FENCE PERMITBUILDING
ELECTRICAL
PLUMBING
ROOFING
Owner of
Building
MIAMI SHORES VILLAGE. FLORIDA
DATF 195
❑ PERMIT N9 2930 Contractor's
License No.
❑ Work to be performed under this Permit
Architect
Contrac tor
or Builder
Legal Lot
Description
Address of
Building
CONTRACTOR OR BUILDER
Bl.
Subdi-
vision
Value of
Project $
I Amount of
Permit $
This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application
herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any p'.ans,
drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any
time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is
granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations
pertaining to the work covered hereby whether shown on the plans or drawings cr in the statements or specifications and that he assumes responsibility for work
done by hs agents, servants or employees.
Signed. BY
INSPECTOR
In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In ac-
cepting thi: permit I assume responsibility for all work done by either, myself, my agent, servant or employee.
e'
t.
BY AUTHORITY 6 •� . =
STATE OF FLORIDA,
COUNTY OF DADE. ss.
MIAMI S H O RES VILLAGE
UILDING INSPECTION DEPARTMENT
APPLBCATI !yN FOR BUILDING PERMIT
Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build-
ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
r°
Date M.< J7G;l.a ,19 2.
�
Owner's Name and Address �.'O_�_u ^�� �1I:(r`����d E No._.kY Street__ .a, 7(f=G
Registered Architect and /or Engineer..
�i:a� a
Name and address of licensed contractor _14��n1
_C- �,aS`Z!_a111c `� C�.� C C? o _.�.Q_� D �,.�[��,_.__ Y541n1,_._AeL. o
Location and legal description of lot to be built on:
Lot Block Subdivision
Street and Number where work is to be done �___�_�r!�1c 9 �?
State work to be done and purpose of building (by floors)
4 /O 6A1 �__ Z o i 0 !`; 2C4L Cap_aln2 eDIa).
and for no other purpose.
New Building Remodeling Addition Repairs No. of Stories
To be constructed of Kind of foundation lJ pf Covering
Estimated Total cost of improvements $.___�_� a_. Q� Amount of Permit $ !�
Zone cubage required plan Cubage
Distance to next nearest building Size of Building Lot
Ma•dmnm live load to be borne by each floor
I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may
be sent to
The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer
of Iabor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Pennanent Supplement,
and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him
in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such ublic notice
or notices as are required by the Act. The undersigned agrees to employ only such su ntractors, on wo to be performe nd .this
pennit, as are licensed by Miami Shores Village.
Remarks (Signed) . VX/ a 2;c s
Notary Public, State of Florida
Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap-
peared
to me well known,
and who, being by me first duly sworn, upon'oath deposes and says that he is the_
of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts
therein by him stated are true.
Permit No.__ Date Read, Sworn to and Subscribed before me.
Disapproved Date
(Signed)
Building Inspector My Commission Expires
PLANNING BOARD DATE
Chairman Member
Member ____ Member
Member Member
Council Approved Date Disapproved Date
NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from
the Planning Board.
A re- inspection fee of 81.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty
materials and /or workmanship.
1 87/
41
6 Si CI
/03'
3/zo
Che,mi illy& FE/itE)
- / - "j7" -
"au f 65
/ 77o
c\f
r i \
3 0.. V
, 7
/0'
1
Date <d* 0 Job / � & , [ //, Y, Tax Folio
A % - , — i' ,P4 • .— .e..)5
Legal Description ; �G 7 / 4 _ 3 Tf , 2 / Historically Designated: Yes No �
n /Test ) 4"e
Owners Address J5 4 % � �'� �s f S �/-� � / Phone -�\ 5� f
Contracting Co. e) 4
Qualifier
State #
Architect/Engineer
Bonding Company
Mortgagor Address
Permit Type (circle one):
WORK DESCRIPTION
.1 ` 7i .' 65 ,�� / f � ?:Pc'! 7 % — f't:
Square Ft. Estimated Cost (value))
WARNING TO OWNER: YOU MUST REC RD A NOTICE OF COMMENCEMENT AND YOUR FAILURE T • DO SO MAY RESULT TN YOUR
PAYING TWICE FOR ft P ROVEMENTS TO Y'I UR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER
OR AN ATTORNEY BEFORE RECO'': ; 10 ING YOUR NOTICE OF COMMENCEMENT.)
APPROVED:
Zoning
° ° " nical
My Commission Expires:
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Municipal #
Signature of owner and/or Condo President
Notary as to Owner an or Condo 'dentcy:t
614/
Building 'u
It
C.C.F.
SS#
Competency #
Address
Address
(ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING
Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work
will be perfonned to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL
PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated.
/Signature of Contra
Date
R1 .
GLADYS5W Y a
cNa2Al2Y'f;TIL C STA`,;" u"Ts ..sZ:: s" yl ,
TOTAL DUE
Date
SIGN
Plumbing Structural Engineer
OWNER
MARK & ROSALEEN HOERBER
990 NE 92 ST
MIAMI SHORES FL 33138 -2911
PROPERTY: Subdivision: AMD
LESS S7.24 FT A /K /A 990 NE
Although you are not currently being assessed any additional
fees, fines, and /or lot clearing charges in association with
your code violation, a balance of $15.00 still remains
unpaid. A lien may be filed against your property for
non - payment.
This matter requires your immediate attention.
WN /vg
CASE #: 008920
COMMUNITY AFFAIRS AND CODE ENFORCEMENT DIVISIONS
10050 N.E. SECOND AVENUE
MIAMI SHORES. FLORIDA 33138.2382
TELEPHONE 13051 795.2204
FAX (305) 756-8972
06 -01 -00
TENANT
MARK & ROSALEEN HOERBER
990 NE 92 ST
MIAMI SHORES, FL 33138 -2911
PL GOLDEN GATE PK PB7 -54 Lot: 18
92 Street
Sincerely,
Richard Trumble
Code Enforcement /Community
Affairs Specialist
CASE NO.(S)
MIAMI SHORES VILLAGE
APPLICATION FOR REQUEST FOR RELIEF
FROM CODE E`r E\T LIENS
OWNER(S) NAME:
TELEPHONE NUMBER:
MAILING ADDRESS:
ADDRESS OF LIENED PROPERTY:
LIENS AT ISSUE:
DATE OF LIEN(S) CURRENT AMOUNT(S)
TOTAL: S
REASONS WHY RELIEF SHOULD BE GRANTED (artach additional sheets if
necessary):
TOTAL AMOUNT WHICH YOU PROPOSE TO PAY IN FULL SATISFACTION OF
ABOVE REFERENCED LIENS: S
I (WE) request relief from the above referenced liens for the reasons herein set forth.
HAMSWASV-GEN1PLEADINGStsplicuioa for request of relief from lie=
SIGNATURE OF APPLICANT
SIGNATURE OF APPLICANT
abD
/%°'
LID
a
l��
;? '►� EDGECOCK.
10 1
9
50
10
50
N. E.
B
7
13
5
4
92
ST
14
is
151-0C1 C-1. 3►sc&Y+VE
11
3 Z 1 d
50 lol. 2
RI c G
g0
)1
Locix
CERTIFICATION: I Herby Certify that
tke Survey of the property described
t Freon is true and corr to the
c4 of my knowledge z nd teref as
recently surveyed under my erection
and !h. there are no roechments
tJnl. hciwr Dr
g. Surveyor No. 1015 State of Florida
According to Plat Book...7 Page.54,.of
the Public Records of Dade County, Fla
Go.
14 N. I2F•th Si -
NOR l it mtAmi, FLORIDA
Su1VE
LOT 18 LESS SOUTHZ.24
Am EN D ED PLAT
GOLDEN GATE. PA la K.
VILLAGE OF MIRMI SHORES, FLA.
4 t
WALL .
0.7 ' B L0(X.
•
WALL_
�•1�G
X1O
"Ln
c1
P /PE
f /PE
• C
/03.
/ 1 N
TaZ C�2.� JEt_ LQ' i
t "-■,.
� � (� ,1
'%,,, ,, .,,
D E.TA %L
SCALE I 20'
92'x® ST.
•
'LC lC
cjear {
J �
y ,u
A"4C.
0
25
K. E►1Get. Lo
PO L.E.
25
1-;01. tom. JAL) 1 ± St54
H PT, ice, )9E,5
5' -0 " MAX
2'-0"
WOOD FENCES
j e- a ir < , c;4-r-� 771L '7•,.x 4T'
4 00 $Qu 7
4" X 4" Wood post
2" X 4" Wood Rail
4
a
d °
I "X "orI "
Wood pickets
Concrete
B
2915 Fences
Wood Posts
4' -0" High or Less = 6' -0" O.C.
5' -0" High or Less = 5' -0" O.C.
2915.1 Wood fences, so located on a property
that by zoning regulations they cannot be used
as a wall of a building, shall be constructed to
meet the following minimum specifications.
(a) Fences not exceeding 5 feet in
height shall be constructed to meet
the following minimum
requirements: from nominal 4 inch
by 4 inch by 8 feet -0 inch long
posts spaced 5 feet -0 inches on
centers, having a fiber stress of
1200 p.s.i. in bending, and shall be
embedded 2 feet -0 inches into a
concrete footing 1 foot -0 inches in
diameter and 3 feet -0 inches deep.
Other components shall be
designed to comply with the
provisions of this Chapter and
Chapter 23.
(b) Fences not exceeding 5 feet and 4
feet in height respectively shall be
constructed as provided in
paragraph 2915.1 (a) herein,
except that the spacing of posts
may be increased to 5 feet -0
inches and 6 feet -0 inches on
centers for these heights.