BPP-07-1706 (2)NL TFL
TUP LIF POOL ELEVATION IS MIN.
6" LOWER THAN F.F.E. OF HOUSE
PUMP FRAME,
FILTER TANK MOUNT
7-1 3/4" x 3/16" TAP CON.
",,■- REINFORCED CONC. SLAB
-II11 =1111
11111 1111
I I1= 1111 = 11111 = 11111111
FILTER
z din"
id
r
EXISTING ELECT.
PANEL/ METER
n
's —°
MAINTAIN MIN.
SETBACKS
PER CODE
-
LANDSCAPE SCREEN
PER CODE
-
1
CONC. PAD FOR EQUIPMENT - SIZE TO BE
DETERMINED IN FIELD - SEE PAD DETAIL FOR
THICKNESS AND REINFORCEMENT PAGE I
4/Se v�
FOR POOL LOCATIO\ 0
S
IF PLA\
NORTH ARROW
SCALE : 1"= 20'
\LY
RUDNICK RESIDENCE
544 N.E. 93rd STREET
MIAMI SHORES, FLORIDA
6' X 6" X 1.4" W.W.F.
z
f
EQUIPMENT PAD SIZE TO
BE DETERMINED IN FIELD
EQUIPMENT PAD DETAIL
N.T.S.
BARRIER NOTE:
OUTDOOR SWIMMING POOLS AND SPAS SHALL BE PROVIDED
WITH A PERMANENT BARRIER THAT SHALL BE INSTALLED,
INSPECTED & APPROVED PRI ❑R TO PLASTERING OR FILLING
WITH WATER. SUCH PERMANENT BARRIER SHALL BE IN
ACCORDANCE WITH SECTI ❑N F.B.C. LATEST EDITION,.
SPECIAL PROVISI ❑NS:
1. ALL SWIMMING POOLS, SPAS AND HOT TUB AREAS SHALL BE
PROVIDED WITH A PERMANENT SAFETY WARNING SIGN IN READILY
VISIBLE L ❑CATI ❑N FROM THE POOL AREA
(APPENDIX F ANSI - NSPI -5 -95)
2, EACH SAFETY WARNING SIGN SHALL WARN AGAINST SHALLOW
WATER DIVING, PREVENTI ❑N OF DROWNING & INCLUDE THE
FOLLOWING STATEMENT: "THERE IS NO SUBSTITUTI ❑N FOR ADULT
SUPERVISION OF SMALL CHILDREN. IT IS STRONGLY
RECOMMENDED THAT AT LEAST ONE ADULT RENDERING CHILD
SUPERVISI ❑N BE TRAINED IN ARTIFICIAL RESPRATI ❑N AND/OR
CARDI❑PULM ❑NARY RESUSCITATION (CPR)"
HYDRAULIC UPLIFT C[1M4FUTA T IDNS
FLOOD CREST ELV. FOR AREA = 8,00'
TOP OF POOL ELV. = 10.15'
BOTTOM OF POOL ELV. = 4.15'
HYDRAULIC HEAD = 3.85'
ALLOWANCE HYDROSTATIC VALVE = -2.0'
NET HYDRAULIC HEAD = 1.85'
MSL
MSL
MSL
USE MIN, 8' THICK CONCRETE FLOOR SLAB
LEGAL DESCRIPTIDN
LOT: 4 & 5 & 20' OF WEST SIDE OF LOT 3
BLK: 57
SUBDIVISI ❑N: MIAMI SHORES SEC. NO, 2
PLAT BOOK: 10 PG:37
PUBLIC RECORD OF MIAMI -DADE COUNTY, FL.
(2) 8" ANTI VORTX SPA MAIN
DRAINS ALSO UTILIZED AS
SPILLWAY RETURNS
MIN. 3' APART
ALARM NOTE:
ALL WALLS THROUGH WHICH A DOOR PROVIDES ACCESS TO THE POOL SHALL BE EQUIPPED WITH AN
ALARM AUDIBLE WARNING WHEN THE DOOR OR ITS SCREEN IS BEING OPENED. THE ALARM SHALL SOUND
CONTINUOUSLY FOR A MIN. 30 SECONDS AFTER THE DOOR IS OPENED AND BE CAPABLE OF EMITTING A
SOUND OF SUFFICIENT VOLUME TO BE HEARD WITHIN THE DWELLING, THE ALARM SHALL BE EQUIPPED WITH
A MANUAL MEANS TO TEMPORARLY DEACTIVATE THE ALARM FOR A SINGLE OPENING. THE DEACTIVATION
SWITCH SHALL BE LOCATED AT LEAST 54" ABOVE THE THRESHOLD OF THE THE DOOR,
NOTE: LAYOUT OF POOL AND HOUSE
DRAWN BY SUBMITTAL OF SURVEY FROM
THE POOL CONTRACTOR. TWENTY FIRST
CENTURY ENGINEERING IS NOT RESPONSIBLE
FOR ANY DISCREPANCIES DUE TO ANY
ILLEGIBLE DIMENSIONS OR UTILITIES NOT
SHOWN ON SURVEY.
CONSTRUCTION NOTES
(1) POOL LOCATION MUST COMPLY WITH N.E.C. (ARTICLE CO.) (58
(2) POOL PERIMETER BARRIER - EXISTING FENCE - ALARM
1 HP
MANUF T.B.D.
MODEL# T.B.D.
SPA PLUMBING ISOMETRIC
N.T.S.
NOTE:
ALL CONDUCTOR CLEARANCES SHALL
COMPLY WITH N.E.C. 680.8 FOR
OVERHEAD. AND N.E.C. 680.10 FOR
UNDERGROUND. REFERENCE N.E.C. 2005
POOL PUMP, FILTER
AND HEATER ANCHOR
POINTS (TYP)
I
L .7
0 rPUMP
l
NOTES: ANCHOR BOLTS THROUGH BASE (1 -3/4"
x 3/16" TAP CONS) FOR POOL PUMP & FILTER
HEATER SHOWN AS OPTIONAL (4) 1 -1/2" ANGLE
BRACKETS (GAS HEATER) (4) 2 -1/2" ANGLE
BRACKETS (HEAT PUMP) WITH (4) 1 -3/4" X 3/16"
WITH (4) 1 3/4" x 3/16" TAP CON AND (4) 1/2"
SELF TAPPING SHEET METAL SCREWS.
�-'
POOL EQUIPMENT ANCH ❑RING N.T.S.
'4t1r °f 114 r,, e 4r.Qesti /0-91
kr t -141»e 5 peI;),
PLUG OR
HYDROSTATIC
VALVE i-112'
ANTI VORTEX GRATE
TO BE FASTENED
WITH SCREWS
WELL POINT
KOCK BED
WELL POINT DETAIL
N.T.S.
GROUND LEVEL, POOL DECK OK
MAX. POOL WATER. LEVL,�
WHICHEVER I5 GREATER
1-1/2" PVC TEE TO
MATCH VENT LINE SIZE
WINDOW SCREEN
TYP. 2 PLACES)
PVC SLEEVE
PRESSED IN PLACE
THE ATMOSPHERIC VENT TEE SHALL BE LOCATED NOT
LESS THAN 8 ", MEASURED FROM THE BOTTOM OF THE
STRAIGHT LEG OF THE TEE, ABOVE THE GROUND LEVEL,
POOL DECK, OR MAXIMUM POOL WATER LEVEL,
WHICHEVER PROVIDES THE GREATEST ELEVATION.
ATMOSPHERIC VENT DETAIL
INLINE
SALT - C/L
GENERATOR
N.T.S.
POOL SIZE:
POOL PERIMETER:
VOLUME: (GALLONS)
POOL EQUIPMENT
SPECIFICATIONS
22
' X 34'
.8
1' -9" LF
18,311
POOL PUMP:
POOL FILTER: 1 C-1750 1
POOL INLETS:
SKIMMER:
POOL LIGHT:
POOL HEATER TYPE:
POOL HEATER SIZE:
CLEANING LINE:
CLEANING SYSTEM:
CHLORINATOR:
2 11P HAYWARD
I ) COLOR LED
HEAT PUMP
1 13 K
YES
N/A
SALT — C/L GEN.
COPING:
TILE:
SWIMOUT:
LADDER:
HANDRAIL:
AUX. POOL
SPILLWAY SIZE:
LIONS HEAD:
SPRITZER /SPRAY HEAD:
THERAPY JETS:
POOL
POOL DEPTH:. 1 ,Y 3' TO 6'
POOL AREA SQ. FT.:
TURNOVER RATE13o5 HR @ 10o GPMI
AUXILLIARY POOLQU1FMENT
544 SF
AUX. POOL PERIMETERc, -2? L—
AUXILLIARY PUMP:
AUX. POOL JETS:
AUX. POOL LIGHT:
AUX. HEATER TYPE:
AUX. HEATER SIZE:
RAISED:
STEP(S):
BLOWER:
TURNOVER RATE:
FINISH ITEMS
HANDHOLDS:
INTERIOR FINISH:
DECK S.F.:
CAPPING S.F.:
DECK TYPE:
TUMBLED MARBLE
6"
YES
N/A
N/A
WATER FEATURES
30"
N/A
N/A
2) IN SWIMOUT
FIBER OPTIC SPOT(S):
PERIMETER LIGHTS:
POOL ENCLOSURE:
FOOTERS L.F.:
DECO -O- DRAIN:
PILING POOL:
N/A
N/A
FOUNTAIN FEATURE:
SHEER DESCENT:
FEATURE PUMP:
OTHER:
LIGHT FEATURES
REMOTE :
LIGHT SWITCH:
NO
YES
AS POOL
6
1)IOOW
AS POOL
AS POOL
12"
N/A
1 HP
4 MIN. @ 40 GPM
YES
GEM COAT
831 5F
200 5F
L
PAVER
N/A 1
N/A
N/A
N/A
N/A
COLOR WHEEL:
# OF COLORS:
ADDITIONAL FEATURES
ALARM/ EXISTING FENCE
N/A
N/A
N/A
GLASS BLOCK TYPE:
GLASS ROWS HT:
GLASS ROWS WDTH.
# OF GLASS BLOCKS.
NO
N/A
N/A
N/A
N/A
N/A
* DOES NOT INCLUDE 8' -8" COMMON POOL/ SPA WALL
UNION TYP.
OF 2
BALL VALVE
3 WAY JANDY VALVE
L- F
IVI
113K HEAT
PUMP
2 WAY JANDY W/ ACTUATOR
3 WAY JANDY W/ ACTUATOR
SWING CHECK VALVE
gill)I
COI
A2 H.P. PUMP W/ HAIR &
LINT STRAINER - 94
GPM TO 112 GPM
B2 H.P. BLOWER
4 LB CHECK
VALVE
2'
1
FILTER
1
POOL/ SPA DRAIN -T❑
BE RETAINED ON SITE
2 H P. BLOWER
(2) 8' MAIN DRAINS W/
ANTI VORTEX COVERS
MINIMUM 3' APART.
HANDHOLD DETAIL
N.T.S.
LOCATE @
WATERLINE
POOL PLUMBING ISOMETRIC
N.T.S.
PROVIDE A HAND HOLD NO
MORE THAN 9' ABOVE THE
NORMAL WATER LEVEL.
NOTE: CERAMIC TILE
HAND HOLD
MAX. SPACING
SHALL NOT
EXCEED 48"
SWING CHECK
VALVE
2' TO SPA FOR
SPILLWAY
2' T ❑
POOL RETURNS
2' TO THERAPY
JETS
SWING CHECK
VALVE
2 1/2" FROM SPA
MAIN DRAINS
2" FROM
POOL SKIMMER
I
2 1 /2" FROM
POOL
MAIN DRAINS
2' VAC LINE
o�— 1" VENT
ED
PIPING SCHEMATIC
N.T.S.
2" AIR LINE
TO SPA
GENERAL NOTES
CODE REQUIREMENTS - Private swimming pool and spas must comply with chapter' 424 & 24101.
Florida Building Code, 2006,
Mechanical Requirements! All piping, equipment and materials used in the plumbing system of'
swimming pools (Spas) that are built in place shall conform to the F loridri Code,
Plumbing. (424,2,3 & R4101.3), All piping materials shall be installed in strict ac_coPdance with
the installation standards. Compliance All a H1Ss)tu r equ' pm nt or applianc s entering into the construction of' swimro ngpoot (Spas) or
portions thereof shall be of a type complying with the code or of a type recommended
and approved by a nationally recognized testing agency or conforming to other
recognized standards acceptable to the administrative authority.
Engineering Design Design, Construction and workmanship shall be in conformity with ANSI /
NSPI 3,4,5, &6 2003, published by the National Spa and Pool Institute, or other accepted
engineering practices.
ENTRAPMENT Testing and Certification All pool and spa suction inlets shall be provided with
a cover that has been tested and accepted by a recognized testing facility and comply
with ANS /ASME A112.19.BM, "Suction Fittings for Use in Swimming Pools, Spas, Hot Tubs, and
Whirlpool Bathtub Appliances." Exception Surface Skimmers,
Safety Note: Do not use or operate pool or spa if the suction inlet fitting is missing,
broken, or loose.
Entrapment Avoidance If the suction inlet system, such as an automatic cleaning system, is
a vacuum cleaner system which has a single suction inlet, or multiple suction inlets which
can be isolated by valves, then each suction inlet shall protect against user entrapment
by either an approved antivortex cover, 12' X 12' grate or larger, or other approved
means per FBC 424.2.6.6.4 & R4101.6,6.4.
In addition, all pools and spas shall be required to have a backup system which shall
provide vacuum relief should grate covers be missing. Alternate vacuum relief devices
shalt include either:
1. Approved Vacuum Release System
2. Approved Vent Piping
3. Other Approved Devices or Means
Suction Inlet Per Pump! A minimum of' two suction inlets shall be provided for each pump in
the suction inlet system, separated by a minimum of' 3 feet or located on two different
planes} i.e., on the bottom and one on the vertical wall, or one each on two separate
vertical walls. These suction inlets shall be plumbed such that water is drawn through
them simultaneously through a common line to the pump, per FBC 424.2.6.6.4 & R4101.6.6.4.
Cleaner Fittings: Where provided, the vacuum or pressure cleaner fitting(s) shall be
located in an accessible position at least 6 inches and not greater than 12 inches below
the minimum operating water level or as an attachment to the skimmer(s). All clearner
suction inlets shall be protected by an approved, permanently installed, self - closing
flapper, per FBC 424,2,6,6,5 & R4101.6.6.5.
Valve: Valves shall be made of materials that are approved in the Florida Building
code, Plumbing. Valves located under concrete slabs shalt be set in a pit having a
least dimension of five pipe diameters, minimum 10 inches, fitted with a suitable cover,
per FBC 424,2,8,1 & R4101.81.
Waste Water Disposal! Direct or indirect connections cannot be made to existing facilities
without the prior approval of the administrative authority, per FBC 424,2,10 & R4101.10.
Tests: All pool piping shall be inspected and approved before cover or concealment. It
shall be tested and proved tight under a static water or air pressure test of not
less than 35 psi for 15 minutes. Per manufacture recommendations, no air test shall be
approved for PVC pipe and fittings, per FBC 424,2.12,1 & R4101.12,1.
Water Heating Equipment: Swimming pool water heating equipment shall conform to the design,
construction and installation requirements in accordance with accepted engineering
practices and shall bear the label of a recognized testing agency, and shall include a
consideration of combustion alr, venting and gas supply requirements for water heaters
Sec. 424.2,14.1 & R4101,14,1. It must contain a thermostatic or high - pressure control switch so
the pool water does not exceed 104 degrees F. Sec. 424.2.14.4 & R4101.14.4. Water heating
equipment shall be installed with flanges or union connections adjacent to the heater,
swimming pool water heating equipment shall have an internal check valve, per FBC 412.1.
Pool & spa covers: Pools amd spas with heaters shall be provided a cover or other
means to reduce heat toss, per FBC 13- 612.1.ABC,2.3.2.
Pool Enclosure: Residential Pools shall comply with FBC section 424.2.17.1 - 424.2.17.15 & R4101.17.1 - R4101,17,15
Ladders and Steps! All pools shall be provided with a ladder or steps In the shallow end
where the water exceeds 24 inches. Where water depth exceeds 5 feet, there shall be
ladders, stairs or underwa ter benches / swim outs in the deep end, per FBC 424.2.18 &
R4101.18.
Filters: The entire design of matched components shall have sufficient capacity to
provide a complete turnover of pool water In 12 hours or less per FBC 424.2.20 &
R4101.20,
Pool Fittings: Pool fittings shalt be of an approved type and design as to be
appropriate for the specific application, per FBC 424,2,2.1 & R4101,2.1 Per FBC 424,2.13.2
joints and connections and FBC plumbing Sec. 605,21, purple primer required on PVC
piping.
Skimmers: Skimmers shall be installed on the basis of one per 800 SF of' surface area or
fraction thereof, per FBC 4242,21.2 & R4101.21,4,
Hydrostatic Relief Device! In areas of' anticipated water table an approved
hydrostatic relief device shall be installed, per FBC 424.2.21,4 & R4101.21.4. Exception
is plastic liner pools,
Concrete / Steel: All floors & walls of pool to be pneumatically applied concrete with a
min 28 clay compressive strength of' 2500 psi. All reinforcing steel to conform to A615
grade 60.
Soil Statement: Based upon rational analysis, the soil in this area has a 2000 psf bearing
capacity after excavation and compaction. Should any muck, marl, or other organic soils
be discovered on excavation, they should be removed in their entirety. This pool requires'
2000 psf bearing capacity.
Pool Staking: This design engineer assumes no responsibility for pool construction in
easements or required setback areas. Plot plans not prepared from legal surveys of
the existing tot and residence are so indicated. The pool contractor shall verify all
dimensions in the field and establish lot lines. The pool contractor shall establish locations
of all utilities at the site. Min. clearance dimensions shall be held as required by the local
regulatory agency. In general, hold a distance of 10 feet from overhead electric lines to
open pool water,
Existing Structures: The pool contractor shall always take all precautions to protect
existing structures from failure by sheeting and /or shoring or other methods, the
design engineer accepts no responsibility for the safety of existing structures.
Backfill: The contractor shall backfill the pool shell with caution. The plumbing shall not
be disturbed. Backfill shall be accomplished with clean construction grade fill, free of
organic material and shall be placed in 12' lifts, each lift shall be compacted to 95% per
ASTM D -1557,
Warning: To empty pool after construction, for repairs or any other reason, the
hydrostatic uplift pressures beneath the pool must be eliminated to prevent the pool from
floating upward. The owner must consult a pool contractor or pool repair contractor'
experienced in eliminating uplift pressures.
Diving! No diving board and no diving is allowed on any pool less than 8'0" deep and
specifically designed for diving. This pool is not designed for diving unless specifically
stated on the site plan.
Gas Piping Gas piping shall comply with the Florida Building Code, Fuel Gas Sec. 424.2.15 &
R4101.15
Electrical! Electrical wiring and equipment shall comply with the 2005 National Electrical
Code SEC 680. IF REQUIRED BY THE LOCAL MUNICIPALITY THE POOL/ SPA DECK SHALL BE BONDED
PER 2005 NATIONAL ELECTRIC CODE SECTI ❑N 680
EQUIPOTENTIAL BONDING GRID SINGLE WIRE:
PER THE BOARD OF RULES AND APPEALS MEETING ON MAY 10, 2007 AN ALTERNATIVE
METHOD FOR SWIMMING POOLS AND SPA EQUIPOTENTIAL BONDING GRID OF POOLS AND SPAS
WITH LIGHTS OF 15 VOLTS OR LESS OR NO LIGHTS MAY USE A SINGLE WIRE GRID (#8 AWG)
WHEN INSTALLED AS FOLLOWS:
THIS INCLUDES UNPAVED SURFACE AS WELL AS POURED SURFACES AND OTHER TYPES
OF PAVING.
1) ATTACHED TO THE POOL REINFORCING STEEL OR COPPER CONDUCTOR GRID
(SINGLE #8 AWG WIRE) AND
2) BURIED TO A MIN. DEPTH OF 4" NOT TO EXCEED 6" BELOW GRADE
3) CONNECTED BY A MIN. OF FOUR POINTS UNIFORMLY SPACED AROUND THE
PERIMETER OF THE SWIMMING POOL AND OR SPA AND
4) CONNECTED TO AN EQUIPOTENTIAL GRID
COPPER BARE CONDUCTOR NOT SMALLER THAN
5) CONNECTION SHALL BE MADE EXOTHERMIC WELDING OR BY LISTED PRESSURE
CONNECTORS OR CLAMPS THAT ARE LABELED AS BEING SUITABLE FOR THE PURPOSE
AND ARE OF STAINLESS STEEL, BRASS, COPPER, OR COPPER ALLOY AND
6) THE EQUIPOTENTIAL BONDING GRID
SHALL EXTEND UNDER PAVED AND UNPAVED WALKING SURFACERS FOR ONE METER
(THREE FEET) HORIZONTALLY BEYOND THE INSIDE WALL OF THE POOL. UNDER EXISTING
CONDITIONS THIS REQUIREMENT MAY BE LESS THAN AS STATED ABOVE.
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS, INDICATED
OR REPRESENTED BY THIS DRAWING, ARE OWNED BY AND THE
PROPERTY OF THIS OFFICE AND WERE CREATED, EVOLVED AND
DEVELOPED FOR USE ON AND IN; CONNECTION WITH THE SPECIFIED
PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR
PLANS, SHALL BE USED BY OR DISCLOSED TO ANY PERSON,
FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT
THE WRITTEN PERMISSION OF TWENTY FIRST CENTURY ENGINEERING.
WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECED-
ENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY
AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS
ON THE §,JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY
VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN
BY THESE DRAWINGS.
REVISIONS
•
•
MIN
■■■E
MEIN
��••U�rl� A
PREPARED FOR:
DOLPH IN
POOLS
EXISTING 4' CBS WALL
CONC. PAD FOR EQUIF�v LNT - S`iZE TO BE
DETERMINED IN FIELD - SEE PAD DETAIL FOR
THICKNESS AND REINFORCEMENT PAGE 1
NOTE:
ALL CONDUCTOR CLEARANCES SHALL
COMPLY WITH N.E.C. 680,8 FOR
OVERHEAD, AND N,E,C. 680.10 FOR
UNDERGROUND, REFERENCE N,E,C. 2005
7' ID SPA RAISED 12', 6 JETS, 8'
M /D'S ALSO UTILIZED AS SPILLWAY
RETURNS, 9' WALL, BLOWER, 30'
SPILLWAY, 18' BENCH & 100 W
LIGHT - SEE DETAIL PAGE 2
2" S/O AIR LINE
2" 5/0 THERAPY LINE
2" SKIMMER LINE
2" VAC LINE
2 1/2" SPA M/D LINE
2" POOL RETURN LINE
2" THERAPY LINE
2" BLOWER LINE
2" SPA RETURN LINE
I 1/2" VENT LINE NOT TO
EXCEED 54' VERIFY IN FIELD
2" POOL M/D LINE
z
CZ
U W
V) A
0
W U
ao'
U W
V) o_
z
J
CONC. PAD FOR EQUIPMENT - SIZE TO BE
DETERMINED IN FIELD - SEE PAD DETAIL FOR
THICKNESS AND REINFORCEMENT PAGE I
NOTE:
ALL CONDUCTOR CLEARANCES SHALL
COMPLY WITH N,E,C. 680.8 FOR
OVERHEAD, AND N,E,C. 680.10 FOR
UNDERGROUND, REFERENCE N.E.C. 2005
z
W
U W
V) Pi
0
W U
0_
<I CZ
0 W
rn n.
z
J
4' -9"
25'-4"
20' -7"
4' -9"
20' -7"
O d
EXISTING CONC,,, WALK
GUEST HOUSE
24' -9"
GUEST HOUSE
EXISTING C ONC. W415
_
LED COLOR LIGHT
22'-4"
18" x 4' SWIMOUT
W/ 2 THERAPY JETS
SEE DETAIL PAGE 2
PAVER DECK
3 STEPS W/ TILE
EDGE - SEE
DETAIL PAGE 2
POOL TYPE "0"
NON DIVING
NOTE:
TOP OF POOL ELEVATION IS MIN,
6' LOWER THAN F,F,E, OF HOUSE
NOTE:
TOP OF POOL ELEVATI ❑N IS MIN,
6' LOWER THAN F,F,E, OF HOUSE
RUDNICK RESIDENCE
544 N.E. 93rd STREET
MIAMI SHORES, FLORIDA
RUDNICK RESIDENCE
544 N.E. 93rd STREET:::
MIAMI SHORES, FLORIDA-;
DOOR $ WINDOW ALARMS
PER SECTION 424.2.1 7. 1 .9
POOL PL,
PER SECTION 424.2. 17. I .9
POOL DIIvME \SIO \S
SCALE : 1/8" 1' -O"
SCALE : 1/8" 1' -0"
NORTH ARROW
NORTH ARROW
VENT PIPE MAXIMUM LENGTH
COPING
12" 12" I2"
2 #3's CONT.
#3's C4 10" OCEW
/ #3 @ 6" O.C.E.W.
(SEE TYPICAL WALL SECTION)
POOL STEP DETAIL
N.T.S.
(/.61" LIQUID TIGHT PVC CONDUIT
1/2" LIQUID TIGHT PVC CONDUIT
1. THIS SAFETY VACUUM RELIEF SYSTEM IS A
N❑N- MECHANICAL VENT SYSTEM THAT WILL LIMIT THE
TRANSMISSI ❑N OF SUCTION AT THE OUTLET TO A
MAXIMUM OF 4.5 INCHES OF MERCURY.
2, THIS SYSTEM IS A BACKUP TO PR ❑VIDE SUCTI ❑N
RELIEF SHOULD ENTRAPMENT OCCUR.
a POOL AND SPA SUCTI ❑N INLETS SHALL BE
PROVIDED WITH A COVER THAT COMPLIES WITH
ANSI /ASME A112,19,8M
PUMP AVG. VENT MAX,
SIZES FLOW SIZES LENGTH
1 HP 60 GPM 1-1/2' 32 FT
1,5 HP 75 GPM 1 -1/2' 41 FT
2 HP 100 GPM 1 -1/2' 54 FT
2,5 HP 135 GPM 1-1/2' 73 FT
IMPORTANT NOTE:
NO DIVING BOARD AND NO DIVING IS ALLOWED ON ANY POOL
LESS THAN 8' -0" DEEP AND SPECIFICALLY DESIGNED FOR
DIVING. THIS POOL IS NOT DESIGNED FOR DIVING.
35' -0"
Pools & Spas with heaters:
Per FBC612.1.ABC.2.3.2, the pool and
spa shall be provided with a cover or
other means to reduce heat loss.
5' -0' 24' -0'
HEATER
4, THE VELOCITY ON THE SUCTI ❑N SIDE OF THE
CIRCULATI ❑N SYSTEM SHALL NOT EXCEED SIX (6) FPS.
5. CHECK VALVES CANNOT BE INSTALLED ON THE
SUCTION SYSTEM,
6. THIS SYSTEM SHALL BE INSTALLED AND TESTED BY
A QUALIFIED, LICENSED SWIMMING POOL PROFESSIONAL.
7. THE VENT LINE LENGTH MUST NOT EXCEED THE
TOTAL LENGTH OF THE MAIN DRAIN LINE.
8. VENT OPENING MUST BE COVERED WITH WIRE MESH
SCREEN TO PREVENT INSECTS, DEBRIS COLLECTI ❑N AND
BACTERIA.
9. LABEL VENT: POOL SAFETY DEVICE- D❑ NOT
HANDLE
BASED ON FOLL ❑WING EQUATI ❑N
ONE HP PUMP FLOW RATE 60GPM @60'TDH
60GPM / (60X7,48) = 0,13369 CUBIC FEET
PER SECOND.
FLOW X 3 SECONDS (CODE REQUIRED) =
MAXIMUM SIZE OF OPENING.
1:7 MAXIMUM SLOPE
DESIGN SLOPE
7'
111'
0.13369 X 3 = 0,4011 CUBIC FEET
AREA OF 1 -1/2' VENT PIPE = .01227 SQ FEET
THE ALLOWABLE LENGTH = 0,4011 / .01227
= 32 FEET
THEREFORE, FOR A 1HP PUMP AND 1 -1/2' VENT
LINE, THE MAXIMUM LENGTH OF PIPE IS
32 FEET
11° SLOPE
(TYP) MAX.
(HEATER) (4) 2-1/2" ANGLE BRACKETS WITH (4) I -3/4" X
1/4" TAP CON AND (4) 1/2" SELF TAPPING SHEET METAL
SCREWS.
POOL SECTI ❑N
{2 #Aer -11,- 7 I LA = .5 N.T.S.
43 e r,..t1 , *v =CO"
30" SPILLWAY
POOL
COPING
AUX. BEAM
4 COPING ,-TILE
BACK
OF AUX POOL
SPST
12 V
T/F
G 1) LED POOL LIGHT
2 - #3 CONT
DECK
PRECAST
COPING
SPST
AP
1) 100 W SPA LIGHT
. DECK W/ ALL
ORGANIC MATERIALS
REMOVED FROM
UNDER DECK AREA
WATERPROOF GFCI, MIN. 10' AND MAX. 20' TO WATER
12- 12 -12, THHN
SPA BLOWER, 12- 12 -12, THHN
SLOPE
\--(1) 90° BEND
WATER LEVEL -
9" WALL $ FLOOR W / #3 @
O/C EACH WAY OR WI
2 MATS OF #3 @ 12"
O/C EACH WAY.
SEE TYPICAL WALL -;
SECTION FOR DETAILS
STEP
OPTIONAL
18" HIGH
BENCH
1 1/2' VENT LINE —
PANEL
CLEAN FILL
AUTOPILOT CHLORINE GENERATOR 12 -12 -12 THHN
POOL RECIRC PUMP, 12- 12 -12, THHN
POOL HEATER, 8 -8 -8 THHN
MIN VERTICAL 2' -3"
SHALLOW END 3' -O"
DEEP END
2 -8" AUX. POOL DRAIN
SECURED W/ SCREWS.
MAIN DRAIN
MAIN DRAIN
NOTE:
1. BOND ALL BOXES, RAILS,
LIGHTS, STEEL & DECK, ECT. W/
#8 THHN WIRE IN POOL AREA PER
NATIONAL ELECTRIC CODE 680.
2. POOL LOCATION MUST COMPLY
WITH NATIONAL ELECTRIC CODE.
TIME CLOCK
SPST
WP
WATERPROOF, SINGLE
POLE SINGLE THROW
TOGGLE SWITCH
4 APPROVi P
/. /
. / STEELTEX FORM.
KRAFTBOARD OR EQUIV.
2" COVER CENTER
6" WALL W/ #3 @
t►
5.C.E.W.
AUX. POOL DETAIL
•
• WELL COMPACTED FILL
2 / 1 2" TO PUMP
N.T.S.
w
7
w
C1)
�
SEE NOTE BELOW
WATERPROOF
MANUAL STARTER
SWITCH
DISC. MANUAL DISCONNECT
WITHIN SIGHT OF POOL
HEATER
8" FLOOR W/ #3 @ 0" 0.C.E.W.
TYPICAL WALL SECTION
SAFETY VACUUM RELEASE SYSTEM (SVRS)
N.T.S.
TRANSFORMER
N.T.S.
'i{),p�S { Y ,s f Lam_
AUG 1 3 2007
bL_A o6ac-
PERMIT OtepRil -)i7�
MIAMI SHORES VILLAGE
APPROVED
BY
DATE
r /x/9 '
ZONING
. '
1
STRUCTURAL
70 t4
VT l 4,
ELECTRICAL
r_ c
l e"
PLUMBING
_..
igdy
MECHANICAL
a 611
BLDG.
6 Zetri
SUBJECT TO COMPL Na W$T1N1 AiLL FEDERAL
STATE AND COUNTY RULES AND EtE'GULATtONS
dil cell' s7/-e• G'/G e
Pry Pi a-
fir( �,
r, 0 0 000 0
1