Loading...
ROOFINGMIAMI SHORES VILLAGE APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval a the det, filed statenien• of the plans and specifications herewith submitted for the build- ing or o he- structure her i described This i-plicatic is made in compliance and con o'rn ty w.th the Building Ordinance of Mia li Shores Village, t or da, and all pro isions of the Law, c f the State of 'Acrid. all o d nances of Mi in Shores Village and all iules and regulations of the Building Div:; i of ,1 um Stern illage h '1 a o. ipl.ed with, whether herein specified or not. A copy of approved plans and specificati,ns must be kci at buiid.iig durin, progress of tl.e work. Owner' Name and Address._.. __i Registered Architect and /or Engineer _ _ Name •nd address of licem•ed contractor tom_ :_ Location and legal description of lot to be built on: Street and Number where work is to be done BUILDIN INSPECTION DEPARTMEN __ Subdivision Date era _ y No.._. ___ Street. 19 State work to be done and purpose of building (by floors) . \ ` 4 „ T - / _. h ��. r' 4 5 4.. __ o - \ ,.,t :. .1 °- _ . _ and for n her purse. New Building_ _ Remodeling _ ___ _ .. __ Addition. _ . _ .. _- . Repairs _ _ No. of Stories To be constructed of _._ _ Kind of foundation _ _ __ Roof Cov -ring _ . ' `t . Estimated T ,tal cost of improvements $__ S \ _ ._..._ Amount c. c Permit $._ _ _ Zone ^ubage required __. _Plan Cubage_ ._ _._ .. ___ __._ Distance to next nearest building. .. __Size of Building Lot - Maximum live load to be borne by each floor hereby submit all the plans and specs i.•ations for said building All notices with reference to the building and its construction may be sent to .. __ _ _ ___ . _ The uncle signed appli ant for th's building pc -mit does hereby certif% i'iat he underitar_ds and accepts his .•bligations as an criij lob er of 1 bor t.nder he Florida Workmen's Compensation Act bc•ng S - -ton " 63 Co. a led Ccn al Laws of Florida P r anon S'.pt,l. ent. and h s compl ed w'th he prov'.ions thereof, and will require s miiar col ' . ran .e froin :ill contractors or sub contrictor, cnrplo .ed b) hint in the 1,-,, k to be p ri med under th s pern it and - ill post or raw; to Je , tested fi,r inspection on the site of the work su -h public not e or otices as are regwr d i-y the Act. The u r fig i d agrees to emplo) oily sc:.h iheon'r ctors, on work to be perform d . der this permit as are lrcenseri by M am, Shores \ il ge. r Remarks (S`F!cd)� ! - `, .L.. - -, STATE OF FI,ORTDA, COUNTY OF DADE. } ss. Date. Permit No._ _._ ____ _. _ _- _ Disapproved -> Date _ (Signed) Buildikig Inspector My Cain :ors -inn Expires Read, Sworn to and Subscribed before me. Notary Public State of Florida Before me, the undersigned authority, a notary public, duly authorized to adn'.nister oaths ..nd take acknowledgments, per_onall: p peared to me well known, and who, being by me first d ly cworn, upon oath deposes and says that he is the of th abov. de .c ibed tstruction t. 1, has careially read the foregoing application, and that he did sign the same, and it a'. ' .tcts therein by hum stated are tr ie. PLANNING BOARD___________ ___ _ _ ___ -DATE Chairman __ --. Member . . . . . ....... ... Member Member ..... - - . -.... Member Meri be • Council Approved Date Di's.. ,r:n...t Date NOTE: A charge of $1.00 will be made for making correctians c- -h .nges to this application ft.•r ei proval 1, s 1 et a 'ita ocd from the Planr ng Board A re- inspection fee of $1.00 will be charged when such re- inspection is mi n« .es h.• improper notice ft r imp t ,, • or l r' ty materials and /or workmanship. -�_ Registered Architect and /or Engineer Name and address of licensed contractor., Location and legal dcscr tion of lot to be bun on: Lot.J 2 1 � 2 1, Block I Permit No. ._ .... Disapproved (Signed) MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMUT Application is hereby wade for the approval of the detailed statement or inc plans and specifications herewith submitted for the build ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Mum Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. 19.. 'J. Owner's Name and Address ....: %!� .hr� � •- � _. No..:. i.. .. Street._ .. ..�. e Date Building Inspector Subdivision Street and Number where work is to be done State work to be done and ,purpose of building (by floors) Lt-lvo Date. Chairman Mcrr,ber Nfember �....._......_..._.�..... Council Approved Member Member Member Date Disapproved My Commission Expires PLANNING BOARD DATE .,...,,t..,,,.,f.,fl,...,, ,..- Read, Sworn to and Subscribed before me. Notary Public, State of Florida NOTE: A charge of $1.00 will be made for making corrections the Plannir.g Board. A re inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice materials and /or workmanship. or changes to this application after approval .3 - /2 o% 2. Z". for no other purpose. New Bui!ding Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Covering c ey c Estimated Total cost of improvements $. i gc Amount of Permit Si_ V Zone cubage required .Plan Cubage Distance .to next ne building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to.. The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 59G6, Compiled General Laws of Florida, Permanent Sup itentent, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be post . . ection the site of the work such public notice or notices as arc required by the Act. The undersigned agrees to employ only su h su • • actor on or toobe performed .under this pcnnit, as are licensed by Miami Shores Village. Remarks (Signed)_ .. . STATE OF FLORIDA, COUNTY OF DADE. ss Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stat dd�ar true.. � . ... f .3 Date has been obtained from for inspection or faulty MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT • APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. 192± Owner's Name and Address W K c ( 1.e , No . s Street--9 Registered Architect and/or Engineer ,., 1•.^, IV 711,, Name and address of licensed contractor i3 $c: iZ047 f - tAilf • -•? 37 - /1 t 9 Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done I/ 43..../V r State work to be done and purpose of building (by (loors) e" Eh11 i1tf 7/AI lc> e Au? 9 a re . AP/ d W e G . re &Mel tc')+LT". 7iL co and for no other purpose. New Budding Remodeling Addition Repairs No. of Stories. ONC To be constructed of . Kind of foundation Roof Covering / F SIP! ...... Estimated Total cost of improvements $ a 2 f 7' e Amount of Permit Zone cubage required _Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor._ I hereby submit all the plans and specifications for said building. All notices with reference to the building ard its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligaticns as employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Slip and has complied with the provisions thereof, and will require similar compliance from all contractors or sub employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such beontractors, on work to be performed under this pennit, as are licensed by Miami Shores Village. Remarks (Signed) I' c jr ) • • STATE OF FLORIDA, COUNTY OF DADE. ss. peared Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No.. it" . Date 2 , 9 Read, Sworn to and Subscribed before rne. Disapproved Date (Signed) 147 r Notary Public, State of Florida Building Inspector My Commission Expires PLiVICINING BOARD DATE Chairman Member Member Niember Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.(X) will be made for making corrections or changes to this application after approval has been obtained from the PiAnning Board. A re-inspection fee of SLOB will be charged when such re-inspection is made necessary by improper notice for inspection or faulty materials and/or workmanship. PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 0/ t I) Job Address 933 /le 9/-"i :C Tax Folio Legal Description Historically Designated: Yes No L" NI A A !'\ 16 t- f • 1 E (` Master Permit # / J , / t/ Owner/Lessee / Tenant Contracting Co. ` / /`C �✓' t 7 /1 t Address / 4C , V AA '114 (4 Owner's Address State # CgC &1 Municipal # Architect/Engineer /40 9 Bonding Company A Mortgagor Qualifier OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be do construction and zoning. Furthermore, I authorize the above -named contractor to ¢o the work sta Signature' of owner and/oc•Condo President Notary as to Owner and/or Condo President. IDRON My Commission E'� .. • - • ' - 73703 & t r r .. 0 30 Vvl I ..I.J 'e0; W ATLANTIC BONDING CO., INC. FEES: PERMIT APPROVED: Zoning Mechanical RADON Date Address Address Address Phone 7 3 ,� ,o 6 Er SS# (/'' - - Phone = 5 Competency # R' ;void26. / Ins. Co. Electrical 1 -- Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN RCM WORK DESCRIPTION CM L /9 -L (` 6 6 f (iJ g r /1- 1 EL- r % Te (-' i A• () PE (r t ._ 6 / i c'-. G c.-ey_ y_) 77 Square Ft. 3 I 4/ : /� —C 2-° - -eit.Y Estimated Cost (value) °!" WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. s ' Bence wi Signature of Contractor Owner-J3uilder Notary as to Contractor or Owner- Builder My Commission Expires: 4iltY10 ELIA ISIDRON j COMMISSION # CC 573703 BONDED THRU E:;SI„ _G AUC. 10. 2000 .141. ATLANTIC BONDING CO., INC C.C.F. � NOTARY BOND 9& ✓ ,/f TOTAL DUE all appli flaws regulating Date Date Structural Engineer NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with N Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. I� 1. Legal description of property and street address: 1433 NE. 91 ST"' MIAMI SHO2ES FL M► AMI SH QES GEc 2. p 10 -37 %LOT 1'1 + W ` 2 LOT I _ iLk y 2. Description of improvement: RE 2o0 F 2100 sot? FT 0"F - 7 - ILA. Roo (boo SQ Q FT OF Owner(s) name and address: M A It I A E • ki QCt4 ESL '4?'3 N' ST I AM 1 SNOA.es F[_ 33135 cats • Interest in property: Name and address of fee simple titleholder: Ivt t el Au K 12-c 4. Contractor's name and address: I.4 4- .. 4 " N.0 DE. L.1 N 6 5. Surety:(Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 6. Lender's name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),- Florida Statutes. Name and address: 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) Signature of Owner Print Owners Name ,o l 4 ,41 E k'4!/1 Sworn to and subscribed befor- me this 2 day of Notary Public Print Notary's Name My Commission Expires: t0L4o NW (Cfi N • AIM&( FL, 33 149 t:. [[x''111 EXPIRES AUG. 10. 2000 te n`! BONDED THRIJ OM' ATLANTIC BONDING CO., INC. S7ATici OF FLORIDA, COUNT OF CADE 1;Q f 3 yCcRTh =Ythatthisisatruecoyo!the orrgInai filed in this office on day of /9 -4./ 1 -/--S - 77___ , A D 20 49 0 V✓ITNSS y hand and Official Seal. HARM App RI(, of Cu end County Courts By D.C. 11 -32 -060-014 -0120 Prepared by: Address: &i18 /S,'I ota /'/oda AJ& G / ,v 33 /k • 123.01.52 2193 Contractor's Name: 14 14 R # 4OOCUN( ROOF CATEGORY �/ (Low Slope Application) ❑ (Nail -On Tile) !((Mortar - Adhesive Set Tile) ❑ (Asphalt/Fiberglass Shingles) ❑ ( Metal Roofs\Wood Shingles & Shakes) ❑ (Other) ROOF TYPE ❑ New Roof Re roofing ❑ Recovering ❑ Repair ❑ Maintenance Flat Roof Area (f1 t . Sloped Roof Area (ft') e21D0 Total (ft') i 00 Master Permit No. Exposure category (per ASCE 7 -88): Building Classification category (per ASCE -88 table 1): Ft. Ft. 123.01 -78 9/96 • /� � M Deck type: W V I 6 * ( • V Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. ROOF HEIGHT AND SYSTEM DETAILS ATTACHMENT Fastener Type: 1 /4 a/5 Field: 11 Perimeter: (p 0 .0 Corner: lO.Oe DETAIL 1 & 2 SPACING Job Address: 1 43 3 N E T ST' (Draw &c I ids as needed . p. P R ' ,� � .11Q 9,14 t Page -1 r ROOF PLAN r r i r r ' r Appendix "E UNIFORM ROOFING PERMIT APPLICATION PROCESS No. Ridge Ventilation? MEAN HEIGHT ! I Deck type: &DOD /XGTC z Underlayment: Insulation: O E T A I L 3 SLOPED SYSTEM DESCRIPTION 01' 30 12" ROOF SLOPE N.4 Fastener type & spacing: / 'V /200 G o e co&rv. Cap Sheet: .. gel Roof Covering: moivoie O8( t&a Rgvf ricfs • Drip edge: • 3 " X 3" 641ck E•i ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation . • c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals TILE CALCULATIONS (Pmax1: ° x X (Aerodynamic Multiplier): a ) - M .C.319= M rl : 161 PCA: �� (Pmax2: % % x ?t, (Aerodynamic Multiplier): A•4/ ) - M = M PCA: is • (Pmax3: x ?t (Aerodynamic Multiplier): ) - M 4' M 141 PCA: ° 4: / Page -2 J J J J -•1 APPENDIX "F" REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS As it pertains to this Appendix "F ", it is '.!:_ respo:!_ ibility of the roo!ing contractor to provide the owner with the required roofing permit, to provide the owner with this appendix and to explain to the owner the content of this form. The provisions of Chapter 34 of the South Florida Building Code (SFBC) govern all the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained. 41 Aesthetics - Workmanship:. The ■vorktuanship provisions of Chapter 34 are Ix the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architect..: 7a! appearance. that are not part of , ,nnint code, should be addressed o � ss:.� s Hart of the agreement between the owner and the contractor. 711(12. Renailing Wood Decks: When replacing roofing. the existing wood roof deck may have to be renailed in accordance withlthe current provisions of Chapter 29 of the SFBC. (The roof deck is usually concealed prior to removing the existing roof system) r 714V Common Roofs: Comnton roofs are those which have no visible delineation between nei�_hboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and /or owner should notify the occupants of adjacent units of roofing work to be perforated. *64,4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed - from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The SFBC provides the option of.mainrinin this appearance. Ponding Water: The current roof system and /or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structurat engineer. Fording may shorten the life expectancy and performance of the new roofing system. Ponding conditions may no be evident until the original roofing system is removed. Ponding conditions should be corrected. Me1 Overflow Scuppers. (wall o-uttet•s): It is required- that rainwater flow off so that. lluc roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge overflow scuppers (wall outlets) are not provided. It may be. necessary to install overflow scuppers in accordance v: ith Chapter 23 of the SFBC. f 1/ L ik - 7. Ventilation: i\'lost roof structures should have some ability to vent natt:ra 1 airflow through the interic of the structural assembly (the building itself). The existing amount of attic ventil :lion shall no be reduced. 1: may be beneficial to consider additional venting which can result in extendin�, the service life of the roof. J ��`S The owner may contact the Miami-Dade County Consumer Scr i:cs Departmeit: for f: ::her tdforntation regarding the above. N{i 1L Owner's /Agent's Signature /// 4/00 Uatc Contractor's Si■c!;t:tturc METP0 -0 METROPOLITAN DADE COUNTY, FLORIDA PRODUCT NOTICE OF ACCEPTANCE (305) 375 -2901 Monier Lifetile LLC FAX (305) 375 -2908 135 NW 20 St. Boca Raton, Florida 33431 Your application for Product Approval of: Monier Lifetile LLC Villa, Capri, & Roll Tiles under Chapter 8 of the Miami -Dade County Code governing the use of Alternate Materials and Types of Construction, and coy oletely described in the plans, specifications and calculations as submitted by: Redland Technologies, Se Center for Applied Engineering, Inc., and Professional Service Industries has been recommended for zcceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions set forth on pages 2 -14 and the standard conditions on page 15. This approval shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Building Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. ACCEPTANCE NO.: 97- 1124.16 EXPIRES: 06/25/01 Revises: 95- 0322.07 95-0322.03 95- 0316.04 APPROVED: 06/25/98 1 Miami -Dade County METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 PRODUCT CONTROL DIVISION (305) 375 -2902 FAX (305) 372-6339 1 Rodriguez Product Control Supervisor THIS IS THE COVERSHEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Miami -Dade County Building Code Compliance Office and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. L i t ee , t,t Charles Danger, P.E. Director Building Code Compliance Dept. MION ER LJFETILE LLC Product Control No.: 97- 1124.16 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Product Dimensions Monier Lifetile 1 = 16'/2" LLC Villa & Roll w = 13" '12" thick Monier Lifeitile LLC Capri Tile Trim Pieces Product Rainproof II Ice and Water Shield L= 17" W= 12 3 4" Y2" thick 1= varies w = varies varying thickness 30 "x 75' roll 36"x75'roll or 60 "x75' roll 36" x 75' roll Test Specifications PA 112 PA 112 PA 112 Test Dimensions Specifications Page 2 of 15 Product Description Low profile, interlocking, high pressure extruded concrete roof tile equipped with one nail hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Low profile, interlocking, high pressure extruded concrete roof tile equipped with one nail hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Product Description Manufacturer PA 104 Single ply, nail -on Protect -O -Wrap, underlayment with Inc. 2" self-adhering top (with current NOA) edge. PA 103 Self- adhering W.R. Grace Co. underlayment (with current NOA) Frank Zuloaga, RRC Roofing Product Control Examiner MONIER LIFETILE LLC Product Wood Battens Tile Nails Tile Screws Roof Tile Mortar ("TileTitet") Roof Tile Mortar ( "Quikrete® Roof Tile Mortar #1140") Roof Tile Mortar ( "BONSAL® Roof Tile Mortar Mix") Roof Tile Adhesive ( "Polypro® AH160") Hurricane Clip & Fasteners Dimensions Vertical Min. 1 "x 4" Horizontal Min. 1 "x 4" for use with vertical battens or Min. 1 "x 2" for use alone Min. 8d x 2 %:" or min. 10dx 3" #8x 2 W' long 0.335" head dia. 0.131" shank dia. 0.175" screw thread dia. N/A N/A N/A N/A Clips Min. 'A" width Min. 0.060" thick Clip Fasteners Min. 8d x 1 'A" Test Specifications Wood Preservers Institute LP — 2 PA 114 Appendix E PA 114 Appendix E PA 123 PA 123 PA 123 See PCA Page 3 of 15 Product Control No.: 97- 1124.16 Product Description Salt pressure treated or decay resistant lumber vattens Corrosion resistan generic screw or smooth shank nails Corrosion resistant, generic coated, square drive, galvanized, coarse thread wood screws Prepared mortar mix designed for mortar set roof tile applications. Prepared mortar mix designed for mortar set roof tile applications. Prepared mortar mix designed for mortar set roof tile applications. Two component polyurethane adhesive designed for adhesive set roof tile applications. Manufacturer generic Bermuda Roof Company, Inc. with current PCA Quikrete Construction Products with Current PCA W. R. Bonsai Co. with current PCA Polyfoam Products, Inc. PCA #94- 0401.01 PA 114 Appendix E Corrosion resistant Generic clips with corrosion resistant nails. MONIER LIFETTLE LLC Test Aeencv Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. EVIDENCE SUBMITTED Test Identifier Test Name/Report Date 7161 -03 Appendix III 7161 -03 Appendix III 94-084 94 -060B 25- 7094 -1 25- 7094 -7 25- 7094 -4 25- 7183 -1 25- 7183 -2 Page 4 of 15 Product Control No.: 97- 1124.16 Static Uplift Testing Dec. 1991 PA 102 Static Uplift Testing Dec. 1991 PA 102(A) Static Uplift Testing May 1994 PA 101 (Mortar Set) Static Uplift Testing PA 101 (Adhesive Set) Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, New Construction) Static Uplift Testing PA 102 (4" Headlap, Nails, Battens) Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, Recover/Reroof) Static Uplift Testing PA 102 (2 Quik -Drive Screws, Direct Deck) Static Uplift Testing PA 102 (2 Quik -Drive Screws, Battens) March, 1994 Oct. 1994 Oct. 1994 Oct. 1994 Feb. 1995 Feb. 1995 uloaga, RRC Roofing Product Control Examiner MONIER LIFETILE LLC Test Aaencv The Center for Applied Eng.:neerirrg, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Professional Service Industries, Inc. Test Identifier 25- 7214 -2 25- 7214 -6 7161 -03 Appendix II Letter Dated Aug. 1, 1994 P0631 -01 PO402 Project No. 307025 Test #MDC -76 224 -47099 Page 5 of 15 Product Control No.: 97- 1124.16 Test Name/Report Date Static Uplift Testing PA 102 (1 Quik -Drive Screw, Direct Deck) Static Uplift Testing PA 102 (1 Quik -Drive Screw, Battens) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Driven Rain PA 100 Physical Properties PA 112 March, 1995 March, 1995 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Oct. 1994 Sept. 1994 MONIER LIFETIME LLC Product Control No.: 97- 1124.16 Deck Type: Wood, Non- insulated Deck Description: New Construction 19 /32" or greater plywood or wood plank. SYSTEM A: Counter -Batten Application Slope Range: SYSTEMS 2 ":12" to 7 ":12" Note: Counter - Battens, as noted below, are required for slope range 2 ":12" to less than 4 ":12" and are optional for slopes of 4 ":12" to 7 ":12 ". For slopes exceeding 7 ":12 ", refer to System C. Underlayment: Install underiayment system in compliance with Dade County Application Standard PA 118. Vertical Battens: Install vertical battens in compliance with Dade County Application Standard PA 118 Horizontal Battens: Install horizontal battens in compliance with Dade County Application Standard PA 118. Roofing Tile: Install tile in compliance with Dade County Application Standard PA 118. (See "Data for Attachment Calculations" included in this Approval.) Comments: 1. For re -roof applications, 15 /32" plywood is an acceptable substrate. Page 6 of 15 Roofing Product Control Examiner MONIER LIFETILE LLC Product Control No.: 97- 1124.16 Underlayment: Roofing Tile: Comments: SYSTEMS (CONTLNUED) Deck Type: Wood, Non - insulated Deck Description: New construction 19 /32" or greater plywood or wood plank. SYSTEM B: Direct Deck Application Slope Range: 4 ":12" to 7 ":12" Note: System B is only acceptable in this slope range. For slopes less than 4 ":12 ", refer to System A. For slopes in excess of 7 ":12 ", refer to System C. Install underlayment system in compliance with Dade County Application Standard PA 118. Install tile in compliance with Dade County Application Standard PA 118. (See "Data for Attachment Calculations" included in this Approval.) 1. For re -roof applications, 15 /32" plywood is an acceptable substrate. Page MONIER LIFETELE LLC Product Control No.: 97- 1124.16 Deck Type: Deck Description: SYSTEM C: Slope Range: Underlayment: Horizontal Battens: Roofing Tile: Comments: SYSTEMS (CONTINUED) Wood, Non- insulated New construction 19/32" or greater plywood or wood plank. Horizontal Batten Application 4 ":12" or greater Note: Horizontal battens, as noted below, are required for slopes in excess of 7 ":12" and are optional for slopes of 4 ":12" to 7 ":12 ". For slopes less than 4 ":12 ", refer to System A. Install underlayment system in compliance with Dade County Application Standard PA 119. Install horizontal battens in compliance with Dade County Application Standard PA 119. Install tile in compliance with Dade County Application Standard PA 119. (See "Data for Attachment Calculations" included in this Approval.) 1. For re -roof applications, 15 /32" plywood is an acceptable substrate. Page 8 of 15 Frank Zuloaga, RRC Roofing Product Control Examiner MONIER LIFETtLE LLC Product Control No.: 97- 1124.16 SYSTEMS (CONTINUED) Deck Type: - Wood, Non - insulated Deck Description: New construction 19 /32" or greater plywood or wood plank. SYSTEM D: Mortar or Adhesive Set Application Slope Range: 2 ":12" to 7 ":12" Note: System D is only acceptable in this slope range. For slopes in excess of 7 ":12 ", refer to System C. Underlayment: Install underlayment system in compliance with Dade County Application Standard PA 120. (See System Limitation #5.) Roofing Tile: Install tile in compliance with Dade County Application Standard PA 120. (See "Data for Attachment Calculations" included in this Approval.) Comments: 1. For re -roof applications, 15 /32" plywood is an acceptable substrate. Page 9 of 15 ran Zuloaga, RRC o .. -a -- n_.I.. -. r- .. -. - -i c.. - -. - .... MONIER L• IFETILE LLC Product Control No.: 97- 1124.16 SYSTEM LIMITATIONS 1. The standard minimum roof pitch for Monier Lifetile LLC Villa, Monier Lifetile LLC Capri & Monier Lifetile LLC Roll, low profile tile shall comply with Dade County Application Standards PA 118, PA 119 or PA 120, depending on the method of installation. 2. For nail - on applications, fasteners for mechanical attachment of tiles shall have a head diameter larger than that of the preformed holes in the tile. 3. System installation shall be in compliance with the system specifications outlined in this Product Control Approval. The method of attachment utilized shall provide sufficient attachment resistance to meet or exceed the required resistance determined in compliance with Dade County Protocol PA 115 or PA 127. Tile profiles listed here in have been tested for both wind characteristics and static uplift performance, therefore, attachment calculations for installation in compliance with PA 115 or PA 127 shall be done as a 'Moment Based System'. 4. For adhesive set tile applications, a field static uplift test by a Dade County accredited testing agency, in compliance with Dade County Protocol PA 106, shall be performed. 5. For tile applications, 30/90 hot mopped underlayment applications may be installed perpendicular to the roof pitch unless stated otherwise by the underlayment material manufacturer's published literature. 6 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo for identification in the field. 7. Applications for roofing permits shall include a completed Section II of the Uniform Building Permit, a copy of manufacturer's current specifications and details, a copy of this Product Control Approval and a copy of the Product Control Approval of any Roofing Component used in the proposed tile application. Reference shall be made to appropriate data for the required fire rating. 8. The applicant shall retain the services of a Dade County certified testing laboratory to maintain quality control in compliance with the South Florida Building Code and related protocols. Samples taken shall be in compliance with Dade County Protocol PA 112, Appendix 'A'. 9. Fire classification is not part of this aceptance. Page 10 of 15 Frank Zuloaga, RRC Roofing Product Control Examiner Table 1: Aerodynamic Multipliers - X (ft Tile X (ft') X (ft') Profile Batten Application Direct Deck Application Monier Lifetile LLC Villa Tile, 0.27 0.29 Roll Tile, and Capri Tile MON 1ER LIFETILE LLC Table 2: Restoring Moments due to Gravity - M (ft -Ibf) 3 66 :12" 4 ":12" 5 ":12" 6 ":12" Tile Profile Monier Lifetile LLC Villa Tile, Roll Tile, and Capri Tile Tile Profile Monier Lifetile LLC Villa, Roll, and Capri Batten s 5.57 Direct Deck 6.30 Tile Application Battens Batten s 5.48 DATA FOR ATTACHMENT CALCULATIONS Direct Deck 6.18 Approved Nails 1 nail 4.10 2 nails 7.10 Batten $ 5.37 1 screw 22.90 Page 11 of 15 Direct Deck 6.05 Approved Screws 2 screws 49.10 Product Control No.: 97- 1123.16 Batten 5.24 1 nail 24.20 Direct Deck 5.90 Table 3: Attachment Resistance Expressed as a Moment - Mt (ft -Ibf) for Nail -On Systems Approved Field Clip With: 2 nails 34.80 r:12" or greater Batten Direct s Deck 5.09 Approved Eave Clip With: 1 nail 22.10 N/A 2 nails 32.20 Direct Deck 11.80 21.90 25.80 47.10 24.30 35.50 19.00 31.90 1 Data noted in Table 3 is for installation with a 3" tile headlap. 2 Approved screws are as noted in the Trade Names of Products Manufactured By Others' and 'Profile Drawings' sections of this Approval. Clips on eave tile are not required for this attachment configuration unless the Required Moment of Resistance exceeds the values noted above. MONIER LIFETILE LLC DATA FOR ATTACHMENT CALCULATIONS (CONTINUED) Product Control No.: 97- 1124.16 Table 3 -A: Attachment Resistance Expressed as a Moment - M1 (ft -Ibf) for Nail -On Systems Tile Profile Monier Lifetile LLC Villa Tile, Roll Tile, and Capri Tile Tile Application Battens New Construction Two (2) 10d x 3" long nails 67.50 43.00 Direct Deck New Construction (min. 3 / 3 2' plywood) Direct Deck Recover/Reroof (min. ' %" plywood) 50.90 1 Tile installation with a 4" headlap using two (2) Approved 10d x 3" long polymer coated, corrosion resistant, ring shank nails installed in manufactured holes located 2W from the head of the tile. Clips on eave tile are not required for this attachment configuration unless the Required Moment of Resistance exceeds the values noted above. Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar or Adhesive Set Systems Tile Tile Attachment Profile Application Resistance 20.60 Monier Lifetile LLC Villa Tile, Roll Tile, and Capri Tile Mortar Set Adhesive Set 86.61 Page 12 of 15 uloaga, RRC Roofing Product Control Examiner MONIER LIFET1LE LLC PROFILE DRAWINGS MONIER LIFETILE LLC VILLA TILE MONIER LIFETILE LLC ROLL TILE Page 13 of 15 Product Control No.: 97- 1124.16 ' MONIER LIFETILE LLC .07 • PROFILE DRAWINGS (CONTINUED) MONIER LIFETILE LLC CAPRI *******0 CAW APPROVED SCREW FOR SCREW DATA IN TABLE 3 Page 14 of 15 1.711" Product Control No.: 97- 1124.16 0.131 Roofing Product Control Examiner 0.175- MONIER LIFETILE LLC Product Control No.: 97- 1124.16 Monier Lifetile LLC ACCEPTANCE NO: 97- 1124.16 135 N.W. 20 St. APPROVED : June 25. 1998 Boca Raton, FL. 33431 EXPIRES : June 25 2001 NOTICE OF ACCEPTANCE STANDARD CONDITIONS 1 Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2 Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3 Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied.;vit -all the requirements of this acceptance, including the correct installation of the product d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4 Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5 Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6 The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7 A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer. 8 Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9 This Acceptance contains pages 1 through 15. END OF THIS ACCEPTANCE Page 15 of 15 k METRO METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE 140 WEST FLAAGLER ET SUIT 0 1603 L MIAMI, FLORIDA 3 3130.1586 3 (305) 375 -290 FAX (305) 375 -2908 PRODUCT CONTROL NOTICE OF ACCEPTANCE PRODUCT CONTROL DIVISION (305) 375-2902 FAX (305) 372 -6339 GAF Materials Corporation 1361 Alps Road Wayne, Ni 07470 Your application for Product Approval of: GAF Conventional Built -Up Roof Systems for Wood Decks under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Dynatech Engineering, Inc, Factory Mutual Research Corporation, and Underwriters Laboratories, Inc. has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions set forth on pages 2 -40 and the standard conditions on page 41. This approval shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the'Building Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compliance Office reserves the right to revoke this approval,.if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.: 97-0804.21 Revises No.: 95- 1003.03 Expires: 11/04/00 Approved: 11/04/97 y 1 aul Rodriguez Product Control Supervisor THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Office and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. Charles Danger. P.E. Director Building Code Compliance Dept. Metropolitan Dade County Internet mail address: postmaster@buildingcodeontine.com 9 Homepage: http://w 5 Applicant: GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING SYSTEM APPROVAL Category: Membrane Roofing System Sub - Category: Built -up Roofing Type: Conventional Sub -Type: Fiberglass Product Control No: 97- 0804.21 . Product Control No.: 97 -0 80_ Approval Date: November 4, 1997 Expiration Date: November 4, 2000 System Description GAF Materials Corporation, a manufacturer of commercial roofing products for more than 100 years, produces a wide range of roof products for built -up and modified bitumen roofing systems. In addition, GAF offers two ply modified systems to meet the demands for multi -ply SBS modified specifications. GAF provides warranted systems over various insulated and non - insulated substrates, copies of which can be obtained from GAF and can be found in the "GAFGLAS Built -Up Roofing Application and Specifications" manual published annually. GAF roof system assemblies have been extensively tested at Factor~. Mutual Research Corporation and Underwriters Laboratories and have been tested in compliance with all requirements of the South Florida Building Code. Specific classifications for assemblies are listed in the current L.L. Roofing Material ,Directory and the current Factory Mutual 'approval Guide. GAF Materials Corporation products are distributed through a wide network of roofing wholesale distributors throughout the South Florida area. For more information on specific roof system constructions, contact the Technical Set- ice Office, located in Wayne, New Jersey, at 1- 800 - ROOF -411. Contact: William J. Woodring Director of Technical Services (973) 628- 4134 Page 2 of 41 ran Zuloaga, Roofing Product Control Examiner Product GAF Asphalt Concrete Primer GAF Mineral Shield® Granules GAF WeatherCoat® Emulsion GAF Premium Fibered Aluminum Roof Coating GAF Jetblak All Weather Plastic Cement RUBEROID® `codified Bitumen Flashing Cement Jetblack Premium Flashin, Cement G.AFGLASF '5 . GAFGLAS 480 Ultima Base Sheet GAFGLAS Ply 6® GAFGLAS Flex PIyTM6 ( GAFGLAS Ply 4® Product Control No: 9797 - 0804.2 1 • TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Test Product Dimensions pccification Description 5, 55 gallons ASTM D 41 Asphalt concrete primer used to promote adhesion of asphalt in built -up roofing. 60 Ib. bags ASTM D 1863 Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral Shield® Granules shall be used for flashing applications only. 5 gallons ASTM 1227 Surface coating for smooth surfaced roofs. 1, 5 gallons ASTM D 2824 Fibered aluminum coating. 1, 5 gallons 5 gallons 5 gallons 3 sq. roll 75 lb. roll 2 Sq. Roll 70 lbs.!rol l 5 sq. roll 45 Ib. roll 5 sq. roll 45 Ib. roll ASTM D 4586 Fiber reintbrced. polymer modified Flashing cement .AST\.1 D 4586 Asphalt flashing Cement ASTM D 3019 Refined asphalt blended with a mineral ASTM D 3409 stabilizer and fibers. Permits adhesion to wet and dry surfaces. ASTM D 4601 Asphalt impreQnated and coated glass 5 sq. roll ASTM D 2178 Type IV asphalt impregnated glass felt Page4 of41 mat base - sheet_ .ASTM D4601 Asphalt impregnated and coated, fiberglass base sheet ASTM D 2178 Type VI asphalt impregnated glass felt with asphalt coating. ASTM D 2178 Type VI asphalt impregnated glass felt with asphalt coating. with asphalt oatiag,__ 0o ing Product Contro Product GAFGLAS® Mineral Surfaced Ca • Sheet GAFGLAS® STRATA VENT® Perforated GAFGLAS® Flashing GAFGLAS® STRATAVENT Nailable RUBEROID Modified 3 sq. roll Base Sheet 67 lbs. GAFTEti1P® Isotherm R Tapered GAFTENIP® Isotherm R G.AFTE`IP Isotherm ' R.A Tapered GAFTEMP Isotherm RA GAFTEMP Isotherm RN Tapered GAFTEMP Isotherm RN GAFTEMP® Composite Test Dimensions SLecifica 60 Ib. roll 69 Ib. roll various various various various various various various 76 Ib. roll ASTM D 3909 various ASTM D 4897 D 3672 ASTM D 489 D 3672 PA 110 PA 110 PA 110 PA 110 PA 110 PA 110 PA 110 Page 5 of 41 Product Control No: 97- 0804,21 • Product Dcsc rt nth Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. Fiber glass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. Asphalt coated glass fiber mat flashing sheet available in three sizes. Fiber glass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. ASTM D460I, Premium glass fiber reinforced SBS- Type II, UL Type modified base sheet G2 BUR Polyisocyanurate foam insulation. Tapered Poly isocvanurate foam insulation Polyisocyanurate foam insulation Tapered Polyisocyanurate foam insulation Polyisocyanurate foam insulation Tapered Polyisocyanurate foam insulation Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insult 'a • -- • Roofing Product Control xam Note: All insulation shall be adhered to the anchor sheet in full moppings of approved hot asphalt within the EVT range and at a rate of 20- 401bsJs Please refer to Metro -Dade County Roofing Application Standard PA 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS STRATAVENT® perforated laid dry or a layer of GAFTEMP® PERMALITE or wood fiber overlay board on all isocyanurate applications. Anchor sheet: Base Sheet: (Optional) Install one ply of GAFGLAS® #75, GAFGLAS #80 Ultima' Ultra. Base Sheet, GAFGLAS STRATAVENT® Perforated or RUBEROID Modified Base Sheet directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq; (see General Limitation #4). Ply Sheet: Cap Sheet: Surfacing: GAFGLAS® Ply 4 ®, PIy 6 ®, GAFGLAS Flex PIyT" 6, #75 Base Sheet, GAFGLAS 480 UltimaT' Base Sheet, STRATAVENT® Nailable, RUBEROID Modified Base Sheet or RUBEROID® 20 base sheet applied to the deck with approved annular ring shank nails and tin caps at a' fastener spacing of 9" o.c. at the lap staggered in two rows 12" in the field. Base sheet shall serve as anchor sheet for attachment of insulation One, two, or three plies GAFGLAS PLY 4 ®, GAFGLAS® PLY 6® Ply or GAFGLAS Flex PIy 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet adhered in a full of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. (Required if no cap sheet is used) Install one of the following: 1. GAF Special Roofing Bitumen with an application rate of 20 lbs. /sq with an application rate of 1.5 gal. /sq.; or GAF WEATHER COATQ's Emulsion with an application rate of 3 gal. /sq.; or GAF Premium Fibered Aluminum Roof Coating with an application rate of 1.5 gal. /sq.. 2. Asphalt flood coat at an application rate of 60 Ibs.!sq. t 20 %; plus gravel or slag with an application rate of 400 lbs. /sq. & 300 lbs. /sq., respectively. Maximum Design Pressure: -45 psf (See General Limitation #7) Maximum Fire Classification: 'A'. See General Limitation #2. Maximum Slope: 3 ":12 "; See General Limitation #3. Page 19 of 41 Product Control No: 97- 0804.21 u loaga, Roofing Product Control Examiner Permit Number Roof Pitch Adhesive Type Tile Type TEST SUMMARY TEST RESULTS: PASSED_ See Attached Sketch for Further Details ROOF REPORTERS, INC. 4.0.1 z4 (561) 434 -7555 PA 106 -95 Roof Tile Uplift Test Report Test Date Sept. 11, 2000 Project Address 433 N.E. 91 St. Miami Shores, FI. Contractor H- & .H Remodeling. 47217 3:12 Tile Installation Date Sept. 8, 2000 Polyfoam Double Roll AU testing-is in strict accordance with The Dade- County version of The South Florida Building Code, Section 3401.10 and PA 106 -95. Each Test location was pulled using. a Chatillon Force- Gauge-to a minimum of 35 lbs.. Roof Area Total # of Tests # of Tests-Passed %Passed Field & Ridge 25 25 100% Corner 10 10 100% Perimeter 10 10 100% Dade County Certified Testing Agency # 94- 0916 -11 3281 Lake Worth RoadO Suite EO Lake WorthOFlorida 33461 Roof Consulting &_testing O Visual Surreys -& Evaluations ORoof System Design O Moisture Surveys T r i 'T r '4' T T 'T T r T ■o' 3g: T T T FI AT R1 F r - r T T Lk Kc, 9\ 57" T r T T -t T 'T T t SYNE1?GY Labs, Inc Manufacturer CHAT ILLON Model•- Number DFIS 100 Serial;Number 25282 • Customer .25282 Description DIGITAL FORCE GUAGE Customer: ROOF REPORTERS, i` INCORPORATED Certificate Number: 93158 Environmental Condition ;Temp: 21 deg C:: Relative humidity: 45% • This, certifies that the above . equipment was calibrated in compliance with the requirements of ANSI /NCSL -Z540- • 1994, ISO Guide 25, and :ISO 10012 using ' applicable procedures .: . At planned intervals, Synergy Labs,: Inc measurement standards are calibrated•by comparison to or measurement against national standards naturaf physical constants, consensus standards,` or by ratio type measurements using self - calibrating techniques:` National standards are administered by. NISI (National Institute of Standards and Technology) or other recognized national standards laboratories. Supporting documentation relative to traceability Is on file and is available for examination upon request Limits' " NONE Certificate of Calibration Remarks:. • UNIT. RECEIVED. IN TOLERANCE — NO ADJUSTMENTS- REQUIRED Calibration Date: •.Jurt 29, 2000 Calibration Due•:.. Sep 29, 2000 Reference Standards Used:. Serial Trace Model '." . Manufacturer Number Number Number . Calque Date AMETEK =M &G WG 23. 18830 74645 May 19, 2001 Synergy Labs, Inc 8211 NW 64;ST #3 Miami FL' Ph (305) - 477,5414 Josman Brizuala Quality Assura.ce