725 NE 93 St (4)'s-
ME� ADE METROPOLITAN DADE COUNTY. FLORIDA
METRO-DADE FLAGLER BUILDING
PRODUCT CONTROL NOTICE OF ACCEPTANCE MIAMI, FLORIDA 33130.1563
(305) 375 -2901
FAX (305) 375 -2908
Stanley Door Systems
1225 E. Maple
Troy,
MI 48084
Your application for Product Approval of:
Series Sta - Tru - Steel Cladding Foam Filled Swing Wood Door (Deadbolt Lock)
under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and
Types of Construction, and completely desc lrit bed in the plans, specifications and calculations as submitted by:
Applicant, Stanley Door Systems along with Miami Testing Laboratory, Inc. test report No.
MTL 16201 dated: August 22, 1994 and test report No. MTL -16065 dated April 15, 1994
both signed and sealed by Ernest E. Mitchell, P.E.
has been recommended for acceptance by the Building Code Compliance office to be used in Dade
County, Florida under the specific conditions set-forth on pages 2 et. seq. and the Standard Conditions
on page 3.
This approval shall be valid for a period of three years. The Office of Code Compliance reserves
the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality
control testing. If this product or material fails to perform in the approved manner, the Code Compliance
Department may revoke, modify, or suspend the use of such product or material immediately. The Building
Code Compliance Department reserves the right to require retesting of this product or material should any
amendments to the South Florida Building Code be enacted affecting this product or material.
The expense of such testing will be incurred by the manufacturer.
Acceptance No.:94- 0928.03 (supersedes No.: 94- 0714.04)
BUILDING CODE COMPLIANCE DEPARTMENT
• SUITE 1603
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET
Expires:08/31 /98 r f.1 Di. .n., P.E.
' roduct Control Division
Supervisor
THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL
CONDITIONS
BUILDING CODE COMMITTEE
This application for Product Approval has been reviewed by the Metropolitan Dade County Building
Code Compliance Department and approved by the Building Code Committee to be used in Dade
County, Florida under the conditions set forth above.
Approved:11 /10/94 -1-
s anger,
Director
Building Code Compliance Dept.
Metropolitan Dade County
Stanley Door System
DESCRIPTION OF UNIT
MODEL DESIGNATION;
Series Sta -Tru; Steel Cladding with Flush
or Embossed Paneled; Foam Filled Inswing
or Outswing Entrance Door (Deadbolt Lock)
OVERALL SIZE:
37 3/8" wide by 81 1/2" high 6" deep
CONFIGURATION : X
No. & SIZE OF
-2-
ACCEPTANCE No.: 94- 0928.03
APPROVED
EXPIRES : August 31. 1998
NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS
NOV 1 0 1094
ASSIGNED ACCEPTANCE MARKINGS
Impact Test PA 201 -94
Cyclic Wind Pressure Test PA 203 -94
SFBC 3603.2 -76
Dade County Approval # 94- 0928.03
Expires: August 31, 1998
PANELS: One; 35 3/4" wide by 79" high 1 11/16" thick.
WEATHERSTRIPPING: Vinyl compression weatherstrip on each jamb head. An applied
dual vinyl durometer vinyl weatherstrip adapter under bottom of door panel consisting of a rigid
base with three flexible flaps; one 0.4" long, one 0.48" long and one 0.60" long. One neoprene
pad at bottom of hinge jamb, fabricated to fit frame. One 1 11/16" x 2" closed cell urethane
foam/polyethylene jacket pad at bottom of lock jamb OR single row of vinyl flap with magnetic
strip in frame head and the left (lock stile) frame jamb. Single row of vinyl flap in right (jamb
stile) frame jamb. An applied dual durometer vinyl weatherstrip adapter under bottom of door
panel consisting of a rigid base with a double flexible flap toward the interior edge and a flexible
bulb with a single flap at exterior edge. One neoprene pad at bottom of left frame jamb,
fabricated to fit frame. One 5/8" by 1 1/2" long closed cell foam pad at bottom of right frame
jamb.
OPERATORS & LOCATIONS: One metallic throw bolt lock at panel lock stile, 40 1/4"
from bottom, key operated on the exterior and turn knob at panel lock stile, 34 3/4" from bottom,
key operated on the exterior and thumb turn the interior. One slide bolt at the top and
bottom of panel lock stile mounted to door with three #7 x 1 1/2" screws and 3/8" spacer on
swing out doors with two #8 x 2" screws in slide bolt strikers. Three standard 4 x 4 butt hinges
located at 8 1/8 ", 39 1/8 ", and 70 1/8" from bottom of door of hinge installed on the frame jamb
with eight #9 x 5/8" long flat head screws and four #9 2 1/4" long flat head ews (Two in top
hinge, one in center and one in the bottom). Dead r or equiv Tent.
Gil Diamond, P.E.
Product Control Division
Supervisor
Stanley Door System ACCEPTANCE No.: 94- 0928.03
APPROVED
NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS
WEEPHOLES: None
MUNTINS: None
FRAME CONSTRUCTION: Header and jambs are 4 9/16" Ponderosa Pine or equivalent.
METAL SKIN THICKNESS: .018" steel skin.
THRESHOLD: Extruded aluminum 1 1/4" height x 6" width with thermal break.
REINFORCEMENT : None
NOV 1 01994
EXPIRES : August 31. 1998
ADDITIONAL DESCRIPTION: Equal leg type frame. Unit tested using an aluminum
threshold with thermal break in the frame sill. Strike plate secured to frame using three No. 10
by 2 1 /2 "OR two #8 x 2" installation screws. The product markings are located on the hinge side
of the door at mid height OR at midspan of frame sill.
INSTALLATION OF JAMB AND STRIKE PLATES: Hinge side of jamb is installed with
four #8 x 3" long screws at 6 1/8 ", 37 1/8 ", 68 1/8 ", and 76 1/8" from bottom. Lock side of jamb
is installed with four #8 x 3" long screws at 2 1/4", 28 1/8", 53 1/4", and 79 1/4" from bottom.
Slide latch strike plates installed with two #8 x 2" screws. Throw bolt strike plate installed with
two #8 x 2" screws. Door latch strike plate installed with two #8 x 2" screws OR strike plate
secured to frame using two No. 10 x 2 1/2" installation screws.
SLAB CONSTRUCTION: Entry door 1- 11/16" thick. .018 steel skins. 1.219 width of wood
on top and bottom rails and on latch stile. 2 -3/4" x 12.00" lockblock. .938 thick hinge stile.
Skins fastened to stiles and rails with neoprene base contact adhesive. Slab painted with grey or
white primer (thermoset waterborne acrylic). Core is polyurethane fill.
-2a-
Gil Diamond, P.
Supervisor
•
Product Control Division
TEST
TEST LOAD
DESIGN LOAD
UNIFORM STATIC AIR PRESSURE TEST
SFBC PA 202 -94 POSITIVE
+80.0 PSF
+53.33 PSF
UNIFORM STATIC AIR PRESSURE TEST
SFBC PA 202 -94 NEGATIVE
-105.0 PSF
-70.0 PSF
WATER RESISTANCE (PSF)
ASTM E547/E331 '
6.50 PSF
+43.3 PSF
AIR INFILTRATION @ 1.57 PSF
ASTM E283 ( <0.37 CFM/FT
0.09 CFM /FT'
--- -----
FORCED -ENTRY RESISTANCE (FER)
SFBC 3603.2 (b)
MTL -16201
LARGE MISSILE IMPACT TEST
SFBC PA 201 -94
SATISFACTORY
MTL -1 6201
CYCLIC WIND PRESSURE TEST
SFBC PA 203 -94 POSITIVE
+69.0 PSF
+53.08 PSF
CYCLIC WIND PRESSURE TEST
SFBC PA 203 -94 NEGATIVE
-91.0 PSF
-70.00 PSF
Design Pressure Rating (Positive)
+43.3 PSF
Design Pressure Rating (Negative)
-70.0 PSF
INSTALLATION:
Stanley Door System ACCEPTANCE No.: 94- 0928.03
APPROVED
EXPIRES : August 31. 1998
NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS
NOV 1 0 1994
SCREWS AND METHOD OF ATTACHMENT:
SILL : None
HEAD : None
JAMBS : #10 x 2 1/2" FH Wood screws at a max. of 6" from corners and 24" apart.
OR # 8 x 2" FH Wood screws at a max. of 6" from corners and 24" apart.
(4) #9 x 2 1/4" FH Wood screws at hinges.
Note: Please see note #1 I. Page 3
A copy of this approval as well as manufacturer's installation instructions shall be provid s to the
permit applicant by the manufacturer or his distributors and slyatt',e 4 ilable for ins • do - at
the jobsite at all time.
-2b-
Gil Diamond, P.E.
Supervisor
Product Control Division
• Stanley Door System ACCEPTANCE No.: 94- 0928.03
TYPICAL ELEVATION:
+•3/+• TYP.
2+•
TYP.
24'
TYP.
2+'
TYP.
+ -3/+' TYP.
MUGU 01 EmBOSSEO
r
This approval applies to single unit applications only, as shown above.
-2c-
APPROVED . NOV 1 0 1994
EXPIRES : August 31. 1998
NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS
USE . B X 3' SCRENS
ion MOUNTING won JMO
(I -I /+• SECTION) TO 2'
NOMINAL SUB -BUCK (09) RE0'0.
(SUPPLIED BY OTMER).
Units with dimensions smaller than those shown above shall qualify under this approval. Deviations for
higher design pressures by downsizing the unit are accepted only thru comparative analysis approved by
this Department.
Sub -bucks shall be of pressure treated material at least 2" nominal thickness, and secured in at least 6
points on each leg with 3" or equivalent fasteners.
Fasteners must have their own Notice of Acceptance and must be made of stainless steel or have
adequate protection against corrosion, per DIN 50018. Aluminum contacting metals not considered
compatible shall be properly protected.
This revision supersedes Notice of Acceptance No. 94- 0714.04 date . j, 1994.
it Diamond, P.E.
Supervisor
Product Control Division
NOTICE OF ACCEPTANCE: STANDARD CONDITIONS FOR GLAZED PRODUCTS
1. For multiple window installations, approved mullion drawings and calculations must be
filed with Product Control.
2. This Acceptance will qualify smaller units of the same design and as the unit tested.
3. All units must be labeled. giving the manufacturer's name. Dade Countv Product Control
Approval Number. approved elevation and date of expiration.
4. Extension of Acceptance may be considered after a new application has been filed and the
supporting data, for test reports less than four (4) years old, has been re- evaluated.
5. Any revision or change in materials, use or manufacture of the product shall automatically
be cause for termination, unless prior approval is granted for revision or cha e.
6. Any unsatisfactory performance of this product or a change in Code provisions shall be
grounds for re- evaluation.
7 This Acceptance shall not be used as an endorsement of any product sales or advert sing
purposes.
8. Aluminum windows and sliding doors have been tested in accordance with zNSUAANLA
101 -83 or for wood window unit by ANSI/NWWDA I.S. 2 -87 and sliding doors
ANSI/NWWDA I.S. 3 -8 and swing doors ANSI/NWWDA I.S. 8 -83.
9. Swinging doors shall be tested for positive and negative wind pressures as per Chapter 23
of the South Florida Building code.
10. Hardware for all windows and doors shall conform to Security and Forces Entry
Prevention, Chapter 36 of the South Florida Building Code.
11. The spacing of fasteners shall be as tested or 24" whichever is less.
R_ The first fastener shall be located a maNimum of 6" from each corner and mullion or stile.
Minimum penetration of fastener shall be as tested or 3/4" whichever is higher. No wood
or plastic shields or pins shall be used.
Unless otherwise noted in the test report, minimum size of screws shall be No. S for first
and second floor installations and No. 10 for all other floors above the first ad second
floors.
Revised 5 -20 -92 -3-
1
31 Diamond, P.E'
roduct Control Division
• Supervisor
CCM IMP
An buWttllon Ind Pan rag tn NmuWDns
1 Mea o n 0 IM MO l w 0O U
M rw ••• rt • ate lee w w SCOW IMO n ar
— w • We wile w (lama WNW a slaw To swum a IC
a1.1111 mom aatrrat Wow low ago I. Noma
P A 1 N T1 N GI
• wog germ we, aow tun a Amy appal
taaww:aerlwwwlr mom rlra
mowwwwft
• WOW 4.101•1 a bats NINA ape Se Om
w Mwwaaaoaarw glow or or MEW
• Ulis Iron Hoye. Atm arr.nsawn t
Iwwaawow • wow .r10 — w
w w Iarse ewaawglesrra
•noaw•N•• airurn Wasp Nam-
Ow VW wow raw — as
ISM DD NOT PAINT DIUMOWSWIR
C A 0 T 1 O N
• De at we mom swarm Mom et
W ow wwps Woo slows.
• a•w NOR iwwwawta and as awator
rw wNE aanhewwwmiamm __
naallaaw• wrwww• wpm a•••
• a at rasark aawaa oar war a www
a llr w wear ow MO ow wows
atatwwww wows lilt 8 _wwa•nl
ameamwwwwwwiwapummum,
a»ttlwaot.
MOOS • *Om /rarer ataa wr
bawls= awgper Mire r w rl
Oar, allldww 8111, •.sco••• how
awl Intl need, 41 Om a1
Ynhrerew MN real enwrap.
STANLEY DOOR ATOMS
1" w
nano in Owaq rAwlr
Aw11ma. Ifs >la� T altL a 4
Slily Door Spans
Uri/ boy, Midis=
11 •■� � tlrrtlWO/IYo Two w.
lIQ O+►AM .tws.ldrr�r•�
rrlalalLlr awaaNl OS ammo Mims •wrawww
i
ItNUw
P T1A DOOR IS GLAZED
Vi MY R w M s
ND um= VANJ&
stN� l
Stanley Door Systems
Troy, Michigan g
Saetbefe.t - angina 20 Net. Rand wood Frame st
Sae Almelo. Tore Fa era in wood. Neel and and taaam , Ili
NER QA 409 walk. Mot be end with fee rand door t"
SWRI Rehm= Na. 9203$ end banterer .
1 AO 1 LEM
L86S0
'04 OItIMO
STA -TRU THRESHOLD
•SWING -1N•
STA -TRU
WEATHERSTRIP:
HEADER.
MAT'L.: MAGNETIC
W /VINYL JACKET.
JAMB. HEADER
4-9/16'
NAT'L: POCEROSA PINE OR
EOJIVALEM.
CAULK. LATEX.
EXTERIOR JOINTS AND
UNDER THRESHOLD.
WEATHERSTRIP. HINGE
. REF.
SEAL - H1NGE
NAT'L: EPOM FOAM W/
SELF ADHESIVE BACKING
BRICKMOLD (OPTIONAL)
HEADER: 1 - 1/4' X 2.0'
NAT'L: PONDEROSA PINE
OR EQUIVALENT.
SECTION B - B
CAULK.LATEX.
EXTERIOR JOINTS ANO
UNDER THRESHOLD.
SEAL-LATCH
MAT'L.: EPOM FOAM
STA -TRU THRESHOLD
OPTIONAL 'SWING-OUT'
STA -TRU TH
'SWING-1N'
WEATHERSTRIP.
LATCH. REF.
WEATHERSTRIP. H1
REF.
STA -TRU THRESHOLD
OrT 1104AL • SWING -OUT•
B OTTOM SWEEP
NAT'L: DUAL
0I TER VINYL.
THRESHOLD
NAT'L: ALUMINUM
W/ THERMAL BEAK.
SLAB -
STA•TRL
1-11/lE
.021 5?
1.219 1.
PERINET
STILE!
-3/4'
SKINS F
AND RA)
BASE CC
CORE 1
9..A6 53
2/BX6/1
2/816/F
2/10X6.
3/OX6/1
SOt
se
(SJ
.
SEE
UcT
DEAO8OLT
100 SERI
OR
1T
'A• SERI
1/2' LAT
PW4T ST
SCREWS.
SEAL -HINGE
NAT'L: EPDM FON
W /SELF ADHESIVE
B ACKING
CAULK. LATEX. JOINTS
N DE R 0
BOTTOM
MO
x
AN
MD
(2
NAT'L.: D.ML QUO
VINYL. CAULKED M AND STAPLUD.W /t4)
STAPLES.
DO NOT SCALE THIS DRS
REVISIONS
RELEASED lEmt4w1"
GEl F�CFT1
HINGE 4' X 4'
.060' STEEL W/
CIA. STEEL PIN.
(3 REO'D.
AT SCREWS:
TO
(737:9 �1
FLA TO JAMB:
Z le9 s X 5 /8' AND
e9 X 2 -1/4 STEEL
T HEAD SCREWS.
ACTUAL PRODUCT MEETS OR EXCEEDS
PRODUCT NOTICE OF ACCEPTANCE
THROUGH THE USE OF MATERIALS
AT OR GREATER THAN THOSE TESTED.
I I
DUCT
APPROVAL
ND.
UNIFORM STATIC AIR
PRE'SSL E- POSITIVE
9FBC PA 202-94
UNIFORM STATIC AIR
PRESS- NEBITIVE
9FBC PA 202-94
WATER RESISTANCE
ASTM E547/E331
TUT
+ 80.0
▪ 105.0
8.50
TUT
LOAD
PIS
•53.3
-70.0
•43.3
DUNN
LOAD
ECM
DADE COUNTY
STANLEY DOOR SYSTEMS
OZVIWOV OP M RA .KV WORM=
TRW. MICMMU M,
PRODUCT ENGINEER PEER I NG
PANT MOMS STA -TRU:
PM ENTRY DOOR W/O -BOLT t SURFACE BOLTS
1IICCPM6® *WY t INSTALLATION
IMITIUCT1O!S OF PM VIII.
MAT11111011
AS NOTED
anAMm r+ OA bye 0A sw+u.a •o.
7 -7-
S A
QA 05987
P. LATCH
rag
EPDM FOAM
SRI
—CALK. LATEX.
EXTERIOR JOINTS AND
UNDER THRESHOLD.
MOLD
' DOOR:
O(.
;IONS.
OF W000 ON
1.640 THICK.
RAIL).
00' L OWILLE (.
-ED TO STILES
TH NEOPRENE
ADHESIVE.
!URETHANE FILLED
29.75' X 79.00'
31.75' X 79.00'
33.75' X 79.00'
35.75' X 79.00'. 0.
0 8 RE0'
E air/ APPROVAL
IA. MOUNTING INSTR-
?�AGE
RAGE
3/4' BAOCSET
ROW OR EOIJIVALENT.
PLATES W/88 X 2 -1/2°
E BOLT
MUIR%
TOM RAIL.
TRIKER WITH
X 2 -1/2'
' RED
O ED
x
5.500
34.730
JAMB. LATCH
(SEE HEADER)
WEATHERSTRIP: LATCH
2.250
26.000
211.000
STA -TRU
WEATHERSTRIP:
LATCH.
NAT'L.: MAGNETIC
W/V INYL JACKET.
SEAL -LATCH
2/6 • 35.500
2/8 • 37.500
2/10 • 39.500
3/0 • 41.500
• .
2/6 • 31.500
2/8 • 33.500
2/10 • 35.500
3/0 • 37.500
SECTION A - A
FRAME I.D. LABEL
ON HEADER.
B
/
r \
15/16'
TYP. B
WEAR
WEATHTHERR
STRIP:
HINGE.
MAT'L.: VINYL
COMPRESSION.
I OOIOLD
JAMB. HINGE
(SEE HEADER)
WEATHERSTRIP: HINGE
SEAL -MIME
—2.000
A T .000
DOOR
DOE LABEL
///
DOOR.
2.000T
2.000
NOTE : ALL EXTERIOR JOINTS TO BE CALKED.