Loading...
WS-11-460INSTALLATION OF 18 IMPACT SLIDING WINDOWS & DOORS Passed c/ Inspector Comments ec- 7 Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Number: INSP- 157266 Permit Number: WS- 3- 11-460 I Inspection Date: May 12, 2011 Inspector: Bruhn, Norman Owner: REDMOND, KATHLEEN Job Address: 1010 NE 92 Street Miami Shores, FL Project: <NONE> Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Contractor: MIAMI BEACH COMMUNITY CONTRACTOR Building Department Comments May 13, 2011 For Inspections please call: (305)762 -4949 Permit Type: Windows /Shutters Inspection Type: Final Work Classification: Window /Door Replacement Phone Number Parcel Number 1132050130011 Phone: (305)538 -0900 Page 1 of 1 1 LK VI) BUILDING Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit No.V 1 l ---- 14 -CO PERMIT APPLICATION Master Permit No. FBC 20 Permit Type: BUILDING ROOFING OWNER: Name (Fee Simple Titleholder): k4 '/ / Address: /WO / 6 f Z f7-- / City: /!f /444 ad o x P,f". State: Tenant/Lessee Name: Email: KX /? / ri6 S Cl: JOB ADDRESS: ` ( d/: L ; 7 J7 - City: Miami Shores County: Miami Dade Folio/Parcel #: Is the Building Historically Designated: Yes NO ✓ Flood Zo CONTRACTOR: Compan Name /f/4W „,fa C,Om Usv G ' '1 phone#: 5 — ,-- v Address: 7VA fV eif/e4. H/, $4/4 Ale-- FAIC 3°° 3 City: /,/�( � r!.4 ' � State: r ` Zip: ‘ / Qualifier Name: 11 / ' L t C, /Q O y Phone#: 3DX �3f�90t' State Certification or Registration #: - ° G 0 "c 7 O G 7 Certificate of Competency #: 0 9 Pic-kJ Z Z Contact Phone#: 3(7 ( 3 2.-3 vCP AS Retail Address: 43B{j Z CO 4 • /ZS L., DESIGNER: Architect/Engineer: .,." Phone #: Value of Work for this Permit: $ /9/ COO Square/Linear Footage of Work: Type of Work: ❑Addition °Alteration New DRepair/Replace °Demolition Description of Work: 7 (-'e 6 4 IVr.v ?S 04-cl C r/''�'`7 AAA- 1�? C- *A 7 f7 -,vi) I 1V ( S2 1Z.) 7 3/4•Cr Phone#: pa:MTRZI' MAR 1 5 2011 B "°- '''' 0 ********** Phone#: iO(7f7 4.5 a Zip: ? Zip: ' ` �d 3 Submittal Fee $ Permit Fee $ Q( (7 CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) 1 1 Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature °d Sign: Print: APPROVED BY My Commission Exp Owner or Agent The foregoing instrument was acknowl ged b re me this The foregoing instrument was acknowledged before me day of O3' / p , 20 LL , by /(410 66"r`Yl') , day of °?-h9 , 20 // by 4 G 'Otte' de 6 who is personally known to me or who has prodfideT " C ' ce 'io is personally known to me or who has produceik f U strtost'ce-_ � � As identification and who did take an oath. f7 identification and who did take an oath. NOTARY PUBLIC: I NOTARY PUBLIC: .k 'Trujillo o ff " '• c - �ryg SS ■oNMp 26, 20 o Y 6 te ce aFRES: O 26,2013 ;, pip y \yW .N R , k****+R*+R , k$*+ **** *+ kHk****d **+ k*9e*He**** ***$ **+ kok**+i«**da**&*4e****tl *** do**+ k***dN **ak**+k+RNh****Ne**** (Revised 07 /10/07)(Revised 06/10/2009)(Revised 3/15/09) 4/4 Plans Examiner Structural Review Signatures ontractor i110 :, • Tru ` "' "`• D8 932U ?�og� ayeG �h1PMsS:0P1 # D 13 c=° 47 : ' Exp RES IdAY 26, 20 E' gARO NNOTA ��• .b;:� i,.c -: yV .. R' .coin • ••' n',' NtyV „ Zoning Clerk NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. W41 ! 3'" // / 4' 4AXF000NO. IG� ZOJ �(9t STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and In accordance with Chapter 713, Florida Statutes, the following Information is provided in this Notice of Commencement al description of proprty and str 'C dt � .. , ,�r /f , ' ,V Desirrip f mprovement. 3. Owner(s) O and ad Interest in property: Name and address of fee simple titleholder. 'P 4. Contractor's name, address and phone number 5. Surety: (Payment bond required by owner from contractor, H any) Name, address and phone number. Amount of bond $ _/ 4- 6. Lender's name and address: 444, 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes - yi Name, address ddress and phone number. / -i r 7C8 0eA . /t/Q qv.1 _4 r19ePsyetF3 PS 75'7 1 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided In Section 713.13(1)(b), Florida Statutes. Name, address and phone number. //4 • 9. Expiration date of this Notice of Commencement Signature(s) of Prepared By Print Name Title /Office VERIFICATION PURSUANT TO SECTION 82525, FLORIDA STATUTES Under penalties bf perjury, I declare that I have read the foregoing and that the facts stated in It are true, to the best of my knowledge and belief. /dress: /Ord STATE OFFLO` <' = -- , EXP' -S: AY26,2013 COUNTY OF MI -S Wrei AA'tJNNOTAR'Lcom ".1.4t7, `1 . • The foregoing instrument was acknowledged before me this � of By Eau. k T�l wi110 ❑ Individually, or ❑ as fof�•• ' e rr „i .ham. # r ► " 1.. ❑ Personally known, or ❑ produced the following type of Identi , "a . . 2013 i s Signature of Notary Public: lt; - d;•' , .% ..; . ; .' : •� Print Name: S•ama (SEAL) Signature ) . Owner(s By 129.01 PAGE 3/10 (the expiration date Is 1 year from the date of recording unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,' CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Offi rector/Partner/Manag Prepared By l '. ' Print Name . rs pet a Title/Office r p r va�,¢G d y e . Ty. y, d, T zed f p NDhector/Partner/Manager who signed above: ' " EXPIRES: MAY26, 2013 '44,,,,r .��` wawr .AgRoMNOTaRfr ,, OF FLORIDA, COUNTY OF DADS I HEREBY CERTIFY that than a true copy of the 'ngrnal filed in this office on day of APR 0 1 2011 • A D 20_,....."__ WITNESS my hand aal Seal. 'tARVEY ' UVIN. o Circuit and Canty Cants N dw L p ' - fi. • 4 L. D.C. wor 3 3 W5 11111111111111111111111111111111111111111E II E CF14 2011 OR Bk 2763E Ps 1245; (fps) RECORDED 04/01/2011 13 :52:2$ HARVEY RUVIN, CLERK. OF COURT MIAMI —DADE COUNTY. FLORIDA LAST PAGE Space above reserved for use of recording office ir9e!/ ceeP rag / / PRODUCER INSURER LIR Apr. 1. 2011 10:12AM Na. 0907 P. 10 �CORI1 CERTIFICATE OF LIABILITY INSURANCE DATE IMINDat Yr7) 04 01 11 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW, THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER {S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If t certificate holder Is an ADDITIONAL INSURED, the policypes) muss be endorsed. If SUBROGATION 1S WAIVE DT subJect to the terms and conditions of the policy, certain poticlee may require an endorsement. A statement on this certificate does not confer rights to the eertilicato holder In lieu of such endorsemenl(s). BROWN & MOWN OF FLORIDA INC 14900 Nff 79th Court Suite 9200 Miami Lakes FL 33016 - 5069 Phone:305- 364 -7800 Fax:305- 822.5687 COVERAGES THIS IS TO CERTIFY THAT THE Pt3.ICIE8 OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POIXTPETEOD INDICATED. NOTWITHSTANDINOANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE NSURA•ICE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL 'THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POUCIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. GENERAL LIABILITY A X COMISRCTAL GENERAL 14t81UTY WAIMS MADE a OCCUR BENLAOGREGAYE miff APPI.IES KR: 7 n AUTOMOBILE LIABILITY ANY AUTO ALL OWNED AUTOS SCHEDULED AUTOS WRED AUTOS NON -OWNED AUTOS Miami Beach Community 945 e�vl{r, Idi.+C� Miami Heath FL 33 13g TYPE OF INSURANCE UMSRELUA LIAR eXcESe LIAO DEDUCTIBLE RETENTION S WORKERS COMPENSATION AND EMPLOYERS' UABILITY Y IN OrPIOE� E (M In N$ OF OPERATIONS Deem CERTIFICATE HOLDER ACORD 25 (2009109) 1XAIMS -MADE VISA CIA Miami Shores Villages 10050 NE 2 Ave Miami Shores FL 33138 CERTIFICATE NUMBER: WWI GL850677 52032956 FUMY' MINDER N NAME: WOMB I NC. No, lEo1k • REM P MWIRWR NO 1; MIAMI5 9 INSURERA: Colony Insurance Company INSURER B : FLORIDA RETAIL FEDERATION INSURER C : INSURER D : _ INSURER E INSURER F : (MMIererr ) 09/06/10 03/09/11 (M 09/06/11 0 DESCRIPTION OF OPERATIONS LOCATIONS! (math ACO O 101,AddlUaa1RebmEiSchedule Umolt aglow leleq*Sd) CANCELLATION AUTHORIZED REPRESENTATIVE The ACORD name and logo are registered marks of ACORD INSURERS) AFFORDING COVERAGE NATO I REVISION NUMBER: EACH OCCURRENCE taewuie to tamtu PREMISES (Esaww.etroe) MED EXP (Any one wean) PERSONAL & ADV INJURY GENERAL AGGREGATE PRODUCTS- COMP!OP Aee COMBINED SINGLE LIMIT (6a actidenq BOXY SWAT (Per person) BODILY INJURY (Per sodden:) PROPERTY DAMAGE (Per a*denl) EALS4 OCCURRENCE AGGREGATE OP 1D KR 1989-2009 ACOR ' CORPORA 10 NO. Net LIMITS EL EACH ACCIDENT EL DISEASE - EA EMPLOYEE El. DISEASE - POLIGY MIT s 1,000,000 $100,000 $ excluded $1,000,000 $2,000,000 $2,000,000 S S S S S $ S S $ $ $500,000 $500,000 x 500,000 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL NE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. All rights reserved. r r LOCATION Existing Garage Door Miami Shores Village APPROVED BY DATE ZONING DEPT ONE STORY Z ESIDENC BLDG DEPT ` ' V T SUBJECT TO COMPLIANCE WITH ALL FEDERAL. STATE AND COUNTY RULES AND REGULATIONS FRONT DOOR I o T TO BE COVERED CITY 0 c • • • • • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • •• • • • • • • • • RAMC ENGINEERING, INC. FLORIDA BUILDING CODE, 2007. ASCE 7-05. EXPOSURE "C" LOAD TABLE FOR WINDOWS / DOORS TOTAL SQ.FT. 201.26 POS.PRESSURE NEG.PRESSURE MARK DESCRIPTION WIDTH HEIGHT TRIB.A. ZONE NO # P.S.F. P.S.F. 1 FIXED 26.5 74 13.62 45.59 -49.53 INT 07 -0201.05 2 FIXED 26.5 74 13.62 45.59 -49.53 INT 07 -0201.05 3 FIXED 26.5 74 13.62 45.59 -49.53 INT 07 -0201.05 4 FIXED 26.5 74 13.62 45.59 -49.53 INT 07 -0201.05 5 2- H.S. 13.25 63 5.80 46.52 -50.47 INT 1 07- 0813.08 6 2- H.S. 13.25 63 5.80 46.52 -50.47 INT 07-0813.08 7 2- H.S. 26.75 26 4.83 46.52 -50.47 INT 07- 0813.08 8 2- H.S. 26.5 48 8.83 46.52 -50.47 INT 1 07-0813.08 1 9 2- S.G.D. 36 80 20.00 44.43 - 48.37 INT 09-0210.07 10 2- S.G.D. 48 80 26.67 43.56 -47.50 INT 09-0210.07 11 FIXED 19 38 5.01 46.52 -50.47 INT 07-0201.05 12 2- S.G.D. 48 80 26.67 43.56 -47.50 INT 09 -0210.07 1 13 2- H.S. 18.75 63 8.20 46.52 -50.47 INT 07-0813.08 14 2- H.S. 18.75 63 8.20 46.52 -50.47 INT 07-0813.08 15 2- H.S. 18.75 63 8.20 46.52 -50.47 INT 07-0813.08 16 2- H.S. 26.75 50 9.29 46.52 -50.47 INT 07-0813.08 17 2- H.S. 26.75 50 9.29 46.52 -50.47 INT 07-0813.08 • • • •• ••• • •• •• • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • EXPOSURE ADJUSTMENTS .85 GENERAL NOTES: I. 2 CONTRACTOR TO VERIFY ALL DIMENSIONS 3. ASCE 7 -05 WIND CODE (146 MPH) EXP. "C" 4. FLORIDA BUILDING CODE, 2007 5 BUILDING'S MEAN ROOF HEIGHT : 15' G MIN. BUILDING WIDTH: 30' 7, ROOF INCL. I8 8, APLICABLE ZONE: 4 (INTERIOR). 9 OCCUPANCY IMPORTANCE FACTOR: 1.0 • • CONSTANT: 0.00256 • ,•10. GCPI : 0.18 ••• I I . Kd :.85 D. ITAWN BY • • • • • • • • • • • • • • • • • • • ••• • • • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • •• •• •• •• • • • •• •• • 000 • • • 000 • • • • 0 00 • • • 000 REVISIONS J cn z 0 J U � J LL. 0 co ct Q rn0 0 W (A J 0 Z O< r JOB No: edmond -bobs ir.wdw.11 SHEET MIAM COUNT'( BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) E.S. Windows, LLC 10653 N.E. Quaybridge Ct. Miami, FL 33138 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami Dade County Product ControlDivision and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (MD). This NOA shall not be valid after the expiration date stated below. The Miam -Dade ;County Product Control Division (In Miami Dade County) and/or the AM (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes If this product or miterial fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AID may immediately the use o f product within their BORA reserves the right to revoke modify, or suspend Miami-Dade Product Division that this product or to revoke this acceptance, if it is determined by material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series 4000 Aluminum Sliding Glass Darer —LMI APPROVAL DOCUMENT: Thawing No. W03 -100, titled "Series Aluminum Sliding Patio Door (LMI), sheets 1 through 8 of 8, prepared by Al -Fatooq Corporation, dated 11/08/03 and last revised on Jan 30, 2009, signed and sealed by Dr. Humayoun Farooq, P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant Limitation: 1. Exterior ( positive) design pram= are limited to +70 PSF w / 2-1/2" sill & +80 PSF w/ 3-1/4" sill LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement "Miami Dade County Product Control Approved", herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and them has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an emiorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. followed by ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and the expiration date may be displayed in advertising literature. If any pion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Buildingafficjid.. • as i T his NOA revises & renews NOA # 08- 0477 03 consists of this page 1 and eiridence pagq j, . approval doc ment mentioned above. . " • .. • • • • The submitted documentation was reviewed by Isbaq I. Chanda, P. E. ViN MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAMER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375.2901 FAX (305) 375 -2908 wwwaniamidade.gov/bu ldingc0de •.• ••• ••• ••• . • ,P404 No 0in1e.05 ExpinstfouVitte: Neer 2p4 ' Approval'Datel April 01i 2004 Page 1 1 • .• • • ; • • • • • •.• • • • • • •: • •• • • • •• • • • • • • •; •• ••• • • • • • • • • • • • • • • • • • • • • • .. E.S. Windows NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED • A. DRAWINGS (transferred from file # 08- 0477.03) 1. Manufacturer's die drawings and sections. Drawing No. W03 -100, titled "Series-4000 Aluminum Sliding Patio Door (LMI), sheets 1 through 8 of 8, prepared by Ad Farooq Corporation, dated 11/08/03 and last revised on Jan 30, 2009, signed and sealed by Dr. Humayoun Farooq, P.E. B. TESTS (transferred from file # 08- 0477.03) 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wmd Pressure Loading per FBC, TAS 203 -94 6) Forced Entry Test, per FBC 24113.2.1 and TAS 202-94 Along with marked-up drawings and installation diagram of an Aluminum Sliding Glass Door, prepared by Fenestration Testing Laboratory, Inc., Test Report No(s). FTL -3908, dated 10/09/03, FTL -3909, dated 09/26/03, FTL- 3910, dated 09/30/03 and FTL-4287, dated • 09/22/04, signed and sealed by Joseph Chan, P.E. and Test Report No. ffL -4287, dated 09/22/04, signed and sealed by Edmundo Largaespada, P.E. 2. Additional test No. FM-5471, dated 01/24/08, per TAS 201/203 -94, issued by Fenestration Testing Lab, signed & sealed by Michael Wenzel, P.E. C. CALCULATIONS 1. Anchor verification calculation dated 01- 19-09, complying w/ FBC 2007, prepared by Al- Farooq Corporation, signed and sealed by Dr. Humayoun Farooq, P.E. 2. Calculations, and structural analysis, prepared by Al Farooq Corporation, dated 04/16/08, signed and sealed by Dr. Humayoun Farooq, P.E.(file # 08-0477.03) 3. Glazing complies with ASTMS- 1300 -02 & -04. D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 01- 1204.01 issued to "EL DuPont DeNemours" for "Sentry Glass ® Plus" dated 01/17/02, expiring on 01/14/07. 2. Notice of Acceptance No. 07- 1116.04 issued to EL DuPont De Nemours & CO., Inc. for "DuPont SentryGlas ® Plus ", expiring on 01/14/2012. F. STATEMENTS 1. Statement letter of compliance w/FBC -2007, dated Jan 19, 2009, signed by Dr. Humayoun Farooq, P.E. 2. Statement letter of compliance and of no financial interest, dated 01/19/09, signed and sealed by Dr. Ha mar= Farooq, P.E. 3. Statement of Lab compliance, part of above test reports. G. OTHER .. 1. This NOA revises & renews NOA # 08- 0477.03, expiring Marci 1$ 2011.:: . • • 2. Previous related NOA(s) are NOA# 06-0606.02 and 04- 1117.p5a : .: j • • • •t L Chanda, P. E. ... 'pdueligo :.1 Examiner ]4OA,No 0902 do : Wirth • Apbroval» ate: itiprIl 01,449 E = 1 • • it kW. MEAD SILL CO 49 1/16' MAX. 1ST MAX. 192 MAX. e � drawing no. W03 -100 eo of : • SERIES•4000•ALTJM W • 1 • DESIGN LOAD RA NO FOR 50.ORS TOA BE AS PER CHARTS SHOWN ON SHF1 3. • Op _ .. p STED TO COMPLY WITH THE • • REI P IREME N � T TS OF THE SADE�Z004/ 007 EDITION INCLUDING • • • • r • HIGH YELaiiif HURBIGANE, ZOt(CA(I<M71 • ••• I • WOOD BUCKS , I CHORED PROPERLY TO TRANSFER • • LOADS TO THE STRUCTURE. ANCHORB•� E AS_US Q AS SHOWN ON DETAILS, ANCHORS • • EMBEDMENT TO SABE MATERIAL �rBEYOND. WALL DRESSING OR STUCCO. • • • • • i ANCHORIN% OR LOADING 0 NOT SHOWN IN THESE DETAILS • ARE NOT PART OF THIS AP� • A LOAD OU IR %CREASE IS OSSIIP BESGN OF ANCHORS INTO WOOD ONLY. • • MATERIAil BUT NOT PTO SIEELANTAL SCREWS, THAT COME INTO OF 2 12U L T P RIDA BLDG.-WEE G MEET THE REQUIREMENTS .... TYPICAL FLRVATION TESTED UNIT DOORS GLAZED WITH LAMINATED CLASS RATED FOR LARGE & SMALL MISSILE IMPACT AND REQUIRE NO SHUTTERS. PRODUCTRINEWED 4rwtu Asa p= . y., 0.07 EN:WNWWDs* _7TIM?,Pf Division ero3�o� DESIGN LOAD CAPACITY - POP (AU. 61 BB SHOWN B pR ThIS C SHEET) P' WM Noe c wo m80 NO REINFOR'G MEDIUM RBINPOR'G HEAVY REINP'0 EIR. (4) IN!. (-) ER!. ( +) NT. (-) EEL (+) INT. ( 1 aRVV3 80 70.0 80.0 70.0 80.0 70.0 80.0 • 70.0 80.0 70.0 80.0 70.0 80.0 - - 70.0 80.0 70.0 80.0 - - - - 70.0 80.0 - - - - 70.0 80.0 XXVVI SS ■ - 70.0 80.0 70.0 80.0 - - 70.0 80.0 70.0 80.0 - - - - 10.0 80.0 - - - - 70.0 80.0 • • • • • • • • • •• • • • II • • • • • • • •*. • • • • •• • • • • • • • • • •.:., • •• • • • • • • • ••• • • . •.•• • 1 -v• ••• • I • • XO (S OXO41IW1IN) • ox • • • • XXX • • xx •••• 3/I8 H.S. GLASS .080 INTER AVER 'DUPONT SUTACITE 3/18 H.S. GLASS TYPE 'H BtUCONE XXX (SHOWN) APPROWfl CONRHZURATION. oxxo XOXXOX;(10 0WN): XxXO (SHOWN) XXXX SEE SHEET 3 FOR 1:0 OR ES DOORS WITH HEAW REINFORCING USE SCHEDULE 'A' (SHEET 3) FOR ANCHORS ON ALL SIZES THIS CHART. PRODUCT RENEWED aaapbto BO* Cab d Shaft Jtaxplaw D 2b/N/ C b40 NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300 -02/04 (3 SEC. GUSTS) AND FLORIDA'BUILDINO COMMISSION DECLARATORY STATEMENT DCAOS- DEC -219 Ihr SOSMIUM HAMM rAA0a0 P1AeP Ur? a DBffiION AOR AO A - POP DIE CUSS TYPES 'A' OR 'B' PAM VIMII 8=168 mg mg a 431411 HEAVY REINP'° (SEE pyres- SHEEN 5) 81 1115 'A' 8CHEDUlE 'S' EET. (4) pNT. ( -) ExT. (4) NT. ( -) g4° :R so 80.0 103.0 80.0 103.0 80.0 103.0 80.0 103.0 80.0 103.0 80.0 103.0 80,0 103.0 80.0 103.0 30 39 98 80.0 103.0 80.0 103.0 80.0 999 80.0 103.0 30 38 100 80.0 103.0 80.0 103.0 00.0 95.0 80.0 103.0 • ••4 • Drawing na. W03 -100 • • • • 31 O L OPO. 3r PANEL TROTH • • • • • • • ••• • ••• • 8' MAL TYP • •..._. •••• • • • • . ,U 37 PAWL ROTH TYPICIAI Pi FVATI04( • • • •• • • • • • • • • • • • • ••••,.• •• \ • • • • • •••• •••• • • CLUSTER OF AN;XORS SEE OMB. BELOW SEE SHEET 2 FOR DOORS WITH MEDIUM OR NO REINFORCING THE SHOWN EXT. (+) LOADS MIRE 3-1/4' DU. HEIGHT (OIL 81 ON SHEET 4). REDUCE E1R. (4) LOAD CAPACITY TO +70,0 PRE 1? 2 -1/2' SILL HEIGHT IS USE° NT. ( -) 1.0505 REMAIN UICIWNGEO. ANCHOR WART WOOD CONCRETE BLOCK HEAD S81 JAMS HEAD DLL JAMB MOVIE 'A' 1/4' ANCHORS 1/4' ANCHORS 1/4' ANCHORS 1/4" ANW40R9 1/4' ANCHORS 1/4" ANCHORS swum 1' 8/18' ANCHORS 1/4' DIDIORS 1/4' ANCHORS 8/18' ANCHORS 1/4' ANCHORS 1/4' ANCHORS NOTE: AU. CUP ANCHORS - 1/4" DIA. (ITEM P10) MULLON ANCHORS • #12 SAS (NO SHIM SPACE) NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-02/04 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT OCAOS- DEC -219 mover wawa esa nods noteske M 9/15 MIN. WOOD BUCKS AND METAL STRUCTURE NOT BY E.S. WINDOWS MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCHORSI SEE ELEV. FOR SPACINo 1 /4 ° OR 5/18° DIA. ULTRACONS BY 'ELCO' (Fu -177 KS. Fy.1SS KS) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1 -1/2 MIN. PENETRATION INTO WOOD THRU IBY BUCKS INTO CONC. OR MASONRY 1 -1/4° MIN. EMBED INTO CONC. OR MASONRY DIRECTLY INTO CONC. OR MASONRY 1 -1/4° MIN. EMBED INTO CONC. OR MASONRY I/4" D1A_ TENS DR SELF DRRL4NO SCREWS PM s CRS) INTO METAL STRUCTURES STEEL 112 GA. MIN. (Fy - 38 KSI MIN.) ALUMINUM : 1/8 THK. MIN. (8083 -T8 MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) 1L2 SMS OR SELF DRILLING SCR EI INTO MIAMI -DADE COUNTY APPROVED MULLIONS (MIN. THK. + 1/81 (NO SHIM SPACE) YIa. EDGE DISTANCES INTO CONCRETE AND MASONRY - 2 -1/2" MIN. INTO WOOD STRUCTURE - SEE NAIL (A) INTO METAL STRUCTURE • 3/4 MIN. CONCRETE Fs ■ WOO PSI MIN. MASONRY rm . 1800 PSI WIN. ,SEALANT; AU. JOINTS AND FRAME CONNECTIONS SEALED WITH WHITE /ALUMINUM COLORED SILICONE. WEEPHOLES; WI - 1 -3/4° WEEP NOTCH AT EACH END W2 - 3/4 WEEP NOTCH AT EACH END W3 - 3" X 1/4 WEEP HOLES AT 2" FROM EACH END • • • • el • •41414 ....:.. 1 /4 ° MAX. S• ..f• • • •••• .••• WAVY RF.INFORCINQ AT INTERLOCK & ASTRAGAL STILES drawing W03 -100 • Mira: • •.1 •• ; .• • 4 • • • • • • • •••1 •• • • • '/� s • i.•vi+ vim • • JAN S 0 ZOOS (lima! 5 of 8) • •••• • • • • ••••N • • •••4 • ••••4 • • • • ' • • • •• 1• Lv • • • • _`_i dGae_. rr 7�IM wsm�, �il r aYr • • ••• ••• ••• •••• • •• SCREDI OPTIr - -- MEDIUM REINFORCING AT EXT. INTERLOCK & ASTRAGAL STILES • •• • • • R FORCIN •••• N ITEM # 1 2 IA 3 4 S 6 7 8 9 10 13 14 144 15 18 17 19 19A 20 21 23 24 26 2T 25 29 2SA 30 31 32 33 34 PART # ES- 4001 -1 ES- 4402 -1 ES- 4003 -1 ES-4004-1 ES- 4005 -1 ES- 4000 -1 ES- 4097 -1 ES-4008 00 -4009 E6 -4010 ES -4013 ES -4014 ES -4019 623241M 028647DX E8 -4015 /10X1 -1/4' PH MS 10X1' FK SMB TA -35- 1935 -4201 #10X1 -1/4" PH SMS 2-1000 537 #10 PH SMS #6232 284026 ES -4017 28 -4020 #10111/2" PH EMS P38024411 gWANTTTY 1 2/ PANEL AS ROE. AS REOD. AS REED. AS REED. 2/ PANEL 2/ PANEL AS 2200. AS READ. AS REC. AS REOD. AS REED. AS RECD. 8/ PANEL 2/ CORNER 2/ MEN. PANEL 1/ ROLLER 1/ MOV. PANEL 2/ LOOM 1/ LOCK 2/ LOCK 1/ LOCX AS 0200. 2/ PANEL 2/ PANEL 2/ OUP AS REOD. AS RE00. AS (GOD. 2/ SIDE DESCRIPTION FRAME HERO STD. FRAME ELI. HI-RISE FRAME SILL FRAME JAMB TOP AND BOTTOM RAIL LOCK SEE WTERL0d1 FEMALE ASTRAGAL TOP & BOTTOM RAG. STIFFENER PANEL GUIDE (TOP ONLY) RETAINER CUP, 8' LONG GLAZING UNE BOTTOM RAIL GLASS STOP WcONE STOP STILE & JAMB W'STRPPING TOP RAIL W'BTRPPIN0 80TTOM PAIL 117RRIPPING PMEL ASSY SCREWS FRAME ASSY SCREWS GLASS PANEL ROLLER ASSY. ROLLER INST. SCREWS MORTISE LOCK LOCH INSTALLATION SCREW LOIN STRIKE PLATE STRIKE PLATE MOUNT. SORER SREROR AND arum PULL SILL RISER FIXED PANEL CUP (OUTSIDE PANEL) FIXED PANEL CLIP (INSIDE PANEL) N9t8D PANEL CUP MEMO 1/4" X 1 -1/2" REINFORCING BAR 1/2" X 1 -1/2" REINFORCING BAR 3' LONG SELF ADHESIVE PILE PAD SUWON MATERIAL 6063 -T8 8083 -T8 6083 -T8 6083 -T9 6063-TB 8083 -T5 8083 -T5 0083 -T5 6083 -TB 0063 -TB VINYL ST. STEEL ST. STEEL PLATED STEEL 6083 -T6 8063 -TB 8003 --T5 STEEL. STEEL. WOO. MANP. /SUPPLIER /RENAL NOT SHOWN GLASS PANELS. ULTRAFAB GLASS PANELS, ULTRAFAB GLASS PANELS OARS PANELS I -1/4" 0.0. WELLS GLASS PANELS ONLY 0-32 X 1/2" PH MS, ST. STEEL NOT SHOWN (3) #6 -32 X 1/2" EH MS. ST. STEEL FOR 0X0 00088 AT HEAD AND BILL �. 6UM& FLA. PI L0557 X341. SOM PEODUCTIUMEWED N° a Iblimoks .01 • • ••1••• • • ••N••• • • •••W•• ••••• • R •• • •• JAN • • •••R•• • • .••.•. • • • •••• • • • • • 10 94 RLLEO FIX. PA■EI. CUP J/a x r x .090 ALUM ANGLE MX. PANEL CUP 3/4 X X .090' • ALUM ANGLE • • / • 2 ° P NS X 10 SMG 2 7'EO LEG FAL PANEL CUP ALUM ANGLE 090' O NOM USE INTERLOCK b ASTRAGAL TASLE says 2 • 3 x XOX OX CONrIG1JRATIQAI mom= ggNgwS• p2t Rarb.91•tlI Auchusatiocf < ,i ZI O • Eisphlka • • 4 • .• ••. S. • • • • • •. •• • . •.. • • • 1.830 1.812 4.511 FRAME HEAD 1 I 1 1.317 PANEL TOP /BOTTOM RAIL 1.499 1,512 drawing no. W03 -100 1.374 1.374 1.124 OO LOCK STILE 1.610 2.750 1.878 .082 1.812 ASTRAGAL STILE SILL RISER 2.183 .050 1.972 ASTRAGAL REINFORCING 31 INTERLOCK REINFORCINGS 1385 OUTSIDE PANEL FIXED PANEL CUP INSIDE PANEL FIXED PANEL CUP FRAME TOP CORNER • • Oa RETAINER VI • •••• •••• • • • • • • • • • • .050 2.248 • 59 • SCR&ER T6PleorrON RAIL • Ari DADE COUNTY BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Cury -A -Tech Corporation 930 West 23 Street Hialeah, FL 33010 SCOPE: MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 www.buldinacodeon line.com This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series 940 Aluminum Horizontal Sliding Window — L.M.I. APPROVAL DOCUMENT: Drawing No. W07 -59, titled "Series -940 Alum. Horizontal Rolling Wdw. (L.M.I.) ", sheets 1 through 4 of 4, dated 08/06/07, prepared by Al- Farooq Corporation, signed and sealed by Humayoun Farooq, P.E., bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the nlanufaetuler o. i : : • • • distributors and shall be available for inspection at theyob Buiang•011cipl.: •: • • This NOA consists of this page 1 and evidence page E, v as iglllapWtbval g1ogytheat Zndhttottleal=oie... • The submitted documentation was reviewed by Manuel Perez, P.E. ••• ••• • • • • • • e . • • • ••• eve S.. •e• oboe • • • • ••• ••• • • • • e .e• • •• ••• • • ••e e e • • • • • It sloe • • • • • e • • • :' ::: .: 1QI'lA Iwo: 07-0813.d8I.' Expiration Date: September 27, 2012 ... Approval Date: September 27, 2007 ••• • • •ee �agea ir 411 . • e • • • • • • :. • • : • ••• • • • • • e • • S • 5 5 5 5S • • • e • • • •• •• • e •• •• •• • • • • obe e• 000 • • • • • • ••• • Cury -A -Tech Corporation NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No W07 -59, Sheets 1 through 4 of 4, titled "Series -940 Alum. Horizontal Rolling Wdw. (L.M.I.) ", dated 08/06/07, prepared by Al- Farooq Corporation, signed and sealed by Humayoun Farooq, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202 -94 along with marked -up drawings and installation diagram of a horizontal rolling window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL- 5262, dated 07/14/07, signed and sealed by Carlos S. Rionda, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC -2004, prepared by Al- Farooq Corporation, dated 08/01/07, signed and sealed by Humayoun Farooq, P.E. Complies with ASTM E1300 -02 D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 06- 1205.10 issued to E.I. DuPont DeNemours & Co., Inc. for their "DuPont Sentry Glass ® Plus" dated 02/15/07, expiring on 01/14/08. 2. Notice of Acceptance No. 03- 0225.10 issued to Glasslam NGI Inc. for their "Safety - Plus II - Laminated Glass" dated 08/07/03, expiring on 08/07/08. 3. Notice of Acceptance No. 06- 0216.06 issued to Solutia Inc. for their "Saflex IIIG clear or colored Interlayer" dated 05/04/06, expiring on 05/21/11. F. STATEMENTS 1. Statement letter of conformance, dated August 1, 2007, signed and sealed by Humayoun Farooq, P.E. 2. Statement letter of no financial interest, dated August I, 2007, signed and sealed by Humayoun Farooq, P.E. 3. Laboratory compliance letter for Test rIq FTL. 5262 "' sxad ly Fenestnstion • • Testing Laboratory, Inc., dated 07/17/07, signed i a d ieeled by Catlps RRo id ,1'.E •• OOOOO ... • G. O 1. None. • • . • • • • • • • • • ••• ••• • • • • • • •• • • • • • •• •• • • E 5 • 5 • • • • • • • • • • • • • • ••• • • • • • • • •• •• • • ••• • • • • Lie o• •. • ••• negiPer • • • • • ii� Up� C .y oIIt - • ,•• -i • ice' • •• • • NOA Mt 07 i> .1: • Expiration Date: September 27, 2012 ApproyyiDpte: y §eutepii q,27.200'j • •• • • • • • • • • •• • • ••• • • • • ••• • • • • • • • • • •• •• •• •• • • • •• •• • • ••• • • • ••• • .• • • •• • • • • 8' MAX TYP. HEAD /SILL CORNERS • • 0 .41 0 •• •• MEAD/ It MAX. 34 1/18 ELL OPG. 37 1/8' VENT WIDTTHH WIDTH • • • • TYPICAL ELEVATION • TESTED UNIT • r •••••• • • • i • • 33 15/18' D.L OPG. S S- • • ALiJM N HORIZON S IDING WINDOW APPROVAI•APOLIEO TO SINGLE UNITS•OR SIDE BY SIDE • • COMBINATIONS OF•H.S./HS. SI! INIRIZONTAL SUDING WITH OTHER • • WINDOW TYPJS IN MODULE% 9 MORE WINDOWS USING MIAMI -DADE COUNTY APPROVED• UWONS IN BETWEEN. LOWER OBBIGN CRESSURE WOW VIINSOWS OR MUWON APPROVAL • • • • WILL AFrLrTdARRE SYSSEM. 4141 w•• • • • • 1.• • • •THIS PROW NA! BEEN DESIGNED MID TESTED TO COMPLY WITH TH REQUIREOIS IT8.Of•IHE FLORIDA BUILDING CODE 2004 EDITION INCLUDING *se' • • HIGH VELOUR tatIRCANE 2011 Ora). • WOOD BUCK! BY OTHERS, MUST•BEVENCHORED PROPERLY TO TRANSFER • •••• • LOADS TO STRUCTURE. • • • • ANCHORSD SHALL BS AS USIA SPSCED AS SHOWN ON DETAILS, ANCHORS see • • • EMBEDMENT•TO Bfi! MATERIAL�d• BE•BEYOND WALL DRESSING OR STUCCO. • • • • ANCHORING OR WADING COMEIROSIS NOT SHOWN IN THESE DETAILS ARE NOP PATH• SF•THIS APPROVAL • • • • • • • A LOAD DURATION INCREASE IN ALLOWABLE STRESS IS USED IN DESIGN OF • • ANCHORS INTO WOOD ONLY, " " "'� • • • • • MATERIALS NOWOII{C.BUT NOT y861Td1•Tp jTEEL/METAL SCREWS, THAT COME INTO • CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS • • Of 2004•FIDRIUA BLDG. CODE SECTION 2003.8.4. • • • •••• - - ••• • • • • FALSE MUNTINS SURFACE APPLIED OPTIONAL 1/8' H.S. GLASS OPTIONAL STRUCTURAL CHANNEL APPLED 090" INTERLAYER SAFLEX /KEEPSAFE MAXIMUM BY 'SOLUWA' OR SAFETY PLUS BY 'OLASSIAM' OR SENTRYGLAS PLUS BY 'DUPONT' 1/8' H.S. GLASS THESE WINDOWS ARE RATED FOR LARGE MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. DESIGN LAMD CAPACITY - PSI" (50 OR OX SEES) WINDOW DIMS. WIDTH 26 -1/2' 3r 53 -1/8' 74' 28 -1 /r 37' 83 -1/8 74' 28 -1/2' 3r 53 -1/8' 74" 28-1/r 3r 53 -1 /8' 74' 24' 38' 48' so' 72' 24' 38' 48° 60' 72' 24' 38' 48' so" 72' 24' 38' 48' 60' 72' HEIGHT 26' 38 -3/8' 50 -5/8' 63' 24° 38' 48' so° WITHOUT SHEAR COP EXT.( +) 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 88.7 58.7 70.0 85.5 49.7 40.4 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 85.4 70.0 70.0 57.2 49.2 44.3 70.0 70.0 70.0 10.0 70.0 70.0 70.0 70.0 70.0 70.0 88.7 88.7 70.0 88.8 49.7 40.4 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 65.4 70.0 70.0 57.2 49.2 44.3 WITH MAR CLIP EXT.( +) INT.( - ) 70.0 I 70.0 70.0 70.0 704 70.0 70.0 I 70.0 70.0 70.0 70.0 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70A 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 70.0 I 70.0 NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300 -02 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05- DEC -219 top DR. HINAVOUN ST11 FAR000 P14 PE AUG 0 7 2007 Approved n complying wl11 the BARN( L6ete NOM i i1".Ug,WW..); drawing no W07 -59 (sheet 1 of 4 • • • ••► • •* ••• • • • • • • • N••••• M •••• •• •• • • •••• • • • • • •• Mfr �c•.� f: ••• • • gin••• • • '• < A CAL ANCHORS • SEE ELEV. FOR SPACING .a '__ BT. • ^ •••• • PRECAST SILL • • FOR PACITY USE COOUM1J•STOUT SHEAR CUP ONLY IV MP •_ - - - ACITY CLIPS TYPICAL ANCHORS SEE ELEV. FOR SPACING TYPICAL ANCHORS SEE ELEVS. FOR SPACING 2GY WOOD BUCK MIAMI -DADE COUNTY APPROVED MUWON & MUWON ANCHORS SEE SEPARATE NOA TYPICAL ANCHORS SEE ELEV. FOR SPACING TYPICAL ANCHORS SEE ELEV. FOR SPACING TYPICAL ANCHORS; SEE ELEV. FOR SPACING 1/4 TAPCONS BY 'ELCO' INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1 -3/8 MIN. PENETRATION INTO WOOD THRU 18Y BUCKS INTO CONC. OR MASONRY 1 -1/4 MIN. EMBED INTO CONC. OR MASONRY DIRECTLY INTO CONC. OR MASONRY C. OR $14 SMS OR SELF DRILLING SCREWS INTO METAL STRUCTURES STEEL : 12 GA. MIN. (Fy = 36 KSI MIN.) ALUMINUM : 1/8 THK. MIN. (6063 -T5 MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) ,#t4 SMS ORS F DRI LING SCREWS INTO DADE COUNTY APPROVED MULLIONS (MIN. THK. = .0801 (NO SHIM SPACE) 11' ./1.11 :. INTO— CONGREFE - M0 MASONRY = 1 -3/4 MI PT AT REP CAST S 0J WOOD STRUCTURE = 1 MIN. k �• • ETAL STRUCTURE = -2 E a. MEETING _ • INS ` TION REINS AMBS- SEA6ES S WOOD BUCKS AND METAL STRUCTURES NOT BY CURV -A -TECH MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. W1 - 3/8 NOTCH IN LEG AT EACH END W2 - 3/16" X 2" NOTCH 4 PER SILL W3 - 3/18 X 2 NOTCH 3 AT XO & OX SIZES OPEN CELL FOAM PAD (1/2"X 3/4"X 3 -1/4") AT EACH W3 W4 - 1/2 X 1/8 NOTCH AT SILL TRACK AT 1 -1/4 FROM EACH END (XO OR OX SIZES) ei 82x 0 I i drawing no. W07 -59 4) • • • • //4.91• • • • • • •••• • • • • •.• • ••• • • . • • • • •• • . • : lo g E• • • • • S. • • TYPIQ • •••• • • LSEE KG • •••• • • • •••• • •• •• • • • • • • • • 2 3 4 5 8 7 8 10 11 12 13 14 15 18 17 18 i8A 19 20 21 PART # 10248 10845 10847 11822 10846 10250 10287 11823 C -3055 #8X1 10255 0-3081 0-3057 #8 X 3 QUANTITY 1 1 2 I/ VENT 1 2/ VENT 1/ VENT 2/ VENT 1/ VENT 4/ VENT 2/ VENT 4/ VENT C -3058 C -3085 2/ WINDOW AS READ. AS READ. AS RE00. 995 7918 -187 2 0. 04 4 3/ VENT 1/ VENT AS READ. DESCRIPTION FRAME HEAD FRAME SILL FRAME JAMBS H.D. FIXED MEETING RAIL SILL TRACK VENT TOP /BOTTOM RAIL 5/18• BOX SCREEN VENT SIDE RAIL H.D. VENT INTERLOCK RAIL WHEEL HOUSING & GUIDE ' ROLLER PIN VENT FACE GUIDE WEEEPHOLE HOUSING & FLAP ROLL FORMED GAZING BEAD GLAZING COMPOUND FINSEAL WEATHER STRIP ASSEMBLY SCREWS SWEEP LATCH AS REED. 2/ VENT ALUMINUM VENT LATCH LATCH SPRING CUP BRASS ROLLER FIX. RAIL BOTTOM SCREW SHEAR CUP MATERIAL 808375 8083 —T9 9083 —TB 8083 —T8 8083 —T5 6063 —T8 8083 -TB 9063 —T8 NYLON ST. STEEL NYLON NYLON OR CELCON ALUMINUM SILICONE ZAMAK 8063 —T8 ST. STEEL 6083 —T8 HAND. /BUPPUER DOW CORNING PHP SUS AT 7 -1/4' FROM EACH END 2' LONG Xo TAYOU OX OPPOSITE / f I / / TYPICAL FUR ANCHORS TYPICAL ANCHORS E ELEV. F • G 8 8 �I A . drawing no. W07 -59 (sheet 3of 4 FRAME HFAQ Q 8083-TT8 1.128 • .. •• • • •• ••.••• J I 1.002 - 1.8847 ••• • • •• • • • 943 .. . -.24O • • 3.312 • 2.312••.• • • • • • f" •••• .080 •5•••• 1 j • s f J • SHEAR CUP •• •• • •• .l - • .. N • �• 8083 -18 • • • MIME -Ufa S• •I. •1 • • .. lOE • %• •• - .•.• ••• • • • FRAMF TOP CORNER in MI BURRING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION MIAMI-DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375-2908 www.buildingcodeonline.com NOTICE OF ACCEPTANCE (NOA) Cury -A -Tech Corporation 930 West 23r Street Hialeah, FL 33010 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Cade , including High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Series 930 Aluminum Fixed Window - Impact APPROVAL DOCUMENT: Drawing No. W07 -01, titled "Series -930 Aluminum Fixed Window (LMI.) ", sheets 1 through 5 of 5, prepared by Al Farooq Corporation, dated 01 -18 -2007, signed and sealed by Dr. Humayoun Farooq, P.E., bearing the Miami Dade County Product Control Approval stamp with the Notice of Acceptance number and Approval date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA: Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official, • • • • • • • • • • This NOA consists o f t h i s p a g e 1 a n d e v i d e n c e p a g e as w e l l as a p p r o v a l d o c u m e n t m i u t i o n n 4 a b b e . . ... • The submitted documentation was reviewed by Ishaq I. Chanda, P.E. • ••••••• • •• ••• •• • • • •• ••• • .• ••• .•• • • • • • • • • • • • • • • • •• • • •• • • • • NOA No 074201.05 Expiration Date: April 12, 2012 Appso lJ ate;,ApI1 PIP • • • • • • 1 • • • . •.. rid • • • • • • • • • • • • •• ••• • • • •• ••• ••• • • • • ••• • • • • • • • ••• • • • • • Cury -A -Tech Corporation NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. W07 - 01, titled "Series -930 Aluminum Fixed Window (LML) ", sheets 1 through 5 of 5, prepared by Al Farooq Corporation, dated 01 -18 -2007, signed and sealed by Dr. Humayoun Farooq, P.E. B. TESTS 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test, per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading, per FBC, TAS 203 -94 Along with marked -up drawings and installation diagram of an aluminum fixed window, prepared by Fenestration Testing Laboratories, Test Report No. FTL 5073(FTL06162), dated 10/23/06 and FTL 5074(FTL06163) dated 11/09/06, both signed and sealed by Edmundo Lagaespada, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, prepared by Al Farooq Corporation, dated 01/18/07 signed and sealed by Dr. Humayoun Farooq, P.E. 2, Glazing complies w/ ASTME- 1300 -02 D. QUALITY ASSURANCE BY: 1. Miami - Dade County Building Code Compliance Office (BCCO) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 03 - 0421.01 issued to Solutia Inc for "Solutia interlayer for laminated Glass ", expiring on 03/04/09. 2. Notice of Acceptance No. 03 - 0916.02 issued to Glasslam NGI, dba Nebula Glass for "Safety Plus II", expiring on.08 -07 -2008. 3. Notice of Acceptance No.06 1205.10 issued to E.I. DuPont DeNemours for "Sentry Glass® plus ", expiring on.01 -14 -2008. F. STATEMENTS 1. Statement letter of conformance and "No financial interest ", dated 09 /18/03, signed and sealed by Dr. Humayoun Farooq, P.E. 2. Laboratory compliance statements, part of respective test reports. G. OTHER 1. Test proposal dated Feb 08, 2006 approved by BCCO. E -1 • •• ••• • • • • • •• • • • • • • • • •• ••• •• • • • •• Iskt�. t. C.4a • q I. • (3harra, P. • • • • odds Co2trvl E nmtbner • • • • • NOA No 070201.05 • • • • Expiration Date: April 12, 2012 APprPY0 I?ate: t�liF 7tr • • • • • • • • • • • • • • • • • • • •••• • • • • • • • • • • • • • • • • • • • • • ••• ••• • • • ••• ••• ••• • • • ••• • • as WINDOW WIDTH WINDOW WIDTH WINDOW WIDTH • • • WINDOW WIDTH WINDOW WIDTH • •••-••• •-•S• •-•1"" • ALLOWABLE LOADS FIA ALTERNATE SHOWN ABOVE OR SIMILAR CAN BE • VERIFIED BY intiltiNg PICTURE WITHIN SQUARE OR RECTANGLE AS • i ( prow IN DOTTE%On AND OBT I &lc LE LOADS FROM THOSE SHAPES. • • SERIES 930 ALUMINUM FIXED WINDOW APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF FIXED /FIXED OR FIXED WITH OTHER MIAMI —DADE COUNTY APPR'D WINDOWS USING MIAMI —DADE COUNTY APPROVED MUWONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MUWON APPROVAL WILL APPLY TO ENTIRE SYSTEM. DESIGN LOAD RATING FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEET 2. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 2004 EDITION INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. ANCHORS SHALL BE AS USTED, SPACED AS SHOWN ON DETAILS, ANCHORS EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL A LOAD DURATION INCREASE IN ALLOWABLE STRESS IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. MATERWLS INCLUDING 911T NOT LIMITED TO STEEL/METAL SCREWS. THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF 2004 FLORIDA BLDG. CODE SECTION 2003.8.4. 7 1 J r THESE WINDOWS ARE RATED FOR LARGE MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. Engr: OR. kUMAYOUN FAROOO STRUCTURES RA. CAJ+. 7535 8 2007 HEIGHT — 4.125" E WIDTH — 4.125" fa ‘ u U I N is drawing no. W07 -01 ¶ • • • •• • • • • • • • DESIGN LOAD CAPACITY - PEP WINDOW DIMS. WIDTH 18 24' 30' 38' 42' 4e' 84' 8o' 18' 24' 30' 38 42 48' 64' 80' 18' 24' 30' 38' 42' 48' 84' 80 18' 24' 30' 38 42' 48' 84 80' 18' 24' 30' 38' 42' 48 84' ii' 6 S 8 .• • 38' • • 4 Z• 48' • .IW• 24' • 49v. s .• •.8Y• • 48. LENGTH 48' 84' 80 88' 72' 78' • GLASS TYPES 'A', 'B' OR 'C' EXT. (4) 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 71.1 71.1 80.0 80.0 80.0 80.0 80.0 80.0 71.1 84.0 80.0 80.0 80.0 80.0 80.0 80.0 71.1 84.0 80.0 80.0 80.0 80.0 80.0 80.0 • •• *VA • ✓ 84.0 • 80.0• • •B9.,• • 80.0 •804 INT. (-) 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 71.1 71.1 80.0 80.0 80.0 80.0 80.0 80.0 71.1 84.0 80.0 80.0 80.0 80.0 80.0 80.0 71.1 84.0 80.0 80.0 80.0 80.0 80.0 80.0 71.1 84.0 • 80.0 80.0 80.0; 80.0 • GLASS TYPE EXT. CO INT. (-) 704 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 90.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 •• 80.0 • 80.0 •• -•• 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 Al • • • • 70.0 • 70. 0 70.0 • 70.0 J0.0 • 70.0 • 90I0• • 70.0 • MA• 80.0 • • • 71.T • 71.1 - - 80.0 • 80.0 •4NB0• 70.0 • 80.0 . jq.0 70.0 . 60.0 80.0 70.0 70.0 • 80.0 80.0 .BSA• 80.0 ••.•• • ••••• •.•• • • • • • • • DESIGN LOAD CAPACITY - PSI? WINDOW DIMS. WIDTH 18" 24' 30' 36' 42' 48' 18 24' 30' 36 42 LENGTH 9o' 9s' GLASS TYPES 'A', 'B' OR 'C' EXT. l +) 800 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 INT. C -) 80.0 80.0 80.0 804 80.0 80.0 80.0 80.0 80.0 80.0 80.0 GLASS TYPE EXT. (4) 70.0 70.0 70.0 70.0 70.0 70.0 INT. C -) 70.0 70.0 70.0 70.0 70.0 70.0 NOTE: GLASS CAPACRIES ON THIS SHEET ARE BASED ON ASTM E1300 -02 (3 SEC. GUSTS). 3/18' HEAT STREN'D GLASS .080' INTERLAYER SAF EX KEEPSAFE MAXIMUM BY SOLUTIA GLASS TYPE 'A' 3/18° HEAT STREN'D GLASS SILICONE DOW CORNING 995 k GLASS TYPE 'B' .100' INTERLAYER SAFETY PLUS II BY GLASSLAM 3/18 HEAT STREN'D SIU ONE DOW CORNING ID WAND LENGTH DIMENSIONS CAN BE ORIENTED VERTICALLY OR HORIZONTALLY AS SHOWN ABOVE. ITI4•9 1.1-1.04AI, 3/16' HEAT STREN'D GLASS 3/18 D GLASS 3/18' ANN. GLASS .100' INTERLAYER SAFETY PLUS II BY GLASSIAM 3/18' ANN. GLASS GLASS TYPE 'D' SILICONE DOW CORNING 988 • N 0 u 0111 oiiio CI x drawing no. W07 -01 (sheet 2of 5 ) • • • • • •••• • •••• TYPICAL ANCHORS SEE ELEV. FOR SPACING • 10111 • ••.. • . • • • • • ••• •••• • • 1BY WOOD BUCK IV:CCAL ANCHORS SEE ELEV. FOR SPACING TYPICAL ANCHORS SEE EMS. FOR SPACING SEE ELEVS. FOR SPACING pAgW -1d111M n A1A.ILtL _ MWAI —DADE COUNTY APPROVED MUWON & MULLION ANCHORS SEE SEPARATE NOA I WOOD BUCKS AND METAL STRUCTURE NOT BY CURV —A —TECH MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. 1/4' TAPCONC TYPICAL ANCHORS: SEE ELEV. FOR SPACING ...�... :T a - a.. 1 -3/8" MIN. PENETRATION INTO WOOD U 1BY BUCKS 1 - EMBED INTO CONC. OR MASONRY DIRECTLY INTO CONC. OR MASONRY 1 -1/4' MIN. EMBED INTO CONC. OR MASONRY 014 SMS OR SELF DRILLING SCRIMS INTO METAL STRUCTURES STEEL : 12 OA. MIN. (Fy = 38 KSI MIN.) ALUMINUM : 1/8" THK. MIN. (8083 —T5 MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) 1.1 a1 ORS F DWI I NG SCREt1PS INTO MIAMI —DADE COUNTY APPROVED MUWONS (NO SHIM SPACE) ANCHOR EDGE DISTMC INTO CONCRETE AND MASONRY = 1 -1/4' MIN. INTO WOOD STRUCTURE = 3/4" MIN. INTO METAL STRUCTURE = 1/2" MIN. SEALANTS: FRAME CORNERS AND INSTALLATION SCREWS SEALED WITH SILICONE SEALANT. Engn DR. HUMAY0101 FAAOGO EGRUCTOREN RA. PE #_218557 VAX. MN , .JA 007 drawing no. W07 -01 sheet 3o1 tg • • •••• • • • • • • •• •4•••• • • • • • • • • • • • • •••• •1 •••• • • • • •••• • • • •... • •• • • • • • •••. • • • • MIAMI -CADE COUNTY MULLION SEE SARA ANOA 4 • • • • • / •1 •••• •• • •• •• • • • • • 4 •••• • •• • • 4 •••• • •••• • • WINDOW WIDTH WINDOW WIDTH TYPICAL ANCH SEE ELEV. FOR e1 154 *a 1 'inn OR. HUMAYOUN FAROOO ERRUCRAIEB FLA. PE 1 JAN 18 20U7 ,--. 1 k W07 -01 (shee 4 of g ITEM NO. PART NUMBER QUANTITY DESCRIPTION MATERIAL MANP. /SUPUIER /EEMARIES 1 CU701 4 WINDOW FRAME 8053 -TB - n 11 a _ S -03083 4 GLAZING STOP 8083 -T5 - - AS REDD. SHEAR CUPS, 2° LONG 8083 -TB AT ANCHOR LOCATIONS DC 995 AS RECD. GLAZING COMPOUND SILICONE - 8 - AS RECD. SETTING BLOCK - - • • • •••• • • • •••• • • •••• •• •• • • •••• • • • •••• • • • •••• • • •••• • • • •• • • • • • • • • • • • • • • •• • •• •• • • • • • • •• • •••• • • • • •••• • •••• • • ••• •••• • • • •• • • • • • SPOT WELDED JOINT MITERED CORNER (OPTIONAL) RECT. OR SQUARE WINDOWS TYP. CORNER DETAILS drawing no. W07 -01