Loading...
736 NE 92 St (3)HVAC DESIGN REQUIREMENTS YES NO DUCT SMOKE DETECTOR 4REA(S.E.) ✓ FIRE DAMPER(S) 3' -2" ✓ SMOKE DAMPER(S) 3' -1" ✓ FIRE RATED ENCLOSURE 51-4 34 ✓ F.RATED R/CEILING ASSEMBLY 18.61 ✓ FIRE STOPPING VOLTPH. -CY ■ SMOKE CONTROL -- D L WINDOW SCHEDULE TYPE WIDTH HEICs1.4T 4REA(S.E.) SH 13 1' -6" 3' -2" 2.54 SH 24 3' -1" 4' -2" 13.00 51-4 34 4' -5 41-2" 18.61 SPLIT SYSTEM - OUTDOOR UNIT SC4- 4EDULE 4/1111MMEMNII Bil II SYSTEM NO. SERVICE ~NMI SOOLING CAPACITY SEER ELECTRICAL REFRIG. P,P11 D'M�NS'UNS(IN) H W WEIGHT (LBS) ANEW MANUFACTURER MODEL TOTAL BTU/HR SENSIBLE 1=3TU/HR VOLTPH. -CY LIQUID SUCTION -- D 1 WHOLE APARTMENT 22600 16600 13.0 208/230 -1 -60 3/8 " 3/4 " 21 43 31 55 RHEEM RAMD- O24JDZ SYSTEM NO. SERVICE UJNOLE APARTMENT PROVIDE (2) 2 "X2 "XI" U- CHANNEL GA. 18 FASTENED TO THE PLENUM W/ (2) 4 "X2" SCREWS WITH WASHERS. - FACTORY INSTALLED CIRCUIT BREAKER. 63/8" OD LIQUID LINE THROUGH ATTIC TO C/U. 03/4" OD SUCTION ------ THROUGH ATTIC TO C/U, INSULATED WITH ARMAFLE 3/4 "x1/2 ". SUPPLY AIR (CFM) 800 EXT. S.P. I.W.G. 02 NEOPRENE PAD (TYPICAL) SPLIT SYSTEM - INDOOR UNIT SCHEDULE HEATING KW 5.0 PLEN A /1-4 m'O DRAI VENT. ELECTRICAL VOLT.P1.-CY 208/230 -1 -60 4 "min. ATTIC AIR HANDLER INSTALLATION n.t.s. PROVIDE (2) 1" GE20 TIE DOWNS AROUND THE C/U's CABINET TO SLAB BOLTED W/ (4) 1 -1/2" EXPANSION BOLTS. 4" CONCRETE SLAB. d . 4 a a CONCRETE PAD CONDENSER UNIT MOUNTING DETAIL. n.t.8. AMPS. CEILING PROVIDE 4" CLEARANCE AROUND A /H. REMOVABLE PERFORATED CAP PROVIDE A FLOAT SWITCH IN DRAIN PAN. NEOPRENE PADS .3/8" OD DRAIN LINE 23 "W x 22 "H x 23 "L THROUGH ATTIC TO ALUMINUM STAND SOIL AREA, INSULATED. I SECURE TO FLOOR SLAB THRU ANCHOR c:.:7:77 BOLTS. DIMENSIONS( IN) 14 35 14 22 WE IG1-4T (LBS) 81 MANUFACTURER RHEEM APAR 46 "FLEX BED ROOM 011114k0000 KITCHEN 140CFM 10"X6" 1' "FLEX DINING ROOM i 4 "FLEX / / / I40CFM 10 "X6" LIVING ROOM UTILITY BEDROOM I40CFM 10 "X6" 10 "x10" WALL TYPE RETURN GRILLE $4 "FLEX 40CFM — 8"X4" 10 "xl WALL TYPE RETU GRILLE R1-5A1-1M24114 APT. • 2 MODEL SN 24 C > PROPERTY LINE: >10' -0" N.T.S. 2(SH 24) 1IVAC NOTES: -ALL DUCTWORK TO BE R -6. -ALL DIFFUSERS ARE CEILING TYPE. -DRAIN PUMP INSTALLED BY MANUFACTURER RECOMMENDATIONS. 51-4 34 SECOND FLOOR PLAN - MECHANICAL scale: 1/4" = 1 -0" CONDENSER UNIT ON GROUND FLOOR ANCHORED TO CONCRETE SLAB. SEE DETAIL. REFRIGERANT AND DRAIN LINES. SEE A/1-4 INST. DETAIL. 51-4 24 5N 24 4 12 GE. HANGER WIRE 1-1/2"x26 GE. STRAP HANGERS AT 5' MAX. SEE PROJECT - FOR SIZE FLEXIBLE DUCT HANGERS n.t.s. (TYPICAL) n a N 11 ) '41V MZMEWn BY C C X -- WOOD BEAM POWER ACTUATED PIN L 2_ north / Genera 1 Notes 1 , c tY ( ALL 0(n6) Z u.--t c t 1>Ll O _1 aim E Revision /Issue z N v o cc Q t., N o U. .� dcNik \a.m. 1 1 1 Rhvac - Residential & Light Commercial HVAC Loads ERA Technical Services Miami, FL 33177 Project Report General Project Information Project Title: Project Date: Client Name: Client Address: Client City: Company Name: Company Representative: Company Address: Company City: Company Phone: Company Comment: Design Data Reference City: Daily Temperature Range: Latitude: Elevation: Altitude Factor: Elevation Sensible Adj. Factor: Elevation Total Adj. Factor: Elevation Heating Adj. Factor: Elevation Heating Adj. Factor: Winter: Summer: New Split System A/c 05 -15 -2006 Gerry Benson 736 Northeast 92nd St. Apt. Miami Shores, FI. 33138 Air 4 Less Air Conditioning Mr. Luis Carvajal 2523 Northwest 27 Ave. Miami, FI. 33142 305 - 637 -2000 Check Figures Total Building Supply CFM: 800 Square ft. of Room Area: 949 Volume (ft of Cond. Space: 7,779 Building Loads Total Heating Required With Outside Air: Total Sensible Gain: Total Latent Gain: Total Cooling Required With Outside Air: 25 10 1.000 1.000 1.000 1.000 1.000 13,793 Btuh 16,294 Btuh 1,977 Btuh 18,271 Btuh Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Elite S aftA are Devcloarr.e it, 1.1c. New S7't System .1/c Pagq 1 #2 Miami, Florida Low Degrees ft. Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference 48 0 50 72 19 92 78 50 75 58 CFM Per Square ft.: Square ft. Per Ton: Air Turnover Rate (per hour): 0.843 524 6.2 13.793 MBH 89 % 11 % 1.52 Tons (Based On Sensible + Latent) 1.81 Tons (Based On 75% Sensible Capacity) Tuesday, May 16, 2006, 11:43 AM Rhvac - Residential 8 light Commercial HVAC Loads Elite .1 oftxare Dev .)Ic pm( nt, lac. New S�'it System A/c ERA Technical Services System Miami, FL 33177 System 1, Zone 1 Summary Loads (Average Load Procedure for Rooms) Area Sen Lc.t Sen Tcta' , Quan Loss Gain amain G3ir•. 3,196 0 3,9:'0 3,920 Zone Loads Total Heating Required: Total Sensible Gain: Total Latent Gain: Total Cooling Required: Component 'Description 1A -cm -o: Glazing - Single pane, operable window, clear, 104.8 metal frame no break, ground reflectance = 0.23, outdoor insect screen with 50% coverage, light color closed blinds with 50% coverage, u -value 1.27 21 0 0 1 <g 139 110: Door -Solid Core 14E -0 -8c: Wall -two courses brick, brick on concrete or 8 658.6 6,134 0 4,9:52 P: ,932 inches concrete, 8 inches of 140# concrete with no board insulation 0 1,132 1,132 14E -0 -8c: Part-two courses brick, brick on concrete or 8 231.6 0 inches concrete, 8 inches of 140# concrete with no board insulation 16B -0: Roof /Ceiling -Under attic or knee wall, Vented 948.6 1,116 0 2,603 2,603 Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R -0 insulation Subtotals for structure: 10,446 0 12,726 12,726 People: 690 900 1,590 P 3 0 1,200 1,200 Equipment: 0 0 0 Lighting: 0 0 0 0 Ductwork: Infiltration: Winter CFM: 79, Summer CFM: 29 2,087 1,120 533 1,653 System 1, Zone 1 Load Totals: 12,533 1,810 15,359 17,169 Check Figures — -- — — Supply CFM: 800 CFM Per Square ft.: 0.843 Square ft. of Room Area: 949 Square ft. Per Ton: 560 Volume (ft of Cond. Space: 7,779 Air Turnover Rate (per hour): 6.2 Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. 12,533 Btuh 12.533 MBH 15,359 Btuh 89 % 1,810 Btuh 11 % 17,169 Btuh 1.43 Tons (Based On Sensible + Latent) 1.69 Tons (Based On 75% Sensible Capacity) Tuesday, May 16, 2006, 11:43 AM Rhvac - Residential & Light Commercial HVAC Loads ERA Technical Services Miami, FL 33177 System 1 Room Load Summary Htg Htg Run Run Area Sens Nom Duct Duct SF Btuh CFM Size Vel Room No Name -- -Zone 1 - -- 1 Second Floor Apartment AED Excursion Duct Loads 1,260 System 1 total 949 13,793 163 Cooling System Summary Cooling Sensible /Latent Tons Split Net Required: 1.52 89% / 11% Recommended: 1.81 75% / 25% Actual: 1.88 73% / 27% Equipment Data Type: Model: Brand: Efficiency: Blower CFM: Sound: Heating System Sensible Btuh 16,294 16,294 16,600 Clg Sens Btuh 949 12,533 163 7 -0 0 15,359 1,810 741 800 138 797 iti7 16,294 Cooling System SPLIT SYSTEM A/C RAM D -024J DZ RHEEM 13.0 800 Capacity: 22600 Sensible Capacity: n/a 16,600 Btuh Latent Capacity: n/a 6,000 Btuh Elite Cof:rware Devalc.pnient, inc. New stem A/c PaSa Clg Lat Btuh 1,977 Latent Btuh 1,977 5,431 6,000 c,g Ai; Nom C`=M CFM 741 800 Total Btuh 18,271 21,725 22,600 Tuesday, May 16, 2006, 11:43 AM