ROOFINGApplication is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build-
ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
Date / ✓ 19.1
Owner's Name and Address Ate�fluit �' /1 _ e 1 meivo No._.f W Street. W / --3 -ST -
Registered Registered Architect and /or Engineer
Name and address of licensed contractor
Location and legal description of lot to be built on:
Lot Block Subdivision
Street and Number where work is to be done
State work to be done and purpose of building (by floors) N EWF
T► Lt cOJ t T- QGENI)
and for no other purpose.
New Building Remodeling Addition Repairs No. of Stories 1
To be constructed of Kind of foundation Roof Covering afiftyr SP/AVE J' /l
Estimated Total cost of improvements $ �,.. 4.3 1 3 1, do Amount of Permit $
Zone cubage required .Plan Cubage
Distance to next nearest building Size of Building Lot
Maximum live load to be borne by each floor
I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may
be sent to
The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer
of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent SuPplement,
and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him
in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice
or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, n work . - performed under this
permit, as are licensed by Miami Shores Village.
Remarks (Signed)
STATE OF FLORIDA,
COUNTY OF DADE. ss.
Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap-
peared
to me well known,
and who, being by me first duly sworn, upon oath deposes and says that he is the
of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts
therein by him stated are true.
Permit No ICI 2 ` �
Disapproved
(Signed)
(A7t
APPLICATION FOR mUILDONS PE MOT
Date___
Building Inspector
LANNING BOARD
Chairman
Member
Member _
Council Approved Date
BUILDING iNSP -CT C,.: iDaPARTIVlEN T
Citicev7lf �'e oeFfA r Co, Ac-- Sol NW
l3, 00
Read, Sworn to and Subscribed before me.
Notary Public, State of Florida
My Commission Expires
DATE
�dl IVF 03 ST
3 tri l -3e 1- 90 ceroir SH /NEtf
Member
Member
Member
Disapproved Date
NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from
the Planning Board.
A re inspection fee of $1.00 will be charged when such re inspection is made necessary by improper notice for inspection or faulty
materials and /or workmanship.
Date
Legal Description
m /s. Tbe1p e c4
Owner's Address lots / U . E • 9 3 Si
Contractin Co. 'R- N . ? a\ Yv\ e r R iivr1
Owner/Lessee / Tenant
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Job Address 1015 / Y o • 93 S) Tax Folio
Qualifier obe44 Id. Toil me v
State # Municipal #
Architect/Engineer
Bonding Company
Mortgagor Address
Permit Type (circle one): BUILDING ELECTRICAL
WORK DESCRIP'T'ION / 12 Gtr r e/274
sLc 4e hd- �a� . r.NS +-0,1\
Square Ft. /
\\\\ 111
Si i . e 'Its pP' 831 ��•�, Wine--
N s to flr : r.; , �
p ublic utr;.'� O \�
!/C STP 0 ', ,\
ado President
d
FEES: PERMIT 3 ad RADON
Date
/14f-* President /14f-* ?-'91) APPROVED: Ddte
Zoning Buildin
Mechanical Plumbing
Historically Designated: Yes No
Competency #
Address
Address
PLUMBING MECHANICA ROC; oC; on e x /157 U P a o
hleW Y�y S rIASI- WeS4-i t e
J � �" Cv �. EZ Estimated Cost (value) 2 / / b 0
Master Permit # 967
Phone 305 - 75- 5 40 /5
Address / (9-1 /V . (.J WU )
Electrical
ROOFING
Ins. Co.
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.)
Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I
certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable
laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated.
PAVING FENCE SIGN
NOTARY BOND 30 ✓
TOTAL DUE 6/......?
O .
Engineering
MAY -24 -00 09:23 PM R.N.PALMER.ROOFING
A RECORDED
PERMI1 NO.
STATE OF FLORIDA:
COUNTY OF DADE:
THE UJ' DERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with
Chapter 713, Florida Statutes, the following information is provided in This Notice of Commencement
1. Legal description of properly and street Address.
2. Description of improvement: _ —
3. Owner(s) name and address: _ �, ,Q ''5 /, �q� ``
� � L . Q� G e c.1 --
IntereSt in properly. _
Name and address of fee simple tilleliolder. _
.NOTICE OF COMMENCEMENT
COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTI04
TAX FULIONO
4 . Contractor's name and address Grri
Wi
5. Surety,(Payment bond required by owner horn contractor, it any)
Name and address:
Amount of bond $
6. Lender's name and address,
7. Persons within the State of Florida designated by Owner upon whore notices or other documents may be served as provided„
by Seclidn713.13(1)(a(7.. Florida Statutes,
Narne and address:
8.1n addition to (rimsell, Owner designates the tollowing person(s) to receive a copy of the Lienor's Notice as provided in
Section 713.13(1)(b), Florida Statutes
Name arld address:
9. Expiration date of this Notice of Commencement. (the expiration dale is 1 year from the date of recording unless a
different dale Is specified)
/ -- — �� 01111f14
'l r 14)
ca ' � • M- lss'k ?
s,pnaw,o r Owner • CJ 1 ?
Prins Owneis Name • S
Sworn lo and ubscrl
s bed berore me This lZ day a fi 0 922 2
r. `Y.iF. CYA _ d\
•.:.. A1E OF F LOFT:A, COUNTY OF DADE
r N E PLCYCErollFY 1n11 rnss.lr pprn
Opv,nal /tied ,r; t? 'tree on . - � d l oy Cr
no 20 !Li [..___
wl rNE 5S my hand a d Gtf,e,ar
HARVEY r UVIN 111 crCucuu Cousq'r.num
gy - ✓��
-- D.C.
-tr
6527800
00R243!90 OQO MAY /411V i37
Prepared by• _ �2
Address
P. 01
9
5104 API'ENDIX "F"
APPENDIX "F "REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS
As it pertains to this Appendix "F ", it is the responsibility of the roofing contractor to provide the owner
with the required roofing permit, to provide the owner with this appendix and to explain to the owner the
content of this form. The provisions of Chapter 34 of the South Florida Building Code (SFBC) govern
the minimum requirements and standards of the industry for roofing system installations. Additionally,
the following items should be addressed as part of the agreement between the owner and the contractor.
The owner's initial in the adjacent box indicates that the item has been explained.
? Al ke thetics- Workmanship: The workmanship provisions of Chapter 34 are for the purpose of
providing the roofing system meets the wind resistance and water intrusion performance standards.
Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic
issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as
part of thee agreement between the owner and the contractor.
r u
�,t) \ l .Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be
renailedin accordance with the current provisions of Chapter 29 of the SFBC. (The roof deck is usually
concealed prior to removing the existing roof system)
/14.41)C 3. Common Roofs: Common roofs are those which have no visible delineation between
neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing
contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed.
9.1.Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking
can be viewed from below. The owner may wish to maintain the architectural appearance, therefore,
roofing nail penetrations of the underside of the decking may not be acceptable. The SFBC provides the
option of maintaining this appearance.
040 5Ponding Water: The current roof system and/or deck of the building may not drain well and
may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of
structural distress and may require the review of a professional structural engineer. Ponding may shorten
the life expectancy and performance of the new roofing system. Ponding conditions may not be evident
until the original roofing system is removed. Ponding conditions should be corrected.
{/ << L 6. Overflow Scuppers (wall outlets): It is required that rainwater flow off so that the roof is not
overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this
discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow
scuppers �� with Chapter 23 of the SFBC.
►�LG�_�?�_Ventilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not
be reduced. It may be beneficial to consider additional venting which can result in extending the service
life of the roof.
Owner's /Agent's Signatu Dat
Signature
J'f�� $01)
Contractor's Name: R. N. P& me y ?CbA'11/5 Job Address: / a /5 A 1.1 3 5/.
❑ (Low Slope Application)
❑ (Asphalt/Fiberglass Shingles)
❑ New Roof
ROOF CATEGORY
❑ (Nail -On Tile) ❑ (Mortar- Adhesive Set Tile)
❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other)
ROOF TYPE
L'Re roofing ❑ Recovering ❑ Repair ❑ Maintenance
Flat Roof Area (ft 0 Sloped Roof Area (ft 5 O Total (ft Master Permit No.
Exposure category (per ASCE 7 -88): (' Building Classification category (per ASCE 7 -88 table 1):
Ft.
A
V
Ft.
A
V
Deck type:
ATTACHMENT
Fastener Type:
Field:
SPACING
Perimeter: Corner:
DETAIL 1 & 2
ROOF HEIGHT AND SYSTEM DETAILS
(Draw details as needed)
ROOF PLAN
=_3`
1 ,4
123.01 -78 9/96
Appendix "E"
UNIFORM ROOFING PERMIT APPLICATION
PROCESS No.
Page -1
Appendix "E"
UNIFORM ROOFING PERMIT APPLICATION
PROCESS No.
Ridge Ventilation?
Deck type:
MEAN HEIGHT )
WO
z Underlayment:
2»
Insul
D E T A I L 3
SLOPED SYSTEM DESCRIPTION
COQ e # 3D 4s7A/
tion:
12"
ROOF SLOPE
Fastener type & spacing:
Cap Sheet:
Ro
/Y Rine 4, /./
On? # .2.6 sla '-
o C overin g :
Drip edge:
, Rte S wank,
3" X 3 ' eAUe
ATTACHMENTS REQUIRED
1) Fire Directory Listing Page
2) Dade County Product Control
Notice of Acceptance -Cover Sheet
a) Specific System Description
b) Specific System Limitation
c) General Limitations
d) Applicable Detail Drawings
3) Municipal Permit Application
4) Other Component Approvals
TILE CALCULATIONS
(Pmaxl: 7°_' X ? (Aerodynamic Multiplier):O.)S(q) - M 7. (/ 3 = M + CA: / 18 . 9
( Pmax2: /6 . / x a, (Aerodynamic Multiplier): 0 . a Fl9 �V
) - M 7. 3 = M . )O PCA: / /
X a, (Aerodynamic Multiplier): 0, ) - M 7. y 3= M pg. c /
7 3 9 5. ?
0 avbfl 0. 02119
9 9
7 . �3
7. 7
7-
8
MIAMI-OADE
PERI
OLDCASTLE WESTILE, INC. ACCEPTANCE No.: 99- 1102.01
PRODUCT CONTROL NOTICE OF ACCEPTANCE
Oldcastle Westile, Inc.
1900 NW 21st Avenue
Ft.Lauderdale
The expense of such testing will be incurred by the manufacturer.
Acceptance No.:99- 1102.01 (Revises No.: 99- 0603.01)
Expires:12 /16/2002
Approved: 12 /16/1999
1 of 8
}II, \III -DARE COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
BUILDING CODE COMPLIANCE OFFICE
METRO -DADS FLAGLER BUILDING
1.10 WEST FLAGLER STREET. SUITE 1603
MIA`II, FLORIDA 33130-1563
(305) 375 - 2901 FAX (305) 375-2908
CONTRACTOR LICENSING SECTION
(305) 375 -2527 FAX (305) 375.2558
FL 33311 CONTRACTOR ENFORCEMENT SECTION
(305) 375 -2966 FAX (305) 375.2908
PRODUCT CONTROL DIVISION
Your application for Product Approval of: (305) 375 -2902 FAX (305) 372.6339
Fla! Shake and Slate
under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types of
Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade
County Building Code Compliance Office (BCCO) under the conditions specified herein.
This approval shall not be valid after the expiration date stated below. BCCO reserves the right to secure this
product or material at anytime from a jobsite or manufacturer's plant for quality control testing.
If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend
the use of such product or material immediately. BCCO reserves the right to revoke this approval, if it is
determined BCCO that this product or material fails to meet the requirements of the South Florida Building
Code.
Raul Rodriguez
Chief Product Control Division
THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL
CONDITIONS
BUILDING CODE & PRODUCT REVIEW COMMITTEE
This application for Product Approval has been reviewed by the BCCO and approved by the Building Code
and Product Review Committee to be used in Dade County, Florida under the conditions set forth above.
e4avz,A.
.ran csi Quintana, R.A.
Director
Miami -Dade County
Building Code Compliance Of[ic
OLDCASTLE WESTILE, INC.
ACCEPTANCE No.: 99- 1102.01
APPROVED: December 16, 1999
EXPIRES: December 16, 2002
NOTICE OF ACCEPTANCE: STANDARD CONDITIONS
1. SCOPE
This revises roofing system using "Oldcastle Westile Flat Shake and Slate ", as
manufactured Oldcastle Westile, Inc. Tile described in Section 2 of this Notice of
Acceptance, designed to comply with the South Florida Building Code, 1994 Edition for
Miami -Dade County. For the locations where the pressure requirements, as determined by
SFBC Chapter 23, do not exceed the design pressure values obtain by calculations in
compliance with RAS 127 using the values listed in section 4 herein. The attachment
calculations shall be done as a moment based system.
Category: Prepared Roofing
Sub Category: Flat Profile Tile
2. PRODUCT DESCRIPTION
Manufactured by
Applicant
Oldcastle Westile Flat
Shake and Slate Tile
Trim Pieces
Product
#30 Felt
Test
Dimensions Specifications
1= 16'/ :"
w= 13"
5 /," thick
1= varies
w = varies
varying thickness
2.1Components or products manufactured by others
Dimensions
N/A
Test
Specifications
ASTM D 226
type 11
#43 Coated Base N/A ASTM D 2626
Sheet
Mineral Surface Cap N/A
Sheet
ASTM D 249
Product
Description
PA 112 Flat, interlocking, high pressure extruded
concrete shake and slate roof tile equipped with
two nail holes. For direct deck or battened nail -
on, mortar or adhesive set applications.
PA 112 Accessory trite, concrete roof pieces for use at
hips, rakes, ridges and valley terminations.
Manufactured for each tile profile.
Product
Description
Saturated organic felt to be
used as a nailed anchor sheet.
Manufacturer
generic
Saturated and coated organic generic
base sheet for single or double
ply underlayment.
Mineral surfaced asphalt roll generic
roofing for use as a top ply in
a double ply under) „ t ent
system.
F oaga, RRC
Roofing Product Control Examiner
OLDCASTLE WESTILE, INC.
Product
Rainproof 11
Ice and Water Shield
Wood Battens
Tile Nails
Tile Screws
Roof Tile Mortar
( "TileTiteTM ")
ACCEPTANCE No. : 99-1102.01
APPROVED: December 16, 1999
EXPIRES: December 16, 2002
NOTICE OF ACCEPTANCE: STANDARD CONDITIONS
Dimensions
30" x 75' roll
36" x 75' roll
or
60" x 75' roll
36" x 75' roll
vertical
min. I "x4"
horizontal
min. 1" x 4" for
use with vertical
battens or
min. I "x2 "for
use alone
Min. l0d x 3"
148 x 2 '/:" long
0.335" head dia.
0.131" shank dia.
0. 175" sctrew
thread diameter
Hurricane Clip & Clips
Fasteners min.' /:" width
min. 0.060" thick
Clip Fasteners
min. 8d x 11/4"
N/A
Test
Specifications
PA 104
PA 103
Wood Preservers Salt pressure treated or decay
Institute LP - 2 resistant lumber battens
PA 114
Appendix E
PA 114
Appendix E
PA 114
Appendix E
PA 123
3
Product
Description
Single ply, nail -on
underlayment with 2" self -
adhering top edge.
Self - adhering underlayment
for use as a top ply in a two
ply underlayment system with
Approved #30 or 1143 as the
base layer.
Corrosion resistant, screw or
smooth shank nail
Corrosion resistand coated,
square drive, galvanized,
coarse thread wood screw
Corrosion resistant bronze,
aluminum, stainless steel,
galvanized steel or plastic
attachment clips for
supplemental tile attachment.
Clips are installed with
corrosion resistant roofing
nails compatible with the clip.
A hurricane clip is required on
all nail -on cave tiles.
Prepared mortar mix designed
for mortar set roof tile
applications.
Manufacturer
Protect -O -Wrap, Inc.
with current NOA
W.R. Grace Co.
with current NOA
generic
generic
generic
generic
Bermuda Roof
Company, Inc.
with current NOA
Fracik Zuloaga, RRC
Roofing Product Control Examiner
OLDCASTLE WESTILE, INC.
Product
Roof Tile Mortar
( "Quikrete® Roof
Tile Mortar 111140 ")
Roof Tile Mortar N/A PA 123
( "BONSAL® Roof
Tile Mortar Mix ")
Tile -Bond Factory premixed See PCA
canisters
Roof Tile Adhesive N/A See NOA
( "Polypro® AH 160 ")
3. LIMITATIONS
ACCEPTANCE No.: 99- 1102.01
APPROVED: December 16, 1999
EXPIRES: December 16, 2002
NOTICE OF ACCEPTANCE: STANDARD CONDITIONS
Dimensions
N/A
Test
Specifications
PA 123
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be
performed in accordance with RAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory
to perform quarterly test in accordance with PA 112, appendix 'A'. Such testing
shall be submitted to the Building Code Compliance Office for review.
3.4 Minimum underlayments shall be in compliance with the applicable Roofing
Applications Standards listed section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to
the roof slope unless stated otherwise by the underlayment material manufacturers
published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall
be in compliance with chapter 29 of the SFBC.
4. INSTALLATION
4.1.1 "Flat Shake and Slate" and its components shall be installed in strict compliance
with Miami Ddde County Roofing Application Stand RAS 118, RAS 119, anc4
RAS 120.
4
Product
Description
Prepared mortar mix designed
for mortar set roof tile
applications.
Prepared tnortar mix designed
for mortar set roof tile
applications.
Single component
polyurethane foam roof tile
adhesive
Two component polyurethane
adhesive designed for
adhesive set roof tile
applications.
Manufacturer
Quikrete
Construction
Products
with current NOA
W.R. Bonsai Co.
with current NOA
Flexible Products
(with current NOA)
Polyfoam Products,
Inc.
with current NOA
Frank Zuloaga, RRC
Roofing Product Control Examiner
Table 3: Attachment Resistance Expressed as a Moment - M (ft -Ibf)
for Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15/32"
plywood)
Direct Deck
(min. 19/32"
plywood)
Battens
Flat Shake & Slate
'
2 -10d Ring Shank Nails
30.9
38.1
17.2
1 -10d Smooth or Screw
Shank Nail
7.3
9.8
4.9
2 -10d Smooth or Screw
Shank Nails
'14.0
18.8
7.4
1 #8 Screw
30.8
30.8
18.2
2 #8 Screw
51.7
51.7
24.4
1 -10d Smooth or Screw
Shank Nail (Field Clip
24.3
24.3
24.2
1 -10d Smooth or Screw
Shank Nail (Eave Clip)
19.0
19.0
22.1
2 -10d Smooth or Screw
Shank Nails (Field Clip)
35.5
35.5
34.8
2 -10d Smooth or Screw
Shank Nails (Eave Clip)
31.9
31.9
32.2
2 -10d Ring Shank Nails' 50.3 65.5 48.3
Installation with a 4" tile headtap and fasterners are located a min. of 2W from held of tile. .
•
Table 2: Restoring Moments due to Gravity - M -Ibf)
Tile
Profile
3 ":12"
4 ":12"
5 ":12"
6 ":12"
7 ":12" or
greater
Flat Shake &
Slate,
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
6.57
7.52
6.47
7.43
6.33
7.27
6.17
7.09
6.00
6.90
Table 1: Aerodynamic Multiplyers- X(ft
Tile
Profile
X (ft') ,
Batten Application
A. (ft')
Direct Deck Application
Flat Shake & Slate Tile
0.267
0.289
OLDCASTLE WESTILE, INC. ACCEPTANCE No.: 99- 1102.01
APPROVED: December 16, 1999
EXPIRES: December 16, 2002
NOTICE OF ACCEPTANCE: STANDARD CONDITIONS
4.2 Data For Attachment Calculations
5
Frank Zuloaga, RRC
Roofing Product Control Examiner
Table 4: Attachment Resistance Expressed as a Moment M (ft -Ibf)
for Two Patty Adhesive Set Systems
Tile Profile
Tile Application
Minimum Attachment
Resistance
Flat Shake & Slate
Adhesive
31.3
2 See manufactures component approval for installation requirements.
3 Flexible Products Company TileBond Average weight per patty 13.9 grams.
Polyfoam Product, Inc. Average weight per patty 8 grams.
Table 4A: Attachment Resistance Expressed as a Moment - M (ft -Ibf)
for Single Patty Adhesive Set Systems
Tile Profile
Tile Application
Minimum Attachment
Resistance
Flat Shake & Slate
PolyPro
118.9
PolyPro
40.4
4 Large paddy placement of 45 grams of PolyPro " ".
5 Medium paddy placement of 24 grams of PolyProT".
Table 4B: Attachment Resistance Expressed as a Moment - Mr (ft -Ibf)
for Mortar or Adhesive Set Systems
Tile
Profile
Tile
Application
Attachment
Resistance
Flat Shake & Slate
Mortar Set
43.9
6 Tile -Tite Roof Tile Mortar.
OLDCASTLE WESTILE, INC. ACCEPTANCE No.: 99- 1102.01
APPROVED: December 16, 1999
EXPIRES: December 16, 2002
NOTICE OF ACCEPTANCE: STANDARD CONDITIONS
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo,
or following statement: "Miami -Dade County Product Control Approved ".
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents lequired by the Building Official 'or the South Florida,
Building Code (SFBC) in order to properly evaluate the installation of this system.
6
Frank Zuloaga, RRC
Roofing Product Control Examiner
OLDCASTLE WESTILE, INC. ACCEPTANCE No.: 99- 1102.01
APPROVED: Dcccmbcr 16, 1999
EXPIRES: Dcccmbcr 16, 2002
NOTICE OF ACCEPTANCE: STANDARD CONDITIONS
PROFILE DRAWING
NAIL HOLES
7
FLAT SHAKE & SLATE TILE
a
Frank Zuloaga, RRC
Roofing Product Control Examiner
OLDCASTLE WESTILE, INC. ACCEPTANCE No.: 99- 1102.01
APPROVED: December 16, 1999
EXPIRES: December 16, 2002
NOTICE OF ACCEPTANCE: STANDARD CONDITIONS
1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been
filed and the original submitted documents, including test - supporting data, engineering documents,
are no older than eight (8) years.
2. Any and all approved products shall be permanently labeled with the manufacturer's name, city,
state, and the following statement: "Miami -Dade County Product Control Approval ", or as
specifically stated in the specific conditions of this Acceptance.
3. Renewals of Acceptance will not be considered if:
a. There has been a change in the South Florida Building Code affecting the evaluation of this
product and the product is not in compliance with the code changes.
b. The product is no longer the same product (identical) as the one originally approved.
c. If the Acceptance holder has not complied with all the requirements of this acceptance,
including the correct installation of the product.
d. The engineer who originally prepared, signed and sealed the required documentation initially
submitted, is no longer practicing the engineering profession.
4. Any revision or change in the materials, use, and /or manufacture of the product or process shall
automatically be cause for termination of this Acceptance, unless prior written approval has been
requested (through the filing of a revision application with appropriate fee) and granted by this
office.
5. Any of the following shall also be grounds for removal of this Acceptance:
a. Unsatisfactory performance of this product or process.
b. Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any
other purposes.
6. The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the
Notice of Acceptance is displayed, then it shall be done in its entirety.
7. A copy of this Acceptance as well as approved drawings and other documents, where it applies,
shall be provided to the user by the manufacturer or its distributors and shall be available for
inspection at the job site at all time. The engineer need not reseal the copies.
8. Failure to comply with any section of this Acceptance shall be cause for termination and removal
of Acceptance.
9. This Notice of Acceptance consists of pages I through 7 and this last page 8.
1
END OF THIS ACCEPTANC
8
uloaga, RRC
Roofing Product Control Examiner