Loading...
1998 Mechanical permitPERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date S c:2- 8' Job Address D.6. . 'a 51 Tax Folio Legal Description Historically Designated: Yes No Owner/Lessee / TenanCA-Ta L 0 414 — V 5 C., O Master Permit # $ Owner's Address S A). e • I Z 6r Phone C 06) 7 6-1- 7614 Contracting Co. Q 2 e 11O 440 e Address /ND .c c) J.i ; s"7' .' Queer 6772? / 2 ° f v 2. SS# Phone C ®0 e4YcZ,y State # Municipal # Competency # Ins. Co. Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN �J WORK DESCRIPTION g/ 3 '/ '"� � a>9 �� ©� s� �— ��iA�,��'� ® � a�- Square Ft. Estimated Cost (value) ,? Czc a) WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY OF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDA ► I certify that all - foregoing information is accurate and that all work will be done in compliance with all applicable laws regul g ••ns ,� do f. • • . F � a ore I . • orize the above -named contractor to do the work stated. Signatures wan• 'C o •7'resi•� SiggatureofContract• O w n er- Build �► l rr A ANE NEM 0 CC /22,1) • i coMmussioN CC y'12 r 1 er Is COmmiSSON MOO 1AAR NM �,� fxPis�neeMAcR 8, 2002 No td4ANI� • • j sident Date Nary a I�'Cemedu - - -, y j e r My Commission Expires: APPROVED: Zoning Mechanical Date My Commission Expires: FEES: PERMITX q ' 50 RADON C.C.F. t � g NOTARY BOND g/0 Date Date ding Electrical I F / slumbing Engineering a ELL 005" 3tal 1150 S.W. 22 St. Suite 10 Miami, FL 33129 INSTALLATION & REPAIR COMMERCIAL AND RESIDENTIAL LICENSED & INSURED PORI Alt LUIS ALVAREZ Sales Manager Tel: (305) 854 -6380 Beep: (305) 363 -4158 • r property tine 9' drain line: 3/8" OD insulated with 2 / orrna flex 3/8x 1/2" through attic to outside anchored to concrete, slab. SEE A-.4 - • 4 "• / • / • / • / • rAMILY ROOM 285CFM 10X8" Ylex.05 " / KITCHEN 153CFM 1CX6 1 CV 1.— • ea VI CV tr) Z< co 0 0 CV OD • • • K) 't •d = < — Lr, m cc co ei az • • aw Vfr LJDI • z 00 <i,j V) V) 0 0 0 0 c 0 a_ r c c • cq > 1— L. 1i) ▪ LJ L a. 7- 00 (0 Z - 2 o < 0 0 -3 5 cc 0 refrigeronl 3/5" 09 suction: 7/8" OD insulalea with arrnoflex 718s,: 1/2" through attic to C/U BATH LIVING ROOM 186CFM BATH 2 T 10X8” BECROOM 1 281CFM 10X8" .-reiurn:18x20 prig' , wall type I ,fIe.� 12 . / flex. 06" 135CFM 10X6" DINING FCCM 186CFM 23' 10X8" 21 39' • W KCCWS SCHEDULE: 36 S.F. ')! 24 S.F. „-„ \ 3 / '5 S.F. 4 12 5.- ALL DUCT WORK TO EE R-6 ALL DIFFUSERS ARE CEILING TYPE DRAIN PUMP INSTALLED BY MANUFACTURER RECOMMENDATIONS. iA—A CCNDENSING 4 anchor bolts UNIT 3/5" x 1-1/2" \ . Vrolitilka \-concrete slab 4" Outside db: Inside db: Design TD: For: CATULO PALAU VELAZCO 500 NORTH EAST 92nd AVE. MIAMI SHORES FL 305- 759 -7624 By: WINTER DESIGN CONDITIONS SUMMER DESIGN CONDITIONS HEATING SUMMARY Bldg. Heat Loss Ventilation Air Vent Air Loss Design Heat Load Space Thermostat INFILTRATION RIGHT -J LOAD AND EQUIPMENT SUMMARY PORTO AIR CONDITIONING 1150 SOUTH WEST 22nd ST. # 10 MIAMI FL 305- 796 -8893 47 Deg F 70 Deg F 23 Deg F 35864 Btuh 0 CFM 0 Btuh 35864 Btuh Const Qual a # Fireplaces 0 HEATING COOLING Area (sq.ft.) 1658 1658 Volume (cu.ft.) 13761 13761 Air Changes /Hour 0.8 0.4 Equivalent CFM 184 92 HEATING EQUIPMENT SUMMARY Make AMANA Model Type Efficiency / HSPF 0.0 Heating Input 0 Btuh Heating Output 0 Btuh Heating Temp Rise 0 Deg F Actual Heating Fan 1400 CFM Htg Air Flow Factor 0.039 CFM /Btuh Job #: Wthr : Miami_AP_(S) Zone : Outside db: Inside db: Design TD: Daily Range Rel. Hum. . Grains Water SENSIBLE COOLING EQUIP LOAD SIZING Structure 29122 Btuh Ventilation 0 Btuh Design Temp. Swing 3.0 Deg F Use Mfg. Data n Rate /Swing Mult. 0.95 Total Sens Equip Load 27666 Btuh LATENT COOLING EQUIP LOAD SIZING Internal Gains 920 Btuh Ventilation 0 Btuh Infiltration 3501 Btuh Tot Latent Equip Load 4421 Btuh Total Equip Load 32087 Btuh COOLING EQUIPMENT SUMMARY Make AMANA Model C /U:RCE42A2A Type A /H:BBA48 /CHA42 COP /EER /SEER Sensible Cooling Latent Cooling Total Cooling Actual Cooling Fan Clg Air Flow Factor Load Sens Heat Ratio 90 Deg F 75 Deg F 15 Deg F L 50 % 56 gr 14.6 30500 Btuh 11500 Btuh 42000 Btuh 1400 CFM 0.048 CFM /Btuh 87 MANUAL J: 7th Ed. RIGHT -J: V1.72 Printout certified by ACCA to meet all requirements of Manual Form J 8 -20 -98 FL RIGHT -J CALCULATION PROCEDURES A,B,C,D Job #: 8 -20 -98 Procedure A - Winter Infiltration HTM Calculation* 1. Winter Infiltration CFM 0.8 AC /HR x 13761 Cu.Ft. x 0.0167 184 CFM 2. Winter Infiltration Btuh 1.1 x 184 CFM x 23 Winter TD = 4651 Btuh 3. Winter Infiltration HTM 4651 Btuh / 270 Total Window = 17.2 HTM & Door Area Procedure B - Summer Infiltration HTM Calculation* 1. Summer Infiltration CFM 0.4 AC /HR x 13761 Cu.Ft. x 0.0167 92 CFM 2. Summer Infiltration Btuh 1.1 x 92 CFM x 15 Summer TD = 1517 Btuh 3. Summer Infiltration HTM 1517 Btuh / 270 Total Window = 5.6 HTM & Door Area Procedure C - Latent Infiltration Gain 0.68 x 56 gr.diff. x 92 CFM = 3501 Btuh Procedure 0 - Equipment Sizing Loads 1. Sensible Sizing Load Sensible Ventilation Load 1.1 x 0 Vent.CFM x 15 Summer TD = 0 Btuh Sensible Load for Structure (Line 19) + 29122 Btuh Sum of Ventilation and Structure Loads = 29122 Btuh Rating and Temperature Swing Multiplie x 0.95 RSM Equipment Sizing Load - Sensible + 27666 Btuh 2. Latent Sizing Load Latent Ventilation Load 0.68 x 0 Vent.CFM x 56 gr.diff. = 0 Btuh Internal Loads = 230 x 4 No. People + 920 Btuh Infiltration Load From Procedure C + 3501 Btuh Equipment Sizing Load - Latent = 4421 Btuh *Construction Quality is: a No. of Fireplaces is: 0 MANUAL J: 7th Ed. RIGHT -J: V1.72 TR Printout certified by ACCA to meet all requirements of Manual Form J 16 17 18 19 20 Job #: Zone: MANUAL J: 7th Ed. - - -- RIGHT -J: V1.72 11 Name of Room 1 Entire 2) Running Ft. Exposed Wall 1 212 31 Room Dimensions, Ft. 1 41 Ceilngs,Ft 1 Condit. Option' 8.3 1 9 5 6 7 111 Floors 1 1 TYPE OF f 'CST' HTM 1 Area 1 Btuh EXPOSURE { IN0.1Htg 1C1g {Length' Htg I Clg Gross Exposed Walls and Partitions Windows & Glass Doors Htg. Windows & Glass Doors Clg. Net Exposed Walls and Partitions 10) Ceilings a b c d e f 14A al 1F bl cl dl el fl North NE &NW E &W SE &SW South Horz 11.7 0.0 0.0 0.0 0.0 0.0 24.6 0.0 0.0 0.0 0.0 0.0 7.8 0.0 0.0 0.0 0.0 0.0 12.8 0.0 43.1 0.0 17.0 0.0 8) Othr doors Ia'l0D110.6110.4 Ibl 1 0.01 0.0 a 14A 11.7 7.8 b 0.0 0.0 c 0.0 0.0 d 0.0 0.0 e 0.0 0.0 f 0.0 0.0 IaI16DI 1.21 2.3 }b) 1 0.01 0.0 ICI 1 0.01 0.0 IaI22A118.6) 0.0 Ibl 1 0.01 0.0 )c) 1 0.01 0.0 12) Infiltration a 117.21 5.6 131Subtot Btuh Loss=6 +8.. +11 +12 141 Duct Btuh Loss 151 Total Btuh Loss = 13 +14 Int. Gains: People 0 300 Appl. 0 1200 Subtot RSH Gain =7 +8.. +12 +16 Duct Btuh Gain Total RSH Gain = 17 +18 CFM Air Required Printout certified by ACCA to 1760 0 0 228 0 0 0 0 0 30 0 162 0 36 0 1490 0 0 0 0 0 0 0 0 5616 0 0 421 4441 437 01 01 0 17473 0 0 0 0 0 0 0 0 16581 20211 3779 0 1 01 0 0 1 01 0 2121 39501 Of 01 01 01 House 0 Ft. 11623 270) 46511 1517 * * ** 1 341561 * * ** 5 %1 17081 * * ** * * ** 1 358641 * * ** 384 6984 0 612 0 0 0 0 0 0 0 0 0 0 8 -20 -98 TR - -- Page 1 - - -- FAMILY ROOM 58.0 Ft. 14.0 x 24.0 Ft. 8.3 1 heat /cool Area 1 Btuh Length) Htg 1 Clg 481 0 60 0 0 0 0 0 12 0 12 0 36 0 400 0 0 0 0 0 0 0 0 0 1478 211 222( 218 0 1 Of 0 4697 0 0 0 0 0 0 0 3361 4101 766 01 01 0 01 01 0 581 10811 01 01 01 01 0 0 0 3124 0 0 0 0 0 811 13951 455 * * ** 1 9282) * * ** 5 %I 4641 * * ** * * ** I 97471 * * ** 132 0 384 0 612 0 0 0 0 1200 01 * * ** 0 1200 01 * * ** 0 27735 * * ** I * * ** 5691 1387 5 %1 * * ** 285 29122 * * ** 1 * * ** 5976 1400 1400 * * ** 1 380 287 meet all requirements of Manual Form J -- Job #: Zone: MANUAL 3: 7th Ed. - - -- RIGHT -J: V1.72 - - -- 11 Name of Room I KITCHEN 21 Running Ft. Exposed Wall 1 16.0 Ft. 31 Room Dimensions, Ft. 1 12.0 x 12.0 Ft. 41 Ceilngs,Ft 1 Condit. Option 8.3 1 heat /cool 5 6 7 9 TYPE OF 1 ICSTI HIM I Area I EXPOSURE I INO.'Htg IC1g 1Length! Gross Exposed Walls and Partitions Windows & Glass Doors Htg. Windows & Glass Doors Clg. 111 Floors a 14A 11.7 b 0.0 c 0.0 d 0.0 e 0.0 f 0.0 7.8 0.0 0.0 0.0 0.0 0.0 a 1F 24.6 ** b 0.0 ** c 0.0 ** d 0.0 ** e 0.0 ** f 0.0 ** North NE&NW E &W SE &SW South Horz 12.8 0.0 43.1 0.0 17.0 0.0 81 Othr doors Iall0DI10.6110.4 Ib1 1 0.01 0.0 Net a 14A 11.7 7.8 Exposed b 0.0 0.0 Walls and c 0.0 0.0 Partitions d 0.0 0.0 0.0 0.0 f 0.0 0.0 101 Ceilings 1a116DI 1.21 2.3 Ib1 1 0.01 0.0 Ic1 1 0.01 0.0 Ia122A118.61 0.0 Ib1 1 0.01 0.0 1d1 1 0.01 0.0 121 Infiltration a 117.21 5.6 131Subtot Btuh Lose= 6 +8.. +11 +12 141 Duct Btuh Loss 151 Total Btuh Loss = 13 +14 161 Int. Gains: People @ 300 1 Appl. @ 1200 171 Subtot RSH Gain= 7 +8.. +12 +16 181 Duct Btuh Gain 1111 SH_Total R Gain = 17 +18 AcrMf by A('.f:A t 133 0 0 0 0 0 12 0 0 0 0 0 0 0 12 0 0 0 01 0I 121 0 0 0 0 0 Btuh Htg { Clg 296 0 0 0 0 0 1417 0 0 0 0 0 161 2981 01 01 01 01 0 0 528 0 0 0 0 1 01 943 0 0 0 0 0 1441 1761 328 01 01 0 01 01 0 121 2071 67 * * ** I 23931 * * ** 5 %1 1201 * * ** * * ** 1 25131 * * ** 0 0 0 1 0 1 1200 1 3066 8 -20 -98 TR - -- Page 2 - - -- DINING ROOM 12.0 Ft. 12.0 x 12.0 Ft. B.3 I heat /cool Area 1 Btuh Length' Htg 1 Clg 100 0 0 0 0 0 24 0 0 0 0 0 0 0 24 0 0 0 76 0 0 0 0 0 591 0 0 0 0 0 887 0 0 0 0 0 121 2241 01 01 01 01 * * ** 1 22911 5 %1 1151 * * ** 1 24051 0 0 1056 01 01 0 01 01 0 590 0 0 0 0 0 0 0 0 1441 1761 328 01 01 0 01 01 0 0 0 0 241 4131 135 01 �1 * * ** 1 11 01 * * ** 1 * * ** 1 * * ** 1 * * ** 1 5%1 1 153 5$1 * * ** 1 135 * * ** 3220 * * ** * * ** 1____2844 ili nual Arm 3 371 600 0 2709 Job #: Zone: MANUAL J: 7th Ed. - - -- RIGHT -J: V1.72 - - -- 11 Name of Room 1 LIVING ROOM 21 Running Ft. Exposed Wall 1 42.0 Ft. 31 Room Dimensions, Ft. 1 16.0 x 25.0 Ft. 41 Ceilngs,Ft 1 Condit. Option' 8.3 I heat /cool 5 6 7 9 TYPE OF I ICSTI HTM 1 Area I Btuh EXPOSURE i IN0.1Htg IClg ILengthl Htg I Clg Gross Exposed Walls and Partitions Windows & Glass Doors Htg. Windows & Glass Doors Clg. a 14A 11.7 7.8 b 0.0 0.0 c 0.0 0.0 d 0.0 0.0 e 0.0 0.0 f 0.0 0.0 a 1F 24.6 ** b 0.0 ** c 0.0 ** d 0.0 ** e 0.0 ** f 0.0 ** North 12.8 NE&NW 0.0 E &W 43.1 SE &SW 0.0 South 17.0 Horz 0.0 81 Othr doors la110D110.6110.4 Ibl 1 0.01 0.0 Net Exposed Walls and Partitions 111 Floors 1 1 a b c d e f 14A 11.7 0.0 0.0 0.0 0.0 0.0 7.8 0.0 0.0 0.0 0.0 0.0 101 Ceilings IaI16DI 1.21 2.3 1 Ib1 1 0.01 0.0 1 1cl 1 0.01 0.0 lal22A118.61 0.0 Ibi 1 0.01 0.0 Icl 1 0.01 0.0 121 Infiltration a 117.21 5.6 13ISubtot Btuh Loss =6 +8.. +11 +12 141 Duct Btuh Loss 151 Total Btuh Loss = 13 +14 349 0 0 0 0 0 72 0 0 0 0 0 0 0 72 0 0 0 256 0 0 0 0 0 1774 0 0 0 0 0 211 2221 218 01 01 0 2998 0 0 0 0 0 0 0 3168 0 0 0 1994 0 0 0 0 0 4001 4881 912 01 01 0 01 01 0 421 7821 01 01 01 01 0 0 0 931 16021 522 * * ** 1 78661 * * ** 5 %1 3931 * * ** * * ** 1 82591 * * ** 8 -20 -98 TR - -- Page 3 - - -- BEDROOM 1 61.0 Ft. 13.0 x 24.0 Ft. 8.3 I heat /cool Area 1 Btuh Length' Htg I Clg 506 * * ** * * ** 0 * * ** * * ** 0 * * ** * * ** 0 * * ** * * ** 0 * * ** * * ** 0 * * ** * * ** 36 887 * * ** O 0 * * ** 0 0 * * ** O 0 * * ** 0 0 * * ** O 0 * * ** 18 * * ** 252 0 * * ** 0 18 * * ** 792 0 * * ** 0 O * * ** 0 0 * * ** 0 01 01 0 01 01 0 470 5517 3670 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3121 3801 711 01 01 0 01 01 0 611 11361 0 01 01 0 01 01 0 361 6201 202 * * ** 1 85401 * * ** 5 %1 4271 * * ** * * ** 1 89671 * * ** 0 * * ** 0 0 * * ** 0 * * ** * * ** 5627 5% * * ** 281 16 Int. Gains: People @ 300 2 * * ** I 600 Appl. @ 1200 0 * * ** I 0 17 Subtot RSH Gain =7 +8.. +12 +16 * * ** * * ** I 7415 18 Duct Btuh Gain 5% * * ** 1 371 19 Total RSH Gain = 17 +18 * * ** * * ** 1 7786 20 CFM Air Required * * ** 3221 374 - -- Printout certified by ACCA to meet all requirements of Manual Form J -- * * ** * * ** 5908 * * ** 350 284 Job #: Zone: MANUAL J: 7th Ed. - - -- RIGHT -J: V1.72 - - -- 11 Name of Room I BEDROOM 2 21 Running Ft. Exposed Wall 1 23.0 Ft. 31 Room Dimensions, Ft. 1 14.0 x 23.0 Ft. 41 Ceiings,Ft I Condit. 0ptionl 8.3 1 heat /cool 16 17 18 19 20 6 7 9 5 TYPE OF 1 ICSTI HTM 1 Area 1 Btuh EXPOSURE 1 INO.IHtg Clg 'Length) Htg 1 Clg Gross Exposed Walls and Partitions Windows & Glass Doors Htg. Windows & Glass Doors Clg. 101 Ceilings 81 Othr doors lall0D110.6110.4 lbl 1 0.01 0.0 Net Exposed Walls and Partitions 111 Floors a 14A 11.7 7.8 b 0.0 0.0 c 0.0 0.0 d 0.0 0.0 e 0.0 0.0 f 0.0 0.0 a IF 24.6 ** b 0.0 ** c 0.0 ** d 0.0 ** e 0.0 ** f 0.0 ** North 12.8 NE&NW 0.0 B &W 43.1 SE &SW 0.0 South 17.0 Horz 0.0 a b c d e f 14A111.7 1 0.0 1 0.0 1 0.0 1 0.0 1 0.0 7.8 0.0 0.0 0.0 0.0 0.0 IaIl6D1 1.21 2.3 Ibl 1 0.01 0.0 IdI 1 0.01 0.0 1aI22A118.61 0.0 Ibl 1 0.01 0.0 Id! 1 0.01 0.0 121 Infiltration a 117.21 5.6 13lSubtot Btuh Loss =6 +8..+11 +12 141 Duct Btuh Loss 151 Total Btuh Loss = 13 +14 Int. Gains: People @ 300 Appl. @ 1200 Subtot RSH Gain =7+8.. +12 +16 Duct Btuh Gain Total RSH Gain = 17 +18 CFM Air Required Printout certified by ACCA to 191 * * ** * * ** O * * ** * * ** 0 * * ** * * ** 0 * * ** * * ** 0 * * ** * * ** O * * ** * * ** 24 5911 * * ** O 01 * * ** 0 01 * * ** O 01 * * ** 0 01 * * ** 0 01 * * ** 155 0 0 1056 01 01 0 01 01 0 167 1958 1302 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3221 3931 734 01 01 0 01 01 0 231 4281 0 01 01 0 01 01 0 241 4131 135 * * ** 1 37831 * * ** 5 %1 1891 * * ** * * ** 1 39731 * * ** 0 0 3227 161 3388 163 0 0 0 8 -20 -98 TR - -- Page 4 - - -- Area 1 Btuh Length) Htg 1 Clg x Ft. Ft. all requirements of Manual Form J -- MANUAL J: 7th Ed. RIGHT -J: V1.72 TR RIGHT -J WINDOW DATA Job #: 8 -20 -98 W S D W G L S S O N A S O 0 W C W S N K IA L O T H V G N H V V H H N H D Y R L A W R A H L G C R R G T A A W L Z E M D G Z L O X Y T M R R FAMILY ROOM a n s a r y n b n 1 90 1.0 0.0 0.0 1.0 17.0 36.0 0.0 a n e a r y n b y 1 90 1.0 8.0 0.0 3.0 32.0 12.0 12.0 a n w a r y n b n 1 90 1.0 0.0 0.0 1.0 32.0 12.0 0.0 KITCHEN a n w a c y n b n 1 90 1.0 0.0 0.0 1.0 44.0 12.0 0.0 DINING ROOM a n w a c y n b n 1 90 1.0 0.0 0.0 1.0 44.0 24.0 0.0 LIVING ROOM a n e a c y n b n 1 90 1.0 0.0 0.0 1.0 44.0 36.0 0.0 a n w a c y n b n 1 90 1.0 0.0 0.0 1.0 44.0 36.0 0.0 BEDROOM 1 a n e a c y n b n 1 90 1.0 0.0 0.0 1.0 44.0 18.0 0.0 a n n a c y n b n 1 90 1.0 0.0 0.0 1.0 14.0 18.0 0.0 BEDROOM 2 a n e a c y n b n 1 90 1.0 0.0 0.0 1.0 44.0 24.0 0.0