Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ROOFING
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 1 ? c k- Job Address K3 ?Q NC 92-sr Tax Folio i I '' 3 oc- • O �) ;=.•f 6. $e �''6 ( 3 Legal Description n \ /ynp Historically Designated: Yes No Owner/Lessee / Tenant ✓ e I/ v 4 N ( & Owner's Address 1 096 V , v 6 ci 2 sr Phone 7c7 - v/c Contracting Co. -- • 24 G S ` ��� Address Pho tiE 92 s r f \ ?-1A(Ja1 / C/ Phone s9 3- q yam/ State # C C C (D57313 Municipal # Competency # Ins. Co. Architect/Engineer N/A Bonding Company lI N /A Mortgagor N/A Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL( ROOFING PAVING FENCE SIGN — ROO F - 774 . T / — F� / dc6 .�.� - /6U c O Square Ft. ►` � , l ►' ! I 3 300 Estimated Cost (value) 11/ A WORK DESC WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. Signature of owner and/or Condo President Date FEES: PERMIT 9' ?_ 0 0 RADON teary as to O+t6ner and/or Condo President ' D y Commission Expires: • J P •••r ti JAMES F. GOLDBLATT • MY COMMISSION # CC317437 EXPIRES 4 FL` October 22, 1997 BONDED THRU TROY FAIN INSURANCE, INC. APPROVED: Zoning Building ! JfJ 'b Electrical Mechanical Plumbing Engineering Address Address Address Master Permit # c or or Owner- Builder (V otary as to Contractor or Owner - Builder My Commission Expires: Date Date C.C.F. 7 U U NOTARY 5P ® TOTAL DUE //- 0 0 4. 2. Description of improvement: 3. Owner(s) name and address: 6. Lender's name and address: Signature of Owner Print Owners Name STATE OF FLORIDA, lsd C:Q7 C.71 02 YJ l y'. �.TJ �.: y ,J•l5 C i COUNTY O.. CADS •43 6s o Doc , z , z j Q1 tho ca. . •3� c = = = = =� Z 37 ci $zoo 9� • ctl &l, •1 i� o eocrrQD �z n� 9t- /090 NF 9z s r L) ( UQw.. b � AJC o c— Sworn to and subscribed before me this \ day of UN-4 , 199' . .} y Y'P ,,, ,•••��;; JAMES F. OOIDBLATT MY COMMISSION # CC317437 EXPIRES Notary Public _ }',p Print Nota ' ame 2' �� (f fJ t,QPf " J 60NDED THRU TROY FAIN INSURANCE, INC. My Commission Expires: 10 ?All NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. _Vic " STATE OF FLORIDA: COUNTY OF DADE: 1. Legal description of property and street address: '-T2 , ' t-3 B A` 0 - tit o MO S Ct.a fig r� (2-'6 - O DCes ro 1 t 96R320261 1996 JUL 22 10:15 THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. Pc\ ( 33 Interest in property: Name and address of fee simple titleholder: 4. Contractor's name and address: • 2 - /1 - t .19,3/10-‘s C C.l�•- e o NC- 1 2( s r £a cr r cr (--- 33 fbl y 5. Surety:(Payment bond require by owner from contractor, if any) Name and address: Amount of bond $ 7. Persons within the State of Florida designated by Owner upon Whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: V A 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: ✓ 1 /K 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) Prep ed by3 2 66 Add 0 Co,Gc ST /1 123.01-52 123.01.52 2/93 Job Address: ICU t.� q2 ST Adhesives (continued): Additional Notes: Note: Application of adhesives shall be in compliance with the Roofing Component Product Control Approval and the minimum requirements set forth in Subsection 3403.5(e)(4)(cc) of the South Florida Building Code. Ventilation System (check one or more of the following: The following information is required to confirm compliance with Subsection 3401.4(e) of the South Florida Building Code. O Ridge: Type Size t' Soffit: Type tta ize 35b in' qb x VI( Ice Note: If underlayment is comprised of a self - adhered membrane, both soffit and ridge ventilation systems are required, unless a base sheet is applied as an anchor sheet below the self - adhered underlayment. Note: The Tile System Assembly shall be installed in strict compliance with the application instructions enumerated in the Product Control Approval. A permit shall be issued for application of the specified Tile System Assembly only. Any change to the specified Tile System Assembly shall require submission of a revised SECTION II with a copy of SECTION I, noting the permit number issued. Job Address: Ingo qz s Contractor: • Z • L9--1 Process No. Mortar or Adhesive Set Tile Systems Page - 4 Contractor: _--, - 7 i • 000f.i I��NTd ti � R� Q 32.3 °I t) 2►.S� f:1 Deck: Y ('(i Lux° T ype: ` �M�J �/ Thickness: Underlayment: Underlayment r�V ri Fastener: f 4 E- Kis I I Na_ Ns t, 2Y.0 fr 90# 12" DETAIL #1 Job Site Identification: Mortar or Adhesive Set Tile Systems Page - 5 Process No. FILL IN APPLICABLE ROOFING COMPONENTS WIIICII MAKE UP TILE SYSTEM ASSEMBLY. INSERT ANY ADDITIONAL LEADERS INDICATING ADDITIONAL ROOFING COMPONENTS NOT SIIOWN ON THIS PAGE. ( Where Roofing Component not used in Tile Systcm Assembly, fill in with "N /A ". ) Head Lap Dimension: 3 " (minimum 7 unless otherwise specified in the file system assembly Product Control Approval) I n� Mortar /Adhesive: l 1 w �� Tile: f /a r s Tile Fastener: Ridge Venting: — Fastener: d a Metal r utter ( Uavdte�•) / tt N C. Bird Stop: ((rappllcable) Edge Metal 1,1 or Gutter: Existing or Proposed 34 5 _i.e. Soffit Venting: Illy �'t' • auS Job Address: Rid a Height: Eav Height: Roof Mean Height / feet /U feet /3 feet Insert Building Ridge Height, Eave Height and Roof Mean Height. Also insert applicable information pertaining to the building below. ( See ASCE 7 -88 Fact Sheet Attached ) Exposure Category: Classification Category: At Ilurricancc Occanlinc?: Y N Basic Wind Speed at Building Location 110 mph Building Condition based on % of openings: (See Table 9 ofASCE 7 -88) Ground Level Job Address: IMO 1 Ve l 2 �Y Contractor: Contractor: Underlavment (continuedl: Check all of the following which apply to the proposed underlayment for use with the proposed tile system assembly: ASTM #30 asphalt saturated felt with: 0 19" overlap O 6" overlap 5. Related Accessories: r \�� V 4" overlap Manufacturer: ` r ✓ }� ` f�.J (� Edge Metal (refer to Section 3408.2 of the South Florida Building Code): ❑ ASTM #15 asphalt saturated felt with: O 19" overlap O 6" overlap O 4" overlap Manufacturer: Dimensions: Mineral Surfaced Roll Roofing with: Manufacturer: 4J (l C ❑ Other: Type: Manufacturer: Underlavment Fasteners (if applicablel: O 19" overlap O 6" overlap 4" overlap Check one of the following which apply to the proposed underlayment attachment: Minimum 12 ga. electro - galvanized roofing nail with minimum 32 ga. x I / tin cq. • Length: Manufacturer: C, ❑ Other: Type: Length: Manufacturer: le Mortar or Adhcsivc Set Tile Systems Page - 6 Mortar or Adhcsivc Set Tile Systems Page - 3 BUILDING INFORMATION #1 Job Site Identification: Spacing (per the system assembly Product Control Approval): Field: 1 2 " o.c. Laps: " o.c. Type: Gauge or Thickness: 'lb Finish: Note: All edge metal shall be nailed on the flange and nailed or clipped at the face in compliance with the provisions set forth in Dade County Protocol PA 111, marked Appendix 'U' in the South Florida Building Code. Adhesives (check one of the following): ❑ Cold Adhesive: Flashing Cement: Process No. Process No. 55(3" )aViektan--o Type: Manufacturer: Type: Manufacturer: Asial -c� Job Address: Job Address: Tile: Tile Name: Manufacturer: Tile Material: ❑ Clay Concrete ❑ Other: 10% tiE q2 Project Information (continued): If the proposed undcrlayment is self- adhered, have you complied with the venting requirements of Section 2913.3 (b), (c) and (d) of the South Florida Building Code7 yes no Are all related accessories approved for use with this tile system assembly? Are the proposed edge metal attachment fasteners in compliance with the requirements of the South Florida Building Code (minimum 12 ga. annular ri _ : ;ank, corrossion reisistant nails)? no no 4. The Tile System Assembly: The following information is required to confirm compliance with Subsections 3403.5(a) and (c) and Section 3404 of the South Florida Building Code. Product Control Approval Number: Mortar or Adhesive: r SIttue ( lc 0322-02 Check one of the following which apply to the proposed tile securement for use with the proposed tile system assembly: Mortar or Adhesive Set Tile Systems Page - 2 1090 9zs7 3 i2 Contractor: 3l— Mortar or Adhesive Set Tile Systems Page - 7 ❑ Mortar: Manufacturer: Mixing Ratio: n ' I L /'� /< Adhesive: Type: f ci /� ,1 Tt -/60 Manufacturer: Pacouc fs Tile Fasteners (for first three courses if roof pitch exceeds 5 ":12" and is less than or equal to 7 ":12 "): Check one of the following which apply to the proposed tile fasteners (for the first three courses) for use with the proposed tile system assembly: ❑ Minimum 12 ga. galvanized roofing nail: ❑ Other: Type: Length: N/A Note: All tiles shall be installed in compliance with the provisions set forth in the tile system assembly manufacturer's Product Control Approval and the minimum requirements set forth in Subsections 3403.5(c) and 3404.2 of the South Florida Building Code. Tile fasteners in the first three courses (if applicible) shall be of sufficient length to penetrate the sheathing a minimum of 1" or through the sheathing thickness a minimum of / ", whichever is less. Underlayment: The following information is required to confirm compliance with Section 3403.5(b) of the South Florida Building Code. Sketch Roof Plan, indicating all dimensions, slopes and any roof top equipment. Also insert variable labeled "a" which represents perimeter and comer dimensions per Chapter 23 of the South Florida Building Code. (See ASCE 7 -88 Fact Sheet Attached ) Length: A BUILDING INFORMATION #2: Roof Plan with Perimeter and Corner Dimensions Job Site Identification: Process No. rocess No. Job Address: V s( The undersigned certifies that the Mortar or Adhesive Set Tile System Assembly is in compliance with the plans, specifications, and details submitted by the architect. STATE OF FLORIDA - COUNTY OF DADS Before me this day ersonall appeared u .0V Y P. Y PPce who, being first duly sworn,; deposes and says that 'allinfor tion submitted herein is true and correct. Sworn to and subscribed before me this /g th day of 19 gy My commission expires: APPENDIX 'E' METRO -DADE UNIFORM BUILDING PERMIT SECTION II MORTAR OR ADHESIVE SET TILE SYSTEMS 1. General 2. Documentation ignature weer SP RY P1 OFFICIAL NOTARY SEAL SANDRA IA d1ONTIEL • ORIMISSION oER • CC4'1261 ct• fie. Y CON Notary Public State of Florida The information provided in this Section is required to confirm Product Control Approval of the proposed tile system assembly; confirm compliance with the wind load requirements of Chapter 23 of the South Florida Building Code (SFBC); and confirm compliance with Sections 3403.5 and 3404 of the South Florida Building Code. The following documents are required for submission with the Uniform Building Permit application: ► Two (2) copies of the proposed tile system assembly's and • associated roofing component's Product Control Approval(s). ► One (1) copy of the tile system assembly and/or roofing component(s) manufacturer's published application instructions and literature. ► All documents attached herein, filled out and completed in full. 3. Project Information Check one of the following: 12ao1 -158 New Construction Re -Roof Noie: Mortar or adhesive set tile systems are not acceptable as recover applications. I4 Mortar or Adhcsivc Set Tile Systems Page - 8 Mortar or Adhcsivc Set Tile Systems Page - 1 r ' r ocess No. Job Address: JOCI 0 NC 6 1 2 ST Contractor: Roof Pitch (fill in): " : 12" no Is the deck solid sh ? (circle yes' or 'no') no Deck Type (check one of the following): ❑ Nominal ''A" Plywood (for re-roof only) t r,, Nominal V Plywood Wood Plank ❑ Other (fill in) Note: Mortar or adhesive set tile systems shall not be installed at a pitch greater than 7'W:12 ". Mortar or adhesive set tile applied at a pitch greater than 5 ":12" and less than or equal to 7 ":12" shall have the first three courses of tile nailed with not less than one nail per tile. As an alternate, the first three courses of tile may be applied in mortar over a single layer of minimum 12 ga. wire mesh with square openings of not less than '/ which is mechanically attached to the sheathing with not less than one nail per 2 ft Circle 'yes' or 'no' for each of the following: Have you attached two copies of the tile system manufacturer's Product Control A 'royal for the proposed tile system? no Have you attached a copy of the tile system assembly and/or roofing component(s) manufacturer's published, application instructions and o :.-,. iterature no Is the proposed underlayment approved for use with this tile system assembly? • M D ® Approved: 'JUL 1 8 1995 pROnUCT CONTROL. NOTICE OF ACCEPTANCE, Monier, Inc. 1900 Northwest 21st Avcnue Fort Laudcrdalc, Florida 33111 Acceptance No.: 95- 0322.02 " Rcviscs No. 95- 0301.02 Expires: ' JUL 1 8 1998 BUILDING CODE COMMITTEE, 1 METROPOLITAN DADE COUNTY, FLORIDA METnO•DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE DEPARTMENT SUITE 1603 METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130.1503 (305) 375.2001 FAX (305) 376.2000 Your application for Product Approval of: Monier Nail-On, Mortar Set or Adhesive Set "Flat Shake &Slate" Roofing Tile undcr Chapter 8 of thc Mctropolitari Dadc County Codc governing thc usc of Alternate Materials and Typcs of Construction, and completely described in the plans, specifications and calculations as submitted by: Redlaml Technologies, The Center jor Applied Engineering, Inc, and Professional Service Industries has been recommended for acceptance by tlic Building Codc Compliance Department to be uscd in Dadc County, Florida under the specific_conditions set_forth on pages 2 through 17 and the standard conditions set forth on page - -- The approval shall not bc valid after the expiration date stated below. The Building Codc Compliance Office reserves thc right to secure this product or material at any time for a jobsitc or manufacturer's plant for quality control testing. If this product or matcrial fails to perform in the approved manner, thc Building Code Compliance Officc may rcvokc, modify or suspcnd thc usc of such product or matcrial immediately. Thc applicant shall rc- evaluate this product or material should any amendments to the South Florida Building Codc be enacted affecting this product or matcrial. Thc Building Code Compliancc Office rrserves thc right to revoke this approval, if it is determined by thc Building Codc Compliancc Officc that this product or matcrial fai s for yp-ct the requirements of .- thc South Florida Building Codc. The expense of such testing will bc incurr • • , th /la 1ufactu r. Caul Rodriguez Product Control Supervisor TUTS IS THE COVERSHfl T. SEE AD`�NO AL PAGES FOR SPECIFIC Arm C;ENERAL This application for Product Approval has bccv Codc Committee to bc uscd in Dade Cou uilding Codc undcr Compliancc Department and approved by thc Building the conditions set forth above. Charles Dangcr, P.E. Director a. Building Codc Compliancc Dcpt. Metropolitan Dadc County ait-J Applicant: Product Control No.: 95- 0322.02 Monier Roof Tile 1900 Northwest 21st Avenue . 'JUL 8 1995 Fort Lauderdale, FL 33111 Approval Date: Category: Prepared Roofing sub- Category: Flat Profile Tile Typ Nail- on/Mortar Set/Adhesive Set Concrete System Description Monier Roof Tile is a member of the Redland Group, a world widc producer of primary building products and roof tile. . manufacfiireri *concrete roof tile for nail -on, mortar set or adhesive set applications in plants throughout the United States ranging from Washington State to Florida. All tile is manufactured from extruded concrete consisting of Portland Cement, plasticizer, iron and metallic oxides, and blended aggregates. This Product Control Approval relates to Monier's "Flat Shake and s Refer to appmpriate Product Control Approvals for other tilt profiles. Monier sells tile systems through local distribution and directly to consumcrs. All profiles have matching trim pieces used for rake hip, ridge hip, and valley terminations. Tile system accessories such as undcrlayment, ventilation systems and flashing Product Control systm aso available. These accessories are manufactured for all profiles and form a part of Monices "Flat Shake and Slate" roof tile has been tested in compliance with the South Florida Building Code requirements for concrete, nail -on, mortar set and adhesive set tilt applications. The minimum roof slope for Monier's "Flat Shake and Slate" nail -on, mortar set or adhesive set tiles shall be 2 ":12 ". See the "Profile Drawing" section in this Approval for the "Flat Shake and Slate" tile profile. Monier's "Flat Shake and Slate ".tile profile has been tested for both wind characteristics and static uplift performance, therefore, any consideration for installation shall be done as a 'Momcnt Based System'. Data for attachment calculations is noted in Tables 1 through 4 of this Approval. . • PRODUCT, CONTROL NOTICE OF ACCEPTANCE . ROOFING SYSTEM APPROVAL Contact: Reese H. Moody • Technical Service Accessories Manager . 1900 NW. 21st Avenue Ft. Lauderdale, FL 33311 (800) 432 -2715 2 Expiration Date: 'Jul 1 8 1998 Pr_ Monier Flat Shake and Slate Tile Trine Pieces r • .0 • TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Tcst Product j)imensions $pcciftcntiott Description 1 16%" PA 112 Flat, interlocking, high pressure w — 13" extruded concrete shake and slate roof '1 thick tile equipped with two nail holes. For direct deck or battened nail -on, mortar or adhesive set applications. 1... varies w - varies varying thickness PA 112 • 3 n...1 D r4rinttt 7 Product Control Nc.: 9 O Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. • Product #30 Felt #43 Coated Base Sheet Mincral Surface Cap Shcct Lcnzingtex -ZB 140 59" x 164' roll Underlayment 22 Ibs/roll Rainproof 11 lcc and Watcr Shicld Mopping Asphalt Flashing Cemcnt TRADE NAMES OF PRODUCTS MANUFACTURED OTHERS Dimension= N/A WA 30" x 75' roll 36" x 75' roll or 60" x 75' roll 36" x 75' roll N/A N/A N/A Tcst 5pecificationl ASTM D 226 type II ASTM D 2626 ASTM D 249 PA 104 PA 104 PA 103 ASTM D 312 type Ill or 1V ASTM D 4586 4 Raul Rodriguez Single ply, nail -on underiaymcnt. Self - adhering undcriaymcnt for usc as a top ply in a two ply undcriaymcnt system with Approved #30 or #43 as the base layer. Asphalt for bonding a mineral surface cap to a mech. attached base sheet in a double ply underlaymcnt system. Cut back, asphalt• • • based, asbestos frce, fiber reinforced, trowel grade ccmcnt for repair and flashing applications. Product Control No.: , 95 03 22_02 Product Description Saturated organic felt to be used as a nailcd anchor sheet. Saturated and coated organic base sheet for single or doublc ply underiaymcnt. Mincral surfaced asphalt roll roofing for usc as a top ply in a doublc ply :. undcriaymcnt system. Single ply, nail -on undcriayment with 2" self - adhering top edge. Manufactnrcr generic generic gcncric Lcnzing Performance, inc. with current PCA Protcct -O -Wrap, Inc. with current PCA W.R. Grace Co. with current PCA generic generic Product • Asphalt Primer Roofing Nails Tin Caps Wood Battens Tile Nails Tile Screws Roof Tile Mortar ("TileTite ") Roof Tilc Mortar ( "Quikrctc® Roof Tile Mortar 111140 ") . nimension N/A min. 12 ga. with ' /." head min. 32 ga. min. 1' 4" o.d. max. 2" o.d. vertical min. 1" x 4" horizontal min. I" x 4" for use with vertical battens or min. I" x 2" for use alone min. 8d x 2%" or min. 10d x 3" #8 x 2h" long 0.335" head dia. 0. 131" shank dia. 0.175" screw thread diameter • N/A N/A Test Specifications ASTM D 41 PA 114 Appendix E PA 114 Appcndix E PA 114 Appendix E PA 114 Appendix E PA 123 PA 123 5 Product Description Manufacturer Cut back, asphalt generic based coating used to facilitate bonding of dissimilar materials. Annular ring shank, hot dipped, elcctro or mechanically galv. roofing nails for use in underlaymcnt attachmcnt. Corrosion resistant circular disc for use in undcrlaymcnt attachment Wood Preservers Salt pressure treated Institute LP - 2 or decay resistant lumber battens Corrosion resistant, screw or smooth shank nails. Corrosion resistant, coated, square drivc, galvanized, coarsc thread wood screws Prcparcd mortar mix designed for mortar sct roof tilc applications. Product Control Nc.: Preparcd mortar mix designed for mortar set roof tilc applications. os -c1?2 Q2 gcncric generic gcncric gcncric gcncric Bcrmuda Roof Company, Inc. with currcnt PCA Quikrctc Constructio Products with currcnt PCA .3 I product nimensiona Specifications Roof The Mortar ( "BONSAI.® Roof Tile Mortar Mix") Hurricane Clip & • Fasteners N/A • PA I23 Roof Tile Adhesive N/A PA 110 Adhesive designed Polyfoam Products, (Polypro® AH160) for use in roof tile Inc. applications. with current PCA PA 114 min. %" width Appendix E min. 0.060" thick Clin Fasteners min. 8d x 1'i." 6 Product Control No.: QS- 0322.02 Product Description Prepared mortar mix designed for mortar set roof tilt applications. Corrosion resistant bronze, aluminum, stainlcss stecl, galvanized steel or plastic attachment clips for supplemental tile attachment. Clips - arc installed with corrosion resistant roofing nails compatible with the clip. A hurricane clip is rcquircd on all nail -on cavc tilts. Valley Flashing . min. 26 ga. ASTM A 525 Galvanized steel gcncric min. 16" width vallcy flashing Drip Edge min. 26 ga. PA 111 Galvanizcd stccl drip generic min. 2" face flange edge min. 2" deck flange Manufacturer W.R. Bonsai Co. with current PCA generic Test Agency Rcdland Technologies Rcdland Technologies The Center for Applied Engineering, Inc. The Ccnter for Applied Enginccring, Inc. 'The Ccnter for Applied — — Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Thc Ccnter for Applied . Engineering, Inc. The Ccntcr for Applied Engineering, Inc. r Thc Center for Applied Engineering, inc. Test Identifier 7161 -03 Appendix III 7161 -03 Appendix III 94 -084 94 -060A TEST REPORTS --- 25;1094-2 • "" -. 25- 7094 -8 25- 7094 -5 25- 7183 -6 25- 7183 -5 25- 7214 -1 7 Test Name/Report Static Uplift Testing PA 102 Static Uplift Tcsting PA 102(A) Static Uplift Testing PA 101 (Mortar Sct) Static Uplift Testing PA 101 (Adhcsivc Set) Static Uplift Tcsting PA 102 (4" Hcadlap, Nails, Direct Deck, New Construction) Static Uplift Tcsting PA 102 (4" Hcadlap, Nails, Battcns) Rnul Rodri!ucz Static Uplift Testing PA 102 (4" Hcadlap, Nails. Dircct Deck, Rccovcr /Reroof) Static Uplift Testing PA 102 (2 Quik-Drivc Screws, Direct Dcck) Static Uplift Tcsting PA 102 (2 Quik -Drivc Scrcws, Battens) Static Uplift Testing PA 102 (1 Quik -Drivc Scrcw, Dircct Deck) Product Contro: No.: ot- r1:22.02 Data Dec. 1991 Dec. 1991 May 1994 March, 1994 Oct. 1994 Oct. 1994 Oct. 1994 Fcb. 1995 Fcb. 1995 March, 1995 Test Ar+ency, The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Professional Service Industries, Inc. Test Identifier 25- 7214 -5 7161 -03 Appendix II Letter Dated Aug. 1, 1994 P0631 -01 PO402 Project No. 307025 Test #MDC -77 224 -47099 8 D....1 D ,..i..:..i.e.� Test NamefRcrzort Static Uplift Testing PA 102 (1 Quik -Drive Screw, Battens) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Sct) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Driven Rain PA 100 Physical Properties PA 112 Product Control No.: 9c-0722 02 hate March, 1995 Dcc. 1991 Aug. 1994 July 1994 • Sept. 1993 Oct. 1994 Sept. 1994 Deck Type: Wood, Non - insulated Deck Description: New Construction "/ or greater plywood or wood plank. SYSTEM A: Counter -Batten Application Slopc Rangc: 2 ":12 ".to 7 ":12" • Notc: Countcr - Batten, as notcd below, arc rcquircd for slopc range 2 ":12" to less than 4 ":12" and arc optional for slopes of 4 ":12" to 7 ":12 ". For slopes exceeding 7":12", refer to Systcm C. • Undcrlaynicnt: Install underlayrnent system in compliance with Dade County Application Standard PA 118. Vertical Battens: Install vertical battens in compliance with Dade County Application Standard PA 118 • Horizontal Battcns: Install horizontal battens in compliance • with Dade County Application Standard PA 118. Roofing Tilc: Install tile in compliance with Dade County Application Standard PA 118. (See "Data for Attachment Calculations" included in this Approval.) Comments:. 1. For re -roof applications, 13 / 32 " plywood is an acceptable substrate. SYSTEMS 17 neel RnriritueAT Product Con O: Nc.: °C -' . Roofing Tile: Deck Type: Dcck Description: SYSTEM B: Slopc Range: Undcrlaymcnt: Com • r , Wood, Non - insulated SYSTEMS (CONTINUED) New constriction t ' / or greater plywood or wood plank. 1 0 Product Control No.: 0c-07,22_02 Direct Deck Application 4 ":12" to 7 ":12" Note: : System B is only acceptable in this slope range. For slopes less than 4 " :12 ", refer to System A. For slopes in cxccss of 7 ":12 ", refer to System C. Install underlayment system in compliance with Dade County Application Standard PA 118. Install tile in compliance with Dade County Application Standard PA 118. (See "Data for Attachment Calculations" included in this Approval.) 1. For re -roof applications, "/„" plywood is an acceptable substrate. Deck Typc: Deck Description: SYSTEM C: Slopc Rangc: Undcrlaymcnt: • SYSTEMS (CONTINUED) Wood, Non - insulated New construction "/ or greater plywood or wood plank. Horizontal Batten Application Product Control No.: 95 077 - 4 ":I2" or greater Note: Horizontal battens, as noted below, arc required for slopes in cxccss of 7 ":12" and are optional for slopes of 4 ":12" to 7 ":12 ". For slopes less than 4 ":12 ", refer to Systcm A. Install underlayment system in compliance with Dadc County Application Standard PA 119. Horizontal Battens: Install horizontal battens in compliance with Dade County Application Standard PA 119. Roofing Tile: Install tile in compliance with Dade County Application Standard PA 119. (See "Data for Attachment Calculations" included in this Approval.) Comments: 1. For re -roof applications, "/ plywood is an acceptable substrate. 11 SYSTEMS (CONTINUED) Deck Type: Wood, Non - insulated Deck Description: New construction 1 1/2 3 " or greater plywood or wood plank. SYSTEM D: Mortar or Adhesive Set Application Slope Range: 2 ":12" to 7 ":12" Note: System D is only acceptable in this slope range. For slopes in excess of 7 ":12 ", refer to System C. Underlayment: Install underlayment system in compliance with Dade County Application Standard PA 120. (See System Limitation 115.) * " Roofing Tile: - -•. - -. - Install ' tile - .comp'lance with Dade County Application Standard PA 120. (See "Data for Attachment Calculations" included in this Approval.) Comments: 1. For re -roof applications, u /,." plywood is an acceptable substrate. • 12 Product Control No os -0322 02 •• SYSTEM LIMITATIONS Product Control No.: 9c-0122.02 1. The standard minimum•roof pitch for Monier's "Flat Shake & Slate ", low profile tile shall comply with Dade County Application Standards PA 118, PA 119 or PA 120, depending on the method of installation. 2. For nail -on applications, fasteners for mechanical attachment of tiles shall have a head diameter larger than that of the preformed holes in the tile. • 3. System installation shall be in compliance with the system specifications outlined in this Product Control Approval. The method of attachment utilized shall provide sufficient attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with Dade County Protocol PA 115 or PA 127. The Monier "Flat Shake & Slate" tile profile has been tested for both wind characteristics and static uplift performance, therefore, attachment calculations for installation in compliance with PA 115 or PA I27 shall be done as a 'Momcnt Based System'. 4. For mortar or adhesive set tile applications, a field static uplift test by a Dade County accredited testing agency, in compliance with Dade County Protocol PA 106, shall be performed. 5. For mortar set tile applications, 30/90 hot mopped underlayment applications may be installed perpendicular to the roof pitch unless stated otherwise by the underlayment material manufacturer's published literature. 6 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo for identification in the field. 7. Applications for roofing permits shall include a completed Section II of the Uniform Building Permit, a copy of Monier's current specifications and details, a copy of this Product Control Approval and a copy of the Product Control Approval of any Roofing Component used in the proposed tile application. Reference shall be made to appropriate data for the required fire rating. 8. The applicant shall retain the services of a Dade County certified testing laboratory to maintain quality control in compliance with the South Florida Building Codc and related protocols. Samples taken shall be in compliance with Dade County Protocol PA 112, Appendix 'A'. 9. Any amendments to these provisions shall be in compliance with Sections 203 and 204 of the South Florida Building Code. 13 - DATA FOR ATTACHMENT CALCULATIONS Table 2: Restoring Moments due to Gravity - M. (ft -lbf) Tile Profile Monier Flat Shake & Slate 3 ":12" Battens 6.57 Direct Deck 7.52 • 4 ":12 Battens Direct Deck 6.47 7.43 5 ":12" Battens 6.33 Direct Deck 7.27 6 ":12" Battens 6.17 Direct Deck 7.09 7":12" or greater Battens 6.00 Direct Deck N/A Table 3: Attachment Resistance Expressed as a Moment - M, (ft - Ibf) for Nail -On Systems' Tile Profile Monier Flat Shake & Slate Tile Application Battens Direct Deck Approved Nails 1 nail 4.90 9.80 2 nails 7.40 18.80 Approved Screws 1 screw 2 screw s 18.20 28.60 30.80 51.70 Approved Field Clip With: 1 nail 24.20 24.30 2 nails 34.80 35.50 Approved Eave Clip With: 1 nail 22.10 19.00 2 nails 32.20 31.90 Data noted in Table 3 is for installation with a 3' tile headlap. Approved screws are as noted in the 'Trade Names of Products Manufactured. By Others' and 'Profile Drawings' sections of this Approval. Clips on eave tile are not required for this attachment configuration unless the Required Moment of Resistance exceeds the values noted above. 14 RaulRodri!ucz Product Control No.: 9s-011'.0/ Table 1:- Aerodynamic Multipliers - l (ft') Tile Profile X(n') • Batten Application X( ) Direct Deck Application Monier Flat Shake & Slate Tile 0.27 0.29 - DATA FOR ATTACHMENT CALCULATIONS Table 2: Restoring Moments due to Gravity - M. (ft -lbf) Tile Profile Monier Flat Shake & Slate 3 ":12" Battens 6.57 Direct Deck 7.52 • 4 ":12 Battens Direct Deck 6.47 7.43 5 ":12" Battens 6.33 Direct Deck 7.27 6 ":12" Battens 6.17 Direct Deck 7.09 7":12" or greater Battens 6.00 Direct Deck N/A Table 3: Attachment Resistance Expressed as a Moment - M, (ft - Ibf) for Nail -On Systems' Tile Profile Monier Flat Shake & Slate Tile Application Battens Direct Deck Approved Nails 1 nail 4.90 9.80 2 nails 7.40 18.80 Approved Screws 1 screw 2 screw s 18.20 28.60 30.80 51.70 Approved Field Clip With: 1 nail 24.20 24.30 2 nails 34.80 35.50 Approved Eave Clip With: 1 nail 22.10 19.00 2 nails 32.20 31.90 Data noted in Table 3 is for installation with a 3' tile headlap. Approved screws are as noted in the 'Trade Names of Products Manufactured. By Others' and 'Profile Drawings' sections of this Approval. Clips on eave tile are not required for this attachment configuration unless the Required Moment of Resistance exceeds the values noted above. 14 RaulRodri!ucz Product Control No.: 9s-011'.0/ • • DATA FOR ATTACHMENT CALCULATIONS (CONTINUED) Table 3-A: Attachment Resistance Expressed as a Moment - M1 (ft -Ibf) For Nail -On Systems Tile Profile Monier Fiat Shake & Slate Tile . Application Direct Deck New Construction (min. "/si plywood) Direct Deck Recover/Reroof (min. " /u plywood) Battens New Construction • Two (2) 10d x 3" long nails' 65.50 50.30 48.30 Tile installation with corrosion resistant, the head of the tile. unless the Required a 4' headlap using two (2) Approved 10d x 3' long polymer coated, ring shank nails installed in manufactured holes located 2%' from Clips on eave tile are not required for this attachment configuration Moment of Resistance exceeds the values noted above. 15 Product Control No.: 9s- 0322.02 Table 4: Attachment Resistance Expressed as a Moment - Mr (ft -Ibf) for Mortar or Adhesive Set Systems Tile Profile Monier Flat Shake & Slate Tile Application Mortar Set Adhesive Set Attachment Resistance 39.00 118.90 PROFILE DRAWINGS SHAKE & SLATE TILE • anti 0 yoOOndmica TOP MS Of NOM noted Owoowao at Monks Fmk* • Ws O.s a. woo moo. SkboorsWool b aglow ot soots an kw Oscoroao orlocL rt�rrrar SwaiaWPM Fa too cordon and nand Kix_ 1M vInelnl MOMS mail ONOISSIOISIIKV°VW _ bosom Hood woo an ordeattooldnaa nor lugs ada+000rtair cionronoNonl manor ammo' Om • SHAKE & SLATE TILES ACCESSORIES NI/ sTAfile Fa woos o al � Ttlt bo rdrad awo pools laws or Como Ior, 10tH a d MONIER FLAT SHAKE & SLATE TILE 16 Product Control No.: 9s- 0322.42 or • . . PROFILE DRAWINGS • • • (CONTINUED) • Product Control No.: 95-01" "*— \******* 0 3 0 10 . . . 2.4111" • 23 OILS. 0.131' APPROVED SCREW FOR SCREW DATA IN TABLE 3 • • 1 O • • .; 1. Extensions of Acceptance may be considered after a new application has been filed and the supporting data, test reports no older than ten (10) years, have been re- evaluated. All reports of re- testing shall bear the seal, signature and date of an engineer registered in the State of Florida. 2. Any revision or change in the materials, use, or manufacture of the product or process shall automatically be cause for termination, unless prior approval is granted for revisions or change. 3. A unsatisfactory performance of this product or process or a change in Codc provisions shall be grounds for re- evaluation._. -'— 4. This acceptance shall not be used as an endorsement of any product for sales or advertising purposes. 5. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. • 6. Product approval drawings, where required for permit applications, shall be provided to the applicant by the manufacturer or his distributors unless otherwise noted in the Notice of Acceptance. The prints need not be re- sealed by an engineer. • 7. Failure to comply with the Standard Conditions shall be cause for termination of the Approval. This approval supersedes all previous approvals. • J1OTTCF OF AC.C'F.PTAN STANDARD CONDTTTONS 18 Raul Rodriguez Product Control Supervisor Polyfoant Products, Inc. 2400 Spring - Stuebncr Road Spring, Texas 77383 METROPOLITAN DADE COUNTY, FLORIDA METRO.OADE FLAGLER BUILDING OUILDING CODE COMPLIANCE DEPAf1TMENT SUITE 1003 METRO.0A0E FLAMER BUILDING 140 WEST RACIER STREET MIAMI, FLORIDA 33130 -1563 (305) 375.2901 I'RODIJCT CONTROL NOTICE OF ACCEPTANCE FAX (305) 375.2909 Your application for Product Approval of Polyfoam Products "Polvnro AH -160" Roof Tile Adhesive under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by The Center for Applied Engineering, Inc. and Miles Laboratories Polymers Division has been recommended for acceptance by the Building Code Compliance Department to bc used in Dade County, Florida under the specific and standard conditions set forth herein. The approval shall be valid for a period of three years. The Building Code Compliance Department reserves the right to secure a product or material at any time for a jobsite or manufacturer plant for quality control testing. If. product or material fail to perform in the approved manner, thc Code Compliance Department may revoke, modify or suspend the use of such product or material immediately. The Building Code Compliance Department reserves the right to require testing of this product or material should any amendments to thc South Florida Building Codc bc enacted affecting this product or material. The expense of such testing will bc incurred by the Manufacturer. PRODUCT NO.: / ACCEPTANC>r` 95-0314.10 �/ EXPIRES: APA 2 7 1998 APPROVED: APR 2 7 1995 ul Rodrigu Control Division Supervisor - PLEASE NOTE - TIIIS IS TIIE COVERSIIEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS. BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Departnic.it and approved by the Building Code Committee to bc used in Dade County, Florida under the conditions set forth above. 'P.E.. D irector Building Code Compliance Department Metropolitan Dade County Applicant: Polyfoam Products, Inc. 2400 Spring - Stuebner Road Spring, Texas 77383-1132 Category: Roofing Component Sub - Category; Fastening/Adhesive Type; Roof Tile Adhesive Suh -Tvpe: Two Component Polyurethane PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING COMPONENT APPROVAL Product Control No.: 95- 0314.10 Approval Date: APR ? 7 1995 Expiration Date: APR 2 7 1998 System Description Polyfoam Products, Inc., produces two- component expanding polyurethane adhesive for the attachment of clay and concrete roof tile. Polypro® AHI60 is specially designed for application of concrete and clay roof tile over a variety of roof deck substrates and underfayment materials. Polypro® adhesive is applied with proprietary Foampro® RTF1000 dispensing equipment. Approval of this product is specific to the two component mix and Foampro® RTF1000 dispensing equipment. Alternative methods of dispensing will require a revision to this approval. Polypro® adhesive shall be applied only by 'Qualified Applicators', licensed by Polyfoam Products, Inc. Certificates and identification cards are issued to applicators upon successful completion of a application training program. Approval of this adhesive system is continent upon application by a 'Qualified Applicator. Contact: Pat Murray P.O. Box 1132 Spring, Texas 77383-1132 (713)350 -8838 Fax: (713)233 -(450 Raul Rodriguez TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Test Product Product Dimensions Specifications Description Polvpro® AHIGO N/A PA 101 Two component polyurethane Foampro® RTF1000 N/A See Detail Attached Dispensing Equipment Raul „ Airiguez Product Underlavment Root - Tile TRADE NAMES OF PRODUCTS MANUFACTURED BY OTIIERS Test Criteria PA 120 PA 101 Product Description All Dade County Component Approved products as detailed in Dade County Application Standard PA 120 All Approved roof tile systems having tested in compliance with Dade County Protocol PA 101, as detailed in the systems section of this Component Approval 3 11110 16 Rlsul Rodriguez Manufactu All Dade County Approved Products All Dade County Approved Products Dimensional Stability Closed Cell Content ASTM D 2126 ASTM D 2856 TEST REPORTS Test Accncv Test Identifier Test Name/Report Date Center for Applied #94 -060 Mctro Dade Protocol 04/08/94 Engineering PA 101 Miles Laboratories N13- 589 -631 ASTM D 1623 02/01/94 Polymers Division TYPICAL PHYSICAL PROPERTIES Property Test Results Density ASTM D 1622 1.6 lbs. /ft.' Compressive ASTM D 1621 18 PSI Parallel to rise Strength 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs. /Ft Moisture Vapor ASTM E 96 3.1 Perm / Inch Transmission 4 +0.07% Volume Change a -40° F., 2 weeks +6.0% Volume Change © 153 °F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. R: 1 Rodriguez Deck Type: Deck Description: SYSTEM A: Slope Range: Undcrlayment: Roofing Tile: S YSTEMS Wood, Non - insulated, New Construction /Reroof New construction " /,:" or greater plywood or wood plank. Re -roof " /,:" or greater plywood Adhesive Set Application 2 ":12" to 7 ":12" Install choice of Approved underlayment system, noted on Page 1 of Dade County Protocol PA 120, in compliance with Section 3.02 of PA 120. Install Approved tile system in compliance with PA 120. Adhesive shall be applied in compliance with the Component Application section and the corresponding Placement Details of this Roofing Component Product Control Approval. The adhesive attachment shall provide sufficient attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with PA 115 or PA 127. The adhesive attachment data is noted in the tile Roof System Assembly Product Control Approval. Comments: 1. For re -roof applications, minimum " /,:" plywood is an acceptable substrate. 2. All 'System Limitations' noted in the tile Roof System Assembly Product Control Approval shall apply. 5 Ra R odriguez `. V1111U 11 • U.. ?. 1 -U�I:; I ) S YSTEMS (CONTINUED) Deck Type: Concrete, New Construction/Reroof Deck Description: New construction SYSTEM 13: Adhesive Set Application Slope Range: 2 ":1 to 7 " :l2" Undcriayment / Install Approved underlayment system of one of the following: Waterproofing: Roofing Tile: Underlayment System 41 (30/90 Hot Mop) noted on Page 1 of Dade County Protocol PA 120, installed in compliance with Section 3.02(A) of PA 120 or Any Approved urethane or asphalt based concrete waterproofing component installed in compliance with the waterproofing component manufacturer's Roofing Component Product Control Approval. Strips of reinforcing fabric shall be installed at all concrete deck joints. Install Approved tile system in compliance with PA 120. Adhesive shall be applied in compliance with the Component Application scction and the corresponding Placement Details of this Roofing Component Product Control Approval. The adhesive attachment shall provide sufficient attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with PA 1 1 S or PA 127. The adhesive attachment data is noted in the tile Roof System Assembly Product Control Approval. Comments: 1. For re -roof applications, minimum " /,_" plywood is an acceptable substrate. 2. All 'System Limitations' noted in the tile Roof System Assembly Product Control Approval or waterproofing component Roofing Component Product Control Approval shall apply, as applicable. Raul odriguez uuuct Lontrot Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Two -Piece Barrel #I 'S' Shaped #2 Double Roll #3 Large Flat #4 Small Flat #5 COMPONENT APPLICATION 7 Raul Rodriguez rcuuuLt Lontrot 1 Polypro® AH I60 tile adhesive shall only be applied over an underlayment installed in compliance with application instructions detailed in its Component Approval.. Underlayment shall be any underlavments or underlayment systems listed as Approved in Dade County Protocol PA 120. 2. Adhesive application shall be in accordance with the instructions provided in this Component Approval, the manufacturer may provide additional instructions subsequent to this approval date which shall prevail. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. 3. Calibration of the Foampro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0 -1.15 (A) : 1.0 (B). The dispense timer shall be set to deliver 0.08 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved without revision of this Component Approval. 4. Adhesive shall be dispensed in a 17 in' to 23 in pad at time of application. The cured pad shall be approximately 5" x 12 ". Foam placement shall be in accordance .with the 'Placement Details' provided in this Component Approval. Each generic tile profile requires a specific placement, as noted in Table 1, below. A tile manufacturer may test a tile system in compliance with PA 101 and add an additional detail without incurring an additional revision cost. 5. Adhere tile directly in freshly applied adhesive. Tile must be set within 2 to 3 minutes after foam has been dispensed. 6. Adhesive shall be placed to create contact with minimum 2 tiles, as outlined in the 'Placement Detail' for each tile profile. SYSTE,`t LIMITATIONS 1. Tile must be applied within 2 to 3 minutes of the application of Polypro® AHI60 adhesive. 2 . P olyp ro® AH 160 adhesive shall be installed only by 'Qualified Applicators' approved and licensed by Polyfoam Products, Inc. 3. For adhesive set tile applications, a field static uplift test by a Dade County accredited testing agency, in compliance with Dade County Protocol PA 106, shall be required not less than 72 hours after application to confirm tile adhesion. The results of this testing shall be reported to the Building Official and the installer stating that the application has passed or failed PA 106 testing. If the application fails PA 106 testing, the report shall state which portion of the test was failed; Category I (examination for loose tile) or Category 2 (uplift testing of tile). Subsequent to testing, the installer may repair not more than 5% of field area tiles and 10% of perimeter area (i.e. ridge /rake) tile with approved tile adhesive. The installer shall place an identifiable marking on each repaired tile for future reference. Any PA 106 re -test shall not include any marked tile. 4. Refer to application drawings published by the National Tile Manufacturers Association for penetrations and terminations, as well as the 'Placement Details" included with this Component Approval. 5. Refer to tile Roof System Assembly Product Control Approval for system Approvals with this Component. 6. Refer to the Prepared Roof System Assembly for fire rating. 7. Polypro® AH 160 shall not be exposed permanently to sunlight. S. Polypro® A1-1160 shall be applied with Foampro RTF1000 dispensing equipment only. 9. Any amendments to these provisions shall be in compliance with Sections 203 and 204 of the South Florida Building Code. 8 Raub odrigucz PLACEMENT DETAILS PAH MORTAR BEO ._. FOR COVER MC NFCPHLLC COYER uETAI EJ YZ ORIP mortar env.: CloeurS rational ;oir.; -up mortar FASCIA OOAAO 2' x 10" Fo % Pad Wen applied 2X4 ON COCE \- MM FIRST PAN hERE (WEN ACO!flONAL NANC 15 RCCt tR .0 O Br COOS) 2' X 10• ?oeo ?ad Shen applied NAIL COYER HERE (rMCN RCCIJIREO) Placement Detail #1: Two -Piece Barrel Profile Product Control No.: 9 2;L 4 1 9 (L Raul odriguez PLACEMENT DETAILS • (CONTINUED) OOij MINERAL SURFACE ROCF1N0 FELT 2- x 10' Town Pad whe applied SECURE . YAT'1 CCRROSION FASCIA BOARD �� i NA 15 (EPOU). PREFABRICATED CLOSURE NAILED 1HROUCH PLASTIC R00F CEMENT OR INTO APFROvZD AOHC5I'IE Placement Detail #2: 'S' Shaped Tile Profile 1 0 WEEPH Raul 1eidriguez wo.. -1 NAIL HERE - .1.e1CUC1+ PLASTIC RCCF CEMENT ('ht{EN A0017ICNAL NAU. 15 RECUIRED BY CCCE) ME! CLAP EARC Z. 80AR0 Sealar.t 0: POINT —UP ntrvt COLORED MORTAR TO a ATCM T1LC SURFACE ROLLED RAKE MLE (SPANISH 'S CUTS, PLACEMENT DETAILS (CONTINUED) FASCIA 8 0AR J 90/ 341INERAL SURFACE ROOFING FELT r x 10' torn Pad When epplled NAIL TriROUCM PLASTIC ROOF CEMENT coot) (MME? AOOITIOUM NAILING Is REQUIRED ar 9 AACE 80AR0 Placement Detail #3: Double Roll Profile 11 k roauct Control No.: 9f - 0:14 l kaullRodriguez a • • • FASCIA BOARD PLACEMENT DETAILS (CONTINUED) METAL CAVE DRIP 2' X 10' Foam Pad l*SA apP.ied NOTE: FORT: CONTACT 15 *IAOE WIN 3 TILES. 1. THE NEAO OF ONE TILE 2. THE UNOERLOCx SIDE OF A SECOND TILE 3. THE UNOERSIOE Of THE TILE BEING SET NAIL THROUCH PLASTIC ROOf CEMENT (WHEN A00I110NAL NAMING I5 REOUIREO aY CCOE) • DARCt 80AR0 POINTED -UP uCOTAR BED (WEN USING NO RAKE FIXTURES — FLAT TILE ONLY) SAw -CUT HALF TILE Placement Detail #4: Large Flat Profile l 2 Raul odriguez rroauct Lontrol No.: y q 121 • • PLACEMENT D ETAILS (CONTINUED) • MOTE: FTRIt SHALL NOT REACH OHIO TriE HEAO OF TILE IN PREVIOUS COURSE CR CiITO VNOENLOCX OF AOJACENT TILE. 2' x 10" 7carta pee! :; en appiied METAL EAvt ORIP TtdtC1( JTT TILE NOTE: FOAM CONTACT 15 MAO Y%TH 3 TILES :I BARGE BOAR° SA WCUT HALF Tit. FASCIA ROAR° • —2. THE UNOERLOCX SIDE 0 A SECOND TILE POINTFO —UP MORTAR SCO I. 71•IE HCA0 OF ONE TILE .3. THE UNOERSICE Cr • ME TILE 8EINC SCT • NAIL HERE THRCUCY. PIGS: Roar CEI/CHT CAHCN RCCUIR_C BY C00E) Placement Detail #5: Small Flat Profile 13 Rau / odrigucz .���L LonUOI Owner's Address PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date / 93 Job Address f6 90 /VC St ' Tax Legal Description (X / Owner / Lessee / Tenant /690 ,v64 �� ST. Contracting Co. g‘'J aPOLADI G � � _ P Address Qualifier e4LAt't° � i. i ii / Phone State # Municipal # 1.1€AA;ck Competency # Folio 1/ �a� 5 e" / /// � - .�- Master Permit 4� 3 Phone 4(/ a /*52 7 z. Ins.Co. Architect /Engineer Address Bonding Company Address Mortgagor Address Permit Type(circle one): WORK DESCRIPTION Square Ft. /4 Sp WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the,atibve -named contractor to do the work stated. Sign Lure of owner and /or Condo P': -ident Date: 9 - L4. 93 0, or C ommiden ' ' MY COMMISSION # CC 212726 1 ;; _ EXPIRES: July 6, 1996 • i i` a:` Bonded Thru Notary Public Underwriters ** * * * * * * * . • FEES: PERMIT 5/% ( g RADON as t My Commission APPROVED: BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN Mechanical CI} Estimated Cost(value) /V7J ,P. Date: 9 - .20 Notary My Comm. 2 Awl. It -‘ 0741 DV 6k41- - 3 Signature of ntractor or Owner- Builder cr IL uilder - A F. xi!'�etiS: i3'9 p CC 212726 EXPIRES: jury 6,1996 of F °p Bonded Thro Noun/ Public Underwriters * * * `. n s ir "" * ** N ■ C.C.F. 1' ✓r NOTARY TOTAL DUO / 1 Y ? Fire p Other 0 Electrical Plumbing Engineering Application is hereby wade for the approyaI of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. 0 � ^ 5� Date..._..._ — ..L 1' .._ .. _...._._......... ,11 Owner's Name and Address C _. .� .... No .... . Street.... Registered Architect and /or Engineer 1 / , .... ,,,,,,, ,,, , ,, , ,,,,1..1 . ..... Name and address of licensed contractor J . 1� ? .?.... ( Location and legal description of lot to be built on: Lot Block Subdivision STATE OF FLORIDA, COUNTY OF DADE. ss Disapproved (Signed) MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Date. Street and Number where work is to be done .J State work to be done and purpose of building (by floors) ✓ Remarks __._.__ (Signed). FL: 77 and for no other purpose. New Building Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Covering Estimated Total cost of improvements $ j 1 :• -• Amount of Permit $. Zone cubage required .Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer of labur under the Florida ‘Vorkmen's Compensation Act, being Section 5966, Compiled Gen aws of Flor' Inane/It Supplement, and has complied with the provisions thereof, and will require similar compliance from all ntract rs or su contract employed b him in the work to be performed under this permit; and will post or cause to be posted for i pection on the site the wok such publ' • notice or notices as are required by the Act. The undersigned agrees to employ only such su ntractors, .on work to performed un er this pennit, as are licensed by Miami Shores Village. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me .first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. �,� Permit No.._ YX46 Date t�1 II 1 a t'77 Read, Sworn to and Subscribed before me. to me well known, Notary Public, State of Florida uilding Inspector My Commission Expires PLANNING BOARD DATE Chairman Member Member Member Member ...... __.__._..._._ .._._ Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and/or workmanship. APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at budding during progress of the work. Owner's Name and Address ..... .> 12 1- - 1" . Registered Architect and /or Engineer Name and address of licensed contractor MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT , 19.. _. .; . _ O _ No./0 .. Street_A ( A 0 ... .ittttttt t!t V 6 7Q2 c5 c 5 . Location and legal description of lot to be built on: Lot Block Subdivision t ,� Street and Number where work is to be done / d 1© t � � a_ • . _..._ State work to be done and purpose of building (by floors) and for no other purpose. New Bui!ding C/ Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Covering / 3 © ' C ht g f 4 ' 0 /14 c7 Estimated Total cost of improvements $.d....O S Amount of Permit $, t r`�© w � ` � l 7 d c��. e a (, Zone cubage required plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the 'Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcottractors, on work to be performed under this pennit, as are licensed by Miami Shores Village. Remarks _ __.__ (Signed) Building Inspector My Commission Expires M tYr STATE OF FLORIDA, COUNTY OF DADE. SS. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. ff Permit No.._ X Q 1 3 Date...1 \ L " Read, Sworn to and Subscribed before me. Disapproved C......f Date.. _..__..._ Notary Public, State of Florida PLANNING BOARD DATE Chairman Member MIcrnbcr Member Member ...... Member �.._._._ Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application niter approval has been obtained frotn the Planning Board. A re- in .pcc•tion fee of 31.00 will be charged when such re- inspection is made necessary by improper notice for inspection at faulty materials and /or workmanship.