WS-09-2022 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: I NSP- 144917 Permit Number: WS -12-09 -2022 Scheduled Inspection Date: June 02, 2010 Permit Type: Windows /Shutters Inspector: Bruhn, Norman Inspection Type: Final Owner: CARINO, SALVATORE Work Classification: Door Replacement Job Address: 290 NE 93 Street Miami Shores, FL Phone Number Parcel Number 1132060133480 Project: <NONE> Contractor: ADCO OVERHEAD GARAGE DOOR IN Building Department Comments GARAGE DOOR REPLACEMENT Inspector Comments Passed �& r Failed � Correction I ❑ Needed 1 , Re- Inspection Fe e No Additional Inspections can be scheduled until re- inspection fee is paid. June 01, 2010 For Inspections please call: (305)762 -4949 Page 18 of 18 Miami Shores Village ` f= 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 - 2204, 3 � Expiration: 71201 Project Address Parcel Number Applicant 290 93 Street 1132060133480 Miami Shores, FL Block: Lot: SALVATORE CARINO Owner Information Address Phone Cell SALVATORE CARINO 290 93 Street MIAMI SHORES FL 33138 -2827 Contractor(s) Phone Cell Phone Valuation: $ 1,300.00 ADCO OVERHEAD GARAGE DOOR IN Total Sq Feet: 0 Type of Work: GARAGE DOOR For Inspections please call: No of Openings: 1 (305)762 -4949 Additional Info: IMPACT Available inspections: Classification: Residential Inspection Type: Fees Due Amount Invoice # Total Amt Paid Amt Due CCF $ WS -12 -09 -36603 $ 122.20 $ 50.00 ¢ Education Surcharge $0.40 z Permit Fee $110.00 WS - 09 - 36603 $ 122.20 $ 122.20 $ 0.00 Scanning Fee $9.00 Submittal Fee $50.00 Submittal Reversal Fee ($50.00) Technology Fee $1.60 Total: $122.20 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT. I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. December 14, 2009 Authorized Signature: Owner / Applicant / Contractor / Agent Date Building Department Copy December 14, 2009 1 O WN 0.1 '•.: t,J:Lt P �S'•! '' � 1, „ i ,��y r + {I "�.,tj�r�irU' =A ^ ji. I 'I W.. �q' , �'J <..: • , } .e'� •�t ,:.%:�r :''ai33•...5:; " '': .t» ! .h„ t JvJ ''� M L /k� • .d s� 5 ;f'.: k., 'fl:.'° J.f it.. M A - V44 MAY `.A t+t' �1J!9 tW, ! t ' .::(;i,.py94it::1. 4 :.'•e'rv: tN. , �9,;� , 5 . •5y4•,4» .. �: �. p � .,t • t. ; v. .... • ' .. f 1, .,� . . . ........ 'Q9 .e1�''s��,�'N TW W. r. DO NOT FORWARD ADCO OVERHEAD GARAGE DOOR INC HUMBERTO FERNANDEZ PRES 7577 NW 50 ST MIAMI FL 33166 . .� s',; I III I Mill 1111111111611111 t1hki III) it HIL III! killiltill SEE OTHER SIDE `'•5. C::::nftl 4p `•,� 1 gg m . ir. w . 4 -31 gill ' -op up �'M 4: X: I A A " � ' w "J. ,wv g # px7 K u • ,r 'g- 05 0-1 1 , .10 .1. R ASP, g6g ........... . . . . . UM MRA )o NOT FORWARD ADCO OVERHEAD GARAGE DOOR INC HUMBERTO FERNANDEZ PRES ?;:��1 x P1 7577 NW 50 ST MIAMI FL 33166 0.1 TO'd xyl MUM JR xa9o:zo to/o?/co I Miami Shores Village Building De g artment p 100510 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: 305 795.22,04 Fax: 305 75 Tel: ( 305) ( 6.8972 I I� BUILDING �" Permit No. PERMIT APPLICATION Master Permit No. FBC 200 1 Permit'Fyper I II 'I Owner's Name (Fee Simple Titleholder) �{ Ly CAej y -,-o Phone# Owner's Address O 1\1 "ED S City S1�t(C.ES State Zip -331 38 Tenant/Lessee Name Phone # E -MAIL: e i he innr L� coL-n Job Address (where the work is being done) .` $ 9 E City Miami Shores Village County Miami -Dade Zip 33 ! Z FOLIO / PARCEL # 1 " a - 0 Cxv 3 3 3�F v I,II Is Building Historically Designated YES NO Contractor's Company Name "s C,c�) 1J (� P Y V one O t3 Contractor's Address . City State Zip __ Qualifier Name 1•t..� Phon # State Certificate or Registration No. Certificate of Competency No. E -MAIL: ADCo YAM,6 GnrY/ Architect/Engineer's Name (if applicable) Phone # �i Value of Work For this Permit $ , t� Square/ Linear Footage Of Work: Type of Work: E❑Addition ❑Alteration iew Repair /Replace ❑ Demolition Describe Work: DI.Ael= WfjbQF_ G8gA�j& D06 1, II y � - �� � Submittal Fee $ —'Vu' yu Permit FeO $ 11 + CCF $ 1 CO /CC Notary $ . Training /Educatiof Fee $ Technology Fee . $ 1 -: .. gY Scanning Radon $ DPBR $ Zoning $ Bond $ Code Enforcement ro $ Double Fee $ Structural Review. $ Total_Fm Now Due $ See Reverse side -� Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lenders Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated [ .certify`tMt Ark or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the stan&a.. ,"off - laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELEe -TRWAL WORK;' PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO O$TAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEM'ENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant, must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven 7) days after the permit is issued In the absence of such posted notice, the inspection will not be ap ved and a nspe Lion fee will be charged Signature Signa Owner Agent on for f A The foregoing. instrument was acknowledged before me this The foregoing instrument w acknowl dged before me this day of /1 a 1' , 20 p_, by < ShU k) day of , 2� , by T , _who is personally known to me or who has produced T 4—A-11 who i personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: T�� DA uErz' � -� � NOTARY PUBLIC: 650- 38a. 351 - o� e�P• �o• 31. 2orz. Sign Sig • c ^�' : C. Print: �'ISZ� Print: A on #DD8 1 My Commis ii t ?mission #DD61$548 My Commission Ex ;. Exp1m: AUG. 04, 2017 c'y ;� 03 201 R, , �VL �ti3tiA�i 'ib��y1P14.'�x &xxx9ex4:et� &xY daxicxxxaY sk �'eYxa°YxeY 9exxdexY eYdcxeYxYx��+o':l�+P.,a"S�SY .ex �x drx Ye Y4ea� dcxrxx 'xxxxeY' APPLICATION APPROVED BY: /� Plans ExaEniner Engineer Zoning (R&ised•02 /0.8/06) q � Do v V � s a W A `, VU M,ai7 Shores APPI[POVED BY ZONING DEPT RI_ Dr; DEPT" S ",;EJECT TO COMPLIANCE WITH ALL FEDERAL TATE AND COUNTY RULES AND REGULATIONS 0 WORST CASE DESIGN PRESSURE CHART RETROFIT GARAGE DOOR mc 146 MPH, EXPOSURE C BU LUNG : DADE CO. FLORIDA a CMYpwW 2007 FLORIDA BUILDING CODE (ASCE7) THE CHARTS BELOW ARE DETERMINED FOR THE WORST CASE SCENERIO, BASED ON THE FOLLOWING ASSUMPTIONS: : "• 0000•• 1) THE ENTIRE GARAGE DOOR OPENING IS ASSUMED TO BE IN THE END ZONE (ZONE:i V 0• • • 0000•• • •• 0000• ACCORDING TO ASCE7 CALCULATION METHODS. V • • 2) BASED ON ENCLOSED BUILDING, ANY ROOF SLOPE. ' • • ' 0000•• 0000•• 3) STANDARD APPLICATION (IMPORTANCE FACTOR = 1.00) 0000 0000 • ' NOTE 1: SPECIFIC, INDIVIDUAL GARAGE DOOR OPENINGS WILL MOST LIKELY NOT ' �••••• ••••• REQUIRE THE OPENING TO BE COMPLETELY IN ZONE 5 BY CALCULATION. 0000•• •• 0 " "' THEREFORE INDIVIDUAL CALCULATIONS WILL MOST LIKELY RESULT IN LOWEP6• • 00 • •••••• • NEGATIVE DESIGN PRESSURES THAN SHOWN ON THESE CHARTS. 0000•• • ' • NOTE 2: DOORS LARGER THAN THOSE LISTED MAY USE THE DESIGN PRESSURE FOR THE: • • 00 00 0.00.0 NEXT SMALLEST DOOR BECAUSE DESIGN PRESSURE DECREASES AS OPENING SICE X00 0000 :0900: INCREASES. FOR EXAMPLE, A 16'x10' OPENING CAN BE ASSUMED TO HAVE •• ' 0 00 0 0 0 THE SAME DESIGN PRESSURE AS A 16'x8' OPENING BECAUSE ACTUAL 0000 CALCULATIONS WILL SHOW THE 16'x10' TO HAVE A LOWER DESIGN PRESSURE. WORST CASE DESIGN PRESSURES (PSF) MEAN ROOF HEIGHT UP 5' 16' 17' 18' 19' 20' 8 41.3 - 1. +41.8 -52.5 +42.3 -53.1 +42.8 -53.7 +43.3 -54.3 +43.7 -54.9 N 8'x8' +40.9, -51.1 +41.4 -51.7 +41.9 -52.3 +42.4 -52.9 +42.8 -53.5 +43.3 -54.1 V3 9'x7' +41.0 -51.2 +41.4 -51.8 +41.9 -52.4 +42.4 -53.0 +42.9 -53.6 +43.4 -54.2 0 9'x8' +40.6, -50.4 +41.0 -50.9 +41.5 -51.5 +42.0 -52.1 +42.5 -52.7 +42.9 -53.3 z 16'x7' +39.2 -47.7 +39.7 -48.2 +40.1 -48.8 +40.6 -49.4 +41.1 -49.9 +41.5 -50.5 Lu a 16'x8' +38.8 -46.9 +39.3 -47.4 +39.7 -48.0 +40.2 -48.5 +40.6 -49.1 +41.1 -49.6 0 18'x7' +38.9, -47.0 +39.3 -47.5 +39.8 -48.1 +40.2 -48.6 +40.7 -49.2 +41.1 -49.7 18'x8' +38.5, -46.2 +38.9, -46.7 +39.4, -47.3 +39.8, -47.8 +40.3, -48.3 +40.7, -48.9 WORST CASE DESIGN PRESSURES (PSF) MEAN ROOF HEIGHT 21' 22' 23' 24' 25' 8'x7' +44.1 -55.4 +44.5 -55.9 +44.9, -56.4 +45.3 -56.9 +45.7 -57.4 N 8'x8' +43.7 -54.6 +44.1 -55.0 +44.5 -55.5 +44.9 -56.0 +45.2 -56.5 55 9'x7' +43.8 -54.7 +44.1 -55.1 +44.5 -55.6 +44.9 -56.1 +45.3 -56.6 0 9 +43.3 -53.8 +43.7 -54.3 +44.1 -54.7 +44.5 -55.2 +44.8 -55.7 z 16'x7' +41.9 -50.9 +42.3 +42.6 +43.0 -52.3 +43.4 -52.7 Lu a 16'x8' +41.5 -50.1 +41.$ -50.5 +42.2 -51.0 +42.6 -51.4 +42.9 -51.8 O 18'x7' +41.5 -50.2 +41.9 -50.6 +42.2 -51.1 +42.6 -51.5 +43.0 -51.9 18'x8' +41.1, -49.3 +41.4, -49.8 +41.8, -50.2 +42.2, -50.6 +42.5, -51.1 THIS CALCU TION SHEET IS ONLY VALID FOR THE FOLLOWO MG RANDS: CLOPAY, IDEAL, AND HOLMES. r L- TZ -' - Scott a itto P.E. .. 5 DUKE BLVD. MASON, OHIO 45040 (513) 770 -4800 FLORIDA P.E. No. 63286 8/3/2009 File: DADE CO WORST CASE R00 [Sheetl] MIAMI -DAD • MIANII -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUR DING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (30V 372 - §339 NOTICE OF ACCEPTANCE (NOA) www.m�iamidade- $[�v/buld'uRe - • • • ; • Clopay Building Products Company : •' • ' • • 8585 Duke Boulevard " "" • • • • • • • • Mason, 01145040 8888.. 8888.. SCOPE: This NOA is being issued under the applicable rules and regulations governing the us01XC� pstructid'1� • • •' . •... • materials. The documentation submitted has been reviewed by Miami -Dade County Product Co nhl a44 . 8 4 : 0 0 0 accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other &W where allpVA by the Authority Having Jurisdiction (AHJ). 00060* • • This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Prof ucrCQntrol DiyW%1 (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to,have this pzgdutt or material tested for uali assurance purposes. If this product or material fails to perform in thC q ty P� Pr Pe �geep�ed mapner. the • • manufacturer will incur the expense of such testing and the A14J may immediately revoke, modify, or suspend ftwUv' of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Single -Car Steel Pan Garage Door with Impact Lites APPROVAL DOCUMENT: Drawing No. 103547, titled "Single Car W8 Pan Door with Impact Resistant Lites ", dated 10123 /06, with last revision dated 11/14/07, sheet 1 of 1, prepared by Clopay Building Products Company, signed and sealed by Scott Hamilton, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. LIMITATION: This approval requires the manufacturer to do testing of all coils used to fabricate door panels under this Notice of Acceptance. A minimum of 2 specimens shall be cut from each coil and tensile tested according to ASTM E -8 by a Dade County approved laboratory selected and paid by the manufacturer. Every 3 months, four rimes a year, the manufacturer shall mail to this office: a copy of the test reports with confirmation that the specimen were selected from coils at the manufacturer production facilities. And a notarized statement from the manufacturer that only coils with yield strength of 30,600 psi or more shall be used to make door panels for Dade County under this Notice of Acceptance ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 06- 1107.02 and consists of this page 1, evidence page E -1, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No 07- 1120.06 Expiration Date: February 21.2012 ?� '9 Approval Date: January 3, 2008 Page 1 Clopay Bulldine Products ComAano NOTICE OF ACCEPTANCE: EVIDENCE SUBM=D A. DRAWINGS 1. Drawing No. 103547, titled "Single Car W8 Pan Door with Impact Resistant Lites ", Utpit. 10/23 /06, with last revision dated 11/14/07, sheet 1 of 1, prepared by C1ppay$uildi4 • Products Company, signed and sealed by Scott Hamilton, P.E. ' ° . ` • • • • B. TESTS 1. Test report on Accelerated Weathering Using Xenon Arc Light Apparats% WASTM &.135, • • • • • • Test Report No. BETI- 06 -A002, prepared by Hurricane Engineeri v& AV Testing, • dnc, • • � • • • dated 11/08/06, signed and sealed by Rafael E. Droz -Seda, P.E. • • • • • • • • • 2. Tensile Test on GE Lexan SLX2432T, per ASTM D 638 and ASTM E & *TsM Reports *No. HETI- 06 -T566 and HETI406-T634, prepared by Hurricane Engineering and Testing. * "ffi;., dated 07/14/06 and 11/08/06, signed and sealed by Rafael E. Droz - Seda „P.W. ' "' : • • • • 3. Test report on Self - Ignition Temperature (ASTM D 1929), Rate of Burn°CASTM D %361 end • Smoke Density (ASTM D 2843), Test Report No. ETC -06- 102417496.0, dated 031:1706, signed and sealed by Joseph L. Doldan, P.E. (Evidence Submitted under NOA # 06-1107.02) 4. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 2) Large Missile Impact Test per FBC, TAS 201 3) Cyclic Wind Pressure Loading per FBC, TAS 203 along with marked -up drawings and installation diagram of Clopay 9'x 8' 24 ga. Steel Door, Model 94W8, prepared by American Testing Lab, Inc., Test Report No. ATLNC 1008.01 -07, dated 11/05/07, signed and sealed by David W. Johnson, P.E. C. CALCULATIONS 1. Anchoring calculations prepared by Clopay Building Products Company, dated 10/24/06, signed and sealed by Scott Hamiton, P.E. (Evidence Submitted under NOA # 06- 1107.02) D. MATERIAL CERTIFICATIONS 1. Tensile tests on Painted Embossed Steel, per ASTM E 8, Test Reports No. HETI- 06 -T596, T597 and T598, dated 08/24/06, signed by Rafael E. Droz -Seda, P.E. 2. Salt Spray Exposure Test Report No. 30160-04- 63365, prepared by Stork Twin City Testing Corporation, dated 01/26/05, signed by John D. Lee, P.E. E. STATEMENTS 1. Code Compliance letter issued by Clopay Building Products Company, dated 12113106, signed and sealed by Scott Hamilton, P.E. 2. No interest letter issued by Clopay Building Products Company, dated 10/26106, signed and sealed by Scott Hamilton, P.E. (Evidence Submitted under NOA # 06- 1107.02) Carlos M. Utrera, P.E. F'r oduct Control Examiner NOA No 07- 1120.06 Expiration Date: February 21, 2012 Approval Date: January 3, 2008 E -1 4 3 2 1 CLOPAY MODEL 84A, 94, 98, H94 IDEAL MODELS 4RST, H4ST, 4F END sTw ES ATM^o"E° ro DOOR NOI WITH PATEMIED TOG -L -LOC SYSTEM. END STUB HAVE (2) TOD -L -tAC CLWCH6 AT TOP AND (2) AT 80TIOW ALONG THE FRONT FACE: SECTION B -B of ox T2/oT YW.7WURPOSE HqH BOND' WA VHS; FACADE 1S OPTIONAL HO AA C MODELS S ; 48 21 SECTIONS HAVE ((8) 4) TOB-L -IOC n1NCHES: ® / 02 11 14 7 REJXNED MOM FROM EN S SCRm O STRE. te• SECTIONS HAVE ( TOO -L -IOC CLINCFOS. P.TML D TRACK CONFIGURATION HORIZONTAL TRACK SUPPORT (1) GafFi:1(EOIATE SIRE BEDYEEN EACH 1MS053, DEM D 1tlW1 BD T/R O � a � FOR (S• LHR Tp� BRACKET AnaaED WITH Too- L -LIX.' [( AT TOP & BOTTOM t Hd920NTAi. D URETHANE aoxESlvE W.Om CENTER). OPTIONAL DEODRQK �" DE1COWlAIE A $NP -N P6EWf. FRAYS FACADE ONE RAW (SHOWN) T EITHER GE DSQa00MC SIRUCTUWY, D EP ON! O SECTION (SHOWN) NW-10-THE-TOP sFNAN: waH VER"041. (1) rRAGt ATDIC TO FU BRACKET S PDDNM (NOT 9HIOIWN). L WNH t,) 7/e'.3 /a' ewe ear. L m,m,x Ta�N P AY MAIL WA26VD SIZE 6 18-1 11•. 13 GL WILD. Hi AO TO T. EACH FASTENED 1DW tWADRGDU OIRION CLAIM 6 INJECTION LOBO CF U13AN SUG4327. IABNC /AFPPR CC2 PUYDC 6 ACCORDANCE WITH WOD JWB AM (3) S /1CX1 -1/2 WOOD If4 SCREWS. SR S 1 B-S FOR ASSEMBLY DETAILS. _•� 1 DIPAO' RESISTANT "'� VERT" TRAM AT°CMED ro HORMCA. Hann 1 4 Matto � Lem TRAM WRH (2) 1/4 TRAM BOTS. - - X SOCNINIT FRONT ° SEE INTERNED. HINGE & NAZwo. SS - - ( OETAD. POLYSMWE REAPER - FASENED TO FRAME WrtX 8 Z DALY STEEL TRAM - rt 2 1D g SEE DO fBF2:E DETAL 10 (8 X 1 a PAH HEAD A TRACK THOO435: 0.080 11 34 BZ RS ( 1• =1 Lo� FR MI.M 8. TABLE 1 T(s• r ;L2-,/211 Y -D ..Me ER C I a aaA PxER artl' smEK DOOR HEIGHT secOTONS' 71 PREPARATION OF JAMBS BY OTHERS C 4i - WDmoPAw FWSM GAY. W1HR a '('- XM THE OEM OF THE T PPOR( STTN1CHR7AL ELEMENTS SHALL t s ea s yp• SE tHE PE4W/t�NY O' 1NE P NO OCE WITH T THE S' • r 8{tAOIAi oR S1Itl1CT{INE AND RJ ACCORDANCE CURRENT BUI tWDDr<r oP'ro '�Hf' )NA MA+L DOOR WIDTH = R' - 0 • SECTION A - A 109 O t 0 7 , CODES FOR THE LOAM LISTED ON THIS DRAWING • McA« AAx m.a ,r «xr,Mm1 INSIDE ELEVATION 24 °AEI062W %T WK. T ) ° -( r-2• ""a STEEL ERIOR SKIN JAMB TO SUPPORTING STRUCTURE ATTACHMENT HORIZ cTOP " CALYANIZDY:. GAKEO -ON PRWX AND (NO GOAD FAOY R) A BAKED -oN POLYESTER PAINTED SNAP LATCH ENGAGES TOP COAT APPLIED TO BOTH SOB I. ALL THE LOAD FROM THE DOOR IS TRANSFERRED TO THE TRACK AND THEN FROM THE TRACK TO THE 2x8 kk ONE SNAP LAATTCCIHHOONEA tN�R. S OF STEEL SKIN. (/6TY W. A653). ; HORIZONTAL (TOP) D9 #2 OR BETTER) JAMBS. NO LOAD FROM THE DOOR 6 TRANSFERRED TO THE ma SCE OF 2. ALL JAMB FASTENERS MAY BE (BUT ARE NOT REO TRED TO BE) COUNTERSUNK TO PROVIDE A RUSH INTER. STU SRLE BAIT SUO BOUT LOCH GUIDE EHD ENGA6E4 T I 3. A 1 STRESS P93MASE FOR WIND LOAD WAS SO USED N THE CALCOATON OF ALLOWABLE LOADS FOR 1 OUTSIDE HANDLE g1gE TRACK. f2 GA GALV. STEEL TOP ANCHOAS AND FASTENERS FOR STEEL. CONCRETE AND MASONRY. OUTSIDE END RA DLE S""' LOCK BAR 2,24 L� � / E IE nrr�cHED WOOD FRAME BUILDINGS "am E FIpND ENOWES IN DOOR. STUD WALLS OF DOW OPENING SHALL FRAMED BOLD BY NOT LESS THAN (3) 2X8 PRESSURE ' 0 ' C ' TREATED "am SYP W 4 1{XS e• SHEET xMn °N METAL 5CREM5. (GRADE B2 OR BEffEtt) WONT STIRS OF A STRESS GRACE NOT LESS THAN 1200 PBI NOMINAL EXTREME TIBER Neat OL EACH BIDE IN�('- SLIGE DOLT STRESS IN BENONG STUD TO stb ,ATOM Ltlb[ OPTION LOCK FAR LO]L OPTKN (FJ 1PALt4 10 BE CONTINUOUS FROM FOOTING 7E BFN6. LOCIONO OF COOK. B to c cA. ST EEL JAMB K A L O N R T B 2Xs s» <GPPDE 82 oR BETTER) WOOD B SHALL BE ANCHORED GROUT REINFORCED BLOCK WALL OR END BE . CH CONCRETE COLUMN. BLOCK WALL GELS SXAL BE FILLED WITH CONCRETE AND REINFORCED WITH RENFORONG 2X6 VERTICAL .LOB TA 2 -3/4• 2 -1/4' _ BARS EXTENDING INTO THE FOOTNO AND INTO TIE BEAMS. ALL BARS SMALL BE CONTINUOUS FROM THE TE �� 4) IM/9 SHEE( KM SHOP LAP JOINTS. 1 SHEET W M T � DESIGNED THE BUILDING EN 041 ER OR ARCHI= OF RECORD WALLS AND CONCRETE COL1RdN5 TO BE +. TA" SCREWS. 7 -I /z' 7 -I/2• 3: _.vr. ° aN ::`; : ^:' �d %'NBCit. � U IM M U Sari 2z6 JAMB OT SUPPORTING STRUCTURE IBWK ME AT WAOMUMI O 4 %4•.Xyy//a• SELF J ". r •� PER SECTION. EACH a -BAR TO BE USED FOR aTiMtRENT of TRACK BRAG CENTER TnPPNGS ATTACHED WIN 1/4 • SELF 14 m. FIND IMYMR 1A DI�xiNGe 2 SCREWS AT EACH E� AND °STANCE SIM INTERNED. SIRE LOCATION. BMDHS, TYPE FASTENER TYPE FASTENERS pEDUFAEpp &M (HOLLOW on IAMB CONFIGURATION ?x +'1 :;HIV - ED1 t /a x 3 () -1/4 EYSED) OW TAPCOi CONCRETE ANCHOR (2 -1/2 NOL EDGE DISTANCE) 10-1/2 1 STOP tlOULONC, BY ODOR 17 GA QALY. STEEL BOTTOM OOO MOL a x 4 1 -3 4 -1 4 1 ° T tt T) BRMOhT (3 -1/2' X S -i/2 1 X 4 2 -1 4 FMBEO - -A' MN. 1 -1 MIN 20 GA MN. GALV. STEEL END STA4 2- 5/8 . AnACH WITH ( iaxB a 20 GA MIN. C LV. STEEL INFIRM. STOLE 2S2 FIRST AT NO M t SHEET METAL 1 z , -i x -1 a pR /gCpEp STARTING FROM B�7O1 0€ F MAt�1_T1Y_•}lN tOSTMICE. 12 DA. GA.V. STEEL TRACK ' • NibESI H ANCFIOR /SORE! 68TALLED N LAST AS HCH •I A •• -- BRACKET FASTENED TO VON • IAMB WITH ONE 58 it -t/2 �� S ALUMINUM D(TRUSI N & VINYL WEATHERSTRIP. EXTRUSION .(� • • • • • A WOOD L AG SCREW eRAC¢r. ON ATTACHED WITH SFACCDM [(B) ssmvS ON ov � jr IB •!. • N4. BW288 iDFilGlieIOADS: +48.0 PSF & —54.0 PSF. 18 GA ONLY. STEEL NIEIR HAM FASTENED TO CENTER 2 CALV. STEEL TRACK FASTENED STILE W /(4) EAM 814OX SHEET META. SCREWS. TO TRACK BRACKETS. EACtI T /t8• ROUND 011SIWFT B x6TAltFD ox H:AC11 tiOLER 51AAFI. A T UN O 4B�a C Wb4 .� S.0 SCALED PAGE 5 1 OF t MAX Size BRACKET OL T & K w roE ®�" ®��e : W ED x t2 1/ { BOLT &NUT Q@ iMIO #1 C,. M E T M END HINGE & (4) 1 TO SEW W" W/(a) FAIN tl , >4 y ( .oOOO n ±.DOT DATE, /4• RIVETS. stms/e• &ELT METAL SCR & (4) 1 /a• SEIP TAPPING SCREiFS. Oe9TN4P m tt/2' fD /23 /tJ6 DE IP SINGLE CAR W8 PAN DOOR LOPAY BUILDING : : s� s / 18;; Building Products MASON. owo� o f i D WITH •m`"", RESISTANT L s vM Com an 513 no • • • • sr! • • B 103547 MD 4 3 2 '•• •• • • • 1