1250 NE 93 St (7)PHONE 78 -3678
A. w. 1=1 1 LIDETT
Village of Miami Shores
Dear Sir:
GENERAL CONTRACTOR
144 Northeast 88th Street
Miami, Florida
December 19, 1955
1250 N.E. 93rd. Et.
This is to inform you that as onmer of 1250 N.S.
93rd. Street, I will assure all responsibility for
the air conditioning unit which is set on the West
side of my house.
To completely hide it from view,, I am surrounding
the unit with shrubbry which will also cloak any
noise.
If at any time in the future, there are any complaints,
I will move this unit to some o':;her location.
MIAMI SHORES VILLAGE
BUILDING INSPECTION DEPARTMENT
APPLICATION FOR BUILDING PERMIT
Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build-
ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the Building Division of Miami Shores Village shall be complied will, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
Owner's Name and Address ('Al•
/ / - d
Street and Number where work is to be done / <
State work to be done and purpose of building (by floors) .o.(4-
D.ite
Street A
Registered Architect and /or Engineer
Name and address of licensed contractor // =_1�ra.���?Q.��� =
Location and legal description of lot to be built on:
Lot Block Subdivision
and for no other purpose.
New Building Remodeling Addition Repairs No. of Stories
To be constructed of Kind of foundation Roof Covering
Estimated Total cost of improvements $ /1 Amount of Permit $ ti ?�
Zone cubage required .Plan Cubage
Distance to next nearest building Size of Building Lot
Maximum live load to be borne by each floor
I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may
be sent to
The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer
of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement,
and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him
in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice
or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this
permit, as are licensed by Miami Shores Village.
Remarks (Signed)
STATE OF FLORIDA,
COUNTY OF DADE. ss.
Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap-
peared
to me well known,
and who, being by me first duly sworn, upon oath deposes and says that he is the.
of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts
therein by him stated are true.
Permit No. Date Read, Swcrn to and Subscribed before me.
Disapproved Date
Notary Public, State of Florida
(Signed)
Building Inspector My Commission Expires
PLANNING BOARD DATE
Chairman Member
Member Member
Member ...__ .. Member
Council Approved Date Disapproved Date
NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from
the Planning Board.
A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty
materials and /or workmanship.
APPLICATION FOR BUILDING PERMIT
Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build-
ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
MIAMI SHORES VILLAGE
BUILDING INSPECTION DEPARTMENT
Owner's Name and Address -- -
Registered Architect and /or Engineer
9
Name and address of licensed contractor
:)ate q / 67 �
No Street
Location and legal description of lot to be built on:
Lot Block Subdivision
Street and Number where work is to be done / 5 :__- _____ 9..2
State work to be done and purpose of building (by floors)
and for no other purpose.
New Building Remodeling Ad • tion Repairs No. of Stories
To be constructed of Kind of foundation R of Covering
Estimated Total cost of improvements $ - Amount of Permit $ ,�
Zone cubage required plan Cubage
Distance to next nearest building Size of Buik ing Lot
Maximum live load to be borne by each floor
I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may
be sent to
The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer
of labor under the Florida Workmen's Compensation Act, being Section 5966, Co npiled General Laws of Florida, Permanent Supplement,
and has complied with the provisions thereof, and will require similar compliance from all contractors or sub- contractors employed by him
in the work to be performed under this permit; and will post or cause to be poste. for inspection on the site of the work such public notice
or notices as are required by the Act. The undersigned agrees to employ only such subcontracjrs, on work to be gerfo, ed under t is
permit, as are licensed by Miami Shores Village.
I emarks (Signed)
,19
STATE OF FLORIDA,
COUNTY OF DADE. j ss
Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap-
peared
to me well known,
and who, being by me first duly sworn, upon oath deposes and says that he is the
of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts
therein by him stated are true.
Permit No Date Read, Sworn to and Subscribed before me.
Disapproved Date
Votary Public, State of Florida
( Signed)
Building Inspector My Commission Expires
PLANNING BOARD DATE
Chairman Member
Member Member
Member .. Member
Council Approved Date Disapproved Date
NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from
the Planning Board.
A re- inspection fee of 51.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty
materials and /or workmanship.
electric Heat Pump.
1 /
nnounclnpJ.
The new COOLER- HEATER Central Air CondlEMEMMIEMMEEMEhr
UItimate in Florida Living. Cools, Heats, Deh 1 ,
maximum all -year, all- weather comfort under all con( itions wit) 1 )e ami►zin(c 1-
• Cool in Summer.
Enjoy vacation weather all summer long. Sleep restfully every
night. Have ideal climate all day long in every room of your
house. Controls temperature and humidity automatically.
• Heats in Winter.
When temperature drops, flip the reverse cycle switch and
COOLER - HEATER goes to work heating your whole house
with clean, filtered, healthful air.
• Designed for Florida.
Designed specifically for the Florida climate to assure maxi-
mum performance. Manufactured locally, using copper and
aluminum condensers and evaporators to last indefinitely.
Undercoating is used to protect other parts from rust and
corrosion.
• Low in Cost.
Low Initial Cost and easy installation plus low operating cost
make the COOLER - HEATER system within reach of every
home owner.
• Quiet in Operation.
Keeps compressor noise and vibration out of house. Circu-
lates air at low velocity. Street noise and dirt are kept out
when windows and doors are kept closed.
• Easy Installation.
With Heat Pump outside and Air Handling Unit in the top
of a closet, no space is lost in the house. Using a plenum
chamber eliminates costly duct work in most installations and
simplifies system.
• Completely Air Cooled.
Needs no water pumps, wells, towers, etc., for efficient
economical operation.
Al HANDLIN
MODEL
255 CH
355 CH
555 CH
Nominal Rating
1 -2 Ton
3 Ton
5 Ton
Compressor Motor —HP
1.75
3
5
Condenser Fan Motor —HP
1/3
1/3
1/2
Evaporator Fan Motor —HP
1/4
1/4
1/3
Condenser Face Area —SF
5
5
7.5
Condenser Coil —Rows
3
4
4
Blower CFM
2,200
3,500
5,500
Evaporator Face Area —SF
2.25
2.25
4
Evaporator Coil —Rows
3
4
4
Blower CFM
800
1,200'
2.000
Refrigerant
F -22
F -22
F -22
Booster —KW
1.5
2
3
Weight —Net. Approx.
720
780
1,060
Weight —Gross Approx.
770
840
1,140
Dimensions —Heat Pump — Length
35"
35"
41"
1 Width
31"
31"
36"
Height
26"
26''
32"
Dimensions —Air Handling Unit —
Length
36"
36"
42"
Width
23"
23"
29"
Height
20"
20 ".,
26"
PERFORMANCE - COOLING
Based on 90 Ambient Outside Temperature with 80 DB and 67 W8 Inside Temperature.
Total BTU
28,000
39,000
66,000
Sensible BTU
19,000
29,000
49,200
Latent BTU
9,000
10,000
16,800
Leaving Air —DB
55
54
55
Leaving Air —WB
53
52
53
PERFORMANCE- HEATING
\ Based on 40 Outside Temperature and 70 Inside Temperature.
Total BTU '
32,000
48,000
80 000
Leaving Air =DB
110
114
114
BEDROOM
PLENUM CHAMBER J
BATH
BEDROOM
Typical Installation of COOLER- HEATER Air Conditioning System
CONDENSATE DRAIN LINES
COOLER HEATER
AIR HANDLING UNIT
• BEDROOM
1TCHEN
PLENUM CHAMBER
J
' CO NDENSATE DRAIN LINES
I
REFRIGERANT LINES
LIVING ROOM
DINING AREA
pOOLER- HEATER AIR HANDLING UNIT
EFRIGERANT LINES
COOLER - HEATER HEAT PUMP
SPECIFICATIONS AND RATINGS
COOLER.HEATER
HEAT PUMP
ON CONCRETE SLAB
TER
C0 OLER•HE1
HEAT PUMP
ON CONCREI
BEDROOM
PLENUM CHAMBER J
BATH
BEDROOM
Typical Installation of COOLER- HEATER Air Conditioning System
CONDENSATE DRAIN LINES
COOLER HEATER
AIR HANDLING UNIT
• BEDROOM
1TCHEN
PLENUM CHAMBER
J
' CO NDENSATE DRAIN LINES
I
REFRIGERANT LINES
LIVING ROOM
DINING AREA
pOOLER- HEATER AIR HANDLING UNIT
EFRIGERANT LINES
COOLER - HEATER HEAT PUMP
SPECIFICATIONS AND RATINGS
COOLER.HEATER
HEAT PUMP
ON CONCRETE SLAB
TER