700 NE 93 St (7)Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build-
ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
_...D._ Date.. .. .__ ,19 ?
Owner's Name and Address ........ iQ.wA 4.4 ..4 11 .'L!!k No...��..QQ.._ . Street .f
....'r� :.�'
Registered Architect and /or Engineer ..... ..JO•y•. ••AAi o70.yeede
Name and address of licensed contractor j".. 44 OslrAP
Location and legal description of lot to be built on:
Lot ` r 1 Block 4 3 Subdivision .09e4 .A */* 'r , fit.jire! ..�
...
Street and Number where work is to be done 7.0.a..._. °._ ..
State work to be done and purpose of building (by floors)...__. ita _t/_.....
permit, as are licensed by Miami Shores Village. �.
Remarks.__ • ( r red)
STATE OF FLORIDA,
COUNTY OF DADE. ss.
Disapproved �JDate..
( Signed) (//, ,
BUILDING INSPECTION DEPARTMENT
APPLICATION FOR BUILDING PERMIT
Building'Inspcctor
MIAMI SHORES VILLAGE
Member
Member
Member
Disapproved
and for no other purpose.
New Building* Remodeling Addition if Repairs No. of Stories / —
To be constructed of Kind of foundation Covering L 4
thaw .(' .............._..._
I z ` t � —
Estimated Total cost of improvements $ $ Amount of Permit S,.
Zone cubage required Plan Cubage
Distance to next nearest building Size of Building Lot
Maximum live load to be borne by each floor
I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may
be sent to
The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer
of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement,
and has complied with the wovisions thereof, and will require similar compliance from all -rtra rs or sub - contractors employed by him
in the work to be performed under this permit; and will post or cause to be posted for ins ctiosron the site of t k s ublic notice
or notices as are required by the Act. The undersigned agrees to employ only-such su • , tr itors, on . o performed under this
NINC BOARD DATE
Notary Public, State of Florida
My Commission Expires
Chairman
Member
Member _....-- -.._._ ...._
Council Approved Date
NOTE: A charge of $1.00 will be made for making corrections
the Planning Board.
A re inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice
materials and /or workmanship.
or changes to this application after approval
Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap-
peared
and who, being by me first duly sworn, upon oath deposes and says that he is the.
of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts
therein by him stated are l true.
Permit No 9 _...._.._.. Date d, Sworn to and Subscribed before me.
..__ _ . _ -1.
to me well known,
Date
has been obtained Iran
for inspection or faulty
Date ' I ?8 Job Address
Legal Description Historically Designated: Yes
Owner/Lessee / Tenant (Y til�rx L, y t 1ea . Oft
Owner's Address " - 7 b 0 N F_ 93 rd S�--
Contracting Co. r7X flCw Q
Qualifier
State #
Square Ft
FEES: PERMIT
o.TQ,'v o 0 Cato- e4icocAn
ffLq
Architect/Engineer Address
Bonding Company Address N
Pr Mortgagor Address
Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL
WORK DESCRIPTION 76stie air T /A✓C /— ��F 7S y�A 5 ha ci t , ?! i n 134“,/y
1 ( (6(74 4-ktel .nd Kau' Estimated Cost (value) 7, rp (1 • w
345.55
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.)
Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I
certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNER'S e. iAVIT:
la
Signature of owner and/or Condo President
silAceib, X
Notary as to Owner and/or Condo President Date
My Commission..'pp , SAND : • `�' BA
:1,4 c , i- CCO373
. E j Cf itZFj J,AiZ f2. 2Q I
..t, ; wa�o� ,r+
� 6 4 0F 0 AR/uoiC BONDING CO., INC.
w 2
RADON
APPROVED:
Zoning Building
Mechanical
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE
770
I /Z 1 /Se
Tax Folio f /' 3 2b( — 638 — 60 / b
No i /
Master Permit # L/ Z13
Phone 75 7- /0Y/
Address 6 13 � 5 POLL
ss# Phone
Municipal # Competency # / j b(„ Ins. Co.
the foregoing information is accurate and that all work will be done in compliance with all applicable
uthorize the above -named contractor> • o the work stat - • /
of Contractor or Owner - Builder
Notary as to Contractor or Owner- Builder
My Commission Expires:, .
•
.: CC ISSiON : :3
U
}! EXPIRES MAR O CO.t
,�� AILAM►C BONDED BONDING
C.C.F. L NOTARY BOND /GO
Electrical
AVING FENCE SIGN
TOTAL DUE
d 4/4 &mites
//2 923
D e
ibL)98
Date
Plumbing Engineering
NOTICE OF COMMENCEMENT
A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF .FIRST INSPECTION
PERMIT NO. TAX FOLIO NO. 11 - 3 2,o( b 3g - o g)
STATE OF FLORIDA:
COUNTY OF DADE:
THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with
Chapter. 713, Florida Statutes, the following information is provided in this Notice of Commencement.
1. Legal description of property and street address: mtryui, S-f.A+ CO- °f Q�tx¢K.tn
2. Description of improvement:
3. Owner(s) name and address: ( Yxt� .1t t..A4 CD —t t
Interest in property: 814r-"4,A
Name and address of fee simple titleholder:
4. Contractor's name and address: Olcke_A i.tA
5. Surety:(Payment bond required by owner from contractor, if any)
Name and address:
Amount of bond $
fr
A l
7. Persons within the State of Florida designated by Owner upon whortrnotices or other documents may be served as provided
6. Lender's name and address:
by Section 713.13(1)(a)7., Florida Statutes,
Name and address:
8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in
Section 713.13(1)(b), Florida Statutes.
Name and address:
Print Owners Name
Sworn to and subscribed bef
tiouxurt £h)e I N
'? 16 NE 9i St /YIL6:✓M Y
1112.)1,-q Cpcw.e.S re166
N
c
98R048314 1998 FEB 02 14:41
E3 y
iyyto J ,Zt.A.0? C .Qi 1t /.f i , i--
l ntg�1 - +tiC�[p�
STATE OF FLORIDA, COUNTY OF DADE
I HEREBY CERTIFY fl +af this is a truo cony of flso
orfginolfilod is this offico on day of
W TNESS p my h,nd and O' fiicio1 Scol.
I ARVEt 1\1 ERK, ircui
9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a
a..
4' C COMMISSION • CC623733
EXPIRES MAR 12, 2001
Notary Public �.Is i ' ' . `1 , i t :.
Print Notary's Name
My Commission Expires:
THROUGH
o co. tic.
SANOrA � 1-I,4r
,19`18 .
Prepared by: CA..riCiti
aunt
Address: t4(QC) 4 f' -S
2 .P Pi R 3302-1
®.C.
12301-52 2193
Contractor's Name: O/ /)O(L4' ODO
ROOF CATEGORY
(Low Slope Application) ❑ (Nail -On Tile) ❑ (Mortar- Adhesive Set Tile)
❑ (Asphalt/Fiberglass Shingles) ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other)
ROOF TYPE
❑ New Roof E"Re roofing ❑ Recovering ❑ Repair ❑ Maintenance
Flat Roof Area (ft Sloped Roof Area (ft Total (ft S Master Permit No.
Exposure category (per AS E 7 -88): C Building Classification category (per A CE 7 -88 table 1):
Ft.
F
ass shripe
64 s NA pI
Deck type: W l . . l / 1 "'ARV.
Appendix "E"
UNIFORM ROOFING PERMIT APPLICATION
PROCESS No.
ROOF HEIGHT AND SYSTEM DETAILS
ATTACHMENT
4
Fastener Type:
1
��
SPACING
rlto II s00 il N i$
Field: 4 Z Perimeter: 4 10 Corner: to 4 - 4
2
3
P S P o W �' o
S 0
DDITAIL 1 & 2 S
F 2
f1 ifsa<,8° =3G
Peytme,16 5pk11u9
123 01-78 9/98 5 / e i t _ -
—L td ' (O, (,G 51-
Job Address:
(Draw details as needed) o
4 Ot
777 NE 9 / ..4
r
r
r
r
ROOF PLAN
>f)(i4'SfAi,Nq
Page -1 3t x / ?�
S ��
— 1'z *(*604 & If
V
Strip & Removal
S
OWNER PROJECT NUMBER
Fee Check Number
1
r�• / I
/P - f
Wrecking Ball
Wet Method' \
Other
*Dry Method
Explode
Bum Down
V
Strip & Removal
S
v-h ;
Glove B5%,,_)
Buli \ I .
Wrecking Ball
Wet Method' \
*Dry Method
Explode
Bum Down
IV.
s • , 6 t
I. Facility Name
Address Z 1 N 1 j 1 t 1 r r -,
City I ,,
Site 21 ifs
Building Size '3 t t) (S Feet) # of Floors
II. Fee Receipt Will Be Sent to Address in Block Below: (Print or Type)
III. Facility Owner Phone (
Address
City State Zip
Fold Line
Contractor's Name r ''r, C I
Address: r �'
City: i' , a rn /
Phone
•
f
Aft r
State /7 _ Zip:
Florida License No.:
V. Dem �tion ❑ Removal l`1 Demolition with no ACM ❑
k i)'/Ob r
Removal: Start Date 1 Finish Date
Demolition: Start Date
Finish Date
VI. REMOVAUDEMOLmON PROCEDURES TO BE USED
MUST OBTAIN PRIOR DEP APPROVAL BEFORE USING A DRY METHOD!
VII. Waste Disposal Site Name ! � , /rat a t I i /Y
Address ! , t . �, , 0, S ,�' -*5 .3 � LA V\ 1.
VIII. Fee Calculation & Type of RACM in enovations or ACM in Demolitions
RACM? " ` L L
(circle Yeser'N \
Square Feet Surfacing Material Yes No
Linear Feet Pipe Yes No
Square Feet Cementitious Material Yes No
Square Feet Resilient Flooring Yes No
I' ware Feet Asphalt Roofing Yes No
gr/0 'foal RAC �(squar) *slaw feet)
$ Enclosed (See Fee Schedule) ❑ Check if Demolition Only
ANN
A.= ia. Vi. I mo . . 1 1 , oeM. +:..,r rt ..-- 4, -,• v9��X+JrYL ac. ,.9AYenr. t±►ie4r�`+�A' +sY:�, *�
SOUTHLAND BUSINESS FORMS (305) 888-2906
ORIGINAL TO:
Florida Department of Environmental Protection
State Asbestos Coordinator
2600 Blair Stone Road
Tallahassee, Florida 32399 -2400
I!I(.I
Type of Notice:
t
NOTICE OF ASBESTOS REMOVAL PROJECT
I Original ❑ Revised ❑ Cancelled
v �
State
I Zip
Surveyed by . t
Age in Years 2 5 Prior Use
Emergency ❑
Annual ❑
SEND YELLOW COPY TO:
Metro -Dade DERM
Air Facilities Section
33 S.W. 2nd Avenue, Suite 9 -223
Miami, Florida 33130 -1540
Class
` State!?
IX Asbestos Waste Transporter
{
lllan9e'�.����t
/ / � f:•
Phone ( )
X. Procedures for Unexpected RACM
, , i r /-
� r
I certify that the above information is50
(Signature of Owner /Operator)
(Date)
DEP USE ONLY
Postmark
NESHAP ... Yes ... No ...
Deposit No.
Fee Received $
APIS #
Date Received
Reviewed By: JUG kt (o itiez Nte: Z//2.1g S
it? 1
PLAN REVIEW SEA 'J'IOl!
AIR RE 'r 5 7
This is to certify that OK rr r-;, vdd notification(s)
•vat' , .� :zs vr: Omitted in
COI ij Et • 1%it:; „r: .. •� : ,� * "7%P4tionS
Signature
� � ,
r
� .
it
OWNER PROJECT NUMBER
Fee Check Number
`;,- y
0.1. Y '' i. V
i - -) 1
Y7 ' r
r r .,?At .
',/,,)( ,tt'e-
Fi
Other
ORIGINAL TO:
Florida Department of Environmental Protection
State Asbestos Coordinator
2600 Blair Stone Road
Tallahassee, Florida 32399 -2400
I. Facility Name ` ' ( ' `-.1 )r 'f
Address r \
OF A RE 'C REM V7A:1: ?: ' C::: C''
Type of Notice: Original ❑ Revised ❑ Cancelled
i s
i yr . -'
City ''`F'' 1:'.", vn t Q-. i''''.1 -
Site 71 ' .-' G' i 57
Building Size 511 ( 0 ( Square Feet) # of Floors 1
II. Fee Receipt Will Be Sent to Address in Block Below: (Print or Type)
III. Facility Owner
Address
Cit State Zip
Fold Line
IV.
Contractor's Name
Address: f ,/ r 9 r
City: / d i :.''} re) 6 g / re
Phone (• , S ) i' </, /
V. Demo ition ❑ Removal d Demolition with no ACM ❑
f
Removal: Start Date
VI. REMOVAL/DEMOUTION PROCEDURES TO BE USED
SOUTHLAND BUSINESS FORMS (305) 888 - 2906
* MUST OBTAIN PRIOR DEP APPROVAL BEFORE USING A DRY METHOD!
VII. Waste Disposal Site Name tr y / b ,. ®1/
Address IV r � T . t`$ Jt
State
Finish Date f I Demolition: Start Date
Strip & Removal
Wet Method
Glove Bag
*Dry Method
Bulldozer
Explode
Wrecking Ball
Bum Down
VIII. Fee Calculation & Type of RACM in Renovations or ACM in Demolitions
RACM?
(circle Yes or No)
Square Feet Surfacing Material Yes No
Linear Feet Pipe Yes No
Square Feet Cementitious Material Yes No
Square Feet Resilient Flooring Yes No
. e' '`°' Square Feet Asphalt Roofing Yes No
le",t)4 IWRACM((square timer feet)
$ ( 4) > Enclosed (See Fee Schedule) 0 Check if Demolition Only
METRODADE
Zip
Surveyed •
Age in Years i
State 1 /
Florida License No.: 4
Emergency El
City
Phone
SEND YELLOW COPY TO:
Metro -Dade DERM
Air Facilities Section
33 S.W. 2nd Avenue, Suite 9 -223
Miami, Florida 33130 -1540
Zip:
Annual El
Prior Use
Finish Date
Class
State`"_
IX. Asbestos Waste Transporter
Name f l �ys�' Ac v
Phone (;.d. c. )
X. Procedures for Unexpected RACM
I certify that the a ve information iscorrect:
/ /
(Signature of Owner /Operator)
d (Date)
DEP USE ONLY
Postmark
NESHAP ... Yes ... No ...
Deposit No.
Fee Received $
APIS #
Date Received
Th. is Ii') Cnti tt tYle
CDI3
Reviewed lizt:
mar
Signature :
PLAN 11EVIINV SE .7TION
"t^! I' ired notjlicationM
!Ten submikted in
regLLitions
61 1410ett-C.: .11.11%*110ErearyaNcErr***P4'
GEOT.ECHNICAL
ENVIRONMENTAL
HYDROGEOLOGY
ASBESTOS
Miami, January 27, 1998
Mr. Jim Obenour
OBENOUR ROOFING
9325 Park Drive, Suite F
Miami Shores, FL 33138
Re: Apartment
770 N.E. 91st Street
Miami Shores, FL
Dear Mr. Obenour:
mite fir" c cciaM 94 •\
���� :1rSriii;!
DYNATECH ENGINEERING CORP.
TESTING LABORATORIES
DRILLING SERVICES
INSPECTION SERVICES
ROOFING
Pursuant to your request; DYNATECH ENGINEERING CORP., conducted an Asbestos Roof
Survey on January 26, 1998 at the above referenced project. The purpose of our inspection was
to secure bulk samples for analysis to determine the presence of Asbestos Containing Materials
in the proposed roof renovation area.
The scope of our inspection covered the following areas:
A- Entire Roof Top at the above referenced project.
Based on our laboratory analysis; it was evident that asbestos fibers were found in the following
secured bulk samples:
1- Perimeter Plastic Cement/Bull:
Perimeter Plastic Cement/Bull was found with 2 -5% chrysotile asbestos fibers.
Based on our visual inspection, physical site assessment and potential for damage, it was evident
that the roof material is considered Category I - Non friable material is considered Category I -
Non friable material. It is our opinion that this materials need not be removed prior to
demolition because generally these materials do not release significant amounts of asbestos fibers
when damaged. Yet, in the event of future repair and replacement of the roof material, all work
shall be conducted by a Florida Licensed Roofing Contractors with on site Roofing Asbestos
Supervision as provided in Section 469.012 of F.A.C. and in compliance with NESHAPS and
OSHA regulations. We further recommend a competent person be on site for Air Monitoring
during removal of A.C.M.
750 West 84 Street, Hialeah, FL 33014 -3618 • Phone (305) 828 -7499 • Fax (305) 828 -9598
Page No. 2
770 N.E. 91st Street
This inspection report is the results of a diligent search of the facility for asbestos containing
building materials (A.C.B.M.). All analyzed samples were readily available to our surveyor.
We do not claim to have identified all of the asbestos containing building material present in
the facility. If in the course of a renovation or demolition activity, suspect materials become
exposed, all activities should immediately cease and the suspect material brought to our attention
for evaluation and recommendation.
This report is designed to aid the building Owner, Architect, Construction Manager, General
Contractors, and Potential Asbestos Abatement Contractors in locating ASBESTOS
CONTAINED MATERIALS. Under no circumstances is this report to be utilized as a proposal
or a project specification document.
When implementing the response actions, parties responsible for final selection should remember
that actions shall be sufficient to protect HUMAN HEALTH AND THE ENVIRONMENT, but
may also be the least burdensome method. Nothing in these recommendations should be
construed as PROHIBITING or discouraging removal.
It has bee a pleasure serving you at this phase of your project and look forward to do so in the
near future.
Sincerely yours,
Wissam ani, P.E.
DYNATECH ENGINEERING CORP.
Florida Reg. No. 39584
Asbestos Consultant Number EA 0000045
WN /sr
e
o
r� Location
Description
Approximate
Amount
—
F
NF
Condition/ • .
Potential
for
Damage
,Analysisyt
•
I I II N.W. Perimeter I
Plastic Cement/Bull
1 150 Sq. Ft.
I G/L 112-5% Chry.
I G/L II N.A.D.
1 2 II West Area
Built Up Roof Tar /Gravel Membrane
( 3450 Sq.Ft.
X
(3
(East Area
Built Up Roof Tar /Gravel Membrane
3450 Sq.Ft.
❑ X
❑ X
LILI
G/L
l N.A.D.
1 4
(S.E. Perimeter
I
Plastic Cement/Bull
150 Sq. Ft.
I
(G /L I(2
II
I
-5% Chry.
I
I
I II
I
I
I
LI❑
EIIII[1I
On
SD
I
I
I I
I
II
II 1
II
I II I
I
I I I
I
Date
Client
Project :
Surveyor No.:
Sample Type:
January 27, 1998
OBENOUR ROOFING
770 N.E. 91st Street, Miami Beach, FL
7ME090203003DS By:SC
Bulk Samples Analy P.L.M. /D.S.
NF = Non Friable
N.A.D. = No Asbestos Detected
CHRY = Chrysotile
AMS = Amosite
CRD = Crocidolite
CONDITION
G = Good
D= Damaged
S= Significantly Damaged
DYNATECH ENGINEERING CORP.
ASBESTOS SAMPLING REPORT
750 W. 84th Street, Hialeah, FL
POTENTIAL FOR DAMAGE
L=Low
M= Medium
H =High
A nal yzed by: S imon ralacios
DYNATECH ENG NEERING CORP.
NIOSH 582 Cert. 7ME090203003DS
c
1
I)YNA'I'ECII ENGINEERING CORP.
CIicnI: OBENOIIR ROOFING
I'rojcci: 770 N.E. 91st Street, Miami Shores, FL
i
Scales NTS
i ,.,., 1 -26 -98
Drawn Urs SC
n..l..Ji WN
A
METRO -
PRODUCT CONTROL NOTICE OF ACCEPTANCE
The expense of such testing will be incurred by the manufacturer.
Acceptance No.: 97- 0804.21 Revises No.: 95- 1003.03
Expires: 11/04/00
Approved: 11/04/97
Internet mail address: postmaster @buildingcodeonline.com
•
.::.: %
• •■•
METROPOLITAN DADE COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
BUILDING CODE COMPLIANCE OFFICE
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130 -1563
(305) 375-2901
FAX (305) 375 -2908
aul Rodriguez
Product Control Supervisor
PRODUCT CONTROL DIVISION
(305) 375-2902
FAX (305) 372 -6339
CA Materials Corporation
1361 Alps Road
Wayne, NJ 07470
Your application for Product Approval of:
GAF Conventional Built Roof Systems for Wood Decks
under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of
Construction, and completely described in the plans, specifications and calculations as submitted by:
Dynatech Engineering, Inc., Factory Mutual Research Corporation, and Underwriters Laboratories, Inc.
has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida
under the specific conditions set forth on pages 2 -40 and the standard conditions on page 4 I.
This approval shall not be valid after the expiration date stated below. The Building Code Compliance Office
reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality
control testing. If this product or material fails to perform in the approved manner, the Building Code Compliance
Office may revoke, modify, or suspend the use of such product or material immediately. The Building Code
Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance
Office that this product or material fails to meet the requirements of the Building Code Compliance Office that this
product or material fails to meet the requirements of the South Florida Building Code.
THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL
CONDITIONS
BUILDING CODE COMMITTEE
This application for Product Approval has been reviewed by the Metropolitan Dade Cqunty Building Code
Compliance Office and approved by the Building Code Committee to be used in Dade County, Florid under the
conditions set forth above.
Charles Danger, P.E.
Director
Building Code Compliance Dept.
Metropolitan Dade County
Homepage: http : / /www.buildingcodeonline.com
• Product Control No: 97- 0804.21
Applicant:
GAF Materials Corporation
1361 Alps Road
Wayne, NJ 07470
PRODUCT CONTROL NOTICE OF ACCEPTANCE
ROOFING SYSTEM APPROVAL
Category: Membrane Roofing System
Sub - Category: Built -up Roofing
Type: Conventional
Sub -Type: Fiberglass
System Description
GAF Materials Corporation, a manufacturer of commercial roofing products for more than 100 years,
produces a wide range of roof products for built -up and modified bitumen roofing systems. In addition,
GAF offers two ply modified systems to meet the demands for multi -ply SBS modified specifications.
GAF provides warranted systems over various insulated and non - insulated substrates, copies of which
can be obtained from GAF and can be found in the "GAFGLAS Built -Up Roofing Application and
Specifications" manual published annually.
GAF roof system assemblies have been extensively tested at Factory Mutual Research Corporation and
Underwriters Laboratories and have been tested in compliance with all requirements of the South Florida
Building Code. Specific classifications for assemblies are listed in the current U.L. Roofing Material
Directory and the current Factory Mutual Approval Guide.
GAF Materials Corporation products are distributed through a wide network of roofing wholesale
distributors throughout the South Florida area.
For more information on specific roof system constructions, contact the Technical Service Office, located
in Wayne, New Jersey, at 1- 800 - ROOF -411.
Contact:
William J. Woodring
Director of Technical Services
(973) 628- 4134
Page 2 of 41
Product Control No.: 97 0804.21
Approval Date: November 4, 1997
Expiration Date: November 4, 2000
ran Zuloaga,
Roofing Product Control Examiner
• Product Control No: 97- 0804.21
Insulation Types:
Material
Wood
Material
Wood
Basalt Wool
Perl ite
Polyisocyanurate
Composite Board
Wood Fiberboard
High Density Wood Fiberboard
Rockwool
Maximum Design Pressure
Design Pressure
-75psf
Maximum Fire Classification
Classification
Class 'A'
Note: Fire classifications and maximum design pressures do not reference all assemblies over all deck
types. Review system listings for design pressures and the Underwriters Laboratories Roofing
Materials Directory for Fire Classifications.
Page 3 of 41
Roofing Product Control Examiner
Product
GAF Asphalt
Concrete Primer
GAF Mineral Shield®
Granules
GAF WeatherCoat®
Emulsion
GAF Premium
Fibered Aluminum
Roof Coating
GAF Jetblak All
Weather Plastic
Cement
RUBEROID®
Modified Bitumen
Flashing Cement
Jetblack Premium
Flashing Cement
GAFGLAS® #75
GAFGLAS #80
Ultima Base Sheet
GAFGLAS Ply 6®
GAFGLAS Flex
piyTM 6
GAFGLAS Ply 4®
TRADE NAMES OF PRODUCTS MANUFACTURED OR
LABELED BY APPLICANT
Test
Dimensions Specification
Product
Description
5, 55 gallons ASTM D 41 Asphalt concrete primer used to promote
adhesion of asphalt in built -up roofing.
60 lb. bags ASTM D 1863 Granules for surfacing of exposed
asphalt, cold process cement or
emulsion. GAF Mineral Shield®
Granules shall be used for flashing
applications only.
5 gallons ASTM 1227 Surface coating for smooth surfaced
roofs.
I, 5 gallons ASTM D 2824 Fibered aluminum coating.
1, 5 gallons
5 gallons
5 gallons
3 sq. roll
75 lb. roll
2 Sq. Roll
70 lbs./roll
5 sq. roll
45 lb. roll
5 sq. roll
45 lb. roll
5 sq. roll
ASTM D 3019
ASTM D 3409
Product Control No: 97 0804.21
Refined asphalt blended with a mineral
stabilizer and fibers. Permits adhesion
to wet and dry surfaces.
ASTM D 4586 Fiber reinforced, polymer modified
Flashing cement
ASTM D 4586 Asphalt flashing Cement
ASTM D 4601 Asphalt impregnated and coated glass
mat base sheet.
ASTM D4601 Asphalt impregnated and coated,
fiberglass base sheet
ASTM D 2178 Type VI asphalt impregnated glass felt
with asphalt coating.
ASTM D 2178 Type VI asphalt impregnated glass felt
with asphalt coating.
ASTM D 2178 Type IV asphalt impregnated glass felt
with asphalt opting_
Page 4 of 4
0o mg Product Comm
Product
RUBEROID®
TORCH PLUS
RUBEROID®
TORCH FR
RUBEROID® 30
RUBEROID® 30 FR
RUBEROID
ULTRACLAD® SBS
Vent Stacks (metal
and plastic)
GAF Aluminum
Emulsion
RUBEROID® 109. Roll
ULTRACLAD® SBS 101 lbs.
GAF Built -Up
Roofing Asphalt
Test
Dimensions Specification
3 /a sq. roll
93 lbs.
' /4 sq. roll
90 lbs.
1 sq. roll
92 lbs.
1 sq. roll
92 lbs.
5 gallons
GAF Aluminum Roof 5 gallons
Paint
100 lb. cartons,
bulk
RUBEROID MOD 60 lb. kegs
Asphalt
ASTM D 5147
ASTM D 5147
ASTM D 5147
!sq. roll ASTM D 5147
101 lbs.
ASTM D 5147 Heavy duty, polyester reinforced, coated
with fire retardant asphalt modified
bitumen membrane, granule surface.
PA 100(A)
ASTM D 1929
ASTM D 635
None
ASTM D 5147
ASTM D2824,
Type I
Page 8 of 41
Product Control No: 97- 0804.21
Product
Description
Heavy duty, polyester reinforced,
asphalt modified bitumen membrane,
granule surface
Non woven fiberglass mat coated with
polymer modified asphalt and surfaced
with mineral granules.
Non woven fiberglass mat coated with
fire retardant polymer modified asphalt
and surfaced with mineral granules.
Woven fiberglass mat coated with
Polymer modified asphalt and surfaced
with aluminum, copper or stainless steel
foil.
One way valve vent used to relieve
built -up pressure within the roof system.
GAF Vent Stacks are available in metal
or plastic.
Mineral colloidal bituminous emulsion
with reflective aluminum flakes
Woven fiberglass mat coated with
Polymer modified asphalt surfaced with
aluminum, copper or stainless steel foil.
Non- fibered. aluminum pigmented,
asphalt roof coating 7
ASTM D312, Interply mopping and surfacing asphalt
Types 1, 11, 111 and
IV
SEBS modified asphalt
Roofing Product Control Examiner
Test Product
Product Dimensions Specification Description
Dek fast Fasteners
#14
Dekfast Fasteners
#12
Perlite Insulation various
Polyethylene 4 mil min.
Red Rosin various
Roofing Nails
Minimum #
12
PA 114
Corrosion resistant annular
ring shank nails
Page 12 of 41
Product Control No: 97- 0804.21
Manufacturer
Dekfast Lock Plate 3" x 3 1/4" PA 114 Polypropylene locking Construction
plate. Fasteners Inc.
(with current PCA)
PA 114 Insulation fasteners for Construction
concrete decks Fasteners Inc.
(with current PCA)
PA 114 Insulation fastener for steel Construction
and wood decks. Fasteners Inc.
(with current PCA)
ISO 95+ Composite PA 110 Polyisocyanurate / perlite Firestone
ridged insulation (with current PCA)
Asphalt ASTM D 312 Type III or IV Hot asphlat generic
bitumin adhesive
Asphalt Primer ASTM D 41 Asphalt Primer generic
EPS various PA 110 Extruded polystyrene generic
insulation
High Density Wood various PA 110 Wood fiber insulation board generic
Fiberboard
Pelite /Urethane various PA 110 Perlite / urethane composite generic
Composite board insulation
PA 110 Perlite insulation board generic
Vapor barrier / Air barrier generic
kosin paper for barrier generic
layer on wood decks
generic
ga,
Roofing Product Control Examiner
Tin Caps
Product
MB aluminum roof
coating
Dens -Deck
#12 Roofgrip
#14 Roofgrip
Gripdek Fastener
Hexcel Fastener
Hextra
Standard Plastic
Plate
ISO 95+
E'N RG'Y -2
I SORoc
Test
Dimensions Specification
Min. 32 ga. x
I s /
various
3" round
various
various
various
Olympic Standard 3" round
Product
Description
Corrosion resistant circular
discs.
PA 121 Aluminum roof coating
PA 110 Gypsum insulation board.
PA 114 Insulation fastener for steel
or wood decks
PA 114 Insulation fastener steel,
wood or concrete decks
PA 114
PA 114
PA 114
PA 114
PA 110
PA 110
PA 110
Insulation fastener
Insulation fastener
Insulation fastener and
metal or plastic plate
Polyolefin plastic plate
Polyisocyanurate foam
insulation
Polyisocyanurate foam
insulation
Polyisocyanurate foam /
tockwool composite
insulation
PA 114 3" round galvalume
AZ55 steel plate
Page 13 of 41
Product Control No: 97- 0804.21
Manufacturer
generic
Grundy Industries
(with current PCA)
Georgia Pacific
(with current PCA)
ITW Buildex
(with current PCA)
ITW Buildex
(with current PCA)
ITW Buildex
(with current PCA)
ITW Buildex
(with current PCA)
1TW Buildex
(with current PCA)
ITW Buildex
(with current PCA)
Firestone
(with current PCA)
NRG Barriers, Inc.
(with current PCA)
NRG Barriers, Inc.
(with current PCA)
Olympic
Manufacturing
Group, Inc.
(with current PCA)
Roofing Product Control Examiner
Test
Name
Report
Date
Agency /Identifier
Factory Mutual Research
Corporation
Current Insulation
Attachment
Requirements
FMRC 1996
01.01.96
Factory Mutual Research
Corporation
Wind Uplift
FMRC 4470 - PA 114
J.I. OT4A I .AM
08.26.92
Factory Mutual Research
Corporation
Wind Uplift
FMRC 4470 - PA 114
J.I. 1V8A4.AM
06.28.93
Factory Mutual Research
Corporation
Wind Uplift
FMRC 4470 - PA 114
J.I. 1R1A6.AM
11.15.91
Factory Mutual Research
Corporation
Wind Uplift
FMRC 4470 - PA 114
J.I. 0T2Q4.AM
10.17.91
Factory Mutual Research
Corporation
Wind Uplift
FMRC 4470 - PA 114
J.I. 0Q6A6.AM
07.16.91
Factory Mutual Research
Corporation
Wind Uplift
FMRC 4470 - PA 114
J.I. 3X3A2.AM
08.02.94
Factory Mutual Research
Corporation
Wind Uplift
FMRC 4470 - PA 114
J.I. 0Y9Q5.AM
07.29.94
Factory Mutual Research
Corp.
Wind Uplift, FMRC
4470 - PA 114
J.I. 1B9A8.AM
Underwriters
Laboratories, Inc.
Fire Resistance
Classification
UL 790 - PA 114
R1306, 87NK11819
01.01.93
Dynatech Engineering
Corporation
Wind Uplift
PA 114
, #3600.02.95 -1
02.02.95
Dynatech Engineering
Corporation
Wind Uplift
PA 114
#4482.02.95 -1
02.02.95
TEST REPORTS
Product Control No: 97- 0804.21
Page 17 of 41
ga,
Roofing Product Control Examiner
• Deck Type 1:
Deck Description:
System Type A(2): Base sheet mechanically fastened.
All General and System Limitations shall apply.
Base Sheet:
Ply Sheet:
Cap Sheet:
Surfacing:
Maximum Design
Pressure:
Maximum Fire
Classification:
Maximum Slope:
Specification No.:
Wood, Non - insulated New Construction or Reroof
19 / 32 " or greater plywood or wood plank decks
Product Control No: 97- 0804.21
GAFGLAS® #75, GAFGLAS #80 Ultima Base Sheet, GAFGLAS® PLY 4 ®,
GAFGLAS® PLY 6 ®, GAFGLAS FlexPly, GAFGLAS® STRATAVENT®
Nailable, RUBEROID Modified Base Sheet or RUBEROID® 20 applied to the
deck with approved annular ring shank nails and minimum 1 ' / tin caps at a
fastener spacing of 9" o.c. at the lap, 12" o.c. in two rows staggered along the
center line of the sheet in the field.
Two or three plies of GAFGLAS® PLY 4 ®, GAFGLAS FlexPly 6 or
GAFGLAS® PLY 6® ply sheet adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20 -40 lbs. /sq..
(Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20 -40
lbs. /sq..
(Required if no cap sheet is used) Install one of the following:
1.GAF WEATHER COAT® Emulsion with an application rate of 3 gal. /sq.; or
GAF Premium Fibered Aluminum Roof Coating with an application rate of 1.5
gal. /sq..
2. Asphalt flood coat at an application rate of 60 lbs. /sq. ± 20 %; plus gravel or
slag with an application rate of 400 lbs. /sq. & 300 lbs. /sq., respectively.
-45 psf. (See General Limitation #7)
'A'. See General Limitation #2.
6 ":12 "; See General Limitation #3.
N- B -3 -G, N- B -3 -C, N- B -3 -M, N- B-4 -G, N- B- 4 -G /P6, N- B -4 -M, N7B- 4 -M /P6, N- B-4 -C,
N- B- 4 -C/P6, N- B -S -C, N- B- S -C/PC, N- B -5 -G, N- B- 5 -G /P6, N- B -5 -M, N- B- 5 -M/P6
Page 21 of 41
ga,
Roofing Product Control Examiner
Wood Deck System Limitations:
Product Control No: 97- 0804.21
I . Fastener spacing for anchor sheet attachment is based on a Minimum Characteristic Force (F')
of 95 lbf or greater as tested in compliance with Merto -Dade County Protocol PA 105. If F' as
tested is below 95 lbf, a professional engineer may submit a revised fastener spacing utilizing
the withdrawal resistance value taken from Merto -Dade County Protocol PA 105 and
calculations in compliance with Metro -Dade Roofing Application Stanadrd PA 117.
2 All standard insulation panel sizes are acceptable for mechanical attachment. When panels are
applied in hot asphalt, maximum panel size shall be 4' x 4'.
a. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') of
275 lbf. as tested in compliance with Merto -Dade County Protocol PA 105 & Roofing
Application Standard PA 117. If the fastener value, as field tested, are below 275 lbf. insulation
attachment shall not be acceptable.
3 A slip sheet is required with Ply 4® Flex Ply' 6 and Ply 68 when used as a mechanically fastened
base or anchor sheet.
4. % Type X gypsum board is acceptable to be installed directly over the wood deck..
Page 37 of 41
u oaga,
Roofing Product Control Examiner
GENERAL LIMITATIONS
Page 38 of 41
Product Control No: 97- 0804.21
I All asphalt shall comply with ASTM D 312 type III or type IV requirements, and
approved by applicant.
2 Fire ratings are determined by a combination of slope, deck type and assembly. Refer to
current Underwriters Roofing Materials Directory or other fire testing data listed in the
testing file. Fire ratings shall be in strict compliance with Sections 3401.5 and 3401.6 of
the South Florida Building Code.
3 Maximum slope range shall vary for each system; consult current Underwriters
Laboratories Roofing Materials Directory and manufacturer's specifications for
compliance with design criteria for each project.
4 An overlay and/or recovery board insulation panel is required on all applications over
closed cell foam insulations when the base sheet is fully mopped. If no recovery board is
used, install one layer of GAFGLASS STRATAVENT Perforated, laid dry.A base sheet
may be applied using spot mopping with approved asphalt, 12" diameter circles :24" o.c.;
or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of
the sheet allowing a continuous area of ventilation. Encircling of the strips is not
acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation.
Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note:
Spot attached systems shall be limited to a maximum design pressure of -45 psf. Where
STRATAVENT Perforated is used over approved isocyanurate foam insulation, the
maximum design pressure is limited to — 60psf.
5 All work shall be performed by a contractor licensed to do roofing work in Metro - Dade
County. Contractor shall be familiar with the details and specifications published by the
manufacturer, and the requirements of the SFBC.
6 The submission of system specifications and details shall accompany the Section II
Building Code Permit. This information is available in the publications listed in the
'System Description' of this Product Control Approval. The submission of these
documents, as well as the proper application and installation of all materials shall be the
sole responsibility of the contractor.
ran Zuloaga,
Roofing Product Control Examiner
Product Control No: 97- 0804.21
7 Perimeter and corner areas shall comply with the enhanced uplift pressure of these areas,
as calculated in compliance with Chapter 23 of the South Florida Building Code. Fastener
densities shall be increase for both insulation and base sheet as needed calculated in compliance
with Metro -Dade County Roofing Application Standard PA 117. (When this limitation is
specifically referred within this NOA, General Limitation #20 will not be applicable.)
8 All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination
designs shall conform with Metro -Dade County Roofing Application Standard PA 111
and the wind load requirements of Chapter 23 of the South Florida Building Code.
9 Flashings shall be installed according to the manufacturers standard details, and may be
applied in cold application adhesive, approved asphalt or may be applied in conjunction
with an approved torch applied modified bitumen membrane. Specific details, approved
by the manufacturer, shall be submitted with the Section II Permit Application. All details
shall comply with the provision of the South Florida Building Code.
I0 Fastener spacing for base sheet attachment is based on a Minimum Characteristic Force
(F') value as tested in compliance with Metro -Dade County Protocol PA 105. If the fastener
values as tested are below those listed in the System Limitations, a professional engineer may
submit a revised fastener spacing utilizing the withdrawal resistance value taken from a Metro -
Dade County Protocol PA 105 test report and calculations that comply with the wind load
requirements of Chapter 23 of the South Florida Building Code and Roofing Application Standard
PA 117.
1 I Fastener spacing for insulation attachment is based on a Minimum Characteristic Force
(F') value of 275 lbf., as tested in compliance with PA 105. If the fastener value, as field tested,
are below 275 lbf. insulation attachment shall not be acceptable.
1 Asphalt moppings shall be with applied with approved asphalt and shall be in compliance
with equiviscous temperature (EVT) methods of asphalt determination. Asphalt containers or
bulk tickets shall indicate an EVT, finished blowing temperature (FBT) and flash point. Asphalt
types and temperature ranges shall be in compliance with Subsection 3403.4(a)(3) of the South
Florida Building Code.
13 Insulation may be installed in multiple layers. The first layer shall be attached in
compliance with Product Control Approval guidelines. All other layers shall be adhered
in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40
lbs. /sq., or mechanically attached using the fastening pattern of the top layer. Refer to
manufacturer's literature and/or the NRCA Roofing and Waterproofing Manual for correct
application procedures of insulation panels in approved asphalt or adhesive, which shall
comply with provision of Roofing Application Standard PA 117.
Page 39 of 4 I
Roofing Product Control
4 -
•
Product Control No: 97- 0804.21
14 All standard panel sizes are acceptable for mechanical attachment. When applied in
approved asphalt, panel size shall be 4' x 4' maximum.
15 In re- covery/re- roofing applications, prior to the application, all existing roof surfaces used as a
bonding substrate shall be tested in compliance with Metro -Dade County Protocol PA 124 for
uplift resistance. Test pressures shall be calculated in compliance with the wind load
requirements of Chapter 23 of the South Florida Building Code to the design pressure of the roof.
16 In re- roofing applications, moisture content in an existing roof must be in compliance with
Section 3401.10(m), (n) of the South Florida Building Code.
17 Roll good materials shall be stored on end and on a clean, flat and dry surface.
18 If required, any Factory Mutual Approved vapor barrier in conjunction with proprietary or
approved adhesives may be used prior to the application of the insulation layer.
19 Consult current Underwriters Laboratories Directory for the appropriate coating for each
roofing assembly to obtain the required fire rating. The assembly shall be installed in
strict compliance with sections 3401.5 and 3401.6 of the South Florida Building Code for
maximum fire classification.
20 The maximum designed pressure limitation listed shall be applicable to all roof pressure
zones (i.e. field, perimeters, corners). No rational analysis, nor extrapolation shall be
permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended
corners, and corners). (When this limitation is specifically referred within this NOA,
General Limitation #7 will not be applicable.)
Page 40 of 41
u oaga,
Roofing Product Control Examiner
r
f 1
•
Product Control No: 97- 0804.21
GAF Materials Corporation ACCEPTANCE NO.: 97- 0804.21
1361 Alps Road APPROVED : November 4, 1997
Wayne, NJ 07470 EXPIRES : November 4, 2000
1
NOTICE OF ACCEPTANCE STANDARD CONDITIONS
Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the
original submitted documentation, including test supporting data, engineering documents, are no older than
eight (8) years.
2 Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the
following statement: "Metro -Dade County Product Control Approved ", or as specifically stated in the
specific conditions of this Acceptance.
3 Renewals of Acceptance will not be considered if:
a) There has been a change in the South Florida Building Code affecting the evaluation of this product and
the product is not in compliance with the code changes;
b) The product is no longer the same product (identical) as the one originally approved; •
c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the
correct installation of the product;
d) The engineer who originally prepared, signed and sealed the required documentation initially submitted,
is no longer practicing the engineering profession.
4 Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically
be cause for termination of this Acceptance, unless prior written approval has been requested (through the
filing of a revision application with appropriate fee) and granted by this office.
5 Any of the following shall also be grounds for removal of this Acceptance:
a) Unsatisfactory performance of this product or process;
b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other
purposes.
6 The Notice of Acceptance number preceded by the words Metro -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is
displayed, then it shall be done in its entirety.
7 A copy of thi Acceptance as well as approved drawings and other documents, where it applies, shall be
provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site
at all times. The copies need not be resealed by the engineer.
8 Failure to comply with any section of this Acceptance hall be cause for termination and removal of
Acceptance.
9 This Acceptance contains pages I through 41
END OF THIS ACCEPTANCE
Page 41 of 41
oaga,
Roofing Product Control Examiner
•
•
.75
t1
1/4
./sq
. /sq
1.2
(12
50
)lied
dry
t 50
•rigs,
(12
it 50
?ries,
nils).
3t 50
t 1.2
at 1
it 1.2
mils).
yfoam
ilors),
1 -1/4
ied at
s).
yfoam
al /sq/
pplied
a
ROOF COVERING MATERIALS (TEVT)
ROOFING SYSTEMS (TGFU) Continued
Foam: "Poly -Iso" or "Poly -Iso Special" with "Polyfoam 251" or "Polyfoam
303 ", 1 in. min.
Base Coat One or two applications "Gacoftex UB- 7050 ", applied at 1
gal/sq/application or three applications, applied 1 -1/4 gal /sq /application
(16 -32 dry mils).
Surfacing: "Gacoftex UA -65" Series (various colors), applied 1 gal /sq (12
dry mils).
30. Deck: NC Incline: 1/2
Foam: "Poly -Iso" or "Poly -Iso Special" with "Polyfoam 251" or "Polyfoam
303 ", 1 in. min.
Base Coat One or two applications "Gacoftex UB- 7050 ", applied at 1
gal /sq /application or three applications, applied 1 -1/4 gal /sq /application
(16 -32 dry mils).
Surfacing: "Gacoftex UA -60" Series (various colors), applied 1 gal /sq (15
dry mils).
31. Deck: NC Incline: 2
Foam: "Poly -Iso" or "Poly -Iso Special" with "Polyfoam 251" or " Polyfoam
303 ", 1 in. min.
Base Coat "GacoSil 5- 1000 ", applied at 1 gal /sq (10 dry mils).
Surfacing: "Gacoftex S- 1000 ", applied at 1 gal /sq (10 dry mils).
32. Deck: NC Incline: 1
Foam: "Polyfoam 251" or "Polyfoam 303 ", any thickness.
Surfacing: "Gacoftex Ure- Shield 7007 ", 40 dry mils. .
33. Deck: NC Incline: 2 -1/2
Foam: "Polyfoam 275 ", any thickness.
Base Coat: "Gacoftex A- 6211 ", 1 -1/2 gal /sq (14 dry mils).
Surfacing: "Gacoftex A- 6200" series (various colors), 1 -1/2 gal /sq (14
dry mils).
GAF MATERIALS CORP R1306 (N)
1361 ALPS RD, WAYNE NJ 07470
"RUBEROID 20" or "RUBEROID Modified Base Sheet" may be utilized as an
alternate to Type G2 base sheets in any of the following Classifications.
1/2 in. thick (min) gypsum board or 1/4 in. thick (min) Georgia - Pacific
"Dens - Deck®" overtayment board may be used in any existing noncombustible
deck Classification. When this is done, the resulting roofing system is
acceptable for use over combustible (15/32 in. min) roof decks. The joints in
the gypsum board and overtayment board are offset 6 in. with the joints in the
deck. If polystyrene is part of the roof system, it must be placed below the
overtayment board.
ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT
Type G2 asphalt glass mat base sheet ( "GAFGLAS #75 Base Sheet") is a
suitable alternate for Type G1 asphalt glass fiber ply sheet ( "GAFGLAS Ply 4" or
"GAFGLAS Ply 6 ") in the Class A, B or C roof systems indicated below.
The roof deck may first be covered with a Type G2 asphalt glass mat base
sheet "GAFGLAS Stratavent (Vent -Ply) perforated" or "GAFGLAS Stratavent
(Vent -Ply) for nailable decks ". Perforated to be mopped and nailable to be
mechanically attached granule side down.
As an option Type G2 asphalt glass mat base sheet ( "GAFGLAS #75 Base Sheet"
or "GAFGLAS Stratavent (Vent -Ply) for nailable decks ") may be substituted for
G1 asphalt glass fiber ply sheet ( "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ") as the
nailed base ply in the following systems.
Bottom ply or base sheet may be solid mopped, spot mopped or mechanically
fastened.
Unless otherwise indicated, all insulations may be hot mopped or mechanically
fastened.
"GAFGLAS Flashing" or "Ruberoid" may be used for flashing in any of the Class
A, B or C systems listed below.
When "perlite" is referenced, this includes "GAFTEMP PERMALITE®" or any
other UL Classified perlite insulation.
Crushed stone or slag are suitable alternates for gravel in any of the Class A,
B or C systems listed.
Structural cement fiber building units are considered suitable to be included
as a deck in the following Class A, B or C systems listed over C -15/32 or NC.
The use of gypsum board under any of the following Class A, B or C systems
does not adversely effect the rating. The use of 1/2 in. min gypsum board is
an acceptable alternate for insulation over C -15/32 decks.
The use of polystyrene insulation board between min 3/4 in. perlite board
and deck with rosin paper (perlite /rosin paper /polystyrene /perlite) is a
suitable alternate for isocyanurate board in the following Class A, B or C
systems.
"GAFTEMP Isotherm RA ", " GAFTEMP Tapered Isotherm RA" and "GAFTEMP
Composite A" may be substituted for any isocyanurate insulation in any of the
following Classifications.
Class A, B and C.
Hot roofing asphalt, for use with organic and glass felts or modified bitumen
membranes.
Class A
1. Deck: C -15/32 Incline: 3
Insulation (Optional): One or more layers perlite, wood fiber, glass
fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/
LOOK FOR MARK ON PRODUCT
ROOF COVERING MATERIALS (TEVT) 135
ROOFING SYSTEMS (TGFU) — Continued
urethane composite, wood fiber /isocyanurate composite, phenolic, any
thickness.
Ply Sheet: Three or more layers Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply
6 ", hot mopped.
Surfacing: Gravel.
2. Deck: C -15/32 Incline: 2
Insulation (Optional): One or more layers perlite, wood fiber, glass
fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/
urethane composite, wood fiber /isocyanurate composite, phenolic, any
thickness.
Ply Sheet Three or more layers Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply
6 ".
Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheet ".
3. Deck: NC Incline: 2
Insulation (Optional): One or more layers perlite, wood fiber, glass
fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/
urethane composite, wood fiber /isocyanurate composite, phenolic, 2 in.
max.
Ply Sheet: Two or more layers Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply
6".
Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheet".
4. Deck: NC Incline: 1/2
Insulation: One or two layers "Isotherm R ", 4 in. max, hot mopped.
Ply Sheet: Any UL Classified gravel surfaced Class A asphalt glass fiber
mat system.
5. Deck: C -15/32 Incline: 1
Slip Sheet (Optional): Red rosin paper, nailed to deck.
Base Sheet: One layer of Type G2 "GAFGLAS #75 Base Sheet" (may be
nailed).
Ply Sheet: One or more layers of Type G1 "GAFGLAS Ply 4" or GAFGLAS Ply
6 ".
Cap Sheet: One layer of Type G -3 "GAFGLAS Mineral Surfaced Cap Sheet".
6. Deck: NC • Incline: 3
Base Sheet: One layer of Type G2 "GAFGLAS #75 Base Sheet".
Ply Sheet: One or more layers of Type G1 "GAFGLAS Ply 4" or GAFGLAS Ply
6 ".
Cap Sheet: One layer of Type G -3 "GAFGLAS Mineral Surfaced Cap Sheet ".
7. Deck: C -15/32 Incline: 2
Insulation: One or more layers perlite, glass fiber, isocyanurate, urethane,
perlite /isocyanurate composite, perlite /urethane composite, phenolic,
1.0 in. min (offset from plywood joints 6 in.).
Base Sheet: One or more layers of Type G1, G2 or G3.
Membrane: One or more layers of "Ruberoid Torch" (smooth or granule),
"Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or
"Ruberoid Mop Plus" (granule).
Cap Sheet: "GAFGLAS Mineral Surfaced Cap Sheet", hot mopped.
8. Deck: C -15/32 Incline: 2
Insulation (Optional): One or more layers perlite, wood fiber, glass
fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/
urethane composite, wood fiber /isocyanurate composite, phenolic, any
thickness.
Base Sheet: Two or more layers of Type G2 or G3.
Ply Sheet (Optional): One or more layers of Type GI.
Membrane: One or more layers of "Ruberoid Torch" (smooth or granule),
"Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or
"Ruberoid Mop Plus" (granule).
Cap Sheet: "GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped.
Class B
1. Deck: C -15/32 Incline: 3 -1/2
Insulation (Optional): One or more layers perlite, wood fiber, glass
fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/
urethane composite, wood fiber / isocyanurate composite, phenolic, any
thickness.
Ply Sheet: Two or more layers of Type G1 "GAFGLAS Ply 4" or " GAFGLAS
Ply 6"
Cap Sheet: Type G3 "GAFGLAS Mineral Surfaced Cap Sheet", hot mopped.
2. Deck: C -15/32 Incline: 3 -1/2
Insulation (Optional): One or more layers perlite, wood fiber, glass
fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/
urethane composite, wood fiber /isocyanurate composite, phenolic, any
thickness.
Base Sheet: Two or more layers of Type GI, G2 or G3.
Membrane: One or more layers of "Ruberoid Torch" (smooth or granule),
"Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or
"Ruberoid Mop Plus" (granule).
Cap Sheet: "GAFGLAS Mineral Surfaced Cap Sheet", hot mopped.
Class C
1. Deck: C -15/32 Incline: 1/2
Insulation (Optional): One or more layers perlite, wood fiber, glass
fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite]