MECHANICALPERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Date / _ / 5Job Address
Legal Description Historically Designated: Yes No
Owner/Lessee / Tenant , Master Permit # 3 Owner's Address 13'JO(/ 4//` Phone 69r-- / YY
Contracting Co. (r)62) /O (IL Address
Qualifier SS# - Phone
State # Municipal # Competency # Ins. Co.
Architect/Engineer Address
Bonding Company Address
Mortgagor Address
Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING ENCE SIGN
WORK DESCRIPTION A da l / n e el4 7ra
Square Ft
S
FEES: PERMIT , RADON
tf6 T /(/ LE Tax Folio
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.)
Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I
certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable
laws regulating structio and zonir. Furthermore, I authorize the above -named contractor to do the work stated.
-?
Si e of owner and/or " ondo 'r "sident Date
-- 7 otary as to Owner and/or Condo President Date
My Com niss*IlYli irc FICIAL NOTARY SEAL
0 e■ SANDRA M MONTIEL
.: III j � '• Q w * COMMISSION NUMBER
CC401261
7 t ' QQ MY COMMISSION .EXP.
`�G ......... 0F11,...._2119 .;....
17,1998
Estimated Cost (value) yl Ree9 " 0 !/
•
Signature of Contractor or Owner- Builder Date
Notary as to Contractor or Owner - Builder Date
My Commission Expires:
0
C.C.F. 1 • NOTARY
I a S D
5. TOTAL DUE
APPROVED:
Zoning / Building Electrical
Mechanical / — Plumbing Engineering
iami J ores9illage
0 w 1 0 A
Sec. 5-1.1. Air conditioning regulations.
(a) All individual air conditioning units installed in walls or
windows shall be securely anchored to the walls by approved
methods. Units installed over public property, paths of egress or
more than ten (10) feet above grade shall be secured to the struc-
ture by bolts or screws to resist horizontal wind loads. Such units
cantilevering more than eight (8) inches on the exterior of a
building shall be supported by steel angle brackets secured by
bolting. Bolts to masonry shall be set in lead shields or similarly
rot - resistant fastenings.
(b) The following special requirements shall apply to the con -
tml and regulation of noise nuisance from air conditioning machinery:
(1) All equipment, existing or hereafter installed, regardless
of location, shall be maintained in good working order.
Equipment so located that normal operating noises ceate
a nuisance to adjacent owners or occupants shall be pro-
vided with. soundproofing, or sound - absorbing baffels, or
enclosures, as approved to insure maintenance of a rea-
sonable noise level.
(2) All equipment on outer walls, on roofs, or in other exposed
locations, which are unduly noisy , and which causes valid
complaints from adjoining property owners or occupants,
may be required to be relocated, redesigned and!or en-
. closed in noise- retarding materials when, in the opinion of
the building official, such enclosure is necessary or would
be effective.
,(3) Special consideration shall be given to the punning of all
future installations to rninirnizp the noise nuisance to ad-
joining property owners or occupants, and the building
official shall have authority to reject or require the rede-
sign of any system which, in his opinion, would cause such
a.noise nuisance.
(c) Violation of this section shall be punished as is now or may
hereafter be provided by law. (Ord. No. 299, §§ 1 -3, 2- 21-61)
I have read the above ordinance and will comply with the
regulations thereof.
.
Contractor Siitjx,atura
Department of Community Affairs SN: 6139
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
FORM 600A -93 Residential Component Prescriptive Method A SOUTH
PROJECT NAME: DAWSON RESIDENCE :BUILDER:
AND ADDRESS: 469 NE 93RD STREET :PERMITTING :CLIMATE
MIAMI SHORES :OFFICE: MIAMI SHORES :ZONE: 7:_: 8K, 9:_:
OWNER: MR. $c MRS. DAWSON :PERMIT NO. :JURISDICTION NO.232600
CK
1. New construction or addition 1. New Construction
2. Single family detached or Multifamily attached 2. Single - Family
3. If Multifamily -No. of units 3. 0
4. If Multifamily, is this a worst case (yes /no) 4.
5. Conditioned floor area (sq.ft.) 5. 1731.00
6. Predominant eave overhang (ft.) 6. 0.00
7. Porch overhang length (ft.) 7. 0.00
8. Glass area and type:
a. Clear Glass
b. Tint, film or solar screen
9. Floor type and insulation:
14.Heating System:
15.Hot water system:
16.Hot Water Credits: (HR -Heat Recovery, 16.
DHP- Dedicated Heat Pump)
17.Infiltration practice: 1, 2 or 3 17. 2
18.HVAC Credits (CF- Ceiling Fan, CV -Cross vent, 18. CF
HF -Whole house fan, RB -Attic radiant
barrier, MZ- Multizone)
19.EPI (must not exceed 100 points) 19.
a. Total As_Built points 19a.
b. Total Base points 19b.
I Hereby certify that the plans and
specifications covered by this calcu-
lation are in compliance with the
Florida Energy Cod
PREPARED BY:_
= f5
Single Pane Double Pane
8a.341.Osgft 0.00sgft
8b. 0.Osgft 0.00sgft
b. Wood, raised (R- value, area ) 9b.R= 0.00 , 1731.00 sqft
10.Net Wall type area and insulation:
a. Exterior: 1. Concrete (Insulation R- value) 10a -1 R= 4.20, 1297.00sgft____
11.Ceiling type area and insulation:
b. Single assembly (Insulation R- value) 11b.R =19.00 , 1731.O0sgft____
12.Air distribution systems
a. Ducts (Insulation + Location) 12a. R= 0.00 , cond
13.Cooling system 13. Type: Central A/C
SEER: 11.15
98.95
28628.33
28933.28
14. Type: Strip Heat
COP: 1.00
15. Type: Electric
EF: 0.89
: Review of the plans and specifications
: covered by this calculation indicates
: compliance with the Florida Energy
1 Code. Before construction is completed
: this building will be inspected for
544 compliance in accordance with Section
: 553.908 F.S.
I hereby certify that this building is :
in compliance with the Florida Energy :
Code.
OWNER /AGENT: Z A:t4VgdeC[l, 45E, : BUILDING OFFICIAL:
DATE: • g' -} -RS 4071 : DATE:
' ** -INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST **
COMPONENTS
PRACTICE #1
Windows
Exterior &
Adjacent Doors
Exterior Joints
& Cracks
PRACTICE #2
Exterior Walls
& Floors
Exterior Walls
& Ceilings
DuctWork
Fireplaces
Exhaust Fans
Combustion
Appliances
Water Heaters
Swimming Pools
& Spas
Shower Heads
HVAC Duct
Construction
Insulation &
Installation
HVAC Controls
Insulation
SECTION
REQUIREMENTS FOR EACH PRACTICE CHECK
606.1 COMPLY WITH ALL INFILTRATION PRESCRIPTIVES.
606.1 Maximum of 0.34 CFM per linear foot of operable sash
crack (includes sliding glass doors).
606.1 Maximum of 0.5 CFM per sq. ft. of door area: solid
core, wood panel,insulated or glass doors only.
606.1 To be caulked, gasketed, weather-stripped or other-
wise sealed.
606.1 COMPLY WITH PRACTICE #1 AND THE FOLLOWING:
606.1 Top plate penetrations sealed. Infiltration barrier
installed. Sole plate/floor .joint caulked or sealed.
606.1 Penetrations, joints and cracks on interior surface
caulked, sealed or gasketed.
606.1 Ductwork in unconditioned space must be sealed.
606.1 Equipped with outside combustion air, doors and flue
dampers.
606.1 Equipped with dampers. Combustion devices see
606.1.A.2.
606.1 Be in unconditioned space (except direct vent), draw
air from unconditioned space, exhaust to outside.
Cooking appliances shall be dampered and use
intermittent ignition.
** OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) **
612.1 Comply with efficiency requirements in Table 6-12.
Switch or clearly marked circuit breaker (electric)
or cutoff (gas) must be provided. External or built-
in heat trap required.
612.1 Spas and heated pools must have covers (except solar
heated). Non-commercial pools must have a pump timer.
Gas spa & pool heaters must have a minimum thermal
efficiency of 78 percent.
612.1 Water flow must be restricted to no more than 3 gal-
lons per minute at BO PSIG.
610.1 All ducts, fittings, mechanical equipment and plenum
chambers shall be mechanically attached, sealed, ins-
ulated and installed in accordance with the criteria
of Section 610.1.ABC.2 & 610.4.ABC.3. Duct in attics
must be insulated to a minimum of R-6. Air handlers
shall not be installed in attics unless in mechanical
closet.
607.1 Separate readily accessible manual or automatic
thermostat for each system.
604.1 Ceilings minimum R-19. Common Walls - Frame R-11 or
602.1 CBS R-3 both sides. Common ceiling & floors R-11.
43****************************************************************************
SUMMER CALCULATIONS
,
=== BASE === === AS-BUILT ===
1
GLASS
ORIEN AREA x BSPM = POINTS : TYPE
N 96.00
E 86.00
S 68.00
W 91.00
109.7 10531.2 1 SGL CLR
109.7 9434.2 1 SGL CLR
109.7 7459.6 1 SGL CLR
109.7 9982.7 1 SGL CLR
N
E
S
W
. 15 x COND. FLOOR / TOTAL GLASS = ADJ. x GLASS =
AREA AREA FACTOR POINTS
. 15 1,731.00
NON GLASS
AREA x BSPM = POINTS TYPE
WALLS
Ext 1297.0
DOORS
Ext 43.4
CEILINGS
UA 1731.0
FLOORS
Rsd 1731.0
INFILTRATION
1731.0
TOTAL SUMMER POINTS
TOTAL x
SUM PTS
53,928.11
341.00 .761
1.6 2075.2 1 Ext NormWtBlock In
6.4 277.8 Ext Wood
Ext Wood
-2.2 -3739.0 1 Rsd Wood (Stem-SWI
14.7 25445.7 1 Practice #2
53,928.11
SC ORIEN AREA x SPM x SOF = POINTS
=
37,407.70
96.0
86.0
68.0
91.0
R -VALUE
64.5
136.3
135.6
136.3
ADJ GLASS
POINTS
28,483.61 1 39,537.90
=
AREA x SPM = POINTS
4.2 1297.0 2.28
26.7 9.40
16.7 9.40
.8 1384.8 1 Single Assembly 19.0 1731.0 2.50
1.00 6192.0
1.00 11721.8
1.00 9220.8
1.00 12403.3
GLASS
POINTS
2957.2
251.0
157.0
4327.5
.0 1731.0 -4.20 -7270.2
1731.0 14.70 25445.7
65,406.02
SYSTEM = COOLING TOTAL x CAP x DUCT x SYSTEM x CREDIT = COOLING
MULT POINTS 1 COMPON RATIO MULT MULT MULT POINTS
.37 19,953.40 1 65,406.02 1.00 1.000 .307 .860 17,268.50
*****44**********************************************************************
WINTER CALCULATIONS
,
=== BASE === === AS-BUILT ===
s
GLASS
ORIEN AREA x BWPM = POINTS : TYPE SC ORIEN AREA x WPM x WOF = POINTS
N 96.00 -.4 -38.4 : SGL CLR N 96.0 3.7 1.00 355.2
E 86.00 -.4 -34.4 : SGL CLR E 86.0 .1 1.00 8.6
S 68.00 -.4 -27.2 1 SGL CLR S 68.0 -2.0 1.00 -136.0
W 91.00 -.4 -36.4 1 SGL CLR W 91.0 .1 1.00 9.1
. 15 x COND. FLOOR / TOTAL GLASS = ADJ. x GLASS = ADJ GLASS 1 GLASS
AREA AREA FACTOR POINTS POINTS , POINTS
. 15 1,731.00 341.00 .761 -136.40 -103.86 1 236.90
NON GLASS
AREA x BWPM = POINTS 1 TYPE R-VALUE AREA x WPM = POINTS
WALLS
Ext 1297.0 .3 389.1 1 Ext NormWtBlock In 4.2 1297.0 1.02 1322.9
DOORS
Ext 43.4 1.8 78.1 1 Ext Wood 26.7 2.80 74.8
Ext Wood 16.7 2.80 46.8
CEILINGS
UA 1731.0 .1 173.1 1 Single Assembly 19.0 1731.0 .30 519.3
FLOORS
Rsd 1731.0 -.3 -484.7 1 Rsd Wood (Stem-SWI .0 1731.0 .30 519.3
INFILTRATION
1731.0 1.2 2077.2 Practice #2 1731.0 1.20 2077.2
TOTAL WINTER POINTS
TOTAL x SYSTEM = HEATING TOTAL x CAP x DUCT x SYSTEM x CREDIT = HEATING
WIN PTS MULT POINTS 1 COMPON RATIO MULT MULT MULT POINTS
2,128.98 1.10 2,341.88 1 4,797.16 1.00 1.000 1.000 1.000 4,797.16
2,128.98 1 4,797.16
*******************************************************************************
WATER HEATING
*******************************************************************************
=== BASE === === AS-BUILT ===
NUM OF x MULT = TOTAL 1 TANK VOLUME EF TANK x MULT x CREDIT = TOTAL
BEDRMS
RATIO MULT
2 3319.0 6,638.00 : 40 .89 1.000 3281.3 1.00 6,562.67
*******************************************************************************
SUMMARY
*******************************************************************************
=== BASE ===
=== AS-BUILT ===
COOLING HEATING HOT WATER TOTAL 1 COOLING HEATING HOT WATER TOTAL
POINTS + POINTS + POINTS = POINTS 1 POINTS + POINTS + POINTS = POINTS
19953.4 2341.9 6638.0 28,933.28 1 17268.5 4797.2 6562.7 28,628.33
t**t*********ttt*
* EPI = 98.95 *
F or - detailed information
of the EPI rating number
or for any ITEM listed,
ask your Builder for
DCA Form 600A -93
or Form 600B -93
OTHER FEATURES
ENERGY GUIDE
EPI= 98.9
0 10 20 30 40 50 60 70 80 90 100
X
The maximum allowable EPI is 100. The lower the EPI the more efficient the home
RESIDENTIAL ENERGY PERFORMANCE RATING SHEET
ITEM HOME VALUE Low Efficiency High Efficiency
SINGL CLR DBL TINT
WINDOWS Single Clear IX
INSULATION
R -10 R -30
Ceiling R -Value 19.0 1 X
R -0 R -7
Wall R -Value 4.2 1 X
R -0 R -19
Floor R -Value 0.0 :X
AIR CONDITIONER
10.0 SEER 17.0
SEER/EER 11.1 : - - -X
9.7 EER 16.0
HEATING SYSTEM
2.50 COP 4.19
Electric COP /HSPF 1.0 IX
0.78 AFUE 0.90
Gas AFUE 0.00
WATER HEATER
0.88 0.96
Electric EF 0.89 1 - -X
0.54 0.90
Gas EF 0.00 1
0.40 0.80
Solar EF
I certify that these energy saving features required fo t e Florida
Energy Code have been installed in this house.
Address: Signature: Date: ,
Builder
r
City /Zip
Florida Energy Code for Building Construction - 1993
Florida Department of Community Affairs
FL -EPL CARD93
,
: t RESMANUJ t'_) :$
WHOLE HOUSE
HEAT GAIN / HEAT LOSS CALCULATION USING EPI92- FLA /RES(c) DATA FILES
(BASED ON A.C.C.A. MANUAL J - SEVENTH EDITION (c) 1986 by A.C.C.A.)
PROJECT :DAWSON RESIDENCE
ADDRESS :469 NE 93RD STREET
CITY :MIAMI SHORES
OWNER :MR. & MRS. DAWSON
BLDG CONTR :
HVAC CONTR :
Geographical Location : Florida : Miami - AP
North Latitude / Elevation 25 Deg. / 9 Ft. Above Sea Level
Outdoor Winter Dry Bulb 48 Deg. F
Indoor Winter Dry Bulb : 70 Deg. F
Winter (Actual) Temp.Diff. 22 Deg. F
Winter Temp. Diff. (wTd) : 40 Deg. F
Outdoor Summer Dry Bulb 89 Deg. F
Outdoor Summer Wet Bulb : 77 Deg. F
Outdoor Summer Humidity Ratio 122
Indoor Summer Relaltive Humidity : 50%
Indoor Summer Design Grains / Lb. : 56
Indoor Summer Dry Bulb 75 Deg. F
Indoor Summer Wet Bulb : 62.3 Deg. F @ 64 Gr /Lb
Summer Daily Range 15 Deg. F - L
Summer (Actual) Temp.Diff. 14 Deg. F
Summer (User Sel) Temp.Diff. (sTd) : 20 Deg. F
SUBTOTAL
* HEATING SUMMARY * * COOLING SUMMARY *
DUCT LOSS
TOTAL LOSS /BTUH
Conditioned Floor Area : 1731 SF
* Climatic Conditions & Design Conditions *
SERIAL # 6139
59651.68 STRUCTURE SENSIBLE 38477.47
:MECH.VENT- 0 Cfm 0.00
:SENS. + MECH.VENT : 38477.47
:TEMP.SWING @ 3 DEG. : 1.00
:OCCUPANT /APPLIANCE 2400.00
0 :DUCT GAIN 0.00
: 59651.68 :TOTAL SENSIBLE : 40877.47
:TOTAL LATENT : 3892.17
:SENSIBLE + LATENT : 44769.64
207. OVERSIZE FACTOR : 11930.34 :20% SENS.OVRSZE FTR: 8175.49
ACTUAL + 20% OVERSIZE: 71582.02 :SENS. + 207 OVERSIZE: 49052.96
* EQUIPMENT SELECTION *
EQT. MANUF. MODEL # TYPE
HTG INPUT HTG OUTPUT AFUE /HSPF
SENSIBLE CLG LATENT CLG TOTAL TONAGE___
(S)EER CLG CFM HTG CFM
NOTES: GLASS /SF RATIO = 2%
•
G LASS
TYPE Inside Shade Sc Area
South Single Clr Roller Shade
West Single Clr Roller Shade
North Single Clr Roller Shade
East Single Clr Roller Shade
Infiltration : Winter Htm ( 19.36 )
Infiltration : Summer Htm ( 4.47 )
Window Frame : Metal SUBTOTALS:
W ALLS
N/W C.B. - Int Insul - Ext. 4.2
D OORS
Solid Core/Wood - Ext. 0
Solid Core/Wood - Ext. 0
Infiltration :Winter Htm( 19.36 ) x
Infiltration :Summer Htm( 4.47 ) x
CEILINGS
Single Assembly
FLOORS
* LOAD CALCULATION*
R-Value Area
19
1 68.00
1 91.00
1 96.00
1 86.00
x 341.00
x 341.00
1297.00
26.70
16.70
43.40
43.40
SUBTOTALS: 43.40
1731.00
0 1731.00
* TOTAL STRUCTURE SENSIBLE *
Loss/Btuh Gain/Btuh
3141.60
4204.20
4435.20
3973.20
6601.76
341.00 22355.96
Loss/Btuh
7522.60
760.95
475.95
840.22.00
2077.12
6058.50
21637.50
2312.00
5824.00
2016.00
5504.00
1524.27
17180.27
Gain/Btuh
3761.30
339.09
212.09
194.00
745.18
4154.40
12636.30
59651.68 38477.47