Loading...
WS-08-1180Project Address 80 NW 93 Street Miami Shores, FL 33138- Owner Information MILTON MIZELL Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Type of Work: 1 DOOR, 2 SHUTTERS No of Openings: 3 Additional Info: IMPACT Classification: Residential Fees Due CCF Education Surcharge Notary Fee Permit Fee Scanning Fee Technology Fee Total: Amount $0.60 $0.20 $5.00 $130.00 $6.00 $3.25 $145.05 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, 1 authorize the above -named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Agent Building Department Copy Wednesday, July 9, 2008 Address OVL .. Expiration: 01/05/2009 Parcel Number 1131010170020 Block: Lot: 80 NW 93 Street MIAMI SHORES FL 33150 -2233 Phone Valuation: Total Sq Feet Total I Amt Paid 1 Amt Due $ 0.00 $ 0. Payment Type: J $ 0.00 10 i PAID ,At (17 nn Applicant MILTON MIZELL Available Inspections : July 09, 2008 Date CeII (305)758 -1836 (305)494-5222 $ 1,000.00 0 Final Shutter Attachment Inspection Type: Window Door Attachment Final Shutters 1 BUILDING PERMIT APPLICATION FBC 2004 Permit Type (circle): Building Value of Work For this Permit $ '7'0D ��' Type of Work: ['Addition ['Alteration Describe Work: Lei Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit No. ■415 O8 I'10 Master Permit No. Roofing Owner's Name (Fee Simple Titleholder) kAlt��vv) Z- LL- Phone # S) cq Owner's Address )J• (,A„) , g3 SI City 441,4 ■NA 1, int_c"_ State C— ZIP ` 1 Tenant/Lessee Name Phone # Job Address (where the work is being done) 'O ST City Miami Shores Village County Miami -Dade Zip S VS FOLIO / PARCEL # Is Building Historically Designated YES NO kr Contractor's Company Name ®W,A.rf__/(_- Phone # C 0 S) Contractor's Address City State Zip Qualifier Name Phone # State Certificate or Registration No. Certificate of Competency No. Architect/Engineer's Name (if applicable) Phone # Square / Linear Footage Of Work: ❑New ❑ Repair/Replace ❑ Demolition * * * * * * * *** * **: **** : * *** * **** **** ** *** **F *********** ** ************** *********** Submittal Fee $ 0 Permit Fee $ '' q CCF $ Notary $ ).0 Training/Education Fee $ 0' /1J Technology Fee $ 3 •1.-"S Scanning $ (. '00 Radon $ DPBR $ Bond $ Code Enforcement $ Double Fee $ c (� Structural Review. $ Total Fee Now Due $ 14 OS See Reverse side -, CO /CC Zoning $ • Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Ian (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for FT F,CTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Sign: Print: (Revised 07 /10/07) Signature g► - 3�_ 0 wne j or Agent _ The foregoing instrument was acknowledged before p� mee this k Z day of Yl(Z , 200L, by nark 4� kjz.d who is personally known to me or who has produced f iranvtt /3 NOTARY PUBLIC: • My Commission Expires APPLICATION APPROVED BY: As identification and who did take an oath. Sign: Print: My Commission Expires: **** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** :****************** ****: x** ******* ************* **** * *** ****** * * * *****•x*** \r.i®2 7- 3 —dr ► Signature Contractor The foregoing instrument was acknowledged before me this day of , 20 _ , by who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Plans Examiner Engineer Zoning OWNER BUILDER DISCLOSURE STATEMENT k VILLAGE OF MIAMI SHORES NAME: 11 yri v`7 ,ll.t I 1 [ DATE: 6/2. ADDRESS: o k). (..t,>. q 3 ci oulA A A( S' Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, F.S 489.103(7). And I have read and understood the following disclosure statement, which entitles me to work as my own contractor; I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor. You have applied for a permit under an exception to the law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the construction yourself. You may build or improve a one - family or two- family residence. You may also build or improve a commercial building at a cost of $25,000.00 or less. The building must be for your own use and occupancy. It may not be built for sale or lease. If you sell or lease a building you have built yourself within one year after the construction is complete, the law will presume that you built for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person as a contractor. It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F.I.C.A and with - holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, buildings codes and zoning regulations. Please read and initial each paragraph. 1. I hold title to the above property and I am planning on doing this construction Myself. Initial 2. I understand that as an owner- builder I must abide by all zoning ordinances and building regulations in effect at the time of permit application. Inactive permits for a period of over 180 days will become null and void (expired) and a new permit will be required to be issued for reinstatement of the permit. RI!CIEIIVE 8 2008 3. I have an understanding of' the 2004 FBC & FRC and understand that this department and its inspectors are there to help enforce and interpret the code. There is a copy of the code in this office for review. Initial IISo 4. :I understand that the building official and inspectors are not there to design, alter or give advice on how to meet code — only if the structure meets the " ` minimum code. Initial 5. I understand that as an owner - builder, that any contractor disputes with sub- contractors and myself must be handled in a civil court with the advice of an attorney. The department will not mitigate any contract disputes. 6. I understand that if I compensate any person or company for work performed they are required to have a business license in the county. If for any reason they do not posses a business license I will be responsible and liable for any wrong doing from this unlicensed company or person. 7. I understand that if any person gets injured on my construction project—they are entitled to workmen's compensation. And if they do not posses a workmen's policy I could be held liable for all doctor and related cost which could include loss of wages during recovery from injury. Initial 8. I understand that under state and local laws I can not do any Electrical, Plumbing, Heating, Air & Roof work on my property with out first obtaining the proper permits by licensed contractors. Was acknowledged before me this 2.6 day of - 6 6 4 E— , 20 0 P B Ji ,titteill Produced there License or a ues 1..i Initial Initial who was personally known to me or who has as identification. �,: ,rN'••, MONICA USSEfHDIAZ :A. MY COMMISSION # DD 483995 luiiln,I � -.. a,' EXPIRES: October 20, 2009 ARA °Q' Bonded T tu Naary PublicUndeneters 2. Job Name 3. Job Address t�o AJ& 4' S f re_S `7?/iainu" ,Wores, ('G 4. County • 5. Building Height : /3 r ft. (see sketch below) 6. Basic Wind Speed : / mph 7. Wind Standard : ASCE 7 -02, FBC 2004 Edition 8. Roof Slope • ° Flat k Slope: Pitch / 12 9. Exposure : 0 Non Coastal 0 Coastal ° Other (Coastal exposure applies within 1500 ft of ocean line or 50 miles within ocean line for Std. Bldg. Code Chapter 16.) 10. Building : Length 53 ft. Width COO 11. Attach floor plan with shutter / window, sizes and types. (Note: If maximum load used for all openings 12. Building Category : , �t ( Client Representative • • • • • • •• • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • A1- Farooq: ddrpotion ta 1235 SW 87 h Avenue • Miami, FL 13174 Tel: (305) 2611 Fatxt{305) 36 -;6978 ' C ® 3 • � ...: • .. -S. is `p„ • • Site Specific: WinciLoods iv" 2O °6 .DUN 2 X04 (Based oftdatiati lie$ iyalient') Bldg. > 60 ft. Bldg. < 60 ft. •• • • • • • ••• •• is os- C?c0 ft. Dr. Humayoun Farooq, P.E. — FL # 16557 EB C.A.N. #3538 • • .•. • • • • .. •• • • • • • • • . • • • • . • . • • • • • • • • • • • ••• • AL- FAROOQ CORPOiATfON �•• 1235 S.W. 87th. AVENUE MIAMI, FL. 33174 PH. 305 - 264 '$14T0 .'• •.• •.• • • •. • • •• • • • • • • • • • CUSTOMER :MILTON MIZELL°.• ••• ••• ••• • PROJECT :80 NW 93 ST .. • • • •• ••• •• WIND LOAD ANALYS FOR COMMIES'= 23 ) CLADDING AS PER SPECIFICATION ASCE 7.0�2 • • • ••• BUILDINGS WITH IMPACT PRO'I BASIC WIND SPEED V : 146 MPH IMPORTANCE FACTOR I : 1 EXPOSURE CATEGORY : C MEAN ROOF ELEVATION H : 13 FT. TRIBUTARY LOAD AREA A : 10 FT Kh = 0.85 (TABLE 6 -3, P75) Kd = 0.85 (TABLE 6 -4, P76) Kzt= 1.0 (TOPOGRAPHIC FACTOR) VELOCITY PRESSURE Qh= .00256 Kh Kzt Kd IV "2 = 39.43 PSF GCp COEFFICIENTS (FIGURE 6 -11A, p57) ZONE 4 = +1.00 -1.10 ZONE 5 = +1.00 -1.40 GCpi COEFFICIENTS = + .18 - .18 (TABLE 6 -5 p49) DESIGN PRESSURE P = Qh(GCp - GCpi) ZONE 4 = + 46.5 PSF ZONE 5 = + 46.5 PSF - 50.5 PSF - 62.3 PSF 06 -10 -2008 3§'at_86 ___.__. 1 -17X 34 � • • • • • • • . . • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • •• • • • • • ••• • • • • • • • • • • • • • • • • • ••• • - ..• • • • CJ Ivy- • 1 t- /` ..4e'4,-). .q, ...6/ • • • • • • • • /1/4 0r9:' . � Oi.si atlzs' J / / l x/7, & /rrS Florida Storm Panels • • • • •• • • • • • • • • • • • • •• • •• •• • • • • • • • • • • •••• •••• • • • • • • • - •• • • • 14475 N.W. 26 Avenue • Opalocka, FL 33054.685- 9990.685 -9000 • FAX 685 -7511 •• • • • •• ••• •• • • • • • • •• • • • • • • •• •• SHUTTER PRODUCT APPROVAL AUTHORIZATION FORM Building Official Dear Mr. Building Official: We are Dade County Notice of Acceptance holder for the 22gauge panels under number 07= 0'817.03 r This letter authorizes '`` //77;e1/ / Z' Z L // to use our 22ga. Panels under number 07- 0817.03 to be used at the ollowing job: R® h ") 6 13 s7 f Sincerely, Victor . C Enrique Revilla President or Vice - President 1. This form must accompany the application for building permit and shall become part of the permit documents. 2. The authorized signature must bear the raised corporate seal of the _. company holding the Dade County Notice of Acceptance. • BUILDING CODE COMPLIANCE OFFICE (BCCO)• • • • • PRODUCT CONTROL DIVISION • • • • • • • • • • • • • • •• • • • • • • ••• • • • • • • • • • •• •• • • • • • • • • • • •• • • • • • • • • • • •• • • • • ••• MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING • 144) WEST FLAGLER STREET, SUITE 1603 • • • • • • • • • • MIAMI, FLORIDA 33130 -1563 • • • • • • • • • • • • • • • (305) 375 -2901 FAX (305) 375 -2908 NOTICE OF ACCEPTANCE (NOA) www.nuamidade.gov Florida Storm Panels, Inc. • • • • • • • ••• • • 14475 N.W. 26 Avenue • • • • • • • Opa- Locka, Florida 33054 • • • • • • • • ••• • • SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 0.029" (min.) Galvanized Steel Storm Panels Shutter APPROVAL DOCUMENT: Drawing No. 02- 868 -111, titled " 22 ga Galvanized' Steel Storm Panels ", sheets 1 through 4 of 4, prepared by Frank L. Bennardo, P.E., dated November 18, 2002, last revision dated January 02, 2003, signed and sealed by Frank L. Bennardo, P.E., bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact LABELING: Each panel shall bear a permanent label with the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami - Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 02- 1120.02 and consists of this page 1, evidence submitted page E -1 as well as approval document mentioned above. The submitted documentation was reviewed by Helmy A. Makar, P.E., M.S. NOA No. 07- 0817.03 Expiration Date: 0 Approval Date: 11/01/2007 00 o //Zoe? Pagel Florida Storm Panels, Inc. • • . • • • • s. es • • • se .. • • • to '• • • • • • • • • • seep • • • • • • • • • • se. • • • • ... NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED • .. • .. . . 1. EVIDENCE SUBMITTED UliDEVg1tFVuttis'API!ROWAL #02- 1120.02 A. DRAWINGS •.. • • • 1. Drawing No. 02- 868 -111, titled " 22 ga Galvanized Steel Storm Panels ", sheets 1 through 4 of 4, prepared by Frank :L Birn4Pdo ;P.E,•n'ated November 18, 2002, last revision dated January 02, 2003:404 cut sea ed by frank L. Bennardo, P.E. B. TESTS 1. Test report on: Uniform Static Air Pressure Test, Large Missile Impact Test and Cyclic Wind Pressure Test prepared by Construction Testing Corporation, Report No. 02 -041, dated November 18, 2002, signed and sealed by Yamil G. Kuri, P.E. 2. Test report on fastener by Construction Testing Corporation, Report No. 02 -007A, dated May 06, 2002, signed and sealed by Yamil G. Kuri, P.E. 3. Test report on Wood Bushings by Construction Testing Corporation, Report No. 02- 038, dated October 07, 2002, signed and sealed by Yamil G. Kuri, P:E. C. CALCULATIONS 1. 22 ga. Galvanized Steel Storm Panels and Anchor Calculations, sheets 1 through 26 of 26, dated November 18, 2002, prepared by Frank L. Bennardo, P.E., signed and sealed by Frank L. Bennardo, P.E. 2. Anchor Calculations, 9 pages, dated November 18, 2002, prepared by Frank L. Bennardo, P.E., signed and sealed by Frank L. Bennardo, P.E. D. MATERIAL CERTIFICATIONS 1. Mill Certified Inspection Report. 2. Certified Tensile Test Report issued by Certified Testing Laboratory, Report Number 1098H, dated October 29, 2002, signed and sealed by Ramesh Patel, P.E. 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. None. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami - Dade County Building Code Compliance Office. E. MATERIAL CERTIFICATIONS 1. None. E -1 // / my A. Makar, P.E., M.S. Product Control Examiner NOA No. 07- 0817.03 Expiration Date: 01/23/2013 Approval Date: 11/01/2007 .pRODUCT.MAq<WG • (LOCATION OPTIONAL) t• ROLL BACK 'I 1312' r _ 1, 4 -20 X 3 41' 5.5. STUD 61 o 0125 1500' L. TYP. ---I MAX 1315' I STORM PANEL 0.,50' 7 r I MIN 0� GENERAL NOTES: 22ga: t =0.025' GALVANIZED ---I 1312' 1 r _ 12.500' PANEL COVERAGE 14.438' PANEL LENGTH 0.125' TYP. --{ 1315' 1.00' MIN. 1 5.000' MAX. 0 STUDDED ANGLE 0 BUILDOUT /CLOSURE ANGLE 1. TI-115 SHUTTER SYSTEM HAS BEEN DESIGNED AND TESTED AS A LARGE MISSILE IMPACT PROTECTIVE SYSTEM IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 2001 AND PROTOCOLS TA5 201 FOR LARGE MISSILE IMPACT, TAS 202 FOR UNIFORM STATIC AIR PRESSURE AND TAS 203 FOR CYCLIC WIND LOADING. 2. NO 33.3% INCREASE IN ALLOWABLE STRESS 1-445 BEEN USED IN TI-4E DESIGN OF THE ANCHOR SPACING TABLES. 3. POSITIVE AND NEGATIVE DESIGN PRESSURES TO BE USED WITH THESE DRAWINGS SHALL BE DETERMINED BY OTHERS ON A JOB - SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. WHEN ASCE 1 -98 15 USED TO CALCULATE PRESSURES FOR USE WITH TI-415 PRODUCT, THE USE OF A DIRECTIONALITY FACTOR Kd =085 15 ALLOWED. 4. THE SHUTTER SYSTEM DETAILED HEREIN IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SPECIFIC SITE. IF SITE CONDITIONS DEVIATE FROM THE CONDITIONS DETAILED HEREIN, A LICENSED ENGINEER OR REGISTERED ARCHITECT 51-IALL PREPARE SITE SPECIFIC DOCUMENTS TO BE USED IN CONJUNCTION WITH THIS DOCUMENT. 5. PERMIT HOLDER SHALL VERIFY TI-4E ADEQUACY OF THE EXISTING STRUCTURE TO WITHSTAND ADDITIONAL IMPOSED LOADS. 6. STORM PANEL'S SHALL BE 22ga STEEL (GALVANIZED THICKNESS t =0.029' MIN) CONFORMING TO ASTM A653, STRUCTURAL QUALITY, GRADE 50. G90 GALV. COATING WITH A MIN. Fy =92.0 K5I. ALL EXTRUSIONS SHALL BE 6063 -T6 ALUMINUM ALLOY, UN.O. 1. PANELS SHALL BE PERMANENTLY LABELED WITH A MINIMUM OF ONE MARKING PER PANEL AS FOLLOWS: FLORIDA STORM PANELS, INC. OPA- LOCKA, FLORIDA MIAMI -DADE COUNTY PROD. CONTROL APPROVED 8. STORM PANELS HAVE BEEN DESIGNED AND TESTED TO THE MAXIMUM SPANS AND LOADS SHOWN ON THESE DRAWINGS. REFERENCE CONSTRUCTION TESTING CORPORATION (CTC), OF MIAMI, FL, TEST REPORT No. 02 -041. 10. TOP 4 BOTTOM DETAILS 51-1O11,N MAY BE INTERCHANGED AS FIELD CONDITIONS DICTATE. PANELS MAY BE MOUNTED HORIZONTALLY WHERE APPLICABLE, EXCEPT FOR MOUNTING CONDITIONS INCLUDING 'H' OR 'U' HEADERS. 11. ALL BOLTS 4 WASHERS SHALL BE ZINC COATED, GALVANIZED OR STAINLESS STEEL WITH A MINIMUM TENSILE STRENGTH OF 60 K51. • • ••• • PRDDUCI•MARRING • • (tCSTI�I. OP:ON� • • • • • ••• • •• • • • • • • • • :000: • 2.062' • . i • • • 1312 ••LI••• • • 0.067' • •• -- 1.161' • • • • "'•'* • • 0 • • • • • I•r• • • • • • • • • i• • • •• • • • ••• • • 0250' 1-1.181'-d • • • • • • • • � ' 4 1 EADER • • • • • • • • • • • • • • • • •• �-•1 I • 1 • F • • • ••• •• 18ga TYP (t = 0.0516' r GALV STEEL, GRADE 50) r 1.00' I 1.00' MIN. 5.000' MAX. O J -PAN CLOSURE 11--1.815* .043' 0.0 3 0.0931 0.015' � B 0 I d? 0.063 0.015' .063' 13 TOP 'H' TRACK 1 4 -20 5$. SIDEWALK OR MACHINE BOLT 1 WASHERED WINGNUT 0 24' O.. TYP. 18 GA. GALV. STEEL BENT PLATE (0.0418' BM. THK) OR 2'x2'x.125' 6063 -T6 ALUM. ANGLE EXISTING CONCRETE. �4 HOLLOW BLOCK OR WOOD FRAMING. BUILD -OUT DISTANCE _I 4' MAX. O CORNER CLOSURE DETAIL 0.062' TYP 025 I r-- 0' -- 0250' 0.055j 0865' WASHERED WINGNUT 1 0 (ZAt 3 ALLOY) 2 .061'- 0 1.935' 0 i { L0.053' 0.063 1.00'i _4-- 0.053' 14 BOTTOM 'H' TRACK EXISTING WINDOW OVERLAP WALL BEYOND WINDOW DISTANCE GREATER THAN OR EQUAL TO IS TIMES BUILD -OUT DISTANCE (2001 FOC SECT. 2413.1.3) ALUM. ANGLE ® OR J -PAN CLOSURE PIECE 0 (SEE DETAILS ABOVE). LEG DIRECTION MAY BE R FASTENER 0 15' O.C. FOR DESIGN LOADS LESS THAN OR EQUAL TO /Yips(' (SEE ANCHOR SCHEDULE FOR ANY ACCEPTABLE ANCHOR). FOR DESIGN LOADS GREATER THAN Slpsr,USE ALUM ANGLE CLOSURE PIECE ONLY WITH ANCHORS 0 10' O.C. O BUILD -OUT MOUNT CLOSURE DETAIL N.T.S. 1 -2:000. 1 - 1.181' - O 'U' HEADER MAX I MAX 2.00' MIN. 3315' MAX.- - 0315 0315' -{ 0.189' % z La m YP 0320• - 0.500' F 7 0.410' 0.550' 1.000' t = 0.015' MIN. KEYHOLE WASHER GALV. STEEL GRADE S0 (USE IS OPTIONAL. REQUIRED ONLY FOR USE WITH TRUSS HEAD ANCHORS 1 CALK -IN) 1.000' 0 w L W 1.000' O BUILD -OUT 'F' TRACK 80.158' I5 TOP 'U' TRACK 025' r MAX. 80301' EXIST. CONC. HOLLOW BLOCK OR WOOD FRAMING. 0150' 0.388' 0.151. cs, TYP. 0 'F' TRACK 4.000' 1.000' r0.125' 0.063' TYP 12 HEADER END CAP L150' DEEP TYPICAL 0.125' f 0.093' 5313' 16 BOTTOM 0.063' --1 0.063' II d. 1 L 0.093' 'U' TRACK 0.093' - 025' \ 0500' OVERLAP MINIMUM EMBED F TRAP MOUNT CLOSURE DETAIL N.T.S. 1.000' E ISTING CONCRETE. HOLLOW BLOCK OR WOOD FRAMING O WALL MOUNT CLOSURE DETAIL N.T.S. 0215' 0.452' 0.655' ALUM. ANGLE ® OR J -PAN CLOSURE PIECE 0 (SEE DETAILS ABOVE). LEG DIRECTION MAY BE REVERSED. FASTENER 0 5' O.G. FOR DESIGN LOADS LESS THAN OR EQUAL TO 8lpsf (SEE ANCHOR SCHEDULE FOR ANY ACCEPTABLE ANCI -IOPJ. FOR DESIGN LOADS GREATER THAN Slper, USE ALUM ANGLE CLOSURE PIECE ONLY WITH ANCHORS 0 10' O.C. TOP MOUNT (CONK TYPE AS REQ'D) BOTTOM MOUNT (CONK TYPE As REQ'D) L TOP MOUNT (CONN ITPC AS REQ'D) WIDTH UNLIMITED (PERP. TO PANEL SPAN) 150' OPTIONAL V 4 -20 STITCH BOLTS WITH WASHERED WINGNUTS FASTENED O OVERLAPS 9 MIDSPAN (USE APPROPRIATE SPAN TABLE) ' PLAN VIEW R03IT a \ 010111 I / , \I O TYPICAL MOUNT ELEVATION N.T.S. BOTTOM I BSTRUCTION I � O _ t BOTTOM MOUNT CONN TYPE AS R.EQ'D) 025' MAX EXISTING CONCRETE, HOLLOW BLOCK OR WOOD FRAMING TYP. SECTIONS LAST PANEL BEFORE OBSTRUCTION TYPICAL PANEL OVERLAP MAY BE AT TOP 1 BOTTOM _ - 0.315' MN. EDGE DIST. PANEL ABOVE OBSTRUCTION TYP. PANEL OVERLAP OPTIONAL 1 4 -20 STITCH BOLTS WITH WASHERED WINGNUTS FASTENED A OVERLAPS ® MIDSPAN (USE APPROPRIATE SPAN TABLE) O TYPICAL MOUNT ELEVATION AROUND OBSTRUCTION B N.T.S. Vi._ { %f `, 07 7- 09 / a o Approved as complyiug with the Florida g £ e 03 Dote 2 Miami Wade Product !C®UtVOt FRANK L. BENNARDO, P.E. 'P50046545 O LL REVISIONS DESCRIPTION DATE CCUNTY C 1'1ENTS 1/1(03 SCALE: 3' = I' DRAWN BY: CL LHELKEL) BY: FLB PRINT DAl O 11/18/02 DWG- °: 02 -868 -111 SHEET: OF 4 Positive Load (pst' Span Less Than: Separation (inches) at <= 30' Separation (inches) at > 30' 10' - 7" 6' - 0" 2.75" 1.22" 30 8' - 8" 2.75" 1.94" 39 ._ 10' - 5" 3.00" 3.00" 9' -8" 6' - 0" 2.75" 1.25" 35 8' - 8" 2.75" 2.10" 50 10' - 0" 3.00" 3.00" 8'- 5" 6' - 0" 2.75" 1.29" 40 8' - 8" 2.75" 2.26" 65 9' - 8" 3.00" 3.00" T - 6" 6' - 0" 2.75" 1.32" 45 8' - 8" 2.75" 2.41" 80 9' - 4" 2.92" 2.92" 50 6' - 0" 2.75" 1.36" 5' - 4" 8' - 10" 2.75" 2.73" 60 6' - 0" 2.75" 1.43" 4' -1" 8' - 1" 2.75" 2.44" 70 6' - 0" 2.75" 1.51" 7' - 6" 2.75 2.24 Load W (psf) No Stitch Bolts LMAx (ft) Stitch Bolts At Midspan LMAx (ft) 25 10' - 7" 10' - 7" 30 10'- 5" 10'- 5" 35 10'- 0" 10'- 0" 39 ._ 9'-_9" 9' -9" 40 9' -8" 9' -8" 45 9' - 4" 9' - 5" 49 8'- 11" 9'- 3" 50 8' - 10" 9' - 2" 55 8'- 5" 8'- 11" 58 8' - 2" 8' - 10" 60 8'- 1" 8'- 9" 65 7 - 9" 8' - 3" 70 T - 6" 7' -8" 72 7' - 4" 7' - 6" 75 7' - 2" 7' - 2" 80 6' - 9" 6' - 9" 90 6'- 0" 6'- 0" 100 5' - 4" 5' - 4" 110 4'- 10" 4'- 10" 120 4'- 6" 4'- 6" 130 4' -1" 4' -1" EXISTING CONCRETE, HOLLOW BLOCK OR WOOD FRAMING (SEE ANCHOR SCHEDULE T3 BASED ON TYPE OF STRUCTURE) ' ` EMBED W F a w REQ'D SEPARATION FROM GLASS (REF. TABLE T2) EXISTING GLAZING *14 TEK SCREW OR 1 4 -20 MACHINE SCREW d NUT 6 16* O.C. (TYP ALL SIM. CONNECTIONS w0 CI CONNECTION TYPE ANCHORS TO BE AT 12.5' OR 625' O.C. (REFERENCE ANCHOR SCHEDULE T3 FOR MAX SPACING). USE REMOVABLE ANCHORS ONLY EXISTING CONCRETE, HOLLOW BLOCK OR WOOD FRAMING. SEE ANCHOR SCHED. BASED ON TYPE OF STRUCTURE REQ'D SEPARATION FROM GLASS (REF. TABLE T2) C3 CONNECTION TYPE, REFERENCE ANCIaOR SCHEDULE T3 FOR MAX SPACING SHORT LEG MAY BE REVERSED TOWARDS THE OPENING • • 0.500' Ea • • • • • • Ea ' • • • • • ri 0.500' C2 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE T3 FOR MAX SPACING G BUILD - OUT MOUNT SECTION N.T.S. 'tea -20 x 3 4' 5.5. MACHINE SCREWS 6 12.5' O.G. C2 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE T3 FOR MAX SPACING 'F' TRACK/DIRECT MOUNT SECTION N.T.S. } • • •• •• • • • • • • • • •• • • • • J W J a_ 0 111 1- W W W N % Z 1 I/4 -20 X MACH NE SCREW ® 125' O.C. astwittibe om • w, m122, oo ;.r.44-ztjar 13 tict EXISTING- CONCRETE. HOLLOW BLOCK OR WOOD FRAMING. SEE ANCHOR SCHED. BASED ON TYPE OF STRUCTURE. ••• • • • • • • • • • • • ■ ••• • • • • ••• 02 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE T3 FOR MA* SPACING • • • • 0 a Ea • • • • • ••• • • • • • • • •s •• ••• ANGLE • IAAi• • • lD,• • C2 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE T3 FOR MAX.. SPACING • OPTIONAL BUILDOUT MOUNTING CONFIGURATIONS (AT HEADER OR SILL) EXISTING CONCRETE. HOLLOW BLOCK OR WOOD FRAMING. SEE ANCHOR 5CHED.BASED TYPE OF STRUCTURE • • ••• •• •• • • • • • • • • • • 0 REa'D r.LASs SEPAR DIST. (SEE TABLE T2 FOR MIN) } 0 w o EXISTING GLAZING MI EMBED. EMBED. WALL MOUNT SECTION N.TS. EXISTING CONCRETE. HOLLOW BLOCK OR WOOD FRAMING. SEE ANCHOR SCI-IED. BASED ON TYPE OF STRUCTURE. EXISTING CONCRETE. HOLLOW BLOCK OR WOOD FRAMING-. • SEE: •'SCHEDJBs45ED ON TYPE OF STRUCTURE. C3 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE T3 FOR MAX. SPACING 10500' 0250' 025' '4-20 X 3 4' 5.5. MACHINE SCREW W/ WINGNUT 6125' O.C. G2 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE T3 FOR MAX SPACING MA 0 EMBED REQ'D SEPARATION FROM GLASS (REF. TABLE T2) s- IiiteW"Airdr wor lo 1 4-20 x 3 4' 5.5 MACHINE SCREWS 6 12.5' O.C. LEG DIR. MAY BE REVERSED EXISTING • GLAZING fe Ala ••� 025' 0 AX 025' r 1 MAX O CEILING/FLOOR MOUNT SECTION N.T.S. 04 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE T3 FOR MAX. SPACING t t a 04 CONNECTION TYKE REFERENCE ANCHOR SCHEDULE T3 FOR MAX SPACING MAXIMUM ALLOWABLE SPAN SCI- 1EDULE NOTES: I. ENTER SPAN SCHEDULE WITH NEGATIVE DESIGN LOAD TO DETERMINE MAXIMUM ALLOWABLE STORM PANEL SPAN. SCHEDULE 15 ACCEPTABLE FOR USE WITH POSITIVE LOADS LESS THAN OR EQUAL TO NEGATIVE DESIGN LOADS. 2. INTERPOLATION BETWEEN LOADS I5 ACCEPTABLE, OTHERWISE USE NEXT NIGHER LOAD. EXISTING GLAZING REQ'D SEPARATION FROM GLASS (REF. TABLE T2) O K TRUSS MOUNT SECTION N.T.5 EXISTING CONCRETE. I- IOLLOW BLOCK OR WOOD FRAMING. SEE ANCHOR SCHED. BASED ON TYPE OF STRUCTURE. EXISTING WOOD TRUSSES fl 24' O.C. MAX EXISTING GLAZING O OFFSET WALL MOUNT SECTION NTS. MINIMUM SEPARATION 0 TABLE T2 NOTES: I. ENTER SPAN SCHEDULE WITH POSITIVE DESIGN LOAD TO DETERMINE MINIMUM ALLOWABLE STORM PANEL SEPARATION FROM GLASS OR DOOR TO BE PROTECTED. SCHEDULE 15 REQUIRED FOR USE WITH POSITIVE LOADS ONLY. 2. INTERPOLATION BETWEEN LOADS IS ACCEPTABLE, OTHERWISE USE NEXT NIGHER LOAD. EXTERIOR WALL FINISH STEEL TUBE TO BOTTOM TRUSS CHORDS W/ (3) 1 '4'x2' EMBED LAG SCREWS a EACH TRUSS (24' O.C. MAX) 4'x MIN STEEL TUBE 'U' HEADER TO ROLLED STEEL TUBE W/ CENTER LAG (AS DESCRIBED ABOVE) g TRUSSES 4"14 SP1.S TO PLATE 6 6' O.C. BETWEEN TRUSSES Lmax = S' -0' (MAX SPAN) MAX DESIGN LOAD = 160 psI ALUM OR GALV STEEL SPACER, AS RECD. EXTERIOR WALL FINISH, PROTRUDING FROM MOUNTING SURFACE CI CONNECTION TYPE ANCHORS TO BE AT 12.5' OR 625' 0C. (REFERENCE ANCHOR SCHEDULE T3 FOR MAX. SPACING) USE REMOVABLE ANCHOR5 ONLY FRANK L. SENNA 'PE0046545 z (f) ^ ti) - LL Z �. Z>c(= Z -L 0 0_ 0 REVISIONS DESCRIPTION COUNTY CR"p7E'Rs SCALE: 3 = DRAWN BY: CL C= HOCKED BY: FLB 1- 121Nf DATE: 1/15/02 DWG ': 02 -56S -III SHEET: 2 OF 4 0 z W W Z Z W iD L 9 3 DATE 1/)/03 EXISTING GLAZING PENETRATION OR EMBED. w ��— 4A101mml o 41 iecn vVM MvNIa:I EXISTING GLAZING EXISTING CONCRETE, HOLLOW BLOCK OR WOOD FRAMING. SEE ANCHOR SCHED. BASED ON TYPE OF STRUCTURE WALL MOUNT SECTION WALL MOUNT TRACKS, N.T.5. REQ'D GLASS SEP_ DIST. (SEE TABLE — T2 FOR MINIMUM) A EXISTING CONCRETE. HOLLOW BLOCK OR WOOD FRAMING. SEE ANCHOR SCHED. BASED ON TYPE OF STRUCTURE. 1365' 1365' REQ'D GLASS SEP. DIST. (SEE TABLE T2 FOR MINIMUM) 1365' G$ CONN TYPE REF. ANCHOR SCHED. T4 FOR MAX. SPACING Cl CONN TYPE REF. ANCHOR SCHED. T4 FOR MAX SPACING O HEADER /SILL MOUNT SECTION TRAP MOUNT TRACKS ON ANGLE, N.T. EXISTING CONCRETE. • HOLLOW BLOCK OR WOOD FRAMING. SEE, • ANCHOR SCHED. BASED • ON TYPE OF STRUCTIIRE • CB CONNECTION TYPE REFERENCE ANCHOR SCHEDULE T4 FOR • s MAX. SPACINI ♦ • • e • 0.500' _• • • • a • • • • • X w! E• •• • • • • 0.5 C6 CONNECTION TYPE REFERENCE ANCI -IOR SCHEDULE T4 FOR MAX SPACING. LEG MAY BE BENT TO 30dee MAX X a r LEG MAY BE BENT TO 30deg MAX 1•• • • ••• • • EXIST NG GLAZING ••. (79T••. INTERIOR i . • • : • X:STING CONCRETE. HOLLOW BLOCK OR WOOD FRAMING. • • • • 46E6 ANC 1414ED. BASED ON TYPE OF STRUCTURE. f AIP • • • • • • • • 0 • ••• •• 0.50' MAX R. GLASS SEP. DIST. (SEE TABLE T2 FOR MINIMUM) O o _114 67 CEILING/FLOOR MOUNT SECTION TRAP MOUNT TRACKS. N.T.5. LIJ wn REQ'D GLASS 5EP. DIST. (SEE TABLE T2 FOR MINIMUM) EXISTING CONCRETE, HOLLOW BLOCK OR WOOD FRAMING. SEE ANCHOR SCHED. BASED ON TYPE OF STRUCTURE PENETRATION OR EMBED. O DIRECT WALL MOUNT SECTION P BOTTOM DIRECT WALL MOUNT (REF. DETAIL '5'). N.T. 0.500' EMBED. � � 1 ! I1p111111P11111w,vm111 11111 \III' I� • EXISTING GLAZING C1 CONNECTION TYPE REFERENCE ANCHOR 5C4EDULE T4 FOR MAX SPACING Cl CONNECTION TYPE REFERENCE ANCHOR SCHEDULE T4 FOR MAX. - SPACING EXISTING CONCRETE. HOLLOW BLOCK OR WOOD FRAMING. SEE ANCHOR SCHED. BASED ON TYPE OF STRUCTURE. G5 CONNECTION TYPE REFERENCE ANCHOR SCHEDULE T4 FOR MAX SPACING {{{ ��� 1.00 ` MAX LNT INSTALLATION DETAILS OPTION A: (3) 1 4' ELCO PANELMATES AT BOTTOM OF ADJACENT PANEL FASTEN EACH PANEL ADJACENT TO LAST PANEL e BOTTOM W/ (2) ELCO ° ANELMATES (I) POWERS CALK -IN. ALTERNATIVELY, USE (3) PANELMATES AND NOTCH BOTTOM COMERS OF LAST PANEL TO FIT OVER INNERMOST ANCHORS. O Q HEADER TRACK ISOMETRIC TOP TRACK, N.T.5. CLIP LOCKS END PANEL FLUSH AGAINST TOP TRACK (1) HEADER END CAP e END W/ (2)'14 5M5 TO TRACK ADJACENT PANEL TYP 12.5' • COVERAGE 1'x030' PERFORATIONS AT MIDSPAN FOR USE WITH REMOVABLE HANDLE AND /OR PLASTIC KNOBS (2) 11 4 -20 SS. STITCH BOLTS W/ WINGNUTS EACH SIDE OF LAST PANEL I 'H'- HEADER a TOP, PER DETAIL 'P' OPT. A: 252' MAX NOTCH IN LAST PANEL AROUND WINGNUT O DIRECT WALL MOUNT EXTERIOR ELEVATION BOTTOM DIRECT UTAt I MOUNT (REF. DETAIL 'P), N.T. LAST PANEL MOUNTED FROM INSIDE OF BLDG ADJACENT Eterestejo TYPICAL OVERLAP OPTIONAL PLASTIC KNOB, TO EASE PANEL SLIDING (NON - STRUCTURAL, SEE DETAIL TO LEFT) O SILL TRACK ISOMETRIC BOTTOM TRACK, N.T.5. Approved as co p ylag sr s at ?Florida C e c�o3 Date 2 NOM Miami Dade Prodeet Division E N I PANEL 4iW °+ &' i AIWA t 0 .tAr iaz= o7 - o 9/ 7.03 —fl 'A.2 OPTION B: (2) 1 4' ELCO PANELMATES AT BOTTOM OF ADJACENT PANELS OPT. B: (1) 1 '4 - POWERS CALK -IN, CLOSEST TO LAST PANEL (NO NOTCH REQ'D) (I) I'x2'x0.092'xI ANGLE a END W/ (2) '14 5M5 TO TRACK TOP 'H' -TRACK OR TOP 'U' -TRACK (FASTEN TO STRUCTURE PER SECTIONS TO LEFT) BOTTOM 'H' TRACK OR BOTTOM 'U' TRACK (FASTEN TO STRUCTURE PER DETAILS M, N aO TO LEFT) FRANK L. BE `PE0046549 0 REVISIONS DESCRIPTION COUNTY COMMENTS SHEET: 3 OF 4 00 o U Z _Z w v z w W Z Z1 W u 3 in DATE 1/)/03 SCALE: 3 _ ' (UN.O.) DRAWN BY: CL C,HECKEL) BY: FLB PRIN r DATE: 11/18/02 DWG 0 : 02 -868- 1 1 HOLLOW CONC BLOCK 1/4" x1-1/4" EMBED ELCO TAPCON . 39 45 55 65 72 39 49 58 12.5" 12.5" 12.5" 16.0" 16.0" 16.0" 16.0" 12.7" 8.7" 15.8" 12.5" 10.5" 12.5" 6.25" 6.25" 15.5" 12.3" 10.4" 7.8" 5.2" 4.0" 9.9" 7.7" 6.5" 12.5" 6.25" 6.25" 12.6" 10.0" 9.7" 5.4" 3.8" 3.6" 7.9" 6.2" 6.0" Tcap (Ib) = 218.00 9.0" 72 12.5" 13.2" 5.9" 8.3" 6.25" 9.7" 3.6" 6.0" 6.25" 9.7" 3.6" 6.0" Vcap (Ib) = 398.00 65 130 6.25" 9.7" 3.6" 6.0" 6.25" 9.7" 3.6" 6.0" 6.25" 9.7" 3.6" 6.0" 114 "x7 /8" EMBED 16.0" 39 12.5" 16.0" 16.0" 16.0" 12.5" 16.0" 12.7" 10.3" 12.5" 16.0" 8.8" 8.3" ALL - POINTS SOLID -SET 16.0" 49 12.5" 16.0" 16.0" 13.1" 12.5" 16.0" 8.5" 8.2" 12.5" 16.0" 6.2" 6.6" LEAD SHIELD ANCHOR * 58 12.5" 16.0" 14.3" 11.0" 12.5" 16.0" 6.6" 6.9" 12.5" 15.9" 5.9" 6.4" Tcap (Ib)= 358 10.6" 72 12.5" 16.0" 9.6" 8.8" 12.5" 15.9" 5.9" 6.4" 12.5" 15.9" 5.9" 6.4" Vcap (Ib) = 249 58 130 12.5" 15.9" 5.9" 6.4" 12.5" 15.9" 5.9" 6.4" 12.5" 15.9" 5.9" 6.4" 1/4" x 1 -1/4" EMBED 12.7" 12.5" 16.0" 7.1" 9.2" 39 12.5" 16.0" 16.0" 12.2" 12.5" 14.5" 7.3" 7.7" 6.25" 11.8" 5.1" 6.2" ELCO PANELMATE 9.2" 49 12.5" 16.0" 11.9" 9.7" 6.25" 11.6" 4.9" 6.0" 6.25" 9.4" 3.6" 4.9" 49 * 58 12.5" 15.4" 8.2" 8.1" 6.25" 9.8" 3.8" 5.1" 6.25" 9.1" 3.4" 4.7" Tcap (Ib) = 204.75 12.5" 72 6.25" 12.4" 5.5" 6.5" 6.25" 9.1" 3.4" 4.7" 6.25" 9.1" 3.4" 4.7" Vcap (Ib) = 233.50 Vcap (Ib) = 565.00 130 6.25" 9.1" 3.4" 4.7" 6.25" 9.1" 3.4" 4.7" 6.25" 9.1" 3.4" 4.7" HOLLOW CONC BLOCK 1/4" x 1 -1/4" EMBED ELCO TAPCON Tcap (Ib) = 218.00 Vcap (Ib) = 398.00 39 45 55 65 72 39 45 55 65 72 16.0" 16.0" 11.0" 6.4" 5.0" 16.0" 16.0" 16.0" 14.6" 13.2" 7.5" 5.2" 3.4" 15.5" 13.4" 11.0" 9.7" 9.7" j 1/4 "x7 /8" EMBED 12.3" 39 16.0" 16.0" 12.4" 16.0" ALL- POINTS SOLID -SET 9.0" 45 16.0" 16.0" 8.5" 16.0" LEAD SHIELD ANCHOR * 55 16.0" 16.0" 5.5" 16.0" Tcap (Ib) = 358 Vcap (Ib) = 249 65 10.5" 16.0" 4.4" 15.9" Vcap (Ib) = 249 39 72 8.2" 16.0" 4.4" 15.9" 1/4" x 1 -1/4" EMBED 9.7" 39 16.0" 16.0" 7.1" 14.5" ELCO PANELMATE 5.6" 45 16.0" 16.0" 4.8" 12.6" 4.8" * 55 10.3" 16.0" 3.2" 10.3" Tcap (Ib) = 204.75 3.2" 65 6.0" 13.7" 8.0" 9.1" Vcap (Ib) = 233.50 10.3" 72 4.7" 12.4" A 9.1" HOLLOW CONC BLOCK 1/4" x 1 - 1/4" EMBED ELCO TAPCON Tcap (lb) = 174.00 Vcap (Ib) = 318.00 39 45 55 65 72 12.6" 10.9" 8.9" 7.5" 6.8" 8.2" 7.1" 5.8" 4.9" 4.5" 8.0" 6.9" 5.7" 5.0" 5.0" 5.2" 4.5" 3.7" 3.3" 3.3" 114 "x7/8" EMBED 39 16.0" 12.3" 10.4" 7.8" ALL - POINTS SOLID -SET 45 14.2" 10.7" 9.0" 6.8" LEAD SHIELD ANCHOR * 55 11.7" 8.7" 7.4" 5.5" Tcap (Ib) = 358 65 9.9" 7.4" 6.5" 4.9" Vcap (Ib) = 249 72 8.9" 6.7" 6.5" 4.9" 1/4" x 1 -1/4" EMBED 39 11.2" 8.0" 7.1" 5.1" ELCO PANELMATE 45 9.7" 6.9" 6.2" 4.4" * 55 7.9" 5.6" 5.0" 3.6" Tcap (Ib) = 201.50 65 6.7" 4.8" 4.4" 3.2" Vcap (Ib) = 198.50 72 6.1" 4.3" 4.4" 3.2" ANCHOR SPACING SCHEDULE • • ••• • • • ••• .• •• • • • • •• .• • • • • • • • • • • • • ANCHOR NOTES_ • • ••• • • • 1. SPANS AND LOADS SHOWN HERE ARE FOR DETERMINING ANCHOR SPACING ONLY ALLOWABLE STORM PANEL SPANS FOR SPECIFIC LOADS MUST BE LIMITED TO THOSE 51-1OWN IN MAX ALLOWABLE SPAN SCHEDULE (TABLE 2. ENTER ANCHOR SCHEDULE BASED ON THE EXISTING STRUCTURE MATERIAL 4 ANCHOR TYPE. SELECT DESIGN LOAD GREATER THAN OR EQUAL TO NEGATIVE DESIGN LOAD ON SHUTTER AND SELECT SPAN GREATER THAN OR EQUAL TO SHUTTER SPAN. 3. SELECT CONNECTION TYPE BASED ON APPROPRIATE MOUNTING CONDITION (SEE MOUNTING DETAILS ON SHEETS 2 4 3 FOR IDENTIFICATION OF CONNECTION TYPE). 4. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. 5. WHERE EXISTING STRUCTURE 15 WOOD FRAMING, EXISTING CONDITIONS MAY VARY. FIELD VERIFY THAT FASTENERS ARE INTO ADEQUATE WOOD FRAMING MEMBERS, NOT PLYWOOD. FASTENING TO PLYWOOD 15 ACCEPTABLE ONLY FOR SIDE CLOSURE PIECES. ANCHOR SPACING SCHEDULE • T4 C- I NS! DE"MOUNT-PANEL'S; °WALL MOUNT) 0 0 39 PENETR. LAG SCREW 45 55 Tcap (Ib) = 359.53 65 Vcap (Ib) = 82.97 72 1/4" x 2" THREAD #14 x 1 -1/2" THREAD 39 PENETR. WOOD SCREW 45 55 Tcap (Ib) = 234.00 65 Vcap (Ib) = 96.74 72 7/16" x 5/8" EMBED BRASS BUSHING & 1/4-20 SCREW Tcap (lb) = 231.50 Vcap (Ib) = 232.50 39 45 * 55 65 72 16.0" 16.0" 16.0" 10.6" 8.2" 0.75" EDGE DISTANCE 16.0" 16.0" 16.0" 16.0" 16.0" 12.4" 8.5" 5.6" 4.4" 4.4" 16.0" 16.0" 16.0" 16.0" 16.0" 16.0 16.0" 11.8" 6.9" 5.3" 16.0" 16.0" 11.7' 6.8" 5.3" 16.0" 16.0" 16.0" 15.7" 14.2" 16.0" 16.0" 16.0" 15.5" 14.0" 8.1" 5.5" 3.6" 8.0" 5.5" 3.6" 16.0" 14.4" 11.8" 10.4" 10.4" 16.0" 14.2" 11.7" 10.3" 10.3" ANCHOR SPACINGS SCHEDULE 'f INSIDE "MOUNT PANELS, TRAP MOUNT) 0 0 114" x 2" THREAD 39 PENETR. LAG SCREW 45 55 Tcap (Ib) = 359.53 65 Vcap (Ib) = 82.97 72 #14 x 1 -1/2" THREAD 39 PENETR. WOOD SCREW 45 55 Tcap (Ib) = 234.00 65 Vcap (Ib) = 96.74 72 7/16" x 5/8" EMBED BRASS BUSHING & 1/4 -20 SCREW Tcap (lb) = 231.50 Vcap (Ib) = 232.50 39 45 * 55 65 72 0.75" EDGE DISTANCE 7.5" 6.5" 5.3" 4.5" 4.1" 6.5" 57" 4.6" 3.9" 3.5" 7.7" 6.6" 5.4" 4.6" 4.1" 6.2" 5.4" 4.4" 3.7" 3.3" 13.0" 11.2" 9.2" 7.8" 7.0" 9.2" 8.0" 6.5" 5.5" 5.0" 4.8" 4.2" 4.1" 3.6" 3.4" 4. 4. 3. 3. 3. 9" 3.9" 2" 3.4" 4" j 0" 8.2" 7.1" 5.8" 5.1" 5.1" 5.8" 5.1" 4.1" 3.7" 3.7" WHERE LAG SCREWS FASTEN TO NARROW FACE OF STUD FRAMING, FASTENER 51-IALL BE LOCATED IN CENTER OF NOMINAL 2' X 4' (MIN.) WOOD STUD ( EDGE DISTANCE 15 ACCEPTABLE FOR WOOD FRAMING). WOOD STUD SHALL BE 'SOUTHERN PINE' G =055 OR GREATER DENSITY. LAG SCREW SHALL HAVE PHILLIPS PAN HEAD OR HEX HEAD. -. * DESIGNATES REMOVABLE ANCHORS, WHICH ARE REQUIRED FOR DIRECT MOUNT INSTALLATIONS. 8. MACHINE SCREWS 51-IALL HAVE MINIMUM OF '� ENGAGEMENT OF THREADS IN BASE ANCHOR AND MAY HAVE EITHER A PAN HEAD, TRUSS HEAD, OR WAFER HEAD (SIDEWALK BOLT) UN.O. ZEOULTEaniao '3. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDES STUCCO OR OTHER WALL FINISHES. Its I0. DESIGNATES ANCHOR CONDITIONS WHICH ARE NOT ACCEPTABLE FOR USE. 1 74 8 2 Z•lit22- 0 Approved tpl, 8aig with tke !Florida svi 23 o PJ ®401 0 � i I'1-o • 0 2. Miami Dade Frodua Coaf9a l FRANK L. BENNARDO. P.E. 'PE0046549 , (71 d 9 m = ril <n = IL (n X 0 4 . 4 CO F m (V N 0 Q Fri • 0 tt dl 0 l7 W W z W IL 3 3 U crc z J z 1 0_ 0 (0 1 t!L 0 J IL;L W -t z W cc I r S • 4 CV j Z D� I 0 COUNTY CO'1ENTS SHEET: 4 OF 4 03 REVISIONS DESCRIPTION DATE VI /03 SCALE: N.T.S. DRAWN BY: CL CHEGK.ED BY: FLB PRIN f DA rE: 41/18/0 DWG "o D2- 868 -III 0.G frazt`'..a EMAIL: FIRANK6FLBENGINEERING.COM 2.0" EDGE DISTANCE EXIST. STRUCT. ANCHOR LOAD (psf) z " M4DISIANct . :. SPANS UP TO 8.67 ft CONN TYPE C7 C8 CONCRETE 1/4" x 1 -3/4" EMBED !EXIST. STRUCT. ANCHOR 15.3" LOAD (psf) SPANS TO C1 UP 5.50 CONN TYPE it ••• t4s SPANS UP TO 8.67 ft • ••• COIN TAt • SPANS TO • : GI UP 10.67 TYPE ft C4 C2 C3 :C4 C2. . • CS C2 C3 I CONCRETE 1/4" x 1 -3/4" EMBED 65 39 12.5" 16.0" 16.0" 18sO T " 1670i 1&0 16.154 11.6" 16.0" 11.9" 13.5" ELCO TAPCON 39 49 12.5" 16.0" 16.0" 16.0" 12.5" 16.0" 11.6" 13.3" 12.5" 16.0" 8.4" 10.7" (MIN 3320 PSI CONC) LEAD SHIELD ANCHOR * 58 12.5" 16.0" 16.0" 16.0" 12.5" 16.0" 8.9" 11.1" 12.5" 16.0" 8.0" 10.3" Tcap (lb) = 483.00 6.7" 72 12.5" 16.0" 13.0 "• 14.3''f2. :" :16•Q: $0l le.3" .'x`25" 46.0" 8.0" 10.3" Vcap (Ib) = 475.00 • 10.3" 130 12.5" 16.0" 8.0" 10.3" '42..x'";1 $Q'' =0.3" 1 16.0" 8.0" 10.3" 114 "x7/8" EMBED 8.2" 39 12.5" 16.0" 16.0" 16.0." 1T2.C" :16'r 1 :2 354)" •1v5" 16.0" 10.6" 12.1" ALL- POINTS SOLID -SET 8.8" 49 12.5" 16.0" 16.0" 16.0" 12.5" 16.0" 10.2" 11.8" 12.5" 16.0" 7.5" 9.5" LEAD SHIELD ANCHOR * 58 12.5" 16.0" 16.0" 16.0" 12.5" 16.0" 7.9" 9.9" 12.5" 16.0" 7.1" 9.2" Tcap (Ib) = 428 12.5" 72 12.5" 16.0" 11.5" 12.7" 12.5" 16.0" 7.1" 9.2" 12.5" 16.0" 7.1" 9.2" Vcap (Ib) = 429 130 12.5" 16.0" 7.1" 9.2" 12.5" 16.0" 7.1" 9.2" 12.5" 16.0" 7.1" 9.2" 114" x 2" EMBED 3.9" 39 12.5" 16.0" 16.0" 16.0" 12.5" 16.0" 13.3" 15.7" 12.5" 16.0" 9.2" 12.6" ELCO PANELMATE 12.5" 49 12.5" 16.0" 16.0" 16.0" 12.5" 16.0" 8.9" 12.4" 12.5" 16.0" 6.5" 9.9" (MIN 3350 PSI CONC) * 58 12.5" 16.0" 14.9" 16.0" 12.5" 16.0" 6.9" 10.4" 12.5" 16.0" 6.2" 9.6" Tcap (lb) = 372.00 8.7" 72 12.5" 16.0" 10.0" 13.3" 12.5" 16.0" 6.2" 9.6" 12.5" 16.0" 6.2" 9.6" Vcap (Ib) = 565.00 14.0" 130 12.5" 16.0" 6.2" 9.6" 12.5" 16.0" 6.2" 9.6" 12.5" 16.0" 6.2" 9.6" ANCHOR SPACING SCHEDULE • • ••• • • • ••• .• •• • • • • •• .• • • • • • • • • • • • • ANCHOR NOTES_ • • ••• • • • 1. SPANS AND LOADS SHOWN HERE ARE FOR DETERMINING ANCHOR SPACING ONLY ALLOWABLE STORM PANEL SPANS FOR SPECIFIC LOADS MUST BE LIMITED TO THOSE 51-1OWN IN MAX ALLOWABLE SPAN SCHEDULE (TABLE 2. ENTER ANCHOR SCHEDULE BASED ON THE EXISTING STRUCTURE MATERIAL 4 ANCHOR TYPE. SELECT DESIGN LOAD GREATER THAN OR EQUAL TO NEGATIVE DESIGN LOAD ON SHUTTER AND SELECT SPAN GREATER THAN OR EQUAL TO SHUTTER SPAN. 3. SELECT CONNECTION TYPE BASED ON APPROPRIATE MOUNTING CONDITION (SEE MOUNTING DETAILS ON SHEETS 2 4 3 FOR IDENTIFICATION OF CONNECTION TYPE). 4. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. 5. WHERE EXISTING STRUCTURE 15 WOOD FRAMING, EXISTING CONDITIONS MAY VARY. FIELD VERIFY THAT FASTENERS ARE INTO ADEQUATE WOOD FRAMING MEMBERS, NOT PLYWOOD. FASTENING TO PLYWOOD 15 ACCEPTABLE ONLY FOR SIDE CLOSURE PIECES. ANCHOR SPACING SCHEDULE • T4 C- I NS! DE"MOUNT-PANEL'S; °WALL MOUNT) 0 0 39 PENETR. LAG SCREW 45 55 Tcap (Ib) = 359.53 65 Vcap (Ib) = 82.97 72 1/4" x 2" THREAD #14 x 1 -1/2" THREAD 39 PENETR. WOOD SCREW 45 55 Tcap (Ib) = 234.00 65 Vcap (Ib) = 96.74 72 7/16" x 5/8" EMBED BRASS BUSHING & 1/4-20 SCREW Tcap (lb) = 231.50 Vcap (Ib) = 232.50 39 45 * 55 65 72 16.0" 16.0" 16.0" 10.6" 8.2" 0.75" EDGE DISTANCE 16.0" 16.0" 16.0" 16.0" 16.0" 12.4" 8.5" 5.6" 4.4" 4.4" 16.0" 16.0" 16.0" 16.0" 16.0" 16.0 16.0" 11.8" 6.9" 5.3" 16.0" 16.0" 11.7' 6.8" 5.3" 16.0" 16.0" 16.0" 15.7" 14.2" 16.0" 16.0" 16.0" 15.5" 14.0" 8.1" 5.5" 3.6" 8.0" 5.5" 3.6" 16.0" 14.4" 11.8" 10.4" 10.4" 16.0" 14.2" 11.7" 10.3" 10.3" ANCHOR SPACINGS SCHEDULE 'f INSIDE "MOUNT PANELS, TRAP MOUNT) 0 0 114" x 2" THREAD 39 PENETR. LAG SCREW 45 55 Tcap (Ib) = 359.53 65 Vcap (Ib) = 82.97 72 #14 x 1 -1/2" THREAD 39 PENETR. WOOD SCREW 45 55 Tcap (Ib) = 234.00 65 Vcap (Ib) = 96.74 72 7/16" x 5/8" EMBED BRASS BUSHING & 1/4 -20 SCREW Tcap (lb) = 231.50 Vcap (Ib) = 232.50 39 45 * 55 65 72 0.75" EDGE DISTANCE 7.5" 6.5" 5.3" 4.5" 4.1" 6.5" 57" 4.6" 3.9" 3.5" 7.7" 6.6" 5.4" 4.6" 4.1" 6.2" 5.4" 4.4" 3.7" 3.3" 13.0" 11.2" 9.2" 7.8" 7.0" 9.2" 8.0" 6.5" 5.5" 5.0" 4.8" 4.2" 4.1" 3.6" 3.4" 4. 4. 3. 3. 3. 9" 3.9" 2" 3.4" 4" j 0" 8.2" 7.1" 5.8" 5.1" 5.1" 5.8" 5.1" 4.1" 3.7" 3.7" WHERE LAG SCREWS FASTEN TO NARROW FACE OF STUD FRAMING, FASTENER 51-IALL BE LOCATED IN CENTER OF NOMINAL 2' X 4' (MIN.) WOOD STUD ( EDGE DISTANCE 15 ACCEPTABLE FOR WOOD FRAMING). WOOD STUD SHALL BE 'SOUTHERN PINE' G =055 OR GREATER DENSITY. LAG SCREW SHALL HAVE PHILLIPS PAN HEAD OR HEX HEAD. -. * DESIGNATES REMOVABLE ANCHORS, WHICH ARE REQUIRED FOR DIRECT MOUNT INSTALLATIONS. 8. MACHINE SCREWS 51-IALL HAVE MINIMUM OF '� ENGAGEMENT OF THREADS IN BASE ANCHOR AND MAY HAVE EITHER A PAN HEAD, TRUSS HEAD, OR WAFER HEAD (SIDEWALK BOLT) UN.O. ZEOULTEaniao '3. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDES STUCCO OR OTHER WALL FINISHES. Its I0. DESIGNATES ANCHOR CONDITIONS WHICH ARE NOT ACCEPTABLE FOR USE. 1 74 8 2 Z•lit22- 0 Approved tpl, 8aig with tke !Florida svi 23 o PJ ®401 0 � i I'1-o • 0 2. Miami Dade Frodua Coaf9a l FRANK L. BENNARDO. P.E. 'PE0046549 , (71 d 9 m = ril <n = IL (n X 0 4 . 4 CO F m (V N 0 Q Fri • 0 tt dl 0 l7 W W z W IL 3 3 U crc z J z 1 0_ 0 (0 1 t!L 0 J IL;L W -t z W cc I r S • 4 CV j Z D� I 0 COUNTY CO'1ENTS SHEET: 4 OF 4 03 REVISIONS DESCRIPTION DATE VI /03 SCALE: N.T.S. DRAWN BY: CL CHEGK.ED BY: FLB PRIN f DA rE: 41/18/0 DWG "o D2- 868 -III 0.G frazt`'..a EMAIL: FIRANK6FLBENGINEERING.COM 2.0" EDGE DISTANCE EXIST. STRUCT. ANCHOR LOAD (psf) SPANS UP TO 5.50 ft CONN TYPE C7 C8 SPANS UP TO 8.67 ft CONN TYPE C7 C8 CONCRETE 1/4" x 1 -3/4" EMBED 39 16.0" 15.3" 13.6" 9.7" ELCO TAPCON 45 16.0" 13.2" 11.8" 8.4" (MIN 3320 PSI CONC) 55 15.2" 10.8" 9.6" 6.9" Tcap (Ib) = 386.40 65 12.9" 9.2" 8.5" 6.0" Vcap (Ib) = 380.00 72 11.6" 8.3" 8.5" 6.0" 1/4 "x7 /8" EMBED 39 16.0" 16.0" 15.2" 10.8" ALL - POINTS SOLID -SET 45 16.0" 14.7" 13.2" 9.3" LEAD SHIELD ANCHOR * 55 16.0" 12.0" 10.8" 7.6" Tcap (lb) = 428 65 14.4" 10.2" 9.5" 6.7" Vcap (Ib) = 429 72 13.0" 9.2" 9.5" 6.7" 1/4" x 2" EMBED 39 16.0" 11.6" 10.3" 7.4" ELCO PANELMATE 45 14.1" 10.1" 8.9" 6.4" (MIN 3350 PSI CONC) * 55 11.5" 8.2" 7.3" 5.2" Tcap (IN = 297.60 65 9.7" 7.0" 6.4" 4.6" Vcap (Ib) = 282.50 72 8.8" 6.3" 6.4" 4.6" ANCHOR SPACING SCHEDULE • • ••• • • • ••• .• •• • • • • •• .• • • • • • • • • • • • • ANCHOR NOTES_ • • ••• • • • 1. SPANS AND LOADS SHOWN HERE ARE FOR DETERMINING ANCHOR SPACING ONLY ALLOWABLE STORM PANEL SPANS FOR SPECIFIC LOADS MUST BE LIMITED TO THOSE 51-1OWN IN MAX ALLOWABLE SPAN SCHEDULE (TABLE 2. ENTER ANCHOR SCHEDULE BASED ON THE EXISTING STRUCTURE MATERIAL 4 ANCHOR TYPE. SELECT DESIGN LOAD GREATER THAN OR EQUAL TO NEGATIVE DESIGN LOAD ON SHUTTER AND SELECT SPAN GREATER THAN OR EQUAL TO SHUTTER SPAN. 3. SELECT CONNECTION TYPE BASED ON APPROPRIATE MOUNTING CONDITION (SEE MOUNTING DETAILS ON SHEETS 2 4 3 FOR IDENTIFICATION OF CONNECTION TYPE). 4. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. 5. WHERE EXISTING STRUCTURE 15 WOOD FRAMING, EXISTING CONDITIONS MAY VARY. FIELD VERIFY THAT FASTENERS ARE INTO ADEQUATE WOOD FRAMING MEMBERS, NOT PLYWOOD. FASTENING TO PLYWOOD 15 ACCEPTABLE ONLY FOR SIDE CLOSURE PIECES. ANCHOR SPACING SCHEDULE • T4 C- I NS! DE"MOUNT-PANEL'S; °WALL MOUNT) 0 0 39 PENETR. LAG SCREW 45 55 Tcap (Ib) = 359.53 65 Vcap (Ib) = 82.97 72 1/4" x 2" THREAD #14 x 1 -1/2" THREAD 39 PENETR. WOOD SCREW 45 55 Tcap (Ib) = 234.00 65 Vcap (Ib) = 96.74 72 7/16" x 5/8" EMBED BRASS BUSHING & 1/4-20 SCREW Tcap (lb) = 231.50 Vcap (Ib) = 232.50 39 45 * 55 65 72 16.0" 16.0" 16.0" 10.6" 8.2" 0.75" EDGE DISTANCE 16.0" 16.0" 16.0" 16.0" 16.0" 12.4" 8.5" 5.6" 4.4" 4.4" 16.0" 16.0" 16.0" 16.0" 16.0" 16.0 16.0" 11.8" 6.9" 5.3" 16.0" 16.0" 11.7' 6.8" 5.3" 16.0" 16.0" 16.0" 15.7" 14.2" 16.0" 16.0" 16.0" 15.5" 14.0" 8.1" 5.5" 3.6" 8.0" 5.5" 3.6" 16.0" 14.4" 11.8" 10.4" 10.4" 16.0" 14.2" 11.7" 10.3" 10.3" ANCHOR SPACINGS SCHEDULE 'f INSIDE "MOUNT PANELS, TRAP MOUNT) 0 0 114" x 2" THREAD 39 PENETR. LAG SCREW 45 55 Tcap (Ib) = 359.53 65 Vcap (Ib) = 82.97 72 #14 x 1 -1/2" THREAD 39 PENETR. WOOD SCREW 45 55 Tcap (Ib) = 234.00 65 Vcap (Ib) = 96.74 72 7/16" x 5/8" EMBED BRASS BUSHING & 1/4 -20 SCREW Tcap (lb) = 231.50 Vcap (Ib) = 232.50 39 45 * 55 65 72 0.75" EDGE DISTANCE 7.5" 6.5" 5.3" 4.5" 4.1" 6.5" 57" 4.6" 3.9" 3.5" 7.7" 6.6" 5.4" 4.6" 4.1" 6.2" 5.4" 4.4" 3.7" 3.3" 13.0" 11.2" 9.2" 7.8" 7.0" 9.2" 8.0" 6.5" 5.5" 5.0" 4.8" 4.2" 4.1" 3.6" 3.4" 4. 4. 3. 3. 3. 9" 3.9" 2" 3.4" 4" j 0" 8.2" 7.1" 5.8" 5.1" 5.1" 5.8" 5.1" 4.1" 3.7" 3.7" WHERE LAG SCREWS FASTEN TO NARROW FACE OF STUD FRAMING, FASTENER 51-IALL BE LOCATED IN CENTER OF NOMINAL 2' X 4' (MIN.) WOOD STUD ( EDGE DISTANCE 15 ACCEPTABLE FOR WOOD FRAMING). WOOD STUD SHALL BE 'SOUTHERN PINE' G =055 OR GREATER DENSITY. LAG SCREW SHALL HAVE PHILLIPS PAN HEAD OR HEX HEAD. -. * DESIGNATES REMOVABLE ANCHORS, WHICH ARE REQUIRED FOR DIRECT MOUNT INSTALLATIONS. 8. MACHINE SCREWS 51-IALL HAVE MINIMUM OF '� ENGAGEMENT OF THREADS IN BASE ANCHOR AND MAY HAVE EITHER A PAN HEAD, TRUSS HEAD, OR WAFER HEAD (SIDEWALK BOLT) UN.O. ZEOULTEaniao '3. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDES STUCCO OR OTHER WALL FINISHES. Its I0. DESIGNATES ANCHOR CONDITIONS WHICH ARE NOT ACCEPTABLE FOR USE. 1 74 8 2 Z•lit22- 0 Approved tpl, 8aig with tke !Florida svi 23 o PJ ®401 0 � i I'1-o • 0 2. Miami Dade Frodua Coaf9a l FRANK L. BENNARDO. P.E. 'PE0046549 , (71 d 9 m = ril <n = IL (n X 0 4 . 4 CO F m (V N 0 Q Fri • 0 tt dl 0 l7 W W z W IL 3 3 U crc z J z 1 0_ 0 (0 1 t!L 0 J IL;L W -t z W cc I r S • 4 CV j Z D� I 0 COUNTY CO'1ENTS SHEET: 4 OF 4 03 REVISIONS DESCRIPTION DATE VI /03 SCALE: N.T.S. DRAWN BY: CL CHEGK.ED BY: FLB PRIN f DA rE: 41/18/0 DWG "o D2- 868 -III 0.G frazt`'..a EMAIL: FIRANK6FLBENGINEERING.COM 2.5" EDGE DIST. SPANS UP TO 5.50 ft SPANS UP TO 8.67 ft 1ST RUC ANCHOR LOAD CONN TYPE CONN TYPE 12.5" 16.0" (psf) C5 C6 C5 C6 CONCRETE 1/4" x 1 - 3/4" EMBED 39 16.0" 16.0" 16.0" 16.0" ELCO TAPCON 45 16.0" 16.0" 11.4" 16.0" (MIN 3320 PSI CONC) 55 16.0" 16.0" 7.5" 16.0" Tcap jib) = 483.00 65 • 14.2" - 46:0" . 6.0" 16:0" Vcap (lb) = 475.00 72 11.0" 16.0" 6.0" 16.0" 1/4 "x7/8" EMBED 39 16.0" 16.0" 14.8" 16.0" ALL - POINTS SOLID -SET 45 16.0" 16.0" 10.1" 16.0" LEAD SHIELD ANCHOR * 55 16.0" 16.0" 6.6" 16.0" Tcap (lb) = 428 65 12.6" 16.0" 5.3" 16.0" Vcap (Ib) = 429 72 9.8" 16.0" 5.3" 16.0" 1/4" x 2" EMBED 39 16.0" 16.0" 12.9" 16.0" ELCO PANELMATE 45 16.0" 16.0" 8.8" 16.0" (MIN 3350 PSI CONC) * 55 16.0" 16.0" 5.8" 16.0" Tcap (Ib) = 372.00 65 11.0" 16.0" 4.6" 16.0" Vcap (Ib) = 565.00 . 72 8.5" 16.0" 4.6" 16.0" , ANCHOR SPACING SCHEDULE • • ••• • • • ••• .• •• • • • • •• .• • • • • • • • • • • • • ANCHOR NOTES_ • • ••• • • • 1. SPANS AND LOADS SHOWN HERE ARE FOR DETERMINING ANCHOR SPACING ONLY ALLOWABLE STORM PANEL SPANS FOR SPECIFIC LOADS MUST BE LIMITED TO THOSE 51-1OWN IN MAX ALLOWABLE SPAN SCHEDULE (TABLE 2. ENTER ANCHOR SCHEDULE BASED ON THE EXISTING STRUCTURE MATERIAL 4 ANCHOR TYPE. SELECT DESIGN LOAD GREATER THAN OR EQUAL TO NEGATIVE DESIGN LOAD ON SHUTTER AND SELECT SPAN GREATER THAN OR EQUAL TO SHUTTER SPAN. 3. SELECT CONNECTION TYPE BASED ON APPROPRIATE MOUNTING CONDITION (SEE MOUNTING DETAILS ON SHEETS 2 4 3 FOR IDENTIFICATION OF CONNECTION TYPE). 4. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. 5. WHERE EXISTING STRUCTURE 15 WOOD FRAMING, EXISTING CONDITIONS MAY VARY. FIELD VERIFY THAT FASTENERS ARE INTO ADEQUATE WOOD FRAMING MEMBERS, NOT PLYWOOD. FASTENING TO PLYWOOD 15 ACCEPTABLE ONLY FOR SIDE CLOSURE PIECES. ANCHOR SPACING SCHEDULE • T4 C- I NS! DE"MOUNT-PANEL'S; °WALL MOUNT) 0 0 39 PENETR. LAG SCREW 45 55 Tcap (Ib) = 359.53 65 Vcap (Ib) = 82.97 72 1/4" x 2" THREAD #14 x 1 -1/2" THREAD 39 PENETR. WOOD SCREW 45 55 Tcap (Ib) = 234.00 65 Vcap (Ib) = 96.74 72 7/16" x 5/8" EMBED BRASS BUSHING & 1/4-20 SCREW Tcap (lb) = 231.50 Vcap (Ib) = 232.50 39 45 * 55 65 72 16.0" 16.0" 16.0" 10.6" 8.2" 0.75" EDGE DISTANCE 16.0" 16.0" 16.0" 16.0" 16.0" 12.4" 8.5" 5.6" 4.4" 4.4" 16.0" 16.0" 16.0" 16.0" 16.0" 16.0 16.0" 11.8" 6.9" 5.3" 16.0" 16.0" 11.7' 6.8" 5.3" 16.0" 16.0" 16.0" 15.7" 14.2" 16.0" 16.0" 16.0" 15.5" 14.0" 8.1" 5.5" 3.6" 8.0" 5.5" 3.6" 16.0" 14.4" 11.8" 10.4" 10.4" 16.0" 14.2" 11.7" 10.3" 10.3" ANCHOR SPACINGS SCHEDULE 'f INSIDE "MOUNT PANELS, TRAP MOUNT) 0 0 114" x 2" THREAD 39 PENETR. LAG SCREW 45 55 Tcap (Ib) = 359.53 65 Vcap (Ib) = 82.97 72 #14 x 1 -1/2" THREAD 39 PENETR. WOOD SCREW 45 55 Tcap (Ib) = 234.00 65 Vcap (Ib) = 96.74 72 7/16" x 5/8" EMBED BRASS BUSHING & 1/4 -20 SCREW Tcap (lb) = 231.50 Vcap (Ib) = 232.50 39 45 * 55 65 72 0.75" EDGE DISTANCE 7.5" 6.5" 5.3" 4.5" 4.1" 6.5" 57" 4.6" 3.9" 3.5" 7.7" 6.6" 5.4" 4.6" 4.1" 6.2" 5.4" 4.4" 3.7" 3.3" 13.0" 11.2" 9.2" 7.8" 7.0" 9.2" 8.0" 6.5" 5.5" 5.0" 4.8" 4.2" 4.1" 3.6" 3.4" 4. 4. 3. 3. 3. 9" 3.9" 2" 3.4" 4" j 0" 8.2" 7.1" 5.8" 5.1" 5.1" 5.8" 5.1" 4.1" 3.7" 3.7" WHERE LAG SCREWS FASTEN TO NARROW FACE OF STUD FRAMING, FASTENER 51-IALL BE LOCATED IN CENTER OF NOMINAL 2' X 4' (MIN.) WOOD STUD ( EDGE DISTANCE 15 ACCEPTABLE FOR WOOD FRAMING). WOOD STUD SHALL BE 'SOUTHERN PINE' G =055 OR GREATER DENSITY. LAG SCREW SHALL HAVE PHILLIPS PAN HEAD OR HEX HEAD. -. * DESIGNATES REMOVABLE ANCHORS, WHICH ARE REQUIRED FOR DIRECT MOUNT INSTALLATIONS. 8. MACHINE SCREWS 51-IALL HAVE MINIMUM OF '� ENGAGEMENT OF THREADS IN BASE ANCHOR AND MAY HAVE EITHER A PAN HEAD, TRUSS HEAD, OR WAFER HEAD (SIDEWALK BOLT) UN.O. ZEOULTEaniao '3. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDES STUCCO OR OTHER WALL FINISHES. Its I0. DESIGNATES ANCHOR CONDITIONS WHICH ARE NOT ACCEPTABLE FOR USE. 1 74 8 2 Z•lit22- 0 Approved tpl, 8aig with tke !Florida svi 23 o PJ ®401 0 � i I'1-o • 0 2. Miami Dade Frodua Coaf9a l FRANK L. BENNARDO. P.E. 'PE0046549 , (71 d 9 m = ril <n = IL (n X 0 4 . 4 CO F m (V N 0 Q Fri • 0 tt dl 0 l7 W W z W IL 3 3 U crc z J z 1 0_ 0 (0 1 t!L 0 J IL;L W -t z W cc I r S • 4 CV j Z D� I 0 COUNTY CO'1ENTS SHEET: 4 OF 4 03 REVISIONS DESCRIPTION DATE VI /03 SCALE: N.T.S. DRAWN BY: CL CHEGK.ED BY: FLB PRIN f DA rE: 41/18/0 DWG "o D2- 868 -III 0.G frazt`'..a EMAIL: FIRANK6FLBENGINEERING.COM 0.75" EDGE DISTANCE a 1/4" x 2" THREAD 39 12.5" 16.0" 16.0" 7.5" 12.5" 16.0" 12.8" 4.8" 12.5" 16.0" 8.9" 3.9" PENETR. LAG SCREW 49 12.5" 16.0" 16.0" 6.0" 12.5" 16.0" 8.6" 3.8" 12.5" 16.0" 6.3" 3.1" 58 12.5" 16.0" 14.4" 5.1" 12.5" 16.0" 6.6" 3.2" 12.5" 16.0" 6.0" r Tcap (Ib) = 359.53 72 12.5" 16.0" 9.6" 4.1" 12.5" 16.0" 6.0" 12.5" 16.0" 6.0" / Vcap (Ib) = 82.97 130 12.5" 16.0" 6.0" 12.5" 16.0" 6.0" A 12.5" 16.0" 6.0" #14 x 1 -1/2" THREAD 39 12.5" 16.0" 16.0" 7.7" 12.5" 16.0" 8.3" 4.8" 12.5" 13.5" 5.8" . 3.9" PENETR. WOOD SCREW 49 . 12.5" 16.0" 13.6" 6.1" 12.5" 13.2" 5.6" 3.8" 6.25" 10.7' 4.1" 3.1" • 58 12.5" 16.0" 9.3" 5.1" 6.25" 11.2" 4.3" 3.2" 6.25" 10.4" 3.9" j Tcap (Ib) = 234.00 72 12.5" 14.2" 6.3" 4.1" 6.25" 10.4" . 3.9" j 6.25" 10.4" 3.9" j Vcap (Ib) = 96.74 130 6.25" 10.4" 3.9" ��O/////// //////j/� 6.25" 10.4" 3.9" / 6.25" 10.4" 3.9" 7/16" x 5/8" EMBED 39 12.5" 16.0" 16.0" 13.0" 12.5" 16.0" 8.3" 8.1" 12.5" 13.4" 5.7" 6.6" BRASS BUSHING & 49 12.5" 16.0" 13.5" 10.3" 12.5" 13.1" 5.5" 6.4" 6.25" 10.6" 4.0" 5.2" 1/4 -20 SCREW * 58 12.5" 16.0" 9.2" 8.7" 6.25" 11.1" 4.3" 5.4" 6.25" 10.3" 3.8" 5.0" Tcap (Ib) = 231.50 72 12.5" 14.0" 6.2" 6.9" 6.25" 10.3" 3.8" 5.0" 6.25" 10.3" 3.8" 5.0" Vcap (Ib) = 232.50 130 6.25" 10.3" 3.8" 5.0" 6.25" 10.3" 3.8" 5.0" 6.25" 10.3" 3.8" 5.0" ANCHOR SPACING SCHEDULE • • ••• • • • ••• .• •• • • • • •• .• • • • • • • • • • • • • ANCHOR NOTES_ • • ••• • • • 1. SPANS AND LOADS SHOWN HERE ARE FOR DETERMINING ANCHOR SPACING ONLY ALLOWABLE STORM PANEL SPANS FOR SPECIFIC LOADS MUST BE LIMITED TO THOSE 51-1OWN IN MAX ALLOWABLE SPAN SCHEDULE (TABLE 2. ENTER ANCHOR SCHEDULE BASED ON THE EXISTING STRUCTURE MATERIAL 4 ANCHOR TYPE. SELECT DESIGN LOAD GREATER THAN OR EQUAL TO NEGATIVE DESIGN LOAD ON SHUTTER AND SELECT SPAN GREATER THAN OR EQUAL TO SHUTTER SPAN. 3. SELECT CONNECTION TYPE BASED ON APPROPRIATE MOUNTING CONDITION (SEE MOUNTING DETAILS ON SHEETS 2 4 3 FOR IDENTIFICATION OF CONNECTION TYPE). 4. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. 5. WHERE EXISTING STRUCTURE 15 WOOD FRAMING, EXISTING CONDITIONS MAY VARY. FIELD VERIFY THAT FASTENERS ARE INTO ADEQUATE WOOD FRAMING MEMBERS, NOT PLYWOOD. FASTENING TO PLYWOOD 15 ACCEPTABLE ONLY FOR SIDE CLOSURE PIECES. ANCHOR SPACING SCHEDULE • T4 C- I NS! DE"MOUNT-PANEL'S; °WALL MOUNT) 0 0 39 PENETR. LAG SCREW 45 55 Tcap (Ib) = 359.53 65 Vcap (Ib) = 82.97 72 1/4" x 2" THREAD #14 x 1 -1/2" THREAD 39 PENETR. WOOD SCREW 45 55 Tcap (Ib) = 234.00 65 Vcap (Ib) = 96.74 72 7/16" x 5/8" EMBED BRASS BUSHING & 1/4-20 SCREW Tcap (lb) = 231.50 Vcap (Ib) = 232.50 39 45 * 55 65 72 16.0" 16.0" 16.0" 10.6" 8.2" 0.75" EDGE DISTANCE 16.0" 16.0" 16.0" 16.0" 16.0" 12.4" 8.5" 5.6" 4.4" 4.4" 16.0" 16.0" 16.0" 16.0" 16.0" 16.0 16.0" 11.8" 6.9" 5.3" 16.0" 16.0" 11.7' 6.8" 5.3" 16.0" 16.0" 16.0" 15.7" 14.2" 16.0" 16.0" 16.0" 15.5" 14.0" 8.1" 5.5" 3.6" 8.0" 5.5" 3.6" 16.0" 14.4" 11.8" 10.4" 10.4" 16.0" 14.2" 11.7" 10.3" 10.3" ANCHOR SPACINGS SCHEDULE 'f INSIDE "MOUNT PANELS, TRAP MOUNT) 0 0 114" x 2" THREAD 39 PENETR. LAG SCREW 45 55 Tcap (Ib) = 359.53 65 Vcap (Ib) = 82.97 72 #14 x 1 -1/2" THREAD 39 PENETR. WOOD SCREW 45 55 Tcap (Ib) = 234.00 65 Vcap (Ib) = 96.74 72 7/16" x 5/8" EMBED BRASS BUSHING & 1/4 -20 SCREW Tcap (lb) = 231.50 Vcap (Ib) = 232.50 39 45 * 55 65 72 0.75" EDGE DISTANCE 7.5" 6.5" 5.3" 4.5" 4.1" 6.5" 57" 4.6" 3.9" 3.5" 7.7" 6.6" 5.4" 4.6" 4.1" 6.2" 5.4" 4.4" 3.7" 3.3" 13.0" 11.2" 9.2" 7.8" 7.0" 9.2" 8.0" 6.5" 5.5" 5.0" 4.8" 4.2" 4.1" 3.6" 3.4" 4. 4. 3. 3. 3. 9" 3.9" 2" 3.4" 4" j 0" 8.2" 7.1" 5.8" 5.1" 5.1" 5.8" 5.1" 4.1" 3.7" 3.7" WHERE LAG SCREWS FASTEN TO NARROW FACE OF STUD FRAMING, FASTENER 51-IALL BE LOCATED IN CENTER OF NOMINAL 2' X 4' (MIN.) WOOD STUD ( EDGE DISTANCE 15 ACCEPTABLE FOR WOOD FRAMING). WOOD STUD SHALL BE 'SOUTHERN PINE' G =055 OR GREATER DENSITY. LAG SCREW SHALL HAVE PHILLIPS PAN HEAD OR HEX HEAD. -. * DESIGNATES REMOVABLE ANCHORS, WHICH ARE REQUIRED FOR DIRECT MOUNT INSTALLATIONS. 8. MACHINE SCREWS 51-IALL HAVE MINIMUM OF '� ENGAGEMENT OF THREADS IN BASE ANCHOR AND MAY HAVE EITHER A PAN HEAD, TRUSS HEAD, OR WAFER HEAD (SIDEWALK BOLT) UN.O. ZEOULTEaniao '3. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDES STUCCO OR OTHER WALL FINISHES. Its I0. DESIGNATES ANCHOR CONDITIONS WHICH ARE NOT ACCEPTABLE FOR USE. 1 74 8 2 Z•lit22- 0 Approved tpl, 8aig with tke !Florida svi 23 o PJ ®401 0 � i I'1-o • 0 2. Miami Dade Frodua Coaf9a l FRANK L. BENNARDO. P.E. 'PE0046549 , (71 d 9 m = ril <n = IL (n X 0 4 . 4 CO F m (V N 0 Q Fri • 0 tt dl 0 l7 W W z W IL 3 3 U crc z J z 1 0_ 0 (0 1 t!L 0 J IL;L W -t z W cc I r S • 4 CV j Z D� I 0 COUNTY CO'1ENTS SHEET: 4 OF 4 03 REVISIONS DESCRIPTION DATE VI /03 SCALE: N.T.S. DRAWN BY: CL CHEGK.ED BY: FLB PRIN f DA rE: 41/18/0 DWG "o D2- 868 -III 0.G frazt`'..a EMAIL: FIRANK6FLBENGINEERING.COM SEE NOTE 4 ON SHT. 4 SEE GLAZING DETAILS, SHEET 7 SEE NOTE 6 ON SHT. 4 0.75 ® SEE NOTE 5 ON SHT. 4 \__SEE DETAIL 5 ON SHEET 5 HORIZONTAL CROSS SECTION \.,V AT SIDEUTE TO LATCH JAMB NOTES; 1. SPACING FOR ITEM 126 THE 110 x 1' PFH SCREWS ATTACHING THE IMPERIAL ASTRAGAL 10 THE INACTIVE DOOR IS AS FOLLOWS: FROM THE TOP DOWN & THE BOTTOM UP: 1.0', Z5", 4.0; 5.5', 13.0', 18.0' & 26.0 ". 2. SPACING FOR REIN 123 THE 18 x 1 1/2' PLASCREW 1S AS FOLLOWS: TOP & BOTTOM. HORRONT I I Y SD IE 3.0 IN FROM EACH CORNER ON THE SIDES. VERRTCALLY. FOR THE SIDEUTE PANELS; 3.0', 13.0 ; 26.0', 39.0', 520' & 63.0'. 3. SPACING FOR REM 131 THE 16GA x 3/4' BRAD TRIM NAIL ATTACHING THE QUARTER ROUND 10 THE SIDELITE AND ITEM 19 THE 1600. X 1' BRAD TRIM NAIL ATTACHING THE MULLION CAP 10 THE MUWON BAR VERTICALLY, IS AS FOLLOWS: TOP & BOTTOM HORIZONTALLY (FOR THE 3/8' QUARTER ROUND); 1.25' IN FROM EACH CORNER WITH (1) NAIL MID -SPAN. ON THE SIDES VERBALLY ALLY (FOR BOTH 3/8' OUARTFR ROUND & M ' ' CAP); 1.25' FROM EACH END & SIX MORE EQUALLY SPACED ON THE FIELD. 4. WHEN ATTACHING THE STRIKE PLATE TO THE JAMB AND BUCK USE REM 125, A 18 x 2 1/2' PFH WOOD SCREW. WHEN ATTACHING THE STRIKE PLATE TO THE JAMB AND SIDELITE JAMB AT THE MUWON USE ITEM 124, A 18 x 2 PFH WOOD SCREW. 5. SPACING FOR ITEM 125 THE 18 x 2 1/2 PFH WOOD SCREWS ATTACHING THE JAMBS TOGETHER AT THE MUWON, 15 AS FOLLOWS: 6.0' FROM EACH VERTICAL CORNER WITH (4) MORE SCREWS EQUALLY SPACED ON THE FIELD, 6. THE SIDELRE PANEL IS SECURED INTO THE SIDEUTE JAMB W/ ITEM 129 SILICONE CAULK ON THREE SIDES AND 3/8' QUARTER ROUNDS SECURED WITH REM 131 BRAD TRIM NAILS x 3/4' LONG 7. WHEN ATTACHING THE HINGE Ti) THE JAMB AND BUCK USE ITEM 127, A 110 x 2' PFH SCREW. WHEN ATTACHING THE HINGE TO THE JAMB AND SIDELITE JAMB AT THE MUWON USE REM 114, A 110 x 1 3/4 PFH WOOD SCREW. 8. SPACING FOR ITEM 149 THE 16 x 1 1/2 PANHEAD SCREW (TRINITY UTEFRAME) IS AS FOLLOWS: SIDELITE LITEFRAME FROM THE TOP DOWN VERTICALLY. 3.25; 18.0625', 32.8125 ", 47.5625' & 62.625 ° . 51DELRE UTEFRAME TOP & BOTTOM. FROM THE LEFT: ONE (1) SCREW AT 4.4375'. 9. ALTERNATE CONCRETE /MASONRY INSTALLATION ANCHORS OF EQUIVALENT PERFORMANCE CHARACTERISTICS CAN BE USED UPON APPROVAL OF THE ARCHITECT OR ENGINEER OF RECORD FOR THE PROJECT OF INSTALLATION. 10. USE ITEM 151 WHEN INSTALLING INTO WOOD SUBSTRATE AT HEAD & JAMBS. USE ITEM 125 WHEN INSTAWNG INTO MUWONS. USE REM 116 WHEN INSTAWNG INTO CONCRETE/MASONRY SUBSTRATE AT SIDELITE SILLS. MASONRY BY OTHERS MOE 1.50' MIN. EMBED. 1.75" MK PANEL 1HK. SEE NOTE 5 0 ON SHT. 4 SEE DETAIL 5 ON SHEET 5 rON HORIZONTAL CROSS SECTION ‘....41 AT SIDELITE TO HINGE JAMB 3 1 SEE NOTE 3 V.VON SIR: 4 0.25' MAX SEE NOTE 2 ON SHIT: 4 SEE NOTE 6 ON SHT. 4 SEE DETAIL 5 ON SHEET 5 0.125 MIN GLASS fl HORIZONTAL pRoss SECTION AT SIDEUTE 10 BUCK Erie S. run l Rartda P. E. No. 41323 1 Rookladao, Flmtde 32853 vane aRmrmmr m AMorfegk , NR MS SEE NOTE 2 • • •�� •0N SHE 4• • • • • SEE NOTE.• • • ON SHT.•4 • • •••• SEE MAINS • • 0.75" • • • • DETAILS, SHEEL 7 • • • • • • •••• •••• • •• • • • • • • •••• •• • • • •• • • • • •• • •••• SEE•GLAZING • DEVILS, SAT 7 • •••• • •••• EXTERIOR INTERIOR SEE NOTE 7 ON SHE 4 Prepared By: Ar PTC, LLC Phan .321-680-1788 Far 321 - 690-1789 PRODUCT REVISED as complying with the Florida Building Coda Acceptance No tt Expiration A•■ • • By :.: �L' ' Miami � .• ,. Conhol Division i *al 1i 1 ug: -19 gg GATE. 9 -11-01 scnlx: N.T.S. DWG. Eft JWJ aa. er. S. SAFFEL. CROWS NO.: 5-2104 slain of 8 81.25' MAX. OA FRAME HEIGHT SPACES 0 13.85' 74.5 MAX. OA FRAME WIDTH SEE DETAIL 2 ON THIS SHT. 36.625' SEE DETAIL 5 ON THIS SHT. — 7.375 DETAIL 2 - 0 MEAD JAMB DETAIL 3 - 0 THRESHOLD OEINL 4 ASTRAGAL STRIKE PLATE ASTRAGAL STRIKE PLATE HINGES TO JAMB & DOOR SEE DETAIL 4 ON MIS SHT. SEE NOTE 7 SHEET 4 81.25' MAX. 0A FRAME HEIGHT SPACES 0 13.85" 36.625' DETAIL 5 STRIKE RATES TO JAMB STRIKE PLATES 70 ASTRAGAL 4.5' 3' TYP. — 3' TYP. 1 b sir DETAIL 6 014 THIS SHT. rr 15.50' 70.25' MAX. 0A FRAME WIDTH SEE NOTE 4 SHEET 4 9' TYP. 6' TYP. 3' TYP. •••• • • • • •••• • • • •• • •••• • • • •• • •• • • • • • • •••• • • • • • •• • Qum MA1e: 9 -11-01 scam N.T.S. 01x1. BY: JWJ cltK. eh S. S4FFELL (r)(8 -, Florida Edo S. Woo P. E No. 44323 t Rooklodgo, Florida 32955 MPH Nrtmcate et Auk„ NO. MU Prepared By: 4111.INN. P1C, LLC Phone 321 -690-1786 Fate 321- 690 -1789 PRODUCT REVISED as complying with the Florida Building Code Acceptance No Expiration 411 41I; MENG Ma 5-2104 • • • • 9023 os • • • g F / 1 11 16.41' TYP. 9° IYP. 1 / / ' 13.41 T g F / 1 16.41' TYP. 9° IYP. 1 I . 13.41 T _ 1 Er 11 I 111 1 11 1 1 11 ! ! 1 _ T T i 1 36.625' e 1 r e _ 4.5 3 r TYP. .3 SEE DETAIL .3 ON SHEET 5 02111E 000R W11 S T ELRES ANCHOR LOCATE VIEWED FROM INTERIOR SEE DETAIL 4 ON SHEET 5 36.625' 6 -1TYR 6 SPACES 0 11.54 81.25 SEE DETAIL 6 MAX. TON SHEET 5 OA 1 — 1 HEIGIDE 5.50' I 1 37.75 MAX OA I FRAME WIDTH • 8.58°_ TYP. L 7.375 31‘ • •• • • • 3f. E: SINGLE DOOR WRHOUT SIDELRES ANCHOR LOCATIONS VIEWED FROM INTERIOR 217/(Q_ E .:1Ivo) Florida P E E 41323 1 Roaidadoe, Florida 32255 F7#CE CeNBc.h at 40t .4 . M. 25935 SEE DETAIL 4 / ON SHEET 5 • • • • • •••• • • • •••• • • • • • • • • • •• • •• PRODUCT REVISED as comp;ytg with the Florida Building Code Acceptance No O -0 /. 04 Exp ra3rio� Date a • By Division ado Product Control •• • • • • •• • •• • • • • •••• • •• • • • •• • • •• • • • • •••• .•.• • • •••• Prepared Br PTT;, LLC Phone: 321 -590 -1788 Far 321- 690 -1789 in 1 mG WEI 9 -11-0 sum N.T.S. DWG. WI': JWJ stet. sr. S. SWELL DRAWING N04 S -2104 SHEEP O'8 • a . a 1.50 MINI CONCRETE/ J EMBED. MASONRY BY OTHERS SHIM 1.75' MIN PANEL THK ( HORIZON CR OSS SECTION C J TO ENRIZ HORIZONTAL CROSS SECTION AT IMPERIAL ASTRAGAL • •• • ••• ® HORIZONTAL CROSS SECTION HINGE JAMB TO BUCK SEE NOTE 1 SHT. 4 1.75° MIN. PANEL THK. SEE DETAIL 5 ON SHEET 5 0.25 MAX. SHIM DETAIL 1 ASTRAGAL 10 STILE ATTACHMENT NOTE ITEM 24 NOT SHOWN TH5 VIEW FOR CLARITY 1.50' MIN. EMBED. Florida P. E. No. 41323 1535 Copan Streak qt, Florida �33� FF E caNbao of auatuettaaton M. 25935 SEE NOTE 7 ON SHT. 4 • PRODUCT REVISED as complying with the Florida Building Code Acceptance No • • Expiration Date O :TI 2 O/L BY Division •. • • • OM (NIIE •• • • •• • • • • • •• • • • • • • • ASTRAGAL THROW BOLTS (2) TOT (1 EACH) • • 0.31' DIA x 9.0 LG. A: Tale trial • • • •••• • • • • •••• • • • •• • •• • • • • •• • Prepared By: B ' PTC, LLC Phonon 321 -690-1788 Fax 321- 690 -1789 ado Product Con 10 DAIS 9- 1 -0 N.T.S. mom 0 . BY: JWJ C3IX. sw S. SAFFELL CRAMS NO4 5 -2104 sttEr 3 Of 8 EXTERIOR INTERIOR 1.50 MIN. 0.25° EM MAX. SHIM 81.25" MAX. OA FRAME HEIGHT 134 MIN. EMB. EXTERIOR INTERIOR CONCRETE/ MASONRY BY OTHERS EE DETAIL ON SHEET 5 • SEE NOTE 9 ON SHT. 4 1.75" 50" MIND MW. EDGE DIST. g VERTICAL CROSS SECTION 2 WITH HIGH DAM THRESHOLD 1.75" MW PANEL THK -_J MAX. O.A. PANEL HEIGHT .825" CONCRETE/ MASONRY BY OTHERS SEE NOTE 2 ON SHT. 4 0.50" GLASS BITE GIA7ING DETAIL 1 01X. LITE FRAME SINGLE PANE 1/8' TEMPERED GLASS SPARTECH POLYGON PP5530 C13 O1AZ1NG DETAIL TRINITY LITE FRAME 1' INSULATED TEMPERED GLASS LUPOY EU -5007 0.125" MIN. UP. GLASS THICKNESS 1.50° MIN. 0.25" EMB. MAX. SHIM 81.25" MAX. 0.A. FRAME HEIGHT .1141(:• : Nam EE DETAIL 7 / "' ON SHEET 5 SEE NOTE 8 ON SHT. 4 CD 0.125 MIN. G SEE NOTE 2 ON SHT. 4 SEE NOTE 2 ON SHT. 4 SEE NOTE 6 ON SHT. 4 SEE NOTE 8 ON SHT. 4 SEE DETAIL 7 ON SHEET 5 1.75" MIN. PANEL THK. GLASS THK. SEE GLAZING DETAILS, SHEET 7 1.25" .75 .50" MI MIN. MW. EDGE DIST. EMB. VERTICAL CROSS SECTION AT SIDELITE SASH 0.125' •TEMP. 0.125' TEMP. GLASS CONCRETE/ MASONRY BY OTHERS SEE NOTE 3 ON SHT. 4 SEE NOTE 3 ON S . 4 80.0 MAX. OA. PANEL HEIGHT CONCRETE/ MASONRY BY OTHERS GANG DETAIL 2 TRINITY LDE FRAME GLASS 1/2' MATED TEMPERED GLASS LUPOY EU -5007 8 Edo &,`( Florida P. E. Na. 41323 FTC. LLD 1522 Ceprooll Street, C25 Roof k. Rondo 3295S ME own= m AtMwll5Im No. Florida P. . 41323 1 Roddsdge, Florida 32855 (WWE ae•Am• al Adhannitka No. Prepared By: AF PTC, 1.1.0 Phone: 321 - 890 -1788 Fax: 321 - 690 -1789 • • • • • • •• • • •••• • • •••• •• • • • • • • • • • • •• • PRODUCT REVISED complyin viw are Fto.ida Building Code Aaeptmix NoO Division •• • • • • •• • •• • • • • • • • •• • • • • •••• • •• • • • •• • • •• • • • • • • • • •••• • • • • • • •••• • •••• •••• • • • •• • • •• • • • • • •• •• • • • • •0 • Prepared By. PIC, TLC Phone: 321 -690 -1788 Fox 321 -690 -1789 t 11. 4NE IR IaM E: 9 -11 -01 sal& N.T.S. OM Ells JWJ CPR No S. SAFFELL MONO NO 5 -2104 s firt of 'o.ODUCT REVISED as complying with tcl lha Florida 4 N A 31� Accepltance No Expiration Date ills • ado Product Control Division .1 ha; •••• • • • • • %( •• •• •if • •••• —� • • n A A m a DATE: 9- 1 -0 s;ALEE N.T.S. ••t 1 ••w ag owo. er: JWJ cm. BY: S. SAFFELL MOAN* NO.: S -2104 • ••• • • •. +. • sir. 7 OF A • • •• • • • iT • • • 1 S 1 DOOR STEEL FACE SHEET 24GA. 0.020"MIN.) STEEL 2 FRAME HEAD (FINGER JOINTED PONDEROSA PINE) WOOD 3 FRAME HINGE JAMB FINGER JOINTED PONDEROSA PINE) WOOD WOOD 4 FRAME LATCH JAMB (FINGER JOINTED PONDEROSA PINE) 5 • "4/1 /1 Hat •,. 4 3. 7132 19 X 1" PFH WOOD SCREW (HINGE TO DOOR) STIi•1 DOOR LATCH STILE LVL OUTSWING PEMKO BUMP FACE THRESHOLD ALUMINUM BRAD TRIM NM. 16G4. X 1" (FOR MULLION CAP) STEEL COMPRESSION WEATHERSTRIP FOAM DOOR TOP RAIL LW. DOOR BOTTOM RAIL STEEL DOOR HINGE STILE (FINGER JOINTED PONDEROSA PINE) WOOD 110 x 1 3/4" PFH WOOD SCREW STEEL. WOOD LOCK BLOCK (FINGER JOINTED PONDEROSA PINE) 3/18" Me TAPCON ANCHOR W/ 1 1/4" MIN. EMBED. STEEL EXPANDED POLYSTYRENE 1.0 to 1.25 Ib. cT DEN BY JELD -WEN . •.,, 18 NOT USED - 19 2x WOOD SUB BUCK WOOD - 20 SHIM (0.25" MAX. THK. HIGH DENSITY PLASTIC OR GREATER) 21 LKSET . 'RIP K L: 1L 23 ; 8 x 1 1 2 PLASCREW ODL LITE FRAM • STEEL 24 x 2" PFH WOOD SCREW S7)L .4T,$1, • •L • 25 8 x 2 J2" PFH WOOD SCREW • 28 1 1 PFH WOOD SCREW (IMPERIAL ASTRAGAL TO DOOR). 110 27 x 2" PFH WOOD SCREW STEEL 28 MULLION CAP • ... 29 SILICONE CAULK (CR LAWRENCE .33 C) • -, �^ 30 GLAZING COMPOUND OSD BY 0• .. BRAD TRIM NAIL 16GA. x 3 4 FOR 3 8 QUARTER. ROUND. • 1 B}Ea 3/8" QUARTER ROUND SIDELITE STOP. CORN 4; iL .6. ,1! R 713 • ! • - Bono RAI • • ere SCHLAGE KNOB SET !F51 • • SL SCH • DEADBOLT := :' NOT SHOWN ■R r ' ` 1 ni 0.020 MIN. STEEL 37 1 8 TEMPERED GLASS BY PPG 38 OOL UTE FRAME SG SPARTECH POLYCOM PP5530 013 €715 d1a ALUMINUM a ' •a. ASTRAGAL : IMPERIAL ASTRAGAL STRIKE PLATE (BY IMPERIAL) Y ___ .1 ii; a TNIL# 43 YALE DFADBOLT 1-4 AGE SERIES NOT SHOWN STEEL WOOD . YPROP. SIDELITE FRAME . SILL AND JAMBS (FINGER JOINTED PONDEROSA PIN 45 }t7E FRAME BY TRINITY FOR 1 2 ` I.0.U. 46 yr INSULATED TEMPERED GLASS (BY TRINITY /AMPAC) GLASS 47 IL 21- 4 1; . 11 i.; : , PO YPROP. as r7 . .., . , cam' rri 0 50 GLAZING COMPOUND DOW 1199 SILICONE 51 110 W000 INSTALLATION SCREW W/ 1.50" MIN. EMBEDMENT 52 DOOR LATCH STRIKE PLATE STEEL STEEL 5.3 DOOR LATCH DEAD BOLT STRIKE PLATE STEEL EXTERIOR INTERIOR 1.50 MIN. 0.25° EM MAX. SHIM 81.25" MAX. OA FRAME HEIGHT 134 MIN. EMB. EXTERIOR INTERIOR CONCRETE/ MASONRY BY OTHERS EE DETAIL ON SHEET 5 • SEE NOTE 9 ON SHT. 4 1.75" 50" MIND MW. EDGE DIST. g VERTICAL CROSS SECTION 2 WITH HIGH DAM THRESHOLD 1.75" MW PANEL THK -_J MAX. O.A. PANEL HEIGHT .825" CONCRETE/ MASONRY BY OTHERS SEE NOTE 2 ON SHT. 4 0.50" GLASS BITE GIA7ING DETAIL 1 01X. LITE FRAME SINGLE PANE 1/8' TEMPERED GLASS SPARTECH POLYGON PP5530 C13 O1AZ1NG DETAIL TRINITY LITE FRAME 1' INSULATED TEMPERED GLASS LUPOY EU -5007 0.125" MIN. UP. GLASS THICKNESS 1.50° MIN. 0.25" EMB. MAX. SHIM 81.25" MAX. 0.A. FRAME HEIGHT .1141(:• : Nam EE DETAIL 7 / "' ON SHEET 5 SEE NOTE 8 ON SHT. 4 CD 0.125 MIN. G SEE NOTE 2 ON SHT. 4 SEE NOTE 2 ON SHT. 4 SEE NOTE 6 ON SHT. 4 SEE NOTE 8 ON SHT. 4 SEE DETAIL 7 ON SHEET 5 1.75" MIN. PANEL THK. GLASS THK. SEE GLAZING DETAILS, SHEET 7 1.25" .75 .50" MI MIN. MW. EDGE DIST. EMB. VERTICAL CROSS SECTION AT SIDELITE SASH 0.125' •TEMP. 0.125' TEMP. GLASS CONCRETE/ MASONRY BY OTHERS SEE NOTE 3 ON SHT. 4 SEE NOTE 3 ON S . 4 80.0 MAX. OA. PANEL HEIGHT CONCRETE/ MASONRY BY OTHERS GANG DETAIL 2 TRINITY LDE FRAME GLASS 1/2' MATED TEMPERED GLASS LUPOY EU -5007 8 Edo &,`( Florida P. E. Na. 41323 FTC. LLD 1522 Ceprooll Street, C25 Roof k. Rondo 3295S ME own= m AtMwll5Im No. Florida P. . 41323 1 Roddsdge, Florida 32855 (WWE ae•Am• al Adhannitka No. Prepared By: AF PTC, 1.1.0 Phone: 321 - 890 -1788 Fax: 321 - 690 -1789 • • • • • • •• • • •••• • • •••• •• • • • • • • • • • • •• • PRODUCT REVISED complyin viw are Fto.ida Building Code Aaeptmix NoO Division •• • • • • •• • •• • • • • • • • •• • • • • •••• • •• • • • •• • • •• • • • • • • • • •••• • • • • • • •••• • •••• •••• • • • •• • • •• • • • • • •• •• • • • • •0 • Prepared By. PIC, TLC Phone: 321 -690 -1788 Fox 321 -690 -1789 t 11. 4NE IR IaM E: 9 -11 -01 sal& N.T.S. OM Ells JWJ CPR No S. SAFFELL MONO NO 5 -2104 s firt of 'o.ODUCT REVISED as complying with tcl lha Florida 4 N A 31� Accepltance No Expiration Date ills • ado Product Control Division .1 ha; •••• • • • • • %( •• •• •if • •••• —� • • n A A m a DATE: 9- 1 -0 s;ALEE N.T.S. ••t 1 ••w ag owo. er: JWJ cm. BY: S. SAFFELL MOAN* NO.: S -2104 • ••• • • •. +. • sir. 7 OF A • • •• • • • iT • • • 1 S DESIGN PRESSURE RITIND -WERE U Rlf1]RAINXI mew 6 NEEDED VW Dow ma (4 ox. » 0l0) NM NON- RR'•T SIDDIIF5 413&87 pay -70 psi DOME 01108 UN/ (A OA XXq OxXO) 457 Psi - 57 Pal R O NOR -REDACT SIDDIIES 1.67' -1 n n 121' 000R 80TTO4 RAIL 12 24GA (0.021, STES. 1- 1.645' 0.831' ea* O CORNER BLOCK STEEL BOTTOM RAIL MOF x 3.0" LONG 1.50' 1 � 0.62' 1.75" ASTRAGAL HAS TWO 0.3125' DM. x 9' LONG BOLTS; 1 ON TOP, 1 ON BOTTOM -I 1.02' I- O 606346 ALUMNA! 1.6n 1 1.00" 000R H1NGE STILE 13 FINGER JOINTED PONDEROSA PINE WOOD ,� 0 3B• t 0.50' 0.14' 0.53' 10 SCHLECEI. Q-LON QDS 650 2.50' 1.25' k. O 0 ASTRAGAL S1I8KE PLATE 41 (IMPERI#L 0.125' STEEL) 11.875' DIA VARIES WM 0 / - HARDWARE USED WOAD LOCK BLOCK 15 FINGER JOINTED PONDEROSA PINE r _ 1.67' --I J L ®000R l47CH STILE LW. 0.48' - 1.00' _L -�I 1- 0.513' 1.11 1.7�r ❑ I- 1.36' OAR LATCH STRIKE PLATE STEEL 11 DOOR TOP RA11 LV1 1 I+- 1. 52 1--- 2.52' cy /2' I.G. TRINITY UTE FRAME POLYPROP. 214' 1.01' 1.67' 1.04 2' 0.87' 4 r t . 0.58' 1 O O Gi6,U! B a; POLYPROP. IMR LATCH QEAD MULLION CAP O ST OPINE (81.25 LONG) 4.00' I 1.71' 1 1.013' {- 0.375 0.375 ° --I I O J /8' QUARTER ROUND 32 $IDELOE STOP PINE --I 1.375' I-- • Ede S. Florida P. E. No. 41323 PM, LLC 1535 Cowan Strut. 91xa C25 RooWadgo. Florida 32955 FeF[ 1.6546. or Aae.ntWOa I. 250.0 EY - f - 0.125' j / / / // ∎• ∎• ∎• te S (LUTE FRAM° • • • ••• • ROP • •• •• •• • • • • •••• • •• • • r••et •••• • • •• • e). • A 0.097" -4- )--- -- 4.000' • • • • HAGER STEEL BUTT HINGE (-5-) 4' x 4' x 0.097' TUC STEEL • -- 1.00" 4.041' \���\ 0.58' 4.041' (DO UTSWING STANDARD EXTRUDED ALUMINUM FACE Y PEMKOO YAM WOOD INSERT Prepared 8y. PTC, LLC Phone: 321-690-1788 For 321 - 690 -1789 PRODUCT REVISED e: wierlying with the Florida Coda AcccpW c No Expiration Date • s • • • •• • •• • ORAIN NG N O S -2104 a4 tea^ 101. 411; • • ••• • ♦• • • • JELE WEN® Steel 8-0 'W00Dl 'IDP s7 L 007516&1X1 IMMCTDOOR UNITS (19tH #WIfHOUT887 LI7ES GENERAL NOTES 1. MRS PRODUCT IS DESIGNED TO COMPLY KM THE 2004 FLORIDA BWLDOIG CODE (W /210 5 & 2008 SUPPLEMENTS) AND HIGH VELOCITY HURRICANE ZONE 14712' REQUIREMENTS. 2. WOOD 8t0KS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRAINER LOADS TO THE STRUCTURE 3. PRODUCT ANCHORS SNALI. BE AS USIED AND SPACED PER AMOR LOCATION DRAWINGS. ANCHOR EMBEDMENT TO BAS' MATERIAL SMIL BE BEYOND WALL DING OR STUCCO. 4. SUE TABLE 1 ON MIS SHEET FOR DESIGN PRIG RATINGS. 5. MS PRODUCT WATER REQUIREMENTS FOR 16/1Z" ZONES SEE THE DESIGN CH ART :ia r 6. 510ELf1E5 REQUIRE MIAMI -. r APPROVED IMPACT RESISTANT SHUTTERS. 7. MIAMI APPROVED IMPACT RESISTANT SHUTTERS ARE REQUIRED FOR 000RS W/ AN OXXO & XX CONFIGURATION, BUT NOT ON OZ X OR OX0 CONFIGURATIONS. 8. SIDEl11ES ARE AN OPTION AND CAN BE USED IN A SGXiE OR DOU&E CONFIGURATION. R / TIALDGUTA1FDSTEE LD00R (Comma toa0erne captions) COMPONEVTCONSTRUCTIOH9: &MAW& 24 go. (0.0209 mhn(mwn thickness, Gahar*ed Steel A - 525 commercial quality - A � per ASTM 620 with overage minimum yl&d strength Fy(ae.)=24,600 psi. GgnLAuts Expanded paystyrerre with 1.0 to 125 Ib& /cf density. by Ooar Pored ConabteeHom The active and Inactive panels are consbucted from 24GA. (0.020' min.) galvanized std The face sheet tops and bottoms are bent 90' over the top and bottom rails. The top LW rail mamas 1.67' wide x 1. 042' high. The steel bottom rail Is roll formed 0.021' galvanized steel meaeuring 1.67' wide x 121' hlgh. The sides of the face sheet are roil formed onto the LW. latch stile and Ponderosa Pine hinge stile which measure 1.67' x 1.0". The Interim cavity Is MW with polystyrene. The face sheets are glued to the polystyrene. • 0061.11104016; The cash Is constructed from 2400. (0.020' nth.) galvanized steei. The edges of the face sheet are bent 90' over the polystyrene cow and glued to It. The Shute panels are routed to receive the OOL Up Lite Frames or the optional Trinity Light Frames. (see sheet 7 for glazing details.) The tits frames are seated w/ 05D glazing compound on the mderior. Franco Constnrct78, The frames are cons rutted from Ponderosa Pie Jambs measuring 1.25' wide x 4.5625' deep. The door and side0te lead jambs WO mortised and butt Joined to the side jambs and attached with (3) 160A, 2' x 7/16' crown wire stoplea. The wilts use a standard bump faro Pemko t measuring 4.041' duo x 1.0' high. The threshold is attached to the frame with (3) 16G% 2' x 7/18' crown wins staples 1 SHT / 2 3 4 5 6 7 ANT COMPONENTS TAOEOFOONfEVTS DESCRIPTION GENERA. NOTES AND TYPICAL ELEVATIONS VERTICA1 CROSS SECTIONS AND BILL OF MATERIALS HORIZONTAL CROSS SECTIONS HORIZONTAL CROSS gams AND NOTES ANCHORING LOCAMONS AND DETAILS ANCHORING LOCATIONS AND D6A75 GAZWG DETAILS 8125" MA), OA. FRAME HMG .875' TYP. 0.625' 81.25' MAX. 0A FRAME MINT 0.625' 80' MAX. OA PAhffl. HEIGHT .875' TM 0 74.5' MAX. OA FRAME WIDTH --�- .125' 36.625' MAX 0A 38' MA), OA PAD MioTH PANEL WIDTH W /AS►RAC.V 3715' MAX OA FRAME WIDTH 0A MEL WIDTH PI • v v v t3J 0 SINGLE 0U15WING IMPACT UNIT (X) 3tE 1: l DOUBLE OURS 770 IMPACT UNIT fa) l 80' MAX 0A PANEL HEGHT 8125' MAX 0A FRAME HEIGHT 0.75' 81.25' MAX. OA II FRAME HEIGHT 80' MAX. 0A PANEL HEAR 0.625' 7025' MAX 0A FRAME WIDTH .75' .75' MUIL h_ TYP. ! BAR TYP. .875' 36' MAX OA PANEL WIDTH 15.5' MAX. 0A SMUT FRAME WIDTH 14' MAX. OA PANEL WIDTH 7i IE77 .; 71 Il ➢:d::. 1 .119; , 9: 015' - 0.625' 107' MAX OA FRAME WIDTH .125' 75' MULL 38.625' MAX OA. 8411 1W' 38' MAX OA MAMMAL FVJ01 wow Florida PM. LLC 1535 Cogswell Florida Street. Suite 025 WIC a.tio°ale of Aae.R.SOa Na 26934 6' MAX. 0A D.LO. WIDTH i WIDTH • 1 4' !4!L•OIA. • • • eltun re • • • ^Y'• • •• • • •• •• 6' MAX •1ELA■ • • • .._... • 63. 25' 141), OA DLO. Hew • • ▪ • i •••• ••• •• • • • •• • • • • • • •• • • • • • •••• •• • • • • •• • pow 07)56910 IMPACT UNIT OM W/ MOM �EMQR Prepared 8y: /M.. P1C LLC Phone: 321 -690 -1786 Fax: 321 -690 -1789 PRODUCT REVISED as can:plying with the Fiords Eal!!1:2, Code N o 6 Q N:isaddl Product Coaled Division • roof 9 -11 -01 SOLE N.T.S. wile err. JWJ SAFFELL DRAWING tEla 5 -2104 star 1 arL ,Teld -Wen, Inc. (OR) ... • • • ... • • • .. .. • • • • • • • • • • • • • • • NOTICE OF A (+ P'FA?E; _ ; E'IDENCE SUBMITTED A. DRAWINGS • • • • • • • • 1. Manufacturer's Ali cfrapvingsinel . 2. Drawing No S -2104' titled "5'er+o Woodlige Opaque Outswing Steel Impact Door Up to 9' -0 "x 6' -8" with and without Non - Impact Sidelites ", sheets 1 through 8 of 8, dated 09 /11/2001 w th.e; i §ian ) ; et 07411/2007, prepared by PTC, LLC, dated 07/19/2007, signed and %aced b Frk S.aGielsen, P.Fr. • ••. • •• B. TESTS 1. Test reports on: 1) Air Infiltration Test, per PA 202 -94 2) Uniform Static Air Pressure Test, Loading per PA 202 -94 3) Water Resistance Test, per PA 202 -94 4) Forced Entry Test, per PA 202 -94 5) Cyclic Wind Pressure, Loading per PA 203 -94 6) Large Missile Impact Test, per PA 201 -94 along with marked -up drawings and installation diagram of Outswing and Inswing wood edge opaque steel door, prepared by Certified Testing Laboratories, Test Report No. CTLA -696W, date 11/01/2001, signed and sealed by Ramesh Patel, P.E. (Submitted under NOA# 02- 1211.18) C. CALCULATIONS 1. Anchor verification calculations and structural analysts, complying with FBC -2004, prepared by PTC, LLC, dated 07/11/2007, signed and -sealed by Eric S. Nielsen, P.E. Complies with ASTM E 1300 -02 D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS 1. None F. STATEMENTS 1. Statement letter of conformance, no financial interest and compliance, dated 07/19/2007 by PTC, LLC, signed and sealed by Eric S. Nielsen, P.E. 2. Laboratory addendum letter for Test Report no. CTLA -696W, issued by Certified Testing Laboratories, dated 04/11/2002, signed and sealed by Ramesh Patel, P.E. (Submitted under NOA# 02- 1211.18) 3. Laboratory compliance letter for Test Report no. CTLA -696W, issued by Certified Testing Laboratories, dated 11/11/2001, signed and sealed by Ramesh Patel, P.E. (Submitted under NOA# 02- 1211.18) G. OTHER 1. Notice of Acceptance No. 02 1211.18, issued to Jeld -Wen, Inc. (OR) for their Series "Outswing Opaque Wood Edge Steel Door Up to 107 "x 6' -8" Units ", approved on 01/30/2003 and expiring on 08/15/2007. E -1 J ; me D. Gascon, P.E. Chief, Product Control Division NOA No. 07- 0731.04 Expiration Date: August 15, 2012 Approval Date: December 20, 2007 • • ••• • •• •• • • • • • • • • • • • • • •• • • • • • ••• • • • • • • MIAMI-DADE COUNTY, FLORIDA • ' • • • METRO -DADE FLAGLER BUILDING X40 WEST FLAGLER STREET, SUITE 1603 • ••• BUILDING CODE COMPLIANCE OFFICE (BCCO) MIAMI, FLORIDA 33130 -1563 PRODUCT CONTROL DIVISION • • • • • • • • (305) 375 -2901 FAX (305) 372 -6339 NOTICE OF ACCEPTANC iSQA) ••, • • • www.miamidade.gov/buildinecode Jeld -Wen, Inc. (OR) • • ' • • • • • ' • 3737 Lakeport Boulevard 1 , Klamath Falls, OR 97601 • • • • • • • ••• • • SCOPE: NIP • • ' • • • This NOA is being issued under the applivabl€ rPlles'anc+ rhttletioregoverning the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series 6'8" W/E Outswing Opaque Steel Doors - L.M.I. -w/wo Sidelites—N.I. APPROVAL DOCUMENT Drawing No. S -2104, titled "Series Wood Edge Opaque Outswing Steel Impact Door Up to 9' -0"x 6' -8" with and without Non - Impact Sidelites", sheets 1 through 8 of 8, dated 09/11/2001 with revision D dead 07/11/2007, prepared by PTC, LLC, dated 07/19/2007, signed and sealed by Eric S. Nielsen, P.E., bearing the Miami -Dade County Product Control Revised stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large Missile And Small Missile Impact Resistant/ Non - Impact Resistant LIMITATION: Miami -Dade County Approved Impact Resistant Shutters are required for Double Doors and for Sidelites. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews-NOA # 02- 1211.18 and consists of this page 1 and evidence page E -1, as well as approval document mentioned above. Th 'tted documentationwas reviewed by Jaime D. Gascon, P.E. .O (, I G O / NOA No. 07- 0731.04 Expiration Date: August 15, 2012 Approval Date: December 20, 2007 Page 1 REPLACE BACH DOOR OF GARAGE, SHUTTER FRONT ENTRY DOOR, AND SHUTTER GARAGE WINDOW /6( 8 Passed / Inspector Comments / Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid . until Inspection Date: 08/28/2008 Inspector: Grande, Claudio Owner: MIZELL, MILTON Job Address: 80 93 Street NW Miami Shores, FL 33138- Project: <NONE> Contractor: HOME OWNER Building Department Comments Thursday, August 28, 2008 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Permit Type: Windows /Shutters Inspection Type: Final Work Classification: Window /Door Replacement rt- Block: Phone Number (305)758 -1836 Parcel Number 1131010170020 Lot: Page 1 of 2