Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
716 NE 92 St (5)
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 4 7-71 Job Address 7/6 / (/i 92 r Tax polio// 3Z04.- V ? Legal Description Owner / Lessee / Tenanto4ortes?4 ?.A Owner's Address W s- / VLZ "I � Phone 499 Contracting Co. 4 44 i .�c�� � ��` �dt.4-iAddress 7'5'0 A/w 40 Y�7 ` / A• )Ef Qualifier C. 4 " ( J, 4 Phone ,S 72 )c1> A/ State if zY if Municipal # Competency # Ins .Co v r9 e CeS • ./-�0N. 4•s. Signatur Date: APPROVED: Zoning Master Permit li gYl &" Architect /Engineer Address Bonding Company Address Mortgagor Address Permit Type(circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION Ce 5 — O /`k ' iP/1ct/ 9 /e AA 4 crowv diet Square Ft. Estimated Cost(value) 7i O O WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construc on and zoning. Furthermore, I authorize the above-named Aontractor to do the work stated. Atftje or Co .._ L P _ -- Dr Notat�y. fas, pArO,g - Condo Presiden My l p i :s�Ihiil Ig � piS€riAg Pr�Ekl E L /�ry My Commission Ex ;p t TH?U CEPfLn "AL INS. WM. eQV( � / / V l� I �� E L. i ** * * * * * * * * FEES: PERMIT 1a RADON C.C.F. Fire Buildin Mechanical Plumbing * Signature of • yractor or Own e ••' •er Da te:. 4, /7 9s Notary as to ConttfklistfoRUBD%C DHieterPBti i4*r MISS QN EXP. "�•' / * Dom•_ * * ** NOTARY TOTAL DUE �✓ V P J Other , Electrical Engineering Inspection Number: INSP -20060 C L Permit Number: RF -6 -06 -1616 Inspection Date: 08/03/2006 Inspector: Grande, Claudio Owner: Job Address: Project: <NONE> CONDO, SHORES PLAZA EAST 726 92 Street NE Miami Shores Village, FL 33138- Contractor: KAWALEK ROOFING, INC Building Department Comments Wednesday, August 2, 2006 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 E, 03 C c1 Block: Permit Type: Roof Inspection Type: Final Roof Work Classification: Roof - New Phone Number Parcel Number 1132060440001 Lot: Phone: 786- 277 -9540 Page 1 of 2 Inspector Comments Passed Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Number: INSP -20060 C L Permit Number: RF -6 -06 -1616 Inspection Date: 08/03/2006 Inspector: Grande, Claudio Owner: Job Address: Project: <NONE> CONDO, SHORES PLAZA EAST 726 92 Street NE Miami Shores Village, FL 33138- Contractor: KAWALEK ROOFING, INC Building Department Comments Wednesday, August 2, 2006 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 E, 03 C c1 Block: Permit Type: Roof Inspection Type: Final Roof Work Classification: Roof - New Phone Number Parcel Number 1132060440001 Lot: Phone: 786- 277 -9540 Page 1 of 2 Inspection Date: 07/21/2006 Inspector: Desharnis, George Owner: Job Address: 726 92 Street NE Project: <NONE> Contractor: KAWALEK ROOFING, INC Building Department Comments Thursday, July 20, 2006 Miami Shores Village, FL 33138- Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone X052715 Fax: (305)756 -8972 Inspection Number: INSP -22854 Permit Number: RF -6 -06 -16161 r - ( � rl � i �l I r ,J CONDO, SHORES PLAZA EAST Block: Permit Type: Roof Inspection Type: Tin Cap Work Classification: Roof - New Phone Number Parcel Number 1132060440001 Lot: Phone: 786 - 277 -9540 Page 1 of 2 Infractio Passed Comments TIN CAP SPACEING True Passed Inspector Comments 7 `�, `, e V es 414-7-1'^---------,..i -7......- 0,2 / ci Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Date: 07/21/2006 Inspector: Desharnis, George Owner: Job Address: 726 92 Street NE Project: <NONE> Contractor: KAWALEK ROOFING, INC Building Department Comments Thursday, July 20, 2006 Miami Shores Village, FL 33138- Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone X052715 Fax: (305)756 -8972 Inspection Number: INSP -22854 Permit Number: RF -6 -06 -16161 r - ( � rl � i �l I r ,J CONDO, SHORES PLAZA EAST Block: Permit Type: Roof Inspection Type: Tin Cap Work Classification: Roof - New Phone Number Parcel Number 1132060440001 Lot: Phone: 786 - 277 -9540 Page 1 of 2 LATE MORNING lnfractio Passed Comments TIN CAP SPACEING True Passed i Inspector Comments T Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid until Y Inspection Number: INSP -22637 Permit Number: RF -6 -06 -1616 Inspection Date: 07/19/2006 Inspector: Desharnis, George Owner: CONDO, SHORES PLAZA EAST Job Address: 726 92 Street NE Project: <NONE> Miami Shores Village, FL 33138- Contractor: KAWALEK ROOFING, INC Building Department Comments Tuesday, July 18, 2006 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Permi Inspectio Work Classificati Phone Number Parcel Number 1132060440001 Lot: Phone: 786 - 277 -9540 Page 1 of 2 Inspection Number: INSP -22752 Permit Number: RF -6 -06 -1616 Inspection Date: 07/20/2006 A2 0 VET Owner: CONDO, SHORES PLAZA EAST Inspector: Desharnis, George Job Address: 726 92 Street NE Project: <NONE> Wednesday, July 19, 2006 Miami Shores Village, FL 33138- Contractor: KAWALEK ROOFING, INC Building Department Comments Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Permit Type: Roof Inspection Type: Tin Cap Work Classification: Roof - New Phone Number Parcel Number 1132060440001 Lot: Phone: 786- 277 -9540 Page 1 of 2 Infractio Passed Comments TIN CAP SPACEING True Passed Inspector Comments • 40/ Failed Correction Needed Re- Inspection Fee ($ ?5) No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Number: INSP -22752 Permit Number: RF -6 -06 -1616 Inspection Date: 07/20/2006 A2 0 VET Owner: CONDO, SHORES PLAZA EAST Inspector: Desharnis, George Job Address: 726 92 Street NE Project: <NONE> Wednesday, July 19, 2006 Miami Shores Village, FL 33138- Contractor: KAWALEK ROOFING, INC Building Department Comments Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Permit Type: Roof Inspection Type: Tin Cap Work Classification: Roof - New Phone Number Parcel Number 1132060440001 Lot: Phone: 786- 277 -9540 Page 1 of 2 Inspection Number: INSP -22752 Permit Number: RF -6 -06 -1616 Inspection Date: 07/20/2006 Inspector: Desharnis, George Owner: CONDO, SHORES PLAZA EAST Job Address: 726 92 Street NE Miami Shores Village, FL 33138- Project: <NONE> Contractor: KAWALEK ROOFING, INC Building Department Comments Wednesday, July 19, 2006 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Permit Type: Roof Inspection Type: Tin Cap Work Classification: Roof - New Phone Number Parcel Number 1132060440001 Lot: Phone: 786 - 277 -9540 Page 2 of 2 Infractio Passed Comments TIN CAP SPACEING True Passed Inspector Comments Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Number: INSP -22752 Permit Number: RF -6 -06 -1616 Inspection Date: 07/20/2006 Inspector: Desharnis, George Owner: CONDO, SHORES PLAZA EAST Job Address: 726 92 Street NE Miami Shores Village, FL 33138- Project: <NONE> Contractor: KAWALEK ROOFING, INC Building Department Comments Wednesday, July 19, 2006 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Permit Type: Roof Inspection Type: Tin Cap Work Classification: Roof - New Phone Number Parcel Number 1132060440001 Lot: Phone: 786 - 277 -9540 Page 2 of 2 Inspection Number: INSP -20059 Permit Number: RF -6 -06 -1616 Inspection Date: 07/18/2006 Inspector: Grande, Claudio Owner: CONDO, SHORES PLAZA EAST Job Address: 726 92 Street NE Miami Shores Village, FL 33138- Project: <NONE> Contractor: KAWALEK ROOFING, INC Building Department Comments Monday, July 17, 2006 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Permit Type: Roof Inspection Type: Tin Cap Work Classification: Roof - New Phone Number Parcel Number 1132060440001 Lot: Phone: 786 - 277 -9540 Page 1 of 2 G Passed Inspector Comments _ Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Number: INSP -20059 Permit Number: RF -6 -06 -1616 Inspection Date: 07/18/2006 Inspector: Grande, Claudio Owner: CONDO, SHORES PLAZA EAST Job Address: 726 92 Street NE Miami Shores Village, FL 33138- Project: <NONE> Contractor: KAWALEK ROOFING, INC Building Department Comments Monday, July 17, 2006 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Permit Type: Roof Inspection Type: Tin Cap Work Classification: Roof - New Phone Number Parcel Number 1132060440001 Lot: Phone: 786 - 277 -9540 Page 1 of 2 Inspection Number: INSP -20057 Permit Number: RF -6 -06 -1616 Inspection Date: 07/18/2006 Inspector: Grande, Claudio Owner: CONDO, SHORES PLAZA EAST Job Address: 726 92 Street NE Miami Shores Village, FL 33138- Project: <NONE> Contractor: KAWALEK ROOFING, INC Buildinn Department Comments Monday, July 17, 2006 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Sill 1 8 En Block: Permit Type: Roof Inspection Type: Hot Mop Work Classification: Roof - New Phone Number Parcel Number 1132060440001 Lot: Phone: 786 - 277 -9540 Page 1 of 2 Ve:„ Passed Inspector Comments &tat0 5keel a ,� Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Number: INSP -20057 Permit Number: RF -6 -06 -1616 Inspection Date: 07/18/2006 Inspector: Grande, Claudio Owner: CONDO, SHORES PLAZA EAST Job Address: 726 92 Street NE Miami Shores Village, FL 33138- Project: <NONE> Contractor: KAWALEK ROOFING, INC Buildinn Department Comments Monday, July 17, 2006 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Sill 1 8 En Block: Permit Type: Roof Inspection Type: Hot Mop Work Classification: Roof - New Phone Number Parcel Number 1132060440001 Lot: Phone: 786 - 277 -9540 Page 1 of 2 Inspection Number: INSP -20056 Permit Number: RF -6 -06 -1616 Inspection Date: 07/17/2006 Inspector: Grande, Claudio Owner: CONDO, SHORES PLAZA EAST G ! C'�.?��3 Job Address: 726 92 Street NE Miami Shores Village, FL 33138- Project: <NONE> Contractor: KAWALEK ROOFING, INC Building Department Comments Friday, July 14, 2006 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Permit Type: Roof Inspection Type: Tin Cap Work Classification: Roof - New Phone Number Parcel Number 1132060440001 Lot: Phone: 786- 277 -9540 Page 2 of 2 Infractio Passed Comments TIN CAP SPACEING True l ` Passed DC0 Inspector Comments l C60 TX- •(x-c Q d/ -� T z 3/ yttanr, 1 _. / ( Dee - - 5 EoLezeZ Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Number: INSP -20056 Permit Number: RF -6 -06 -1616 Inspection Date: 07/17/2006 Inspector: Grande, Claudio Owner: CONDO, SHORES PLAZA EAST G ! C'�.?��3 Job Address: 726 92 Street NE Miami Shores Village, FL 33138- Project: <NONE> Contractor: KAWALEK ROOFING, INC Building Department Comments Friday, July 14, 2006 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Permit Type: Roof Inspection Type: Tin Cap Work Classification: Roof - New Phone Number Parcel Number 1132060440001 Lot: Phone: 786- 277 -9540 Page 2 of 2 b j ok, g- = soz1- yViiaml Shores Village 3P N � Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 BUILDING PERMIT APPLICATION B Y:. FBC 2004 Owner's Address 1 7 1- 1-5 1) .3 r City t t I &r' t 11 O Y`P.._S State FL- Tenant/Lessee Name Job Address (where the work is being done) Pio,6ox 53)0s) Value of Work For this Permit $ 15 000 Tel: (305) 795.2204 Fax: (305) 756.8972 !i_i(i Permit No Master Permit No. Permit Type (circle): Building 1✓Tectrical Plumbing Mechanical (Fee Simple Titleholder) .S hureS P1&ZA E }. C o Y� d � Owner's Name Fee Sim le Titleholder Phone # r7 Ng q3. hd st Zip 33 L Phone # Contractor's Company Name J<oovek.l e R P O 4 I r9 Phone # Contractor's Address Architect/Engineer's Name (if applicable) Phone # 305 r1.5'L) -o 19/ Square / Linear Footage Of Work: 53 0 305 159 q0 69 City Miami Shores Village County Miami -Dade Zip FOLIO / PARCEL # Is Building Historically Designated YES NO City IV 110.►�VfJ( f State I�� Zip 33 / Qualifier Name P0., ....1 eJ< Phone # State Certificate or Registration No. Certificate of Competency No. 6 13 B-51)° ' f 0 `13 6 Type of Work: ['Addition ❑Alteration [New ["Repair/Replace ❑ Demolition Describe Work: -- feo r v4 e $ i.s`l' 1 h o --► a-}- g mve) ro o- j r -t-a ) a" ins l a�-e d b wA 1 -p roof Submittal Fee $ Q7 Permit Fee $ jJ i ' ' ' CCF $ CO /CC Notary $ Training/Education Fee $ Technology Fee $ Scanning $ Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ See Reverse side -3 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Sign: Print: Signature CeO�lpy� -40 Owner or Agent Contractor The foregoing instrument was acknowledged before me this O( The foregoing instrument was acknowledged before me this s day of lot , 20 b( , by ! (t1'I1ig ! (jeoI 77 t5 , day of , 20 00 , by who is personally known to me or who has produced I /• P4u2f'S who is °� ^ ^ ° " > ^ ^• As identification and who did take an oath. NOTARY PUBLIC: My Commission Expires: APPLICATION APPROVED BY: (Revised 02/08/06) MONICA LISSETH DIAZ MY COMMISSION # � 8 9 5 B mu Nctary Public Underwriters Signature NOTARY PUBLIC: Sign: P rint: MONICA LISSETH DIAZ MY COMMISSION # DD 483995 My Commission Expires: me or who has produced as identification and who did take an oath. Plans Examiner Engineer Zoning Issue Date: 6/15/2006 Owner's Name: SHORES PLAZA EAST CONDO Permit Type: Roof Work Classification: Roof - New Job Address: 726 92 Street NE Additional Information Miami Shores Village, FL 33138- Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Permit Expires: 12/11/2006 Contractor(s) KAWALEK ROOFING, INC Phone 786 - 277 -9540 Primary Contractor Yes Comments: TEAR OFF EXISTING FLAT GRAVEL ROOF; INSTALL W/H A NEW 2" INSULATED BUILT -UP ROOF SYSTEM Type of Work: Re -Roof Additional Info: Classification: Residential In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. Fees Due CCF Education Surcharge Notary Fee Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $45.00 $15.00 $5.00 $375.00 $6.00 $9.40 $455.40 Building Department File Copy Applicant Signature Parcel #: Block: Section: Permit Status: APPROVED Permit Number: RF -6 -06 -1616 Phone: 1132060440001 Lot: PB: Total Square Feet: 5200 Total Valuation: $ 75,000.00 Required Inspections Tin Cap Hot Mop Tile In Progress . Up Lift Report Final Roof Invoice Number R F - 6 - 06 - 25245 Total: Amt Due $455.40 iii 6 1 � " el- I Amt Paid NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county. AND THERE MAY BE ADDITIONAL PERMITS REQUIRED FROM OTHER GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT DISTRICTS, STATE AGENCIES, OR FEDERAL AGENCIES . 2FC,- « lam • • ••• • • • ••• ROOF ASSEMBLIES AND ROOFTOP S3 pt3 U*S ; ; ;'. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • eforjdi Bpil Edition 20 .. . . ... .... Mi lacity Harricans Zons U+rif•rr Permit Applicati • ••• • • • • • • • • • • • • (Ma• •• iv 0 • • • ster Permit No. • Process No. • Contractor's Name y� J Job Address r ig b 1 v E 1v1 ct ❑ New Roof • • Section A (General Information �f ROOF CATEGORY L� Low Slope ❑ Mechanically Fastened Tile ❑ Asphaltic ❑ Metal Panel/Shingles Shingles ❑ Prescriptive BUR -RAS 150 ROOF TYPE 1iReroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) S9.00 Steep Sloped Roof Area (SF) P nimlo C -:>PT S Q E An =tam AND f1MS./ rro is ❑ Mortar /AdhesiveSe ❑ Wood Shingles /Shakes ❑ Repair ❑ Maintenance eJ Shwzo V5 c:r bY DAM T B 0 Total (SF) 50.00 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 45 1 4 t 1 g 35 1 (3 9 15.32 FLORIDA BUILDING CODE — BUILDING rrPYj Pfcr mac App 133gj • • ••• • • • ••• • • • • • • • • • • • • • buil1lipg Code Edition 2004 High Velocity Hurricane Zone Uniform Permit Application Form • ••• • •••• •••• • • • • • • • • • • Fill in Specific Robf ASsemisW Corhponants • Fastener Spacing for Anchor /Base Sheet and Identify Manufacturer Attachment (If a component is npp ugecl, ideptityas "f .. ••• • .•0:11 • System Manufacturer � • • • Field: q .0.@ Lap, # Rows @ ° oc • • ••• •• q Perimeter. b -0c, Lap, # Rows q @ b ° oc Corner t 4 ° oc @ Lap, # Rows L I @ q ° oc Number of Fasteners Per Insulation Max. Design Pressure, From the Specific NOA Board System: Field: Perimeter Comer NOA No 03-05.01 S : 6 : :Fectition CJ l.` §(dped Roof System? Design Wind Pressures, From RAS 128 or Calculations: Pmax(5 Pmax2T S 913 prn,,a + `1 5/' wood GaGauge/Thickness: s ) Slope: 0 Anchor/Base Sheet & No. of Ply(s): I PI y b &, S C Deck: Type: -°.sat s cli K Si IV(•1 15 n rI n `a/g n a h Ca Insulation Base Layer. (A, i 1 Base Insulation Size and Thickness: q XL x aG l y Base I la "on f Material: Top Insulation Layer G 1 shr ec Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s) & No. of Ply(s) ' I be 1'4SS Ply P Material: T o p Ply: £P F I i 1 filer J Cep .heeF Top Piyps rrI t Surfacing: Illustrate Components Noted and Details as Applicable: Woodbiocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. 4 s FT. FT. • Parapet Height a ®' Mean Roof Height /L1-ro.1 1 `�czpered a - .501'n6iAlci‘ gpard MT d bkcP 6heei- I. Aesthetics- Workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane one) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be ad essed as part of the agreement between the owner and the contractor. / ' 2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Build' g Code. (The roof deck is usually concealed prior to removing the existing roof system). CA ,I rnon f 3. Commas Roofs: Cam roofs are those which have no visible delineation between neighboring nits (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. • • ••. • • • ••• •. •• • • • • •• •• • • • • • • • • • • • • • • • •.• • • - • • • • • • • • • • • • ••• • • • • ••• • • • • • • •• • • • •• • • • • • .. • • • • • : •: SECTION I524 HIGH VELOCITY HL' It'_'r►.YE.4ONE$ RE OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS •• • • • •. ••• •• • 1524.1 As it pertains to this s et ;io of the roofing contractor to provide the owner with the required roofing permit, aad'td e&ptai t Co 114 awns? the content of this section.. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the fallowing items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been • explaygt 4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may with to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The Florida Building Code provides the optio f maintaining this appearance. 1-' 5. Ponding Water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural .engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the origun] roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overldaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordan with the Florida Building Code, Plumbing. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. ) wrter's/Agent s Sigr.arure Due Contractor's Signature •• •• •. • • • •• M I A M MADE lE 11111 BUILDING CODE C( 1PL44NCE,QFFIC1f.(13(rCO) • . PRODUCT CONTROL 'D1\ SOO. • • • • • • • ••• • • • • • • • • • • • • • • • • ••• • • • NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation • . 1361 Alps Road Wayne, Ni 07470 • • • • • ••• • •••••• • • • • • • • • • ••• O. • • •••••• ••• • • • • • • •• ••• •• • • • • • • • • • • • • • • ••• •• • MM'l-9M)I COUNTY, 1L0 t1Dn MEMO-DAL)[ t'L.ACL1 R 13UIL01NG 140 WEST 1''LAGLER STREET, SUITE1603 • MIAMI, FLO1tII)A 331301563 (305) 375 -2901 FAX (305) 375.2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. • The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Cornmittee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (A111). This NOA shalt not be valid after the expiration date stated below. The Miami-Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. if this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AIU may inunediately revoke, modify, or suspend the use of such product or in:aerial within their jurisdiction. BORA reserves the right to revoke this acceptance, it it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: (: AF Conventional Built -Up Roof System for Wood Deck. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Yroduct Control Approved ", unless otherwise noted herein. grer-06—votco RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. T1:RIVl1NA'I'1ON of this NOA will occur after the expiration date or it there has been a revision or change in the materials, use, and /or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miarni-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection al the job site at the request of the Building Official. This NOA renews NOA 002- 0408.09 and consists of pages 1 through 21. The submitted documentation was reviewed by Frank Zuloaga, RRC NOA Nu: 03- 050 :105 Expiration Date: 11 /04/08 Approval Date:10/23/ Page 1 °of 3'l r • • • • • • • • • • •• •• • • • • • • • • • • • • • • • • • • • • • • .ROOFING SYSTEM AP P R O V A L . • • Catetory Sub - Category: Product GAF Asphalt Concrete Primer (Matrix" 307 Primer) GAF Mineral Shield® Granules GAP WeatherCoat u Emulsion (Matrixt'`t Fibered 305 Emulsion) GAF Premium Fibered Aluminum Roof Coating (Matrix System Pro Aluminum Roof Coating Fibered 301) GAF Jetblack All Weather Plastic Cement (MatrixT't Standard Wet/Dry Roof Cement 204) RUBEROID® Modified Bitumen Flashing Cement Jetblack Premium Flashing Cement G AFGLAS® GAFGLAS #80 Ultima Base Sheet GAFGLAS Flex PlyT" 6 Dimensions 5, 55 gallons 60 lb. hags 5 gallons 1, 5 gallons 5 gallons 5 gallons 39.37" (t meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide ••• • • • • •. • • • • Rvofiag • • • . • •• • • • • • •• • 13t;�12 ... •••• • • ••• • Deck 'Fyne: Wood Maximum Design Pressure -75 psf •. • • • •• • ••. Fire Classification: • . l ee . t i � n e ; ra :l. ,urt i jittion. #1 • • • • •• • •• • • ••• • • • • • • TRADE NAMES OF'f RODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test S ASTM D 41 Asphalt concrete printer used to promote adhesion of asphalt in built -up roofing. ASTM D 1863 Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral Shield® Granules shall be used for flashing applications only. ASTM 1227 Surface coating for smooth surfaced roofs. 1, 5 gallons ASTM D 2824 Fibered aluminum coating. ASTM T) 3019 Refined asphalt blended with a mineral ASTM 1) 3409 stabilizer and fibers. Permits adhesion to wet and dry surfaces. ASTM 1) 4586 Fiber reinforced, polymer modified Flashing cement ASTM D 4586 ASTM D 4601 ASTM D4601 ASTM D 2178 Product Description Asphalt flashing Cement Asphalt impregnated and coated glass runt base sheet. Asphalt impregnated and coated, ftbergha.ss base sheet Type V1 asphalt impregnated glass felt w ith asphalt coating. NOA No: U3 050111.05 Expiration Date: 11/041U8 Approval Date:10/2 /03 Page 2 or 121 Product GAFGLAS Ply 40 • • • .J.37" 4: mr2er) : • :•• • wide • ••• . • • GAFGLAS® Mineral • 39.37' r r mete]; Surfaced Cap Sheet wide GAFGLAS© h132" �1 ;nee: • STRATAVENT® Eliminator Perforated GAFGLAS® Flashing GAFGLAS O STRATAVENT Pliminator Perforated Nailable RUBEROIDO SBS Heat - Weld'FM Smooth RUBEROID a SBS Heat- W Granule RUBEROID « SBS Heat - Weldtm 170 FR R1113ERO1D® SI3S Heat- WeIdTM PLUS RUBEROID® SBS Heat - Weld PLUS PR RUBEROlD® SBS Heat - We1d" 25 RUI3EROI1) Modified Base Sheet Ruberoid® 20 Ruberoid a Mop Granule • • ••• • • • ••• •• •• • • • •• •• • • • • • • • • • • • • • 'test • • • • • • • • • • • • • '• � • • • • • • • • bimeustons Spect hcation • • • • •• Fiberglass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. Various Asphalt coated glass fiber mat Clashing sheet available in three sizcs. ASTM D 4897 Fiberglass base sheet impregnated and D 3672 coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. ASTM D -6164 Non -Woven Polyester mat coated with polymer- modified asphalt and smooth surfaced. 1 meter (39.37 ") ASTM D -6164 Non -Woven Polyester mat coated with wide polymer modified asphalt and surfaced with mineral granules. . • • wide • • 39.37" (1 meter) wide 1 meter (39.37') wide 1 meter (39.37 ") wide 1 rneter (39.37 ") wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (I meter) wide Product Description ASTM 11 2178 Type IV asphalt ihnprcgnaled glass felt with ••••• asphalt coating. ASTM D 3909 Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. • • • • • • • • •• - •• ;As D 4897 :•• 1 Non -Woven Polyester neat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with tire retardant polymer modified asphalt and surfaced with mineral granules. ASTM D -6164 Non -Woven Polyester mat coated with polymer-modified-asphalt and smooth surfaced. ASTM D4601, Premium glass fiber reinforced SI3S- Type II, UL modified base sheet Type G2 BUR ASTM D 6163 SBS modified asphalt base sheet and ASTM D 5147 interply sheet reinforce with a glass fiber mat. ASTM D 6222 Non -woven polyester neat coated with ASTM D 5147 polymer modified asphalt and surfaced w ith mineral granules. ASTM D -6164 ASTM D -6164 ASTM D -6164 NOA Nu: 03 0503.0 Expiration Date: 11 /04108 Approval Date:1U /23103 Page 3af21 Product Ruheroid® Mop Plus • (Granule) • • • • • • • • RUBEROID MOP • Smooth •• •• R1113EROIDO MOP..: l70P'R RUBEROIDO MOP FR RU13EROIDO TORCH Smooth RUBEROIDO TORCH Granule RUI3EROID® 'TORCH PLUS (Granule) . RUI3EROIll O TORCH FR RUBEROID 170FR TORCH RUl3ERO1D® 30 RUBEROID® 30 FR RUBEROID ULTRACLAD® SBS RCBEROID® Dual FR • • ••• • • • ••• •• •• • • • • • • ••• •• • • Test • • • • • • • • • • • • : 1Lmaffssods : Sacification • • r-• • • . • ••• Product Description 39.37" (1 meter) ASTM D 6222 Non -woven polyester mat coated with •" •:vidi: •AST•1113 5147 polymer modified asphalt and surfaced with •' • • • • • • • • • • • • • • mineral granules. • •39.39" "(1 • meter) • ASTM' D • 6164 Non -woven polyester neat coated with wide ASTM D 5147 polymer- modified asphalt and smooth surfaced. • • • •• ••• •• :3 ;.37 " {1:intiteF) AS' I D 6164 • wide •• �AS TM D5147 39.37" (1 meter) ASTM i) 6164 Non -Woven polyester mat coated with fire wide ASTMD 5147 retardant polymer modified asphalt and surfaced with mineral granules. 39.37" (1 meter) ASTM D 5147 Heavy duty, polyester reinforced, asphalt wide modified bitumen rfiembrane, smooth surface. 39.37" (1 meter) ASTM D 5147 Asphalt impregnated, coated felt, surfaced wide with mineral granule. 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) Wide 39.37" (1 meter) wide 39.37" (l meter) wide 39.37" (1 meter) wide 39.37" (1 meter) Wide Nun -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. ASTM D 6222 Heavy duty, polyester reinforced, asphalt ASTM D 5147 modified bitumen membrane, granule surface ASTM D 6222 Heavy duty, polyester reinforced, coated ASTM D 5147 with fire retardant asphalt modified bitumen membrane, granule surface. ASTM D 6222 Heavy duty, polyester reinforced, coated ASTM D 5147 with fire retardant asphalt modified bitumen membrane, granule surface. ASTM D 6163 Non -woven fiberglass mat coated with ASTM D 5147 polymer modified asphalt and surfaced with mineral granules. ASTM D 6163 Non -woven fiberglass mat coated with fire ASTM D 5147 retardant polymer modified asphalt and surfaced with mineral granules. ASTM D 6298 Woven fiberglass mat coated with Polymer ASTM D 5147 modified asphalt and surfaced with aluminum, copper ur stainless steel foil. ASTM D 6164 Non -woven polyester and fiberglass mat ASTM D 5147 coated with file retardant, polymer modified asphalt and surfaced with mineral granuldes. NOA No: 03- 0507.05 Expiration Date: 11104U8 Approval Date:10 /2J/03 Page 4 Product Vent Stacks (metal and RUBEROII) MOD Asphalt, Asphalt I.. Nc Asphalt P Tile -Mate Base Sheet Tile -Mate Cap Sheet .. • •. • • • • .• • • plastic) • • • • • • • • • • • • • • • • ... • GAF Aluminum 5701 ons .Emulsion GAF Aluminum Root. • • Paint (Matrix ® System Pro Aluminum Roof • • Coating Fibcred 302) GAF Built -Up Roofing 1001b. cartons, Asphalt bulk Shingle -Mater t Underlayment TopCoat® Surface Seal SB (Mauix 602 SB Coating) GAP WeatherCote( MB+(Matrix 715 MB Coating) TopCeat MB-1-(Matrix 715 MB Coating) WeatherCutc'''''' (Matrix 531 WeatherCute© Elastorneric Flashing Grade) Matrix Low VOC Matrix 101 System Pro SBS Adhesive (Rubcruid ®MB) Matrix 201 System Pro SI3S Flashing (Ruberoid®MB) Matrix 102 Select SI3S Adhesive ... • • • ..• • •• •• • •• •Test • • • • D i me nsw n s � St c 5.4:111(14, : • •ASY" v1 D2824, ••• .•. . •Types • • • ••• ••• 6() Ib. kegs PA I00(A) • ggS'1'iiI D 1929 4'I! 1:D 635 • None Product Deserintion One way valve vent used to relieve built -up pressure within the roof system. GAF Vent Stacks are available in metal or plastic. Mineral colloidal bituminous emulsion with reflective aluminum flakes Non- fibered aluminum pigmented, asphalt roof coating ASTVI D312, Interply mopping and surfacing asphalt Types I, II, III and IV SEBS modified asphalt 39.37" (1 meter) ASTM D4601 Asphalt impregnated and coated, fiberglass wide base sheet 39.37" (1 meter) ASTM D 3909 Asphalt coated, glass fiber mat cap sheet wide surfaced with mineral granules. 4 sq. roll 30 lbs. 5 gallons 5 gallons 5 gallons 5 gallons 5 gallons 5 gallons ASTM D3019 5 gallons ASTM D3019 5 gallons ASTM D3019 Fiberglass reinforced shingle underlayment Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and tniaeral surfaced roofs. Surface coating for smooth surfaced and • mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Cold Applied Modified SEBS Asphalt Adhes ive Cold Applied Modified SEBS Asphalt Adhesive — Flashing Grade. Cold Applied Modified SEBS Asphalt Adhesive. NOA No: 03- OS01..05 Expiration Date: 11 /04/08 Approval Date:10 /23103 Page 5 of 21 Product • • (Rubcroid ©MT)) Math ix� 202 Select SBS flashiig Matrix 203 Standard Plastic Cement •• • Matrix 2.13 Gun Grade • • Plastic Cement • • M;tl 103 Cold Adhesive Matrix 303 Select Fibered Aluminum Matrix 304 Select Non - libered RUREROID® N'It dified . l:t it omen Adhesive AVPROV1;D INSULATIONS: C'YRC)X White Lttte Product Name GAFTEMI' isotherm R, RA, RN & Composite, EnergyGuard RA GAFI•EMP® Composite A & N • • ••• • • • • • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • •• • • (BNICA)C; AF 1.'EMPO Fiberboard (■Af Per GAFI'EMP GARCANT't''t (.;Ar1'L;MI' l'ermalite. Recover Board G;MM'TEMP GAFEL)GEtM Tapered t:dgc. Strip (BMCA) GAFI'EMP@ High Density Fiberboard 1!MCA F.nergyGuard, RA I1MCA. Composite 1inrrgyGuard, RA • • • • •• • • • • • • • • • • • 'Zest Dimensions Specification •• • • • • •• •• • • • • • • ra�lons•: ' 4S1M t)4586 6 . • • • • • ••• • 5 gallons ASTM D4586 • • • • •• •••• •• • • : • 5 gal?ratt. • :'AST D4586 • • • • • ••• •• • 5 gallons ASTM 1)3019 5 gallons 5 gallons 5 gallons Product Description Cold Applied Modified SEBS Asphalt Adhesive —Flashing Grade. Standard Plastic Asphalt Rooting Cement Standard Plastic Asphalt Roofing Cement Caulk Grade. Cold Applied Asphalt Adhesive. ASTM D 2524 Fibered aluminum coating. ASTM 1)2824, Non-liberal aluminum pigmented, asphalt Type 1 roof coating. ASTM D 3019 Fiber reinforced, rubberized Adhesive Type 11! TA0LE 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation with high density fiberboard or Permalite perlitc insulation. Fiberboard insulation. Perlite insulation board. Cut l ,etlite board 1'erlite recover board Tapered perlite board High density wood fiberboard insulation. Polyisocynurate foam insulation Potyisocynurate /wood fiberboard composite Polyisocyanurate foatn insulation Polyisocyanurate foam insulation Manufacturer (With Current NOA) GAF Materials Corp. GAF Materials Corp. GA1 Materials C.'orp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. BMCA BMCA Apache Products Co. Apache Products CC NOA Nu: 03 -0501_ .I15 Expiration Datt:: 11/01 J03 Approval Date:10 /23 1113 Page 6 u t=21 • ... • • • 00* .. •• • • • •• •• • APPROVED INSU1 't1 NS: ' •' 1 • : ••• • • • • 'I.'M3LE2 Product l;a`am .. ••. • • • • ACFaam E, TI & Cox s.te. ISO 95+ Polyisocyanurate foam insulation ISO 95+ Composite .. • • • • • Wood Fiber High Density Wood Fiberboard Perlite Insulation Dens Deck E'N1tG'Y -2 & E'NRG'Y-2 PLU S, UltraGard Gold FiberGlass Roof Insulation Structodek Multi -Max & FA Paroc Base Board Paroc Cap Board AI'1'ROVED FASTENERS: Fastener Number 1. 3. 4. 5. 6. Pe1} /periite ridged • . . • • ... • • insulation Product Nuriie GAFTLTE® (Drill -Tec ®) #12 Standard & #14 Heavy Duty Roofing Fastener GAFI'ITE® (Drill -Tec®) ASAP GAFTTTE® (Drill-Tec®) Base Sheet Fastener and Plate Galvaltune Plates (Drill - Tcc® Metal) Polypropylene Plates (Drill -Tec a Plastic) Dekfast Fasteners # l2, 01.4 & 1/15 • • Product Description • •• •• • • • • • • : • 1P31yisctydn:r4e foam insulation ••• • • .. ... .. • • Wood fiber insulation board Wood fiber insulation board Perlite insulation board Water resistant gypsum board Polyisocyanurate foam insulation Glass fiber/Mineral fiber insulation Wood fiber insulation board Polyisocyanurate roof insulation Rockwool insulation TABLE 3 Product Manufacturer Description Dimensions (With Current NOA) Insulation fastener for • GAF Materials Corp. steel, wood & concrete decks. Pre - assembled GAFTITE GAP Materials Corp. Fasteners and metal and plastic plates. Base sheet fastening GAF Materials Corp. assembly. Round galvalume stress 3" and 3'/" plates. Round polypropylene stress plates. Insulation fastener for wood, steel and concrete decks MVlanufacturer (With Current NOA) Atlas Energy Products Firestone Building Products, Inc. Firestone Building Products, Inc. generic generic generic G -P Gypsum Corp. Johns Manville Johns Manville Masonite. RMax, Inc. Partek, Inc. GAP Materials Corp. 3" and 31" GAF Materials Corp. Construction Fasten ers Inc. NOA No: 03.0501.0 Expiration Date: 11 /04/08 Approval Date:10 /23/03 Page 7 i. f 21 . •.• . APPROVED FAS'TteN€ltS • . • Fastener Number 7. Product • • • • .. • • • DekfastTIdx Plate •:. 8. Dekfast Locl�Pit; • • • . . • • ••• • • 9. #12 Roo fgl•rrFistino�s: 10. Metal Plate • • • • • • • •. • • 11. Gearlok Plastic Plate 12. Glasfast Fastener 13. Olympic Fastener #12 & *14 14. Olympic Fastener ASAP 15. Olympic Polypropylene 16. Olympic G -2 17. Olympic Standard 13. Insul -Fixx Fastener 19. Insu1 -Fix' S Plate 20. Iusul -Fixx P Plate 21. Tru -Fast 22. Tru -Fast Plates 23. Tru -Fast Plates • ... • •• • • • . • • • 'D4!LL 3 • Product • Pigscription • 00A 4alvaitir;e h. +c stress plate. Polypropylene locking D IaI� • : • lttsttlation Castener for • wood Galvaluute stress plate. • • • • Polypropylene round plate Insulation fastener assembly with recessed plastic plate Insulation fastener Pre - assembled Insulation fastener and plate Polypropylene plastic plate 3.5" round galvalume AZ55 steel plate 3" round galvalume A250 steel plate Insulation fastener for steel and wood decks 3" round galvalume AZ50 steel plate 3" round polyethylene stress plate Insulation fastener for steel and wood decks 3" round galvalume AZ55 steel plate Polyethylene plastic plate Dimensions 2 7/8" x 3 1 /3" 3" x 3 1/4" 3" round ITW Buildex Corp. 3" square 3 2" ITW Buildex Corp. Johns Manville 3.25" round 3.5" round 3" round 3" round 3" round 3" round 3" round Manufacturer (With Current NOA) Construction Fasteners Eric. Construction Fasteners Inc. ITW Buildex Corp. Olympic Manufacturing Group, inc. Olympic Manufacturing Group, Inc. Olympic Manufacturing Group, Inc. Olympic Manufacturing Group, Inc. Olympic Manufacturing Group, Inc. SFS /Stadler SFS /Stadler SFS /Stadler The Tru -Fast Corp. The Tru -Fast Corp. The Tru -Fast Corp- NOA Nu: 03- 0501.05 Expiration Date: 11 /04 Approval Date:10/23 / Page So • • • ... • • • •.• •. •• • • • •. •. • • • • • • • • • • • . • • • • • • ••• • • • • •EV1DENCE » • • • • • Test Ago rf .' • •: .• • • • • • • • • • • • • Factory Mutual Resarch•Corp.• • • Factory Mutual Rese tch o;p. • • • ••• • • • • • Factory Mutual Research Corp. PRI Asphalt Technologies, Inc. PRI Asphalt Technologies, Inc. 1RTofS.Fl. IRT of S. Fl. Vest Identifier• • • • • • •• • 1MR •19b• • 438A4AAM •LT. 339Q1 .41V1 •J.Z. OOAS.AM J.I.OD 1A8.AM J.I. 0Y9Q5.AM GAF -012 -02 -02 GAF- 020 -02 -01 02 -005 02 -014 Description Current Insulation Attachment Requirements Wind Uplift FMRC 44704 Wind Uplift FMRC 4470 - PA 114 Physical Properties ASTM D 4977 TAS 114 TAS 114 Date 01.01.96 07.02.97 01.08.98 07.09.99 07.29.94 04.01.98 11.06.01 02.01.02 01.18.02 03.22.02 NOA No: 03- 0507.05 Expiration Date:110 / Approval Date:1 U/Z 3/03 Page 9 cot 21 APPROVED ASSEMBLIES • ••• • • • ••• • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • ••• • • • • • • ••• • •• • • • • • • • • • • •• • • • • • Deck Type 1I:: ::' ',Mod; Ind: ed • • • �•. • • • • • • Deck Description: 19 or greater plywood or wood plank System Type A (1j;, gcltorhie :rrgartiFl ly fastened, all layers of insulation adhered with �131:iraver 3 bait • • • • • • • • • ••• • • All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation Layer (Table 2) Insulation Fasteners Fastener (When applicable: Steel plate only =S, platic plate only (Table 3) Density /ft =P) ACFoam -I, ENRGY 2, Isotherm R, E'NRG'Y 2 Plus,CAFTEMP Isotherm RA,% GAFTEMP Isotherm RN, GAFTEMP Composite, GAFTEMP Composite A, GAFTEMP Composite N, BMCA EnergyGuard, BMCA EnergyGuard Composite, EverGuard ISO, ISORoc, EnergyGuard RA, EnergyGuard RA Composite Minimum 1" thick N/A N/A BMCA High Density Wood Fiber, GAFTEMP® High Density Wood Fiber, GAFTEMP RecoverBoard, Wood Fiber, GAFTEMP® Fiberboard Minimum Y2'' thick N/A N/A Perlite, GAFTEMP® Permalite ®, Permalite Tapered, Paroc Minimum 3 /a" thick Fiberglas (Min. 15 /16" thick) N/A N/A N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20 -40 lbs/100 f1 Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS STRATAVENT® Eliminator Perforated laid dry or a layer of GAFTEMP® PERMALITE or wood fiber overlay board on all isocyanurate applications. Anchor sheet: GAFGLAS #80 Ultima'T" Base Sheet, STRATAVENT® Eliminator Perforated Nailable, RUBEROID Modified Base Sheet, RUBEROID® 20, RUBEROID SBS Heat- WeldThi Smooth or RUBEROID SBS Hcat -Weld 25 base sheet mechanically fastened as described below; Fastening Options: GAFGLAS® Ply 4 ®, GAFGLAS Flex Plyrm 6, GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General Limitation #7) NOA No: 03- 0501.05 Expiration Date: 11 /04/08 Approval Date:10/23 /03 Page 10 of 21 • • •.. • • • . •. . . .. • • • • • .. . • • • • • • • • • • • • • • • .. • • • . • • • • • • • • • • • G 'U`]ASCe Pry 40' GAFGLAS Flex PIyTM 6, GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with Drill -Tec (GAFTITE) #12 or • • . 424 Sct$ws and 3" PJatp o.c. in 3 rows. One row is in the 2" side lap. The • • • • • �he ro ass ggdally ip 4 approximately 12" o.c. in the field of the sheet. . . . .. . . . • fMaximum Design pressuse -45 psf, See General Limitation #7) GAFGLAS Flex P1yrM 6, GAFGLAS #75 Base Sheet or any of above Anchor k • • stets a s achad to,44ck with approved annular ring shank nails and tin caps at a • • f St • ueing of•9" o,c. at the 4" lap staggered and in two rows 9" o.c. in the • • field. TratAtni Resign Pressure — 52.5 psf, See General Limitation #7) g GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with Drill -Tec (GAFTTTE) #12 or #14 Screws and 3" Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Any of above Anchor sheets attached to deck approved annular ring shank nails and 3" inverted Drill -Tec (GAFT1TE) insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation 47) GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with Drill -Tec (GAF I1:1"E) #12 or #14 Screws and 3" Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure — 75 psf, See General Limitation #7) Base Sheet: (Optional) Install one ply of GAFGLAS® #75, GAFGLAS #80 Ultima Ultra Base Sheet, GAFGLAS STRATAVENT Eliminator Perforated, RUBEROID Modified Base Sheet, RUBEROID Mop Smooth, RUBEROID® 20 RUBEROID SBS Heat -Weld Smooth or RUBEROID SBS Heat -Weld directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 2040 lbs. /sq; (see General Limitation #4). Ply Sheet: One or more plies GAFGLAS PLY 4® GAFGLAS Flex Ply 6 sheet, #80 Ultima, k RUBEROID Mop Smooth or RUBEROID 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet adhered in ale full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. • Surfacing: (Required if no cap sheet is used) Install one of the following: 1. GAF Special Roofing Bitumen with an application rate of 20 lbs. /sq with an application rate of 1.5 gal. /sq.; or GAF WEATHER COAT® Emulsion (Matrix 305 Fibered Emulsion) with an application rate of 3 gal. /sq.; or GAF Premium Fibered Aluminum Roof Coating (Matrix System Pro Aluminum Roof Coating Fibered 301) with an application rate of 1.5 gal. /sq. 2. Asphalt flood coat at an application rate of 60 lbs. /sq. ± 20 %; plus gravel or slag with an application rate of 400 lbs. /sq. & 300 lbs. /sq., respectively. 3. Top Coat Surface Seal SB (Matrix 602 SB Coating), Top Coat MB Plus (Matrix 715 MB Coating), GAF WeatherCote or WeatherCote LOW -VOC applied at rate of 1 -1.5 gal /sq. Maximum Design Pressure: See Fastening above. NOA No: 03 0501.05 Expiration Date: 11/04/08 Approval Date:10/23 /03 Page 11 of 21 • • . • • . . • • • • • . • . • . . • • • . • . . • WOOD DECK SYStfil ;1141:FA'I:I01;1�'i: • 1 A slip sheet is required with Ply 4 and Flex Ply C when used as a mechanically fastened base or anchor sheet.. .. • • .. 2. Minimum wood deck. • • . , is lleckpr r i.Z • Yp%�Zt' .y''k�rrn board is acceptable to be installed directly over the • ,,, • • r ' G ENE RAI, LIMITSk1'[QN: • ••• 1. Fire classification Its m r pact f :this ad ep(ance, refer to a current Approved Roofing Materials Directory for life rittitlgs 15f tltis 2. Insulation inr.y be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the F;V']' range and at a rate of 20.40 lbs. /sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes arc acceptable for mechanical attachment. When applied in approved asphalt, panel sive shall be 4'x 4' maximum. 4. An overlay and /or recovery board. insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully propped. If no recovery board is used the base :hcet shall be applied using spot mopping with approved asphalt, 12" dia.meter mopped 8" ribbons in three rows, one at each sirlclap and one clown the center t edsheet allowi a continuous area of ventilation. Encircling of the strips is not acccptahlc. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall ire at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall be limited to a maximum, Cesign pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (PP) value of 275 lbf., as tested in compliance with Testing Application Standard 'I'AS 105. if the fastener value, as field- tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the niaxiururn design value listed within a .spccific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida IRegiste•rcd Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS (1)5 and calculations in compliance. with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall he increased for both insulation arid base sheet as calculated in compliance with Roofing Application Standard RAS 117. (When this limitation i s spcci fic,rlly :. 8• referred within this NOA, (general Limitation 119 will not be applicable.) All attacluneitt and sizing of perimc to milers, metal profile, and/or flashing; termination designs 2 • shall conform with Roofing Application Standard RAS 1.11 and applicable wind load rcga ireiilc fits. The eta- �cinun designed pressure limitation listed shall be applicable to all roof pressure zones i.e. field, perimeters, arid corners). Neither rational analysis, nor extrapolation shall be pc: alitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred Fvithin this NOA, Cenerul Limitation 117 will slot be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florid ] Code and Rule 913 -72 of the Florida Administrative Code. a END OF TII1S ACCEPTANCE NOA No: 03- 05U1.0S Fxpiratlon Date: 11/04/03 A pp ro vu l Date: 10123/03 Page21 Of21 s 4 {. Roofing Systems (T $ f UJ: Cv r$ined : • •' •: • • • • • • • • • • • GAFGLAS X80 Premium Base Sheet rnmy be :use4 in ••robs of the gllo 'ing sestet -s. • • ••• • • • ••• "GA: Flex Ply 6" is a suitable alternate to "GAFglas Ply 6". "GAFTEMP Perma(ite Recover Board" may be used in lieu of any perlite insulation in any of the following NC ltiftions • • •• ••• Class A :B -rta; • • ••• • • ••• Hot roofing asphalt, for use with orgSrye artcislass (rl s or mddifiedVtrtteji membranes. "Ruberoid Heat Weld " SBS roofing membraner may be used in lieu of "Ruberoid Mop" SBS products in any appiisabie clas. fi cagign. ••• ,• Classll• ••• • • • • •• •• Deck: C-13;32 •L ns li rte: • :.• . • • Insulation (Optional): One or mstt Ia,ers pellite,•wodiRller,•glass fiber. isocvanurate, urethane, perlite /isocvanurate composite, perlite/ urethane composite, wood fiber /isocvanurate composite, phenolic. am• thickness. Ply Sheet: Three or more layers Type GI "GAFGLAS Ply 4 " or "GAFGLAS Ply 6", hut mopped. 22. Surfacing: Gravel. Deck: C- 15/32 Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber. isocvanurate, urethane. perlite /isocvanurate composite, perlite urethane composite, wood fiber /isocvanurate composite, phenolic, any thickness. PIy Sheet: Three or more lavers Type G1 "GAFGLAS Ply 4" or "CAFCLAS Ply 6 ". Cap Sheet: One laver Type G3 "GAFGLAS Mineral Surfaced Cap Sheet". 3. Deck: \C Incline: 2 Insulation (Optional): One or more lavers perlite, wood fiber, glass fiber, isocvanurate, urethane, perlite /isocvanurate composite, perlite/ urethane composite, wood fiber /isocvanurate composite, phenolic, 2 in. max. Ply Sheet: Two or rnore layers Type GI "CAFGLAS Ply 4" or "GAF• CLAS Ply 6" Cap Sheet: One laver Type G3 ""GAFGLAS Mineral Surfaced Cap Sheet". 4. Deck \C Incline: 1/2 Insulation: One or two layers "Isotherm R ", 4 in. max, hot mopped. Ply Sheet Any LL Classified gavel surfaced Class A asphalt glass fiber mat system. 5. Deck: C -15/32 Incline: 1 Slip Sheet (Optional): Red rosin paper, nailed to deck. Base Sheet: One layer of Tvpe G2 "CAFGLAS #75 Base Sheet" (may be nailed). Ply Sheet: One or more layers of Type GI "GAFGLAS Ply 4" or GAFGLAS Ply 6'. Cap Sheet One layer of Type C -3 "GAFGLAS Mineral Surfaced Cap Sheer. 6. Deck: NC Base Sheet Incline: 3 - • - One layer of Type G2 "•GAFGLAS #75 Base Sheet"'. Plx Sheet: One or more layers of Type Cl "GAFGLAS Ply 4" or GAFGLAS Ply 6'. Cap Sheet: One layer of Tvpe C -3 "CAFCLAS Mineral Surfaced Cap Sheet". 7. Deck C -15/32 Insulation: Incline: 2 One or more layers perlite, glass fiber, isocvanurate, ure- thane perlite %isocvanurate composite, perlite /urethane composite, phe- nolic, 1.0 in. min (offset from plywood joints 6 in.). Base Sheet: One or more layers of Type CI, C2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). B Cap Sheet ' "GAFGLAS Mineral Surfaced Cap Sheet", hot mopped. Deck: C -15/32 Incilrte: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass Hl)ec isocyanurate, urethane, perlite / Lsocvanurate composite, perlite/ ctre composite, wood fiber /i anurate composite, phenolic, any y Base Sheet Two or mor: layers of Type G2 or G3. Ply Sheet (Optional); One or more layers of Type Cl. Membrane; anWe One or more layers of "Rubernid Torch" (smooth or granule) or Rub rdo{d r h Plus" (granule), "Ruberoid Mop" (smooth or Mop Plus" (granule). LOOK FOR THE UL MARK ON ROOF COVERING MATERIALS (TEVT) Roofing Systems (TGFU) Continued 17 Cap Sheet: "GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped 1. Deck: C -15/32 Class Incline: ? -l; Insulation (Optional): One or mor: 'avers perlite. wood fiber, glas fiber, isocvanurate, urethane, perlite /tsczaattrate composite pr•Itt:• urethane composite, wood fiber /isocvanurate composite, phenolic ar thickness. Ply Sheet: Twu or more lavers o' Type GI "GAFGL.SS Pl■ •1' t "GAFGLAS Ply 6" Cap Sheet: Type G3 "CAFGLAS Mineral Swfaced Cap Shea•' h.. mopped. 2. Deck: C -13/3 Incline: 3 1 'Insulation (Optional): One or more lavers perlite, wood fiber. _la • fiber, isocvanurate, urethane, perlite!tsocvanurate composite. perlit• Methane composite, wood fiber; isoc . anurate rompos,te. phenolic an.. thickness. Base Sheet: Two or more layers of Type GI, G2 or G3. Membrane: One or more lavers of "Ruberoid Torch" (smooth or granule), "Rubcroid Torch Plus" (granule), "Ruberold Moe • t;ruott to granule) or "Ruberoid Mop Plus" (granule). Cap Sheet: "CAFGLAS Mineral Surfaced Cap Shirt ", ho: : :h.•;sp,d 1. Deck C -15/ 32 Class C Incline: 1/ Insulation (Optional): One or more I, yers perlite, wtcd ii!',-r. 81,1,5 fiber. isocvanurate, urethane, perlite; isocvanurate composite. pnhte/ urethane composite, wood fiberitsocvanurate composite, phenolic any thickness. - Ply Sheet: Three or more lavers of Tvpe G: "GAFC.iI.AS Ply 4' or "CAFGLAS Ph' 6". Surfacing: "Special Roofing Bitumen" 20 lbs!sq. COAL TAR FELT SYSTEMS WITH 11OT ROOFING COAL TAR 1. Deck: C•15/32 Class A Incline: 1 /2 Insulation (Optional): One or more layers pe rlite• h•e fiber, glass fiber, isoc }anurate, urethane, perlite; isotyanurate composite, perlite/ urethane composite, wood fiber!isocyantirate composite, phenolic, any thickness. Ply Sheet Three or more lavers of Tvjte G1 "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ", hot mopped with coat tar bitumen. Surfacing: Gravel. COMBINATION HOT AND COLD SYSTEMS Class A •• 1. Deck: NC Incline: Insulation (Optional): One or more layer . p rlite, h "oott fiber or glass fiber, 2 in. max. Ply Sheet Three or more lavers of Type G1 "GAFGLAS I'Iv 4" or "GAFGLAS Ply 6 ". Surfacing: Grundy Industries "al MB Alui r rn Rc,of Coating"- at' 1-1/2 gal /sq.• , _ _ - u : 2. L7ec1c: NC • Incline: 1 Insulation (Optional): One or more layers ; prlite, wood fiber, glass fiber, isocyanthrate, urethane, perlite /isocya:turs to composite, l•erht "/ urethane composite, wood fiber /isocyanurate composite, phenolic. any thickness. Ply Sheet Three or more layers of Type GI '"GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Surfacing: "Weather Coat Emulsion" at 3 gal /sal• • 3. Deck: NC Incline: 1/ Z Insulation: One or two layers "Isotherm R•', 4 in., hot mopped. Ply Sheet Any UL Classified gravel surfacers Class A asphalt glass fiber mat system. 4. Deck: NC Incline: 2 Insulation (Optional): Isocyanurate, perlite, isvc3•anurate /composite, wood fiber and glass fiber, any thickness, mecharmically fastened. Base Sheet One ply Type Cl or Q. mechans cally fastened or hot mopped. ply Sheet One or more plies Type GI or G2, ad! >' ered with hot roofing asphalt. S acing: •'GAF Premium Fibered Aluminum ..T°' Coating". 1.1 /2 ga sq or "CAF Weather Coat Emulsion ", 3 ga) /s ' 5. Dec NC Incllnr.1 • Ins'alation (Optional): Perlite, glass polyiso wool fiber, mechanically fastened, any thickness. RODUCT