Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-11-198
Scheduled Inspection Date: March 16, 2011 Inspector: Rodriguez, Jorge Owner: MCCLURY, BEVERLY Job Address: 455 NE 91 Street Miami Shores, FL 33138- Project: <NONE> Contractor: ALL FLORIDA GENERAL CONSTRUCTION Building Department Comments March 15, 2011 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 155729 Permit Number: RF -2 -11 -198 For Inspections please call: (305)762 -4949 Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile Phone Number 305 -754 -3181 Parcel Number 1132060140140 Phone: (786)255 -0340 RE -ROOF TILE Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments Page 17 of 35 Inspection Number: INSP - 155730 Permit Number: RF -2 -11 -198 Scheduled Inspection Date: March 16, 2011 Inspector: Rodriguez, Jorge Owner: MCCLURY, BEVERLY Job Address: 455 NE 91 Street Project: <NONE> Miami Shores, FL 33138- Contractor: ALL FLORIDA GENERAL CONSTRUCTION Building Department Comments March 15, 2011 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 For Inspections please call: (305)762 -4949 Permit Type: Roof Inspection Type: Up Lift Report Work Classification: Tile Phone Number 305 -754 -3181 Parcel Number 1132060140140 Phone: (786)255 -0340 RE -ROOF TILE Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments Page 18 of 35 No. RESULT No. RESULT No. RESULT No. RESULT No. RESULT 1 -5 Passed 21 -25 Passed 6 -10 Passed 26 -31 Passed 11 -15 Passed 16 -20 Passed TILE TYPE: Double Roll FLORIDA TEC' Providing Solutions to the Roofing Industry CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH METRO -DADE COUNTY PROTOCOL TAS -106 PROPERTY ADDRESS: 455 NE 91 St. Miami Shores PERMIT No: RF2 - - 198 OWNER: ROOFING SQUARES: 25 CONTRACTOR: All Florida General Construction ROOF PITCH: 3:12 INSPECTOR INITIALS: AA TEST DATE: 3111111 ATTACHMENT: PolyfoamTM 1 Polyprorm Testing Equipment: Digital Chatillon DFIS 200 Test Tabulation ReviewGa by: L3//y/1/ Alberto Cardona, P.E. -Lic #17138 10735 SW 216 St. Unit 416 Miami, FL 33170 5 14 6 .1 13 4 3 2 1 7 9 8 12 11 10 1 22 5 23 6 21 30 20 7 19 18 24 25 26 31 29 28 27 Front www.floridatec.net Lab Report No. S10 -1184 C.A. #: 26095 Lab Certificate: 09 -0715.02 Required Testing Force: 35 Ibs THIS ROOF HAS: PASSED ® FAILED ❑ THE STATIC UPLIFT IN ACCORDANCE WITH MIAMI -DADE COUNTY TAS 106. Tel: (305) 256 -4550 Fax (305) 256 -6833 NOTICE OF COMMENCEMENT A RECORDED COPY TT MUS BE POSTED POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. i t I j I I l D TAX FOLIO NO. 11- 3206-014 -0140 STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street/address: 455 NE 91st Street Miami Shores Section 2 PB 10 -37 LOT 20 BLK 49 2. Description of improvement: Reroof and repairs 3. Owner(s) name and address: JPMORGAN/ GMAC 13155 SW 42nd St., Miami, FL 33175 Interest in property: 5c.ea Name and address of fee simple titleholder: 4. Contrgctor's name, address d along number: 11,14- t.. 33 14•C � � k Ft d1. e 8. In addition to himself, Owners d 713.13(1)(b), Florida Statutes. BY Name, address and phone number: Signature(s) of Prepared By Print Name ° Title /Office STATE OF FLORIDA COUNTY OF MIAMI -DADE The forgoing iinstrument was rdividually, or Personally kno Print Name: (SEAL) VERIFICATION PURSUANT TO SECTION 92.525 FLORIDA ST Under penalties of perjury, I declare that I have read the foregoin that the facts stated in it are true, to the best of my knowledge a Signature(s) of Owner(s) or Owner(s)'s Authorized Officer/Director By By 123.01 -52 PAGE 3 9110 YOU E OF C. MEN. " ENT. 111111 C-FN 20 1 180 1 02359 DR Bk 27587 F's 2823; Ups) RECORDED 02/15/2011 10 :28 :38 HARVEY RUVIN, CLERK OF COURT MIAMI—DADE COUNTY r FLORIDA LAST PAGE Space above reserved for use of recording office 5. Surety: (Payment bond required by owner from contractor, if any) Name, address and phone number: AN t Amount of bond $ 6. Lender's name and address: A\ a STATE or FLORIDA, COUNTY OF DADE vr 7. Persons within the State of Florida designated by Owrwmgytei t tluethisnbtff i ufi s may OITh Section 713.13(1)(a)7., Florida Statutes, original filed in this e on ' of Name, address and phone number: N Il iii • +i .. esignatesthefollowingivf i .�� F a ticf • �f:rs���otic &At /— B.C. Section vOR 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN LING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YO uthorized Officer/Director/Partner/Manager Prepared By Print Name Title /Office knowledged before me this day of G CP for or • produced the following type of identification: Signature of Notary Public: 5ervedaTs vided by wham, 3s100 Z4011 NDA M. VALLEJO MY COMMISSION #D0789883 EXPIRES: MAR 17, 2012 h 1st Y : eo aoo o sl• AIDAM V LLEJO MY COMMISSK'" #DD769883 ppPr 17, 2012 0• Rate Insurance qP BUILDING PERMIT APPLICATION FBC 20 Permit Type: BUILDING JOB ADDRESS: 455 NE 91st Street DESIGNER: Architect/Engineer: NO A Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 ROOFING City: Miami Shores County: Folio /Parcel #: 11- 3206 - 014 -0140 / Is the Building Historically Designated: Yes NO Miami Dade COLOR THROUGH ROOF TILE IS REQUIRED acknowledged by: ai Permit No. 11 — 1 C T Master Permit No. CONTRACTOR: Company Name: A F lorIda C et e/A I CrfUe1i of Address: 1 %2 NW (7 ST City: M iam I State: Ft. Qualifier Name: 1 fiV ler State Certification or Registration #: CCC ( 3 . 45120 Contact Phone #: (i 16) —03 Yo Email Address: Certificate of Competency #: JG @ O; .Caark p v Phone #: M 1 5TVTIVIS iEB 0 7. Nil BY: ..:................... OWNER: Name (Fee Simple Titleholder): JPMORGAN/ GMAC Phone #: 305 551 9400 Address: 13155 SW 42nd St., City: Miami State: FL Zip: 33175 Tenant/Lessee Name: n/a Phone #: Email: Z 33138 Flood Zone: Phone #: (M)2,6S ® Zip: 3 i 4 Phone #: (- ;) z5s d 90 Value of Work for this Permit: $ I3 SOO ' Square /Linear Footage of Work: 2 0 Type of Work: ❑Address I (Alteration ❑New ❑Repair /Replace ❑Demolition Description of Work: Reroo1 (ii lei *8r3e ak*sa3aaSr84*4ra4******* **** ******** edaxit***F ....x oYaY *********xsasa4a****de4r****tYd *** Submittal Fee $ 5 0 . 00 Permit Fee $ CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) N IA Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Pi! )-A Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will no .roved and a reinspect: ,, =-e will be charged The foregoing instrument was ac day o 0 L, by NOTARY PUBLIC: O. % o gent ` a Contractor ledged before me thi The foregoing i trr was acknowledged before me this of ' at, 20 1 by is personally known to me or who has produced as identification and who did take an oath. who is personally known to me or who has produced As identification and who did take an oath. Sign: Print: My Commission Expires: APPROVED BY 4 ' 3 74=2"1/%ir MY COMMISSI r #DD769883 EXPIRES: MAR 17, 2012 Bonded through 1st State Insurance (Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/ 1 5/09Xrev6/4/ 10) Signature / // /' NOTARY PUBLIC: Sign: Print: 6 My Commis 5: My COMMISSION #DD861216 EXPIRES: P8 ruaiy 17, 2013 ,/l Bonded Tin Notary Publc UndarW tern *** *,**************************** * * * * *x* * ** *** * * *xxxxxxx *it* **w ************** * * * *xxxxxxx * * * * * * * * ***** ** * **** Plans Examiner Zoning Structural Review Clerk Feb C7 11 04:18p Florida Insurance 4 CERTIFICATE OF LIABILITY. INSURANCE PRODUCER - - ' Florida Insurance Agency Of Miami P O Eax 441340 Miami Fl 33144 All Florida General- Construction Inc 7902 NW 67 st Nib Fl 33166 COVERAGES THE POucils OF INSURANCE USTW_D BELQ HAVE see ISS USDTOTHE INSURED NAMEDABO'VE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR M3NDITior OF ANY CONTRACT OR OTHER zocuME.r WrrH rRESPELT TO WHIV-I THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFOIROEC BY r PQUOIES DE.SCR:BED HEREN 15 SUBJECT TO ALL THE TERMS, E<C:.USIONS AND CONDm6NE OF SUCH POLICIES. AGGREGATE LIMrrs SdowV MAY HAVE BEEN REDUCED 3Y PAID CLAIM. IN 7R SR TYPEOP IN BI MANCE GENERAL. L.JABL .r Y memo N. GENERAL, LABILITY CLAM MADE C AR.4GELIABILITY ANY A.L1T0 DE°DUC:TIALL5 f I RETENTION 4 woN.KERS COMPENSATION AND EMPLOYERS' - (ABILITY I AM' PROFRE OMPARTA. JEXECUTIVE OFFICEFAReESe3ER 3XOLLOE0; If vee, desr.se Leber 5t Ct.ae. Pr. ,Dv iS: DNS be o. • • OTHER s~�ERTt =ICA7E HOL,4ER ACORC 25 (001!08) OCC+JR GEHL AC* tEC,.ATE LIsar AOF FE POLCY f JpCT t I Lcc 4 7 DMDS1.E LIABILITY AIYAUTC ALL OH NEC ALYTCls SCH2Du..$D 4UTGS HIRED AUTOS NoN-DINNr.v ,fitrTOS • EXCESSPUWSRE_LA 1':-'I BtLrr COMER L173 CJUU M, CE Miami shores Village Building Dept 10050 NE 2 'ave Miami Shores F1 POLICY HUMBER 3D.A6231 WC 619297 DESCRIPTION CF OPERATiiONS r LOCAT,ON3 J VEHICLES f PS.'.^..u$j,NS AD ET ENGUR,SEISENT 1 SPEC AL PNDVISIONG 33138 MASS D: INSURER C: NSUF:E - R ?: NSLIFIER E: POLICY EFFECTIVE 'RATE IWA!JDQhY1 2 -23 -10 CANCELLATION P7JCYE#PIRATIIN DATE P4t IXOMt. -23 -11 3054451335 VHS CERTIFICATE IS IS.SU:.D AS A ONLY AND CONFERS NO RIG4TS HOLDER. THIS ERTIFICATE DOES ALTER THE COVERAGE AFFORDED INSURERS AFFORDING COVERAGE INSURER A: S.fi.., EACH CCCWSiRENCE DAMAGET0 RET,7El� FREMISES !Eaueevre:.491 MED MCP (AILa,ep I s 1 . 000 PERSONAL6 5 1 - 0QO. Q00 GHNERAL APOREGATE , S 2.„000.. 000 N'R30'JCTB - coMP!?P 463 5 ' _Orin- 7 fl f) ccasmrommuuaT tE� ademl BODC.Y INJURY t ..... (Pee Patron EOM. INJURY (Pet soeldentl PROPERTY /Perec:dere/ 1 ALTO 0Y-Y • EA.* O DENT OTHER THAN E4AC: i 5 AUTO ONLY: AGO 15 = CC:URRnNCE I s 1AGGREGATE 5 MATTER OF IN FORWLATION UPON 11h1E CERTIFICATE NOT AMEND, EXTEND OR SY THE POLICIES SELOW. LIMITS r E 1.000. 0r5 I 5 30.000 15 5 5 S P.1 rATE JAGLI P aY} NAJC# 1 R . L,WAT.:51Will C ' r h a 1 T t Y Ilhl7 f , LO -.30-1010_ 30 -111 E F �: � �Q. no : E.L. DISEASE . EA EN? LOYE 5 f to Z.L :.seAs5 - PCUCY u.s7 wig. /LDANY ABOY' i? DI: SCRteaoP01 .WCree sr. CANCELLE'O DEEM tHE WIRATSO DATE THEREOF, THE ISSUING AtrUne al WILL ENDEAVOR TD MAi_na GM'S WOMEN NITICE TO THE CERTIFICATE HO -DER NAMED 70 THE LEPT, BUT FAULURE 70 WV.: SHALL INFUSE NO OBLISATIDN OR LIABILITY OF ANY 1W4D UPON THE; INSURER. ITS AAEHT.$ OR REPRESENTATJVES. ©AC. D "•ORATION 1986 Signature Revised on 5/21/2009 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave 1 Miami Shores, Fl 33138 Re: Owner's Name: JPMORGAN/ GMAC Property Address: 455 NE 91st Street, Miami Shores, FL 33138 Roofing Permit Number: Dear Building Official: l building because: The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South FIB ; Building Code (1994 SFBC) certify that I am not required to retrofit the roof to wall connections of my L 60 ._ Print Name M iami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Date: 1 D.4:11 1 State of Florida County of Dade The undersigned, being the first duly sworn, deposes and that he/she is the owner for the above property mentioned. Swom to and subscribed before me this v-Pok day of F e ls eaurrnsul awls ls6 g6nmyt papuo8 ZI.OZ ayW S3HIdx3 Notary Public, Sate of Florida at Large 40 E8869Laa# NOISSIWWOOAW • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,00.00, and :building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. 1. SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. esthetics- Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing at the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of tJ e agree ent between the owner and the contractor. 2. " Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior moving the existing roof system). 3. , " Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or er s ould notify the occupants of adjacent units of roofing to be performed. 4-^ 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. Ponding water: The current roof system and /or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the ' inal roofing system is removed. Pounding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in a rdance with the requirements of Sections R4402, R4403 and R4413. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to • sider additional venting which can result in extending the service life of the Revised on 7/9/2009 LD 455 NE 91st Street, Miami Shores, FL 33138 Contractor Signature Date DATE: January 28, 2011 To Whom it May Concern: RE: 455 NE 91 Street, Miami Shores, FI.33138 This is to advise that Raul Gonzalez of First Service Realty Inc, is an agent acting on behalf of GMAC Mortgage concerning all matters for the property located at the address indicating above. He is hereby given authorization to pull permits on behalf of GMAC MORTGAGE. Thank You, Camille - ckso Camille Jackson Asset Manager Enterprise REO GMAC ResCap Phone: 214.874.6978 Fax: 866.352.1673 Anna.Jackson@gmacrescap.com 2711 N Haskell Ave. Ste 900 Dallas, TX 75204 Re ap ` °#" m * C ;1.. s61 C L.►'; ‘,X r-tt. 1 Cyr 6'Y• °`c-k �y 2711 N Haskell Ave Dallas TX 76204 800.799.9250 Residential Funding Corporation 1 Banking & Finance > Banking, Lending & Credit Servi... Page 1 of 3 Home Finance Resource Center 2011 Allausiness AliStar Franchises Franchises for Sale Shop Legal Forms Small Business Blog Download Center Starting a Business Operating Your Business Sales & Marketing Finance Human Resources Technology Business Library Resources Residential Funding Corporation AllBusiness has profiles of over 14,000,000 companies in the United States Related Resources Companies Search over 65 million public and private companies worldwide People Find key contact information on more than 86 million decision- makers. Industries Follow industry trends, major developments,and issues with in -depth industry profiles. Go to Hoover's.com 1 he Plum (. aid' ,lers'busin s otit +ii choose f rcxt n. ? Nvays toj)?v each fiont1 . Related Industries: Banking, Lending & Credit Services Residential Funding Corporation 1 Meridian Xing Ste 100 Minneapolis, Minnesota 55423 -3938 Company Overview Residential Funding Corporation does business In Banking, Lending & Credit Services View full company profile Stock Symbol: Line Of Business: Estimated Annual Sales: Estimated # of Employees: Year Founded: Also Known As: Estimated Employees for This Location: 350 Parent Company: Register Now to see this information. SIC Mortgage Bankers and Loan Correspondents Contact Name: Gregory B Schultz Contact Title: President Company reports from Hoover's and D &B Ads By Boogie Related Articles Computerized collections. Residential Funding Corporation Mortgage Banker /Correspondent $0 4,300 2000 Gmac -Rfc Data provided by D &B For errors or omissions on this record, update your D &B record at httpsJ /eupdate.dnb.com/, send an email to eupdate@dnb.com or phone 888- 814 -1435. Home Loans from 4.625% APR 4.925 %. Smart, Simple, Straightforward. Get Started Today! www.GMACMortgage.com NAICS Other Activities Related to Credit Intermediation More Companies In: Minneapolis, Minnesota Minnesota Search for Companies ...... • Find Sales Leads Enter a company Sign In I Join j , I About Call Nowl (866) 464 -3202 Explore our database of more than 700 Industries. Find contacts, revenue stets, and morel Search from more than 66M companies: Business Loans: What Is Factoring? • Interview with Sam Thacker, a finance expert with Business Finance Solutions. Watch More Videos Cct' -c �- • http:// www. allbusiness .com/companyprofile/Residential Funding _Corporation /6B5E039EC... 2/1/2011 [WHEN RECORDED RETURN TO] NTC ATTN:DARRELL COLON 101 N. BRAND BLVD., SUITE #1800 GLENDALE, CALIFORNIA 91203 GMACPOA St/Cnty: FLDADE 111111111111111111111111 Limited Power of Attorney KNOW ALL MEN BY THESE PREMISES: tiFEREC E. 20333PG4042 02R234362 2002 APR 17 11 =51 That JPMorgan Chase Bank, (formerly The Chase Manhattan Bank, successor in interest to The Chase Manhattan Bank, N.A.) (the name change is the result of a merger) as Trustee or Indenture Trustee (together with its successors and assigns, the 'Trustee "), under Pooling and Servicing or Indenture Agreements pursuant to which Residential Funding Corporation acts as Master Servicer, and such Trustee being, a New York Banking Corporation organized and existing under the laws of the State of New York, and having an office located at 450 West 33" Street, in the City of New York, State of New York, has made, constituted and appointed, and does by these presents make, constitute and appoint Residential Funding Corporation, a corporation organized and existing under the laws of the State of Delaware, its true and lawful Attorney -in Fact, with full power and authority to sign, execute, acknowledge, deliver, file for record, and record any instrument on its behalf and to perform such other act or acts as may be customarily and reasonably necessary and appropriate to effectuate the following enumerated transactions in respect of any of the mortgages or deeds direst (the "Mortgages" and the "Deeds of Trust ", respectively) and promissory notes secured thereby (the "Mortgage Notes ") for which the undersigned is acting as Trustee for various certificate holders (whether the undersigned is named therein as mortgagee or beneficiary or has become the mortgagee by virtue of endorsement of the Mortgage Note secured by any such Mortgage or Deed of Trust) and for which Residential Funding Corporation is acting as master servioer. This appointment shall apply to the following enumerated transactions only: 1. The modification or re- recording of a Mortgage or Deed of Trust, where said modification or re- recording is for the purpose of correcting the Mortgage or Deed of Trust to conform same to the original intent of the parties thereto or to correct title errors discovered after such title insurance was issued and said modification or re- recording, in either instance, does not adversely affect the lien of Mortgage or Deed of Trust as insured. 2. The subordination of the lien of a Mortgage or Deed of Trust to an easement in favor of a public utility company or government agency or unit with power of eminent domain; this section shall include, without limitation, the execution of partial satisfaction /releases, partial re- conveyances or the execution of requests to trustees to accomplish same. jf vkirte \5/- •IFF. REI:I L 20335PG4043 3. The qualified subordination of the lien of a Mortgage or Deed of Trust to a lien of a creditor that is created in connection with the refinancing of a debt secured by a lien that was originally superior to the lien of the Mortgage or Deed of Trust. . 4. With respect to a Mortgage or Deed of Trust, the foreclosure, the taking of a deed in lieu of foreclosure, or the completion of judicial or non judicial foreclosure or termination, cancellation or rescission of any such foreclosure, including, without limitation, any and all of the following acts: a. The substitution of trustee(s) servicing under a Deed of Trust, in accordance with state law and the Deed of Trust; b. Statements of breach or non - performance; c. Notices of default d. Cancellation/rescissions of notices of default and/or notices of sale; e. The taking of a deed in lieu of foreclosure; and £ Such other documents and action as may be necessary under the terms of the Mortgage, Deed of Trust or applicable state law to expeditiously complete said transactions. 5. The conveyance of the properties to the Mortgage insurer, or the closing of the title to the property to be acquired as real estate owned, or conveyance of the title of real estate owned. 6. The completion of loan assumption agreements. 7. The full satisfaction/release of a Mortgage or Deed of Trust or full re- conveyance upon payment and discharge of all sums secured thereby, including, without (imitation, cancellation of the related Mortgage Note. 8. The assignment of any Mortgage or Deed of Trust and the related Mortgage Note, in connection with the repurchase of the mortgage loan secured and evidenced thereby pursuant to the requirements of a Residential Funding Corporation Seller Contact, including, without limitation, by reason of conversation of an adjustable rate mortgage loan from a variable rate to a fixed rate. 9. The full assignment of a Mortgage or Deed of Trust upon payment and discharge of all sums secured thereby in conjunction with the refinancing thereof, including, without limitation, the assignment of the related Mortgage Note. The undersigned gives said Attorney -in Fact full power and authority to execute such instruments and to do and perform all and every act and thing necessary and proper to carry into effect the powers granted by or under this Limited Power of Attorney as fully as the undersigned might or could do, and hereby does ratify and confirm to all that said Attorney in Fact shall lawfully do or cause to be done by authority hereof. 4 Third parties without actual notice may rely upon the exercise of the power granted under this Limited Power of Attorney; and may be satisfied that this Limited Power of Attorney shall continue in full force and effect has not been revoked unless an instrument of revocation has been made in writing by the undersigned and recorded in the real property records of the jurisdiction in which this Limited Power of Attorney was recorded. STATE OF New York COUNTY OF New York SS. On January 29th, 2002, before me personally appeared Diane Wallace and Thomas Britt, personally known -to me or proved to me on this basis of satisfactory evidence to be the persons whose names are subjected to the within instrument and acknowledged to me that they executed the same in their authorized capacities, and that by their signatures on the instrument the entity upon behalf of which the person acted, executed the instrument. WITNESS my hand and official seal b o RISK 20333PG4044 / 0rLL 4Q.. .i k D /4:x.3 otary Public in and for the State of New York Prepared D. Colon NTC (818) 243 -7900 101 N. Brand l3ivd., Suite #1800 Glendale, CA 91203 Name: Diane Wallace Title: Assistant Vice Pr ESONI D. DAWKINS 4QdmHY PUBUC, Mote of Now Ve 1 No. 01DA6047868 Qualified in Now Yak County Coxaur nn Explipit SnU mbar 18.2002 i INICONDOIONONLOWCORDSBOOK OR8106'COUNTY. RECORD auo HARVEY RUM MIRK CIRCUIT COURT 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculation: per Chepler 16 Q . 11e, RAS 127 or RAS 128 • •.,_• • • �g. 1 4. • •.s �, . • ..• e+ • • •�, . • Other Component drePro d PP ` I • - 5. Municipal Permit Applicatio f 6. •.• •.• . • • . ; •`t Owners Notification for•Ro ofing Only 7. Any Required Roof Testing °• cula n tt enta Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 4,5,6,7 Prescriptive BUR -RAS 160 A,B,C Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 1,2,4,5,6,7 Wood Shingles and Shakes A,B,D Other As Applicable 1,2,3,4,5,6,7 0a. o SECTION 4402.14 HIGH- LOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. FLORIDA BUILDING CODE — BUILDING INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: ROOF ASSEMBLIES AND ROOFTOP STRUCTURES ATTACHMENTS REQUIRED: 000 • ° •=Y• • 800 • • • • • • • • • • • • • •.• • • • • • • ..• • • • • • • •• •• • • • •• •• ••. • • • 000 • • ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Master Permit No. . Y & Process No. � Contractor's Name HI 1 00(141A ,4 4 f COyS"I in 3nc 455 NE 91st Street, Miami Shores, FL Job Address ❑ New Roof • ❑ Low Slope ❑ Asphaltic Shingles Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) 2, S?-a ection R (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly Identify dimensions of elevated pressure zones and location of parapets. • • • • • • • gail=AAa •• • • • . •• • 11 Jx 7 •• • • • • • • r _� g. • f • • , • • 1 • • • • • • • ••• • • • • •• • • •. • as AL- • •• ••• • • •• • • • •• •• •• , • • •• 'FLORIDA BUILDING CODE — BUILDING Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Informatinn) ❑ Mechanically Fastened Tile ❑ Metal Panel/Shingles ❑ Prescriptive BUR -RAS 150 ROOF TYPE Reroofing ❑ Recovering ROOF SYSTEM INFORMATION ••• • • • • ••• • • • ••••• • • • •••••• • • • ••.•• • ••• • •• •• • • • •• •• 0 • • • • ••• • • K Mortar /Adhesive Set Tile ❑ Wood Shingles /Shakes ❑ Repair ❑ Maintenance Total (SF) 2�� Section C (Low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA ") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 or Calculations: Pmax1: Pmax2: Pmax3: Max. Design Pressure, from the specific Product Approval system: Deck: Type: Gauge/Thickness: Slope: Anchor /Base Sheet & No. of Ply(s): Anchor /Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insulation Size and Thickness: Base Insulation Fastener /Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener /Bonding Mate al: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(i) & No. of Ply(s): Ply Sheet Fastener /Bonding Material: Top Ply: Top Ply Fastener /Bonding Material: FLORIDA BUILDING CODE — BUILDING • Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. • • • • • ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Surfacing: Fastener Spacing for Anchor /Base Sheet Attachment: Field: " oc @ Lap, # Rows @ " oc Perimeter: " oc @ Lap, # Rows _ @ " oc Comer: " oc @ Lap, # Rows @ " oc Number of Fasteners Per Insulation Board: Field Perimeter Comer Illustrate Componen - oted and Details as Applicable: Woodblocking, Gutter dge Termination, Stripping, Flashing, Continuous Cleat, = nt Strip, Base Flashing, Counter - Flashing, Coping tc. Indicate: Mean oof Height, Parapet Height, Height of Base Flashing, Co ° ponent Material, Material Thickness, Fastener Type, Fast: er Spacing or Submit NiA .• .•• • • • • • •• • • •• •.•r •• • • • • -• - • • ••• • - • • • • • • • • • • • • • • • • • • • • • • • • • .- .. • • • • • • • • • ••• • • • • • • • • ••• • • • • • • • • • • • ••• • • • • • • • • • • • • •• •• • • • 00 •• • • • • 0 00 • • • Parapet Height Mean Roof Height Roofjystem anyfactu r: edij 1 e K. ook n rrde uu c U-e Notice of Acceptance Number: 06 ° 0526. 01 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): : 4 l P2: -18'4 P3: 116. Z Maximum Design Pressure (From thp Product Approval Specific System): 1 1S.S ROOF ASSEMBLIES AND ROOFTOP STRUCTURES FLORIDA BUILDING CODE — BUILDING Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. SPrfion D (Steep Sloped Roof Sysfpm) Root Slope: 12 Ridge Ventilation? N CI - - • . - . : . . - 11 - . • Deck Type: Mean Roof Height: 10 I p(i_ Type Underlayment: La* A B use . J . Insulation: Fire Barrier: Fastener Type & Spacing: TA( A( « R.s. for /ossio kat. Jg4s - - 0.G. Field l2" 0-c. Adhesive Type: ilk Type Cap Sheet: I�(M TIIc Unae/) As +� fo •. ••. • • • • • • . . • . • • • •, Type& j ebrip • • • Edge: • • • ______---• •-•--11-0-0-- • • •. . • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • •. ••.• • • • •• • • • • • • • • .•. • • Roof Covering: ' M411444 ca k � • • • • • • • • • • • • ••• • • • • ._ • • • • • • • • • • • • • • •• • • • •• •• • •• • • • ••• • • Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table I or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 6 Job Site Aerodynamic Multiplier J. Product Approval Restoring Moment due to Gravity M Product Approval Attachment Resistance Mf - Product Approval Required Moment Resistance M g Calritrat • • • • • • • • • • • Minimum Attachment Resistance F' • • • p u to • pPj�j v • • • • • • • • • Required Uplift Resistance Fr Calculated Average Tile Weight W •• • ct • Aoproval • • • • u • •• • • • • • • • Tile Dimensions L =den th g W = width • • • • • • • • • • • • PoZctuct Approval • • • • • • • • • • • • • I°, • • • All calculations must be submitted to the building official at the time of permit application. Florida Building Code Edition 2007 High- Velocity Hurricane Zone Uniform Permit Application Form. Ser-tion F (Tile Calculations) For Moment based tile systems, choose either Method I or 2. Compare the values for M with the values from Mr. If the Mf values are greater than or equal to the M values, for each area of the roof, then the tile attachment method is acceptable. Method I "Moment Based Tile Calculations Per RAS 127" Product Approval Mf 45• Product Approval Mf Product Approval Mf ( IC (PI: 45.1 x] ° 2Di = 1272.) -M8: ( = Mr1 (p. I � (P -6 x? ° 242,22.I7 ) _ Mg . Gtsq =M (P3: I I x >< °1.1 v.Sz:n - Mg: C9 .5V = M Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mf M, required Moment Resistance* Mean Roof Height -> Roof Slope .1 2:12 3:12 4.19 6:12 6:12 7:12 16' 34.4 32 2 30.4 98 4 26.4 24.4 20' 36.6 34.4 32 2 30 1 28.0 26.9 26' 38.2 36.0 33.8 31 6 29.4 27.1 30' 39.7 37.4 35.1 39.8 30.6 28.2 40' 42.2 39.8 37.3 34.9 32.4 30.0 *Must be used in conjunction with a list of moment based tile systems endorsed-by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Moment Based Tile Calculations Per RAS 127" (P1: xL = xw:= ) -W: x cos 0 (P2: x = xw:= ) - W: x cos9 x cos 0 Pa: x L = Xw•= ) -W: FLORIDA BUILDING CODE - BUILDING ••• • • • • = Frl = Fr2 = Fn • • • ••• • • • • • • • • • ••• • • • • • • • • • • • • •• • • • •• •• • • ••• • • ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Product Approval F' Product Approval F Product Approval F' MIA M t•DA[ BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Eagle Roofing Products LLC 1575 East C.R. 470 Sumterville, FL 33585 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Malibu Concrete The LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. •• •.• • • • • • •• • • • • This NOA consists of pages 1 through 7. The submitted documentation was reviewed by AM T • • • • • ••• •'•• •. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • ••• • • • • ••• • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • •• •• • • • • • •• 0 •• • • • 0 •• • • MIAMI-DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOA No..: 06- 0526.09 Expiration Date: 10 /05/11 Approval Date: 10/05/06 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Cateaorv: Roofing Sub- Cateaorv: 07320 Roofing Tiles Material: Concrete 1. SCOPE This approves a system using Burlingame Industries Malibu Concrete Roof Tile, as manufactured by Eagle Roofing Products LLC in Sumterville. FL. and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Malibu Concrete Tile Trim Pieces 2.1 SUBMITTED EVIDENCE: Test Aaencv PRI Construction Materials Technologies Redland Technologies Red land Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Test Dimensions Scatlons 1 =17" TAS 112 w= 12 1/2 thick 1= varies w = varies varying thickness Test Identifier PRI06178 7161 -03 Appendix III 7161 -03 Appendix II PO402 94 060B .• • • 94-084 ' P0631 -01•; • • • •• • TAS 112 • • ... • • • Static Uplift Testing TAS 102 & TAS 102(A) Wind Tunnel Testing TAS 108 (Nail -On) Withdrawal Resistance Testing of screw vs. smooth shank nails .....Static Uplift Testing • 'TAS 181 {A�dtle Set) • • • 1Stat!ic i�phft'Festing TAS 101 (Mortar Set) Wy ,TunfletTeSting .TAS 208 (Mortar Set) •• •• • • •• • • • • • ••• • • • •• • • • • • • .. •• • • Product Description Low profile, interlocking, high pressure extruded concrete roof tile equipped with three nail hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Name/Renort TAS 112 •••••• • • • • • • • • ..• • • • • • • • • • • • • •• • •• • ..• • • Date 08/23/06 Dec. 1991 Dec. 1991 Sept. 1993 March, 1994 May 1994 July 1994 NOA No.: 06-0526.09 Expiration Date: 10/05/11 Approval Date: 10 /05/06 Page 2 of 7 Test Aencv Redland Technologies Professional Service Industries, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing Services Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Test Identifter Letter Dated Aug. 1, 1994 224 -47099 25 -7094-1 25-7094-7 25- 7094 -4 Project No. 307025 Test #MDC -76 ❑ 25- 7183 -1 25- 7183 -2 25 -7214-2 25 -7214-6 528454-2-1 520109 -2 Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations • • Calculations • • • Calculations •• • •• • Test Name/Report Wind Tunnel Testing TAS 108 (Nail -On) Physical Properties TAS 112 Static Uplift Testing TAS 102 (4" Headlap, Nails, Direct Deck, New Construction) ❑ Static Uplift Testing TAS 102 (4" Headlap, Nails, Battens) Static Uplift Testing TAS 102 (4" Headlap, Nails, Direct Deck, Recover/Reroof) Wind Driven Rain TAS 100 Static Uplift Testing TAS 102 (2 Quik -Drive Screws, Direct Deck) Static Uplift Testing TAS 102 (2 Quik -Drive Screws, Battens) Static Uplift Testing TAS 102 (1 Quik -Drive Screw, Direct Deck) (1 Quik Drive Screw, Battens) Static Uplift Testing TAS 101 Two Patty Adhesive Set System 25 -7183 25 -7094 25 -7496 25 -7584 25- 7804b -8 25 -7804-4 & 5 • • 2i -1844 $ • • • • • • • • • • • • • • • ' ' A • • is r • • il leer tip Restoring Moment Due to Gravity •• • • • • •• • • • • • • • ••• • •• • • • • • • • • • • • • • • • • • • • • • • • • •• • •• •••• • • ••• • • • ••• • • • • •• • • • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • •• • • • • • • • • •• • • • ••• • • • • • ••• • • Date Aug. 1994 Sept. 1994 Oct. 1994 Oct. 1994 Oct. 1994 Oct. 1994 Feb. 1995 Feb. 1995 March, 1995 Sep. 1998 Dec. 1998 April 1999 March 1995 February 1996 April 1996 December 1996 Sep. 2006 Sep. 2006 NOA No.: 06- 0526.09 Expiration Date: 10/05/11 Approval Date: 10/05/06 Page 3 of 7 Table 3: Restoring Moments due to Gravity - M (ft4bf) Tile Profile 3 ":12" 4 ":12" 5 ":12" 6 ":12" 7 ":12" greater Battens or Direct Deck Malibu Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 6.30 6.65 6.21 6.54 6.08 6.41 5.93 6.25 5.77 6.08 Table 1: Average Weight (W) and Dimensions (1 x w ) Tile Profile Weight -W (Ibf) Length -I (ft) Width -w (ft) Malibu Tile 9.5 1.417 1.04 Table 2: Aerod amic Multi' Ilers - ). 1t Tile Profile 7l (ft) Batten Application A (ft Direct Deck Application Malibu Tile 0.305 0.282 3. LIMJTATIONS 4. INSTALLATION 4.1 Eagle Roofing Products LLC Malibu Concrete Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A': Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot Mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. • .. ... • • • • • .. • • • • • • . .. ... .. • • • .. .... • • ••• • • ... •• • • ... • • • • • •• ▪ • • • • • • • • • ••• • • • ... • • • . .. • • • • • • • • • • • • • • ... • • • 411 . • • • • • • • • • • •• ... • • •• •• 000 • • • ... • • NOA No.: 06-0526.09 Expiration Date: 10/05/11 Approval Date: 10/05/06 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Malibu Tile 2 -10d Ring Shank Nails 27.8 37.4 28.8 1 -10d Smooth or Screw Shank Nail 8.8 11.8 4.1 2 -10d Smooth or Screw Shank Nails 16.4 21.9 7.1 1 #8 Screw 25.8 25.8 22.9 2 #8 Screw 47.1 47.1 49.1 1 -10d Smooth or Screw Shank Nail (Feld Clip) 24.3 24.3 24.2 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2 -10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2 -10d Ring Shank Nails' ` 43.0 67.5 50.9 1 Installation with a 4' tile headlap and fastemers are located a min. of 2W from head of tie. Table 5: Attachment Resistance Expressed as a Moment MI (ft -Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Malibu Tile Adhesive 26.1' 2 See manufactures component approval for Installation requirements. 3 Fiexibie Products company TileBond Average weight per patty 11.4 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. Table 5A: Attachment Resistance Expressed as a Moment - M. (ft -Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Malibu Tile . Polyfoam PolyProTM 86.61 Folyfinini Egly_Pr2 •. 45.5b 4 Large paddy placement of 54prams of PolyPrd'". • • • • .. • O f • 5 Medium paddy placement of 24grams of PolyPro"". • _ _ _ • • •• a•• •• • • • •• ••• • • • • • • • • • ••• • • • •.• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • "' • NOA No.: 06- 0526.09 Expiration Date: 10 /05/11 • • • • • • • • • Approval Date: 10/05/06 • • • • • • • • Pag • • • •• • • • • • •. • •. • • • •• •• • • ••• • • 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved ". EAG�� LEw FLORIDA MALDIU CONCRETE ROOF TILE LABEL, SUMTERVILLE. PLANT (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. •• ••• • • • • Y •• • • • • • •• • • • • ••• • • • • • • • • • • •• •••• •• • • • •• ••• ••• • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • • • • • • • • ••• • • • ••• • • • • ••• • • • • • • • • • • • • • ••• • • • • • • •.• • • • • • • •• •• • • • •• •• ••• • • • ••• • • NOA No.: 06-0526.09 Expiration Date: 10/05/11 Approval Date: 10/05/06 Page 6 of 7 Table 513: Attachment Resistance Expressed as a Moment - Mt (ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Malibu Tile Mortar Set 20.60 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved ". EAG�� LEw FLORIDA MALDIU CONCRETE ROOF TILE LABEL, SUMTERVILLE. PLANT (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. •• ••• • • • • Y •• • • • • • •• • • • • ••• • • • • • • • • • • •• •••• •• • • • •• ••• ••• • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • • • • • • • • ••• • • • ••• • • • • ••• • • • • • • • • • • • • • ••• • • • • • • •.• • • • • • • •• •• • • • •• •• ••• • • • ••• • • NOA No.: 06-0526.09 Expiration Date: 10/05/11 Approval Date: 10/05/06 Page 6 of 7 NAL HOLE PROFILE DRAWING • MALIBU CONCRETE ROOF TILE END OF THIS ACCEPTANCE •• ••• • • • • • •• • • • • • • • • • • • .•• . • . •. • •...• •• ••• .• • • • •• ••. ••• • • • ••• • • • ••• •.• • • • • • • • • • • • • • • • • • • • • • •• ••• • • • • • • • . • • • ••• • • • ••• • • • • ••• • • • • • • • • • • • • . ••• • • •• • •••.•• • ••• • •• •• • • • •• •• ••• • • • ••• • • NOA No.: 06- 0526.09 Expiration Date: 10/05/11 Approval Date: 1W05/06 Page 7 of 7 02/07/2011 13:51 3055922451 DOLPHIN M I ♦I•D FP 4 4 pit B l i aax BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE ` OA) Polyfoam Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 Re o RF- 2l-I1— Iq$ MIA METR 140 WEST FL (305) SCOPE: This NOA is being issued under the applicable rules and regulations governing the use The documentation submifted has been reviewed by the BCCO and accepted by the Bui II Review Committee to be used in Miami Dade County and other areas where allowed b Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Mi AID (in areas other than Miami Dade County) reserve the qgt1t to have this product o !assurance purposes. If this product or material fails to performin the accepted manner, the expessae of such testing and the AHJ may immediately rcitoke, modify, or suspend I material 1 their jurisdiction. BCCO reserves the right to revoke this acceptance, i that this product or material fails to meet the requirements attic applicable building construction materials. ing Code and Product the Authority Having gh Velocity Hurricane been no PAGE 01 t -DADE COUNTY, FILOPJDA DADE FLAGLER BUILDING GLER STREET, SUITE 1603 MIAMI, FLORIDA 331313 -1563 75-2901 FAX (305) 3x15 -2908 Dade County) and/or the material tested for quality manufacturer will incur e use of such product or t is determined by 13CCO This product is approved as described herein, and has been designed to comply with the Zone of the Florida Building Code. ( DESCRIPTION: Polyproe AH160 RENEWAL of this NOA shall be considered after a renewal application has hange in the applicable building code negatively affecting the performance o r'F ERMINATION of this NOA will occur after the i ex ration date or if th ; Q +- � + to sIq"a � .t , i ge in the materials, use and/or < uuanufacture of the product or process. Misuse of this � a ��, d rt .. a � en s any oduct, for sales, advertising or any other purposes shall automatically t Ar ad . comply th any section of this NOA shall be cause for termination and removal of A DVERTISEMENT; The NOA number preceded by the words Miami -Dade County, f Florida, and followed by he expiration date. may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall sc done in its entirety. NSPECTION; A copy of this entire NOA shall be provided td the user by the manufac1 ircx or its distributors n d shall be available for inspection at the job site at the regUestl of the Building Official. 'h is NOA renews NOA No.01- 0521.02 and consists of pages 1 through 7 'h submitted documentation was reviewed by Jprge L. Acebo. r 4.4-4...._____ OA No.: 06- 0201.02 Exp Hon Date: 05/10/11 Ap royal Date: 04 /13/06 Page 1 of 7 02/07/2011 13:51 3055922451 DOLPHIN PAGE 02 ROOFING ASSEMBLY APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves Polypro® AH160 as manufactured by Pol3 'oam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure read ts, as determined by applicable building code, does not exceed the design pressure values obtained by culations in compliance with Roofing Application Standard RAS 127, for use with approved fla low, and high profile roof tiles system using Polypro® AR 160. Where the attachment calculation are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dlmensiogs Polypro® AH160 N/A Foampro® RTF 1000 N/A ProPack® 30 & 100 N/A PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Note: Teat Specifications TAS 101 Product I4esct'lption Two component polyurethane foam adhesive Dispensing Equipm(pnt Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami Dade County Product Control Accepted Roof Tile Assembly having a etarrent NOA which list moment resistance values with the use of Polypro AR160 roof tile adhesive. Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTIvl D 2127 ASTM E 96 ASTM D 2126 ASTM D 2 856 Result? 1.6 lbs./ft.' 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 LbsiFt 3.1 Perth / Inch +0.07% Volume Change -40° F., 2 weeks +6.0% Volume Change ® *58 100% Iidity, 2 weeks 86% The physical properties listed above are presented as typical average va es as determined by accepted ASTM test methods and are subject to normal manufa variation. I NOA No.: 06-0201.02 Expiration Date: 05/10/11 Al{provat Date: 04/13/06 Page 2 of 7 02/07/2011 13:51 3055922451 Celotex Cozy. Testing Services 528454 -2 -1 528454 -9 -1 528454 -10 -1 520109 -1 520109-2 520109 -3 520109 -6 520109 -7 520191 -1 520109 -2 -1 DOLPHIN EVIDENCE SUBMITTED: Test Aiencv Test Identifier Test Narne/Re Date Center for Applied Engineering #94 TAS 101 04/08/94 257818 -1PA TAS 101 12/16/96 25- 7438 -3 SSTD 11 -93 10/25/95 25 -7438-4 25- 7438 -7 SSTD 11 -93 11/02/95 25 -7492 SSTD 11 -93 12/12/95 Miles Laboratories NB- 589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtecb Laboratories, Inc. 9637 -92 ASTM E 108 Southwest Research Institute 01- 6743 -011 ASTM E 108 01- 6739- 062b[1 ] ASTM E 84 Trinity Engineering 7050.02.96 -1 TAS 114 TAS 101 TAS 101 LIMITATIONS: 04/30/93 11/16/94 01/16/95 03/14/96 10/23/98 12/28/98 TAS 101 03/02/99 1. Fire classification is not part of this acceptance. Refeitto the Prepared Roof T11 Assembly for fire rating. 2. Folypro® AH160 shall solely be used with flat, low, lit high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polypro® AH160 r1$<of tilt adhesive with their tile assemblies shall test in accordance with TAS 101. S. Roof Tile manufactures acquiring acceptance for the uoe of HANDI -STICK roc'tile adhesive with their tile assemblies shall test in accordance with TAS 401 vvith section 10.4 as .Modified herein. t W F' !2; MS OA No.: 06- 0201.02 Exp *aloe Date: 05/10/11 Ap r evel Date: 04/13/06 Page 3 of 7 PAGE 03 SI'latLow, Table 1: Adhesive Placement For Each Generic Tile Pr4fde Tile Profile Placement Detail Single Paddy Weight Min. (grams) 35 Twci Paddy Weight per paddy Min. (grams) N/A Flat, Low, High Profiles #1 High Profile (2 Piece arre! ) #1 17 /side on cap and 3 4 /pan N/A High Profiles _ #2 24 N/A Flat, Low, High Profiles #3 8 02/07/2011 13:51 3055922451 DOLPHIN PAGE 04 INSTALLATION: 1. Polypro® AH160 may be used with any roof tile assembly having a current 110A that lists uplift resistance values with the use of Polypro® AH160. 2. Polypro® AH160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof the assembly's adh4ive attachment with the use of Polypro AH160 shall provide sufficient; attachment resistance, e •ressed as an uplift based system, to meet or exceed the uplift resistance determined in comp!' - •; with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment dta is noted in the roof tile assembly NOA 3. Polypro® AH160 roof tile adhesive and its components shall be installed in atcordancce with Roofing Application Standard RAS 120, and Polyfoam Products, Inc. Polypi* AH160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualifed;Applicator' approved ancLlicensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicatirs to the authority having jurisdiction.. 5. Calibration of the Foampro® dispensing equipment is required before applicalon of any adhesive. The mix ratio between the "A" component and the "B" component shall be mnintained between 1.0- 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pcitrnds per the as determined at calibration. No other settings shall be approved. 6. Polypro® AH160 shall be applied with Foampro RTF1000 or ProPack® 30 84 100 dispensing equipment only. 7. Polypro® AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. 1 ale must be set within 2 ttt 3 minutes after Polypro® A11160 has been dispensed. 9. Polypro® AH160 placement and minimum patty weight shall he in acco •^ with the 'Placement Details' herein. Each generic tile profile requires the specific placement not - herein. LABELING: All Polypro® AH160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly/ evaluate the installation of this system. NOA No.: 06- 0201.02 E iratlon Date: 05/10/11 Approval Date: 04 /13/06 Page 4 ot7 02/07/2011 13:51 Nall ego* Attie uncwan Ens came a* from sapid% 3055922451 DOLPHIN PAGE 05 ADHESIVE PLACEMENT DETAIL 1 SINGLE PAFrrY NOA No.: 06-0201.02 Exparadon Date: 05/10/11 Aiproval Date: 04/13/06 Page S of 7 92/07/2011 13:51 3055922451 DOLPHIN PAGE 07 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY NOA No.: 06- 0201.02 Ex iratloxt Date: 05/10/11 Aprovel Date: 04/13/06 Page 6 of 7 02/07/2011 13:51 3055922451 AB ESQ PLACEMENT DETAIL 3 DOUBLE PATTY END OF TES ACCEPTANCE DOLPHIN PAGE 06 NOA No.: 06- 0201.02 'ration Date: 05/10/11 Approval Date: 04 /13/06 Pagel of7