BPP-07-1620 (2)`LEGEND OF SURVEY ABBREVIATIONS
A ARC DISTANCt A/C .... AIR CONDITIONING
C CALCULATED C.B CATCH BASIN
CL .... CLEAR C/L ....CENTER LINE
ENC... ENCROACHMENT
FIP .... FOUND IRON PIPE
O.H.... OVER HANG
P.B.... PLAT BOOK
P/L ...PROPERTY LINE
UP ... UTILITY POLE
P.0 POINT OF CURVATURE
P.O.BPOINT OF BEUNK:NG
W.MWATER METE
M MEASURED
CONC.. CONCRETE
F.D FOUND
ET8S CONt:REI E EN; Mk ST,!UCTLRE
n.U.I.. OVkRHEAD JTILITY SINE
P.C.C... POINT OF COMPOUND CURVE
P.O.C... POINT OF COMMENCEMENT
9LDG .. 9U11 own
:.H.... CHnRD DISTANCE
D.E DRAINAGE EASEMENT
F.H FIRE HYDRANT
R RADIUS
CERTIFY TO:
Javier Morera And Angel Po r t' is c i a
Joaquin A. Alemany, Esq.
Attorneys' Title Insurance Fund, Inc.
Wachovia Bank, N.A., Its Successors And /Or Assigns
LEGAL DESCRIPTION:
Lot: THE WEST 1/2 OF LOT 4 AND ALL OF LOT
Block: 1
Subdivision: El Portal
According to the Plat thereof as recorded in
Plat Book: 9 Page: 101
Public Records of MIAMI -DADE County, Florida.
ADDRESS:
464 NE 91 STREET
MIAMI SHORES, FL 33198
Encroachments Noted: /%J
LOCATION SKETCH
SCALE: /�-/ . /• ,
NOTES:
A) All Clearances and /or enereochmenh shown
hereon ore of apparent nature. Fence ownership
by visual means. Lego) ownership of fences not
determined.
B) This survey 4 intended for mortgage or refinance purposes
only exclusively for this use by those to whom it is
certified. This survey is not to be used for construction,
permitting, design, or any other use without written con-
sent of Thomas J. Kelly, Inc.
C) Code restriction and title search ore not reflected
on this survey.
D) The flood Information shown hereon does not Imply
that the referenced property will or will not be free
from flooding or damage and does not create liability
on the port of the firm, any officer or employee thereof,
for any damage that results from reliance on said
Information.
E) The lands depicted hereon were surveyed per the
legal description and no claims as to ownership or
matter of title ere mode or Implied.
F) Underground Encroachments, If any, not located.
I hereby certify that the survey represented
hereon meets the minimum technical stan-
dards set forth by th Board of Land Surveyor
in chapter 61917 -6 F ride Administrative Code
pursue chat 2.027 Fla. Statutes.
OS'E"-A, PEREA, P.S. & M. #4858
STATE OF FLORIDA
NOT VALID UNLESS IMPRINTED WITH AN
EMBOSSED SURVEYORS'S SEAL
NOTES:
1. IF SHOWN, BEARING ARE TO AN ASSUMED
MERIDIAN (BY PLAT).
2. IF SHOWN, ELEVATIONS ARE REFERRED N 6. V,D 19Z9
3. THIS IS A BOUNDARY SURVEY.
NGVD ... NATIONAL GEODETIC VERTICAL DATUM
PRC ... POINT OF REVERSE CURVATURE
RAD ... RADIAL
RAN ...RIGHT OF WAY
SEC... SECTION
SCR... SCREENED
3.I.P ..... SET IRON PIPE
SWK...SIDEWALK
U.E
CHLF
UTILITY EASEMENT
CHAIN LINK FENCE
5
NE 91st ST
Sheet 1 ofi9
FLOOD ZONE: X L
_THIS IS A FLOOD
) AZARD ZONE
/THIS I5 NOT A FLOOD
HAZARD ZONE
PANEL NO.:. 93/3
COMMUNITY #: 120652
DATE OF FIRM: 07/17/1995
BASE FLOOD: N/A
FINISH FLOOR: N/A
LOWEST N/A
ADJ GRADE
THOMAS J. KELLY, INC.
L.B. #6486
SURVEYORS - MAPPERS -LAND PLANNERS
8125 SW 120 STREET PINECREST, FLORIDA 33156
(786) 242 -7692 DADE (954) 779 -3288 BRWD
(786) 242 -6494 DADE FAX (954) 779 -3260 BRWD FAX
DATE FIELD WORK
SCALE
, , __. <-- 'SURVEY R NO.
08/29/2006
1" = N ,/,J 06 -4921
U
O
75.0' (R)(M) I FN
F.N�- a o o a o
REM. OF
LOT 4
O
O
M
P.P
•
0
0
SEPQ TANK
ON PL.
CJT 6
ON PL.
O
0
tri
ati
175.00''(R)(M) 9a�°
F� P /� 75.0' (R)(M) : 5' Swx . •
22' PWY
18' ASPHALT PAVEMENT
SHEET 2 OF 2
THOMAS J. KELLY , INC.
L.B # 6486
SURVEYORS— MAPPERS —LAND PLANNERS
8125 SW 120 STREET PINECREST, FLORIDA 33156
(786) 242 -7692 DADE (954) 779 -3288 BRWD
(786) 242 -6494 DADE FAX (954)779 -3260 BRWD FAX
DATE FIELD WORK
08/29/2006
SCALE
1'1=20'
SURVEY NO.
06 -4921
LEGAL:
EL PORTAL PB 9- 1 0 I W 1 /2 LOT 4* LOT 5
8LK I LOT SIZE 75.000 X 1 35 OR
1 9522 -2884 02 2001 I COC
25076 -0 1 9G 25076 -0 1 97 I I O6 1
75.00'
PROVIDE POOL MESH
AROUND POOL
COMPLY WITH SEC. 424.2. 17 PBC.
200' 5 £ 1
0
J
W
z
0
E _EC.
PANEL
4' -711
(\I POOL
EC. EQUIP.
TER
RESIDENCE
ELEV: 1 1 .25'
75.00'
1 '—G"
to
0
0
N S J ST
SITE PLAN
SCALE: 1 " = 20'
ELECTRIC LOAD CALCULATION
PANEL 200 A
ITEM
DEMAND
GENERAL LIGHTING ( 3 WATT /SQJPT.)
5 400 W
SMALL APPLIANCE
3 000 W
LAUNDRY
1500 W
DRYER
5 500 W
RANGE
6000 W
WATER HEATER
2000 W
GARBAGE DISPOSAL
MICROWAVE
1200 W
DISHWASHER
1200 W
TOTAL OF HOUSE LOAD IN WATTS
23 100 W
FIRST 10 KW. AT 100%
10 000 W
REMAINDER AT 40%
13 240 W
A/C N 1 @ 100%
8460 W
A /C#2@ 100%
AICN3 @ I00%
TOTAL DEMANDED WATTAGE
2 1 700 W
TOTAL WATTS DIVIDE BY 240 VOLT = AMP.
90 AMP.
POOL EQUIPMENTS
HEATER
5000 W
POOL PUMP.
2000 W
SPA LIGHT
1 200 W
BLOWER
GOO W
TOTAL WATTS @ 100 %
I 0 200 W
220 -21 FIRST 8 keg AT 100%
8 000
REMAINDER AT 40%
7280
TOTAL WATTS DIVIDED BY WORKS
30 A
POOL TOTAL 100 %
30 A
HOUSE TOTAL DEMANDED
90 A
FINAL TOTAL NEW LOAD
120 A
EXISTING 200 AMP. SERVICE IS OK
9'
1- /2"
VENT
3'
DECK ELEV: 0"
DECK:BRICK ON SAND
8'
c)
1 0' -4"
INLET
SKIMMER
w2 • •
INLET
INLET INLET
w
HANDHOLDS @ 4' MAX.
I -I /2"
VENT
0
SPA ELEV: 1 2"
1 0' -4"
To
300 W
I2 V
INLET LGT I / VACUUM
INLET
MAIN DRAIN
5' -O" DEEP
INLET
■
SWI MOUT
1 8" X 5'
SKIMMER
1-
7
A
8'
23'
32' -G"
a_
WEATHERPROOF GFI
* RECEPTACLE LOCATED I 0 -20
FEET FROM POOL WATER EDGE
31'
1 3'
8'
V-
s
4
G"
qo.
COVERED TERRACE
NOTE: CONTRACTOR SHALL VERIFY ALL SETBACKS
FROM PROPERTY LINES AND STRUCTURES PRIOR TO
EXCAVATION. SHOULD ANY SETBACKS BE LESS THAN
THE MINIMUN REQUIP.EMENTS, EITHER BY OWNER OR
BUILDING OFFICIAL THE ENGINEER SHALL BE NOTIFIED.
RESIDENCE
POOL
EQUIP.
5'
POOL PLAN
SCALE: 1 /4 "= I ' -0"
c
REV.
DATE:O8/ 1 7/07
c5
U
0
0^'
0
N
00
z
d1
0o
U
N
OR 19522 -2884 02 2001
SHEET:
1 OF 2
o/\J AT v CENTERS
HYDROSTATIC
RELIEF VALVE
SET IN W
TYP FOOL SECTION ROCK ED ASHE
NO SCALE
NO SCALE
#3 BARS AT 10" CENTERS
GFI RECEPTACLE
1 0' MIN. 20' MAX,
FROM WATER LINE
STRUCTURAL NOTES:
1 . ALL POOL CONCRETE SHALL DEVELOP A MINIMUM 28 DAY
COMPRESSIVE STRENGTH OF 3000 PSI.
2. ALL REINFORCING STEEL SHALL HAVE A MINIMUM YIELD
STRENGTH OF GO.000 PSI.
3. ALL DECK CONCRETE (WHEN INSTALLED UNDER THESE PLANS)
SHALL HAVE A MINIMUM 25 DAY COMPRESSIVE STRENGTH OF 2500 P51.
4. THE DESIGN OF THIS PROJECT HAS INCORPORATED A
RATIONAL DESIGN APPROACH BASED ON ACCEPTED ENGINEERING
PRINCIPALS,
5. ALL REINFORCING STEEL SPLICES SHALL BE 18" IN LENGTH UNLESS
OTHERWISE INDICATED ON THESE PLANS.
G. ALL REINFORCING STEEL BENDS SHALL BE BY HAND WITHOUT TH
APPLICATION OF HEAT TO THE STEEL.
SOIL NOTE:
BASED ON A VISUAL INSPECTION OF THE SITE,
SOIL CONDITIONS, ROCK AND SAND ARE ADEQUATE
FOR THE DESIGN BEARING CAPACITY OF 2000 PSI.
HOWEVER, IF DURING EXCAVATION, CONDITIONS
OTHER THAN ABOVE ARE ENCOUNTERED, THE
ENGINEER SHALL BE NOTIFIED.
2 # 12 THHN
2P 20 AMP.(PUMP BLOWER)
2# 12 TH H N
1 P. 15 AMF'.(LIHTH)
I # 12 THHN CU. GROUND.
1 P. 15 AMP.(LIGHT)
2F' 20 AMP.(PUMP)
KISER DIAGRA
NOTE; PROVIDE #8 BARE COPPER BOND WIRE FROM LIGHT TO POOL STEEL.WHERE
A CONCRETE DECK IS NOT PROVIDED, PROVIDED A # 8 BARE COPPER BOND
WIRE FROM THE POOL STEEL TO THE EQUIPMENT TO PANEL.
WHERE A CONCRETE SLAB 15 PROVIDED , THE BOND WIRE SHALL BE CONNECTED
FROM THE POOL STEEL TO REINFORCING MESH CONTINUOUS TO THE #5 REINFORC-
ING BAR IN THE PERIMETER SLAB FOOTING. A BOND WIRE SHALL THEN BE CONNECTED
FROM THE PERIMETER STEEL TO THE EQUIPMENT TO THE ELECTRICAL PANEL.
ELECTRICAL NOTES:
I . ALLPOOL ELECTRICAL WORK SHALL BE ACCOMPLISHED IN COMPLIANCE
WITH 2004 FLORIDA RESIDENCE BUILDING CODE.
2.ALL ELECTRICAL GROUNDING AND BONDING MUST BE CONFORM
WITH THE FLORIDA BUILDING CODE.
3. NO OVERHEAD WIRING SHALL BE LOCATED WITHIN 1 0'.O"
OF POOL'S WATER EDGE.
4. SHOULD THE ELECTRICAL RISER DIAGRAM NOT ACCURATELY
DEPICT REQUIRED WORK, A REVISED DRAWING SHALL BE SUB-
MITTED AND APPROVED SHOWING EXPECTED AS BUILT CONFIGURATION
WITH ADDITIONAL SERVICE AND LOAD CALCULATIONS, IF NECESSARY.
5.ALL ELECTRICAL EQUIPMENT NOT SUITABLE FOR EXPOSURE TO THE
ELEMENTS SHALL DE ENCLOSED IN A WEATHERPROOF CONTAINER ALL PUMPS,
HEATERS AND RTELATEDPOOL EQUIPMENT SHOWN ON THESE PLANS ARE
SATISFACTORY FOR EXPOSURE TO THE ELEMENTS.
NOTE:
BASED ON INFORMATION PROVIDED THIS
OFFICE THE EXISTING SERVICE IS ADEQUATE FOR
THE PROPOSED ADDITIONAL POOL EQUIPMENT
LOAD.
G"
WALL SECTION
NO SCALE
INTERLOCKING BRICK
2" SAND BED
ROCK BASE
POOL DECK
POOL SAFETY DEVICES:
AS PER THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, THIS POOL AND /OR SPA MUST BE
PROTECTED ( AT THE OWNER'S EXPENSES) FROM UNAUTHORIZED ACCESS
IN ACCORDANCE WITH ONE OF THE FOLLOWING:
I . A PERIMETER FENCE MUST BE LOCATED AROUND THE POOL UTILIZING A PART
OF THE HOUSE AS A BARRIER THIS METHOD, AT THE OWNER'S EXPENSE, SHALL REQUIRE
COMPLIANCE WHIT 2004 OF THE FLORIDA RESIDENTIAL BUILDING CODE.
ACCESS TROUGH THE BARRIER MUST BE TROUGH SELF CLOSING, SELF
LATCHING GATES COMPLYING WITH THE ABOVE INDICATED ARTICLE.
IF A PART OF THE HOUSE IS TO BE USED AS BARRIER ,ALL DOORS
AND WINDOWS WITH DIRECT ACCESS TO THE POOL SHALL BE EQUIPPED
WITH AN EXIT ALARM COMPLYING WITH 2004 FBCTHAT HAS A MINIMUM
SOUND PRESSURE RATING OF 85 a5 AT 1 0 FEET AND 15 EITHER HARD
WIRED OR THE PLUG -IN TYPE . THE EXIT ALARM SHALL PRODUCE A
CONTINUOUS AUDIBLE WARNING WHEN THE DOOR AND ITS SCREEN ARE
OPENED.
THE ALARM SHALL SOUND IMMEDIATELY AFTER THE DOOR IS
OPENED AND BE CAPABLE OF BEING HEARD THROUGHOUT THE HOUSE
DURING NORMAL HOUSEHOLD ACTIVITIES. THE ALARM SHALL BE
EQUIPPED WHIT A MANUAL MEANS TO TEMPORARILY DEACTIVATE THE
ALARM FOR A SINGLE OPENING. SUCH DEACTIVATION SHALL LAST
NO LONGER THAN 1 5 SECONDS. THE DEACTIVATION SWITCH SHALL BE
LOCATED AT LEAST 54 INCHES ABOVE THE THRESHOLD OF THE DOOR.
2. A SAFETY NET OR COVER SHALL BE INSTALLED COMPLETELY COVERING THE
SURFACE OF THE POOL AND /OR SPA THEREBY PREVENTING ACCESS TO THE
WATER THE NET OR COVER SHALL BE IN COMPLIANCE WITH 2004 FRBC
3. A CHILD SAFETY FENCE (KIDDIES FENCE) A MINIMUM OF 48 INCHES IN HEIGHT SHALL
BE INSTALLED AROUND THE PERIMETER OF THE POOL PREVENTING ACCESS TO THE
WATER FROM ALL DIRECTIONS. THE SAFETY FENCE SHALL BE PERMANENTLY INSTALLED
AT ONE END WHICH CAN ONLY BE REMOVED BY TOOLS.
4. A COMBINATION OF THE PERIMETER FENCE AND CHILD FENCE MAY BE USED TO
PREVENT ACCESS TO THE POOL PROVIDES THE CHILD FENCE IS INSTALLED IN
COMPLIANCE WITH ITEM 3 ABOVE.
SAFETY NOTES:
I .A PERMANENT SAFETY WARNING SIGN MUST BE PROVIDED AT
ALL SWIMMING POOL AND SPA AREAS READILY VISIBLE FROM THE
POOL AREA IN ACCORDANCE WITH 2004 FRBC
2. THE WARNING SIGN, AS PER ITEM I ABOVE, SHALL WARN AGAINST
SHALLOW WATER DIVING, THE PREVENTION OF DROWNING AND SHALL
INCLUDE THE FOLLOWING STATEMENT:
"THERE IS NO SUBSTITUTION FOR ADULT SUPERVISION OF SMALL
CHILDREN. IT IS STRONGLY RECOMMENDED THAT AT LEAST ONE ADULT
RENDERING CHILD SUPERVISION DE TRAINED IN ARTIFICIAL RESPIRATION
AND /OR CARDIOPULMONARY RESUSCITATION(CPU)"
3. ALL DOOR AND WINDOWS WITH DIRECT ACCESS TO THE POOL AREA
MUST BE EQUIPPED WITH AN ALARM WHICH PRODUCES AN AUDIBLE
ALARM WHEN THE DOOR OR ITS SCREEN 15 OPEN.
4. THE POOL AND /OR SPA SHALL NOT BE FILLED WITH WATER UNTIL A
SEPARATE PERMIT HAS BEEN OBTAINED FOR AN APPROVED SAFETY
BARRIER, INCLUDING A SPRING -LOCK SELF - CLOSING GATE.
POOL COPING
1 =111-111 111
1 ITI I E111 -III -I I
WALL
18"
DIGITAL SALT SYSTEM
e0 O\-
,
AIR RELIEF
POOL FILTER WITH 200
SQ.FT. OF SURFACE AREA
CARTRIDGE
ve-°
i \ I 2 5e P-
s ��� �
er. -,,,,,, 4-4)
e� °�� �Poa�
-IN ''''' v.'-',11::;
Viit d -(410"
X71 12 e P
I/
,..-1
4,- .1.1-±,.,,„'
NOTE: BALL VALVES
MAY BE SUBSTITUTED
FOR MULTIPORT VALVES
ISOMETRIC
POOL
RECIRCULATION PUMP
211P, 100 GPM AT GO' TDH
SELF PRIMING
2HP BLOWER
3/4 " x 2"
BULLNOSE TILE NOSING
#3 BARS AT 10" CENTERS
PRICK ON SAND DETAIL
NO SCALE
1 0"
SWI MOUT SECTION
NO SCALE
F'OOL WATER LINE
#3 BARS AT 1 0" C/C
STEPS AND SEAT STEEL
NOT REQUIERED
3/4 " x 2"
HYDROSTATIC
RELIEF NOT REQ'D.
SPA SECTION
NO SCALE
BULLNOSE TILE
PROVIDED SCREEN
MESH AT JOINT
0111%
VENT. DETAI L
NO SCALE
#3 BARS AT 10" C/C
3/4 " x 2"
BULLNOSE TILE NOSING
ON STEPS AND SEAT
#3 BARS AT 1 0" O/C
4 RISERS AT
1 0 I /2" EACH
STEP SECTION
NO SCALE
TOP OF POOL OR SPA
OPING, WHICHERVER HIGHER
SPA POOL
MBING NOTES:
I . ALL POOL EQUIPMENT PIPING SHALL BE SCHEDULE 40,
PVC -PIN, NON - THREADED, NSF APPROVED SUPPORTED CONTINUOSLY
ON GROUND OR ON MAXIMUM 4' -0" CENTERS WITH CLEVIS HANGERS.
2. ALL SUCTION PIPING SHALL BE 2" DIAMETER AND ALL
PRESSURE PIPING 1 1/2" DIAMETER UNLESS OTHERWISE NOTED.
3. POOL WATER DISPOSAL SHALL BE IN ACCORDANCE WITH LOCAL
BUILDING DEPARTMENT REQUIREMENTS.
4. ANTI VORTEX MAINDRAINS SHALL HAVE ITS PLATE SECURELY FASTENED
WITH TAMPERPROOF SCREWS.
5. POOL VACUUM SHALL HAVE SPRING LOADED CAP IN ACCORDANCE
WITH THE FLORIDA BUILDING CODE.
G. ALL PIPING SHALL BE INSTALLED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE - PLUMBING SECTION 309 AS IT PERTAINS
TO BOUY ANCY.
7. THE WATER VELOCITY THOUGH ALL SUCTION PIPING SHALL BE LESS
THAN 8 FEET PER SECOND.
5. THE WATER VELOCITY THROUGHT ALL PRESSURE PIPING SHALL BE LESS
THAN I 0 FEET PER SECOND.
9. ALL PIPING SHALL BE SUITABLE FOR EXPOSURE TO ULTRA VIOLET
RADIATION AND NORMAL OPERATING TEMPERATURES.
WIRE # 8 COOPER
TO POOL EQUIPMENT
POOL STEEL
NOTE: PROVIDE
CONTINUOS SINGLE # 8 COOPER
BONDED IN FOUR POINT(3GO ^ )
AROUND POOL * SPA
I " NON METALLIC CONDUIT
TO JUNCTION BOX
NOTE: BOND WIRE TO BE SECURED
TO STEEL 4 GRID WITH APPROVED CLAMP.
TO BE ENCASED IN DECK SLAB
OR CONCRETE BOX PROVIDING
MIN. 3" OF COVER AROUND CLAMP
POOL DATA:
SWIMMING POOL
45
SURFACE AREA (SQ.FT.)
393
101 2
VOLUME (GALLONS)
I 1 970
1 . I G
TURNOVER (HOURS)
I .9
28
PERIMETER (FEET)
92
LESS 2'.O" HYDROST VALVE
DECK AREA ( SQ.FT)
745
HYDROSTATIC UFLItT
ELEV. TOP OF POOL WALL
9.50'
DEPTH OF POOL
5.0'
ELEV, TOP OF MAINDRAIN
4.50'
FLOOD CRITERIA
8.0'
ELEV. TOP OF MAINDRAIN
4.50'
POOL IN FLOOD CRITERIA
3.50'
LESS 2'.O" HYDROST VALVE
I .50
SLAB THICKNESS REQUIRED
G"
POOL BOND $
UNDERWATER LIGHT DETAIL
TEE
SAME SIZE
AS PUMP
SUCTION
3' -O" MINIMUN
NO SCALE
TEX
IN COVERS
NOTE: IF THE F'OOL IN FLOOD CRITERIA IS LESS THAN
G.7 FEET THEN THE FLOOR SLAB SHALL TAPER FROM
G" AT THE SHALLOW END TO THAT INDICATED ABOVE
AS SLAB THICKNESS REQUIRED.
\.>' I I /2" HYDROSTATIC RELIEF
TUBE . ONLY ONE REQUIRED
MAN DRAI N DETAI L
NO SCALE
00
z
0
a
0
0
W
(9
SHORES FL33138-
WATER LEVEL
CERAMIC TILE
THROAT
F'OOL WALL
WEIR
ADJUSTABLE LID
NCTRETE
BASKET
(MIN.75 SQ.IN.)
SUCTION LINE
SKIMMER DETAIL
NO SCALE
REV.
DATE:05 /20/07
O
U
0000
00
N
C4
N
1
SHEET:
1 OF 2
300 W
TRANSFORMER
#3 BARS AT 10" CENTERS
NO SCALE
HYDROSTATIC
RELIEF VALVE
SET TYP POOL SECTION ROCK EADSHE
NO SCALE
HEAT PUMP
O
3 # 8 3/4" C
2P 40 A
\ 40ASW
1
#3 BARS AT 10" CENTERS
2 # 1 2
I # I2 CU.
GROUND.
GPI RECEPTACLE
1 0' MIN. 20' MAX.
FROM WATER LINE
EXIST.
PANEL
METER COMBO
200 A
2 # 12
I # 12 CU.
GROUND.
I P. 15 AMP.(LIGHT)
2P 20 AMP.(PUMP)
100 W
TRANSFORMER
O
2# I2THHN
2P 20 AMP.(PUMP * BLOWER)
2# 1 2 THHN
1 P. 15 AMP.(LIHTH)
I # 12 THHN CU. GROUND.
2 # 12 THHN
I # 12 THHN CU. GROUND.
2 HP PUMP
230 V.
75 W
12 V SPA LIGHT
300 W
12 V POOL LIGHT
STRUCTURAL NOTES:
DIGITAL SALT SYSTEM
I . ALL POOL CONCRETE SHALL DEVELOP A MINIMUM 28 DAY
COMPRESSIVE STRENGTH OF 3000 PSI.
2. ALL REINFORCING STEEL SHALL HAVE A MINIMUM YIELD
STRENGTH OF 60.000 PSI.
3. ALL DECK CONCRETE (WHEN INSTALLED UNDER THESE PLANS)
SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2500 PSI.
4. THE DESIGN OF THIS PROJECT HAS INCORPORATED A
RATIONAL DESIGN APPROACH BASED ON ACCEPTED ENGINEERING
PRI N CI PALS.
5. ALL REINFORCING STEEL SPLICES SHALL BE 1 8" IN LENGTH UNLESS
OTHERWISE INDICATED ON THESE PLANS.
G. ALL REINFORCING STEEL BENDS SHALL BE BY HAND WITHOUT THE
APPLICATION OF HEAT TO THE STEEL.
HEAT PUMP.
41)'
)��s
JSOIL NOTE:
BASED ON A VISUAL INSPECTION OF THE SITE,
SOIL CONDITIONS, ROCK AND SAND ARE ADEQUATE
FOR THE DESIGN BEARING CAPACITY OF 2000 PSI.
HOWEVER, IF DURING EXCAVATION, CONDITIONS
OTHER THAN ABOVE ARE ENCOUNTERED, THE
ENGINEER SHALL BE NOTIFIED.
2" FROM
POWER COMPANY
TRANSFER PAD.
RISER DIAGRAM
NOTE; PROVIDE #8 BARE COPPER BOND WIRE FROM LIGHT TO POOL STEEL.WHERE
A CONCRETE DECK IS NOT PROVIDED, PROVIDED A # 5 BARE COPPER BOND
WIRE FROM THE POOL STEEL TO THE EQUIPMENT TO PANEL.
WHERE A CONCRETE SLAB IS PROVIDED , THE BOND WIRE SHALL BE CONNECTED
FROM THE POOL STEEL TO REINFORCING MESH CONTINUOUS TO THE #5 REINFORC-
ING BAR IN THE PERIMETER SLAB FOOTING. A BOND WIRE SHALL THEN BE CONNECTED
FROM THE PERIMETER STEEL TO THE EQUIPMENT TO THE ELECTRICAL PANEL.
ELECTRICAL NOTES:
1 . ALLPOOL ELECTRICAL WORK SHALL BE ACCOMPLISHED IN COMPLIANCE
WITH 2004 FLORIDA RESIDENCE BUILDING CODE.
2.ALL ELECTRICAL GROUNDING AND BONDING MUST BE CONFORM
WITH THE FLORIDA BUILDING CODE.
3. NO OVERHEAD WIRING SHALL BE LOCATED WITHIN 1 0'.0"
OF POOL'S WATER Ew�GE.
4. SHOULD THE ELECTRICAL RISER DIAGRAM NOT ACCURATEL`d
DEPICT REQUIRED WORK, A REVISED DRAWING SHALL BE SUB-
MITTED AND APPROVED SHOWING EXPECTED AS BUILT CONFIGURATION
WITH ADDITIONAL SERVICE AND LOAD CALCULATIONS, IF NECESSARY.
5.ALL' ELECTRICAL EQUIPMENT NOT SUITABLE FOR EXPOSURE TO THE
ELEMENTS SHALL BE ENCLOSED IN A WEATHERPROOF CONTAINER ALL PUMPS,
HEATERS AND RTELATEDPOOL EQUIPMENT SHOWN ON THESE PLANS ARE
SATISFACTORY FOR EXPOSURE TO THE ELEMENTS.
NOTE:
BASED ON INFORMATION PROVIDED THIS
OFFICE THE EXISTING SERVICE IS ADEQUATE FOR
THE PROPOSED ADDITIONAL POOL EQUIPMENT
LOAD.
6"
WALL SECTION
INTERLOCKING BRICK
2" SAND BED
ROCK BASE
POOL DECK
POOL SAFETY DEVICES:
AS PER THE 2004 FLORIDA RESIDENTIAL BUILDING CODE, THIS POOL AND /OR SPA MUST BE
PROTECTED ( AT THE OWNER'S EXPENSES) FROM UNAUTHORIZED ACCESS
IN ACCORDANCE WITH ONE OF THE FOLLOWING:
I . A PERIMETER FENCE MUST BE LOCATED AROUND THE POOL UTILIZING A PART
OF THE HOUSE AS A BARRIER THIS METHOD, AT THE OWNER'S EXPENSE, SHALL REQUIRE
COMPLIANCE WHIT 2004 OF THE FLORIDA RESIDENTIAL BUILDING CODE.
ACCESS TROUGH THE BARRIER MUST BE TROUGH SELF CLOSING, SELF
LATCHING GATES COMPLYING WITH THE ABOVE INDICATED ARTICLE.
IF A PART OF THE HOUSE 15 TO BE USED AS BARRIER ,ALL DOORS
AND WINDOWS WITH DIRECT ACCESS TO THE POOL SHALL BE EQUIPPED
WITH AN EXIT ALARM COMPLYING WITH 2004 FBCTHAT HAS A MINIMUM
SOUND PRESSURE RATING OF 85 dB AT 1 0 FEET AND 15 EITHER HARD
WIRED OR THE PLUG -IN TYPE . THE EXIT ALARM SHALL PRODUCE A
CONTINUOUS AUDIBLE WARNING WHEN THE DOOR AND ITS SCREEN ARE
OPENED.
THE ALARM SHALL SOUND IMMEDIATELY AFTER THE DOOR IS
OPENED AND BE CAPABLE OF BEING HEARD THROUGHOUT THE HOUSE
DURING NORMAL HOUSEHOLD ACTIVITIES. THE ALARM SHALL BE
EQUIPPED WHIT A MANUAL MEANS TO TEMPORARILY DEACTIVATE THE
ALARM FOR A SINGLE OPENING, SUCH DEACTIVATION SHALL LAST
NO LONGER THAN 15 SECONDS. THE DEACTIVATION SWITCH SHALL BE
LOCATED AT LEAST 54 INCHES ABOVE THE THRESHOLD OF THE DOOR.
2. A SAFETY NET OR COVER SHALL BE INSTALLED COMPLETELY COVERING THE
SURFACE OF THE POOL AND /OR SPA THEREBY PREVENTING ACCESS TO THE
WATER THE NET OR COVER SHALL BE IN COMPLIANCE WITH 2004 FRBC
3. A CHILD SAFETY FENCE (KIDDIES FENCE) A MINIMUM OF 48 INCHES IN HEIGHT SHALL
BE INSTALLED AROUND THE PERIMETER OF THE POOL PREVENTING ACCESS TO THE
WATER FROM ALL DIRECTIONS. THE SAFETY FENCE SHALL BE PERMANENTLY INSTALLED
AT ONE END WHICH CAN ONLY BE REMOVED BY TOOLS.
4. A COMBINATION OF THE PERIMETER FENCE AND CHILD FENCE MAY BE USED TO
PREVENT ACCESS TO THE POOL PROVIDES THE CHILD FENCE IS INSTALLED IN
COMPLIANCE WITH ITEM 3 ABOVE.
SAFL I Y NOTES:
I .A PERMANENT SAFETY WARNING SIGN MUST BE PROVIDED AT
ALL SWIMMING POOL AND SPA AREAS READILY VISIBLE FROM THE
POOL AREA IN ACCORDANCE WITH 2004 FRBC
2. THE WARNING SIGN, AS PER ITEM 1 ABOVE, SHALL WARN AGAINST
SHALLOW WATER DIVING, THE PREVENTION OF DROWNING AND SHALL
INCLUDE THE FOLLOWING STATEMENT:
"THERE IS NO SUBSTITUTION FOR ADULT SUPERVISION OF SMALL
CHILDREN. IT IS STRONGLY RECOMMENDED THAT AT LEAST ONE ADULT
RENDERING CHILD SUPERVISION BE TRAINED iN ARTIFICIAL RESPIRATION
AND /OR CARDIOPULMONARY RESUSCITATION(CPU)"
3. ALL DOOR AND WINDOWS WITH DIRECT ACCESS TO THE POOL AREA
MUST BE EQUIPPED WITH AN ALARM WHICH PRODUCES AN AUDIBLE
ALARM WHEN THE DOOR OR ITS SCREEN IS OPEN.
4. THE POOL AND /OR SPA SHALL NOT BE FILLED WITH WATER UNTIL A
SEPARATE PERMIT HAS BEEN OBTAINED FOR AN APPROVED SAFETY
BARRIER, INCLUDING A SPRING -LOCK SELF - CLOSING GATE.
NO SCALE
POOL COPING
WALL
7-I g1 T IT 1 I Ir;r�
-III III 111=111
:l 11 -11 I 1 111 11
18"
j*. *
i•p t 4.414,1,7- 4,
P�Q __ �PN,0 .
OV Se P
12
AIR RELIEF
POOL FILTER WITH 200
SQ.FT. OF SURFACE AREA
CARTRI DGE
NOTE: BALL VALVES
MAY BE SUBSTITUTED
FOR MULTIPORT VALVES
1>-\‘?-- V
3/4 "x 2"
BULLNOSE TILE NOSING
#3 BARS AT 10" CENTERS
BRICK ON SAND DETAIL
I O"
NO SCALE
1 0"
N
6" CERAMICS
SWI MOUT SECTION
NO SCALE
1 0"
ISO M ET RI C
' r
POOL
RECIRCULATION PUMP
2HP, 100 GPM. AT 60' TDH
SELF PRIMING
i
PLUMBING NOTES:
1 . ALL POOL EQUIPMENT PIPING SHALL BE SCHEDULE 40,
PVC -PIN, NON - THREADED, NSF APPROVED SUPPORTED CONTINUOSLY
ON GROUND OR ON MAXIIVCUIS/L41 O" CENTERS WITH CLEVIS HANGERS.
2. ALL SUCTION PIPING SHALL BE 2" DIAMETER AND ALL
PRESSURE` PIPING I - I /.2-1- DIAMETER UNLESS OTHERWISE NOTED.
3. POOL WATER DISPOSAL SHALL BE IN ACCORDANCE WITH LOCAL
BUILDING DEPARTMENT REQLAREMENTS.
4. ANTI VORTEX MAINDRAINNS SHALL HAVE ITS PLATE SECURELY FASTENED
WITH' TAM P €RPROOF ,SCREWS... .
5. POOL VACUUM SHALL HAVE SPRING LOADED CAP IN ACCORDANCE
WITH THE FLORIDA DUI LDI,NGt CODE.
G. ALL PIPING SHALL 13E`S�NSTALLED IN ACCORDANCE WITH THE
FLORIDA.BU.IL_DING CODE- PLUMBING SECTION 309 AS IT PERTAINS
TO BOUY ANCY. _.... _.. ......_....
7. THE WATER VELOCITY THOUGH ALL SUCTION PIPING SHALL BE LESS
THAN 8 FEET PER SECOND OJ£
8. THE WATER VELOCITY TI-1R000HT ALL PRESSURE PIPING SHALL BE LESS
THP N I O FEET PER SECOND. - -. I
J a J,I ALL' PIPI IVG- 1ALL IMF, SUITABLE FOR EXPOSURE TO ULTRA VIOLET
- RADIATION AND NORMAL OPERATING TEMPERATURES.
21-1P BLOWER
WIRE # 8 COOPER
TO POOL EQUIPMENT
POOL STEEL
0
w
IL]
0
18" MIN
DECK
NOTE: PROVIDE
CONTINUOS SINGLE # 8 COOPER
BONDED IN FOUR POINT(3G0 ^ )
AROUND POOL * SPA
I " NON METALLIC CONDUIT
TO JUNCTION BOX
DATE:
POOL WATER LINE
#3 BARS AT 10" C/C
NOTE: BOND WIRE TO BE SECURED
TO STEEL * GRID WITH APPROVED CLAMP.
TO BE ENCASED IN DECK SLAB
OR CONCRETE BOX PROVIDING
MIN. 3" OF COVER AROUND CLAMP
3/4 " x 2"
BULLNOSE TILE NOSING
ON STEPS AND SEAT
POOL BOND $
UNDERWATER LIGHT DETAIL
NO SCALE
3' -O" MINIMUN
#3 BARS AT 10" C/C
STEPS AND SEAT STEEL
NOT REQUIERED
HYDROSTATIC
RELIEF NOT REQ'D.
SPA SECTION
NO SCALE
1 ' -8„
3/4 " x 2" -1 ■■
DULLNOSE T1 LE -
PROVIDED SCREEN
MESH AT JOINT
Ii1%
VENT. DETAIL
#3 BARS AT 10" O/C
4 RISERS AT
1 0 I /2" EACH
STEP SECTION
NO SCALE
TOP OF POOL OR SPA
OPING, WHICHERVER HIGHER
NOSCALE
NO SCALE
SPA POOL
POOL DATA:
SWIMMING POOL
45
SURFACE AREA (SQ.FT.)
393
I 0 I 2
VOLUME (GALLONS)
I 1 970
I . 1 6
TURNOVER (HOURS)
I .9
28
PERIMETER (FEET)
92
LESS 2'.O" HYDROST VALVE
DECK AREA ( SQ.FT)
745
HYDROSTATIC UPLIFT
ELEV. TOP OF POOL WALL
9.50'
DEPTH OF POOL
5.01
ELEV. TOP OF MAINDRAIN
4.50'
FLOOD CRITERIA
5.0'
ELEV. TOP OF MAINDRAIN
4.50'
POOL IN FLOOD CRITERIA
3.50'
LESS 2'.O" HYDROST VALVE
1 .50
SLAB THICKNESS REQUIRED
G"
NOTE: IF THE POOL IN FLOOD CRITERIA IS LESS THAN
G.7 FEET THEN THE FLOOR SLAB SHALL TAPER FROM
G" AT THE SHALLOW END TO THAT INDICATED ABOVE
AS SLAB THICKNESS REQUIRED.
TEE
SAME SIZE
AS PUMP
SUCTION
•
12
I I /2" HYDROSTATIC RELIEF
TUBE . ONLY ONE REQUIRED
MAN DRAIN DETAIL
WATER LEVEL
CERAMIC TILE
THROAT
POOL WALL
WEIR
NO SCALE
ADJUSTABLE LID
NCTRETE
BASKET
(MIN.75 SQ.IN.)
SUCTION LINE
SKIMMER DETAIL
NO SCALE
0
U
0
O
N
N
0
00
00
N
SHEET:
1 OF 2
CI Y
UUL J
PY
RECEIVE
AUG 0 2 2C0
BY I i►.
PERMIT #
MIAMI SHORES VILLAGE
APPROVED
ZONING
STRUCTURAL
ELECTRICAL
PLUMBING
MECHANICAL
BLDG.
SUBJECT TO COMPLIANCE WITH ALL FEDERAL
STATE AND COUNTY RULES AND REGULATIONS
1