Loading...
138 NE 92 St (2)STATE OF FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS EMERGENCY MANAGEMENT • HOUSING AND COMMUNITY DEVELOPMENT • RESOURCE PLANNING AND MANAGEMENT LAWTON CHILES Governor Lewis Hartley Robin Builders P 0 Box 1067 Lake Wales, Florida 33859 RE: 1995 -96 Annual Renewal Based on the 1991 -SBC's Manufacturer's I.D. Number: RBI -18 This Approval Expires June 30, 1996 Dear Mr. Hartley: It is my pleasure to inform you that the Community Affairs has renewed Robin Builders approval to manufacture residential utility lawn buildings for installation throughout the State of Florida except Monroe County. This renewal is granted pursuant to inspection of your submitted plans which were found by this department and your inspection /plans review agency to be in compliance with the applicable codes. On site installation requirements are specifically and entirely reserved to local authorities. These requirements must be reasonable and uniformly applied the same as for conventional construction. A copy of this letter must be attached to the approved plans when making application for local building permits. LHJ cr cc: FSC April 28, 1995 Sincerely, Lawrenc : Jordan Planning Manager Manufactured Buildings LINDA LOOMIS SHELLEY Secretary 2 7 4 0 C E N T E R V I E W D R I V E .• TALLAHASSEE, F L O R I D A 3 2 3 9 9 - 2 1 0 0 f IORIDA KEYS AREA OF CRITICAL STATE CONCERN SOUTH FLORIDA RECOVERY OFFICE GREEN SWAMP AREA OF CRITICAL STATE CONCERN FIELD OFFICE P.O. Box 4022 FIELD OFFICE 2796 Overseas Highway, Suite 212 8600 N.W. 36th Street 155 East Summerlin Maratlnn,Florida 33050.2227 Miami, Florida 33159 -1011 Banow, Florida 3383046:1 V. JOHN KNEZEVICH, P.E. JOHN W. KNEZEVICH, P.E. November 8, 1995 Mr. Harry Jordan Sheds America 9660 NW 77th Avenue Hialeah Gardens, FL 33016 RE: Shed Soil Anchors Dear Mr. Jordan: Knezevich & Associates, Inc. has reviewed the 1994 South Florida Building Code, including its ASCE 7 -88 provisions and determined that the enclosed table may be used for soil anchors manufactured by Tie Down Engineering. These tables were prepared for sheds shown on State of Florida approved drawings, Nos. RCA -93 and 149 -004, with maximum wall height of 7' -8" and for helical, drive and slab, type anchors only. We have enclosed the Tie Down Engineering Dr. No. MHP -101, Helix anchor, Dr. No. MHP -110, Cross Drive rock anchor, and MHP -120 Patio Slab anchor as acceptable reference drawings. One strap, 1 1/4" wide x 0.035 thick, connecting two anchors on opposite sides shall be used. Strap models and material properties are shown on Tie Down Engineering's Dr. No. MHP -305. Ver j rttly, cc: file Pres'•ent KNEZEVICH & ASSOCIATES, INC. V. J. nezevich, P.E. 641 MOKENA DRIVE MIAMI SPRINGS, FLORIDA 33166 PHONE: (305) 883.9571 FAX: (305) 883-9572 CONSULTING ENGINEERS • PRODUCT TESTING 2701 WEST OAKLAND PARK BLVD SUITE 240 FT LAUDERDALE. FLORIDA 33309 PHONE: (305) 677 -9500 FAX: (305) 677 -2997 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 38 37 38 39 40 41 42 43 44 45 46 47 48 ': TO 9E UOE) WITH DRAWING RCA - & ROBIN BUILDERS N0.149 -004 SOIL ANCHORS SCHEDULE' mE -OOWN ENGINEERING. INC.) SIZE W x L (F71 TOTAL NUMBER OF ANCHORS 3 x 5 4 3 x 6 4 3 x 8 4 3 x 10 4 4 x 6 I 4 4 x 8 1 4 4 x 10 1 4 4 x 12 I 4 5 x 7 4 6 x 6 4 6 x 8 4 6 x 10 4 6 x 12 4 6 x 14 6 6 x 16 6 7 x 9 4 8 x 3 4 8 x 10 4 8 x 12 4 8 x 14 4 8 x 16 4 8 x 18 6 8 x 20 6 8 x 22 6 8 x 24 6 10 x 10 4 10 x 12 4 10 x 14 4 10 x 16 4 10 x 18 6 10 x20 6 10 x22 6 10 x 24 6 12 x 12 4 12 x 14 4 12 x 16 8 12 x 18 6 12 x20 6 12 x22 6 12 x 24 8 12 x30 8 14 x 14 4 14 x 16 6 •• .14 x 18 8 14 x 20 8 14 x22 8 14 x 24 8 ' 14 x 30 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 38 37 38 39 40 41 42 43 44 45 46 47 48 ': TO 9E UOE) WITH DRAWING RCA - & ROBIN BUILDERS N0.149 -004 LTR. DATE DESCRIPTION I o -t -b . REVISIONS tie down engineering, inc. 500I wnraron O . Aroma Otago 30 »:: T I TL e • OCeL MI221�g), .�I2Z (b /4I LnubLC -NeU ANTI-1 ANC4 N DR. IT Y,.tiOAC < 1 CX. IT. C. M3CI'`}APiVI01 SCALE NONE DR. NO �+ r / f 1. ` F. `J PtRAH 1.4 e- ►.! T 71'1 To G ICA 3 1le0" F;tt LJe.td 1 LLD p A ��Shcrpa �� ., Edets �L 30 4" - T� NOTE MATERIAL SPECIFICATIONS HEAD •AIS!•C10085go. ROO • ASTM A - 36 MOD WELDING ELECTRODES - UNCOLN INNERSHIELD NR •311. or EOUN. BOLTS • ASTM A- 307 ALTERNATE ANCHOR ROD- >V.• DIAMETER (IF REOUIRED) ANCHOR FINISH - ENAMEL OIP or GALVANIZED (IF REOUIRED) BOLT FINISH • ZINC PLATED - Tr=NSlon Eocrs (MoDeL bI56) AP,E -11 x 2 A4" uE'X t-lEAD 'i /SQUAN NECY- (ZINCPLATED)WNQ T5. - TC451011 EOLT LABELED `' FON FRAMI` ATTACI4MeNT ONLY. - TENSION BOLT LAEELEO * FOP- VEPTICALMN31014. LT1. ( DATA [ 0 ISCIIPTION 1 7 -22-571 [[VISIONS tie down engineering, inc. MI wPwi0.. 0"... .w..Q .'.00 7Csa TITLI MOCEL ANPA 4.m.pday. 48 CROSS ORs"E RcC)S P8Oa 01. 1Y K.NOAC1C cx. 11 C. Mx KARVIC H SCALI NONE 01. NO Mup 110 4 hEX NO. rA 8 J I pStO (1 i 3'.30 'id" o /dH'4a Roc Pk A 44 me: S ua% "achPi 4 th s X6., ._� a: . -. . -off 3p INSTALLATION INSTRUCTIONS DRILL 3" DIA. HOLE 51/2" DEEP FOR PILOT STUD. INSERT PILOT STUD INTO HOLE. DRILL 2 - DIA. HOLES IN ROCK AT 45 DEGREES ANGLES. USING ANCHOR HEAD AS A LOCATING GUIDE. PLACE ROD THROUGH TOP & CORRESPONDING BOTTOM WEB FLANGE & INTO HOLE. DRIVE ROD TO DESIRED DEPTH. (ROD MUST BE DRIVEN INTO ROCK AT LEAST 80% OF ITS LENGTH IN ORDER TO ACHIEVE MINIMUM ALLOWABLE PULLOUT RESIS- TANCE.) PLACE SECOND ROD THROUGH REMAINING TOP & CORRESPONDING BOTTOM WEB FLANGE & INTO HOLE. DRIVE ROD TO DESIRED DEPTH TO LOCK. MAXIMUM PULLOUT RESISTANCE IS DEVELOPED WHEN ANCHOR HEAD IS AS LOW AS POSSIBLE AND GROUND SURFACE IS SOLID ROCK. DISTANCE FROM LOWEST EDGE OF BOTTOM FLANGE TO ROCK SURFACE SHOULD NOT EXCEED r (INCH). NOT[ 05 Mi , 1 �. brz *4 Ave � • ��'" NsevE 8Q �� • F ►t 4 MATERIAL SPECIFICATIONS HEAD • AISI • C 10385 g al ROD •ASTMA -38MOO WELDING ELVES • LINCOLN INNERSF00.D NR - 311. of ECUN. BOLTS • ASTM A. ALTERNATE ANCHOR ROO . Ai DIAMETER IIF REOUREO, ANCHOR FINISH - ENAMEL 01P of GALWNIZED IIF REQUIRE BOLT FINISH . aNC PLATED — TENSION SCLTS (MODEL [3XSB) ARE 3 /6= x 2 2 4"L. NEX NEAR /SOuARE NECK CZ) NC PLATED) u )/N L7TS . — TENSION BOLT LABELED ® FoR FRAME ME ATTACI . MENT ON 6y. - TENSION CioLT LABELED FOR VERTtcAL TEN S tCN. I, T1. I DATI I DtSCZIPTION 1 8-1-821 RtVIIIONS tie down engineering, inc .01.... •••• Amnia G.a .o r43° TITLt MIODe".... MIC52- PATIO SLAE 4N0-4OR YEXPANSsCNf'CLT 0 R. IY 1 CX. IT. C. MDcn NVICI -1 ICALI NONE 0Z. NO MNP -120 PtRMAASEwt T 11 l1s . juke- pais t (/ P� Slo S d$sc;o - %''ct) x j' DEEP uOLE FS QUIPPED IN SLAb MATERIAL SPECIFICATIONS HEAD • AISI • C 1008 5 qa. ROD • ASTM A • 38 MCO WELDING ELECTRODES • LINCOLN INNERSHIELD NR • 311. or EOUIV BOLTS •ASTMA•307 ALTERNATE ANCHOR ROD • as' DIAMETER I1F REOUIRED) ANCHOR FINISH • ENAMEL DIP Of GALVANIZED OF REQUIRED) BOLT FINISH • ZINC PLATED NOTE --- z inc PLATED INSTALLATION INSTRUCTIONS DRILL W x 3" HOLE. PLACE STEEEL EXPANSION SLEEVE OVER BOLT & PLACE INTO HOLE. PLACE WASHER OVER TIP OF EXPANSION BOLT. THREAD NUT ONTO EXPANSION BOLT & TIGHTEN NUT UNTIL MAXIMUM EXPANSION OF STEEL EXPANSION SLEEVE HAS BEEN ACHIEVED. REMOVE NUT & WASHER. PLACE WASHER OVER EXTRUDING TIP OF EXPANSION BOLT & TIGHTEN NUT. NOTE: CONCRETE 1D BE 2500 PSI MIN. SLAB TO BE 4 "• MIN. THICKNESS WITH 6/6 x 10-10 WIRE MESH. CONCRETE SLAB SIZE TO ALLOW 4750 LIIS. VERTICAL TENSION ON ANCHOR W THOI'T LIFTING SLAB. ASSUME CON- CRETE WT. OF 150 LBS. /CU FT. - TEN-51011 EOL75 NODCL bI5b)APIE - 11 x 234' I-I Y I-IEAD u /SQUANE Nt=CY- (ZINC KATCD) 0 / N TS. TCH510t'1 BOLT LAbCLED <> FON FP,AMt ATTACHMENT ONLY. T&S10N BOLT LAbcLED ® FOP V1=fiTICAL TENSION. 9 ITR. DATE DISCRIPTION 8-182 RRVISIONI Z tie down engineering, inc. S901 Wm Atcrea Gaga 701]0 1 TITLE MODELAIU.1T6 MEU7 Ff�AM TE5 OR. SY 1`'1.NOAC',16, Cx. Rr. C. Aacl5AN\I1Q4 SCAT/ rbNE DR. NO�UP - 305 r NOTE- � - eA LVANImp SmAPPIh1G : C>:hTIRED TO tIkt151 A119.1 .035' MIN.x14dx Fr. , - stiNze NWRY %WD tVEP. f 12' AS PPPti FOLI..OU IN - ne POIJN EN6IneEP IHS CFiDD TO Ate, 1 19.1 FED,_ SPEC. - 5781 -8 - MOOCL 1-1T6 4- 1001 AMD MODEL - e,u7 bL C1'il.e- Ate. ZINC CAA1'ED fcQ1 COP,PvootON PE515tANCM.. ■1 Model No. MI2H 5/8 Vertical pull -out in dense sandy limerock 7697# fill. ASTM D1586 Blow Count 19 -36 (avg.) 11 -29 -79 6 Vertical pull -out in dense sandy limerock 7590# fill. ASTM D1586 Blow Count 19 -36 (eug,) 11 - - 6 Vertical pull -out in dense sandy limerock 7566# fill. ASTM D1586 'ate.) 11 -29 -79 7 Vertical pull -out in dense sandy limerock 7816# fill. ASTM D1586 Blow Count 19 -36 (avg.) • 11 -29 -79 7 Vertical pull -out in laboratory fixtures for 13,150# simulation. Unconfined rock was not available Vertical pull -out in dolomite rock formation 7249# with unconfined compressive strength of (avg.)- 3800 psi 3-6-80 Vertical pull -out in 3000 psi cured 6925# concrete MIJ2 Anchor model was installed in 2500 psi 9740# nominal compressive strength concrete. Cure time 48 hrs. MIT2 Anchor model was installed in 2500 psi 10,980# cured slab and vertically pulled to destruction. Vertical pull -out in dense limerock fill. 12,100# ASTM D1586 Blow Count 30-42 5 -16-82 13 Formal Testing not available 2500#4 (est.) 13 Formai Testing not available 500# (est.) 13 NOTE: All above tests were conducted by Pittsburgh Testing Laboratories. The individual results of these tests will be made available on request. Please forward your request for this information to: MI2H 11/16 M I22 5/8 MI22 11/16 MRA M I R2M MCS2 ME48 M E30 ME 15 IRON ROOT INDEPENDENT TESTING RESULTS Ultimate Description of test strength Test Date Ref. Page TIE DOWN ENGINEERING, INC. 5901 Wheaton Drive Atlanta, Georgia 30336 11 -29 -79 8 9 3-6-80 10 5 -16 -75 11 5 -16 -75 12