Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ROOFING
Stre ancf NumIl w State work to be done and purpose of building (by floors)_ Roofing on nevTres1dence Council Approved MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Snores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Date "'e)Jr•Lbn Ty 13 Owner's Name and Address Z I r • & Mrs • Louis Rice No Street_ Registered Architect and /or Engineer Name and address of licensed contractor Sheet i e e t eI p ec . Co. f 573 A . II. 71s t St., : i . Location and legal description of lot to be built on: Lot E. 50t Of 5 Block 1 Subdivision Bey Lure ere work is to be done 1235 Y. E. 93rd Street_ I9 be and for no other purpose. New Building X Remodeling Addition Repairs No. of Stories on To be constructed of C • E • $ • Kind of foundation Roof Covering t _ le enc bu 1.7 ;: up Estimated Total cost of improvements $ 985.00 Amount of Permit $ 5 Zone cubage required _Plan Cubage Distance to next nearest building ________Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Remarks (Signed) SHEET :1EJ'AL SEE CIAL`_T CC7 STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared __ to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No. Date Read, Sworn to and Subscribed before me. Disapproved ___ Date Notary Public, State of Florida (Signed) Building Inspector My Commission Expires PLANNING BOARD DATE Chairman Member Member Member Member Member Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. UILDING :LECTRICAL LUMBING OOFING )weer of uilding MIAMI SHORES VILLAGE. FLORIDA ❑ DATF 195 ❑ PERMIT N° 3 210 Contractor's License No. O Work to be performed under this Permit rchitect ontractor = Builder ;gal Lot escription ddress of iilding CONTRACTOR OR BUILDER Bl. Subdi- vision Value of Project $ Amount of Permit $ This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application -refer in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, Swings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any ae if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is anted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations rtaining to the work covered hereby whether shown on the plans or drawings cr in the statements or specifications and that he assumes responsibility for work ne by his agents, servants or employees. Signed. BY INSPECTOR In consideration cf the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations rtaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In ac- , ting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. BY AUTHORITY e As • Village of Miami Shores N 3739 JOB / / ADDRESS 21r) INSPECTION TIME READY 9 REMARKS INSPECTOR DATE APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Address Mrs. Paul Dunn Registered Architect and /or Engineer Name and address of licensed contractor Lang. R ofij g & Tie Inc_._.371 1._- W.m...71st_ .St.., MiaTni 3315Q Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done 1237 N. E. 93rd Street State work to be done and purpose of building (by floors) Partial re -roof: Tear off gravel roof on flat deck and replace with a new 4-ply asphalt___LanCi__grave.l roof. and for no other purpose. New Building Remodeling Addition Repair a rOOf No. of Stories To be constructed of Kind of foundation Roof Covering__ Estimated Total cost of improvements $ 275.00 Amount of Permit $ 5.5 Zone cubage required plan Cubage __ Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor___ _. I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to - -- - -- --- - -- The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Pennanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such bcontractors % work to be perfo ; ed under this permit, as are licensed by Miami Shores Village. Remarks._-_ 4 s:0! (Signed) v� J � ` -,074 STATE OF FLORIDA, COUNTY OF DADE. ss Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared Permit No._ Y Disapprove _ (Signed) Building Ins MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT at tor Date January 20th - - - -- ,19 No 1237 Street N . E. 93rd Read, Sworn to and Subscribed before me. to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated am t Datef Notary Public, State of Florida My Commission Expires LANNING BOARD__ -. DATE Chairman Member Member ____ Member Member ._ __ Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. Date Mortgagor APPROVED: PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Job Address /Qan /0 • E . Q/3.s.i Tax Folio A/ „9:&-4 7 4% ' , Legal Description �®r� wLyo '& #61 jell Q / Lessee / Tenant kJ); e )a,) P e- Master Permit # 3 Owner's Address J .3.0 At E. 9 Phone 95 f )4 ) Contracting Co. ,d ! _T (iK 1C- ©or- N/ti Address /r16 ,.0 L). & ;& Qualifier I'Lrrti ( J' ,,s7 u , ih SS # `/ Phone , Y,% Y 2 ? 95 State # e &., (WW)Municipal # Competency # Ins .Co. Architect /Engineer qii Address Bonding Company I P Address 01 p Signature of owner and /or Condo President Date: Notary as to Owner and /or •:,.• �EfttCorujO My Commission Expires: fi r. `• TATE OF FLORIDA My Cornm Exp4/4/94 BONDED ** * * * * * * * * * Zoning Building Mechanical Plumbing_ Permit Type(circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL 'OOFING,'PAVING FENCE SIGN WORK DESCRIPTION 2ernou? ,1 U 1E4 l --�A a . rr� 2 � , Square Ft. z CO Estimated Cost(value) 1) '4 ()c- t WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. Signature o Contractor Owner- Builder Date: Notary as to My Commissio Contractor or Own Builder STATE FVLO My Comm ExP4/4/9 pONDE Y * ** FEES: PERMIT .'D RADON C.C.F. 9 NOTARY TOTAL DUE 1 )` d ` C. Fire Other Electrical Engineering MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed state ,,u nt or tree plans and specifications herewith submitted for the build inc or other structure herein described. This application Is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the. Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the iuilding Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Date. Date..._ JIdZ� 14 ta 1, •. 2 � .. » ». ,19z ? 93 .—..—... a o...._.........._.._... Street_ _ 1237 N. Owner's Name and A Address ....: ...... Registered YittbUtit and /or fanincer. • i r C€. �tDO'~g'Z .a I%lC Name and address of licensed 2i W Pierce ROOfjrtr tnc ? i ilft - - - Roo - � • • ? 7. � �,..:..cL.. �t>Sikt sass.. »... a �. ... . 53.� »..���....... i.i.»%;I..3.$. Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done 1237 _ '! 2 93 Stj ti$...._.d:.z.. .._ .rear„ .1.0.r. . — State work to be done and purpose of building (by floors) Ile na � 'LO )Z i -- • — �? �.4s --a te• ••• y x CI _?'"^ it ti1.. ^. �.°.':.� Uulit u. ? i��(' ';b:�S� 112 i-1 ...._ _. _........_ _ - y $ sass_...» »........... for no other purpose. New Building Remodeling Addition e¢alir XXX No. of Stories To be constructed of Kind of foundation Estimated Total cost of improvements Building Inspector se 330Q00 Amount of Permit $. Zone cubage required Plan Cubage Distance .to next nearest building. Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to .. 0.,.C:E.ca...e.' nrl'^i"b (, ILIC. 2.72.1 ..5.. "•T .6.9.. Co•ur•t _' a7 . 7 r :s. a.) ...... The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of l.thur under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Sup lenient, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors emplo him in the work to be performed under this permit; and will post or cause to be posted for ' spection on the site of a work su public otice or notices as arc required by the Act. The undersigned agrees to employ only such '),tractors, on •rk be per . ed er this permit, as are licensed by Miami Shores Village. Chairman sfcrr,ber Member .. .. — Council Approved Date NOTE: A charge of $1.00 will be made for the Planning hoard. A rc•inapec•tiun fce of $1.00 will be charged materials anti /or workmanship. ...•••,u•..t to K,.,Yf•tt! ^.., Roof Covering .lI .f• t t t 12,) t o , ; Remarks (Signed).. _........_. CCs 1022C STATE OF FLORIDA, COUNTY OF DADE. } se. o 261 °65°2143 Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared -- — --- to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the stone, and that all facts therein by him stated are true.. Permit No.._ > .L •-3 Dat / / � /a Disapproved Date (Signed) (Signed ) Read, Sworn to and Subscribed before ste. Notary Public, State of Florida My Commission Expires ,„...• »,. _.., ._......_...r...._ PLANNING BOARD DATE Member . .... ... ... . . ....... _ Member .. — Member sass_ __.._sass._ — Disapproved Date making corrections or changes to this application after approval has been obtained frmn when such re- inspection is made necessary by Improper notice for inspection or faulty 1 c 7 h 6 Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Ow:nei s Name and Address ... ./. Registered Architect and /or Engineer Name and address of licensed contractor...L.6 ..... 7b> 8.I.!Q.._d. .E .._.I .....0..t r1r'� Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done State work to be done and purpose of building (by floors).. _ r <e-7 o. � .2, - P and for no other purpose. New Building Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Coverin O� V0% Estimated Total cost of improvements $ `Yj � Amount of Permit $. Zone cubage required plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer of labor under the 'Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employe by him in the work to be performed under this pennit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work . o be performed under this pennit, as are licensed by Miami Shores Village. Remarks (Signed) . STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stat?de tnie. Permit ermit o. ._ Disapproved (Signed) MIAMI SHORES VILLAGE APPLICATION FOR BUILDING PERMIT Date.. Date.. Building nspector i — Aay Commission Expires PLAN C BOARD DATE Chairman Member Member Member Member ..... ___..._.___. ......_ Member Council Approved Date Disapproved .................. ..Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re inspection fce of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. BUILDING INSPECTION DEPARTMENT Date... .._.... 19. d U .O f S. d. _ No / . Street. L. �$ -• . It ead, Sworn to and Subscribed before me. Notary Public, State of Florida to me well known, 4 PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 7 b by Job Address 1217 0.a ca v IGtKI( F3 i3 Legal Descriptionlok'S Tess wt.y ascvcc lot 6 61,14. ! $4.3 (spire. Pe, 44 -63 Owner's Address Contracting Co. Qualifier My 1 �b Signature • f o r r ondo President 1 ate 1 ' Notary as to Owner and/or Condo President Dat APPROVED: Zoning Mechanical GILDA PEREDA Buil ; rte , ' , MYCOMM'SSION .1 CCSIM.,5 ��i FF.�'� FIRES: Oct 25, 2003 1.-;1 3s "3 AnY F,.s. C,ctay Sm:v) G fJart .rg Co. :ar1 FEES: PERMIT RADON Plumbing • C.C.F. Historically Designated: Yes Owner/Lessee / Tenant triq R.K. 4i4 { }� �S Master Permit # 9 7/32 Gam, •331 Fl , 3 0 j . IoA s •� / / L Phone &5 T 5c) 1 .5/ A 7'1 s 1 CK Ci A, Address (50/ I NW 3 /j/' .unit (iC a State # (rcrs-79a t'. Municipal # Competency # Ins. Co. Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN 71/ O (k. c v c )1 WORK DESCRIPTION f _,i a � It✓ c i /90/hheafl 4. &41 .8C s& i AA cegi /Mato Mod e (y . Square Ft. .2 ! Estimated Cost (value) of C ./ 7 S . WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. a ontractor ox er- Builder t Notary as to Contractor or My GILDA PEREDA � Y COMMISSION 0 CC Fes$ 3 � ,h• 174 '07 70' EXPIRES: Oct 25, 21,'03 Y 1.CDO.3- OTANY Fla. Notary Soroica $ Eos ;.r.3 Co. 1 NOTARY BOND Structural Engineer s4 '�6c< o f Phone 9 � ... - Builder .iii TOTAL DUE :5 No Date tofr NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: 8Lk gA4 wvtle PS 41.4 — 63. 1`or ,E ' I a3`7 cf3sr NI sAMf S'51 2. Description of improvement: e ^12 3. Owner(s) name and address: MA/C.11 P UMO WIT . /037 /VE q 357 I MAM Interest in property: Name and address of fee simple titleholder: 4. Contractor's name and address: 5. Surety:(Payment bond required by owner from contractor, if any) Name and address: ti i Amount of bond $ 6. Lender's name and address: / A 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: • •//N-- 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: rr' /A 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) Signature of t Owneer Print Owners Name Sworn to and sub Notary Public Print Notary's Name My Commission Expires: MACH tJM6( ed before me this 1 day of 51.) L1 , STA E OP FLORIDA, COURIT ® 041C I HEREBY CE'RPIP sngina• Pile6� b rnartn/ssa buoc.,, PPAe � office on S nir Nw Ave . osva v�� D. J. COPELIN 1 cS COMMISSION # CC 693346 ten_ cal EXPIRES NOV 2 2001 Of l ATLANTIC ONDING CO INC. 00R334803 2000 JUL 12 11:57 Prepared by: 1 C41414. Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. Contractor's Name: Al c\S \?JA Job Address: /d%37 Ai Er 9 3 S r ► 4 YA-1 1 �/ L7 ROOF CATEGORY � LSD (Low Slope Application) ❑ (Nail -On Tile) (� Adh Mortar- ere Set Tile) ❑ (Asphalt/Fiberglass Shingles) ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other) � ROOF TYPE ❑ New Roof E� Re- roofing ❑ Recovering ❑ Repair ❑ Maintenance Flat Roof Area (ft WI 0 . Sloped Roof Area (f 2 ) ?i$OO Total (ft 38D 0 . Master Permit No. Exposure category (per ASCE 7 -88): C. Building Classification category (per ASCE 7 -88 table 1): L Ft. A Ft. A V sracc pp Prae Fastener Type: 6'Govge -oiue r Deck type: s p /iwoc J ATTACHMENT SPACING j( Field: (9 Perimeter: Corner: t DETAIL 1 & 2 ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed 0 123.01 -78 4/99 Page -1 Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. Rid nti t n MEAN HEIGHT Deck type: i wc-O z Underlayment: Insulation: 30Ib < 12" ROOF SLOPE D E T A I L 3 SLOPED SYSTEM DESCRIPTION N/ A Fastener type & spacing: Cap Sheet: Roof Covering: Drip edge: toc 6" � --o I ©L(. (i' ,4M An go . ATTACHMENTS REQUIRED I) Fire Directory Listing Page 2) Miami -Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals TILE CALCULATIONS (Pmaxl: X ? (Aerodynamic Multiplier): ' 21 ) - M { Mr1: S7 7 PCA: ad_ (Pmax2: gib • S x X. (Aerodynamic Multiplier): '21 ') - mg:(? t4 = M 2(.3f PCA: I ' q (Pmax3: ( X X (Aerodynamic Multiplier): J2 ) - M = M r3 : a�' PCA: 21 As it pertains to this Appendix "F', it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, to provide the owner with this appendix and to explain to the owner the content of this form. The provisions of Chapter 34 of the South Florida Building Code (SFBC) govern all the minimum requirements and standards of the indus- try for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained. fi 1. Aesthetics - Workmanship: The workmanship provisions of Chapter 34 are for the purpose of providing that the roof- ing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. . Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 29 of the SFBC. (The roof deck is usually concealed prior to removing the existing roof system.) 4 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. town- houses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occuparns of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from � below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the under- side of the decking may not be acceptable. The SFBC provides the option of maintaining this appearance. 5. Ponding Water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roof- ing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6/ 6. Overflow Scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with Chapter 23 of the SFBC. ii .7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structur- al assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider venting which can result in extending the service life for the roof. �8. The owner may contact the Miami -Dade County Consumer Services Department for further information regarding the above. Owner's/Agent's Signature 123.01 12 PAGE 2 7/99 APPENDIX "F" REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 07// i90 Date Contractor's Signature ROOF COVERING MATERIALS (TEVT) ROOFING SYSTEMS (TGFU) Continued •Base Sheet (Optional): One or more Layers Type G1, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (granule) or "Ruberoid Mop Plus" (granule). Coating: Karnak No. 97, 1 -1/2 - 3 gal /sq. 4. Deck: C -15/32 Incline: 1/2 Insulation: One or more layers pertite, glass fiber, isocyanurate, urethane, pertite/isocyanurate composite, pertite/urethane composite, phenolic. 1 -1/2 in. min thickness (offset from plywood joints 6 in.). Base Sheet: One or more layers of Type G2 or G3. Ply Sheet (Optional): One or more layers of Type 61. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Surfacing: Karnak No. 97, 1 -1/2 - 3 gal /sq. 5. Deck: NC Incline: 1/2 Base Sheet (Optional): One or more layers of Type 61, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule). Surfacing (Optional): Karnak "No. 97" or "169" at 1 -3 gal /sq or Grundy Ind. "20 F Emulsion" at 3 gal /sq. 6. Deck: C -15/32 Incline: 1/2 • Insulation: One or more layers perlite, glass fiber, 3/4 in. min, isocyanurate, urethane, perlite /isocyanurate composite, perlite /urethane composite, phenolic, 1 -1/2 in. min. Base Sheet (Optional): One or more layers of Type 61, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Surfacing: Gravel. 7. Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers pertite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic. Base Sheet: Two or more layers of Type G2 or G3. Ply Sheet (Optional): One or more layers of Type 61. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Surfacing: Karnak No. 97, 1 -1/2 - 3 gal /sq or gravel. 8. Deck: NC Incline: 1/2 Insulation: One or more layers perlite, glass fiber, 3/4 in. min, isocyanurate, urethane, perlite /isocyanurate composite, pertite/urethane composite, phenolic, 1 -1/2 in. min. Base Sheet (Optional): One or more layers of Type G1, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Sup . L MB Aluminum Ro_ ._'l;" at 1 -2 gal /sq. r ck: C -15/32 Incline: Insulation (Optional): One or more layers pertite, glass fiber, min, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, phenolic, 1 -1/2 in. min. Base Sheet: One or more layers of Type G2 "GAFGLAS 475 Base Sheet ", hot mopped or mechanically fastened in place. Ply Sheet: One or more layers of Type 61 "GAFGLAS Ply 4 ", hot mopped in place. Membrane: "Ruberoid Mop FR" (granule). urfacing (Optional): GAF Fibered Aluminum Coating at 1 -1/2 gal /sq or emulsion at 3 gal /sq. 10. Deck: C -15/32 incliner 1/2 Insulation (Optional): One or more layers perlite, glass fiber, 3/4 in. min, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, phenolic, 1 -1/2 in. min. Base Sheet: One or more layers of Type G2 "GAFGLAS #75 Base Sheet ", hot mopped or mechanically fastened in place. - Ply Sheet: One or more layers of Type 61 "GAFGLAS Ply 4 ", or "GAFGLAS Ply 6" hot mopped in ptace. Membrane: "Ruberoid Torch FR" (granule). Surfacing (Optional): GAF Fibered Aluminum Coating at 1-1/2 gal /sq or GAF Weather Coat Emulsion at 3 gal /sq. 11. Deck C -15/32 Incline: 1/2 Insulation: Isocyanurate, 2 in, min., wood fiber, perlite or glass fiber, any thickness, hot mopped or mechanically fastened in place. Joints offset 6 in. Base Sheet: One or more layers of Type 62 "GAFGLAS #75 Base Sheet ", hot mopped or mechanicatty fastened in place. Ply Sheet (Optional): One or more layers of Type 61 "GAFGLAS Ply 4" or "Ply 6" hot mopped in place. Membrane: "Ruberoid Torch FR" (granule). Surfacing (Optional): GAF Fibered Aluminum Coating at 1 -1/2 gal /sq or GAF Weather Coat Emulsion at 3 gat /sq. LOOK FOR MARK ON PRODUCT ROOF COVERING MATERIALS (TEVT) 135 ROOFING SYSTEMS (TGFU) Continued 12. Deck: C -15/32 Incline: 1/2 Insulation (Optional): Isocyanurate, perlite or glass fiber, any thickness, hot mopped or mechanically fastened in place. Joints offset 6 in. Base Sheet: One or more layers of Type G2 "GAFGLAS #75 Base Sheet ", hot mopped or mechanically fastened in place. Ply Sheet: One or more layers of Type G1 "GAFGLAS Ply 4" or "Ply 6 ", hot mopped in place. Membrane: "Ruberoid Torch FR" (granule). Surfacing (Optional): GAF Fibered Aluminum Coating at 1 -1/2 gal /sq or GAF Weather Coat Emulsion at 3 gal /sq. 13. Deck: Nt Incline: 1/2 Insulation (Optional): Isocyanurate, wood fiber board, perlite, glass fiber, any thickness, hot mopped or mechanicatty fastened in place. Joints offset 6 in. Base Sheet: One or more layers of Type G2 "GAFGLAS #75 Base Sheet ", hot mopped in place. Pty Sheet (Optional): One or more layers of Type G1 "GAFGLAS Ply 4" or "Ply 6" hot mopped in place. Membrane: "Ruberoid Torch FR" (granule). Surfacing (Optional): "GAF Fibered Aluminum Coating" at 1 -1/2 gal /sq or GAF Weather Coat Emutsion at 3 gal /sq. 14. Deck: NC Incline: 1/2 Insulation (Optional): Isocyanurate, wood fiber board, perlite, gtass fiber, any thickness, hot mopped or mechanically fastened in ptace. Joints offset 6 in. Base Sheet: One or more layers of "GAFGLAS #75 Base Sheet ", hot mopped in place. Ply Sheet (Optional): One or more layers of "GAF GLAS Ply 4" or "Ply 6" hot mopped in place. Membrane: "Ruberoid Torch FR" (granule). Surfacing (Optional): GAF Weather Coat Emutsion apptied at 3 gal /sq or GAF Fibered Aluminum Coating at 1.1/2 gat /sq. 15. Deck: C -15/32 Incline: 1/2 Insulation (Optional): Perlite, fiber gtass, isocyanurate, urethane, perlite; isocyanurate composite or phenolic. Base Sheet: One or more layers Type G2 or G3 base sheet, hot mopped or mechanically fastened. Pty Sheet (Optional): One or more layers Type G1, hot mopped in place. Membrane: "Ruberoid Mop FR" or "Ruberoid Mop 170 FR" (granule). 16. Deck: C -15/32 Incline: 1/2 Insulation (Optional): Perlite, fiber glass, isocyanurate, urethane, perlite/ isocyanurate composite or phenolic, offset 6 in. from joints. Base Sheet: One or more Layers of Type G -2 or G -3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): One or more layers of Type G -1, hot mopped in place. Membrane: One layer of "Ruberoid Torch" or "Ruberoid Mop" (smooth). Membrane: One layer of "Ruberoid Torch FR" or "Ruberoid Mop FR" (granule) 17. Deck: NC Incline: 1>2. Insulation (Optional): Perlite, fiber glass, wood fiber, isocyanurate. urethane, perlite /isocyanurate composite or phenolic. Base Sheet: One or more layers Type G2 or G3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): One or more layers Type 61, hot mopped in ptace. Membrane: One layer of "Ruberoid Mop FR" or "Ruberoid Mop 170 FR" (granule). 18. Deck: NC Incline: 1/2 Insulation (Optional): Perlite, fiber glass, wood fiber, isocyanurate, urethane, perlite/isocya nurate composite or phenolic. Base Sheet (Optional): One or more layers of Type G -2 or G -3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): One or more tayers of Type G -1, hot mopped in place. Membrane: One layer of "Ruberoid Torch" (smooth), "Ruberoid Mop" (smooth). Membrane: One layer of "Ruberoid Torch FR ", "Ruberoid Mop FR" or "Ruberoid Mop 170 FR" (granule). 19. Deck: NC Incline: 1/2 Insulation (Optional): One or more layers of pertite, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite or phenolic, any thickness. Base Sheet: One or more plies 61 or G2, hot mopped or adhered with Karnak Chemical Co. "No. 81" or Gibson- Homan "No. 6160" cold applied adhesive at 1 -1/2 gal /sq. Membrane: One layer of "Ruberoid Mop FR" or "Ruberoid Mop 170 FR" granule), hot mopped or adhered with Karnak Chemical Co. "No. 81" or Gibson-Homan "No. 6160" cold applied adhesive at 1-1/2 gal /sq. 20. Deck: C -15/32 Incline: 1/4 Insulation: Polyisocyanurate, any thickness. Base Sheet: "GAFGLAS #75" (Type G2), mechanically attached. ,v5izo vv %Itu iu:o. ri.1 Jul 000 5ovl Mui'ihk LIFETILE PRODUCT CONTROL NOTICE OF ACCEPTANC Monier Lifetile LLC 135 NW 20 St. Boca Raton, Florida 33431 Your application for Product Approval of: Monier Lifetile LLC Villa, Capri, & RoII Tiles under Chapter 8 of the Miami -Dade County Code governing the use of Alternate Materials Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Redland Technologies, The Center for Applied Engineering, Inc., and Professional Service Ind ustries has been recommended for acceptance by the Building Code Compliance Office to be used n Dade County, Florida under the specific conditions set forth on pages 2 -14 and the standard conditicns on page 15. This approval shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or m 3ttt. facturer's plant for quality control testing. If this product or material fails to perform in the approvec m inner, the Building Code Compliance Office may revoke, modify, or suspend the use of such producl o- material immediately. The Building Code Compliance Office reserves the right to revoke this appto%al, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. ACCEPTANCE NO.: 97- 1124.16 EXPIRES: 06/25/01 Internet mail address: postmaster ©buildingcodeonline .cam Revises: 95- 0322.07 95-0 322.03 95- 0316.04 ,.LL1 :V 11tLt(A1 LJUUG METROPOLITAN DADE COUNTY, FLORI )A METRO-DADE FL',G _ER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO -DADE f LAGLER BUILDS vG 140 WEST FLAGLER S7R:ET, SUITE 11103 MIAMI. FI.DF:IDA 33130.1'363 E (305) 375.2:101 zA ( (305) 375.2108 PRODUCT .:ONTROL DIVISION (305) 375 -2102 FAX (305) 372-6399 1, 7 aul Rodriguez Product Control `supervisor TH1 IS THE COVERSHEET SEE ADDITION: L PAGES FOR SPECIFIC AND 1::ENERAL CONDITIONS BUILDING CODE COMMI I'EE This application for Product Approval has been reviewed by the Miami -Dade County Building Code Compliance Office and approved by the Building Code Committee to be used in Dade Cc yin y, Florida under the conditions set forth above. Charles Danger, P.E. Director Building Code Compliance Dept. APPROVED: 06/25/9 1 Miami -Dade County Homepage:'http: / /www.bui dir gcodeonllne com iu: o7 !AA 5U1 .)J6 MUMEK LIFE11Lh JNTER LIFETLLE LLC Product Control No.: 97- 1124.16 Monier Lifetile LLC ACCEPTANCE NO: 97- 1124.16 133 N.W. 20 St. APPROVED June 25. 1998 Boca Raton, FL. 33431 EXPIRES : June 25, 2001 NOTICE OF ACCEPTA S TANDARD CONDITIONS 1 Renewal of this Acceptance (approval) shall be considered after a renewal application leas been filed and the original submitted documentation, including test supporting data, engineer.nl; documents, are no older than eight (8) years. 2 Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approved ", :,r as specifically stated in the specific conditions of this Acceptance. 3 Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluati :n )f this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approv .t:d; c) If the Acceptance holder has not complied with all the requirements of this accept:ince, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4 Any revision or change in the materials, use, and/or manufacture of the product or pro :es,; shall automatically be cause for termination of this Acceptance, unless prior written approv :il has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5 Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, adverti :;inl; or any other purposes. 6 The Notice of Acceptance number preceded by the words Miami -Dade County, Floric:t, ;aid followed by the expiration date may be displayed in advertising literature. If any port of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7 A copy of this Acceptance as well as approved drawings and other documents, where it z pplies, shall be provided to the user by the manufacturer or its distributors and shall be avail2 ble for inspection at the job site at all times. The copies need not be resealed by the engineer. 8 Failure to comply with any section of this Acceptance shall be cause for termination t..id removal of Acceptance. 9 This Acceptance contains pages I through 15. END OF THIS ACCEPTANCE Page 15 of 15 ALL1_11 ULLKA1 4JU1b .r- ,� aga, .a. Roofing Product Contro E:.a niner .r:55 FAX 561 338 5391 MONIER LIFETILE - ALLI :ll UELRAI 4161u .4TER LLFETTLE LLC Product Control No.: 97- 1124.16 Deck Type: Wood, Non - insulated Deck Description: New construction 19 /32" or greater plywood or wood plank. SYSTEM D: Mortar or Adhesive Set Application Slope Range: 2 " :12" to 7 " :12" Note: System D is only acceptable in this slope range. For slopes in excess of 7 ":12 ", refer to System C. Underlayment: Rooting Tile: Comments: SYSTEMS (CONTENTED) Install underlayment system in compliance with Dade County A 1plication Standard PA 120. (See System Limitation #5.) Install tile in compliance with Dade County Application Standard PA 120, (See "Data for Attachment Calculations " ,included in this Approval.) 1. For re -roof applications, 15 /32" plywood is an acceptable subst : ite . Page 9 of 15 ■ ran Zuloaga, RRC Roofing Product Control Examiner ,U:55 h.-1X 5u1 3:.o 53J1 Page 10 of 15 VU \1LK L11h,'11LL .1LL1t,U LLLKA /0 LLFETILE LLC Product Control No.: )7- 1124.16 SYSTEM LIMITATIONS 1. The standard minimum roof pitch for Monier Lifetile LLC Villa, Monier Lifetile LLC Capri & Monier Lifetile LLC Roll, low profile tile shall comply with Dade County Application Siandards PA 118, PA 119 or PA 120, depending on the method of installation. 2. For nail -on applications, fasteners for mechanical attachment of tiles shall have a hear. diameter larger than that of the preformed holes in the tile. 3. System installation shall be in compliance with the system specifications outlined in this Product Control Approval. The method of attachment utilized shall provide sufficient attachn::nt resistance to meet or exceed the required resistance determined in compliance with Dade Counr Protocol PA 1 15 or PA 127. Tile profiles listed here in have been tested for both wind characterise :es and static uplift performance, therefore, attachment calculations for installation in compliance wit/. PA 1 15 or PA 127 shall be done as a 'Moment Based System'. 4. For adhesive set tile applications, a field static uplift test by a Dade County accrcdite:: tc :sting agency, in compliance with Dade County Protocol PA 106, shall be performed. 5. For tile applications, 30/90 hot mopped underlayment applications may be installed perFendicular to the roof pitch unless stated otherwise by the underlayment material manufacturer's )ualished literature. 6 Al! tiles shall bear the imprint or identifiable marking of the manufacturer's name or : c g for identification in the field. 7. Applications for roofing permits shall include a completed Section 11 of the Uniform Building Permit, a copy of manufacturer's current specifications and details, a copy of this Prcdu Control Approval and a copy of the Product Control Approval of any Roofing Component us,sd n the proposed tile application. Reference shall be made to appropriate data for the require d fire rating. 8. The applicant shall retain the services of a Dade County certified testing laboratory to maintain quality control in compliance with the South Florida Building Code and related protcc:o s. Samples taken shall be in compliance with Dade County Protocol PA 112, Appendix 'A'. 9. Fire classification is not part of this aceptance. Frank Zuloaga, RRC Roofing Product Control Examiner WJU11 iVJV r:1_1 JU1 JJ0 JJLl JNTER LLFETELZ LLC MUi\1LL L1rG11Lr PROFILE DRAWINGS MONIER LIFETILE LLC VILLA TILE Page 13 of 15 MONIER LIFETILE LLC ROLL TILE - + - � - r .iLLl :U LLLA11 Product Control No.: 91-1114.16 uloaga, RRC Roofing Product Control Examiner 1.2,1Ul4 APR - 3Q - 98 THU 3:52 PM A, B. C, . SUPPLY, , CO` INC, S. FAX NO, 1 305 751 8579 ,pr 30 -98 04:10P Polyfoam Products Inc. Sra4 ran ODUC ONTR S OTIC Polyfoam Products, Inc. 2400 Spring - Stuebncr Road Spring, TX. 77383 METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FI.AGLER BUILDING TAN Your application for Product Approval et: roLy[oam products "Polvnro AJI.16Q" Roof Tilo Adhesive under Chapter 8 of t11e Miami -Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: The Center for Applied Engineering, Inc. and Miles Laboratories Polymers Division has been recommended for acceptance by the Building Code Compliance Office to be used in Dade Cottnry, Florida under the specific conditions sec forth on pages 2.14 and the standard conditions on page 15. This approval shall not be valid after the expiration dote stated below. The Building Coda Compliance OCCce reserves the right to secure this product or material at any timc from a jobsite or manufacturers plant for quality control testing if this product or material fails to perform In the approved manner. the Building Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately, The Building Code Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of inch testing will be incurred by the manufacturer. ACCEPTANCE NO.: 98-0303.02 Renews: 96- 94Q102 EXPIRES: 04/16/01 oul Rodrigu z Product Control Supervisor APPROVED: 04/16/98 Internet mall address; postmas for ®buitdingeodoonllne.Com 1 ' PHI IS 1) NAL PA CONDITIONS IIUILDINC CODE CQMMFrFFE BUILDING CODE COMPLIANCE OFFICE METRO - DADE FLAMER BUILDING 140 WEST RAKER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 315 -2901 FAX (305) 31 -2908 PRODUCT CONTROL DIVISION (305) 375-2902 FAX (305) 372.6339 GENERAL Charles Danger, P.1!. Director Building Code Compliance Dept. Miami -Dade County This application for Product Approval has been reviewed by the Miami -Dade County building Code Compliance Office and approved by the Building Code Comnsitieo to be used in Dada County, Florida under the conditions set Will above. Momepege: hop : //www,bulldingcoueonllne.com Expires: 11/06/00 Approved: 11/06/97 PRODUCT CONTROL NOTICE OF ACCEPTANCE GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 • Your application for Product Approval of: GAF Ruberoid® Modifed Bitumen Roof Systems for Wood Decks under Chapter 8T tthe Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Dynatech Engineering, Inc., Factory Mutual Research Corporation, and Underwriters Laboratories, Inc. has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions set forth on pages 2 -60 and the standard conditions on page 61. This approval shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Building Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.: 97- 0804.14 Revises No.: 95- 1003.03 THIS IS THE COVERSHEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Office and approved by the Building Code Committee to be used,jn Dade County, Flpridi under the conditions set forth above. j % �! ,( '/ � Y / 1 Raul Rodriguez Product Control Supervisor Charles Danger, P.E. Director Building Code Compliance Dept. Metropolitan Dade County Applicant: GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING SYSTEM APPROVAL Category: Membrane Roofing System Sub - Category: Built -up Roofing Type: Modified Bitumen Sub -Type: APP and SBS Contact: William J. Woodring Director of Technical Services (973) 628- 4134 Page 2 of 61 Product Control No: 97- 0804.14 • Product Control No.: 97- 0804.14 Approval Date: November 6, 1997 Expiration Date: November 6, 2000 System Description GAF Materials Corporation has been manufacturing commercial roofing products for more than 100 years. GAF produces a wide range of roof products for built -up roofing systems. The modified bitumen products include both APP and SBS products in smooth, granule and fire rated versions. In addition. GAF offers two ply modified systems to meet the specification requirements for multilayer SBS modified specifications. GAF products are distributed through a wide network of roofing wholesale distributors throughout the South Florida area. GAF provides warranted systems over various insulated and non - insulated substrates, copies of which can be obtained from GAF and can be found in the Ruberoid Modified Bitumen Application and Specification manual published. annually. GAF roof system assemblies have been extensively tested at Factory Mutual Research Corporation and Underwriters Laboratories. GAF modified bitumen membranes have been tested in compliance with ASTM D 5147 test requirements. Frank Zuloaga, Roofing Product Control Examiner Membrane Type: SBS Deck Type 1: Wood, Non - insulated New Construction or Reroof Deck Description: 19 / 7z " or greater plywood or wood plank decks System Type A(2): Base sheet mechanically fastened. All General and System Limitations shall apply. Base Sheet: PIy Sheet: Membrane: GAFGLAS® #75, GAFGLAS #80 Ultima Base Sheet, GAFGLAS® PLY 4 ®, GAFGLAS® PLY 6 ®, GAFGLAS FlexPly' Base Sheet,GAFGLAS® STRATAVENT® Nailable, RUBEROID Modified Base Sheet or RUBEROID® 20 applied to the deck with approved annular ring shank nails and minimum 1 '/&" tin caps at a fastener spacing of 9" o.c. at the lap, 12" o.c. in two rows staggered along the center_line of the sheet in the field. (Optional) One, two, or three plies GAFGLAS PLY 4 ®, GAFGLAS® PLY 6® PIy or GAFGLAS Flex Ply 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. One or more plies of RUBEROID MOP Smooth, Ruberoid® Mop 170 FR, Ruberoid® Mop Granule, Ruberoid® Mop Plus Granule, Ruberoid® 30 or Ruberoid® 30 FR or Ruberoid® Mop FR or RUBEROID UltraCladTM SBS in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. Or, One or more plies of RUBEROID MOP Smooth, RUBEROID® Mop Granule, RUBEROID® Mop l70 FR, RUBEROID® Mop Plus Granule, RUBEROID® 30. RUBEROID® 30 FR or RUBEROID® Mop FR or RUBEROID UltraCladTM SBS in RUBEROID Modified Bitumen Adhesive at an application rate of 1 -2 gal. /sq. Surfacing: (Optional, required if RUBEROID MOP Smooth or RUBEROID 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respectively in a flood coat of approved asphalt at 60 lb. /sq.. Maximum Design Pressure: Maximum Fire Classification: Maximum Slope: Specification No.: 2. GAFGLAS Mineral Surfaced Cap Sheet in an approved asphalt at an application rate of 25 lb./sq. ± 15 %. -45 psf (See General Limitation #7) 'A'. See General Limitation #2. 2 ":12 "; See General Limitation #3. Page 22 of 61 Product Control No: 97- 0804.14 Frank Zuloaga, _ Roofing Product Control Examiner Note: All insulation shall be adhered to the anchor sheet in full moppings of approved hot asphalt within the EVT range and at a rate of 20-40 IbsJs Please refer to Metro -Dade County Roofing Application Standard PA 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down.. GAF requires either a ply of GAFGLAS STRATAVENT® perforaded laid dry or a layer of GAFTEMP® PERMALITE or wood fiber overlay board on all isocyanurate applications. Anchor sheet: Base Sheet: Ply Sheet: Membrane: Surfacing: Specification No.: Product Control No: 97 0804.14 GAFGLAS® Ply 40, PIy 6 ®, GAFGLAS Flex PIy' 6, #75 Base Sheet, GAFGLAS #80 UltimaT' Base Sheet, STRATAVENT® Nailable, RUBEROID Modified Base Sheet or RUBEROID® 20 base sheet applied to the deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered in two rows 12" in the field. Base sheet shall serve as anchor sheet for attachment of insulation Install one ply of GAFGLAS® #75, GAFGLAS #80 ULTIMA Base Sheet, GAFGLAS® PLY 4 ®, GAFGLAS® PLY 6 ®, GAFGLAS Flex PIy 6, GAFGLAS® STRATAVENT® Perforated(laid dry), RUBEROID Modified Base Sheet or RUBEROID® 20 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20- 40 lbs. /sq: (see General Limitation #4). (Optional) one or more plies GAFGLAS PLY 4 ®, GAFGLAS® PLY 6® PIy or GAFGLAS Flex PIy' 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq.. One ply of Ruberoid® Torch Smooth, Ruberoid® Torch Granule, Ruberoid® Torch Plus Granule or Ruberoid® Torch FR torch applied according to manufacturer's application instructions. (Optional) Install one of the following: 1. Gravel or slag applied at 400 Ibisq. and 300 lb./sq. respectively in a flood coat of approved asphalt at 60 lb. /sq.. 2. GAF Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. or GAF WeatherCoat® Emulsion at 3 gal. /sq. (Torch Smooth applications only) Maximum Design Pressure: -45 psf (See General Limitation #7) Maximum Fire Classification: 'A'. See General Limitation #2. Maximum Slope: 2 ":12 "; See General Limitation #3. Page 21 of 61 Frank Zuloaga, Roofing Product Control Examiner Wood Deck System Limitations: 1. Fastener spacing for anchor sheet attachment is based on a Minimum Characteristic Force (F') of 95 lbf or greater as tested in compliance with Merto -Dade County Protocol PA 105. If F' as tested is below 95 lbf, a professional engineer may submit a revised fastener spacing utilizing the withdrawal resistance value taken from Merto -Dade County Protocol PA 105 and calculations in compliance with Metro -Dade Roofing Application Stanadrd PA 117. 2 All standard insulation panel sizes are acceptable for mechanical attachment. When panels are applied in hot asphalt, maximum panel size shall be 4' x 4'. a. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') of 275 Ibf. as tested in compliance with Merto -Dade County Protocol PA 105 & Roofing Application Standard PA 117. If the fastener value, as field tested, are below 275.1bf. insulation attachment shall not be acceptable. 3 A slip sheet is required with GAFGLAS FlexPly 4® and Ply 6® when used as a mechanically fastened base or anchor sheet. 4. '/2 Type X gypsum board is acceptable to be installed directly over the wood deck.. Page 57 of 61 Product Control No: 97- 0804.14 Frank Zuloaga, Roofing Product Control Examiner GENERAL LIMITATIONS Product Control No: 97- 0804.14 1 All asphalt shall comply with ASTM D 312 type III or type IV requirements, and approved by applicant. 2 Fire ratings are determined by a combination of slope, deck type and assembly. Refer to current Underwriters Roofing Materials Directory or other fire testing data listed in the testing file. Fire ratings shall be in strict compliance with Sections 3401.5 and 3401.6 of the South Florida Building Code. • 3 Maximum slope range shall vary for each system; consult current Underwriters Laboratories Roofing Materials Directory and manufacturer's specifications for compliance with design criteria for each project. 4 An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used, install one layer of GAFGLASS STRATAVENT Perforated, laid dry.A base sheet may be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. Where STRATAVENT Perforated is used over approved isocyanurate foam insulation, the maximum design pressure is limited to —60psf. 5 All work shall be performed by a contractor licensed to do roofing work in Metro -Dade County. Contractor shall be familiar with the details and specifications published by the manufacturer, and the requirements of the SFBC. 6 The submission of system specifications and details shall accompany the Section II Building Code Permit. This information is available in the publications listed in the 'System Description' of this Product Control Approval. The submission of these documents, as well as the proper application and installation of all materials shall be the sole responsibility of the contractor. Page 58 of 61 0 111411 ran Zuloaga, Roofmg Product Control Examiner Product Control No: 97- 0804.14 7 Perimeter and corner areas shall comply with the enhanced uplift pressure of these areas, as calculated in compliance with Chapter 23 of the South Florida Building Code. Fastener densities shall be increase for both insulation and base sheet as needed calculated in compliance with Metro -Dade County Roofing Application Standard PA 117. (When this limitation is specifically referred within this NOA, General Limitation #20 will not be applicable.) 8 All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Metro -Dade County Roofing Application Standard PA 111 and the wind load requirements of Chapter 23 of the South Florida Building Code. 9 Flashings shall be installed according to the manufacturers standard details, and may be applied in cold application adhesive, approved asphalt or may be applied in conjunction with an approved torch applied modified bitumen membrane. Specific details, approved by the manufacturer, shall be submitted with the Section II Permit Application. All details shall comply with the provision of the South Florida Building Code. 10 Fastener spacing for base sheet attachment is based on a Minimum Characteristic Force (F') value as tested in compliance with Metro -Dade County Protocol PA 105. If the fastener values as tested are below those listed in the System Limitations, a professional engineer may submit a revised fastener spacing utilizing the withdrawal resistance value taken from a Metro - Dade County Protocol PA 105 test report and calculations that comply with the wind load requirements of Chapter 23 of the South Florida Building Code and Roofing Application Standard PA 117. 11 Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with PA 105. If the fastener value, as field tested, are below 275 lbf. insulation attachment shall not be acceptable. 12 Asphalt moppings shall be with applied with approved asphalt and shall be in compliance with equiviscous temperature (EVT) methods of asphalt determination. Asphalt containers or bulk tickets shall indicate an EVT, finished blowing temperature (FBT) and flash point. Asphalt types and temperature ranges shall be in compliance with Subsection 3403.4(a)(3) of the South Florida Building Code. 13 Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq., or mechanically attached using the fastening pattern of the top layer. Refer to manufacturer's literature and/or the NRCA Roofing and Waterproofing Manual for correct application procedures of insulation panels in approved asphalt or adhesive, which shall comply with provision of Roofing Application Standard PA 117 / Page 59 of 61 rank Zuloaga, Roofing Product Control Examiner Page 60 of 61 Product Control No: 97 -0804.14 14 All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 15 In re- covery/re- roofing applications, prior to the application, all existing roof surfaces used as a bonding substrate shall be tested in compliance with Metro -Dade County Protocol PA 124 for uplift resistance. Test pressures shall be calculated in compliance with the wind load requirements of Chapter 23 of the South Florida Building Code to the design pressure of the roof. 16 In re- roofing applications, moisture content in an existing roof must be in compliance with Section 3401.10(m), (n) of the South Florida Building Code. 17 Roll good materials shall be stored on end and on a clean, flat and dry surface. 18 If required, any Factory Mutual Approved vapor barrier in conjunction with proprietary or approved adhesives may be used prior to the application of the insulation layer. 19 Consult current Underwriters Laboratories Directory for the appropriate coating for each roofing assembly to obtain the required fire rating. The assembly shall be installed in strict compliance with sections 3401.5 and 3401.6 of the South Florida Building Code for maximum fire classification. 20 The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, corners). No rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners, and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) Frank Zuloaga, --_ Roofing Product Control Examiner Product Control No: 97- 0804.14 GAF Materials Corporation ACCEPTANCE NO.: 97- 0814.14 1361 Alps Road APPROVED: November 6.1997 Wayne, NJ 07470 EXPIRES: November 6, 2000 1 NOTICE OF ACCEPTANCE STANDARD CONDITIONS Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2 Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Metro -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3 Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4 Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5 Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6 The Notice of Acceptance number preceded by the words Metro -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7 A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer. 8 Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9 This Acceptance contains pages 1 through 61 END OF THIS ACCEPTANCE Page 61 of 61 Frank Zuloaga, ----- Roofing Product Control Examiner GEOTECHNICAL ENVIRONMENT.AL HYDROGEOLOGY ASBES1)S Miami, August 31, 2000 Mr. Ron Lucien ATLAS ROOFING 5011 NW 37 Avenue Tamarac, FL Dear Mr. Lucien: Test No. 01 -61F 62 -78P 79 —88 C i r i . __ 111/MIW 1a. DYNATECH ENGINEERING CORP. Re: Permit No.: 111 13 , Existing Residence @ 1237 NE 93` Street Miami, FL TESTING LABORATORIES DRILLING SERVICES INSPECTION SERVICES ROOFING In accordance with your authorization, DYNATECH ENGINEERING CORP., performed an uplift test in compliance with protocol PA -106 and the South Florida Building Code on August 31, 2000 at the above referenced project. Dynatech Engineering Corp., is a Certified Dade County Testing Agency. The purpose of our inspection was to determine the uplift capacity of the existing roof tiles for the one -story residence at the above referenced project. The subject roof consisted of a Spanish "S" roof tiles polyfoam set. On August 31, 2000 our field engineer visited the site and conducted (88) uplift test on the roof tiles at the locations indicated on the attached sketch. All tests were performed according to the South Florida Building Code Section 3404.3 and protocol PA -106 using a Humboldt scale model H -4620. The following is a summary of results: Field Test Results are: Test Location See Attached Diagram See Attached Diagram See Attached Diagram Field Uplift Pull Test > Than 40 LBS > Than 40 LBS > Than 40 LBS Test Result Passed Passed Passed 750 West 84 Street, Hialeah, FL 33014 -3618 ° Phone (305) 828 -7499 ° Fax (305) 828 -9598 Page No. 2 1237 NE 93` Street Test results were found in compliance with the South Florida Building Code and Protocol PA- 106. Pursuant to section 7.3.2. of PA -106 a copy of this report shall be forwarded to the building official for his final roof top inspection. The test results are limited to the tested areas. If other roof areas exhibit different conditions, it should be brought to our attention for remedial work. This uplift test is not a roof top inspection. A final roof inspection must be conducted by the building official for approval. The test results presented here, reflect the condition of the roof system at the time of the test. These results are time and sample dependent since roof conditions are continuously changing due to exposure to the elements. It has been a pleasure working with you and look forward to do so in the near future. Sincerely yours, S I R un Wissam Naamani, P.E. DYNATECH ENGINEERING CORP. Florida Reg. No. 39584 Special Inspector No. 757 WN /no ? • 5 ?g-u- Sfec4 Dynatech Engineering Corp. Client: ATLAS ROOFING Project: 1237 NE 93rd Street, Miami, FL Scale: N.T.S. Date: O& 3 ( Op