ROOFINGTest Location Uplift Pull Test (P or F) Test Location Uplift Pull Test (P or F) Test Location Uplift Pull Test (P or F) 1 26 51 lF �A 2 27 52 3 28 53 4 29 54 5 30 55 6 31 56 7 32 57 8 33 58 9 34 59 10 35 60 11 36 37 .1 62 12 13 38 63 14 39 64 15 40 65 16 41 17 42 _�6.6 67 18 43 68 19 44 69 20 45 70 21 46 71 22 47 72 23 48 73 24 49 74 25 50 75 Du & Associates, V 7 ial inc. . Consulting Engineers Environmental • Civil • Structural Testing Laboratory Bu4clin Inspection Services ON -SITE CONCENTRATED UPUFT LOAD TESTING OF ROOF TILE IN ACCORDANCE WITH METRO-DADE BUILDING CODE COMPLIANCE PROTOCOL PA 106 SITE SPECIFIC INFORMATION Owner's Name: .P ( k`7 trA v S Permit Job Address 3 55 N 1~ °l 3 ST. , I"i l AI., 1 E4 `e- 1 Roofing Contractor A tt t ,- Cs Type of Tile: 1'D kt-t. SE T Approximate Roof Height' Type of Access to Roof: Approximate Square Footage Required Testing Force: 35 Ibs Date Tested. 5 • 2 • 1 feet Scaffolds of Roof Z D D ft orge Du Quesne, P. vil Engineer .E. #24513 Du Quesne & Associates, Inc. E.B. License #0005245 Lab Certification #94- 0318.01 Ladder Testing Equipment: Chatillion DFIS 100 TEST RESULTS P = PASS, F = FAIL SKETCH OF ROOF IN BACK # 44 13 ( 3 UTR 15959 Date Installed 7 ' 27 - •q • Roof Pitch 3'• l2 Other IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. THIS PA 106 TEST HAS BEEN PERFORMED IN FULL ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTY, WITH NO DEVIATIONS. Please Note: This form is not valid unless Company logo appears in color (burgundy) 7815 S.W. 24th Street • Suite 109 • Miami, Florida 33155 • Telephone (305) 264 -1425 • Fax (305) 264 -1426 KETCH OF ROOF JOB SHEET NO OF CALCULATED BY CHECKED BY DATE SCALE DATE NOTES* JOB 3 55 IJ q 4T;, ► .�-oG.e,IF'I SHEET NO. y OF �..-- CALCULATED BY DATE b • 3 • 9 CHECKED BY SCALE U DATE CQ 6 0 cp J $KETCH OF ROOF 40 1- 1 t) NOTES' • PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 4 -26 -99 Job Address 355 N.E. 93 Street TaxFolio // 3 Z , 6 )3 6 2 9t, Legal Description Historically Designated: Yes Master Permit # Phone 757 -0157 Owner/Lessee / Tenant M r. A S m u s Owner's Address 355 N.E. 93 Street Miami Shores Contracting Co. Qualifier • . • • Carlos Arocho State # RC 0 0 5 8 6 2 7 Municipal # Architect/Engineer Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION Tear off old roof to wood deck, tin cap 301b. ASTM install galvanized eave drip and valley metals where required, type TTI agphalt one laver of 901b. ASTM felt, install Spanish tile with adhesive foam setting. Square Ft. 7c) s q _ Estimated Cost (value) 5 10,400.00 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY Tit YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I. certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable egulating constructioryaid zoning. Furthermore, I authorize the above -named contractor to do the work stated. i st A° X Signature //9)99 wner and/or Condo President Date ate Notary as to Con "ctor or Own My Commission Expires: 1 .„ y, MARYLOU HERNANDEZ •; ••■ :,i MY COMMISSION # CC 680474 EXPIRES: October 10, 2001 rd ••''' Bonded Thu Notary Public Underwriters Notary as to er and/or Co SS# Address 13800 N W _ 1st Avenue 751-0382 Competency # 17889 Address Signature of Contractor or Owner- Builder L t d MARYLOU HERNANDEZ = MY COMMISSION # CC 880474 aJ EXPIRES: October 10, 2001 Bonded Thu Notary Public Undenvrftere My Commission Expires: Ins. Co. No ✓ 1 4 1 1 8/ 3 felt as per code mop on with S Clay.Colorhtru 5/i • D ate . NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. /1 3 Z 0 C 0 /3 t, 2 9 0 STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real properly. and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: 3 55 N .E . 9 3 Street 2. Description of improvement: Reroof to a new Tile roof . 3. Owner(s) name and address: MR . Asmus Interest in property: Owner Name and address of fee simple titleholder: N/A 4. Contractors name and address: Quality Roof inq Contractor, Inc . 5. Surety:(Payment bond required by owner from contractor, it any) Name and address: N/A Amount of bond $ 0 0 6. Lender's name and address: N/A 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: N/A 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: N/A 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording, unless a different date I, specifie Signature of nor Print Owners Name O UR-AS L - SM U G Sworn to and subscribed before me this / i' day of MAy 19 9 ( 1 . Notary Public Print Notary's Name My Commission Expires: Miami Shores, Florida 33138 355 N.E. 93 Street Miami Shores, Florida 33138 13800 N.W. 1st Avenue Miami, Florida 33168 1 STATE OF FLORIDA; COUNTY OF DADE I HEREBY CEIMPY that this Is a truo copp tho original filed in this offico on �� /�G� d ' A. O. 19 WIINE$S my h nd and Off Wl:'o MY COMMISSION I CC 680474 F7(PIRES: October 10, 2001 440, Bonded Thu Notary Public Undeswitters HRRRWM..,, ERK, of CI r pit .fnd Counsy C • ,r: ° I' =_ 13 C. st N N i".0 Prepared by: Carlos Arocho Quality Roofing Cnntrar•tor Address: 13800 N.W_ 1st Avenu iami Florid 12301.52 2193 Appendix "E" . 'UNIFORM ROOFING PERMIT APPLICATION PROCESS No. Contractor's Name: a.,1/4a �� # 200 L nkrcirf Job Address: 15..5 9 3 c1 ❑ (Low Slope Application) ❑ (Asphalt/Fiberglass Shingles) • ROOF CATEGORY ❑ (Nail -On Tile) ❑ (Metal Roofs\Wood Shingles & Shakes) R(Mo dherta Set Tile ❑ (Other) / ROOF TYPE ❑ New Roof 2 Re- roofing • • - •❑ Recovering ❑ Repair ❑ Maintenance Flat Roof Area (fe) Sloped Roof Area (ft q SI % Total (ft') 19 Si . Master Permit No. Exposure category (per ASCE 7 -88): � Building Classification category (per ASCE 7 -88 table 1): FL Ft. eck type: ATTACHMENT Fastener Type: $PAC G Field:. Perimeter: Corner: DETAIL 1 & 2 ROOF HEIGHT AND SYSTEM DETAILS • (Draw details as needed) 11 r 1 r r r r r r r 'r i r v tit i �1 ROOF PLAN 123.0148 9/98 Page -1 1 Ridge Ventilation? t)IR 1 MIF.1M HEICHT ° Deck type: z Underlayment isuulatioru D E T A I L 3 Appendix "E" UNIFORM RQ OFING PERMIT APPLICATION • ' ' PROCESS No. SLOPED SYSTEM DESCRIPTION Fastener to & spacing: Cap Sheet: RoofCovering: r Drip edge; Page -2 IaC.tO•C. "1 •C (� q "0.C• t& 1 t - ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations • d) Applicable Detail Drawings 3) Municipal Permit Application • 4) Other Component Approvals (Pmax1: 91.3 x T Aaod , e ( ynamio MultiplIe4.2. ) • .31 (P»:ax2: 0 (Aerodynamics Multiplier) :3 r) 5 t ) (Pmax3: )x ? (Aerodynamio Multiplier): 39.6 - 1 • a jt TILE CALCULATIONS 0)16. Mg:1 iO a Mri: P75I PCA: U M: ° M PCA: OP M • Vi 0 la Ma � 01-a0 ..... v .. • r w ...a V V V V Santafe Tile Corporation Ladrillera Santafe Bogota, Columbia F.xpires: 10/10/94 Approved. In/1 id VV1\111.\Vi. METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE SUITE 1603 METRO DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130.1563 (305) 375.2801 FAX (305) 375 -2908 INTERNET: mdcc0l ershadow.net PRODUCT CONTROL SECTION (305) 375.2902 FAX (305) 372 -6339 Your application for Product Approval of: Santafe Tile Corp. /Tall - -On, Mortar Set or Adhesive Set "Scn~'oje S" Roofing Tile under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specificatipns and calculations as submitted by: The Center for Applied Engineering, Inc. and Testwel! Craig 1.aboratorles & Consultants has been recommended for acceptance by the Building Code Compliance Department to be used in Dade County, Florida under the specifio conditions set forth on pages 2 through 11 and the standard conditions set forth on page 12. The approval shall not be valid after the expiration date sta ed below. The Building Code Compliance Office reserves the right to secure this product or material at any time for a jobsite or manufacturer's plant for quality control testing. if this product or material fails to perform in tie approved manner, the Building Code Compliance Office may revoke, modify or suspend the use of such product or material immediately. The applicant shall re- evaluate this product or material' should any amendments to -he South Florida Building Code be enacted affecting this product or material. The Building Code Compliance Off ce reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this roduct or material fails to meet the requirements of the South Florida Building Code, The expense of such testing iIII be Incurred by the manufacturer. Acceptance No.: 96.011891 Revises No. .94- 1017.07 Raul Rodt'fguez Product Control Supervisor This application for Product Approval has been reviewed y the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code 4ommittee to be used in Dade County, Florida under the conditions set forth above. Charles Danger, P.E. Director Building Code Compliance Dept. Metropolitan Dade County Applicant: Santafe Tile Corporation Ladrillera Santafe Bogota. Columbia Category: Suh- Category. Type: Sub -Type. .. ROOFING SYSTEM APPROVAL Prepared Roofing High Profile Tile Nail- on/Mortar Set/Adhesive Set Clay Contact: Daniel Bernal General Manager Santafe Tile Corporation 7225 Northwest 2Stlt Street, Suite #306 Miami, Florida 33122 (305) 593 -9339 Product Control No.: 96. 0318.02 Product Control No Approval Date: Expiration Date: uloaga ?'ins Exa:*.' ^er. Pr uc: Ccn:rc! Div. Q� 0318.02 Q.rloher 10.1996 October 101999 Ladrillera Santafe, located In Bogota, Columbia, manufa urers clay roof tile for nail -on and adhesive set applications. All Ladrillera Santafe tiles are available n standard unglazed and a glazed color finish. "Santafe S" tile profile Refer to appropriate eroduc/ Control Approvals for other tile Ladrillera Santaf6 tile profiles have matching trim pi ces used for rake hip, ridge hip. and valley terminations. These accessories form a part of this Product Control Approval. 1 The Ladrillera Santafe's "Santaf6 S" tile profile has been tested in compliance with the South Florida Building Code requirements for clay, nail -on and adhesive set tile applications. The minimum roof slope for Ladrillera Santaf6's "Santaf6 S" nail -on tiles shall be 4 ": ". The minimum roof slope for Ladrillera Santafe's "Santaf6 S" adhesive set tiles shall be 2 ":12" Sie the "Profile Drawing" section in this approval for the "Santafe S" profile drawing. The "Santafe Si tile profile has been tested for static uplift performance only. Therefore, any consideration for ipstallatlon shall be done as an 'Uplift Based Syrem'. Data for attachment calculations is noted in Tables 1 and 2 of this approval. Santa Fe Tile Corporation is the sole. approved distributo of Ladrillera Santafe roof tiles. Test Product product f imencinni Speriftratien4 Description Santafd 'S' Clay Roof 1 IN 18" ASTM C 167 High profile, interlocking, one•plece, Tile w • 11'W' 'S' shaped, clay roof tile equipped with W thick two nail holes and a single roll. For nail -on, mortar set and adhesive set applications. Trim Picccs TRADE NAMES OF PRODUCT S MANUFAt: TUBED OR LABELED BY APLZCANT I s varies w varies varying thiclQtess ASTM C 4167 Product Control No.: 96- 0318.02 Accessory trim, clay roof pieces for use at hips. rakes, ridges and valley terminations. Manufactured for each tile profile. ran •Luloaga Plans Examiner. Product Cor.trel Div. Iv/ IA, ao rlcl U : u4 FAX 305 3726339 BCCD `PRODUCT CONTROL. product #30 Felt It43 Coated Base Sheet Mineral Surface Cap Sheet Mopping Asphalt Flashing Cement Asphalt Primer Rooftng Nails Tin Caps ' TRADE -NAh1ES•OF PRODUCTS Almsnstg N/A N/A N/A N/A N/A N/A Test Satatcapans ASTM D type 1 ASTM D 626 ASTM D249 ASTM D 312 type III or IV ASTM U41 min. 12 ga. with • . PA 114: 3 / 1 " head Appendix E min. 32 ga. min. 1 /4" o.d. max. 2" o.d. M i14, Appendix .E 4 VIANUFACTURED OTHERS Product Control No.: 96- 0318.02 Product Descrtyjlort Manufacturer Saturated organic felt generic to be used as a nailed anchor sheet. Saturated and coated organic base sheet for single or double ply underlayment. Mineral surfaced asphalt roll roofing for use as a top ply in a double ply underlayment system. Asphalt for bonding a mineral surface cap to a mech, attached base sheet in a double ply underlayment system. Cutback, asphalt based coating used to facilitate bonding of dissimilar materials. Annular ring shank, hot dipped. electro or mechanically galy, • roofing nails for use in underlayment attachment. Corrosion resistant circular disc for use in underlayment attachment generic generic generic ASTM D 186 Cut back, asphalt generic based, asbestos free, fiber reinforced, trowel grade cement for repair and flashing applications. generic generic generic Q017 , • _ product . Tile Nails Tile Screws • Roof Tile Mortar ( "Ti!eTiteTM ") Roof Tile Adhesive ( "PolSproe AH160 ") Hurricane Clip & Fasteners Valley Flashing Drip Edge .. Dimension; min. 10d x 3" #8 x 2. long 0.335" head dia. 0.131" shank dia. 0.175" screw thread diameter N/A N/A Clio Fajenets min. 8d x 1 VA" min. 26 ga. thin. 16" width min. 26 ga. min. 2" face flange min. 2" deck flange Test $pecNlcatfnn PA 1141 Appendix PA 114 Appendix E PA 123 See PCA MIS PA 114 min. W' width Appendix E min. 0.060" thick ASTM A 5/5 PA 111 1 Product Control No.: 96. 0318.02 Product Description Corrosion resistant; ring shank nails. Corrosion resistant. coated, coarse thread wood screws, Prepared mortar mix designed for mortar set roof tile applications. Two component polyurethane adhesive designed for adhesive set roof tile applications. Corrosion resistant bronze, aluminum, stainless steel, galvanized steel or plastic attachment clips for supplemental tile attachment. Clips are installed with corrosion resistant roofing nails compatible with the clip. Galvanized steel valley flashing Galvanized steel drip edge ran Zuloaga • . t r ^ Prods.:■ . r.'rcf rD". Manufacturer generic generic Bermuda Roof Company, Inc. with current PCA Polyfoam Products, Inc. with current PCA generic generic generic • Vest &vency The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering. Inc. Tho Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Testwell Craig Laboratories & Consultants, Inc. TEST REPdRTS Test Identifier 25- 7205.4B 25- 7205.4A 94.156 -2 94.156 -1 Project: 07 -07 -00.91 (307023) Lab i MK. Alberto Ramirez Product Control No.: 96- 0318.02 Test Name/Report Dais Static Uplift Testing 04/95 PA 102 (Two Nails) Static Uplift Testing PA 102 (Two Screws) Static Uplift Testing PA 101 (Adhesive Set) Static Uplift Testing PA 101 (Mortar Set) Wind Driven Rain PA 100 Physical Properties ASTM C 1 167 Fr ,take Zulnaga t. r Pr J... ,. 04/95 08194 0.8/94 09/94 08/96 Deck Type: Deck Description: SYSTEM D: Slope Range: Underlaymeat: Roofing Tile: Comments: a Wood, Non - insulated New construction 19 / „” or greater plywood or wood plank. Mortar Set or Adhesive Set Application 2 ":12" to 7 ":12" Note: System D is only Acceptable in this slope range. Install underlayment system in compliance with Dade County Application Standard PA 120. (See System Limitation #S.) Install tile in compliance witl} Dade County Application Standard PA 120. (See "Data for Attachment Cal lulation&' included in this Approval.) 1. For re -roof applications, " /,i' plywood is an acceptable substrate. SYSTEMS (CONT1N1, ED) • Product Control No.: 96- 0318.02 u oaga _.... , ,..1.... - SYSTEM LIMITATIONS I! The standard minimum roof pitch for Ladrillera Santafes "Santafe S" high profile tile shall comply with Dade County Application Standards PA 118, PA 119 or PA 120, depending on the method of installation. 2: For nail -on applications, fasteners for mechanica attachment of tiles shall have a head diameter • larger than that of the preformed holes in the tile. System installation shall be in compliance with the system specifications outlined in this Product Control Approval. The method of attachment tilized shall provide a minimum characteristic resistance load greater than or equal to the require uplift resistance determined in compliance with Dade County Protocol PA 115 or PA 127. The Ladrillera Santafo "Santafe S" tile profile has been tested for static uplift performance only, there£ re, attachment calculations for installation in compliance with PA 115 or PA 127 shall be done a an 'Uplift Base System For mortar or adhesive set tile applications, a tie static uplift test by a Dade County accredited testing agency, in compliance with Dade County Protocol PA 106, shall be performed. 30/90 hot ma 5'. For mortar set tile applications, p ed underlayment applications may be installed perpendicular to the roof pitch unless stated othe ise by the underlayment material manufacturer's published literature. 6. All tiles shall bear the imprint or identifiable niarking of the manufacturer's name or logo for identification in the field. Applications for roofing permits shall include a! completed Section 11 of the Uniform Building Permit, a copy of Ladrillera Santafe's current specifications and details, a copy of this Product Control Approval and a copy of the Product Cont 01 Approval of any Roofing Component used in the proposed tile application. Reference shall b made to appropriate data for the required fire rating. j 5. The applicant shall retain the services .of a Dade County certified testing laboratory to maintain 1 quality control in compliance with the South Flori Building Code and related protocols. 9. Any amendments to these provisions shall be in compliance with Sections 203 and 204 of the South Florida Building Code. j i ' s l I Product Control No.: 96 Frank Zuloaga Plans Examiner. Product Control Div. 10/11/96; r'K.I 09:U9 k.0 305 3726339 • • Santafe S Clay Roof Tile ' Minimum 3" headlap. b 4.l.*J r U.VU..1 %/V0I1lV4.. DATA FOR ATTACHMENT CALCULATIONS Table 1: Average Weight (W) and Dimensions (ix w) Tile Profile Weight W (Ibf) Length • I (feet) Width w (feet) 0.98 6.60 ft Table 2; Min mum Charaeterlsttc Resistance Load - F' (Ibf) I' - Tile Tile Minimum Characteristic Two Approve Nails' Appilcati • n Resistance Load (lbf) m Profile Santafe S Clay Roof Tile Nail -0n Sy tem Sy tern One ApproveA Screw Mortar Set Adhesive :Set 1.50 Product Control No.: 96- 0318.02 31.00 26.50 33.60 85.10 The two nail holes shall be located at 2.5/16" and 2'! from the head and 2.5/8" and 2 -5/16" from the I interlock edge, respectively. 2 The screw hole shall be located at 2. 5/16" from the,head and 2 -5/16" from the interlock edge. • 5 • : • • PROFILE DRAWING I i IT LADRILLERA SANTAFt "SA AFt S" CLAY ROOP TILE Product Control No.: 96-018.02 Santafe Tile Corporation Ladrillera Santa.fe • Bogota; Columbia Product Control No.: 96- 0318.02 ACCEPTANCE NO.: 96 - 031$.02 APPROVED : Qctnher 10.1991 EXPIRES t October 10. 1999 1. Renewal of this Acceptance (approval) shall be onsidered after a renewal application has been filed and the original submitted documentation, including lest supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Dade County Product control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if a) There has been a change in the South F Building Code affecting the evaluation of this product and the product is not in ompliance with the code changes: b) The product Is no longer the same pro fluct (Identical) as the one originally approved: c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product d) The engineer who originally prepared signed and sealed the required documentation initially submitted , is no longer practicing the engineering profession. 4. Any revision or change In the materials, use' and/or manufacture of the product or process shall automatically be cause for terminatlon of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for re oval of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endo>lsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration date may be displayed in advertising iteratuie. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its d ?stributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer. 8. Failure to comply with any sectloty of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Acceptance contains pages 1 through 12. i • END OF THIS ACCEPTANCE 0 44# uloaga Plans Examiner, Product Control Div. 1 10.24.97 — VIA FAX AND OVERNIGHT MAIL Mr. Daniel Bernal Santafe Tile Corporation ,I 0302 NW South River Drive, Bay # 16 Medley, Florida 33178 rAX: (305) 888 -0050 Subject: Santafe Tiles as a Moment Based System Dear Daniel, As requested, we've completed an analysis of static uplift data for Santafe's mortar set, adhesive set and mechanically attached tile systems (Santafe S and Santafe Royal Low 5). The analysis entailed review of existing static uplift data, completed under Protocols PA 101 and PA 102 by the Center for Applied Engineering, and conversion of this data from I<Jplift Based System data to Moment Based System data. :This conversion is based on Toad placement at the time of Cesting and load placement criteria in the subject Metro -Dade Protocols. i . The subject CAE test reports are: Robert Mills for the Firm Exterior Research & Design, LLC Trinity Engineering Roofing and Waterproofing Consultants Roof Systems Analysis and Design Santafe S Tile: Royal Low S: Adhesive Set: Mortar Sec Nail On (one screw): Nail On (two nails) 94 -156 -2 94 -156 -1 • 25- 7205 -4A 25- 7205 -4B Adhesive Set: Mortar Sec Nail On (two nails) 4 Data generated in this analysis includes Restoring Moments Due To Gravity (Mg) and Attachment Resistance Expressed sp s A Moment (Mf). Analysis and results for each tile using each method of attachment are summarized on the attached readsheets. This static uplift data in conjunction with the aerodynamic multiplier data provided in my letter of 10.02.97 comprises all data necessary for analysis of Santafe S and Santafe Royal Low S tile, systems as Moment Based Systems. I have compiled this information on pages 2 of this letter for your convenience. Should you have any questions, kindly contact the writer. s ' Your sincerely, EXTERIOR RESEARCH & DESIGN, LLC. TRINITY ENGINEERING' 94-154-8 25- 7205 -1 94- 156.9 Colin Murphy, RRC 'Muff ;� Colin H R " �� Ms, "4 ,4' . " 'NS TIT',i l: Main Office: 1000 Lenora St. • Suite 401 • Seattle, WA • 98121 • Plxw 206-467-0054 • Fax: 206-467-5840 Laboratory: 600 West Nicke z n • Seattle, WA • 98119 Emaik ExDestrs@a utmn • Fed ID: 911691951 C: ldients I SANTEFE IPROJ,JS7111t 10249741 A i j /' • 'D'ATA FOR ATTACHMENT CALCULATIONS MOMENT BASED SYSTEM Santafe' S i Santafe Royal Low S Tile Profile ;Santafe S ;Royal Low S Tile Profile 5antafe S Royal Low S Tile Profile Table 2: Restoring Moment Due To Gravity — Mg «t.Ibf) 2:12 .3:12 : 4:12 5:12 4.9 4.8 : 4.7 4.6 5.1 ' 5.0 . 4.9 4.8 Table 3: Attachment Resistance Ex Two Approved One Approved Nails 21.8 14.2 w Table I: Aerod namic Multi lier ft� Nail -On, Direct beck Mortar or Adhesive Set 0.34 0.31 • 0.32 0.29 Screw ' 18.4 N/A 6:12 4.5 4.6 ressed as a Moment -. Mf (ft-lbf) Mortar • Set 23.6 . 48.6 Daniel Bernal — 10.24.97 Page - 2 7:12 4.4 4.5 Adhesive Set 61.9 89.0 MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Address Registered Architect and /or Engineer Name and address of licensed contractor___ Location and legal description of lot to be built on: Lot__--- _.._____ -_— Block Street and Number where work is to be done Zone cubage required_ STATE OF FLORIDA, COUNTY OF DADE. i ss ' Disapproved _ ( Signed) Building Inspector PLANN Subdivision k (Signed) Date No �, Street State work to be done and purpose of building (by floors). and for no other purpose. New Building____ ' Remodeling Addi. Repairs To be constructed of Kind of foundation Roof Covering Estimated Total cost of improvements $ _74 /�i' ___, - - -- Amount of Permit $ ___Plan Cubage No. o Stories Distance to next nearest building _Size of Building Lot Maximum live load to be borne by each floor • I hereby submit all the — ans and specifications for said building. All notices with reference to the building and its construction may be sent to______ The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5988, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection e site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such sub •: •ct w to be p rformed under this permit, as are licensed by Miami Shores Village. Remarks----___ Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the_ of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. —. r � c Permit No.____ /�_ �_____ __ Date S ----- ` "`�_ Read, Sworn to and Subscribed before me. Notary Public, State of Florida My Commission Expires BOARD DATE Chairman Member Member Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. BUILDING ELECTRICAL PLUMBING ROOFING Architect Contractor e ar Builder - > Owner of r'• "'i t! 1. Building CONTRACTOR OR BUILDER MIAMI SHORES VILLAGE, FLORIDA PERMIT Work to be performed under this Permit Legal Lot I Subdi- Description BI vision Address of • -/ r' ` F ( Value of .. r II Amount of Building _ / . < Project $ II Permit $ This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the applica- tion herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes respon- sibility for work done by his agents, servants or employees. ' f IA) i '' ' tZ::.7 1 • i . .,._ 't .,,, INSPECTOR Signed In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance th all ordinances std regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authoti s of Miami Shores Village. In as cepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. % / N9 7512 DATE Contractor's License No. r e• 1 w�. 191A1. r ( - BY AUTHORITY • oor " ''