BP-06-59GENERAL NOi]ST AND CONDITIONS 1). ALL FLOR AND WALLS OF P00I. TO BE PNEUMATICALLY APPLIED CONC. WITH A MIN. 28 DAYS COMPRESSIVE STRENGTH OF 3000 P.S.I. 2). ALL REINF. STEEL TO CONFORM TO A.S.T.M. A615 GRADE 60. 18). TEMPERATURE OF SPA WATER SHALL BE SET SO THAT MAXIMUM WATER TEMPERATURE DOES NOT EXCEED 102 DEGREES FAHRENHEIT. 19). UPON VISUAL INSPECTION SITE SOIL REVEALS A COMBINATION OF UNDISTURBED SAND AND LIMEROCK. A BEARING VALUE OF 2000 PSF HAS BEEN UTILIZED FOR DESIGN PURPOSES. 3). ALL POOL PIPING TO BE SCHEDULE 40 PVC NON THREADED NSF PIPE 20) WITH SOLVENT WELD JOINTS. 4). IN ALL CASES, THE POOL CONTRACTOR SHALL TAKE ALL PRECAUTIONS 21) TO PROTECT EXISTING STRUCTURES FROM FAILURE BY SHEATHING AND/ OR SHORING, OR OTHER METHODS AS REQUIRED. THE DESIGN ENGINEER ACCEPTS NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURES. 5). THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENT OR REQUIRED SETBACK AREAS. 22) PLOT PLANS NOT PREPARED FROM LEGAL SURVEYS OF THE EXISTING LOT AND RESIDENCE ARE SO INDICATED. POOL CONTRACTOR SHALL 23) VERIFY ALL DIMENSIONS IN THE FIELD AND ESTABLISH LOT LINES. IF NECESSARY, POOL CONTRACTOR AND /OR OWNER SHALL VERIFY SHOWN AND ALL DIMEMSIONS PRIOR TO CONSTRUCTION. 6). CONTRACTOR SHALL ESTABLISH LOCATIONS OF UTILITIES AT THE SITE MINIMUM CLEARANCE DIMENSIONS SHALL BE HELD AND SHALL BE AS REQUIRED BY THE LOCAL REGULATORY AGENCY. IN GENERAL, HOLD A DISTANCE OF 10' FROM OVERHEAD ELECTRIC LINES TO POOL'S WATER EDGE. 7). ALL POOL ENCLOSURES SHALL CONFORM TO FLORIDA STATUTES 515.27 AND 515.29., AND F.B.C. HAPT 424.2.17.1 -10. 8). WHERE POOLS ABUT OR AR LACED NEARBY SEA WALL OR BULKHEADS, SPECIAL CARE S LL BE EMPLOYED. THE WALLS SHALL BE IN GOOD CONDITION, NOT RMITTING ANY SHIFTING OR REMOVAL, OR LOOSENING OF THE SUPPOR ING SOIL AWAY FROM THE POOL. IF THE WALLS DO NOT FULLY CO TAIN THE SOILS BEHIND THEM, THEY SHALL BE REPLACED OR REPAIRS CONTINUAL MAINTENANCE OF THE WALLS IS REQUIRED BY THE PROPS TY OWNER. WHEN EXCAVATING FOR THE POOL, THE SEA -WALL TIEBA KS SHALL NOT BE CUT. WHEN DEADMEN FALL WITHIN THE EXCAVA ON, NOTIFY THE ENGINEER IMMEDIATELY FOR FURTHER INSTRUC 4 ONS. 9). THE CONTRACTOR SHALL BACKFILL POOk SHELL WITH CAUTION. THE PLUMBING SHALL NOT BE DISTURBED. BA FILL SHALL BE PERFORMED WITH CLEAN SAND, FREE OF ORGANIC MAI RIALS AND SHALL BE PLACED IN 12 INCHES THICK LAYERS. EACH ER SHALL BE COMPACTED TO 90% OF THE SOILS MAXIMUM DENSITY BY TA PERING SOLIDLY. SOILS BELOW THE DECK SHALL BE PLACED IN SIMI ' R MANNER. 10). WHERE DECKS ARE INDICATED BY OTHERS, THE DEC r . ESIGN NOTES SHOWN ON THE TYPICAL SECTION DO NOT APPLY. DEC F, DESIGN SHALL BE BY OTHERS. . ALL TREADS SHALL HAVE SLIP - RESISTING SURFACES PER ANSI /NSPI -5- 2003.6.1.5 . ACCESS GATE REQUIREMENTS PER F.B.C. 424.2.17.1.8 AMENDED 06- 03 -03: GATES SHALL BE EQUIPPED WITH A SELF - LATCHING & LOCKING DEVICE, 54" ABOVE FINISH GRADE ELEVETION. THE DEVICE SHALL BE PLACED ON THE POOL SIDE OF THE GATE. GATES SHALL OPEN OUTWARD AWAY FROM POOL. THE GATE SHALL HAVE NO OPENINGS GREATER THAN 1/2" WITHIN 18" OF THE RELEASE MECHANISM. . THIS POOL HAS BEEN DESIGNED TO ALL APPLICABLE REQUIREMENTS OF THE FLORIDA BUILDING CODE, SECTION 424. ALL DETAILS SHOWN ON PAGE 3 OF 3 OF THIS PLAN ARE NOT TO SCAT F 11). DO NOT DRAIN POOL UNDER HIGH GROUND WATER OR S RM CONDITIONS. 12). WARNING! DO NOT EMPTY POOL AFTER CONSTRUCTION FO ` ' EPAIRS OR ANY OTHER REASON BEFORE CONSULTING WITH A POOL O POOL REPAIR CONTRACTOR. HYDROSTATIC UPLIFT PRESSURES MUS E ELIMINATED TO PREVENT POOL FROM FLOATING ABOVE GROU ` p. AND CAUSING DAMAGE TO THE STRUCTURAL INTEGRITY OF THE POO 13). THIS PLAN REMAINS THE PROPERTY OF THE DESIGN ENGINEERS. IT NOT TRANSFERABLE FROM ONE CONTRACTOR TO ANOTHER WITH THE WRITTEN PERMISSION OF THE DESIGN ENGINEERS. 14). ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE F.B.C., 2002 EDITION, AND ARTICLE 680 N.E.C., 2002 EDITION. ALL BOND WIRES SHALL BE PROTECTED WITH APPROVED MATERIAL. THE CONTRACTOR SHALL INSURE THAT AN ELECTRICAL BONDING INSPECTION IS CALLED FOR AN APPROVED PRIOR TO PLACEMENT OF CONCRETE OVER THE BOND WIRE CONNECTIONS. CONNECTIONS DIRECTLY FROM THE POOL LIGHT TO A TRANSFORMER BOX IS PROHIBITED. ALL METAL PARTS IN THE POOL AREA, IN ADDITION TO ALL METAL DOORS, WINDOWS, SCREENED ENCLOSURES, OR OTHERS ITEMS CONTAINING METAL WITHIN A DISTANCE OF 5 FEET FROM POOL WATER'S EDGE, SHALL ALSO BE GROUNDED. 15). POOL LIGHT TO BE GROUNDED TO COMMON BONDING GRID CONSISTING OF (1) #8 CONTINUOUS COPPER WIRE LOOPED AROUND POOL PERIMETER. LOOP SHALL BE GROUNDED TO PANEL VIA POOL WALL STEEL, DECK REINFORCING,AND PUMP MOTOR CASING. 16). FILTER BACKWASH SHALL COMPLY WITH THE FLORIDA BUILDING CODE, 2001 EDITION. 17). POOL WATER DISPOSAL TO BE IN ACCORDANCE WITH FLORIDA BUILDING CODE, 2001 EDITION. ■ MIAMI SFICR S d..•.LI ;E APPROVED BY DATE ZON.N Al Y STRLkIUR,.L ELECTR PLUMP'NG 1 BLDG. SUEJL:. i t t.; STATE 'FL; COUN i LiNiti.t ;'.I +, L. 6' EXIST CHAIN LINI(FENCE TO REMAIN 00 ° -o1 • OPE 6 EXIST. CHAIN I TK FENCE REMAIN EXIST. WOO .zCE TO REMAIN EXIST. OVERHEP POWER SERVICE Ev POOL DECK 12.06' EXIST. 200 A HOUSE PAT, EXIST. ELECTRIC ME I LR -11 JJr RESIDENCE L.F.F. ELEV. = 12.56' GARAGE L.F.F. ELEV. = 10.11` EXIST. WATEI ,' 0 EXIST. WATER METER SEE NO 100' -0° PROPERTY LINE POOL PLAN SCALE: 1"- 20' -0" EXISTING DRAIN FIELD 6 EXIST, CHAIN LINK FENCE TO REMAIN 1,11 ii copy POOL SPECIFICATIONk POOL SIZE: 15' -0" X 30' -0" POOL DEPTH: 3' X 5' POOL PERIMETER: 90' POOL SQ. FTG: 450 POOL GALLONS: 13,464 TURNOVER RATE: 3.0 HRS± POOL RETURN: 3 SKIMMER:1 POOL LIGHT: (1) SAM INTERIOR FINISH: GEM CHLORINATOR TYP: N/A WATERLINE TILE: 6" CAP TILE ON SWIMOUT: YES (2) DECK JETS VAC LINE: YES COPING TYPE: V.K. B/N DECK TYPE: V.K. PAVERS POOL ENCLOSURE: FENCE BY- OWNEV CHAINLINK FENCE BY- OTHERS PUMP SIZE: 1.5 HP FILTER SIZE: 160 CART POOL M.D'S: 2 YKA CONSULTING ENGINEERS, INC. 6500 WEST ROGERS CIRCLE ST. 8000 BOCA RATON, FLORIDA 33487 TEL. 561. 998.0805 YEKTA KAVASOGLU P.E. P.E. # 41310 CA# 06141 S1 # 0852 E -MAIL: YKACE @BELLSOUTH.NET 423 SHORES LLC LOT: 15 & 16 / BLOCK: 50 SUBDIVISION: MIAMI SHORES SECTION NO.2 423 N.E. 92nd STREET MIAMI SHORES, FL. 33138 DATE :.12 /12/05 ORDER: 554 A. YEKTA KAVASOGLU P.E. # 41310 YKA #: 05 -462 SALESMAN: STEVE S. VEDAT DEMIREL, PhD, P.E P.E. # 49522 DRAWN BY: LAN REVISIONS: SHEET 1 OF 3 ji. 2. LVAN KIRK & SONS, INC. 3. DATE: 12 /27/05 ll • GENERAL NOTES AND CONDITIOnS 1). ALL FLOR AND WALLS OF POOL TO BE PNEUMATICALLY APPLIED CONC. WITH A MIN. 28 DAYS COMPRESSIVE STRENGTH OF 3000 P.S.I. 2). ALL REINF. STEEL TO CONFORM TO A.S.T.M. A615 GRADE 60. 3). ALL POOL PIPING TO BE SCHEDULE 40 PVC NON THREADED NSF PIPE WITH SOLVENT WELD JOINTS. 4). IN ALL CASES, THE POOL CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO PROTECT EXISTING STRUCTURES FROM FAILURE BY SHEATHING AND/ OR SHORING, OR OTHER METHODS AS REQUIRED. THE DESIGN ENGINEER ACCEPTS NO RESPONSIBILITY FOR THE SArETY OF EXISTING STRUCTURES. 5). THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENT OR REQUIRED SETBACK AREAS. PLOT PLANS NOT PREPARED FROM LEGAL SURVEYS OF THE EXISTING LOT AND RESIDENCE ARE SO INDICATED. POOL CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND ESTABLISH LOT LINES. IF NECESSARY, POOL CONTRACTOR AND /OR OWNER SHALL VERIFY AND ALL DIMEMSIONS PRIOR TO CONSTRUCTION. 6). CONTRACTOR SHALL ESTABLISH LOCATIONS OF UTILITIES AT THE SITE MINIMUM CLEARANCE DIMENSIONS SHALL BE HELD AND SHALL BE AS REQUIRED BY THE LOCAL REGULATORY AGENCY. IN GENERAL, HOLD A DISTANCE OF 10' FROM OVERHEAD ELECTRIC LINES TO POOL'S WATER EDGE. 7). ALL POOL ENCLOSURES SHALL CONFORM TO FLORIDA STATUTES 515.27 AND 515.29., AND F.B.C. CHAPT 424.2.17.1 -10. 8). WHERE POOLS ABUT OR ARE PLACED NEARBY SEA WALL OR BULKHEADS, SPECIAL CARE SHALL BE EMPLOYED. THE WALLS SHALL BE IN GOOD CONDITION, NOT PERMITTING ANY SHIFTING OR REMOVAL, OR LOOSENING OF THE SUPPORTING SOIL AWAY FROM THE POOL. IF THE WALLS DO NOT FULLY CONTAIN THE SOILS BEHIND THEM, THEY SHALL BE REPLACED OR REPAIRED. CONTINUAL MAINTENANCE OF THE WALLS IS REQUIRED BY THE PROPERTY OWNER. WHEN EXCAVATING FOR THE POOL, THE SEA -WALL TIEBACKS SHALL NOT BE CUT. WHEN DEADMEN FALL WITHIN THE EXCAVATION, NOTIFY THE ENGINEER IMMEDIATELY FOR FURTHER INSTRUCTIONS. 9). THE CONTRACTOR SHALL BACKFILL POOL SHELL WITH CAUTION. THE PLUMBING SHALL NOT BE DISTURBED. BACKFILL SHALL BE PERFORMED WITH CLEAN SAND, FREE OF ORGANIC MATERIALS AND SHALL BE PLACED IN 12 INCHES THICK LAYERS EACH LAYER SHALL BE COMPACTED TO 90% OF THE SOILS MAXIMUM DENSITY BY TAMPERING SOLIDLY. SOILS BELOW THE DECK SHALL BE PLACED IN SIMILAR MANNER. 10). WHERE DECKS ARE INDICATED BY OTHERS, THE DECK DESIGN NOTES SHOWN ON THE TYPICAL SECTION DO NOT APPLY. DECK DESIGN SHALL BE BY OTHERS. 18). TEMPERATURE OF SPA WATER SHALL BE SET SO THAT MAXIMUM WATER TEMPERATURE DOES NOT EXCEED 102 DEGREES FAHRENHEIT. 19). UPON VISUAL INSPECTION SITE SOIL REVEALS A COMBINATION OF UNDISTURBED SAND AND LIMEROCK. A BEARING VALUE OF 2000 PSF HAS BEEN UTILIZED FOR DESIGN PURPOSES. 20). ALL TREADS SHALL HAVE SLIP - RESISTING SURFACES PER ANSI/NSPI-5-2003. 6.1.5 21). ACCESS GATE REQUIREMENTS PER F.B.C. 424.2.17.1.8 AMENDED 06- 03 -03: - GATES SHALL BE EQUIPPED WITH A SELF - LATCHING & LOCKING DEVICE, 54" ABOVE FINISH GRADE ELEVETION. - THE DEVICE SHALL BE PLACED ON THE POOL SIDE OF THE GATE. - GATES SHALL OPEN OUTWARD AWAY FROM POOL. - THE GATE SHALL HAVE NO OPENINGS GREATER THAN 1/2" WITHIN 18' OF THE RELEASE MECHANISM. 22). THIS POOL HAS BEEN DESIGNED TO ALL APPLICABLE REQUIREMENTS OF THE FLORIDA BUILDING CODE, SECTION 424. 23). ALL DETAILS SHOWN ON PAGE 3 OF 3 OF THIS PLAN ARE NOT TO SCALE. 11). DO NOT DRAIN POOL UNDER HIGH GROUND WATER OR STORM CONDITIONS. 12). WARNING! DO NOT EMPTY POOL AFTER CONSTRUCTION FOR REPAIRS OR ANY OTHER REASON BEFORE CONSULTING WITH A POOL OR POOL REPAIR CONTRACTOR. HYDROSTATIC UPLIFT PRESSURES MUST BE ELIMINATED TO PREVENT POOL FROM FLOATING ABOVE GROUND, AND CAUSING DAMAGE TO THE STRUCTURAL INTEGRITY OF THE POOL 13). THIS PLAN REMAINS THE PROPERTY OF THE DESIGN ENGINEERS. IT IS NOT TRANSFERABLE FROM ONE CONTRACTOR TO ANOTHER WITHOUT THE WRITTEN PERMISSION OF THE DESIGN ENGINEERS. 14). ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE F.B.C., 2002 EDITION, AND ARTICLE 680 N.E.C., 2002 EDITION. ALL BOND WIRES SHALL BE PROTECTED WITH APPROVED MATERIAL. THE CONTRACTOR SHALL INSURE THAT AN ELECTRICAL BONDING INSPECTION IS CALLED FOR AN APPROVED PRIOR TO PLACEMENT OF CONCRETE OVER THE BOND WIRE CONNECTIONS. CONNECTIONS DIRECTLY FROM THE POOL LIGHT TO A TRANSFORMER BOX IS PROHIBITED. ALL METAL PARTS IN THE POOL AREA, IN ADDITION TO ALL METAL DOORS, WINDOWS, SCREENED ENCLOSURES, OR OTHERS ITEMS CONTAINING METAL WITHIN A DISTANCE OF 5 FEET FROM POOL WATER'S EDGE, SHALL ALSO BE GROUNDED. 15). POOL LIGHT TO BE GROUNDED TO COMMON BONDING GRID CONSISTING OF (1) #8 CONTINUOUS COPPER WIRE LOOPED AROUND POOL PERIMETER. LOOP SHALL BE GROUNDED TO PANEL VIA POOL WALL STEEL, DECK REINFORCING,AND PUMP MOTOR CASING. 16). FILTER BACKWASH SHALL COMPLY WITH THE FLORIDA BUILDING CODE, 2001 EDITION. 17). POOL WATER DISPOSAL TO BE IN ACCORDANCE WITH FLORIDA BUILDING CODE, 2001 EDITION. CHAIN LINK FENCE 'Ni GATES (SEE NOTE 21) NEW CHAIN - LINK GATE 5' NEW CHAIN 5' EXIST. CHAIN 15 0' LINK FENCE LINK FENCE BY OTHERS TO REMAIN O sf 00'- O'sROPE TY LI _ _t TRASH BABY _ HERE FENCE 51' -0' 54' -0" 5' EXIST. WOOD FENCE TO REMAIN EXIST. OVERHEAD POWER SERVICE EXIST. 200 AHOUSE PANEL EXIST. ELECTRIC METER - 1 M POOL DECK 12.06' �a- JJr 0 POOL 0 0 RESIDENCE L.F.F. ELEV. = 12.56' GARAGE L.F.F. ELEV. = 10.11' NEW CHAIN LINK FENCE W/ GATES (SEE NOTE 21) -11 I� LL 100. -0' PROPERTY LINE 0 1 PIE • 3' -0' 16-0' -J XISTING EPTIC TANK EXISTING DRAIN FIELD SITE PLAN SCALE: I "= 20' -0' 5' EXIST. CHAIN. LINK FENCE TO REMAIN EXIST. WATER LINE EXIST. WATER METER 5' EXIST. CHAIN LINK FENCE TO REMAIN '3 it4ItIP SHEET 1 OF 3 VAN KIRK & SONS, INC. POOL DATA CHART POOL SPECIFICATIONS: POOL SIZE: 15' -0" X 30' -0" POOL DEPTH: 3' X 5' POOL PERIMETER: 90' POOL SQ. FTG: 450 POOL GALLONS: 13,464 TURNOVER RATE: 3.0 HRS± POOL RETURN: 3 SKIMMER: 1 POOL LIGHT: (1) SAM INTERIOR FINISH: GEM CHLORINATOR TYP: N/A WATERLINE TILE: 6" CAP TILE ON SWIMOUT: YES (2) DECK JETS VAC LINE: YES COPING TYPE: V.K. B/N DECK TYPE: V.K. PAVERS POOL ENCLOSURE: FENCE BY- OWNER CHAINLINK FENCE BY- OTHERS PUMP SIZE: 1.5 HP FILTER SIZE: 160 CART POOL M.DS: 2 YKA CONSiJLTING ENGINEERS, INC. 6500 WEST ROGERS CIRCLE ST. 8000 BOCA RATON, FLORIDA 33487 TEL. 561. 998.0805 YEKTA KAVASOGLU P.E. P.E. # 41310 CA# 06141 S1 # 0852 E -MAIL: YKACE @BELLSOUTH.NET 423 SHORES LLC LOT: 15 & 16 / BLOCK: 50 SUBDIVISION: MIAMI SHORES SECTION NO. 423 N.E. 92nd STREET MIAMI SHORES, FL. 33138 DATE: 12/12/05 ORDER: 554 ° A. YEKTA KAVASOGLU P.E. # 41310 YKA #: 05 -462 SALESMAN: STEVE S. VEDAT DEMIREL, PhD, P.E P.E. # 49522 DRAWN BY: LAN REVISIONS: 1) 02110/ MOVEP /E CLOSER NCE NOT 6 , NS (SEE PLAN) DATE: 02/10/06 151-0" 0 0- CHAIN LINK FENCE W/ GATES (SEE NOTE 21) NEW CHAIN LINK GATE TRASH HERE EXIST. OVERHEAD POWER SERVICE 5' EXIST. WOOD FENCE TO REMAIN 14'40" PROPERTY LINE GFCI RECEPTABLE SHALL BE LOCATED ,mmissolowsussear NOT CLOSER THAN AW-' 10' NOR MORE THAN 20' FROM WATER EDGE EXIST. 200 A HOUSE PANEL \,‘ EXIST. ELECTRIC METER r POOL DECK e 12.06' EXISTING ROOF 0 0 0 1 31-0" 0 0 5' NEW CHAIN 5' EXIST. CHAIN LINK FENCE LINK FENCE BY OTHERS TO REMAIN 301-0" r rt N DECKING LINE 31-0" 1 #1Q-*----(2) DECK JETS § et -1-1/2" VENT LINE § VERIFY LOCATION/ IN FIELD L L J L RESIDENCE L.F.F. ELEV. =1256' GARAGE L.F.F. ELEV. = 10.11' 301-6' 1 -k 1 k- -k 1 -- -1. 1 1 1 1 111 I p. P/E 1 /5' EXIST. CHAIN § LINK FENCE / TO REMAIN BABY FENCE EXIST. WATER LINE 0 VAN KIRK & SONS, INC. 0 POOL PLAN SCALE 1/4"--11-0" FITTING CHART YKA CONSULTING ENGINEERS, INC. 6500 WEST ROGERS CIRCLE ST. 8000 BOCA RATON, FLORIDA 33487 TEL. 561. 998.0805 YEKTA KAVASOGLU P.E. P.E. # 41310 CA# 06141 Si # 0852 E-MAIL: YKACE@BELLSOUTH.NET 423 SHORES LLC LOT: 15 & 16 1 BLOCK: 50 SUBDIVISION: MIAMI SHORES SECTION NO. 00000G Gjvavir:.. w0000 0 0 0 0 423 N.E. 92nd STREET 0 0 0 00 MIAMI SHORES, FL. 33138 DATE: 12/12/05 ORDER: 554 A. YEKTA KAVASOGLU P.E. # 41310 YKA #: 05-462 SALESMAN: STEVE S. VEDAT DEMIREL, PhD, P.E P.E. # 49522 DRAWN BY: LAN REVISIONS: 1). 02/10/06-MOVE P/E CLOSER TO HOUSE, 5' FENCE NOT 6' , MOVE FENCE LOCATIONS (SEE PLAN) DATE: 02/10/06 0 POOL VENTLINE: POOL RETURNS: DECK JET #1: DECK JET #2: POOL LIGHT: POOL SKIMM: POOL VAC: POOL M.DIS: TOTAL OF PIPES: 1-1/2" PIPE = TO BE VERIFY 1-1/2" PIPE = 78`-6" LENGTH 1-1/2" PIPE = 54'-0" LENGTH 1-1/2" PIPE = 62'-6" LENGTH 1" PIPE = 30'-0" LENGTH 2" PIPE = 71'-0" LENGHT 2" PIPE = 29'-6" LENGTH 2" PIPE = 53J-0" LENGTH - 378'-6" LENGTH 90° (I" PIPE) = 90° (1-1/2" PIPE) = 90° (2" PIPE) = 2 TEES (1-1/2" PIPE) = 3 9 TEES (2" PIPE) = 1 9 FITTING CHART YKA CONSULTING ENGINEERS, INC. 6500 WEST ROGERS CIRCLE ST. 8000 BOCA RATON, FLORIDA 33487 TEL. 561. 998.0805 YEKTA KAVASOGLU P.E. P.E. # 41310 CA# 06141 Si # 0852 E-MAIL: YKACE@BELLSOUTH.NET 423 SHORES LLC LOT: 15 & 16 1 BLOCK: 50 SUBDIVISION: MIAMI SHORES SECTION NO. 00000G Gjvavir:.. w0000 0 0 0 0 423 N.E. 92nd STREET 0 0 0 00 MIAMI SHORES, FL. 33138 DATE: 12/12/05 ORDER: 554 A. YEKTA KAVASOGLU P.E. # 41310 YKA #: 05-462 SALESMAN: STEVE S. VEDAT DEMIREL, PhD, P.E P.E. # 49522 DRAWN BY: LAN REVISIONS: 1). 02/10/06-MOVE P/E CLOSER TO HOUSE, 5' FENCE NOT 6' , MOVE FENCE LOCATIONS (SEE PLAN) DATE: 02/10/06 0 0 0 0 0 0 0 0 0