Loading...
725 NE 93 St (4)'s- ME� ADE METROPOLITAN DADE COUNTY. FLORIDA METRO-DADE FLAGLER BUILDING PRODUCT CONTROL NOTICE OF ACCEPTANCE MIAMI, FLORIDA 33130.1563 (305) 375 -2901 FAX (305) 375 -2908 Stanley Door Systems 1225 E. Maple Troy, MI 48084 Your application for Product Approval of: Series Sta - Tru - Steel Cladding Foam Filled Swing Wood Door (Deadbolt Lock) under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely desc lrit bed in the plans, specifications and calculations as submitted by: Applicant, Stanley Door Systems along with Miami Testing Laboratory, Inc. test report No. MTL 16201 dated: August 22, 1994 and test report No. MTL -16065 dated April 15, 1994 both signed and sealed by Ernest E. Mitchell, P.E. has been recommended for acceptance by the Building Code Compliance office to be used in Dade County, Florida under the specific conditions set-forth on pages 2 et. seq. and the Standard Conditions on page 3. This approval shall be valid for a period of three years. The Office of Code Compliance reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Code Compliance Department may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compliance Department reserves the right to require retesting of this product or material should any amendments to the South Florida Building Code be enacted affecting this product or material. The expense of such testing will be incurred by the manufacturer. Acceptance No.:94- 0928.03 (supersedes No.: 94- 0714.04) BUILDING CODE COMPLIANCE DEPARTMENT • SUITE 1603 METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET Expires:08/31 /98 r f.1 Di. .n., P.E. ' roduct Control Division Supervisor THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. Approved:11 /10/94 -1- s anger, Director Building Code Compliance Dept. Metropolitan Dade County Stanley Door System DESCRIPTION OF UNIT MODEL DESIGNATION; Series Sta -Tru; Steel Cladding with Flush or Embossed Paneled; Foam Filled Inswing or Outswing Entrance Door (Deadbolt Lock) OVERALL SIZE: 37 3/8" wide by 81 1/2" high 6" deep CONFIGURATION : X No. & SIZE OF -2- ACCEPTANCE No.: 94- 0928.03 APPROVED EXPIRES : August 31. 1998 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS NOV 1 0 1094 ASSIGNED ACCEPTANCE MARKINGS Impact Test PA 201 -94 Cyclic Wind Pressure Test PA 203 -94 SFBC 3603.2 -76 Dade County Approval # 94- 0928.03 Expires: August 31, 1998 PANELS: One; 35 3/4" wide by 79" high 1 11/16" thick. WEATHERSTRIPPING: Vinyl compression weatherstrip on each jamb head. An applied dual vinyl durometer vinyl weatherstrip adapter under bottom of door panel consisting of a rigid base with three flexible flaps; one 0.4" long, one 0.48" long and one 0.60" long. One neoprene pad at bottom of hinge jamb, fabricated to fit frame. One 1 11/16" x 2" closed cell urethane foam/polyethylene jacket pad at bottom of lock jamb OR single row of vinyl flap with magnetic strip in frame head and the left (lock stile) frame jamb. Single row of vinyl flap in right (jamb stile) frame jamb. An applied dual durometer vinyl weatherstrip adapter under bottom of door panel consisting of a rigid base with a double flexible flap toward the interior edge and a flexible bulb with a single flap at exterior edge. One neoprene pad at bottom of left frame jamb, fabricated to fit frame. One 5/8" by 1 1/2" long closed cell foam pad at bottom of right frame jamb. OPERATORS & LOCATIONS: One metallic throw bolt lock at panel lock stile, 40 1/4" from bottom, key operated on the exterior and turn knob at panel lock stile, 34 3/4" from bottom, key operated on the exterior and thumb turn the interior. One slide bolt at the top and bottom of panel lock stile mounted to door with three #7 x 1 1/2" screws and 3/8" spacer on swing out doors with two #8 x 2" screws in slide bolt strikers. Three standard 4 x 4 butt hinges located at 8 1/8 ", 39 1/8 ", and 70 1/8" from bottom of door of hinge installed on the frame jamb with eight #9 x 5/8" long flat head screws and four #9 2 1/4" long flat head ews (Two in top hinge, one in center and one in the bottom). Dead r or equiv Tent. Gil Diamond, P.E. Product Control Division Supervisor Stanley Door System ACCEPTANCE No.: 94- 0928.03 APPROVED NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS WEEPHOLES: None MUNTINS: None FRAME CONSTRUCTION: Header and jambs are 4 9/16" Ponderosa Pine or equivalent. METAL SKIN THICKNESS: .018" steel skin. THRESHOLD: Extruded aluminum 1 1/4" height x 6" width with thermal break. REINFORCEMENT : None NOV 1 01994 EXPIRES : August 31. 1998 ADDITIONAL DESCRIPTION: Equal leg type frame. Unit tested using an aluminum threshold with thermal break in the frame sill. Strike plate secured to frame using three No. 10 by 2 1 /2 "OR two #8 x 2" installation screws. The product markings are located on the hinge side of the door at mid height OR at midspan of frame sill. INSTALLATION OF JAMB AND STRIKE PLATES: Hinge side of jamb is installed with four #8 x 3" long screws at 6 1/8 ", 37 1/8 ", 68 1/8 ", and 76 1/8" from bottom. Lock side of jamb is installed with four #8 x 3" long screws at 2 1/4", 28 1/8", 53 1/4", and 79 1/4" from bottom. Slide latch strike plates installed with two #8 x 2" screws. Throw bolt strike plate installed with two #8 x 2" screws. Door latch strike plate installed with two #8 x 2" screws OR strike plate secured to frame using two No. 10 x 2 1/2" installation screws. SLAB CONSTRUCTION: Entry door 1- 11/16" thick. .018 steel skins. 1.219 width of wood on top and bottom rails and on latch stile. 2 -3/4" x 12.00" lockblock. .938 thick hinge stile. Skins fastened to stiles and rails with neoprene base contact adhesive. Slab painted with grey or white primer (thermoset waterborne acrylic). Core is polyurethane fill. -2a- Gil Diamond, P. Supervisor • Product Control Division TEST TEST LOAD DESIGN LOAD UNIFORM STATIC AIR PRESSURE TEST SFBC PA 202 -94 POSITIVE +80.0 PSF +53.33 PSF UNIFORM STATIC AIR PRESSURE TEST SFBC PA 202 -94 NEGATIVE -105.0 PSF -70.0 PSF WATER RESISTANCE (PSF) ASTM E547/E331 ' 6.50 PSF +43.3 PSF AIR INFILTRATION @ 1.57 PSF ASTM E283 ( <0.37 CFM/FT 0.09 CFM /FT' --- ----- FORCED -ENTRY RESISTANCE (FER) SFBC 3603.2 (b) MTL -16201 LARGE MISSILE IMPACT TEST SFBC PA 201 -94 SATISFACTORY MTL -1 6201 CYCLIC WIND PRESSURE TEST SFBC PA 203 -94 POSITIVE +69.0 PSF +53.08 PSF CYCLIC WIND PRESSURE TEST SFBC PA 203 -94 NEGATIVE -91.0 PSF -70.00 PSF Design Pressure Rating (Positive) +43.3 PSF Design Pressure Rating (Negative) -70.0 PSF INSTALLATION: Stanley Door System ACCEPTANCE No.: 94- 0928.03 APPROVED EXPIRES : August 31. 1998 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS NOV 1 0 1994 SCREWS AND METHOD OF ATTACHMENT: SILL : None HEAD : None JAMBS : #10 x 2 1/2" FH Wood screws at a max. of 6" from corners and 24" apart. OR # 8 x 2" FH Wood screws at a max. of 6" from corners and 24" apart. (4) #9 x 2 1/4" FH Wood screws at hinges. Note: Please see note #1 I. Page 3 A copy of this approval as well as manufacturer's installation instructions shall be provid s to the permit applicant by the manufacturer or his distributors and slyatt',e 4 ilable for ins • do - at the jobsite at all time. -2b- Gil Diamond, P.E. Supervisor Product Control Division • Stanley Door System ACCEPTANCE No.: 94- 0928.03 TYPICAL ELEVATION: +•3/+• TYP. 2+• TYP. 24' TYP. 2+' TYP. + -3/+' TYP. MUGU 01 EmBOSSEO r This approval applies to single unit applications only, as shown above. -2c- APPROVED . NOV 1 0 1994 EXPIRES : August 31. 1998 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS USE . B X 3' SCRENS ion MOUNTING won JMO (I -I /+• SECTION) TO 2' NOMINAL SUB -BUCK (09) RE0'0. (SUPPLIED BY OTMER). Units with dimensions smaller than those shown above shall qualify under this approval. Deviations for higher design pressures by downsizing the unit are accepted only thru comparative analysis approved by this Department. Sub -bucks shall be of pressure treated material at least 2" nominal thickness, and secured in at least 6 points on each leg with 3" or equivalent fasteners. Fasteners must have their own Notice of Acceptance and must be made of stainless steel or have adequate protection against corrosion, per DIN 50018. Aluminum contacting metals not considered compatible shall be properly protected. This revision supersedes Notice of Acceptance No. 94- 0714.04 date . j, 1994. it Diamond, P.E. Supervisor Product Control Division NOTICE OF ACCEPTANCE: STANDARD CONDITIONS FOR GLAZED PRODUCTS 1. For multiple window installations, approved mullion drawings and calculations must be filed with Product Control. 2. This Acceptance will qualify smaller units of the same design and as the unit tested. 3. All units must be labeled. giving the manufacturer's name. Dade Countv Product Control Approval Number. approved elevation and date of expiration. 4. Extension of Acceptance may be considered after a new application has been filed and the supporting data, for test reports less than four (4) years old, has been re- evaluated. 5. Any revision or change in materials, use or manufacture of the product shall automatically be cause for termination, unless prior approval is granted for revision or cha e. 6. Any unsatisfactory performance of this product or a change in Code provisions shall be grounds for re- evaluation. 7 This Acceptance shall not be used as an endorsement of any product sales or advert sing purposes. 8. Aluminum windows and sliding doors have been tested in accordance with zNSUAANLA 101 -83 or for wood window unit by ANSI/NWWDA I.S. 2 -87 and sliding doors ANSI/NWWDA I.S. 3 -8 and swing doors ANSI/NWWDA I.S. 8 -83. 9. Swinging doors shall be tested for positive and negative wind pressures as per Chapter 23 of the South Florida Building code. 10. Hardware for all windows and doors shall conform to Security and Forces Entry Prevention, Chapter 36 of the South Florida Building Code. 11. The spacing of fasteners shall be as tested or 24" whichever is less. R_ The first fastener shall be located a maNimum of 6" from each corner and mullion or stile. Minimum penetration of fastener shall be as tested or 3/4" whichever is higher. No wood or plastic shields or pins shall be used. Unless otherwise noted in the test report, minimum size of screws shall be No. S for first and second floor installations and No. 10 for all other floors above the first ad second floors. Revised 5 -20 -92 -3- 1 31 Diamond, P.E' roduct Control Division • Supervisor CCM IMP An buWttllon Ind Pan rag tn NmuWDns 1 Mea o n 0 IM MO l w 0O U M rw ••• rt • ate lee w w SCOW IMO n ar — w • We wile w (lama WNW a slaw To swum a IC a1.1111 mom aatrrat Wow low ago I. Noma P A 1 N T1 N GI • wog germ we, aow tun a Amy appal taaww:aerlwwwlr mom rlra mowwwwft • WOW 4.101•1 a bats NINA ape Se Om w Mwwaaaoaarw glow or or MEW • Ulis Iron Hoye. Atm arr.nsawn t Iwwaawow • wow .r10 — w w w Iarse ewaawglesrra •noaw•N•• airurn Wasp Nam- Ow VW wow raw — as ISM DD NOT PAINT DIUMOWSWIR C A 0 T 1 O N • De at we mom swarm Mom et W ow wwps Woo slows. • a•w NOR iwwwawta and as awator rw wNE aanhewwwmiamm __ naallaaw• wrwww• wpm a••• • a at rasark aawaa oar war a www a llr w wear ow MO ow wows atatwwww wows lilt 8 _wwa•nl ameamwwwwwwiwapummum, a»ttlwaot. MOOS • *Om /rarer ataa wr bawls= awgper Mire r w rl Oar, allldww 8111, •.sco••• how awl Intl need, 41 Om a1 Ynhrerew MN real enwrap. STANLEY DOOR ATOMS 1" w nano in Owaq rAwlr Aw11ma. Ifs >la� T altL a 4 Slily Door Spans Uri/ boy, Midis= 11 •■� � tlrrtlWO/IYo Two w. lIQ O+►AM .tws.ldrr�r•� rrlalalLlr awaaNl OS ammo Mims •wrawww i ItNUw P T1A DOOR IS GLAZED Vi MY R w M s ND um= VANJ& stN� l Stanley Door Systems Troy, Michigan g Saetbefe.t - angina 20 Net. Rand wood Frame st Sae Almelo. Tore Fa era in wood. Neel and and taaam , Ili NER QA 409 walk. Mot be end with fee rand door t" SWRI Rehm= Na. 9203$ end banterer . 1 AO 1 LEM L86S0 '04 OItIMO STA -TRU THRESHOLD •SWING -1N• STA -TRU WEATHERSTRIP: HEADER. MAT'L.: MAGNETIC W /VINYL JACKET. JAMB. HEADER 4-9/16' NAT'L: POCEROSA PINE OR EOJIVALEM. CAULK. LATEX. EXTERIOR JOINTS AND UNDER THRESHOLD. WEATHERSTRIP. HINGE . REF. SEAL - H1NGE NAT'L: EPOM FOAM W/ SELF ADHESIVE BACKING BRICKMOLD (OPTIONAL) HEADER: 1 - 1/4' X 2.0' NAT'L: PONDEROSA PINE OR EQUIVALENT. SECTION B - B CAULK.LATEX. EXTERIOR JOINTS ANO UNDER THRESHOLD. SEAL-LATCH MAT'L.: EPOM FOAM STA -TRU THRESHOLD OPTIONAL 'SWING-OUT' STA -TRU TH 'SWING-1N' WEATHERSTRIP. LATCH. REF. WEATHERSTRIP. H1 REF. STA -TRU THRESHOLD OrT 1104AL • SWING -OUT• B OTTOM SWEEP NAT'L: DUAL 0I TER VINYL. THRESHOLD NAT'L: ALUMINUM W/ THERMAL BEAK. SLAB - STA•TRL 1-11/lE .021 5? 1.219 1. PERINET STILE! -3/4' SKINS F AND RA) BASE CC CORE 1 9..A6 53 2/BX6/1 2/816/F 2/10X6. 3/OX6/1 SOt se (SJ . SEE UcT DEAO8OLT 100 SERI OR 1T 'A• SERI 1/2' LAT PW4T ST SCREWS. SEAL -HINGE NAT'L: EPDM FON W /SELF ADHESIVE B ACKING CAULK. LATEX. JOINTS N DE R 0 BOTTOM MO x AN MD (2 NAT'L.: D.ML QUO VINYL. CAULKED M AND STAPLUD.W /t4) STAPLES. DO NOT SCALE THIS DRS REVISIONS RELEASED lEmt4w1" GEl F�CFT1 HINGE 4' X 4' .060' STEEL W/ CIA. STEEL PIN. (3 REO'D. AT SCREWS: TO (737:9 �1 FLA TO JAMB: Z le9 s X 5 /8' AND e9 X 2 -1/4 STEEL T HEAD SCREWS. ACTUAL PRODUCT MEETS OR EXCEEDS PRODUCT NOTICE OF ACCEPTANCE THROUGH THE USE OF MATERIALS AT OR GREATER THAN THOSE TESTED. I I DUCT APPROVAL ND. UNIFORM STATIC AIR PRE'SSL E- POSITIVE 9FBC PA 202-94 UNIFORM STATIC AIR PRESS- NEBITIVE 9FBC PA 202-94 WATER RESISTANCE ASTM E547/E331 TUT + 80.0 ▪ 105.0 8.50 TUT LOAD PIS •53.3 -70.0 •43.3 DUNN LOAD ECM DADE COUNTY STANLEY DOOR SYSTEMS OZVIWOV OP M RA .KV WORM= TRW. MICMMU M, PRODUCT ENGINEER PEER I NG PANT MOMS STA -TRU: PM ENTRY DOOR W/O -BOLT t SURFACE BOLTS 1IICCPM6® *WY t INSTALLATION IMITIUCT1O!S OF PM VIII. MAT11111011 AS NOTED anAMm r+ OA bye 0A sw+u.a •o. 7 -7- S A QA 05987 P. LATCH rag EPDM FOAM SRI —CALK. LATEX. EXTERIOR JOINTS AND UNDER THRESHOLD. MOLD ' DOOR: O(. ;IONS. OF W000 ON 1.640 THICK. RAIL). 00' L OWILLE (. -ED TO STILES TH NEOPRENE ADHESIVE. !URETHANE FILLED 29.75' X 79.00' 31.75' X 79.00' 33.75' X 79.00' 35.75' X 79.00'. 0. 0 8 RE0' E air/ APPROVAL IA. MOUNTING INSTR- ?�AGE RAGE 3/4' BAOCSET ROW OR EOIJIVALENT. PLATES W/88 X 2 -1/2° E BOLT MUIR% TOM RAIL. TRIKER WITH X 2 -1/2' ' RED O ED x 5.500 34.730 JAMB. LATCH (SEE HEADER) WEATHERSTRIP: LATCH 2.250 26.000 211.000 STA -TRU WEATHERSTRIP: LATCH. NAT'L.: MAGNETIC W/V INYL JACKET. SEAL -LATCH 2/6 • 35.500 2/8 • 37.500 2/10 • 39.500 3/0 • 41.500 • . 2/6 • 31.500 2/8 • 33.500 2/10 • 35.500 3/0 • 37.500 SECTION A - A FRAME I.D. LABEL ON HEADER. B / r \ 15/16' TYP. B WEAR WEATHTHERR STRIP: HINGE. MAT'L.: VINYL COMPRESSION. I OOIOLD JAMB. HINGE (SEE HEADER) WEATHERSTRIP: HINGE SEAL -MIME —2.000 A T .000 DOOR DOE LABEL /// DOOR. 2.000T 2.000 NOTE : ALL EXTERIOR JOINTS TO BE CALKED. G Tn./RAKES ON FRACTIONS * 1/64.0ECIMAI..S 1.015.ANGLES *1'.UNLESS OTHERWISE SPECIFIED.