Loading...
RF-10-1794Inspection Number: INSP - 152155 Scheduled Inspection Date: December 02, 2010 Inspector: Bruhn, Norman Owner: TUTIVEN, JACQUILINE Job Address: 1130 NE 92 Street Miami Shores, FL Project: <NONE> Contractor: QUALITY ROOFING CONTRACTORS INC Building Department Comments REROOF Passed Failed Correction Needed Re- Inspection Fee December 01, 2010 No Additional Inspections can be scheduled until re- inspection fee is paid. Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspector Comments For Inspections please call: (305)762 -4949 Permit Number: RF -10 -10 -1794 Permit Type: Roof Inspection Type: Final Roof Work Classification: Flat Phone Number Parcel Number 1132050270430 Phone: 305 - 751 -0382 Page 8 of 22 RE:Permit# RF- 10— )oa11 01 _00 f0 iko (Print name and circle License Type) License #: 00 0 0 11 5 0 On or about 00 . 23, �o�o (Date & time) secondary water barrier work at Miami Siote4tillafe 'l4 Defuntaseat 10050 NE 2 Ave Miami Shores, FI 33138 Phone 305-795-2204; Fax 305-756-8972 www.miamishoresvillage.com INSPECTION AFFIDAVIT �3 dyof DATE: , licensed as a (n) Contractor / Engineer / Architect, FS 468 Building Inspector , I did personally inspect the roof deck nailing and /or 1110 13 --CL. c a 3*e cfr (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) Signature State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he /she is the contractor for the above property mentioned. Sworn to and subscribed before me this Notary Public, Sate of Florida at Large 2-0/o NOTARY PUBLIC -STATE OF FLORIDA " Marylou Hernandez ; ` :- Commission #DD930046 pins: OCT. 10, 2013 BONDED THRU ATLANTIC BONDING CO., INC. 468 F.S. to make such an inspection. *General, Building, Residential, or Roofing Contractors or any individual certified un Include photographs of each plane of the roof with permit # and address # clearly shown marked on the deck for each inspection A RECORDED PERMIT NO. STATE OF FLORIDA COUNTY OF MIAMI -DADE: CFt 2O1 ORO678 74 NOTICE OF COMMENCEMENT OR ; k 27445 P9 21381 (1pg ) COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTIONR GORGED 10/06/2010 ,1 :52:0 I T ' RVEY IRUVIHr CLERK OF COURT U ANI -GAGE COUNTYY FLORIDA TAX FOLIO NO.1 1- 3205 - 027 -0430 L 5T PAGE THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Lega` description of property and street / address: •1130 N.E. 92 Street 2. Description of improvement 3. Owner(s) name and address: 1130 N.R. 92 Streit Miami Shores, Fl 33138 Interest in property: Owner Name and address of fee simple titleholder. 4. Contractor's name and address: Quality Roofing Contractor, Inc. 5. Surety: (Payment, bond required by owner from contractor, if any) - Name and Address: N/A STATE t F FLORIDA, QOUNTY Of CAOE r - Amount of bond $ n n 1HEREBYCbI 4'roaritasis cett ca 6. Lender's name and address: original filed in Mrs offics on 7. Persons within the state of Florida designat provided by Section 713.13(1)(a)7., Fiori Name and Address: N/A 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Uenor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and Address: N/A 9. Expiration ate of this different date 's s • = died) 4Igndt of Owner Paint Owner's Name Reroof to a new Mineral Can sheet roof. Jacquiline L. Tutiven 13800 N.W. 1st Avenue Miami, Fl 33168 le e 6:011-G( 1Ve Sworn to and subscribed before me this Notary Public: Print Notary's Name: ission x • ires: Commencement (the expiration date is 1 year from the date of recording unless a NU JAM rundCiTATE 0 N/A 2 day `Commission #DD930046 Expires; OCT.10, 2013 EAU ATLANTIC BONDING CO., 11W. Miami Shores. Fl 33138 10 111111111111111111111111111 1 prepared by Marylou Hernandez ®e - , 20 /P Quality Roofing Contractor Address: 1 3Rnn N W 1st AVPrine Miami. PI 33168 (Inc) 951 -1111 BUILDING PERMIT APPLICATION FBC 20 Miami Shores Village Building Department Permit Type: BUILDING ROO Owner's Name (Fee Simple Titleholder) Jacquiline L . Tutiven Owner's Address 1130 N.E. 92 Street City Miami Shores State F1 Tenant/Lessee Name Email Job Address (where the work is being done) 1130 N. E. 92 Street City Miami Shores Village County FOLIO /PARCEL# 11- 3205 - 027 -0430 Contractor's Company Name Quality Roofing Contractor Contractor's Address 13800 N. W.' 1 st Avenue City Miami State Fl Qualifier Name Carlos Arocho State Certificate or Registration No. 1C 0 0 5 8 6 2 7 Contact Phone Carlos or Marylou Value of Work For this Permit $ 18 , 0 00.0 0 10050 N.E.2nd Avenue, Miami'Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit No. EF /O 1,4K Master Permit No. Training/Education Fee $ Notary $ Scanning $ Radon $ DPBR $ Double Fee $ Violation date: Miami -Dade Zip 33138 Phone # Phone # ( 786) 387 Zip 33138 Is Building Historically Designated YES NO y Flood Zone Phone # (305) 953 -3333 Zip 33168 Phone# (786) 367 -2029 Certificate of Competency No. 000017889 E - mail qualityroofing88 @yahoo.com Architect/Engineer's Name (if applicable) Phone # Square / Linear Footage Of Work: 3 50 0 s g f t. Type of Work: ['Addition ['Alteration [New ® Repair/Replace ❑ Demolition Describe Work: Reroof to a new Mineral Cap sheet roof with insulation. ******** * * * * * * * * * * * * * * ** * * * ** * * * * * * * * ** F * * * * * * * * * * * * * * ** ** * * * * * * * * * * * ** Submittal Fee $ Permit Fee $ � CCF $ CO /CC $ Technology Fee $ Bond $ Structural Review. $ Total Fee Now Due $ See Reverse side - Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK , PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. • • certified copy of the recorded notice of commencement must be posted at the job site fo r the first inspection wh• h occur seven (7) days er the building permit is issued. In the absence of such posted notice, the inspection will not be appro d and reinspection fee 'll be charged. The foregoing instrument was acknowledged before me this o/ day of a. . , 20 /: 0 , by ' , to L ;V v t , who is persona]] known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: ***** * * *3r3e9e*4Y4e9e***9e9r*** * drk********* kk 9e*3c3r*9e9e3c**** *3r* 9e9e9e3e9rsY9r*a***k dr4r3e9edrie***** *****k: Ydr*Bede9e ,Y9e9c3r9e***Fir **k*** ** APPROVED BY G %°�% J/d23' Plans Examiner Zoning (Revised 07 /10 /07)(Revised 06/10/2009) NOTARY PLBLI 4.TATE OF FLORIDA '''''''' M. ' ou Hernandez ,' Commission #DD930046 '•,,,;,,, Expires: OCT. 10, 2013 BONDED THRII ATLANTIC BONDING CO., INC Engineer Contractor The foregoing instrument was acknowledged before me thisv2 day of 0 � , 20 /0 by e „cio, c�� , who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: TE OF Commission on # D930046 •• Expires: OCT. . 10, 2013 1�O RP TaRD ATLANTIC BONDING CO, INC Clerk checked To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: Jacquiline L. Tutiven Property Address: N.E. 92 Street Miami Shores, Fl 33138 Roofing Permit Number: Dear Building Official: Jacquiline L. Tutiven building because: tx The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of Signature Notary Public, Sate of Florida at Large Revised on 5/21/2009 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. Building Code (1994 SFBC) Swom to and subscribed before me this day O When the just valuation of the structure for purpose of ad valorem taxation is equal to or more tha SFBC. Then you must provide a building application from a General Contractor for the Roof to W Miami Shores Viiiage Building Department Date: 8/13/2010 certify that I am not required to retrofit the roof to wall connections of my ZC9`7,a_ e v.- vt Print Name 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. ®r w acr® NOTARY PUBLIC -STATE OF FLORIDA Marylou Hernandez ) Commission #DD930046 Expires: OCT. 10, 2013 BOARD THRU ATLANTIC BONDING CO., INC. 0,000.00, and the building was not constructed with FBC nor a 1994 connection Hurricane Mitigation. SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES - REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. - . er's initial in the designated space indicates that the item has been explained. 1. Ilitni etics•Workmanship: the workmanship provisions of Section R4402 are for the purpose of p roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the asli" -it between the owner and the contractor. • filed 1'• •;Y al •I an Ex p from erto cy roofing s "-Overfl ded from N . no of the Q v1 -ve n Signature enailing wood decks: When replacing roofing, the existing wood roof deck may have to be • - ��• rdance with the current provisions of Section R4403. (The roof deck is usually concealed prior to re w e existing roof system). " Its (i. owner pene appe c di e origi overfl ac co redu roof. Owner/Agen Revised on 7/9/2009 LD • mmon roofs: Common roofs are those which have no visible delineation between neighboring wnhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or notify the occupants of adjacent units of roofing to be performed. • sed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can • low. The owner may wish to maintain the architectural appearance; therefore, roofing nail e underside of the decking may not be acceptable. This provides the option of maintaining the ding water. The current roof system and/or deck of the building may not drain well and may nd (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural y require the review of a professional structural engineer. Pounding may shorten the life performance of the new roofing system. Pounding conditions may not be evident until the m is removed. Pounding conditions should be corrected. w scuppers (wall outlets): It is required that rainwater flows off so that the roof is not uildup of water. Perimeter /edge wall or other roof extension may block this discharge if rss (wall outlets) are not provided. It may be necessary to install overflow scuppers in the requirements of Sections R4402, R4403 and R4413. lation: Most roof structures should have some ability to vent natural airflow through the bly (the building itself). The existing amount of attic ventilation shall not be beneficial to sider additional venting which can result in extending the service life of the / oidit Contractor Signature Date LDG DEPT COMPLIANCE WITH ALL FEDERAL Inc - AND COUNTY RULES AND REGULATIONS Florida Building Code Ed HIGH Velocity Hurricane Zone Uniform Pe General In Master permit No. Process No. Contractor's Name • . t • • - ' _� Job Address 1130 N.E. 92 Street Low Slope O Asphaltic Shingles 3500sqft. location of parapets. ROOF CATEGORY ❑ Mechanically. Fastened Tile❑ Mortar /Adhesive Set Tile O Metal PaneUShingles 0 Wood Shingles/Shakes . 0 Prescriptive BUR -RAS 150 ROOF TYPE ❑ New Roof 12 Re- Roofing ❑ Recovering ❑ Repair ❑ Maintenance ROOF SYSTEM BNFORMATI N Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF)` N/A 3500sqft. Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. include dimensions of sections and levels, clearly Identify dimensions of elevated pressure zones and ■IIMME■ EMMMMMMM■ M ■M■MMMMM<MMMMn<MMMM■MMMMMMMM■■ ■■■■■■■■■■■■!M■■■■MEM■■■M IIMM■■■MMEM •■■■■■■■■ ■I•■■ MIMMEMMEMOMEMMEMMENWOMMEMOmmummadMIIMMEMMEMMINIM ■■■■■■■■■■ litimmilmummomm mmim•o>•>> AIIM■■■■■■■■■■ ■ ■■■■ ■ ■i• ■ ■Il illMM M■■ M ■■■■ ■■M■M ■MM ■MMMIIMM ■ ■MMM■■■ ■M■ MMIIMMEMININM MEMMINIMMAMMEMMEMEMEMMEMOUMEMEMMEMMEM ■■■■■■■■■■ I■>.■■ ■:::ai■■■■ ■MM■■i>yM■■M■M■ ■■MM■■ ■MMM ■ ■MMMEM ■■■ i ■■MM■M■MMMIMMMM■ ■MM ■MM■ ■ ■■ ■■M■■MM iii ■■■ SI■■■ ■■ ■■ ■MIMMMM■■MuiiiiM ■M■■M ■■■■M■ ■■■■■MMM■Mra M■■. i■■ M■ ■■■■rIMMM■MMM■M1u1!MM■■M■■ ■■ ■■■ ■■MM ■ ■M■■M!M M■ r i . I MMM ■■■■■u�■■■■MM■M�riM■ ■■■■■■■■■■■ M ■ ■ ■ ■ ■ ■ ■ ■ ■ ■M ■ I ■ ■■Mn�1 ■■ialimmom �•• M■■■■i•■ ■ ■■■ ■■ ■ ■ ■ ■ ■ ■M ■ ■11M ■Mllf'' I■■ M ■ ■i ■ ■t1■ ■ ■ ■■ ■■i• ■M■■■ ■MM■ ■ ■MMM■ ■M■■ ■ ■M■■ 't�.. IM■! 1■]■■ ■ ■ ■ ■ ■■il ■ ■ ■■M ■ ■ ■ ■ ■ ■ ■M ■M ■■ ■■■ ■ ■■ ■■ ■MM■■■■ �f■■■ EMMM ■■M■MII ■MM■ ■M■ ■MM ■MM■ ■M ■M■ ■MM■ ■■ ■■■■■■ ' M M■■ W .M ■ ■ ■ ■ ■ ■■M■ ■ ■ ■■ ■■■■■■■ ■■■ ■■M■MM■M■M■I•■M■Ih1SZ , « �: 1[1M■ ■ ■■M■MM ■r ■ ■ ■ ■M■■ ■ ■ ■ ■■ ■■■■■■■■■■MAMM MEM■ MMMII■■MMMM■ ■MMMMMMMM ■MM■ ■M■ ■■ ■M ■MM■ ■IUM■ ■•I ■ ■M■■ ■11■■■ ■MM ■MM■MM■MMM■M■■ ■M■ ■■■■■MMM■■MMEM■ N ■■■■■■HINIMM■M■M■M■■■■ ■M■■ ■■■M■ ■ M■ ■■ ■M.■Miil•MM % ■■MMEMII■■■■■MUMMOMM ■MM ■■ ■ ■■M■ ■■■■■■■■■■ MAMM•Iti MEMM ■■■!111■ ■■M ■M ■t•■■■■■■ ■M■■■■■■■ ■■■■■■■■■■■Ippni muumMII1■■■■■■■■■■■■■■ ■MM■■■■■■ ■M■■MM ■■M■ MGM ■ ■M ■M■ ■Y ■M■ ■M■MM ■■■■■■■M■■■■■■■ ■■■■■■■■■■■■ rMM■ ■ ■MM■■MMMM■MMMMMMMMM ■M■■ ■■MM ■M■ ■■ MM■■ M■ M■■■■■ M■ ■M ■M■■MMMMMMM■ ■M■ ■MM■■■EMM■■ ■M■ ■■■■■■■■■■■■■■■■ ■MM■■ ■■M ■M■■■■MMM■■ ■M■ ■I■■■■■■■ Section C (Low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA ") System Manufacturer:GAF Material Corporation Product Approval No.: 07 - 1219.09 Design Wind Pressures, From RAS 128 or Calculations: Pmax1: -49.2 Pmax2: - 82.6 Pmax3: -124.3 Max. Design Pressure, from the'specific Product Approval system: _R2 Deck: Type: Wood GaugelThickness: 1 X 6 Slope: .5 Anchor /Base Sheet & No. of Ply(s): (1) 75 base Anchor /Base Sheet Fastener /Bonding Material: 1 1/4" R/S nails Insulation Base Layer: 1 Base Insulation Size and Thickness: 1" Base Insulation Fastener /Bonding Material: Type= 111 marring asphalt Top Insulation Layer: N/A Top Insulation Size and Thickness: N/A Top Insulatio Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): N/A Base Sheet Fastener /Bonding Material: N/A Ply Sheet(s) & No. of Ply(s): (2) pli of ply 4 Ply Sheet Fastener /Bonding Material: Type 111 mopping asphalt Top Ply: (1) Layer MTnera 1 C.; ip Rhit Top Ply Fastener /Bonding Material: Type 111 mopping asphalt FLORIDA BUILDING CODE — BUILDING Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. Field N/A ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Surfacing: N/A Fastener Spacing for Anchor/Base Sheet Attachment: Field: 9 " oc @ Lap, # Rows 2 @_9_" oc Perimeter: 6 " oc @ Lap, # Rows 4 @ 6 "oc Comer: 6 " oc @ Lap, # Rows A___@ _ �" oc Number of Fasteners Per Insulation Board: Perimeter N/A Comer N/A Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener • Type, Fastener Sp g or Submit 6111 C6Q r. f `n i - ‘ c c e -7-e./ ' '10 ‘ -f2-44 i L L dviTt- Parapet Mean Roof Height BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as desdribed herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built-Up Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 03- 0501.05 and consists of pages 1 throygh 19. The submitted documentation was reviewed by Jorge L. Acebo. MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 1 of 19 ROOFING SYSTEM APPROVAL Category: Sub - Category: Deck Tyne: Maximum Design Pressure TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Leak BusterTM MatrixTM 307 Premium Asphalt Primer GAF Mineral Shield"' Granules Leak BusterTM MatrixTM 305 Fibered Asphalt Emulsion Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating LeakBusterTM MatrixTM 322 Elastomeric Roof Coating LeakBusterTM MatrixTM Select Asphalt Emulsion Fibered 306 Leak BusterTM MatrixTM 204 Wet/Dry Roof Cement RUBEROID Modified Bitumen Flashing Cement LeakBusterTM MatrixTM 201 Premium SBS Flashing Cement GAFGLAS #75 Roofing BUR Wood -75 psf Test Dimensions Specification 3, 5, 55 gallons ASTM D 41 60 & 100 lb. bags 5 gallons 1, 5 gallons 55 gallons 55 gallons 1, 5 gallons 5 gallons 5 gallons ASTM D 1863 ASTM 1227 Product Description Asphalt concrete primer used to promote adhesion of asphalt in built -up roofing. Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral Shield"' Granules shall be used for flashing applications only. Surface coating for smooth surfaced roofs. ASTM D 2824 Fibered aluminum coating. Elastomeric roof coating. Asphalt emulsion fibered. ASTM D -4586 Refined asphalt blended with a mineral ASTM D-3409 stabilizer and fibers. Permits adhesion to wet and dry surfaces. ASTM D 4586 Fiber reinforced, polymer modified Flashing cement ASTM D 4586 Asphalt flashing Cement 39.37" (1 meter) ASTM D 4601 Asphalt impregnated and coated glass mat wide base sheet. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 2 of 19 Product GAFGLAS #80 ULTIMATA Base Sheet GAFGLAS Flex P1yTM 6 GAFGLAS Ply 4 GAFGLAS Mineral Surfaced Cap Sheet GAFGLAS EnergyCapTM Mineral Surfaced Cap Sheet GAFGLAS STRATAVENT EliminatorTM Perforated GAFGLAS® Flashing GAFGLAS STRATAVENT EliminatorTM Nailable RUBEROID SBS Heat We1dTM Smooth RUBEROID SBS Heat- We1dTM Granule RUBEROID SBS Heat- We1dTM 170 FR RUBEROID SBS HeatWeldTM PLUS RUBEROID ® SBS H PLUS FR RUBEROID SBS Heat- We1dTM 25 RUBEROID Modified Base Sheet Dimensions 3937" (1 meter) wide 3937" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide Various 39.37' (1 meter) wide 1 meter (39.37 ") wide 1 meter (3937 ") wide 1 meter (39.37") wide 1 meter (3937 ") wide 1 meter (39.37") wide 1 meter (39.3T') wide 39.37" (1 meter) wide Test Specification ASTM D4601, ASTM D 2178 ASTM D 2178 ASTM D 3909 ASTM D 3909 ASTM D 4897 D 3672 ASTM D 4897 D3672 • ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D-6164 ASTM D4601, Type II, UL Type G2 BUR Product • Description Asphalt impregnated and coated, fiberglass base sheet Type VI asphalt impregnated glass felt with asphalt coating. Type W asphalt impregnated glass felt with asphalt coating. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules with factory applied layer of TOPCOAT Fiberglass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. Asphalt coated glass fiber mat flashing sheet available in three sizes. Fiberglass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Non -Woven Polyester mat coated with polymer- modified asphalt and smooth surfaced. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with . polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with polymer - modified asphalt and smooth surfaced. Premium glass fiber reinforced SBS modified base sheet NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 3 of 19 Product RUBEROID 20 RUBEROID Mop Granule RUBEROID Mop Plus (Granule) RUBEROID® MOP Smooth RUBEROID MOP 170FR RUBEROID MOP FR RUBEROID TORCH Smooth RUBEROID TORCH Granule RUBEROID TORCH PLUS (Granule) RUBEROID TORCH FR RUBEROID ® 170FR TORCH RUBEROID 30 RUBEROID 30 FR RUBEROID ULTRACLAD RUBEROID Dual FR Vent Stacks (metal and plastic) Dimensions 3937" (l meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 3937" (1 meter) wide 39.37" (1 meter) wide 3937" (1 meter) wide 3937' (1 meter) wide 39.37" (1 meter) . . wide 39,37' (1 meter) wide 39.37" (1 meter) Wide 39.37" (1 meter) wide 39.37" (1 meter) wide 3937" (1 meter) wide 3937" (1 meter) Wide Test Product Specification IDescriution ASTM D 6163 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6164 ASTM D 5147 ASTM D 6164 ASTM D 5147 ASTM D 6164 ASTM D 5147 ASTM D 5147 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6163 ASTM D 5147 ASTM D 6163 ASTM D 5147 ASTM D 6298 ASTM D 5147 ASTM D 6164 ASTM D 5147 TAS 100(A) ASTM D 1929 ASTM D 635 SBS modified asphalt base sheet and interply sheet reinforce with a glass fiber mat. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with polymer - modified asphalt and smooth surfaced. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, smooth surface. Asphalt impregnated, coated felt, surfaced with mineral granule. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, granule surface. Heavy duty, polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule surface. Heavy duty, polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule surface. Non -woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven fiberglass mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Woven fiberglass mat coated with Polymer modified asphalt and surfaced with aluminum, copper or stainless steel foil. Non -woven polyester and fiberglass mat coated with file retardant, polymer modified asphalt and surfaced with mineral granules. One way valve vent used to relieve built-up pressure within the roof system. GAF Vent Stacks are available in metal or plastic. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 4 of 19 Product Leak BusterTM MatrixTM 302 Non Fibered Aluminum Roof Coating GAF Built -Up Roofing Asphalt RUBEROID MOD Asphalt, Asphalt L & Asphalt P Leak BusterTM MatrixTM 602 Leak BusterTM MatrixTM 715 LeakBusterTM MatrixTM 531 WeatherCoteTM SeamCotem FireOutTM VersaShield VersaShield FB -1S VersaShield FB -2S TOPCOAT FireShield MB Leak BusterTM MatrixTM 201 SBS Flashing Cement Leak BusterTM MatrixTM 102 SBS Adhesive Leak BusterTM MatrixTM 202 SBS Flashing Cement Leak BusterTM MatrixTM 203 Plastic Roof Cement Leak BusterTM MatrixTM 103 Cold Process Adhesive Dimensions 5 gallons 1001b. cartons, bulk 60 lb. kegs 5 gallons 5 gallons 2 gallons 2, 5 gallons 5, 55 gallons 350 sq ft. roll 350sg ft. roll 350 sq ft. roll 5, 55 gallons 5 gallons 5 gallons 5 gallons 5 gallons 5 gallons Teat Specification ASTM D2824, Type I ASTM D312, Types I, II, III and IV proprietary ASTM D-412 ASTM D -21 -96 ASTM D1475 ASTM E -1644 ASTM D3019 ASTM D3019 ASTM D4586 ASTM D4586 ASTM D3019 Product Description Non - fibered aluminum pigmented, asphalt roof coating. Interply mopping and surfacing asphalt. SEBS modified asphalt. Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Elastomeric roofing membrane. Low VOC, fire barrier coating. Non - Asphaltic Fiberglass -Based Underlayment. Non - Asphaltic Fiberglass -Based Underlayment. Non - Asphaltic Fiberglass -Based Underlayment. Elastomeric roofing membrane Cold Applied Modified SEBS Asphalt Adhesive — Flashing Grade. Cold Applied Modified SEBS Asphalt Adhesive. Cold Applied Modified SEBS Asphalt Adhesive — Flashing Grade. Standard Plastic Asphalt Roofing Cement Cold Applied Asphalt Adhesive. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 5 of 19 Product Leak BusterTM MatrixTM 303 Fibered Aluminum Roof Coating Leak BusterTM MatrixTM 304 Non Fibered Aluminum Roof Coating APPROVED INSULATIONS: Product Name EnergyGuardTM RA, RN Composite A & N EnergyGuardTM Fiberboard EnergyGuardTM Permalite EnergyGuardTM GAFCANITM EnergyGuardrM Permalite Recover Board EnergyGuardTM Tapered Edge Strip EnergyGuardTM Perlite EnergyGuardTM High Density Fiberboard EnergyGuardTM Composite EnergyGuardTM Composite RA Wood Fiber High Density Wood Fiberboard Perlite Insulation Dens Deck ® , Dens Deck Prime, Dens Deck Dura GuardTM Structodek SecurockTM Dimensions 5 gallons Test Specification ASTM D 2824 Fibered aluminum coating. gallons ASTM D2824, Non-fibered aluminum pigmented, asphalt Type I roof coating. Table 2 Product Description: Polyisocyanurate foam insulation Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insulation. Fiberboard insulation. • Perlite insulation board. Cut perlite board Perlite recover board Tapered perlite board Perlite insulation board High density wood fiberboard insulation. Polyisocyanurate /wood fiberboard composite Polyisocyanurate/wood fiberboard composite Wood fiber insulation board Wood fiber insulation board Perlite insulation board Water resistant gypsum board Wood fiber insulation board Fiber reinforced roof board Product Description, Manufacturer (With Current NOA) BMCA ' GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. BMCA BMCA generic generic generic G -P Gypsum Corp Knight Celotex USG Corporation NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 6 of 19 APPROVED FASTENERS: Fastener Number 1. IRT of S. Fl. MIAMbDADECOUN Product Name Drill -TecTM #12 Standard, #14 and #15 extra Heavy. Duty Fastener , Heavy Duty Roofing-Fastener 2. Drill -TecTM ASAP 3. Drill -Teem #12 or 4#14 Standard screws with AccuTrac Plate 4. Drill -TecTM Galvalume Plates • 5. Drill -TecTM Polypropylene Plates 6. Drill-TecTM AccuTrac Plate EVIDENCE SUBMITTED: Test Agency Factory Mutual Research Corp. PRI Asphalt Technologies, Inc. APPROVED TABLE 3 Product Description Insulation fastener and Base Play fastener for steel, wood & concrete decks. Pre- assembled Drill- TecTM Fasteners and metal awl plastic plates.. Base sheet fastening assembly. Round Galvalume stress plates. Round polypropylene stress plates. Square Galvalume coated steel plate. Test Identifier J.I. 2B8A4.AM J.I. 3B9Q1.AM J.I. OD0A8.AM J.I.ODIA8.AM J.I. OY9Q5.AM 3029832 GAF - 012 -02 -02 GAF -020 -02 -01 02 -005 02 -014 Manufacturer Dimensions (With Current NOA) Various GAF Materials Corp. Various QAFXS0 PPP Various GAF Materials Corp. 3" and 3 W GAF Materials Corp. 3" and 3 %z" GAF Materials Corp. 3" Square GAF Materials Corp. Description 4470 4470 4470 4470 -TAS 114 4470 - TAS 114 4470 -TAS 114 Physical Properties ASTM D 4977 TAS 114 TAS 114 . Date 07.02.97 01.08.98 07.09.99 07.29.94 04.01.98 05.11.07 11.06.01 02.01.02 01.18.02 03.22.02 NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 7of 19 APPROVED ASSEMBLIES Deck Type 1I: Wood, Insulated • Deck Description: 19 / 32 " or greater plywood or wood plank System Type A: Anchor sheet mechanically fastened, all layers of insulation adhered with approved asphalt. All General and System Limitations shall apply. One or more layers of any of the following insulations. . Insulation Layer (Table 2) . Insulation Fasteners Fastener (When applicable: Steel plate only =S, plastic plate only (Table 3) Density /ft P) EnergyGuardTM, EnergyGuardTM Composite, EverGuard ISO,EnergyGuardTM RA, EnergyGuardTM RA Composite Minimum 1" thick N/A N/A EnergyGuardTM High Density Wood Fiber, EnergyGuardTM Recover Board, Wood Fiber, Minimum 'A" thick N/A N/A EnergyGuardTM Perlite Minimum %" thick N/A N/A Fiberglas (Min. 15 /16" thick) Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs /100 ft Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation- listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS STRATAVENT EliminatorTM Perforated laid dry or a layer of EnergyGuardTM Perlcte or wood fiber overlay board on all isocyanurate applications. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield ® Non - Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. • Anchor sheet: TIMATM Base Sheet, STRATAVENT® EliminatofTM • le, UBE ' " G `o ® Modified Base Sheet, RUBEROID 20, RUBEROID Heat- WeIdTM Smooth or RUBEROID Heat- WeIdTM 25 base sheet mechanically fastened as described below; Fastening Options: GAFGLAS Ply 4, GAFGLAS Flex P1yTM 6, GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure -45 psf,, See General Limitation #7) N/A • N/A NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 8 of 19 Fastening Options: GAFGLAS Ply 4, GAFGLAS Flex P1yTM 6, GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS Flex PlyTM 6, GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure 52.5 psf, See General Limitation #7) GAFGLAS #80ULTIMATM, RUBEROID 20, RUBEROID Mop Smooth, base sheet attached to deck with approved 11/4" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows - staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure —60 psf, See General Limitation #V GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with Drill - TecTM #I2 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psi, See General Limitation #7) Any of above Anchor sheets attached to deck approved annular ring shank nails and 3" inverted Drill -TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill-TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation 1#7) Base Sheet: (Optional) Install one ply of GAFGLAS'' #75, GAFGLAS #80 ULTIMATM Base Sheet, GAFGLAS STRATAVENT EliminatorTM Perforated, RUBEROID Modified Base Sheet, RUBEROID Mop Smooth, RUBEROID 20 RUBEROID Heat- WeIdTM Smooth or RUBEROID Heat- We1dTM directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq; (see General Limitation #4). Ply Sheet .One or more plies GAFGLAS PLY 4, GAFGLAS Flex PIyTM 6 sheet, #80 Ultima, RUBEROID Mop Smooth or RUBEROID 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs./sq. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 , Approval Date: 03/20/08 Page 9 of 19 Cap Sheet: (Optional) One ply of GAFGLAS Mineral Surfaced Cap Sheet or GAFGLAS EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: (Optional, required if RUBEROID MOP Smooth or RUBEROID 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 Ibs.sq. and 300 Ibs./sq. respectively in a flood coat of approved asphalt at 60lbs.sq. or applied in a flood coat of Leak BusterTM Matrix"' 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs.sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM MatrixTM 715 , Leak BusterTM Matrix"' 322, TOPCOAT MB +, TOPCOAT Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 galisq. Maximum Design Pressure: See Fastening above. 5. Leak BusterTM MatryxTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT Surface Seal, TOPCOAT Fireshield SB Solvent based Elastomeric Roofing Membrane applied at Ito 1.5 galisq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 10 of 19 WOOD DECK SYSTEM LINIITATIONS: 1 A slip sheet is required with PIy 4 and Flex P1yTM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 1 /a" Dens DeckTM or ' /Z" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 Ibs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested incompliance with Testing Application Standard TAS 105. If the fastener value, as field- tested, are below 275 Ibf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter hailers, metal profile, and/or flashing termination designs shall conform with Roofmg Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10.. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 19 of 19 03/23/2009 14:22 3057518579 ABC MIAMI 2007 ROOFING MATERIALS AND SYSTEMS DIRECTORY 122 ROOF COVERING MATERIALS (TEVT) Roofing Systems (TC;FU)-- Cortfi eed Base Coat 'A -3B Series ", 0,75 gal /aq. Second base Coat "A-38 Series ", 0.75 gal /sq, Wear Coat " A-38 Series ", 0.75 gal /sq plus walnut shells at 025 lbs per sq. surfacing: " A -38 Series ", 0.75 gaI /sq plus walnut shells at 0.75 Ibe per 46 D k: NC Incline: 3/4 Foam: Spray application of 2 -in. thick ° Polyfoam 273' (2.7lb /ft. ) Stufadng: Spray application of 28 to 34 -mils "U -8730" (aluminum) 47 Deck: NC Incline 1 /2 Insulation: Spray application of 2 -in. thick "Pnlyfoam 273" (2.7 lb /fL Surfacing* Spray application of 28 to 34 -mils "U- 8782 ". (ivory) GAF MATERIALS CORP 11.306 1361 ALPS RD, WAYNE NJ 07470 "Ruberoid 20" or "Ruberoid Modified Base Sheet" may be utilized as an alternate to Type G2 base sheets in any of the following Classifcatons. 1/2 in. thick (min) gypsum board or 1/4 in. thick (min) C3-P m G psu DertsDecke may be use in any existing noncombustible deck Class if:�tation. when this is done, the resulting roofing ystem is acceptable for use over " combustible (15/32 in. min) roof decks. The joints in the Hsu board and overly enl board are offset 6 in. with the joints in the deck. If gypsum is e part of the roof system, it must be placed below the overlayment Board. Also, multiple plies of "GAFGY,AS Ply 4•" or "Ply 6" may be adhered to G-P Gypsum DensDeekk in hot asphalt. ergyGuard Ultra" is an acceptable alternate to "EnergyGuard" in any applicable Classification. GAF Stratavent Eliminator Venting Base Sheet ( Nailable)" may be mechani- cally attached or hot mopped over noncombustible decks and as a recover over eels ttrtg roof s LAS PerL�Insulation may be utilized as a'cover board over "EVER - GUARD" insulation in any of the following systems. Unless otherwise indicated, the roof insulation is mechanically fastened, adhered with hot mopping asphalt or urethane insulation adhesive. Pol rene reference in any of the fn owing Classficatcros include "ENER ]r>sttlation'_ • References to glass fiber insulation include "F.nergyGuard Fiberglass Insu- lation" ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT G2 a sphal t UZglass mat base sheet ( "GAFGLAS #75 Base Sheet" or LAS SAM ") is a suitable alternate for Type 01 asphalt glass firer ply sheet ( "GAFGLAS Ply 4" or " GAFGLAS Fly 6" kin the Class A,13 or. C roof systems indicated below. The roof deck may first be covered with a Type G2 asphalt glass mat ba sheet "GAF Stratavent Eliminator Venting Banc Sheet (Perforated)" or "GAF Stratavent Eliminator Venting Bane Sheet ( Nailable)" . Perforated to be mopped and mailable to be mechanically attached granule side down. As an option Type 02 asphalt glass mat base sheet ( "GAFGLAS 4175 Base Sheet", "GAFGLAS #BO ULT IIIVIA" or "GAF Stratavent Eliminator Venting Base Sheet (Nailablc)" may be substituted for 0) asphalt glass fiber ply sheet ( "GAFGLAS Ply 4" or " GAFGLAS Ply 6" ) as the nailed base ply in the following systems. Bottom ply nr base sheet may be solid mopped, spot mopped or meeitarai- ca lly fastened. 'Unless otherwise indicated, all insulations may be hot mopped or mechani- cally fastened. "GAFGLAS Flashing" or "Ruberoid" may be used for flashing in any of the Class A, or C systems listed below. When "perlite" is referenced, this includes "C;.AFTE,MP PERMALITE ©" or any other. UL Classified perlite insulation. ' Crushed seine or slag are suitable alternates for gravel in any of the Class A, B or C .systems fisted. Structural etmc?nt fiber building units are considered suitable to be included as a deck in the fallowing Class A, B or C cvstems listed over C -15132 or NC. The use of gypsum board under any of the foUowvrg Class A, B or C systeme does not adversely effect the rating. The use of 1/2 in. min gypsum beard is en acceptable alternate for insulation over C -15/32 decks. The use of pnl insulation board between min 3/4 in. perlite board and deck with rosin paper (perlite/rosin paper /polystyrene /perlite) is a suitable alternate fair isocwanurate bnerd in the following Class A, 13 or C systems. BMCiA Bncre�e• Guard RA ", "BMCA Tapered Energy( hard RA" and "BMCA EnergyGuard RA" may be substituted for any Atlas polyisocyanurate iruvla- tion m any of the following Classifications. Trumbull "Perna Mop" may be utilized with any of the following "Asphalt Felt Syysstems wiih Hut Roofing Asphalt ". GAFGLAS #alit: i'remium Base Sheet may be used in any of the following Systems. " GAFGLAS Flex Ply 6" is n suitable alternate to " GAFGLAS Ply 6 ". LOOK FOR THE UL MARK ON PRODUCT ROOF COVERING MATERIALS (TEVT) Roofing Systems (TG)U)— Continued PAGE 04 i1 a ors or SurfacinF Gravel. Deck: C -15/32 Incline: 2 - ' insulation (Optional): One or more layers perlite, wand fiber, glass fiber. isncyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber/isocyanurate composite, phenolic, any thickness. Ply Sheet: Three or. more layers Type G1 • " GAFGLAS Ply 4" or " GAFGLAS Ply 6 ", Cap Sheet One layer Type G3 'GAFGLAS Mineral Surfaced Cap Sheet" or "EnergyCap Mineral Surfaced Cap Sheet". I. Deck: NC • "GAFTRJVIP Permalite Recover Board" may be used in lieu of any peiiire insulation in any of the following NC Classifications. Unless otherwise indicated, any of the Asphalt Felt Systems with Hot Roofing Aspluntt" may be 'surfaced with "Fireshield MB" at 2.5 .. 3.0 gal /sq. Class A, 13 and C Hot roofing asphalt, for use with organic an . glass felts or modified bitumen membranes. "Ruberoid Heat Weld" SBS n:ofing membrane may be used in lieu of "Ruberoid Mop" SBS products in any applicable Classification. Class A Deck: C -15/32 Irtdine: 3 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isacyanurate, urethane, perlite/isocyanurate compcseite, perlite/ urethane composite, wood fiber• /isocyanurate composite, phenolic, any thickness. Ply Sheet Threw or more la T y n ■ p one ): One or more Layers perlite, wood fiber, glass fiber, isocyaourate, urethane, perlite /isoeyanurate composite, perlite/ urethane composite, wood fiber /ism- yanvrate composite, phenolic, 2 in, max. Fly Sheet Two or more layers Type 01 " GAFGLAS Ply 4" or "GAF- GUS Ply 6 ". Cap Sheet One layer Type 03 " GAFGLAS Mineral Surfaced Cap Sheet" or "EnergyCap Mineral Surfaced Cap Sheet ". 4. Dent: NC Incliner 1/2 Insulation: One or two layers "Isotherm R ", 4 in. max, hat mopped. Ply Sheet Any UL Classified gravel surfaced Class A asphalt glass fiber mat system. 5. Deck C- 15/22 Incline: 1 Slip Sheaet•(Optionaq: Red rosin paper, nailed to deck. Base Sheet One layer Type G2 " GAFGLAS #75 Base Sheet" (may be nailed). Ply Sheet One or more layers Type G1 " GAFGLAS Ply 4" or GAFGLAS Ply 6". Cap Sheet: One layer Type G3 " GAFGLAS Mineral Surfaced Cap ' Sheet" or "EnergyCap Mineral Surfaced Cap Sheet ". Deck: NC incline: 3 Base Sheet One layer Type G2 " GAFGLAS #75 Base Sheet". ply Street One nr more layers. Type 01 " GAFGLAS Ply 4" or "GAF - GLAS Piy 6 ". Cap Sheet One layer Type G3 GAFGLAS Mineral Surfaced Cap Sheet" or "BnergyOap Mineral Surfaced Cap Sheet ". 7. Deck: C-15/32 Indite 2 Insulation: One or more layers perlite, glass fiber, isoryanurate. ure thane, perliic /iso cvanurate composite, perlite /urethane composite, phc- nolac. 1.0 in. mm ("offset from plywood joint 6 in.). Base Sheet One or moor layers Type GI.02 ar 03. Membrane: One or more layers "Rubernid larch" (Smooth or Granule). "Ruberoid Torch Plus" (granule). "Ruberoid Mnp" (Smooth or Granule) or "Rubemid Mop Plus" (granule). Cap Sbeee Type 03 " GAFGLAS Mineral Surfaced Cop Sheet" or "Energycrp Mineral iurfacod Cap Sheet ", hot mopped. 8. Deck: C.15 /:t2 Incline: 2 Insulation (Optional): Ono or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isccyanurate composite, perlite/ urethane composite, wood fiber/ isuryanurate compnsile, phenolic, any thickness, Base Sheet: Two or more layers Type G2 or 03, Ply Sheet (Optional): One or more layers Type 01, Membrane: One or more layer:: "Rubermd Torch" (Smooth nr Granule), "Rubenid Torch Plus" (granule), "Ruberoid Mop" (Smooth or Granule) or "Ruberoid Mop Plus" (,granule).