :46-0-: +41:9 - 45: 5' ; +41 18 ft -51.1 +47,1 -49.8 +45.9 .49.0 +450 - 48.3 +44.3 -47.7 +43.7 -472', X401.. +439 -46:5^ 442:5.'+42:2 •'4459: 18 It -52.4 -57.7 +47.0 -502 +48.1 -49.5 +45.4 : • , : : • 48:0 ": =r)7, +43.9 +43.8 +43.2 _ .. -53.5 L.. .2 -51.3 -50.6 - 50.0 -49.6 .:; -49.7 • -48.7. • +47:1 '+44.9 +44.5 +44.2 - 52.4 40:1' - 49.7 -49.4 *48.1 +48.8 +48.4 +45,1 -532 51.0 -60.8 -50.3 +51.3 +49.9 +49.0 +482 47.8 +47.1 +48.7 +482 +45.9 552 -54.2 -53.5 52.9 -52.3 51.9 - 51.5 -51.1 - +50.8 +49.8 +49.1 +48,4 +47.8 +47,5 +47.1 +46.7 28 ft -57.5 +53.0 56.1 +51.6 - 55.1 +50.6 54.3 +49.8 -53,7 +49.2 -53.2 - 52.7 52.3 -51.9 +48.7 +48.2 +47,8 +47,4 30 ft -58.3 +53.8 -56.9 +52.3 -55.9 +51.3 -55.1 +50.8 -54.5 +49.9 2 -53.9 53.5 -53.1 5.7 +49.4 +48.9 +48.5 +48.1 ®R -57.7 +53.1 -56.7 +52.0 -55.9 +51.3 -552 +50.6 54/ - 54.2 539 -53.4 +50.1 +49.8 +49.2 +48.8 34 fl -59.9 +55,2 48.4 +53.7 -57.4 +523 A A -55.4 -84.9 +50.7 +502 -56.1 56.6 +51.3 +509 A 4 4 V c4 c4 Ti 4 36 ft 40.8 +559 59.1 +54,4 -55.1 +53.3 -51.3 -59.8 48.7 -57.9 -57.3 - 58.7 462 -55.8 -55.4 +58.5 +55.0 +544) +53.1 +52.5 +61.9 +51.4 +51.0 +50.6 42.0 -60.5 -59.4 - 58.6 -57.9 -57.3 58.8 x 48.4 -58.0. +57.1 +55.6 +54,8 +63.7 +53.0 • +52.5 +52.0 +51 :5' +31:1 • -62.6 41.1 -50.0 -592 -58.5 570•, "37.4 - 57.Q• : .8 +57.7 +562 +55.1 +54.3 453.8 +53 :0= +52:5 > "t52 -...ciM:7. - 632 -61.7 -603 59.7 -59.1 584:, -58.0 .57:8 - :.47:. ,, .. +58.3 +58.7 +55.7 +54.8 +54.1 +53:5: +530 : +52:8 4$212;; 40 ft -63.8 +58.8 -62.3 +57.3 412 +56.2 -60.3 +55.3 - 59.6 +54.5 - 59.0' 485 . -58.1 573'- +54.0 +53.5 48 fl - 64.4 +59.4 -62.8 +57.8 41.7 + 56.7 -50.8 +55.8 40.1 +55.7 -59.8 49.0 -58.2 _+•54:5'• = +54:0 �: +53.1': -644.9 43,4 4122 -81.4 40.7 -60.1" -59S -59.1 -58.7. +59.9 +58.3 +572 +56.3 +55.6 +55.5 +54:5 +54.0 +535' 45,5 53.9 428 41.9 - 812 - 60.8 50.0 -59.6 -592 +60.4 +58.8 +579 +56.8 +56.1 +55.4 +54.9 +54.5 +54.0 64 ft .68.0 +60.8 -64.4 +592 53.3 +58.1 -62.4 +572 -51.7 +56.5 9 41.0 -50.5 -80.1 5.6 +55.9 +55.4 +549 +54.6 - 86.5 - 64.9 53.7 -62.9 42.1 -51.5 -61.0 - 605 40.1 +81.3 +59.7 +58.5 +57.7 +56.9 +58.3 +55.8 +553 +54.9 80 R -67.5 +622 -65.8 +80.8 54.7 +59.4 -63.8 +585 - 83.0 +57,8 42.4 -61.9 41.4 41.0 +57.1 +56.8 +56.1 +55.7 0302/2009.5:01pm F:103 Etement:MO Loading 111 Calculator&ASCE 7.054 FLB -ASCE 7-02 Presawe C0a183 (0- 60),dwg 200 FLORIDA BUILDING CODE & ASCE 7 -05 D LOADS FOR COMPONENTS AND CLADDING INTERIOR ZONE 4 PRESSURES 1 1 EXTERIOR ZONE 5 PRESSURES 1 WIND VELOCITY =146 MPH EXPOSURE 'C' a= 1011 OF LEAST HORIZONTAL •DIMENSION''OA WHICHEVER 15 SMALLER, BUT NOT LESS THAN 41a OF LEAST HORIZONTAL. DIMENSION OR 3FT (lm). USE ZONE 5 IF AT ALL'IN QUESTION. CONSULT AN ENGINEER FOR AMORS SPECIFIC INTERPRETATION IF REQUIRED. { l O f Q 1 1 ELEVATION WALL ZONE FIGURES MRH =O -60'I BASED ON Kd =0,85 SEE TABLE NOTES FOR ALT Kd INSTRUCTIONS FOR TABLE USE I. TABLES ARE INTENDED TO. DEPICT THE 'WORST CASE' PRESSURES. 'WORST CASE' IS DEFINED AS THE CRITICAL CONCom0N ANY UNKNOWN VARIABLE AS DESCRIBED BELOW. USE OF CRITICAL CQNDITIONS'REQUtRFP;FQR_(USE WITH THESE TABLES. 2. FOR Sr T UATIONS:TAT'1REQU RE•:ICd •'.7s0 ;FABLE VALUES ARE UNDER - DESIGNED BY A FACTOR OF LIB. VERIFY Kd`RFQI6RRE�MEN75 LOCAL MUNICIPALITY PRIOR TO TABLE USE. 3. USE OF TABLES VALID ONLY LESS THAN 60' MEAN ROOF HEIGHT. 4, TABLES VALID Fps ALtRoOF F,LOPES; (EDUCTIONS FOR ROOF SLOPES LESS THAN 10° SHALL BE PERFORM 15Y AN'ENGTNEEIT'AS) LSITE SPECIFIC CONDITION, 5. IDENTIFY THE BUILDING.MEAN'{AVERAGE);ROOF HEIGHT. IF THE MEAN ROOF HEIGHT CANNOT BE IDENTIFIED, PEAK: "ROOF HEIGHT. 6. ALWAYS ROUND UP ROOF HEIGHTS TO NEXT TABLE VALUE OR TO A CONSERVATIVE ASSUMPTION. . 7. CALCULATE THE::TRIBUTARY AREA>OF''THE IN QUESTION (HEIGHT 4 WIDTH) OR THE SPAN LENGTH (HEIGHT) MULTIPLIED BY•AN EFFECTIVE WIDTH THAT NEED NOT BE LESS THAN ONE -THIRD THESPAN..CENGTF)'.(HEIGHT:2 / 3). USE THE AREA BETWEEN STRUCTURAL OPENINGS ONLY - THIS INCLUDES AREAS BETWEEN STRUCTURAL MULLS. IP THE TRIBUTARY AREA OF AN OPENING CANNOT BE IDENTIFIED, THE MOST CRITICAL (10 SQUARE FEET) SHALL BE USED. ALWAYS ROUND TRIBUTARY AREA DOWN TO THE LESSER TABLE VALUE, FOR LARGER TRIBUTARY AREAS THAN PUBLISHED, USE THE LARGEST PUBLISHED VALISE, 8, IDENTIFY THE ZONE OF THE OPENING AS INTERIOR (ZONE 4) OR EXTERIOR (ZONE 5) PER THE FIGURE OR INFORMATION BY OTHERS. ANY QUESTIONABLE OPENING IS TO BE CONSIDERED THE MORE CRITICAL (EXTERIOR) ZONE. 9. READ OFF POSITIVE AND NEGATIVE PRESSURES FOR USE AS REQUIRED BY THE LOCAL MUNICIPALITY IN ACCORDANCE WRH CODE, GENERAL NOTES: 1. THESE CHARTS ARE NOT VALID AS A SITE - SPECIFIC DRAWING. THESE TABLES ARE ONLY VALID WHEN SIGNED & RAISED SEALED BY FRANK L, BENNARDO, P.E. 2. THIS SPECIFICATION IS INTENDED TO ILLUSTRATE DESIGN WIND PRESSURES AS LISTED. USE OF THESE TABLES AND CORRESPONDING WIND VELOCITY, EXPOSURE, AND OTHER COEFFICIENTS LISTED HEREIN SHALL BE DICTATED AND VERIFIED BY THE GOVERNING BUILDING DEPARTMENT AND PERMIT HOLDER. NO WARRANTY FOR APPLICABILITY OF TABLE VALUE USE 1.5 OFFERED HEREIN. 3. THL5 SPECIFICATION I5 NOT INTENDED TO OFFER ANY PRODUCT APPROVED CERTIFICATION. REFER TO ANY SEPARATELY SUBMITTED TEST CRITERIA AND OTHER APPROVALS FOR DESIGN & INSTALLATION INFORMATION AND APPLICABILITY OF THESE TABLE VALUES WHICH IS TO BE VERIFIED BY OTHERS IN ACCORDANCE WITH GOVERNING CODES. 4. DESIGN IS BASED ON THE.;g ; COND. GUST (WINO VELOCITY) FOR A CATEGORY rl (GENERAL RESIDENTIAL & COMMER . , -' GU CQNSTRUCTION) USING AN IMPORTANCE FACTOR 1.1,0. THESE TABLES'N07 FORUSZ THISS.ENTIAL FACILITIES OR ASSEMBLY OCCUPANCIES. TOPOGRAPHIC FACF0R:Kat 1:0'1'OR FTA'L`_` 6111tA1N USE ONLY THESE TABLES NOT VAUD FOR HILLY TERRAIN. INT6) 1AL'PRESSQRt,OEFF1dENT (GCpI @ +/ -0.18) ENCLOSED BUILDING ONLY. VERIFY USE OF Kd•.0 85i((DIRECTIQNALTt'tFACTOR) WITH LOCAL BUILDING DEPARTMENT. HVHZ HIGH HURRICANE'ZONE TABI;.ES;AAE FOR WALLS AND VERTICAL SURFACES ONLY. 5. ADHERE TO ALL !.I:QCAI,1MPAIGT'PROTEG'1'ION SYSTEM ORDINANCES. 6. NO CERTIFICATIDN'ISVFFEREWMOTHEINTEGRITY OF THE HOST STRUCTURE, 7. EXCEPT AS EXPRESSLY PROVII)E19'RERE4N, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. PEAK ROOF F535447 MEAN ROOF HEIGHT z 1" REMARKS INR ISSUE REVISE FOR 07 FBC DRINK Cl. TSB CHKD FL.B FL8 DATE 04/19106 02/23/09 Tms DOOUMENT B THE PROPERTY OF FRANC 9E64A110O, PIANO SHALL NOT BE REPRO1TUl2D N WHOLE OR PART WITH= MUM CONSENT OFFRANILLSENNAITDO,RE ALTERATION& ADDMONS, HIGHLIGHTING, OR OTHER MNP4INGSTOTHH DOCUMENT ARE NOT PER5ATIE0 AND INVAL91AT6 OUR t RTINOATE & 2007 FLORIDA BUILDING ASCE 7 -05, MRH = 0 - 60 FT DESIGN LOADS FOR COMPONENTS & CLADDING CODE ENGINEERING EXPRESS' 160 SW 12th AVENGE, #106 DEERFIELD BEACH, FL 33442 PH: (954) 354 -0660 FAx: (954) 354 -0493 WWW.ENGEXP.COM CERT OF RUTH 59855 r MIAMI SHORES BUILDING DEPARTMENT PRODUCT APPROVAL SCHEDULE / COMPARISON CHART Address: 1030 NE 95 ST, MIAMI SHORES FL 33138 'Permit No. Opening ID Window, Door or Mullion Product Acceptance # Product Approval Design Pressure Opening Design Pressure Rough Opening Size Shutter Required Yes / No Mullion Required Yes / No Impact Yes / No 1 DOOR 09- 0310.05 75.0 -75.0 49.4 -53.5 72 x 79 3/4 NO NO YES