BPP-07-1706 (2)NL TFL TUP LIF POOL ELEVATION IS MIN. 6" LOWER THAN F.F.E. OF HOUSE PUMP FRAME, FILTER TANK MOUNT 7-1 3/4" x 3/16" TAP CON. ",,■- REINFORCED CONC. SLAB -II11 =1111 11111 1111 I I1= 1111 = 11111 = 11111111 FILTER z din" id r EXISTING ELECT. PANEL/ METER n 's —° MAINTAIN MIN. SETBACKS PER CODE - LANDSCAPE SCREEN PER CODE - 1 CONC. PAD FOR EQUIPMENT - SIZE TO BE DETERMINED IN FIELD - SEE PAD DETAIL FOR THICKNESS AND REINFORCEMENT PAGE I 4/Se v� FOR POOL LOCATIO\ 0 S IF PLA\ NORTH ARROW SCALE : 1"= 20' \LY RUDNICK RESIDENCE 544 N.E. 93rd STREET MIAMI SHORES, FLORIDA 6' X 6" X 1.4" W.W.F. z f EQUIPMENT PAD SIZE TO BE DETERMINED IN FIELD EQUIPMENT PAD DETAIL N.T.S. BARRIER NOTE: OUTDOOR SWIMMING POOLS AND SPAS SHALL BE PROVIDED WITH A PERMANENT BARRIER THAT SHALL BE INSTALLED, INSPECTED & APPROVED PRI ❑R TO PLASTERING OR FILLING WITH WATER. SUCH PERMANENT BARRIER SHALL BE IN ACCORDANCE WITH SECTI ❑N F.B.C. LATEST EDITION,. SPECIAL PROVISI ❑NS: 1. ALL SWIMMING POOLS, SPAS AND HOT TUB AREAS SHALL BE PROVIDED WITH A PERMANENT SAFETY WARNING SIGN IN READILY VISIBLE L ❑CATI ❑N FROM THE POOL AREA (APPENDIX F ANSI - NSPI -5 -95) 2, EACH SAFETY WARNING SIGN SHALL WARN AGAINST SHALLOW WATER DIVING, PREVENTI ❑N OF DROWNING & INCLUDE THE FOLLOWING STATEMENT: "THERE IS NO SUBSTITUTI ❑N FOR ADULT SUPERVISION OF SMALL CHILDREN. IT IS STRONGLY RECOMMENDED THAT AT LEAST ONE ADULT RENDERING CHILD SUPERVISI ❑N BE TRAINED IN ARTIFICIAL RESPRATI ❑N AND/OR CARDI❑PULM ❑NARY RESUSCITATION (CPR)" HYDRAULIC UPLIFT C[1M4FUTA T IDNS FLOOD CREST ELV. FOR AREA = 8,00' TOP OF POOL ELV. = 10.15' BOTTOM OF POOL ELV. = 4.15' HYDRAULIC HEAD = 3.85' ALLOWANCE HYDROSTATIC VALVE = -2.0' NET HYDRAULIC HEAD = 1.85' MSL MSL MSL USE MIN, 8' THICK CONCRETE FLOOR SLAB LEGAL DESCRIPTIDN LOT: 4 & 5 & 20' OF WEST SIDE OF LOT 3 BLK: 57 SUBDIVISI ❑N: MIAMI SHORES SEC. NO, 2 PLAT BOOK: 10 PG:37 PUBLIC RECORD OF MIAMI -DADE COUNTY, FL. (2) 8" ANTI VORTX SPA MAIN DRAINS ALSO UTILIZED AS SPILLWAY RETURNS MIN. 3' APART ALARM NOTE: ALL WALLS THROUGH WHICH A DOOR PROVIDES ACCESS TO THE POOL SHALL BE EQUIPPED WITH AN ALARM AUDIBLE WARNING WHEN THE DOOR OR ITS SCREEN IS BEING OPENED. THE ALARM SHALL SOUND CONTINUOUSLY FOR A MIN. 30 SECONDS AFTER THE DOOR IS OPENED AND BE CAPABLE OF EMITTING A SOUND OF SUFFICIENT VOLUME TO BE HEARD WITHIN THE DWELLING, THE ALARM SHALL BE EQUIPPED WITH A MANUAL MEANS TO TEMPORARLY DEACTIVATE THE ALARM FOR A SINGLE OPENING. THE DEACTIVATION SWITCH SHALL BE LOCATED AT LEAST 54" ABOVE THE THRESHOLD OF THE THE DOOR, NOTE: LAYOUT OF POOL AND HOUSE DRAWN BY SUBMITTAL OF SURVEY FROM THE POOL CONTRACTOR. TWENTY FIRST CENTURY ENGINEERING IS NOT RESPONSIBLE FOR ANY DISCREPANCIES DUE TO ANY ILLEGIBLE DIMENSIONS OR UTILITIES NOT SHOWN ON SURVEY. CONSTRUCTION NOTES (1) POOL LOCATION MUST COMPLY WITH N.E.C. (ARTICLE CO.) (58 (2) POOL PERIMETER BARRIER - EXISTING FENCE - ALARM 1 HP MANUF T.B.D. MODEL# T.B.D. SPA PLUMBING ISOMETRIC N.T.S. NOTE: ALL CONDUCTOR CLEARANCES SHALL COMPLY WITH N.E.C. 680.8 FOR OVERHEAD. AND N.E.C. 680.10 FOR UNDERGROUND. REFERENCE N.E.C. 2005 POOL PUMP, FILTER AND HEATER ANCHOR POINTS (TYP) I L .7 0 rPUMP l NOTES: ANCHOR BOLTS THROUGH BASE (1 -3/4" x 3/16" TAP CONS) FOR POOL PUMP & FILTER HEATER SHOWN AS OPTIONAL (4) 1 -1/2" ANGLE BRACKETS (GAS HEATER) (4) 2 -1/2" ANGLE BRACKETS (HEAT PUMP) WITH (4) 1 -3/4" X 3/16" WITH (4) 1 3/4" x 3/16" TAP CON AND (4) 1/2" SELF TAPPING SHEET METAL SCREWS. �-' POOL EQUIPMENT ANCH ❑RING N.T.S. '4t1r °f 114 r,, e 4r.Qesti /0-91 kr t -141»e 5 peI;), PLUG OR HYDROSTATIC VALVE i-112' ANTI VORTEX GRATE TO BE FASTENED WITH SCREWS WELL POINT KOCK BED WELL POINT DETAIL N.T.S. GROUND LEVEL, POOL DECK OK MAX. POOL WATER. LEVL,� WHICHEVER I5 GREATER 1-1/2" PVC TEE TO MATCH VENT LINE SIZE WINDOW SCREEN TYP. 2 PLACES) PVC SLEEVE PRESSED IN PLACE THE ATMOSPHERIC VENT TEE SHALL BE LOCATED NOT LESS THAN 8 ", MEASURED FROM THE BOTTOM OF THE STRAIGHT LEG OF THE TEE, ABOVE THE GROUND LEVEL, POOL DECK, OR MAXIMUM POOL WATER LEVEL, WHICHEVER PROVIDES THE GREATEST ELEVATION. ATMOSPHERIC VENT DETAIL INLINE SALT - C/L GENERATOR N.T.S. POOL SIZE: POOL PERIMETER: VOLUME: (GALLONS) POOL EQUIPMENT SPECIFICATIONS 22 ' X 34' .8 1' -9" LF 18,311 POOL PUMP: POOL FILTER: 1 C-1750 1 POOL INLETS: SKIMMER: POOL LIGHT: POOL HEATER TYPE: POOL HEATER SIZE: CLEANING LINE: CLEANING SYSTEM: CHLORINATOR: 2 11P HAYWARD I ) COLOR LED HEAT PUMP 1 13 K YES N/A SALT — C/L GEN. COPING: TILE: SWIMOUT: LADDER: HANDRAIL: AUX. POOL SPILLWAY SIZE: LIONS HEAD: SPRITZER /SPRAY HEAD: THERAPY JETS: POOL POOL DEPTH:. 1 ,Y 3' TO 6' POOL AREA SQ. FT.: TURNOVER RATE13o5 HR @ 10o GPMI AUXILLIARY POOLQU1FMENT 544 SF AUX. POOL PERIMETERc, -2? L— AUXILLIARY PUMP: AUX. POOL JETS: AUX. POOL LIGHT: AUX. HEATER TYPE: AUX. HEATER SIZE: RAISED: STEP(S): BLOWER: TURNOVER RATE: FINISH ITEMS HANDHOLDS: INTERIOR FINISH: DECK S.F.: CAPPING S.F.: DECK TYPE: TUMBLED MARBLE 6" YES N/A N/A WATER FEATURES 30" N/A N/A 2) IN SWIMOUT FIBER OPTIC SPOT(S): PERIMETER LIGHTS: POOL ENCLOSURE: FOOTERS L.F.: DECO -O- DRAIN: PILING POOL: N/A N/A FOUNTAIN FEATURE: SHEER DESCENT: FEATURE PUMP: OTHER: LIGHT FEATURES REMOTE : LIGHT SWITCH: NO YES AS POOL 6 1)IOOW AS POOL AS POOL 12" N/A 1 HP 4 MIN. @ 40 GPM YES GEM COAT 831 5F 200 5F L PAVER N/A 1 N/A N/A N/A N/A COLOR WHEEL: # OF COLORS: ADDITIONAL FEATURES ALARM/ EXISTING FENCE N/A N/A N/A GLASS BLOCK TYPE: GLASS ROWS HT: GLASS ROWS WDTH. # OF GLASS BLOCKS. NO N/A N/A N/A N/A N/A * DOES NOT INCLUDE 8' -8" COMMON POOL/ SPA WALL UNION TYP. OF 2 BALL VALVE 3 WAY JANDY VALVE L- F IVI 113K HEAT PUMP 2 WAY JANDY W/ ACTUATOR 3 WAY JANDY W/ ACTUATOR SWING CHECK VALVE gill)I COI A2 H.P. PUMP W/ HAIR & LINT STRAINER - 94 GPM TO 112 GPM B2 H.P. BLOWER 4 LB CHECK VALVE 2' 1 FILTER 1 POOL/ SPA DRAIN -T❑ BE RETAINED ON SITE 2 H P. BLOWER (2) 8' MAIN DRAINS W/ ANTI VORTEX COVERS MINIMUM 3' APART. HANDHOLD DETAIL N.T.S. LOCATE @ WATERLINE POOL PLUMBING ISOMETRIC N.T.S. PROVIDE A HAND HOLD NO MORE THAN 9' ABOVE THE NORMAL WATER LEVEL. NOTE: CERAMIC TILE HAND HOLD MAX. SPACING SHALL NOT EXCEED 48" SWING CHECK VALVE 2' TO SPA FOR SPILLWAY 2' T ❑ POOL RETURNS 2' TO THERAPY JETS SWING CHECK VALVE 2 1/2" FROM SPA MAIN DRAINS 2" FROM POOL SKIMMER I 2 1 /2" FROM POOL MAIN DRAINS 2' VAC LINE o�— 1" VENT ED PIPING SCHEMATIC N.T.S. 2" AIR LINE TO SPA GENERAL NOTES CODE REQUIREMENTS - Private swimming pool and spas must comply with chapter' 424 & 24101. Florida Building Code, 2006, Mechanical Requirements! All piping, equipment and materials used in the plumbing system of' swimming pools (Spas) that are built in place shall conform to the F loridri Code, Plumbing. (424,2,3 & R4101.3), All piping materials shall be installed in strict ac_coPdance with the installation standards. Compliance All a H1Ss)tu r equ' pm nt or applianc s entering into the construction of' swimro ngpoot (Spas) or portions thereof shall be of a type complying with the code or of a type recommended and approved by a nationally recognized testing agency or conforming to other recognized standards acceptable to the administrative authority. Engineering Design Design, Construction and workmanship shall be in conformity with ANSI / NSPI 3,4,5, &6 2003, published by the National Spa and Pool Institute, or other accepted engineering practices. ENTRAPMENT Testing and Certification All pool and spa suction inlets shall be provided with a cover that has been tested and accepted by a recognized testing facility and comply with ANS /ASME A112.19.BM, "Suction Fittings for Use in Swimming Pools, Spas, Hot Tubs, and Whirlpool Bathtub Appliances." Exception Surface Skimmers, Safety Note: Do not use or operate pool or spa if the suction inlet fitting is missing, broken, or loose. Entrapment Avoidance If the suction inlet system, such as an automatic cleaning system, is a vacuum cleaner system which has a single suction inlet, or multiple suction inlets which can be isolated by valves, then each suction inlet shall protect against user entrapment by either an approved antivortex cover, 12' X 12' grate or larger, or other approved means per FBC 424.2.6.6.4 & R4101.6,6.4. In addition, all pools and spas shall be required to have a backup system which shall provide vacuum relief should grate covers be missing. Alternate vacuum relief devices shalt include either: 1. Approved Vacuum Release System 2. Approved Vent Piping 3. Other Approved Devices or Means Suction Inlet Per Pump! A minimum of' two suction inlets shall be provided for each pump in the suction inlet system, separated by a minimum of' 3 feet or located on two different planes} i.e., on the bottom and one on the vertical wall, or one each on two separate vertical walls. These suction inlets shall be plumbed such that water is drawn through them simultaneously through a common line to the pump, per FBC 424.2.6.6.4 & R4101.6.6.4. Cleaner Fittings: Where provided, the vacuum or pressure cleaner fitting(s) shall be located in an accessible position at least 6 inches and not greater than 12 inches below the minimum operating water level or as an attachment to the skimmer(s). All clearner suction inlets shall be protected by an approved, permanently installed, self - closing flapper, per FBC 424,2,6,6,5 & R4101.6.6.5. Valve: Valves shall be made of materials that are approved in the Florida Building code, Plumbing. Valves located under concrete slabs shalt be set in a pit having a least dimension of five pipe diameters, minimum 10 inches, fitted with a suitable cover, per FBC 424,2,8,1 & R4101.81. Waste Water Disposal! Direct or indirect connections cannot be made to existing facilities without the prior approval of the administrative authority, per FBC 424,2,10 & R4101.10. Tests: All pool piping shall be inspected and approved before cover or concealment. It shall be tested and proved tight under a static water or air pressure test of not less than 35 psi for 15 minutes. Per manufacture recommendations, no air test shall be approved for PVC pipe and fittings, per FBC 424,2.12,1 & R4101.12,1. Water Heating Equipment: Swimming pool water heating equipment shall conform to the design, construction and installation requirements in accordance with accepted engineering practices and shall bear the label of a recognized testing agency, and shall include a consideration of combustion alr, venting and gas supply requirements for water heaters Sec. 424.2,14.1 & R4101,14,1. It must contain a thermostatic or high - pressure control switch so the pool water does not exceed 104 degrees F. Sec. 424.2.14.4 & R4101.14.4. Water heating equipment shall be installed with flanges or union connections adjacent to the heater, swimming pool water heating equipment shall have an internal check valve, per FBC 412.1. Pool & spa covers: Pools amd spas with heaters shall be provided a cover or other means to reduce heat toss, per FBC 13- 612.1.ABC,2.3.2. Pool Enclosure: Residential Pools shall comply with FBC section 424.2.17.1 - 424.2.17.15 & R4101.17.1 - R4101,17,15 Ladders and Steps! All pools shall be provided with a ladder or steps In the shallow end where the water exceeds 24 inches. Where water depth exceeds 5 feet, there shall be ladders, stairs or underwa ter benches / swim outs in the deep end, per FBC 424.2.18 & R4101.18. Filters: The entire design of matched components shall have sufficient capacity to provide a complete turnover of pool water In 12 hours or less per FBC 424.2.20 & R4101.20, Pool Fittings: Pool fittings shalt be of an approved type and design as to be appropriate for the specific application, per FBC 424,2,2.1 & R4101,2.1 Per FBC 424,2.13.2 joints and connections and FBC plumbing Sec. 605,21, purple primer required on PVC piping. Skimmers: Skimmers shall be installed on the basis of one per 800 SF of' surface area or fraction thereof, per FBC 4242,21.2 & R4101.21,4, Hydrostatic Relief Device! In areas of' anticipated water table an approved hydrostatic relief device shall be installed, per FBC 424.2.21,4 & R4101.21.4. Exception is plastic liner pools, Concrete / Steel: All floors & walls of pool to be pneumatically applied concrete with a min 28 clay compressive strength of' 2500 psi. All reinforcing steel to conform to A615 grade 60. Soil Statement: Based upon rational analysis, the soil in this area has a 2000 psf bearing capacity after excavation and compaction. Should any muck, marl, or other organic soils be discovered on excavation, they should be removed in their entirety. This pool requires' 2000 psf bearing capacity. Pool Staking: This design engineer assumes no responsibility for pool construction in easements or required setback areas. Plot plans not prepared from legal surveys of the existing tot and residence are so indicated. The pool contractor shall verify all dimensions in the field and establish lot lines. The pool contractor shall establish locations of all utilities at the site. Min. clearance dimensions shall be held as required by the local regulatory agency. In general, hold a distance of 10 feet from overhead electric lines to open pool water, Existing Structures: The pool contractor shall always take all precautions to protect existing structures from failure by sheeting and /or shoring or other methods, the design engineer accepts no responsibility for the safety of existing structures. Backfill: The contractor shall backfill the pool shell with caution. The plumbing shall not be disturbed. Backfill shall be accomplished with clean construction grade fill, free of organic material and shall be placed in 12' lifts, each lift shall be compacted to 95% per ASTM D -1557, Warning: To empty pool after construction, for repairs or any other reason, the hydrostatic uplift pressures beneath the pool must be eliminated to prevent the pool from floating upward. The owner must consult a pool contractor or pool repair contractor' experienced in eliminating uplift pressures. Diving! No diving board and no diving is allowed on any pool less than 8'0" deep and specifically designed for diving. This pool is not designed for diving unless specifically stated on the site plan. Gas Piping Gas piping shall comply with the Florida Building Code, Fuel Gas Sec. 424.2.15 & R4101.15 Electrical! Electrical wiring and equipment shall comply with the 2005 National Electrical Code SEC 680. IF REQUIRED BY THE LOCAL MUNICIPALITY THE POOL/ SPA DECK SHALL BE BONDED PER 2005 NATIONAL ELECTRIC CODE SECTI ❑N 680 EQUIPOTENTIAL BONDING GRID SINGLE WIRE: PER THE BOARD OF RULES AND APPEALS MEETING ON MAY 10, 2007 AN ALTERNATIVE METHOD FOR SWIMMING POOLS AND SPA EQUIPOTENTIAL BONDING GRID OF POOLS AND SPAS WITH LIGHTS OF 15 VOLTS OR LESS OR NO LIGHTS MAY USE A SINGLE WIRE GRID (#8 AWG) WHEN INSTALLED AS FOLLOWS: THIS INCLUDES UNPAVED SURFACE AS WELL AS POURED SURFACES AND OTHER TYPES OF PAVING. 1) ATTACHED TO THE POOL REINFORCING STEEL OR COPPER CONDUCTOR GRID (SINGLE #8 AWG WIRE) AND 2) BURIED TO A MIN. DEPTH OF 4" NOT TO EXCEED 6" BELOW GRADE 3) CONNECTED BY A MIN. OF FOUR POINTS UNIFORMLY SPACED AROUND THE PERIMETER OF THE SWIMMING POOL AND OR SPA AND 4) CONNECTED TO AN EQUIPOTENTIAL GRID COPPER BARE CONDUCTOR NOT SMALLER THAN 5) CONNECTION SHALL BE MADE EXOTHERMIC WELDING OR BY LISTED PRESSURE CONNECTORS OR CLAMPS THAT ARE LABELED AS BEING SUITABLE FOR THE PURPOSE AND ARE OF STAINLESS STEEL, BRASS, COPPER, OR COPPER ALLOY AND 6) THE EQUIPOTENTIAL BONDING GRID SHALL EXTEND UNDER PAVED AND UNPAVED WALKING SURFACERS FOR ONE METER (THREE FEET) HORIZONTALLY BEYOND THE INSIDE WALL OF THE POOL. UNDER EXISTING CONDITIONS THIS REQUIREMENT MAY BE LESS THAN AS STATED ABOVE. ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS, INDICATED OR REPRESENTED BY THIS DRAWING, ARE OWNED BY AND THE PROPERTY OF THIS OFFICE AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN; CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS, SHALL BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF TWENTY FIRST CENTURY ENGINEERING. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECED- ENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE §,JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. REVISIONS • • MIN ■■■E MEIN ��••U�rl� A PREPARED FOR: DOLPH IN POOLS EXISTING 4' CBS WALL CONC. PAD FOR EQUIF�v LNT - S`iZE TO BE DETERMINED IN FIELD - SEE PAD DETAIL FOR THICKNESS AND REINFORCEMENT PAGE 1 NOTE: ALL CONDUCTOR CLEARANCES SHALL COMPLY WITH N.E.C. 680,8 FOR OVERHEAD, AND N,E,C. 680.10 FOR UNDERGROUND, REFERENCE N,E,C. 2005 7' ID SPA RAISED 12', 6 JETS, 8' M /D'S ALSO UTILIZED AS SPILLWAY RETURNS, 9' WALL, BLOWER, 30' SPILLWAY, 18' BENCH & 100 W LIGHT - SEE DETAIL PAGE 2 2" S/O AIR LINE 2" 5/0 THERAPY LINE 2" SKIMMER LINE 2" VAC LINE 2 1/2" SPA M/D LINE 2" POOL RETURN LINE 2" THERAPY LINE 2" BLOWER LINE 2" SPA RETURN LINE I 1/2" VENT LINE NOT TO EXCEED 54' VERIFY IN FIELD 2" POOL M/D LINE z CZ U W V) A 0 W U ao' U W V) o_ z J CONC. PAD FOR EQUIPMENT - SIZE TO BE DETERMINED IN FIELD - SEE PAD DETAIL FOR THICKNESS AND REINFORCEMENT PAGE I NOTE: ALL CONDUCTOR CLEARANCES SHALL COMPLY WITH N,E,C. 680.8 FOR OVERHEAD, AND N,E,C. 680.10 FOR UNDERGROUND, REFERENCE N.E.C. 2005 z W U W V) Pi 0 W U 0_ <I CZ 0 W rn n. z J 4' -9" 25'-4" 20' -7" 4' -9" 20' -7" O d EXISTING CONC,,, WALK GUEST HOUSE 24' -9" GUEST HOUSE EXISTING C ONC. W415 _ LED COLOR LIGHT 22'-4" 18" x 4' SWIMOUT W/ 2 THERAPY JETS SEE DETAIL PAGE 2 PAVER DECK 3 STEPS W/ TILE EDGE - SEE DETAIL PAGE 2 POOL TYPE "0" NON DIVING NOTE: TOP OF POOL ELEVATION IS MIN, 6' LOWER THAN F,F,E, OF HOUSE NOTE: TOP OF POOL ELEVATI ❑N IS MIN, 6' LOWER THAN F,F,E, OF HOUSE RUDNICK RESIDENCE 544 N.E. 93rd STREET MIAMI SHORES, FLORIDA RUDNICK RESIDENCE 544 N.E. 93rd STREET::: MIAMI SHORES, FLORIDA-; DOOR $ WINDOW ALARMS PER SECTION 424.2.1 7. 1 .9 POOL PL, PER SECTION 424.2. 17. I .9 POOL DIIvME \SIO \S SCALE : 1/8" 1' -O" SCALE : 1/8" 1' -0" NORTH ARROW NORTH ARROW VENT PIPE MAXIMUM LENGTH COPING 12" 12" I2" 2 #3's CONT. #3's C4 10" OCEW / #3 @ 6" O.C.E.W. (SEE TYPICAL WALL SECTION) POOL STEP DETAIL N.T.S. (/.61" LIQUID TIGHT PVC CONDUIT 1/2" LIQUID TIGHT PVC CONDUIT 1. THIS SAFETY VACUUM RELIEF SYSTEM IS A N❑N- MECHANICAL VENT SYSTEM THAT WILL LIMIT THE TRANSMISSI ❑N OF SUCTION AT THE OUTLET TO A MAXIMUM OF 4.5 INCHES OF MERCURY. 2, THIS SYSTEM IS A BACKUP TO PR ❑VIDE SUCTI ❑N RELIEF SHOULD ENTRAPMENT OCCUR. a POOL AND SPA SUCTI ❑N INLETS SHALL BE PROVIDED WITH A COVER THAT COMPLIES WITH ANSI /ASME A112,19,8M PUMP AVG. VENT MAX, SIZES FLOW SIZES LENGTH 1 HP 60 GPM 1-1/2' 32 FT 1,5 HP 75 GPM 1 -1/2' 41 FT 2 HP 100 GPM 1 -1/2' 54 FT 2,5 HP 135 GPM 1-1/2' 73 FT IMPORTANT NOTE: NO DIVING BOARD AND NO DIVING IS ALLOWED ON ANY POOL LESS THAN 8' -0" DEEP AND SPECIFICALLY DESIGNED FOR DIVING. THIS POOL IS NOT DESIGNED FOR DIVING. 35' -0" Pools & Spas with heaters: Per FBC612.1.ABC.2.3.2, the pool and spa shall be provided with a cover or other means to reduce heat loss. 5' -0' 24' -0' HEATER 4, THE VELOCITY ON THE SUCTI ❑N SIDE OF THE CIRCULATI ❑N SYSTEM SHALL NOT EXCEED SIX (6) FPS. 5. CHECK VALVES CANNOT BE INSTALLED ON THE SUCTION SYSTEM, 6. THIS SYSTEM SHALL BE INSTALLED AND TESTED BY A QUALIFIED, LICENSED SWIMMING POOL PROFESSIONAL. 7. THE VENT LINE LENGTH MUST NOT EXCEED THE TOTAL LENGTH OF THE MAIN DRAIN LINE. 8. VENT OPENING MUST BE COVERED WITH WIRE MESH SCREEN TO PREVENT INSECTS, DEBRIS COLLECTI ❑N AND BACTERIA. 9. LABEL VENT: POOL SAFETY DEVICE- D❑ NOT HANDLE BASED ON FOLL ❑WING EQUATI ❑N ONE HP PUMP FLOW RATE 60GPM @60'TDH 60GPM / (60X7,48) = 0,13369 CUBIC FEET PER SECOND. FLOW X 3 SECONDS (CODE REQUIRED) = MAXIMUM SIZE OF OPENING. 1:7 MAXIMUM SLOPE DESIGN SLOPE 7' 111' 0.13369 X 3 = 0,4011 CUBIC FEET AREA OF 1 -1/2' VENT PIPE = .01227 SQ FEET THE ALLOWABLE LENGTH = 0,4011 / .01227 = 32 FEET THEREFORE, FOR A 1HP PUMP AND 1 -1/2' VENT LINE, THE MAXIMUM LENGTH OF PIPE IS 32 FEET 11° SLOPE (TYP) MAX. (HEATER) (4) 2-1/2" ANGLE BRACKETS WITH (4) I -3/4" X 1/4" TAP CON AND (4) 1/2" SELF TAPPING SHEET METAL SCREWS. POOL SECTI ❑N {2 #Aer -11,- 7 I LA = .5 N.T.S. 43 e r,..t1 , *v =CO" 30" SPILLWAY POOL COPING AUX. BEAM 4 COPING ,-TILE BACK OF AUX POOL SPST 12 V T/F G 1) LED POOL LIGHT 2 - #3 CONT DECK PRECAST COPING SPST AP 1) 100 W SPA LIGHT . DECK W/ ALL ORGANIC MATERIALS REMOVED FROM UNDER DECK AREA WATERPROOF GFCI, MIN. 10' AND MAX. 20' TO WATER 12- 12 -12, THHN SPA BLOWER, 12- 12 -12, THHN SLOPE \--(1) 90° BEND WATER LEVEL - 9" WALL $ FLOOR W / #3 @ O/C EACH WAY OR WI 2 MATS OF #3 @ 12" O/C EACH WAY. SEE TYPICAL WALL -; SECTION FOR DETAILS STEP OPTIONAL 18" HIGH BENCH 1 1/2' VENT LINE — PANEL CLEAN FILL AUTOPILOT CHLORINE GENERATOR 12 -12 -12 THHN POOL RECIRC PUMP, 12- 12 -12, THHN POOL HEATER, 8 -8 -8 THHN MIN VERTICAL 2' -3" SHALLOW END 3' -O" DEEP END 2 -8" AUX. POOL DRAIN SECURED W/ SCREWS. MAIN DRAIN MAIN DRAIN NOTE: 1. BOND ALL BOXES, RAILS, LIGHTS, STEEL & DECK, ECT. W/ #8 THHN WIRE IN POOL AREA PER NATIONAL ELECTRIC CODE 680. 2. POOL LOCATION MUST COMPLY WITH NATIONAL ELECTRIC CODE. TIME CLOCK SPST WP WATERPROOF, SINGLE POLE SINGLE THROW TOGGLE SWITCH 4 APPROVi P /. / . / STEELTEX FORM. KRAFTBOARD OR EQUIV. 2" COVER CENTER 6" WALL W/ #3 @ t► 5.C.E.W. AUX. POOL DETAIL • • WELL COMPACTED FILL 2 / 1 2" TO PUMP N.T.S. w 7 w C1) � SEE NOTE BELOW WATERPROOF MANUAL STARTER SWITCH DISC. MANUAL DISCONNECT WITHIN SIGHT OF POOL HEATER 8" FLOOR W/ #3 @ 0" 0.C.E.W. TYPICAL WALL SECTION SAFETY VACUUM RELEASE SYSTEM (SVRS) N.T.S. TRANSFORMER N.T.S. 'i{),p�S { Y ,s f Lam_ AUG 1 3 2007 bL_A o6ac- PERMIT OtepRil -)i7� MIAMI SHORES VILLAGE APPROVED BY DATE r /x/9 ' ZONING . ' 1 STRUCTURAL 70 t4 VT l 4, ELECTRICAL r_ c l e" PLUMBING _.. igdy MECHANICAL a 611 BLDG. 6 Zetri SUBJECT TO COMPL Na W$T1N1 AiLL FEDERAL STATE AND COUNTY RULES AND EtE'GULATtONS dil cell' s7/-e• G'/G e Pry Pi a- fir( �, r, 0 0 000 0 1