Loading...
SHUTTER PERMITPERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date /1 / Job Address ( r/ $/ e. 9 a r Tax Folio Legal Description Historically Designated: Yes • Owner/Lessoe / Tenant )j ,SKJaL' zoi N,,:c, . frie.td sct .�,e, Master Permit # Phone ,( 3o5 7.r - ? 9 7 6 Contracting Co. x t2 4 s. C re r i /;red - mac . Address PO, ieo x 66/06, I ` Q72v sX. ctt Owner's Address 1/ 9 / . 9a- s Tn e e i SS# Phone 7o3 999- 866y State # 111 s- //a Municipal # �/g Competency # AdS 0 is Ins. Co. v, u, ue CPptr Architect/Engilneer "JAL Address Bonding Company i/i . Address Mortgagor /---)//> Address • Qualifier _✓i eti Permit Type (circle one WORK DESCRIPTION ry Square F a Estimated Cost (value) "6 YoO. o WARNING TO OV /PIER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YO FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE I'OR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. Signature of owner and/or Condo President t/91 a as to My Commissi ei' ? SCOTT i- iAI -ThT .,6 • J, FEES: PERMIT Fes My Comm Exp. 10/21 ice.i115 No. CC5u4475 11 r'VNBnaJy'known t1Qtht RADON ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN (et ✓.1cla/..'L ckt ilekt 7 � A.)f -km taf,o�- ,pr�re(r — A cco vt cif 'o•�r — C.C.F. NOTARY ignature of Contractor or Owner -B ' der SC - TT 1T/ 7. 'arr • :. ,'23759 c11i' Z3�Vrier-Biiilddrihs xpirg: • . , ,l oueri.Da BOND at 97 APPROVED: TOTAL DUE Zoning Building Mechanical Plumbing Structural Engineer fr (f?r Electrical NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT t` O. TAX FOLIO NO. l / ` 3,.� 0 - p O 3 w3 STATE OF FLORIDA: COUNT`r OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property. and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: 1 i /V s 8 : , Lo �z 2. Description of improvement: 3. Owner(s) name and address: Sf^ /rl .�1 / fib' /v C / q IZ St.tec NCI f /Hyni SNJvteJ ! = L Interest in property: p w ,r e vL Name ard address of fee simple titleholder: 1 pn'1 2 4. Contractor's name and address: 2 6.S it ti t9P2flfz/ s esr .±' J C. ✓ /10/ 6 6106d- 114i J /=C 3 3, 6 G. 5. Surety:(Payment bond required by own r from contractor, if anhilERF31 0 i]na Name and address: Amount of bond $ 6. Lender's name and address: Name and address: nature of Owner Print Owners Name T,+s -3/atc A H✓ CDnC 7. Persc ns within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: Sec% 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a differe t.dete is specified) UI� Sworn :o and subscribed •or rta, thi i id T�+Ne. 19 _x_ '0T i ' d M }' Ccrr: r 10;23199 c � Bonded 13y S ;ice 1119 Nn r'C:5!1; 75 Notary Public Print NDtary's Name S CO-Tr /4PrIAPL'en.Lv x„ow„ MONZA / STATE, OF FLORIDA, COUNTY 0 DADE CERHFY 1',0' this is a fru co le w HA V Went — Lltie ti/Atlov+eli'vNl E.' Q, n , nd RUVIN CLE 99R302224- 1999 JUN 10 12:29 n o`lice on 0 f`icial Seol. , A 0 19 Address: of th a y of of Circuit and County Courts D.C. 68C .1C c Prepared by: f on S/w t rZ P.0.110)( 66. 1OJ I)1/'m j�/Jvfi .. r'C 3 a6 ( General Hurricane Shutter Manufacturing, Corp. 9605 N.W. 79 Avenue • Bay # 7 • Hialeah Gardens 33016 Tel.: (305) 557 -7778 Shutter Product Approval Authorization Form ACCEPTANCE No.: ,99-0317.01 DATE: 6:2/7 �y BUILDING O FICIAL: MUNICIPALITY: tvi i nit,' ADDRESS: ;4/1/ /).A 41 �c i.P"(.c DEAR: d� We are the Dade County 1: ce of Acceptance Holder for Aluminum type shutters approved undo x,: 99- 0317. This Letter Authorizes r. Q S. c- 1 evE p,-t,Jae . �� to use our accordion type s- hutter approved under '99- -0317.01, to be used at the following job: NAME: .sc t,weidec sfr1s ,n y ADDRESS: (f I CITY: ill , '"? • .Ss tlohP, Number of Shutter: /3 Square feet of Shutter: ind erely Jose A. Zuri ga President Florida Storm Panels 14475 N.W. 26 Avenue • Opa- locka, FL 33054 • (305) 685 -9990 • (305) 685 -9000 • FAX (305) 685 -7511 SHUTTER PRODUCT APPROVAL AUTHORIZATION FORM Building Offical Dear Building Official: We are Dade County Notice of Acceptance holder for the .060 Aluminum panels under number 96- 0304.1. This letter authorizes R 6 S L„jPv.�Jrr'f`�' to use our .060 aluminum panels approved under number 96- 0304.01 to be used at the following job: Sincerely, Victor V. Cruz Or Enriq evil' President Vice - President Florida Storm Panels, Inc. 1 This form must accompany the application for building permit and shall become part of the permit documents. 2. The authorized signature must bear the raised corporate seal of the company holding the Dade County Notice of Acceptance. G� �0 44171 DR0S4Lo NM P.O. 8 o a C50900 3 MAW SOMMS, vg, agalg Qsoz 30 -2504 PROOSI (I MOM cJ �e d ect am / 7/� / II Qi /mac 6/)- stA4J y 0 ( = r � 0 & L e _ 7 s _ 3 ( �/ o � 7s 7 (L iw i.0 ' c- I 00 .tJ , c[o eta, G� �o MIZA OG ISgS, /1 Y . O.O. 80:g 009002 MAW SPNIOC4S. =goo Q .300XICC -C604 YNOSMIT NA AS S c k i-p i " ck fr\ . OMIT 6 • 7 9 � i I v t Svc= , ►a sT ,keeT y 0 "3 :3`7% v e - 1 A LP v, t-t 'o- xj* C� ✓,1ti'o.' cC vp..,g11 sa -77 X_ � l c 0,0 1 )--,i A- c ctz v d,' 7 3- ME�.DADE METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING PRODUCT CONTROL NOTICE OF ACCEPTANCE Genf ral Hurricane Shutter Corp. 9605 N.W. 79 Ave., Bay 7 Hialeah Gardens FL 33016 BUILDING CODE COMPLIANCE OFFICE SUITE 1603 METRO DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 INTERNET: mdcc01@shadow.net PRODUCT CONTROL SECTION (305) 375 -2902 FAX (305) 372 -6339 Your application for Product Approval of: ASSA/Residential Bertha Accordion Shutter under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This approval shall not be valid after the expiration date stated below. BCCO reserves the right to secure this produci . or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such product or material immediately. BCCO reserves the right to revoke this approval, if it is determi zed BCCO that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.: 99-0317.01 Expires:04 /13/2002 Raul Rodriguez Chief Product Control Division THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL This application for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Dade County, Florida under the conditions set forth above. Approved :04/13/1999 CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE aoh, rancisco Quintana, R.A. Director 1 of 3 Miami -Dade County Building Code Compliance Office General Hurricane Shutter Corp. ACCEPTANCE No.: 99- 0317.01 APPROVED APR 1 3 1999 EXPIRES APR 1 3 2002 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS 1 Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documents, including test - supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a. There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes. b. The product is no longer the same product (identical) as the one originally approved. c. If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product. d. The engineer, who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and /or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a. Unsatisfactory performance of this product or process. b. Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The engineer needs not reseal the copies. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Notice of Acceptance consists of pages 1, 2 and this last page 3. END OF THIS ACCEPTANCE Helmy A. Ntakar, P.E.- Product Control Examiner Product Control Division 3 of 3 METRO -DADE PRODUCT CONTROL NOTICE OF ACCEPTANCE Florida Storm Panels /Stainless Metalworks, 14475 N.W. 26th Avenue Opa Locka FL 33054 Your application for Product Approval of: .060" Aluminum, 3003 -H14 Alloy, Storm Panel Strutter under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: .4pplicant, along with Drawing No. 95 -549, Sheets 1 thru 4 of 4, (for listing , see Section 8 of this Notice of Acceptance) has been recommended for acceptance by the Building Code Compliance office to be used in Dade County, Florida under the specific conditions set forth on pages 2 et. seq. and the Standard Conditions cn page 3. This approval shall not be valid after the expiration date stated below. The Office of Code Compliance reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The afplicant shall re- evaluate this product or material should any ammendments to the South Florida Building Code be enacted affecting this product or material. The Building Code Compliance Office reserves the thi right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.:96- 0304.01 Expires:07 /11/99 THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. Approved:07 /11/96 -1- METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE SUITE 1603 METRO DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 INTERNET: mdcc01@shadow.net PRODUCT CONTROL SECTION (305) 375 -2902 FAX (305) 372 -6339 Rau Ro• iguez Product Control Supervisor Director Building Code Compliance Dept. Metropolitan Dade County Fl61rida Storm Panels, Inc. ACCEPTANCE NO.: 96- 0304.01 APPROVED : JUL 1 1 1996 EXPIRES : JUL 1 1 1999 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 1. DESCRIPTION 1.1 This approves a .060" aluminum, 3003-H14 alloy , storm panel designed to comply with the South Florida Building Code, 1994 Edition for Dade County, for the locations where the pressure requirements as determined by ASCE 7 -88 "Minimum Design Loads for Buildings and Other Structures ", do not exceed the Design Pressure Rating values in Section 7 and within the limitations contained in Section 3. 2. MATERIAL CHARACTERISTICS 2.1. The storm panels shall be constructed as indicated on approved drawing No. 95 -549, Sheet 1 of 4, using .060" thick aluminum, alloy 3003-H14. 2.2 Panels are rolled formed, have a nominal width of 12 -1/2" and a total full width of 14 -1/2 ", forming 2" deep ribs 2.3 Components shall be aluminum alloys 6063 -T6, "H" headers, "U" header, 1-1/2"x 1-1/2"x 1/8" sill angle and 2" x 5 "x 1/8 ", 2" x 5 "x 1/4" built -out angles. 2.4 Tested specimen: Dimensions: 4 panels 52" wide x 101" long overall. 4 specimens for windload 4 panels 52" wide x 67" long overall. 1 specimen for windload 4 panels 52" wide x 48" long overall. 1 specimen for windload 4 panels 52" wide x 101" long overall. 4 specimens for impact and cyclic load 4 panels 52" wide x 104" long overall. 2 specimens for impact and cyclic load 3. LIMITATIONS �.1 The design will be dependent on the maximum panel height of 7' -2" or 86 ", for wall mount with bottom sill continuous wood or aluminum tube ledger as shown on drawing No. 95 -549, Sheets 2 of 4. 3.2 Minimum separation to existing glass to protect shall be 3" with stitch bolts reinforcement as shown on Sheet 1 of 4. 2 -1/4" with reinforcing bar (Part 16) as shown on Sheet 1 of 4. 3..3 Maximum clearance between top of panel and inside of header shall he 1/4" 3. t Special Requirement: Reinforcing bar, consisting of one 1" x 1" x 16 Ga. Galy. Steel tube (Part 14) attached with I/4 " -20 x 3 -1/2" long SS bolts with wingnut assemblies spaced 12 -1/2 "" o.c at panel midspan overlaps; or one (1) row of 1/4 " -20 x 1" long SS stitch bolts reinforcement with wingnuts assemblies spaced 12 -1/2" o.c. at panel midspan overlaps. Panel overlap spans less than 33" do not require midspan reinforcement bars and /or stitch bolts. -2 Orla do Blanco, P.E. - Plans Examiner 11 Product Control Division k'luridla §term Panels. Inc. -2a- Al:CEI' I AiNt_:I4, NO.: 90 -U io.0 I APPROVED EXPIRES NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS r ill!. 1 1 1996 :JUL 1 1 1999 4. INSTALLATION 4.1 The panels shall be installed only in the following condition: 4.1.1 Wall Mounts: (A) (CONCRETE /MASONRY): The panels are secured to an '1 -1' Wall Header (Parts 2 or 3) at the head and attached with 1/4"-20 S.S. studs spaced 6-1/4" o.c. to a 1-1/2" x 1-1/2" x 1/8" aluminum angle at the sill (Part 7), both the header and sill angle are anchored to the wall, using the tension anchors as shown on Section A "Wall Mount Section "; or the panels are directly secured to the wall using approved tension anchors as shown on Sections F "Wall Mount Section (Direct Mount) ", as shown on Drawing No. 95 -549, Sheet 2 of 4 ; or panels attached at the head and sill to a continuous 'F' track (Part 9) with 1/4 " -20 x 1" S.S. studs spaced 6 -1/4" o.c. , the track is then secured to the wall using approved tension anchors as shown on Sections I "Wall Mount Detail ", as shown on Drawing No. 95 -549, Sheet 3 of 4 bearing the Dade County Product Control approval stamp. (B) (WOOD FRAMED): The panels are secured to an '1 -1' Wall Header (Parts 2 or 3) at the head and attached with 1/4"-20 S.S. studs spaced 6-1/4" o.c. to a 1-1/2" x 1-1/2" x 1/8" aluminum angle at the sill (Part 7), both the header and sill angle are anchored to the wall, using the tension anchors as shown on Section D "Wall Mount Section "; or at the sill , panels are attached to a continuous 2 x 6 PT wood ledger or 1" x 4" x 1/8" or 2" x 4" x 1/8" aluminum tube ledger plate with 1/4" diameter S.S. lag screws spaced 11" o.c. and #14 SMS at midway between lag screws, the ledger plate is then anchored to the wall with (2) - 1/4" diameter S.S. lag screws spaced 24" o.c. maximum, as shown on Sections E "Wall Mount Section (Bottom) ", as shown on Drawing No. 95 -549, Sheet 2 of 4, or panels attached at the head and sill to a continuous 'F' track (Part 9) with 1/4 " -20 x 1" S.S. studs spaced 6 -1/4" o.c. , the track is then secured to the wall using approved tension anchors as shown on Sections I "Wall Mount Detail ", as shown on Drawing No. 95 -549, Sheet 3 of 4 bearing the Dade County Product Control approval stamp. 4.1.2 Ceiling/Inside Mounts: (A) (CONCRETE /MASONRY): The panels are secured to an 'U' 1-leader (Part 4) at the head and attached with 1/4"-20 S.S.studs spaced 6-1/4" o.c. to a 1-1/2" x 1-1/2" x 1/8" aluminum angle at the sill (Part 7), both the header and sill angle are anchored to the wall, using approved tension anchors as shown on Section B "Ceiling /Inside Mount Section ", Drawing No. 95 -549, Sheet 2 of 4, bearing the Dade County Product Control approval stamp. (B) (WOOD FRAMED): The panels are secured to an 'U' 1- leader (Part 4) at the head and attached with (3) #14 wood S.M.S. wood screws with minimum of 2" penetration or (3) wood brushings with 1" penetration at each rafter or truss thru a 1 "x 5 "x 1/8" continuous channel (Part 11) or 1 "x 4 "x 1/8" continuous aluminum tube; at the sill the panels are attached with 1/4" S.S. studs spaced 6 -1/4" o.c. to a 1 -1 /2 "x 1 -1 /2 "x 1/8" aluminum sill angle (Part 7), the sill angle in then anchored with approved tension anchors, as shown on Section G "So it Mount Detail ", Sheet 3 of 4 , Drawing No. 95 -549, bearing the Dade County Product Cone .� al stamp. rT ndo Blanco, P.E. - Plans Examiner II Product Control Division fkkrida Storm Panels, Inc, NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 4.1.3 Built -Out Condition: (A) (CONCRETE /MASONRY /WOOD FRAMED): The panels are secured to an 'U' Header (Part 4) at the head, which is attached to built -out angles (Parts 5, 5A, 5B or 6), with 1/4"-20 S.S bolts spaced 12" o.c., and a 1-1/2"x 1 -1 /2 "x 1/8" aluminum studded angle (Part 7) at the sill, which is attached to built -out angles (Parts 5, 5A, 5B or 6), w ith 1/4 " -20 S.S. bolts spaced 12" o.c., both of the built -out angles are then anchored to the wall using approved tension anchors as shown on Section C "Built -Out Mount Section ", Sheet 2 of 4; or Section H "Alt. Build -Out Mount Section ", Sheet 3 of 4; Drawing No. 95 -549, bearing the Dade County Product Control approval stamp; or the panels are secured to an 'H' Header (Parts 2 or 3) at the head, which is attached to built -out channel (Part 10), with 1/4"-20 S.S bolts spaced 12" o.c., and a l -1/2"x 1-1/2"x 1/8" aluminum studded angle (Part 7) at the sill, which is attached to built -out channel (Part 10), with 1/4 " -20 S.S. bolts spaced 12" o.c., both of the built -out channels are then anchored to the wall using approved tension anchors as shown on Section J "Built -Out Mount Section ", Sheet 4 of 4 , Drawing No. 95 -549, bearing the Dade County Product Control approval stamp. 4.1.4 Storm Panel Interior Fastening: Panel are secured at sill using component angles (Part 5A and 7) as shown on Detail J "Storm Panel Interior Fastening (Isometric) ", Sheet 3 of 4, Drawing No. 95 -549, bearing the Dade County Product Control approval stamp. 4.1.5 Any combination of the above, 4.2 Anchorage of the shutters shall be to concrete, masonry and /or wood framing and shall consist of only the anchors specified on drawing No. 95 -549, Sheets 1 thru 4 of 4. Substitution of anchor type or indicated embedment is unacceptable. 4.3 Fasteners must have their own Notice of Acceptance and must be made of stainless steel or have adequate protection against corrosion, per DIN 50018. Aluminum contacting metals not considered compatible shall be properly protected. 4.4 Permanent set fastener components, embedded anchor bolts, threaded cones or metal shields, not in use, must be protected against corrosion, contamination and damage at all tinge. 5. IDENTIFICATION 5.1 Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Dade County Product Control Approved ". 5.2 Also a Warning Note shall be permanently stamped in each panel advising the home owner or tenant that the storm panels will not offer hurricane protection unless all reinforcing bolts are properly installed. - 2b - ACCEPTANCE NO.: 96- 0304.01 APPROVED EXPIRES Product Control Division 'JUL 1 1 1996 : :JUL 1 1 1999 J Orlando 1 ico, P.E. - Plans Examiner II TEST TEST LOAD DESIGN LOAD Deflection LARGE MISSILE IMPACT TEST SFBC PA 201 -94 (Stitch Bolt Reinforcement) SATISFACTORY CTC -95 -036 Max. 3 " LARGE MISSILE IMPACT TEST SFBC PA 201 -94 (Aluminum Bar Reinforcement) SATISFACTORY CTC -95- 036 Max. 2 -1/4" CYCLIC WIND PRESSURE TEST 3FBC PA 203 -94 POSITIVE (101" Span) +68.0 PSF CTC -95 -036 +52.3 PSF CTC -95 -036 CYCLIC WIND PRESSURE TEST ;FBC PA 203 -94 NEGATIVE (101" Span) -98.8 PSF CTC -95 -036 -76.0 PSF CTC -95 -036 UNIFORM STATIC AIR PRESSURE TEST S.;FBC PA 202 -94 POSITIVE (101" Span) +75.0 PSF CTC -95 -036 +50.0 PSF CTC -95 -036 @ Design 1.165 UNIFORM STATIC AIR PRESSURE TEST SFBC PA 202 -94 NEGATIVE (101" Span) -93.0 PSF CTC -95 -036 -62.0 PSF CTC -95 -036 LNIFORM STATIC AIR PRESSURE TEST SFBC PA 202 -94 NEGATIVE (67" Span) - 226.03 PSF CTC -95 -036 - 150.68 PSF CTC -95 -036 UNIFORM STATIC AIR PRESSURE TEST SI PA 202 -94 NEGATIVE (48" Span) -442.0 PSF CTC -95 -036 - 294.67 PSF CTC -95 -036 DESIGN PRESSURE RATING: See "STORM PANEL SCHEDULE "; Table 1, Sheet 4 of 4, Drawing No. 95 -549 Florida Storm Panels, Inc, ACCEPTANCE NO.: 96- 0304.01 7. TESTS PERFORMED TESTS: -2c- RESULTS: APPROVED EXPIRES NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS : 1 111 1 1 1996 :' JUL 1 1 1999 6. USE 6.1 Application for building permit shall be accompanied by two copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Completely dimensioned drawing showing size and location, including height above grade, of openings to receive shutters; mean roof height, length and width of building. 6.1.3 Duplicate prints of approved drawings No. 95 -549, Sheets I thru 4 of 4, bearing the approval stamp, Notice of Acceptance number and date by Dade County Product Control Section, clearly marked to show the components selected for the proposed installation. 6.2 The Building Official shall ensure the adequacy of shutter to meet the pressure requirement of the opening in which it is to be installed r ando Blanco, P.E. - Plans Examiner 11 Product Control Division k7ori�la §tornn Panels. Luc, ACCE I'ANC :1'; NO.: o10 ;U4.11I APPROVED : I JUL 1 1 1996 EXPIRES : JUL 1 1 1999 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 8. EVIDENCE SUBMITTED 8.1 Tests: 8.1.1 Test report on: Uniform Static Air Pressure Test Impact Test Cyclic Wind Load Test prepared by Construction Testing Corporation, Report No. CTC -95 -036, dated November 14, 1995, signed and sealed by Christopher G. Tyson, P.E. 8.2 Drawing: 8.2.1 Drawing No. 95 -549, Florida Storm Panels, Inc. Storm Panel , Sheets 1 thru 4 of 4 prepared by Knezevich & Associates Inc., dated 01/04/96, Revision No. 2, dated 06/06/96, signed and sealed by V.J. Knezevich, P.E. 8.3 Material certification: 8.3.1 Mill Certified Inspection Reports issued by MSC Metals, dated 09/29/95. 8.3.2 Certified Tensile Test Report issued by QC Metallurgical, Inc., QCM Job No. 5KM -2636, dated November 15 „1995, signed and sealed by James Roese, P.E. 8.4 Calculations: 8.4.1 Comparative analysis and anchor calculations, dated 12/i 8/95, prepared by Knezevich & Associates Inc., signed and sealed by V.J. Knezevich, P.E. -2d- , _ Orlando i lanco, P.E. - Plans Examiner II Product Control Division f orida Storm Panels, Inc. ACCEPTANCE NO.: 96- 0304.01 . JUI 1 1 1996 'JUL 1 1 1999 APPROVED EXPIRES NOTICE OF' ACCEPTANCE: STANDARD CONDITIONS 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documents, including test supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manuf'acturer's name, city, state, and the following statement: "Dade County Product Control Approval ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The copies need not be resealed by the engineer. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Acceptance contains pages 1, 2, 2(a) through 2(d) and this last page 3. Items 10. 11 & 12 listed below only appy to glazed products and doors 10. Unless specifically indicated in the Acceptance (approval), this unit is approved as a single unit installation. For multiple installation of this unit, a separate Acceptance for mullions is required from the Product Control Section. I I . The spacing of fasteners at window sills shall be as indicated in Section 4 of this Notice of Acceptance. The spacing of fasteners in all other parts of the frame, shall be as indicated in Section 4 of this Notice of Acceptance, but in no case shall exceed 24" on center. The first fastener shall be located at a maximum of 6" from each corner and mullion or stile. Fastener shall fully penetrate the buck, which shall be the same size as the one tested with the unit. No wood or plastic shields or pins shall be used for anchoring. 12. Hardware for all windows and doors shall conform to Security and Forced Entry Proven on ► apter 36 of the South Florida Building Code. Orl '. L lanco, P.E. - Plans Examiner 11 Produ t Control Division ENI) OF TIIIS ACCEPTANCE PRODUCT CONTROL NOTICE OF ACCEPTANCE Hirst Awning Co., Inc. 5795 N.W. 36 Avenue Miami Yoor application for Product Approval of: Bahama Shutter under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Typ:s of Construction, and completely described in the plans, specifications and calculations as submitted by: Appiicant. (For listing, see section 8 of this Notice of Acceptance.) has been recommended for acceptance by the Building Code Compliance office to be used in Dade County, Florida under the specific conditions set forth on pages 2 et. seq. and the Standard Conditions on ptlge 3. This approval shall not be valid after the expiration date stated below. The Office of Code Compliance reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The applicant shall re- evaluate this product or material should any ammendments to the South Florida Building Code be enacted affecting this product or material. The Building Code Compliance Office reserves the the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such tasting will be incurred by the manufacturer. Acceptance No.:98 -0213.06 Expires:02 /27/01 FL 33142 Raul Ro IMF guez Product Control Supervisor TIIIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. ' Approved:03 /19/98 -1- Internet ma l address: postmaster @buildingcodeonline.com METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING COPE CO1APLIANCE OFFICE METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI. FLORIDA 33130 -1563 (305) 375 - 2901 FAX (305) 375 -2908 PRODUCT CONTROL DIVISION (305) 375 -2902 FAX (305) 372 -6333 1 - s anger, Director Building Code Compliance Dept. Metropolitan Dade County Homepage: ht tp: / /www.buildingcodeonline.com I-Iurst Awning Co., Inc. ACCEPTANCE No; : 9 — 8-0213.06 APPROVED : MAR 1 9 1998 EXPIRES F � NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 27 2001 1. DESCRIPTION This approves an aluminum bahama shutter designed to comply with the South Florida Building Code, 1994 Edition for Miami -Dade County, for the locations where the pressure requirements, as determined by SFBC chapter 23, do not exceed the Design Pressure Rating values in Section 7 and within the limitations contained in Section 3. 2. MATERIAL CHARACTERISTICS The bahama shutter and its components shall be constructed in strict compliance with approved drawing No. 94 -187, with revision #4, titled Bahama Shutter; Hurst Awning Co., Inc., prepared by Knezevich and Associates Sheets 1 and 2 of 2, bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. These plans shall hereinafter be referred to as the approved plans. 3. LIMITATIONS All permanent set components, included but not limited to embedded anchor bolts, threaded cones, metal shields, headers and sills, must be protected against corrosion, contamination and damage at all time. 4. INSTALLATION This hurricane protection system must be installed in strict compliance with the approved plans. 5. IDENTIFICATION Each panel shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ". 6. USE 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Duplicate drawing No. 94 -187, revision #4, titled Bahama Shutter; Hurst Awning Co., Inc., prepared by Knezevich and Associates Sheets 1 and 2 of 2, bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division, clearly marked to show the components selected for the proposed installation. 6.1.3 Any other documents required by the Building Official or the South Florida Building Code (SFBC) in order to properly evaluate the installation of this system. 6.2 This document renews Notice of Acceptance No. 95-0113.02 dated March 23, 1995. Manu I Perez, PE, Produ Product Control Division ntrol f xamincr TEST _ TEST LOAD D DESIGN LOAD D D FLECTION LARGE MISSILE IMPACT TEST S _ T 1 urst Awning Co., Inc. ACCEPTANCE No. 98 -0213.06 APPROVED 1998 EXPIRES • February 27, 2001 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 7. TESTS PERFORMED 8. EVIDENCE SUBMITTED 8.1 Tests: 8.1.1 Previously Submitted Information: 8.1.1.1 Test report on Large Missile Impact Test and Cyclic Wind Pressure Test of bahama shutters, prepared by Hurricane Engineering & Testing, Inc., Report No.HETI -94 -377, dated Nov. 17, 1994, signed and sealed by Hector M. Medina, P.E. 8.1.1.2 Test report on Uniform Static Air Pressure Test of bahama shutters, prepared by Hurricane Engineering & Testing, Inc., Report No. HETI -94 -373, dated Nov. 15, 1994, signed and sealed by Hector M. Medina, P.E. 8.1.2 Drawing: 8.1.2.1 Drawing No. 94 -187, "Bahama Shutter ", Sheets 1 and 2 of 2, prepared by Knezevich and Associates, Inc., dated 11/29/94, rev. 112 dated 01/23/95, signed and sealed by V.J. Knezevich, P.E. 8.1.2.2 Die Drawing No. GAS -42150 of extruded louver blade. 8.1.3 Material certification: 8.1.3.1 Mill Certified Inspection Report issued by INDALEX dated Dec. 13, 1994 with chemical composition and physical properties of alum. alloy 6063 -T6 for louver blade Part No. GAS - 42150. 8.1.3.2 Certified Tensile Test Report No. HETI 94 -T45, for colonial and bahama shutter specimen, prepared by Hurricane Engineering & Vesting, Inc., dated.' 1/29/94, per ASTM E8 -93, signed and sealed by Hector M. Medina, P.E. 8.1.4 Calculations: 8.1.4.1 Anchor analysis and calculations dated 01/06/95, Pages 1 thru 4 of 4, prepared by Knezevich and Associates, Inc., signed and sealed by V.J. K.nezevich, P.E. Manu .Iterez, PE, Produ )ntrol Examiner Product Control Division -2a, u'rst Awning Co., Inc. ACCEPTANCE No.:: 98- 0213.06 APPROVED MAR 9 1998 EXPIRES Februa27 2001 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 8.2 New Evidence Submitted 8.2.1 Drawing: 8.2.1.1 Drawing No. 94 -187, "Bahama Shutter ", Sheets 1 and 2 of 2, prepared by Knezevich and Associates, Inc., dated 11/29/94, rev. #4 dated 02/20/98, signed and sealed by V.J. Knezevich, P.E. 8.2.2 Calculations: 8.2.2.1 Anchor analysis and calculations dated 02/10/98, Pages 1 thru 4 of 4, prepared by Knezevich and Associates, Inc., signed and sealed by V.J. Knezevich, P.E. -2h- Manu 1 Perez, PE, Product Product Control Division trol Examiner • Sout [tern Aluminum Mk., Inc. NOTICE OF ACCEPTANCE: STANDARD CONDITIONS Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documents, including test - supporting data, engineering documents, are no older than eight (B) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approval ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. S. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The engineer need not reseal the copies. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Acceptance contains pages 1, 2, 2(a) through 2(b), and this last page 3. Items I D, I I & 12 listed below only apply to glazed products and doors 10. Unless specifically indicated in the Acceptance (approval), this unit is approved as a single unit installation. For multiple installation of this unit, a separate Acceptance for mullions is required from the Product Control Section. I I . The spacing of fasteners at window sills shall be as indicated in Section 4 of this Notice of Acceptance. The spacing of fasteners in all other parts of the frame, shall be as indicated in Section 4 of this Notice of Acceptance, but in no case shall exceed 24" on center. The first fastener shall be located at a maximum of 6" from each corner and mullion or stile. Fastener shall fully penetrate the buck, which shall be the same size as the one tested with the unit. No wood or plastic shields or pins shall be used for anchoring. See section four (4) of this approval for sizes of fasteners used in testing. 12. Hardware for all windows and doors shall conform to Security and Forced Entry Prevention, Chapter 36 oldie South Florida Building Code. Manuel erez, PE, Product Co jr r l'roduc antral Division END OF THIS ACCEPTANCE -3- ACCEPTANCE No. : 98 -0202.01 APPROVED : M 1 9 1999 EXPIRES FEB 2 7 2001 - /i... Examiner