ROOFINGLG ENGINEERING SERVICES, INC. Consulting Engineers North Office: 7370 N.W. 36ih Street Suite 374 Miami, Florida 33166 South Office: 13380 S.W. 131 Street Suite 120 Miami, Florida 33186 Tel: (305) 994 -8128 Fax: (305) 994 -8135 M. I. S Corporation 10221 Southwest 16`' Street Miami, Florida Project: Dear Sirs; TILL UPLIFT TEST Astreve Residence 258 Northeast 92 Street Miami, Florida Information provided by client: Permit Number: 45263 Date Completion: November 19, 1999 Roofing Contractor: M. I. S. Corporation. LG Engineering Services, Inc. Project Number: LG99 -1538 (Testing Laboratory Certificate #99- 0609.01) November 22, 1999 In accordance with your request and authorization, a representative of LG Engineering Services, Inc. completed the Roof Tile Uplift Test at the above referenced project. This testing was performed in general accordance with Roofing Application Standard RAS No.16 -- Standard procedure for field verification of the bonding of mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems. The total of the tested roof surface area was less than 5000 square feet, and the mean height of the roof is less than 20 feet above ground surface. The type of tile used for this project was reported to be Altusa Roof Tile. This tile was reported to have been foamed in place. At the time of this testing, one test for every corner, one test for every 100 square feet of roof tile in the perimeter area and one test for every 200 square feet of roof tile in the field area were tested. Initially the entire area of the roof was examined for loose tile. More than 10% of the roof tile located in the field area and more than 20 % of the roof tile at the roof perimeter and corner were physically examined. Based on our test results, we conclude that the installation of the roof tile at the above referenced project meets the test requirelinent outlined in the above mentioned protocol. Attached please find a copy of our test report for your review. LG Engineering Services, Inc. appreciates the opportunity of assisting you in this project. If you have any questions or if we may be of further assistance, please do not hesitate to contact the undersigned. Respectfully submitted; LG Engineering Services, Inc. TILE UPLIFLTEST Astreve Residence 258 Northeast 92 Street Miami, Florida ohamad Sonny Salleh P.E. Project Manager Test Number Test Load (lbf) Test Status 1 35 Pass 2 35 Pass 3 35 Pass 4 35 Pass 5 35 Pass 6 35 Pass 7 35 Pass 8 35 Pass 9 35 Pass 10 35 Pass 11 35 Pass 12 35 Pass 13 35 Pass 14 35 Pass 15 35 Pass 16 35 Pass 17 35 Pass 18 35 Pass 19 35 Pass 20 35 Pass 21 35 Pass 22 35 Pass 23 35 Pass 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Report of TILE UPLIFT TEST for Astreve Residence 258 Northeast 92 Street Miami, Florida Project Number: LG99 -1538 LG Engineering Services, Inc. -- Tile Uplift Test Result - Project Number: LG99 -1538 Page I Test Number Test Load (Ibf) Test Status . 24 35 Pass 25 35 Pass 26 35 Pass 27 35 Pass 28 35 Pass 29 35 Pass 30 35 Pass 31 35 Pass 32 35 Pass 33 35 Pass 34 35 Pass 35 35 Pass 36 35 Pass 37 35 Pass 38 35 Pass 39 35 Pass 40 35 Pass 41 35 Pass 42 35 Pass 43 35 Pass 44 35 Pass 45 35 Pass 46 35 Pass 47 35 Pass 48 35 Pass 49 35 Pass 50 35 Pass 51 35 Pass 52 35 Pass 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LG Engineering Services, Inc. -- Tile Uplift Test Result - Project Number: LG99 -1538 Page 2 Test Number Test Load (lbf) Test Status 53 35 Pass 54 35 Pass 55 35 Pass 56 35 Pass 57 35 Pass 58 35 Pass 59 35 Pass 60 35 Pass 61 35 Pass 62 35 Pass 63 35 Pass 64 35 Pass 65 35 Pass 66 35 Pass 67 35 Pass 68 35 Pass 69 35 Pass 70 35 Pass 71 35 Pass 72 35 Pass 73 35 Pass 74 35 Pass 75 35 Pass 76 35 Pass 77 35 Pass 78 35 Pass 79 35 Pass 90 35 Pass 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LG Engineering Services, Inc. -- Tile Uplift Test Result - Project Number: LG99 -1538 Page 3 North 75 d5 1 71 Approximate Test Location LG Engineering Services, Inc. -- Tile Uplift Test Result - Project Number: LG99 -1538 Page 4 q PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date , / </9' Job Address ISS L %` Tax Folio Legal Description Owner/Lessee / Tenant LC'(ZILQ.--\ Owner's Address o o " - Contracting Co. ,ZS Qualifier ! l v rlI r (3 t State # C CU C 0 U 4 Ma- Municipal # Architect/Engineer Bonding Company Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL Signature of o APPROVED: Zoning Mechanical FEES: PERMIT Historically Designated: Yes RADON a'-7? ZN 5aiv 7r Date c�G o . as o • er and/or Confident My Commission Expr'ie ry Public, State of Florida '�•� ORLANDO NUNEZ commission # '"!Ja Comm Expires es Ma 5 18, 2002 C.C.F. Phone No Master Permit # 9:5 -, 07/ 3 Address /0 2 t ) /' ST . /1/41( SS# - , Phone Competency # Ins. Co. Address Address OOHING ' AVING FENCE SIGN WORK DESCRIPTION �� l _ —�� �� ��� Square Ft. Q., 4cn Estimated Cost (value) WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY OF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. Notary as to Contractor o er- Builder My Commission Expires: ;;� ;,�,, Notary Public, State of Florida ' ,• `` ` = ORLANDO NUNEZ # CC 725791 • ' a ` Comm, Expires Mar. 18, 2002 NOTARY BOND TOTAL DUE ` / 1t s Building t Electrical Plumbing Structural Engineer if > NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION 998414 -590 1999 AUG 10 09: ',7 PERMIT NO. TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: IS 2. Description of improvement: `f \ \ 3. Owner(s) name and address: -_C Z1Q._.- • . t.� �,� �. � N■\ Interest in property: Name and address of fee simple titleholder: 4. Contractor's name and address: �2TS C �ff d r frT 7 °j " /0'22/ Sw / ST 5. Surety:(Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 6. Lender's name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: 4' 8. In addition to himself, Owner designates the following person(s) 10 receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: /11/d 9. Expiraton date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) Signature of Owner Print Owners Name ‘01Z1 Sworn to and subscribed before me this Notary Public Print Notary's Name r My Commission Ext i es: 'a.. 0 Commission # CC 725791 Comm. Expires Mar. 18, 2002 h T Cr nnIDA COUNTY ;,, 8Y CERTIFY tier this is a trre�tpy of the f' I e in f h s /�( W TNEcS n'y tAR E,t UVII d Of iciai seal. ER A D 9 Cir'uit nd County Courts D.C. • Prepared by: 41€Z, v L Address: , /cD Z / .S`&t. /4 5/ L 4A1/, / L ; 331 '3T 123 2/93 Ft •5 Contractor's Name: S C) irr rA4T O t.) ❑ New Roof DETAIL 1 & 2 *Includes Mortar a d Adhesive Set Tile Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. .Job Address: ROOF CATEGORY $Mortar-Set ❑ (Low Slope Application) ❑ (Nail-On Tile) Tire) * ❑ (Asphalt/Fiberglass Shingles) ❑ ( Metal Rno\Wood Shingles Bt Shakes) ❑ (Other) ROOF TYPE e- roofing ❑ Recovering ❑ Repair ❑ Maintenance Flat Roof Area (ft ___ _ Sloped Roof Area (ft 2 400 (ft2) 2 4004' Master Permit No. Exposure category (per ASCE 7 -88): Building Classification category (per ASCE 748 table 1): 7 ROOF REIGHT AND SYSTEM DETAILS (Draw details as needed) Page - 1 ROOF PLAN Deck type:' Appendix. "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. Ridge V m on? wANHEGar 12 N9- z Underiayment: Insaiadon: ROOFSLCUY DETAIL 3. - SLOPED SYSTEM DESCRIPTION Cap Sheet: Roof Covering: Page -2 Fastener type & spacingl 1 - CA-x ( 4 (? S_ /fti1 /c / ,4( 51 qd Drip edge ' 3 ff ,24 6,* ATTACHMENTS REQUIRED (u. 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) A pplicble Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals (Pmaxl: d c 3 x)1. (Aerodynamic Multiplier): • 7 (Pmax2: /° 2- X (Aerodynamic Multiplier): r 3 / (Pmax3: ° I 1- x X (Aerodynamic Multiplier): r / TIL ' CALCULATIONS ) _ .s __ _ = M i s l 7 -I PCA: ) - M:S- �J _ m . : .2 4. v PKA: ) - 1'( =Mr3 d PCA: APPENDIX "F "REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS As it pertains to this Appendix "F ", it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, to provide the owner with this appendix and to explain to the owner the content of this form. The provisions of Chapter 34 of the South Florida Building Code (SFBC) govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained. _ 1. Aesthetics - Workmanship: The workmanship provisions of Chapter 34 are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. /A 2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 29 of the SFBC. (The roof deck is usually concealed prior to removing the existing roof system) ,2 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. o f ,4 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The SFBC provides the option of maintaining this appearance. , Y 7 .9 5. Ponding Water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow Scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with Chapter 23 of the SFBC. .e 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. wner's /Agent's Signature Signature 5104 APPENDIX "F" 1 / e7 /2 Date Contractor's Signature � '7 4 t ETRO3 Almar (USA), Inc. 6645 Northwest 77th Avenue Miami, FL 33166 Your application for Product Approval of: Altusn Tile Nail -On, Mortar Set or APPROVED: 02 /13/97 1 METROPOLITAN DADE COUNTY. FLORIDA METRO -DAOE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 PRODUCT CONTROL NOTICE OF ACCEPTANCE FAX (305) 375.2906 e Piece "S" Tile Roofing Tile PRODUCT CONTROL DIVISION (305) 375.2902 FAX (305) 372 -6339 under Chapter 8 of the Metropolitan Dade ounry Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Redland Technologies, The Center for Applied Engineering, Inc. has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions set forth on pages 2 -16 and the standard conditions on page 17. This approval shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Building Code . Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compliance Oface reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. ACCEPTANCE NO.: 97- 0918.02 Renews 96-1030.03 EXPIRES: 02/13/00 Raul Rodriguez Product Control Division Supervisor THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County EipliMing Code Compliance Office and approved by the Building Code Committee to be us . in #ade County, F la under the conditions set forth above. y Charles Danger, P.E. Director Building Code Compliance Dept. Metropolitan Dade County Applicant: Altusa Tile ;Alrareria del Turbio, S.A. Barquisimeto, Venezuela Category: Prepared Roofing Sub-Category: Tile Type: Nail - on/Mortar Set! Sub- Tvpe,: Clay PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING S \'STEh1 APPROVAL Contact: Carlos 1. Fernandez General Manager Altusa Tile, Almdr (USA), Inc. 6645 Northwest 77th Avenue Miami, FL 33166 (305) 471 -5830 Product Control No.: 97 0918.02 Product Control No.: 97 0918.02 Approval Date: February 13, 1997 Expiration Date: February 13, 2000 Svstem Description Alfareria del Turbio, S.A. (Altusa), located in Barquisimeto, Venezuela, manufacturers clay roof tile for nail -on, mortar set or adhesive set applications. All tile is manufactured from natural Venezuelan clays. This Product Control Approval relates to Altusa's "Altusa S" tile profile. Refer to appropriate Product Control Approvals for other tile profiles. The "Altusa S" tile profile is available in a variety of natural clay colors and has matching trim pieces used for rake hip, ridge hip, and valley terminations. These accessories are manufactured for all profiles and form a part of this Product Control Approval. Optional rubber or clay eave closures are also available. Altusa roof tiles have been tested in compliance with the South Florida Building Code requirements for clay, nail -on, mortar set or adhesive set tile applications. The minimum roof slope for the "Altusa S" nail -on tiles shall be 2 ":12 ". See the "Profile Drawing" section in this approval for the "Altusa S" profile drawing. The "Altusa S" profile has been tested for both wind characteristics and static uplift performance. therefore, any consideration for installation shall be done as a 'Moment Based System'. Data for attachment calculations is noted in Tables I through 4 of this Approval. Aimar (USA), Inc., located in Miami, Florida, is the sole approved importer under contract for selling and distributing Altusa products in the South Florida jurisdiction. Frank Zuloaga P��n� FYiminer Product CnntrcI Division TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Test Product Dimensions Specifications Description 1= 18 '/ PA 112 Hiah profile clay roof tile for direct w = 10 'A" deck or battened nail -on, mortar or Y thick adhesive set applications. Head -lap min, 2 Exposure max. 16% :" I = varies w = varies Product Control No.: 97- 0918.02 PA 112 Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Frank Zuloaga Plans Examiner. Product Control Division ;43 Coated Base Sheet Mineral Surface Cap Sheet Rainproof II Ice and Water Shield Mopping Asphalt TRADE NAMES OF PRODUCTS MANUFACTURED OTHERS Dimensions N/A N/A N/A Lenzingtex -ZB 140 59" x 164' roll Underlayment 22 lbs /roll 30" x 75' roll 36" x 75' roll or 60" x 75' roll 36" x 75' roll N/A N/A Test Specifications ASTM D 226 type 11 ASTM D 7626 ASTM D 249 PA 104 PA 104 ASTM D312 type 111 or IV ASTM D 4586 4 Product Description Manufacturer Saturated organic felt generic to be used as a nailed anchor sheet. Saturated and coated organic base sheet for single or double ply underlayment. Mineral surfaced asphalt roll rooting for use as a top ply in a double ply underlayment system. Single ply, nail -on underlayment. Single ply, nail -on underlayment with 2" self - adhering top edge. PA 103 Self - adhering W.R. Grace Co. underlayment for use with current PCA as a top ply in a two ply underlayment system with Approved 430 or 443 as the base layer. Asphalt for bonding a mineral surface cap to a mech. attached base sheet in a double ply underlayment system. Cut back, asphalt based, asbestos free, fiber reinforced, trowel grade cement for repair and flashing applications. Product Control No.: 97- 0918.02 Frank Zuloaga Plans Examiner, Product Control Division generic generic Lenzing Performance, Inc. . with current PCA ' Protect -O -Wrap, Inc. with current PCA generic generic Asphalt Primer Wood Battens Test Product Dimensions Specifications Description ;Manufacturer NiA ASTM D 4I Cut back. asphalt generic based coating used to facilitate bonding of dissimilar materials. min. 12 ga. with ' /," head min. 32 ga. min. 1'4" o.d. max. 2" o.d. horizontal min. I" x 4" for use with vertical barrens or min. I" x 2" for use alone PA 114 Appendix E PA 114 Appendix E Annular ring shank, hot dipped, electro or mechanically gale. roofing nails for use in underlayment attachment. Corrosion resistant circular disc for use in underlayment attachment vertical Wood Preservers Salt pressure treated min. 1" x 4" Institute LP - 2 or decay resistant lumber battens Hurricane Clip & Clips PA 114 Corrosion resistant Fasteners min. '/ :" width Appendix E bronze, aluminum, min. 0.062" thick stainless steel, galvanized steel or Clp Fasteners plastic attachment min. 8d x I' /4" clips for supplemental tile attachment. Clips are installed with corrosion resistant roofing nails compatible with the clip. A hurricane dip is required on all nail -on eave tiles. Product Control No.: 97- 0918.02 generic generic generic generic Roof Tile Mortar N/A PA 123 Prepared mortar mix Bermuda Roof ( "TileTiteTM ") designed for mortar Company, Inc. set roof tile with current PCA applications. Product oar Tile Mort ( "Quikrete Roof 1 Tile Mortar "1140") Valley Flashing Dimensions N/A N/A min. 26 ga. min. 16" width min. 26 ga. min. 2" face flange min. 2" deck flange Test Product Specifications Description PA 123 Prepared mortar mix designed for mortar set roof tile applications. See PCA ASTM A 525 PA 11 Product Control No.: 97 -0918.02 Two component polyurethane adhesive designed for adhesive set roof tile appl ications. Galvanized steel generic valley flashing Galvanized steel drip generic edge Frank Zuloaga �~ Manufacturer Quikrete Construction Products with current PCA Polyfoam Products, Inc. with current PCA TEST REPORTS Produc: Control No.; 97- 0918.02 Test Agency Test 1 . e Test Name/Report Date Testwell Craig Laboratories Lab. #AAP -2 ASTMI 1 167 Oct. 1994 & Consultants, Inc. Redland Tccbnologics 7161 -03 Static Uplift Testing Dec. 1991 Appendix III PA 102 Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix 11 PA 108 (Nail -On) Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 PA 108 (Nail -On) Redland Technologies P0631 -0I Wind Tunnel Testing July 1994 PA 108 (Mortar Set) Redland Technologies PO402 Withdrawal Resistance Testing Sept. 1993 of screw vs. smooth shank nails Redland Technologies 7161 -03 Static Uplift Testing Dec. 1991 Appendix 111 PA 102(A) The Center for Applied 94 -83 Static Uplift Testing April 1994 Engineering, Inc. PA 101 (Adhesive Set) The Center for Applied 94 -084 Static Uplift Testing May 1994 Engineering. Inc. PA 101 (Mortar Set) The Center for Applied 25- 7200 -1 Static Uplift Testing Feb. 1995 Engineering, Inc. PA 102 (Quick -Drive Screws, Battens) The Center for Applied Project No. 307025 Wind Driven Rain Oct. 1994 Engineering, Inc. Test #MDC -78 PA 100 Frank Zuloaga Plans Examiner. Product Control Division Deck Type: Deck Description: SYSTEM D: Slope Range: Undcrlavment: Roofing Tile: Comments: Wood, Non - insulated New construction i /,," or greater plywood or wood plank. SYSTEMS (CONTINUED) Mortar o Adhesive Set Applicati Product Control No.. 97 - 0918.02 2 ":1 to 7":12" Note: System D is only acceptable in this slope range. For slopes in excess of 7 ":12 ", refer to System C. Install underlayment system in compliance with Dade County Application Standard PA 120. (See System Limitation #5.) Install tile in compliance with Dade County Application Standard PA 120. (See "Data for Attachment Calculations" included in this Approval.) 1. For re -roof applications, "/ plywood is an acceptable substrate. Frank Zuloaga r n 1 n' PROFILE DRAWING ALTUSA "S" CLAY ROOF TILE ACCESSORIES 10-1/' 2" GOvG SAN. LOCKS 13 Product Control No.: 97- 0918.02 Frank Zuloaga P1��� FY1minrr Product Control Division PROFILE DRAWING APPROVED SCREW Product Control No.: 97 - 0918.02 Frank Zuloaga Plans Examiner Product Control Division Table 2: Restoring Moments due to Gravity - M (ft -Ibf) from PA 102 Testing Tile Profile . 3 " :12" or less 4 ":12" 5 ":12" 6 ":12" 7 ":12" or greater Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Altusa 'S' Tile 4.47 5.35 4.40 5.27 4.31 5.18 4.20 5.03 4.08 N/A Tile Profile Table 4: Attachment Resistance Expressed as a Moment - M (ft-Ibf) from PA 101 Testing X (ft') Direct Deck A.plication Tile Profile Tile Application Attachment Resistance Altusa 'S' Tile 1 nail Mortar Set 24.50 Adhesive Set 66.50 Tile Profile A. (ft') Batten Application X (ft') Direct Deck A.plication Altusa 'S' Tile 0.29 0.31 Table 3: Attachment Resistance Expressed as a Moment - Mr (ft -Ibf) from PA 102 and PA 102(A) Testing Tile Profile TILE APPLICATION APPROVED NAILS APPROVED' SCREWS APPROVED FIELD CLIP WITH: APPROVED EAVES CLIP WITH: 1 nail 2 nails 1 screw 2 screws 1 nail 2 nails 1 nail 2 nails — !Altusa 'S' Tile Battens N/A N/A N/A 26.80 N/A N/A N/A N/A Direct Deck 8.20 8.40 28.70 58.20 21.20 25.30 26.90 34.90 DATA FOR ATTACHMENT CALCULATIONS Table 1: Aerodynamic Multipliers - (ft') Product Control `'o.: 97- 0918.02 ' 1. Quik•Drive screws installed in two manufactured holes located 1 and 1 ° /e" from the head of the tie. Frank Zuloaga Ptnns Fviminer Pr..rlurr f'nntrnl fivisinn BIRD STOP NAIL HOLE NAIL HOLE --- 14 Product Control No.: 97 - 0918.02 GABLE-RAKE .0111W ran uloaga pb�� FYirrin'r Prr.}nrt ('nntrnl Nvision SYSTEM LIMITATION'S Product Control No.: 97- 0913.02 I The standard minimum roof pitch for Altusa "S" high profile tile shall comply withDade County Application Standards PA 1 18, PA 119 or PA 120. depending on the method of installation. 2. For nail - on applications, fasteners for mechanical attachment of tiles shall have a head diameter larger than that of the preformed holes in the tile. 3. System installation shall be in compliance with the system specifications outlined in this Product Control Approval. The method of attachment utilized shall provide sufficient attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with Dade County Protocol PA 115 or PA 127. Altusa "S" tile profile has been tested for both wind characteristics and static uplift performance, therefore, attachment calculationsfor installation in compliance with PA 115 or PA 127 shall be done as a 'Moment Based System'. For mortar or adhesive set tile applications, a field static uplift test by a Dade County accredited testing agency, in compliance with Dade County Protocol PA 106, shall be performed. 5. For mortar set tile applications, 30/90 hot mopped underlayment applications may be installed perpendicular to the roof pitch unless stated otherwise by the underlayment material manufacturer's published literature. 6 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo for identification in the field. 7. Applications for roofing permits shall include a completed Sectionll of the Uniform Building Permit, a copy of Almar USA's current specifications and details, a copy of this Product Control Approval and a copy of the Product Control Approval of any Roofing Component used in the proposed tile application. Reference shall be made to appropriate data for the required fire rating. 8. The applicant shall retain the services of a Dade County certified testing laboratory to maintain quality control in compliance with the South Florida Building Code and related protocols. Samples taken shall be in compliance with Dade County Protocol PA 112, Appendix 'A'. Frank Zuloaga Pllnc FY3minrr Product Control Division Product Control No.: 97 - 0913.02 Tfl FAI Altusa Tile, Almar (USA), Inc. 6645 Northwest 77th Avenue. Miami Fl 33166 . ACCEPTANCE NO.: 97- 0918.02 APPROVED : February 13, 1997 EXPIRES : Fcbruary 13.2000 NOTICE OF ACCEPTANCE STANDARD CONDITIONS 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement; "Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted , is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Acceptance contains pages 1 through 17. END OF THIS ACCEPTANCE 17 Tel T r -i,. T- ; r. Fran Zuloaga Plans Examiner, Product Control Division • ^ r • PRODUCT CONTROL NOTICE OF ACCEPTANCE Polyfoaln Products, Inc. 2400 Spring- Sttlebner Road Spring, TX. 77333 Your application for Product Approval of: Polvfoam Products "Polvpro AH -160" Ronf Tile Adhesive under Chapter 8 of the Miami -Dade County Cods: governing the use of Alternate Materials and Types of Construction, and completely described in the plans. specifications and calculations as submitted by: The Center for Applied Engineering, Inc. and Miles Laboratories Polymers Division has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County. Florida under the specific conditions set forth on pages 2 -14 and thc standard conditions on page 15. This approval shall not be valid after the expiratiun date stated below. The Building Code Compliance Office reserves thc right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. I f this product or material rails to perform in the approved manner, the Building Code Compliance Office may revoke. modify, or suspend the use of such product or material immediately. The Building Code Compliance Office reserves thc right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. ACCEPTANCE NO.: 98- 0303.02 Renews: 96- 0402.02 EXPIRES: 04/16/01 THIS IS TITF. COVERSIIF..F.T, SEE ADDI'T'IONAL PAGES FOR SPECIFIC AND GENERA', CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Miami•Dadc County Building Codc Compliance Ofice and approved by the Building Cede Cotntt :lace to be used in Dade County. Florida under the conditions set forth above. A I'I'RO V E D: 04/1.6/98 1 Internet malt address: po $tmaeler @buildingcodeonlIne.com OPP 7a •eq tt:dt METROPOLITAN DADE COUNTY. FLORIDA METRO -OAOE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO•OAOE FLAGLER BUILDING 140 WEST FLAGLER STREET. SUITE 1603 MIAMI. FLORIDA 33130 -1563 (305) 375.2901 FAX (305) 3'15 -2908 PRODUCT CONTROL DIVISION (305) 375-2902 FAX (305) 372-6339 aul Rodriguez Product Control Supervisor LAT, j Charles Danger. P.E. Director Building Codc Compliance Dept. Miami -Dade County Momepage: http : //www.buildingcodeonitne.corn 954 475 1 4 5 2 ! G ! . 2 Apr -29 -98 11 :39A Polyfoam Products Inc. POLYFOAM PRODUCTS, INC. Applicant: Polyfoam Products, Inc. 2400 Spring - Stucbner Road Spring, Tcxas 77383-1132 Category: Roofing Component Sub- Category: Fastening/Adhesive ape: Roof Tile Adhesive Sub -Type: Two Component Polyurethane PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING COMPONENT APPROVAL. System Description Polyfoam Products, Inc., produces two- component expanding polyurethane adhesive for the attachment of clay and concrete roof tile. Polypro® A1-1160 is specially designed fur application of concrete and clay roof tile over a variety of roof deck substrates and underlayment materials. Polypro® adhesive is applied with proprietary Foampro® RTFI000 dispensing equipment. Approval of this product is specific to the two component mix and Foampro® RTF1000 dispensing equipment. Alternative methods of dispensing will require a revision to this approval. Polypro® adhesive shall be applied only by 'Qualified Applicators', licensed by Polyfoam Products. Inc. Certificates and identification cards arc issued to applicators upon successful completion of a application training program. Approval of this adhesive system is contingent upon application by a 'Qualified Applicator. Contact: Pat Murray P.O. Box 1132 Spring, Texas 77383-1132 Phone: (713)350 -8888 Fax: (713)28R-6450 Page 2 of 15 954 475 -1462 Product Control No.: 98- 0303.02 Product Control No.: 98-0303.02 Approval Datc: April 16, 1998 Expiration Date: April 16, 2001 Frank Zuloaga. RRC Roofing Product Control Examiner P.03 Apr -2 -98 11:39A Polyfoam Products Inc. 954 475 -1462 P.04 • . POLYFOAM PRODUCTS. INC. Product Control No.: 98- 0303.02 Product Polypro0 A11160 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Foampro® RTFI000 N/A See Detail Attached Dispensing Equipment Test Product Dimensions Specifications Description N/A PA 101 Two component polyurethane Page 3 of 15 Frank Zuloaga, RRC Roofing Product Control Examiner Apr -29 -98 11:39A Polyfoam Products Inc. • • POLYFOAM PRODUCTS, INC. Product Underlayment Roof Tile Test Criteria PA 101 Page 4 of 15 Product Dcscription 954 475 -1462 Product Control No.. 98- 0303.02 TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS PA 120 All Dade County Component Approved products as detailed in Dadc County Application Standard PA 120 All Approved roof tile systems having tested in compliance with Dade County Protocol PA 101, as detailed in the systems section of this Component Approval Manufacturer. All Dade County Approved Products All Dadc County Approved Products rank Zuloaga, RRC Roofing Product Control Examiner P.05 Apr -29 -98 11:40A Polyfoam Products Inc. TEST REPORTS Test Agency 954 475 -1462 P.06 • POLYFOAM PRODUCTS, INC. Product Control No.: 98- 0303.02 Test Identifier Test Name/Report Date Center for Applied #94 -060 Miami Dade Protocol 04/03/94 Engineering PA 101 Center for Applied 257818 -IPA Miami Dade Protocol 12/16/96 Engineering PA 101 Center for Applied 25- 7438 -3 SSTD 11-93 10/25/95 Engineering Center for Applied 25- 7438 -4 SSTD 11-93 10/25/95 Engineering Center for Applied 25- 7438 -7 SSTD 11 -93 11/02/95 Engineering Center for Applied 25 -7492 SSTD 11-93 12/12/95 Engineering Miles Laboratories NB- 589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, 9637 -92 ASTM E 108 04/30/93 Inc. Southwest Research 01- 6743 -011 ASTM E 108 1 1/16/94 Institute Southwest Research 01-6739-06213[1j ASTM E 84 01/16/95 Institute Trinity Engineering 7050.02.96 -1 PA 114 03/14/96 Page 5 of 15 Frank Zuloaga, RRC Roofing Product Control Examiner Apr -29 -98 11:40A Polyfoam Products Inc. . POLYFOAM PRODUCTS, INC. Product Control No.: 98- 0303.02 TYPICAL PHYSICAL PROPERTIES Pronerty Ii Density ASTM D 1622 1.6 Ihs. /ft.' Compressive ASTM D 1621 18 PSI Parallel to rise Strength 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 l.bs. /Ft Moisture Vapor ASTM E 96 3.1 Perm / Inch Transmission Dimensional Stability Closed Cell — Content ASTM D 2126 ASTM D 2856 86% 954 475 -1462 P.07 Results +0.07% Volume Change -40 F., 2 weeks +6.0% Volume Change 0158°F.. 100% Humidity, 2 weeks Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variatiun. Page 6 of 15 Frank Zuloaga, RRC Roofing Product Control Examiner Apr -29 - 98 11:40A Polyfoam Products Inc. . ' POLYFOAM PRODUCTS, INC. Product Control No.: 98 - 0303,02 Deck Type: Wood, N on- insulated, New Construction /Reroof Deck Description: 15/32" or greater, plywood or wood plank. SYSTEM A: Adhesive Set Application Slope Range: 2 ":12" to 7 ":12" Underlayment: Shall comply with Miami - Dade Roofing Application Standard PA 120 Roofing Tile: Any roof tile assembly having a current shall be applied in compliance with the Component Application scction and the corresponding Placement Details of this Notice of Acceptance. The adhesive attachment shall provide sufficient attachment rcsistancc expressed as a moment to meet or exceed the required moment of resistance determined in compliance with Miami-Dade County Roofing Application Standards PA 115 or PA 127. The adhesive attachment data is noted in the roof tile assembly NOA. SYSTEMS Comments: 1. All 'System Limitations' noted in the tile Roof System Assembly Product Control Approval shall apply. I'age 7 of 15 954 475 -1462 P.08 Frank Zuloaga, RRC Rooting Product Control Examiner Apr -29 -98 11:40A Polyfoam Products Inc. POLYFOAM PRODUCTS, 1 Product Control No.: 9S- 0303.02 SYSTEMS (CUNTTNUF.D) 954 475 -1462 P.09 Deck Type: Concrete, New Construction /Rcrouf Deck Description: New construction SYSTEM 13: Adhesive Set Application Slope Range: 2":12" to 7":12" Undcrlaymcnt / Install Approved underlay/nent system of one of the following: Waterproofing: Underlayment: (30/90 Hot Mop) fully adhered in a full mopping of ASTM D 312 type I V asphalt applicd within the ENT range. Back nailing and laps shall be in compliance with Rooting Application Standard PA 120. Roofing Tile: Comments: Any liquid applied roofing system having a current NOA for its use as a tile underlaymcnt system. Any roof tile assembly having a current shall be applicd in compliance with the Component Application section and the corresponding Placement Details of this Notice of Acceptance. The adhesive attachment shall provide sufficient attachment resistance expressed as a moment to meet or exceed the required moment or resistance determined in compliance with Miami -Dade County Roofing Application Standards PA 115 or PA 127. The adhesive attachment data is noted in the roof tile assembly NOA. 1. All 'System Limitations' noted in the tile Roof System Assembly Product Control Approval or waterproofing component Roofing Component Product Control Approval shall apply, as applicable. Page 8 of 15 Frank Zuloaga, RRC Roofing Product Control Examiner Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Two -Piece Barrel #1 'S' Shaped #2 Double Roll #3 Flat # Apr -29 - 98 11:41A Polyfoam Products Inc. . POLYFOAM PRODUCTS, INC. Product Control No.: 98- 0303.02 COMPONENT APPLICATION 1 Polypro® Al [160 tile adhesive shall only be applied over an underlaymcnt installed in compliance with application instructions detailed in its NOA.. Underlayment may be any underlayrnents or underlayment systems listed Miami -Dade County Roofing Application Standard PA 120. 2. Adhesive application shall be in accordance with the instructions provided herein. Tthe manufacturer may provide additional instructions subsequent to this approval date which may prevail. Installation must he by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. 3. Calibration of the Foampro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "A" component shall be maintained between 1.0- 1.15 (A) : 1.0 (B). The dispense timer shall be set to deliver 0.08 to 0.15 pounds per tilt as determined at calibration. No other settings shall be approved without revision of NOA. 4. Adhesive shall be dispensed in a 17 in' to 23 in' pad at time of application. The cured pad shall be approximately 5" x 12 ". Foam placement shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires a specific placement. as noted in Table 1, below 5. Adhere tilt dircctly.in freshly applied adhesive. Tile must be sct within 2 to 3 minutes after foam has been dispensed. Page 9 of 15 954 475 -1462 P.1O Frank Zuloaga, RRC Roofing Product Control Examiner r cr'r_c ra, ct_ Z Apr -29 -98 11:41A Polyfoam Products Inc. SYSTEM LIMITATIONS Page 10 of 15 954 475 -1462 P.11 • POLYFOAM PRODUCTS, TNC. Product Control No.: 98- 0303.02 2. Polypro® A1[160 adhesive shall be installed only by 'Qualified Applicators' approved and licensed by Polyfoam Products, Inc. 3. For adhesive set tile applications, a field static uplift test by a Miami -Dade County accredited testing agency, in compliance with Miami -Dade County Roofing Application Standard PA 106, shall be required not less than 72 hours after application to confirm tile adhesion. 4. Refer to application drawings published by the National Tile Manufacturers Association for penetrations and terminations, as well as the 'Placement Details' included with NOA. 5. Refer to tile Root Assembly Product Control NOA for system acceptance with this Component. 6. Refer to the Prepared Roof Tile Assembly for fire rating. 7, Polypro® AH 160 shall not be exposed permanently to sunlight. 8. Polypro® A14160 shall be applied with Foampro RTF1000 dispensing equipment only. 9. Polyfoam ProductsTne. shall supply Building Official with a list of 'Qualified Applicators' approved and licensed by Polyfoam Products, Inc. Frank Zuloaga, RRC Roofing Product Control Examiner t •, 1 Apr -29 -98 11:41A Polyfoam Products Inc. POLYFOAM PRODUCTS, INC. U wMr l.tm. 2) 7 .w.. .w... .o..1f. dew. • 1... A.a`1.. 1/r 1. 1" tws U. d. ..Ip..1 ....r 111.. Thom .w. /tll ta.. 1 )•1w...w..mA .IA..1.. I. .e Ai.w 17 to 27 .o. iw. Awe Iw ..wt..t ..11h the pow ell.. R..w... I. porno. of U.. .... oaru. dl.. Att..t to ....wa ...... pow 1(1.o. !wow. .... .w. M Owl wet ••••• than .r. It■A 01 moo. Iiw.. 1....I..... (mortal. .Mw. PLACEMENT DETAILS Moll throw. p1..Ut Powwow' 954 475 -1462 P.12 Product Control No.: 913- 0303 OW* ommilcoll...L. -�' ,/ • Placement Detail NI: Two -Piece Barrel Profile Pagc 11 of 15 I..mlt •.er4 berme require/ by seq.) Optlwol ►mlwWp an or .•. 1 ...olt.rlw.1 of en.. I A..U I.. Frank Zuloaga, RRC Roofing Product Control Examiner Apr -29 -98 11:41A Polyfoam Products Inc. POIXFOAM PRODUCTS, INC. Moll 1IVwyA pI..11..-•w -..l (..1.... •••*••• ny s.4.t PLACF.MENT DETAILS (CONTINUED) u.a..i- y•■•••■ Page 12 of 15 AMy ..w.., Mil--I-- l- --•lo••• 17 1. >n .M•- Iw.A-- 1. --r-.-- •.MA (A- tll., Placement Detail 112: 'S' Shaped Tile Profile 954 475 - 1462 P.13 Product Control No.: 9S- 0303.02 D•ly !Igo Frank Zuloaga, RRC Roofing Product Control Examiner • • • Apr -29 -98 11:41A Polyfoam Products Inc_ POLYFOAM PRODUCTS, INC_ N.Y IM..gh p1..11...w.w1 I�hw. r.QWrr/ try *1.60 1... Corm. PLACEMENT DETAILS (CONTINUED) 4.. w....Jy. Lr� ....1.. A.Vr.d...11.V bow la+.pl..iw. Page 13 of 15 ..hi... 17.21 .�....� I...1... 1...wh1 .AM 1h. 111. Placement Detail t13: Double Roll Profile 954 475 -1462 P.14 Product Control No,.: 98- 0303.02 WV. CI..r.. Frank Zuloaga, RRC Roofing Product Control Examiner Date Legal Description Owner / Lessee / Tenant 46c %r Master Permit # Owner's Address 25 7 J Phone 77-� 766C Contracting Co. /- 1 ( 41 Address 72-57,x/6 2 Qualifier / ? / 7 . 7.- SS# Phone 7'�- 3?Zi State 494/0247.1 municipal # Competency # K8/ Ins .Co. Architect /Engineer Address Bonding Company Address Mortgagor Address Permit Type(circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL 'OOFING PAVING PENCE SIGN WORK DESCRIPTION ��°�i�� ' / / / /e , Or Square Ft. ® Estimated Cost(value) ,222 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.: OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all'wosk will be don- in compliance w all applicable laws regulating co' ruc io and zon Fur hermor'e, I authojze the above-nad co • tr: ctor- -to" do the work stated ! / - W i t / #401Lik # _, ■/>, .,,,/ r /or Condo President Q ntr,ct'. r Own-- owne o Da . y :� � " OFFICIAL. SEAL" . T , , /�[. S , � r Alfred McKnight % �, '� /� , ,� � ` , ; o ,? My Commis f es $/31/ Nota as to Own 6 dgmki �i�� et1227G "stractor or Owner - Builder` y Con otary as t• My I.mmission Expires': " " ' ** * * * * P'° FEES: PERMIT ? �, RADON C.C.F. APPROVED: Zoning PERMIT APPLICATION FOR MIAMI SHORES VILLAGE C/ Job Address 2.-g /A'r 5 ;7 2 4:=5/ 4 71- C 4 "' s Tax Folio * * * * Fire Bui Mechanical Plumbing uilder Sign Dat My Commission Expires: 111 Other Electrical Engineering