MECHANICAL PERMITBLDG. MIAMI SHORES VILLAGE BY | � � \ / � [L[CTRCAL \ _-'|--- PLUMBING M[CHAN / DATE SUBJECT TO COMPLIANCE WI1H ALL FEDERAL, STATE AND COUNTY RULES AND REGULATIONS• INSTALL G.F.I WATER PROOF OUT SIDE ELECTRIC RECEPTACLE WITH IN 20 FT. OF OUT SIDE UNIT • C/U 5 FT. FROM PROPERTY LINE 3' X 3' OPENING WINDOW 3' X 3' OPENING WINDOW FREON LINES / I UNDER HOUSE 3/4 - INSUL ATED P.V.0 DRAIN LINE 12 FROM WALL TO PERVIOUS GROUND IAA ecin . 1(4 BED RM. BATH RM. 8" X 4" 50 CFM 8" X 4" 50 CFM BATH RM. BED RM. 10" X 8" 200 CFM 8" 10" X 8" 200 CFM 10" X 10" R/A 8" 12" X 12" 4r R/A 10" X 10" R/A 24" X 8" 700 CFM 18 24 R/A GRILL AIR HANDLER DINNING RM LIVING RM. KITCHEN GARAGE HOUSE WALL 12" CONDENSING UNIT MOUNTING DETAIL A/C LNIT 4" SLAB AIR HANDLER MOUNTING DETAIL A/H STAND CLOSET SUPPLY DUCT AIR HANDLER FLOAT SWITCH RETURN AIR 2 #10 SCREWS PER STRAP INTO UNIT. 1 - ' /a x I- ' /a TAPCON INTO SLAB PER STRAP 2 GAUGE STEEL STRAP AT EACH CORNER OVER UNIT ON ALL 4 SIDES. ANCHORING OF UN]T WILL COMPLY WITH F.M.C. 301.13 TO WITHSTAND 1 0 MPH WINDS dr. A/C SLAB ELEVATED TO CROWN OF ROAD BALANCE RETURN .AIR ABOVE BED RVI DOORS DETAIL A/C CONTRACTOR: AAA MODERN AIR 901 PHIPPEN WAITERS RD. DANIA FL. 33004 PH. #954 - 921 -4486 FAX # 954 - 926 -5469 CMC470 MAKE: AMANA AIR HANDLER MODEL # CONDENSER MODEL # TOTAL BTU: NEW EQUIPMENT SPECIFICATIONS TONS: NAME: ADDRESS: CITY: JOB INFORMATION MINDES 354 NE 91 ST MIAMI SHORES ZIP: SEER: ARPT042 F.L.A F.L.A SENSIBLE BTU: RCC36A 3 5 / /cam 12 KW HEAT STRIP 35 18 M.C.A M.C.A 7.5 55 22 7 80 SCOPE OF WORK: NEW A/C AND DUCT SYSTEM. AS SHOWN 1) ALL EXISTING WALL & WINDOW A/C UNITS TO BE REMOVED. 2) NEW DUCT SYSTEM: R -6 FLEX AND R -6 DUCT BOARD. 3) ELECTRIC HOOK UP TO EXISTING 4) 1/2 "WALL INSULATION ON 7/8 200 3/8 AMP ELECTRIC SERVICE. FREON LINES WHERE SHOWN. 5) 1/2 " WALL INSULATION ON 3/4 " P.V.C. DRAIN LINE WHERE SHOWN DRAINING TO PERVIOUS GROUND. 6) INSTALL A FLOAT SWITCH INTO SECONDARY DRAIN OUTLET WIRED TO SHUT DOWN A/C SYSTEM. PER. F.M.C. M307.2.3 7) INSTALL G.F.I WATER PROOF OUT SIDE ELECTRIC RECEPTACLE WITH IN 20 FT. OF OUT SIDE UNIT. 901 PHIPPEN RD, DANIA, FL Phone: 922 -4347 Pro'ect Information Outside db Inside db Design TD Building heat loss Ventilation air Ventilation air loss Design heat load Efficiency Heating Input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat For: Notes: Project Summary Entire House AAA MODERN AIR Desi • n Information Weather: Winter Design Conditions Method Construction quality Fireplaces Area (ft') Volume (ft Air changes /hour Equiv. AVF (cfm) Heating Equi Make AMANA Trade AMANA Model ARPT042 7. Heating Summary Infiltration MINDES M t A Wtf 3I r v' 354 NE 91 ST.. 46 °F 70 °F 24 °F 15170 Btuh 27 cfm 708 Btuh 15878 Btuh Simplified Average 0 Heating Cooling g 550 580 5800 5800 1.05 0.55 101 53 pment Summary 5 KW HEAT STRIP 80 AFUE 0 Btuh 0 Btuh 0 °F 1200 cfm 0.079 cfm /Btuh 0.45 in H2O wrightsoft Right -Suite Residential J8 5.8.24 RSR25416 Fort Lauderdale, FL, US Outside db Inside db Design TD Daily range Relative humidity Moisture difference Job: Date: By: Summer Design Conditions 91 °F 75 °F 16 °F L 50 % 60 gr /Ib Sensible Cooling Equipment Load Sizing Structure Ventilation Design temperature swing Use mfg. data Rate /swing multiplier Total sens. equip. load Latent Cooling Equipment Load Sizing Internal gains Ventilation Infiltration Total latent equip. load Total equipment load Req. total capacity at 0.70 SHR Cooling Equipment Summary Make AMANA Trade AMANA Cond RCC362A Coil ARPT042 Efficiency 12 SEER Sensible cooling 24780 Btuh Latent cooling 10620 Btuh Total cooling 35400 Btuh Actual air flow 1200 cfm Air flow factor 0.050 cfm /Btuh Static pressure 0.00 in H2O Load sensible heat ratio 85 % Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 24137 Btuh 472 Btuh 3.0 °F n 0.96 23624 Btuh 800 Btuh 1091 Btuh 2161 Btuh 4392 Btuh 28016 Btuh 2.8 ton 2004 - Nov -01 19:09:42 f1CCK C:\Documents and Settings \USER \My Documents\right - j \3TAMA5SUP.rrp Calc = MJ8 Orientation = N Page 1 ROOM NAME Area (ft Htg Toad (Btuh) CIg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) BED RM1 120 4441 6934 351 345 BED RM 2 130 3963 6601 313 328 LIVING RM 375 3635 5248 288 261 BATH RM2 64 2443 4315 193 215 BATH RM 36 687 1038 54 52 Entire House d 725 15170 24137 1200 1200 Ventilation air 708 472 Equip. @ 0.96 RSM 23624 Latent cooling 4392 T(1TAI C 7')G 4 co70 none", ..NINA, ....... 901 PHIPPEN RD, DANIA, FL Phone: 922 -4347 Make Trade Model Outside db ( °F) Inside db ( °F) Design TD ( °F) Daily range Inside humidity ( %) Moisture difference (gr /Ib) Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Short Form Entire House AAA MODERN AIR Project Information For: MINDES 354 NE 91 ST., FT. LAUD., FL Design Information Htg 46 70 24 HEATING EQUIPMENT AMANA AMANA ARPT042 7.5 KW HEAT STRIP 80 AFUE 0 0 0 1200 0.079 0.45 CIg 91 75 16 L 50 60 Btuh Btuh °F cfm cfm /Btu h in H2O Method Construction quality Fireplaces Make AMANA Trade AMANA Cond RCC362A Coil ARPT042 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio wrughltsoft Right -Suite Residential J8 5.8.24 RSR25416 ,4CCA C:1Documents and Settings \USER \My Documents\right - j13TAMA5SUP.rrp Calc = MJ8 Orientation = N Infiltration Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Job: Date: By: COOLING EQUIPMENT 12 SEER 24780 Btuh 10620 Btuh 35400 Btuh 1200 cfm 0.050 cfm /Btuh 0.00 in H2O 85 % Simplified Average 0 2004- Nov -01 19:09:42 Page 1 901 PHIPPEN RD, DANIA, FL Phone: 2 -4347 w rog hit so Right -Suite Residential J8 5.8.24 RSR25416 ACCA C: \Documents and Settings \USER \My Documents\right - j \3TAMA5SUP.rrp Calc = MJ8 Orientation = N Right -J8 Worksheet Entire House AAA MODERN AIR Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Job: Date: By: 2004 - Nov -01 19:09:42 Page 1 Room name Exposed wall Ceiling height Room dimensions Room area Entire House 82.0 ft 8.0 ft d 725.0 ft' BED RM1 22.0 ft 8.0 ft heat/cool 12.0 x 10.0 ft 120.0 ft' Ty Construction number U -value tuh /ft' - °F) Or HTM (Btuh /ft') Area ft') or perimeter (ft) Load (Btuh) Area ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N /P /S Heat Cool Gross N /P /S Heat Cool 6 ,13B 0ocw. , 0:103; 2:47 1 67, 565 484' 1198 808 1,99` ] 181r 447 302- 0A`c1 ' 1,1'D0. "` ` � 1 :27(i '039011 3048 '9:36 3604 1170 X45, s " 36 " 0 .36; ;,' . 1372 • 337. 1622 ` 421, ..18€ ^ 0 0 ` 0 549 - A,,, 649` <" _ ' "0 . 13AA -Ooc 0.5841 14.02 12.21 9 -119 -1668 -1452 9 -27 -378 -330 11 1A -clom 1,270 30.48 92.39 128 0 3901 11826 36 0 1097 3326 13'0'0 =0oc 0 584'• 14:02 12-2 '.?4'.. 1430 "71: .- 4 . 5 0 36 505 ,439; 1A clout 1;270` 30:48 .39:15 , 126 `. "1 ' " ' 4933; ; : 36` T0 11'097 1409, 16B -11ad 0.081 1.94 3.52 725 725 1409 2555 120 120 233 423 22A -vph' - - X1;58' , - 32>59 ' 0:00 '° =' '. 69'0 • '82 :; .'2673 , • , 0' `- 120= " 22 . 117 "`"`0 Envelope loss /gain 11631 19466 3258 5340 12 a) Infiltration 2680 936 932 325 b) Ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 2 460 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 14311 21322 4190 6125 15 Duct loads 6% 13% 859 2815 6% 13% 251 809 Total room load 15170 24137 4441 6934 Air required (cfm) 1200 1200 351 345 901 PHIPPEN RD, DANIA, FL Phone: 2 -4347 w rog hit so Right -Suite Residential J8 5.8.24 RSR25416 ACCA C: \Documents and Settings \USER \My Documents\right - j \3TAMA5SUP.rrp Calc = MJ8 Orientation = N Right -J8 Worksheet Entire House AAA MODERN AIR Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Job: Date: By: 2004 - Nov -01 19:09:42 Page 1 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area BED RM 2 23.0 ft 8.0 ft heat/cool 13.0 x 10.0 ft 130.0 ft' LIVING RM 25.0 ft 8.0 ft heat/cool 25.0 x 15.0 ft 375.0 ft' Ty Construction number J -value (Btuh/ft'-°F) Or HTM (Btuh /ft') Area ft') or perimeter (ft) Load (Btuh) Area ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N /P /S Heat Cool Gross N /P /S Heat Coot 6 .1313A09nw 0:103' i CC CN dtpN 2:47 1167 1661 '9' 130 336i 227; 11:7 117 - 2130 195 1A- cloth 1.270? 30 :48 36:04 0 274' 324' 0 - , 0 "0 '0 1900 0.390' 9.36 11.70 21' 21 197 246: 0 0 . .0 0 13AA -0oc 0.584 14.02 12.21 0 -36 -505 -439 0 -25 -350 -305 11 1A -clom 1.270 30.48 92.39 36 0 1097 3326 25 0 762 2310 1A omc .1.270; 30'48 39(15 36' -36, 0 1097+ 140 9 30 20 '0 294 91`4_ - 1'174` 16B -11ad 0.081 1.94 3.52 130 130 253 458 375 375 729 1321 1 ".. _ =t , i22A =vph 1:358 3239 ' 000 130 23'' 750 0 375 . '25 615 ' '" ` Envelope loss /gain 2995 5112 2865 4439 12 a) Infiltration b) Ventilation 744 0 260 0 565 0 197 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 15 Subtotal Duct loads 3739 5831 3429 4636 6% 13% 224 770 6% 13% 206 612 Total room load 3963 6601 3635 5248 Air required (cfm) 313 328 288 261 901 PHIPPEN RD, DANIA, FL Phone: 922 -4347 Right -J8 Worksheet Entire House AAA MODERN AIR Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrug htsc - F& Right -Suite Residential J8 5.8.24 RSR25416 .4CC C: \Documents and Settings \USER \My Documents\right - j \3TAMA5SUP.rrp Calc = MJB Orientation = N Job: Date: By: 2004- Nov -01 19:09:42 Page 2 I •— CN1 Nt Lt, Room name Exposed wall Ceiling height Room dimensions Room area BATH RM2 8.0 ft 8.0 ft heat/cool 8.0 x 8.0 ft 64.0 W BATH RM 4.0 ft 8.0 ft heat/cool 4.0 x 9.0 ft 36.0 ft' Ty Construction number U-value (Btuh/W-T) Or HTM (Btuh/ft') Area ft) or perimeter (ft) Load (Btuh) Area ft) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S He Cool Gross N/P/S Heat Cool 6 . 11 ] :113BA=00,01 j146101:0''' 1 , 13AA-Ooc 1A-c1om 13AA 1A-biii 16B-11ad 12gliPti ', "': , 004: , .'" ', - - a661 0.584 1.270 0594) 1.270 0.081 1.3581 . . , :!' c i' , . Ii:',;,?3048 14.02 30.48 '14:0 30:48 1.94 3259 . '...::: 197 I':::: t36:M lillo 12.21 92.39 1241: 3915 3.52 000 , . ;,:' ' :,,,' '; .. , -'.1t", 0 25 ' '9'; 18: 64 64 " '30 , . 0 •.-.:--. !-, :161 -25 0 , 4 0: 64 :8: :::'.: ;',. '' ,' ‘. , -. ' ,. ' 146 -350 762 LI16 849 124 261' ' ,' : , 150! ''''' . ' -305 2310 . . , •;f16 :'1& 226 o : itirc:77,0 0 CD `(.0 (1) ' ' e,,. :, .,.- -6 0 ," - ',- , 15 . :o 36 4 „ . , ' :., , . , ..„ ''' 49 - -84 183 „r. o , - 1.0 70 130 .. -.'•, : -73 554 r: ', % ... , ::, 235: 127 ' ''a , . • . • • Envelope loss/gain 1982 3699 531 876 12 a) Infiltration b) Ventilation 323 0 113 0 117 0 41 0 13 14 15 Internal gains: Less external load Less transfer Redistribution Subtotal Duct loads Occupants @ 230 Appliances @ 1200 0 0 6% 13% 0 0 0 2305 138 0 0 0 0 0 3812 503 0 0 6% 13% 0 0 0 648 39 0 0 0 0 0 917 121 Total room load Air required (cfm) 2443 193 4315 215 687 54 1038 52 901 PHIPPEN RD, DANIA, FL Phone: 922-4347 Right-J8 Worksheet Entire House AAA MODERN AIR Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrig t so Right-Suite Residential J8 5.8.24 RSR25416 ACCA C:\Documents and Settings \USER \My Documents\right - j\3TAMA5SUP.rrp Calc = MJ8 Orientation = N Job: Date: By: 2004-Nov-01 19:09:42 Page 3 Miami Shores Village 10050 NE 2nd Avenue Phone: 305 - 795 -2204 Printed: 11/24/2004 Applicant: PAULINE Owner: MINDES JOB ADDRESS: 354 Contractor AAA MODERN AIR INC Local Phone: 954 - 921 - 4486 Parcel # 1132060190220 NE 91 Signed: (Contractor or Builder) Mechanical Permit Permit Number: MC2004 -205 MINDES PAULINE ST Page 1 of 1 Contractor's Address: 901 PHIPPEN WATTERS RD Legal Description: EL PORTAL Permit Status: APPROVED Permit Expiration: 5/17/2005 Construction Value: $3,550.00 Work: NEW A/C DUCT AS PER PLANS PB 9 -101 LOT 6 & W1/2 LOT 5 BLK 2 LOT SIZE 75.000 X 135 Fees: FEE2004 -11715 FEE2004 -1 1 71 6 FEE2004 -11717 FEE2004 -11718 FEE2004 -11719 FEE2004 -11720 Description Building Fee CCF Training and Education Fee Technology Fee Scanning Fee Submittal Fee Total Fees: Amount $124.25 $2.40 $0.80 $3.11 $6.00 ($50.00) $86.56 Total Fees: $86.56 Total Receipts: $0.00 4 D I do Signed: (INSPECTOR) In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responisibility for all work done by either myself, my agent, servants or employes. BY: l oAlt q.40A4 FBC 2001 Miami Shores Village ling D epartment nd Avenue, Miami Shores, Florida 33138 Job Address (where the work is being done) 3SLf E t S ) 756.8972 Permit No. 1 Cc 1 - 20S Master Permit No. Permit Type (circle): Building Electrical Plumbing Mechanical Roofing Owner's Name (Fee Simple Titleholder)bo"V t V r' 64E /20 Phone # d S 3 2Cc l / Owner's Address 354 /U / ' g City /A Sifo/'fs State roe) Zip 3 3) 3 Tenant/Lessee Name Phone # 30537E GO/ City Miami Shores Village County Miami -Dade Zip 3 3 1 3 e Is Building Historically Designated YES NO X" Contractor's Company Name All* M 1, S Contractor's Address 9D/ Ph ie1) City 6 1 /P' State F Qualifier / Ito/e/ d9- Architect/Engineer's Name (if applicab $ Value of Work For this Per Type of Work: ❑Addition ❑Alte ation Describe Work: ,t/& i { 4 i. e Total Fee Now Due $ (Continued on opposite side) ❑New Phone # Phone # Square Footage Of Work: ❑ Repair/Replace ❑ Demolition 9f4 Q2/ 'i41p Zip 3b1 * * * * * * * * * * * * * * * * * * * * * * * * * ** ee * * ** * * * * * * * * * * * * * * * * * * * * * * * ** Submittal Fee $ SO 06 Permit Fee $ CCF $ 1 t i ° CO /CC '- 1 / n Notary $ �� Training/Education Fee $ l�/ ° Technology Fee $ g . 1/ Scanning $ • Radon $ Zoning Bond $ Code Enforcement $ Structural Plan Review. $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approve nd a reinspection fee will be charged. 1 ./ Signa NOTARY PUBLIC: Owner or g� Contractor / The foregoing instrument was acknowledged before this The foregoing instrument was cknowledged before me this !/ day of l , 20 b`(, by ' DOW aw ld V ► 1 ovi G >�C,a day of 1 C , 2 b ( (� (I /c) d , who is personally known t fre s h e As identification and who did take an oath. Signature as identification and who did take an oath. NOTARY PUBLIC: Sign: �i�/ ✓ . i .. Sign: t'✓1 Print: Amy Jane taycock Print: ' , •, = MY COMMI SION # DD008864 EXPIRES r•= MCI 17 2005 * * * * * * * * * * * * * * * * * * * * * * * *. *ar * *IiN'�i;rU'4iMdS �` F�! i�6153' U#k f1C` Ew************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** (Certificate of Competency Holder) State Certificate or Registration Non / P1 33-3 Certificate of Competency No. - My Commission Expires: My Commission Expires: *************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * * * * * * * * * * * * * * * ** * * * * * ** *** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** APPLICATION APPROVED BY: Plans Examiner k_ Chc 12/15/03 SION # DD008864 EXPIRES May 17, 2005 THU TROV FAIN INSURANCE. IN. Engineer Zoning Date��_.��� Tyne Insp'n Permit No. C 1-jeiap-4- Address 554 NE, cr L S Company Tripe a ! Inspectior- Dat2. l !� Appro icd Co .ection Ke-iTu p n Fee MJA .SI4OR.ES VI = .Air- -- BUILDING DEPARTMENT 305 -795 -2204 Insp ction v i