MECHANICAL PERMITa SELECTION BASED D Pi/C DESIGNATION E SIGNA HON MODEL NO. SEIECBON PASEO ONp, _ M MODEL NUMBER g4/44 0314 PL[NUM SUCTION LINE. _IOU10 LINE CONDENSATE ,o.S HEATER 7 Tk $ 4L /oK W COMPRESSOR DATA RLA. CFM SUPPLY /2 LRA FAN DATA NP ?o t Y3 CFM O.A. 0 AIR HANDLING UNIT .. SCHEDULE CONDENSING UNIT SCHEDULE. FAN • 01Q TOR EX T. S.P IN. W.C. , / 11P P. AMPS 611CI_NCY SEER /2 ' f AN A10TOR 'CO? CAPACI nES (Neu) COOLING HEATING TOTAL SENS. TO TAI 35, c .25 /vo 3y/v0 ELECTRICAL DATA vGI.TS PHASE AMPS MOCP 2.PYI1. 35" - WT (Les) ik0 STRIP 'EATE'R K.W. 1 STEPS io : ELECTRICAL DMA VOLTS PHASE 20£jl AmP WT. MOCP (l8S 7 0 A WINTER DESIGN CONDITIONS Outside db: Inside db: Design TD: For: By: HEATING SUMMARY Bldg. Heat Loss Ventilation Air Vent Air Loss Design Heat Load INFILTRATION Const Qual a # Fireplaces 0 HEATING Area (s .ft.) 1192 Volume (cu.ft.) 9536 Air Changes /Hour 1.0 Equivalent CFM 159 RIGHT -J LOAD AND EQUIPMENT SUMMARY JONES 32 NE 91 STREET MIAMI SHORES FL TEMP CONDITIONING SERVICE, INC. PO BOX 557054 MIAMI FL 47 Deg F 70 Deg F 23 Deg F 34497 Btuh 0 CFM 0 Btuh 34497 Btuh COOLING 1192 9536 0.5 HEATING EQUIPMENT SUMMARY Make RHEEM Model RBEA17J10SUFAI Type A/H 10 KW Efficiency / HSPF 0.0 Heating Input 0 Btuh Heating Output, 0 Btuh Heating Temp Rise 0 Deg F Actual Heating Fan 1200 CFM Htg Air Flow Factor 0.035 CFM /Btuh Space Thermostat Job #: Wthr : Miami_AP_(S) Zone : SUMMER DESIGN CONDITIONS Outside db: Inside db: Design TD: Daily Range Rel. Hum. . Grains Water SENSIBLE COOLING EQUIP LOAD SIZING Structure 25763 Btuh Ventilation 0 Btuh Design Temp. Swing 3.0 Deg F Use Mfg. Data n Rate /Swing Mult. 0.95 Total Sens Equip Load 24475 Btuh LATENT COOLING EQUIP LOAD SIZING Internal Gains Ventilation Infiltration Tot Latent Equip Load Load Sens Heat Ratio 5 -14 -98 90 Deg F 78 Deg F 12 Deg F 50 % 56 gr 920 Btuh 0 Btuh 3032 Btuh 3952 Btuh Total Equip Load . 28427 Btuh COOLING EQUIPMENT SUMMARY Make RHEEM Model RAMA036JAZ Type COND COP /EER /SEER Sensible Cooling Latent Cooling Total Cooling Actual Cooling Fan Clg Air Flow Factor 12.4 25100 35600 1200 0.047 87 MANUAL J: 7th Ed. RIGHT -J: V1.72 S/N 2980 Printout certified by ACCA to meet all requirements of Manual Form J FL Btuh Btuh Btuh CFM CFM /Btuh RIGHT -J CALCULATION PROCEDURES A,B,C,D Job #: 5 -14 -98 Procedure A - Winter Infiltration HTM Calculation* 1. Winter Infiltration CFM 1.0 AC /HR x 9536 Cu.Ft. x 0.0167 2. Winter Infiltration Btuh 4.1 x 159 CFM x 23 Winter TD = 3. Winter Infiltration HTM 4029 Btuh / 241 Total Window = & Door Area Procedure B - Summer Infiltration HTM Calculation* 1. Summer Infiltration CFM 0.5 AC /HR x 9536 Cu.Ft. x 0.0167 2. Summer Infiltration Btuh 1.'1 x 80 CFM x 12 Summer TD = 3. Summer Infiltration HTM 1051 Btuh / 241 Total Window = & Door Area Procedure C - Latent Infiltration Gain 0.68 x Procedure D - Equipment Sizing Loads 159 CFM 4029 Btuh 16.7 HTM 80 CFM 1051 Btuh 4.4 HTM 56 gr.diff. x 80 CFM = 3032 Btuh 1. Sensible Sizing Load Sensible Ventilation Load 1.1 x 0 Vent.CFM x 12 Summer TD = 0 Btuh Sensible Load for Structure (Line 19) + 25763 Btuh Sum of Ventilation and Structure Loads = 25763 Btuh Rating and Temperature Swing Multiplie x 0.95 RSM Equipment Sizing Load - Sensible + 24475 Btuh 2. Latent Sizing Load Latent Ventilation Load 0.68 x 0 Vent.CFM x 56 gr.diff. = 0 Btuh Internal Loads = 230 x 4 No. People + 920 Btuh Infiltration Load From Procedure C + 3032 Btuh Equipment Sizing Load - Latent = 3952 Btuh *Construction Quality is: a No. of Fireplaces is: 0 MANUAL J: 7th Ed. RIGHT -J: V1.72 S/N 2980 Printout certified by ACCA to meet all requirements of Manual Form J Job #: Zone: 5 -14 -98 MANUAL J: 7th Ed. - - -- RIGHT -J: V1.72 - - -- S/N 2980 - -- Page 1 - - -- 1: Name of Room Entire House LIVING ROOM 2 Running Ft. Exposed Wall 155.0 Ft. 18.0 Ft. 3 Room Dimensions, Ft. 18.0 x 13.0 Ft. 4; Ceilngs,Ft ; Condit. Option 8.0 ; 8.0 ; heat /cool TYPE OF � 'CST' ' HT Area : Btuh EXPOSURE , ,NO.,Htg ,Clg ,Length, Htg Clg 5' Gross Exposed Walls and Partitions 6' Windows & Glass Doors Htg. 7' Windows & Glass Doors Clg. TYPE OF EXPOSURE lb;14B' 0 0' 0.0 d ' 0 0.0 e! 0.0, 0.0 ,f, , 0.0, 0.0 'a ** 'b t 1C t 26.6 ; ** c I d' iC 20.0' ** h et 1 0.0 ** ,f, , 0.0, ** ' North NE &NW E&W SE &SW South Horz 1 0.0 4 0. 0 24.0 , 0.0 8' Othr doors :a:10D'10.6' 7.2 ,b, , 0.0, 0.0 9' Net Exposed Walls and c' ' 0.0 Partitions d" lal14B; 3.3' 1.2 0.0 0.0 0.0 0.0 10 Ceilings laa'16A'130.01 0.2 0 c; ; 0.0; 0.0 11 Floors Ia 0.0 1 0.0 c; ; 0.0; 0.0 12: Infiltration a ;16.7; 4.4 13Subtot Btuh Loss= 6 +8.. +11 +12 14 Duct Btuh Loss 15, Total Btuh Loss = 13 +14 5' Gross 'a'14B' 3.3' 1.2' ' Exposed ' ' 0.0 0.0' W and c 0 0.0' Partitions I dl � 0.0� 0.0� I l e ' 00� 0.0� 0..0, 0.0, 1240` ' * * ** ' * * ** O 1 : * * ** 0 * * ** * * ** O : * * ** : * * ** O t * * ** t * * ** 0; * * ** * * ** 101' 2683` ; * * ** 84 2231 * * ** 35 93 * * ** 0 * * ** 0, * * ** 0, * * ** O ` O , 60' * * ** ' 840 O t * * ** : 0 65 * * ** ' 3120 O : * * ** 95 * * ** ; 2280 21' O , 222' 151 0, 1118: 3703' 1336 • t l • l t 01 t 0, ' 0 O ; 0 0 1192' 16422' 1 4585 0; 0; 0 1192' 4277 0; 0 * * ** ' 34497' * * ** 0 %' 0 * * ** * * ** 34497; * * ** ' 'CST' HTM Area ' Btuh NO. ;Clg ;Length; Htg ; Clg 0' * * ** ' * * ** 0 * * ** : * * ** 0 * * ** * * ** 0 * * ** * * ** 0: * * ** t * * ** 0: * * ** * * ** 0 0 241: 4029: 1051 Area ' Btuh Length; Htg Clg 144` * * ** ' * * ** 0' * * ** t * * ** O * * ** t * * ** O 1 * * ** 1 * * ** O 1 * * ** 1 * * ** 0, * * ** * * ** 3 0' O ' 0' O ' 0! 36' * * ** O 1 * * ** 0 1 * * ** O ' * * ** O * * ** O ; * * ** 21' 0, 8 0 ; O ' 0' O ' O ' 234 0' 956' * * ** 0' * * ** O t * * ** 01 * * ** 0! * * ** O : * * ** 222' 151 O , 288' 0 ' of 0' O ; 840 0' Area ' Btuh Length; Htg Clg 504 0 0 0 0 104 0 0 0 0 234' 3224' 2 863 0; 0; 0 57; 953; 249 * * ** 6483` * * ** 0 %' 0 ; * * ** * * ** 6483: * * ** 192' * * ** ' * * ** 0' * * ** : * * ** 0 * * ** * * ** 0 ' * * ** 1 * * ** 0: * * ** * * ** 0 * * ** * * ** 0 0 16' Int. Gains: People @ 300 4' * * ** ' 1200 4 * * ** ' 1200 ' ' Appl @ 1200 1 * * ** ' 1200 0 * * ** t 0 17 ( Subtot RSH Gain= 7 +8.. +12 +16 * * ** 1 * * ** 25763 * * ** t * * ** ' 5070 18 Duct Btuh Gain 0 % ; * * ** 0 0 % ' * * ** 0 19 Total RSH Gain = 17 +18 * * ** t * * ** 25763 * * ** 1 t 5070 ,20, CFM Air Required , * * ** , 1200, 1200, * * ** : 226; 236, - -- Printout certified by ACCA to meet all requirements of Manual Form J -- Job #: Zone: 5 -14 -98 MANUAL J: 7th Ed. - - -- RIGHT -J: V1.72 - - -- S/N 2980 - -- Page 2 - - -- 1' Name of Room DINING ROOM KITCHEN 2� Running Ft. Exposed Wall ' 0.0 Ft. 24.0 Ft. 3, Room Dimensions, Ft. 18.0 � : x 12.0 Ft. 12.0�x 12.0 Ft. : 4, Ceilngs,Ft : Condit. Option, 8. heat /cool 8.0 heat /cool • 6' Windows 'a' 1C'26.6' ** & Glass �b� 1 0 26 Doors Htg. c, 1C,26.6 d , 0.0 7' Windows & Glass Doors Clg. 8' Othr doors :a:10D'10.6: 7.2 ,b, , 0.0, 0.0 9' Net 'a'14B' 1 3.3 1.2 Exposed I b: . 0 0 0.0 Walls and I c 1 00 0.0 Partitions ,d, 1 0.0, 0.0 � � 0.0 0.0 if! , , 0. 0, 0. 10' Ceilings 'a'16A � , � b � � 0.0� 0.0 c, , 0.0, 0.0 11; Floors 12: Infiltration 13Subtot Btuh Loss= 6 +8.. +11 +12 14 Duct Btuh Loss 15, Total Btuh Loss = 13 +14 16' Int. Gains: People @ 300 0' * * ** ' 0 0' * * ** ' 0 � Appl @ 1200 0� * * ** 0 1� * * ** 1200 17 Subtot RSH Gain= 7 +8.. +12 +16 * * ** * * ** 2643 * * ** * * ** 3907 18 D Bt G 0 % * * ** 1 0 0 % 1 * * ** 1 0 191 1 * * ** 1 2643 Total RSH Gain = 17 +18 * * ** * * ** 1 1 3907 ,20, CFM Air Required , * * ** , 130, 123, * * ** ; 135, 182, - -- Printout certified by ACCA to meet all requirements of Manual Form J -- Job #: Zone: 5 -14 -98 MANUAL J: 7th Ed. - - -- RIGHT -J: V1.72 - - -- S/N 2980 - -- Page 3 - - -- ` 1; Name of Room FAMILY ROOM BEDROOM 1 2 Running Ft. Exposed Wall 40.0 Ft. 26.0 Ft. 3 Room Dimensions, Ft. 18.0 x 11.0 Ft. 12.0 x 14.0 Ft. 4; Ceilngs,Ft ; Condit. Option; 8.0 ; heat /cool 8.0 ; heat /cool TYPE OF EXPOSURE Exposed Walls and 1 Partitions 6' Windows & Glass 1 Doors Htg. ** ** ** ., 0 ' ** f! ; 0.0, ** ' North NE &NW E &W SE &SW South , Horz �b19A � � 3.6' 0.0 c ; 0.0, 0.0 ' `CST' HTM ' Area ' Btuh NO .�Htg ;Clg ;Length; Htg ; Clg 5; Gross ;a;14B; 3.3; 1.2 d 1 f1 b1 1C �c, 1C d, t f, 7' Windows ' North & Glass NE &NW Doors Clg. E &W SE &SW South , Horz 1 0.0 4 0.0 24.0 , 0.0 a :16.7: 4.4 1 0 0 0.0 0 0.0 0.0; 0.0 1C'26.6' ** 26.6 ** 26.6 ** 0.0 ** 1 0.0 ** 0.0; ** 14.0 0.0 48.0 0.0 24.0 0.0 8; Othr doors ;a;10D;10.6; 7.2 0' 0, 0 0 , 0 0 0' ; 0' 1 0 0, 0' 0 0� 0 0 1 21 297 264 0; 0; 0 216' 0 0; 0' 0 * * ** ' 3751' * * ** 0 % 0 * * ** * * ** ; 3751! * * ** 320' * * ** 1 * * ** 0 * * ** * * ** 0 * * ** * * ** 01 * * ** * * ** 01 * * ** 1 * * ** p: * * ** 1 * * ** 35 3 0► 0 0 0' 0! 0� 0 0 1 775 0 425; * * ** 930 0 0 0 0 0 0 0 0 0 0 768 1680 0: 0: o, 9' 239; * * ** 0: 2300 0 1 0 0 , O , O ' 0 0 0 432 216 0 0' 0 0; 183' 60 219 O 1 0 0 O i 0� 0 0, 0 144' 1984' 1762 O ; 0; 0 144' 0 I 51 70 0 I 18; 301; 79 * * ** ' 3886' * * ** *** * * � %; 3886; * * ** Area ` Btuh Length; Htg Clg 208' * * ** ' * * ** 0 * * ** 1 * * ** 0 * * ** 1 * * ** 0 * * ** 1 * * ** 0 * * ** * * ** p� * * ** * * ** 16' 16 0 0 0 0 0 0 0 768 384 0; 0, 9' Net 'a'14B` 3.3' 1.2 1 Exposed a s an ,cb 1 0 0 0.0 1 Wlld !t ! 0.0 0.0 1 Partitions t d 00� 0.0 t t t 0. 0.0 , ,f, 0.0, 0.0 ibi i 0.0; 0.0 10' Ceilings Ia c, 0.0, 0.0 11' Floors 'a 3 0.0 c; 0.0, 0.0 12; Infiltration a ;16.7; 4.4 13'Subtot Btuh Loss= 6 +8.. +11 +12 14, Btuh Loss 15, Total Btuh Loss = 13 +14 16' Int. Gains: People @ 300 0` * * ** ' 0 0' * * ** ' 0 I Appl. @ 1200 0 * * ** t 0 0 1 * * ** 1 0 17 Subtot RSH Gain= 7 +8.. +12 +16 * * ** 1 * * ** 1 5609 * * ** 1 * * ** 1 3577 18 Duct Btuh Gain 0 % * * ** 1 0 0 % t * * ** t 19 Total RSH Gain = 17 +18 * * ** t * * ** 1 5609 * * ** t * * ** 1 3570 ,20 CFM Air Requir * * ** , 284, 261 * * ** 1 172, - -- Printout certified by ACCA to meet all requirements of Manual Form J Job #: Zone: 5 -14 -98 MANUAL J: 7th Ed. - - -- RIGHT -J: V1.72 - - -- S/N 2980 - -- Page 4 - - -- 1: Name of Room BATH 1 BATH 2 2 Running Ft. Exposed Wall 5.0 Ft. 6.0 Ft. 3 Room Dimensions, Ft. 8.0 � , x 5.0 Ft. 8.0�x 6.0 Ft. , 4, Ceilngs,Ft , Condit. Option, 8. heat /cool 8.0 heat /cool TYPE OF EXPOSURE � 'CST' HTM Area Btuh !NO.,Htg :Clg ,Length, Htg , Clg 5' Gross 'a'14B' 3.3' 1.2 Exposed b . 0 0 0.0 Walls and c 00 0.0 Partitions i d s � 0.0 0.0 l 0.01 0.0 ,f, , 0.0, 0.0 6' Windows 'a' 1C'26.6' ** & Glass ' b ' 1C ** ' Doors Htg. ' c 1C26.6 ** I I 0.0 ** l e l 00 ** f, , 0.0, ** 7' Windows ' North '14.0 ' & Glass 1 NE &NW ' 0.0 ' Doors Clg. 1 E &W 1 48.0 I I SE &SW � 0.0 I I South 1 24.0 , Horz , 0.0 8 Othr doors :a:10D 7.2 ,b, 0.0, 0.0 9' Net 'a'14B 3.3' 1.2 Exposed b ' 0.0 0.0 Walls and c ' 0 0.0 Partitions d 0.0 0.0 e! 0.0 0.0 ,f, , 0.0, 0.0 10' Ceilings 'a'16A'13.8'12.2 ' 'b ' 0 0' 0.0 0.0, 0.0 11' Floors 'a'19A' 3.6' 0.0 I Ibl 1 0.0 0.0 , ,c, 0.0, 0.0 30 1007' 363 O l l • t l 0 0 0 1 O 1 l 0! Ol 0 0, 198' 2728' 2 423 O ! 0! 0 198' 0! 86: 1438: 375 * * ** ' 8167' * * ** 0 % 0 1 * * ** * * ** , 8167, * * ** 40' * * ** ' * * ** 0 * * ** 1 * * ** 0 * * ** * * ** 0 * * ** * * ** 0 * * ** * * ** O 1 * * ** 1 * * ** 4' 106' * * ** O 0' * * ** O ' 0 ' * * ** O 1 0 1 * * ** 0 0 * * ** 0 0 * * ** 0' 0! 0 ' 0 0 36' 11 43 0 0 0 I I I I 0 0 0 0 , 0, 40' 0; 0; 0' 0; 0; 0` 0 0 ' 710 0 0! 0 55 0 0 192 0 0 489 0 40� 144' 0 0; 0; 0, 192: 636' 2 29 O 1 0 0 l 01 01 0 0, 0 168 2315 205 O ! 0, 0 168' 603' 0 0; 0! 0 32: 535; 140 * * ** 4938' * * ** 0 % ! 0 * * ** * * ** 4938, * * ** Area ' Btuh Length; Htg ; Clg 48' * * ** ' * * ** 0 * * ** * * ** 0 * * ** * * ** 0 * * ** * * ** 0 * * ** 1 * * ** 0; * * ** ; * * ** 4 4' 106' * * ** 01 0 * * ** 1 1 * * ** 0 0 1 1 * * ** 0 0 1 0 � * * ** 0 * * ** 0' * * ** ' 0 0 * * ** 1 0 4 * * ** i 192 0 * * ** ' 0 * * ** ' 0 * * ** ; 0 0' ! 0 ' 0 0, 4 14 53 0 0 0 0 I I I I 0 0 0 0 0 0, 0, 0 48' 661' 587 0 ! 01 ' 0 0, 4 172' 0 0 0! 0; 0, '12; Infiltration a :16.7: 4.4 13'Subtot Btuh Loss= 6 +8.. +11 +12 14, Duct Btuh Loss 15; Total Btuh Loss = 13 +14 16' Int. Gains: People @ 300 0' * * ** 0 0' * * ** ' 0 1 Appl. @ 1200 0 1 * * ** t 0 0 1 * * ** t 17 Subtot RSH Gain= 7 +8.. +12 +16 * * ** 1 * * ** ! 742 * * ** 1 * * ** 1 849 18 Duct Btuh Gain 0 % * * ** 1 0 0 % ! * * ** 19 Total RSH Gain = 17 +18 * * ** 1 * * ** t 742 * * ** t * * ** 1 0 849 ,20; CFM Air Required , * * ** , 34, 35, * * ** : 40, 40 - -- Printout certified by ACCA to meet all requirements of Manual Form J -- Job #: Zone: 5 -14 -98 } MANUAL J: 7th Ed. - - -- RIGHT -J: V1.72 - - -- S/N 2980 - -- Page 5 - - -- 1 Name of Room BEDROOM 2 t 2� Running Ft. Exposed Wall 36.0 Ft. Ft. 3, Room Dimensions, Ft. 12.0 �x 12.0 Ft. i x Ft. 4, Ceilngs,Ft , Condit. Option, 8. , heat /cool TYPE OF ' `CST` HTM Area ` Btuh EXPOSURE ; !NO. ;Htg ;Clg ;Length; Htg Clg 5 ! b ! Gross `a`14B' 3.3' 1.2 Exposed t ! 00 0.0 Walls and c 1 0.01 0.0 ! Partitions td ! 0.0 0.0 t t et 0.0 0.0 ,f, , 0.0, 0.0 6' Windows 'a' 1C'26.6' ** ! & Glass ! b t 1C ** Doors Htg. t c t 1C 26.6' ** t t 0.0 ** 1 i e i 1 0.0, ** ,f, , 0.0, ** 7' Windows ' North & Glass NE &NW Doors Clg. E &W t t SE &SW South Horz 1 0.0 14 0.0 24.0 , 0.0 8' Othr doors 'a'10D'10.6' 7.2 ,b, 0.0, 0.0 9' Net 'a14B' t 3.3' 1.2 ! Exposed bt 0 0 0.0 Walls and c � , 0.0 0.0 ! Partitions d t ! 0.0 0.0 t t t 0.0 0.0 ,f, , 0.0, 0.0 10` Ceilings 'a'16A'13.8'12.2 t l 1 0.0 0.0 c; ; 0.0! 0.0 11 Floors �b�19A� 0 0.0 c; ; 0.0; 0.0 12: Infiltration a ;16.7; 4.4 13:Subtot Btuh Loss= 6 +8.. +11 +12 14 Duct Btuh Loss 15, Total Btuh Loss = 13 +14 * * ** ; * * *0 % � 4; 67: 17 288' * * ** ' * * ** 0 * * ** 1 * * ** O ! * * ** 1 * * ** O 1 * * ** 1 * * ** 01 * * ** 1 * * ** 0; * * ** * * ** 24' 0! 0 ! 0 o! 987 * * ** 0 * * ** 987; * * ** 425' * * ** 638 * * ** 0 * * ** 0 * * ** 0, * * ** 0, * * ** 336 768 0 0 O ; 0' ! 0 0, -24' 901' 325 ! 0 ! ! 0 O ; l 0 ! 0 0, 0 144' 1984' 1762 0! 0! 0 144' 517' 0 0! 0! 0 40; 669; 174 * * ** 5133' * * ** 0 % 0 * * ** * * ** , 5133, * * ** 4; 67: 17 * * ** ' 1152' * * ** 0 %1 0 * * ** * * ** 1152, * * ** Area ' Btuh Length; Htg ; Clg * * ** * * ** * * ** ; * * ** * * ** * * ** %! ! * * ** * * ** ! ! * * ** 16 Int. Gains: People @ 300 0' * * ** ' 0 ' * * ** 1 APpl @ 1200 0 ! * * ** 0 * * ** 17 Subtot RSH Gain= 7 +8.. +12 +16 * * ** 1 * * ** t 3366 * * ** t * * ** t 18 D Btuh G 0 % * * ** 1 0 % t * * ** 19 Total RSH Gain = 17 +18 * * ** 1 * * ** t 3366 * * ** 1 * * ** t ,20, CFM Air Required , * * ** , 179, 157, * * ** ; , - -- Printout certified by ACCA to meet all requirements of Manual Form J -- MANUAL J: 7th Ed. RIGHT -J: V1.72 S/N 2980 RIGHT -J WINDOW DATA ab #: 5 -14 -98 S D W G L S S O N A S O 0 W C W S K I A L O T H V G N H V V H H N H Y R L A W R A H L G C R R G T A A L Z E M D G Z L O X Y T M R R LIVING ROOM n n a c n n b n 1 90 1.0 0.0 0.0 1.0 14.0 36.0 0.0 DINING ROOM KITCHEN n s a c n n b n 1 90 1.0 0.0 0.0 1.0 24.0 9.0 0.0 n w b c n n b n 1 90 1.0 0.0 0.0 1.0 48.0 9.0 0.0 FAMILY ROOM n e a c n n b n 1 90 1.0 0.0 0.0 1.0 48.0 16.0 0.0 J n s b c n n b n 1 90 1.0 0.0 0.0 1.0 24.0 35.0 0.0 n s b c n n b n 1 90 1.0 0.0 0.0 1.0 24.0 35.0 0.0 BEDROOM 1 n s a c n n b n 1 90 1.0 0.0 0.0 1.0 24.0 16.0 0.0 n e b c n n b n 1 90 1.0 0.0 0.0 1.0 48.0 16.0 0.0 BATH 1 { n e a c n n b n 1 90 1.0 0.0 0.0 1.0 48.0 4.0 0.0 BATH 2 n e a c n n b n 1 90 1.0 0.0 0.0 1.0 48.0 4.0 0.0 BEDROOM 2 1 n e a c n n b n 1 90 1.0 0.0 0.0 1.0 48.0 16.0 0.0 D n n b c n n b n 1 90 1.0 0.0 0.0 1.0 14.0 24.0 0.0 PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date S" 3 - � c tC Job Address / ° 3) Ate 9 5 t ax Folio Legal Description Historically Designated: Yes No Owner/Lessee / Tenant/ Br! Ajc5 Master Permit # V2ft6 Owner's Address 4/C 9/ S� Si • Phone ` ;'S - N - C30% Contrac ' Cox Qualifier VPS ki\\ \ (2 2 ( \ Ps � �- SS #`) Phone L% ✓ aas State #(.. Municipal # Competency # Architect/Engineer Address Bonding Company Address Mortgagor Notary as to Owner My Commission E FEES: PERMIT er and/or Cs do President Date ature of ®, i on F tin Date o22k. r,,i.9.8iO J k CV -#4E42 ` .. ') MARCH 11.1899 .1- 13F tr." RADON Jc:)N C —J b Address A dd \ Z SS S� Ins. Co. Permit Type (circle one): BUIL G ELEC CAL PLUMBING ECHANICAL i' OOFINGG PAVING FENCE SIGN WORK DESCRIPTION Square Ft. Estimated Cost (value) S WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is a c e and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the abo -ram d " , . tor to do the work stated. Signature of Contractor or Owner- Date Notary as to Contractor or Owner - Builder My Commission • HELENA HERNANDEZ z •_' oCOMMISSION 11 CC444542 -EXPIRES MARCH 12.1999 C.C.F. / �" NOTARY BOND 5/, ‘? /9.ef Date APPROVED: Zoning Building Electrical Mechanical `� �7 Plumbing Engineering NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. 1131010200050 STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: 32 NE 9 2. Description of improvement: A/C installation 98R233358 1998 MAY 18 09 :42 u - to • • 3. Owner(s) name and address: B r i n s f i e l d Jones 32 NE 91 Street Mi4m4 ShnrPS, P1 111Rq Interest in property: Owner Name and address of fee simple titleholder: 4. Contractor's name and address: Temp Conditioning Service, Inc. PO Box 557054 Miami, Fl 33255 5. Surety:(Payment bond required by owner from contractor, if ar4ATE OF FLORIDA, COUN TY of DDAD Ji:�r3b carte! oho Geis Is c onto Alin O r 9 . O Name and address: / / 0" �1 er.r-;rta Gi.rd in Citi& office an Amount of bond $ ;TAY _ A c 19 , W VNESS my fr ,d and O4r;ciol Soo!. 6. Lender's name and address: (,AP7'1 (Bl i l ! :ircuit and rnunny C:uu 9s ' 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) May 18, 1999 Q J Prepared by: Temp Conditioning Service, Inc. S4'nature of owne Print Owners Name'r WSJ Jd ic s Sworn to and subscribed before me this /`'� o day f ,199g tsv Pre KB.E A Nl tNAN= z ocommtssloNN 1 Address: PO Box 557054 o Notary Public E >� AR 121 0.4 71 Nctara's e✓1 q /7L7! 4GE'e t My Commission Expires: Miami, F1 11299 � c LLLjI31 C.:Cr= L. r , R l Sec- $.LL Afr conditiaaiag regulation. (a) All individual afr caadit:aaiag units irs�.alled a walls or Rindaws shall be reap lly aac and to the Fails by approvesi =ethocs. traits aver public property, paths of avws ar =ore than. ter. (10) feet above grade qlt' iT be secrzed :o the s�c- tare by bai= or stews co mist hari=ntai wind toads. S =its c-- . ver:ng Mare than eig (S) inches as :he arrarbar of a bosiciimw shall be ss=ppar.ed by steel angle brae cat sec r by Gait•... Salta '.a masanry snail be set in Lead shieics or 14— TT47 rat-mis 'ta fastenings. (b) The tailaoing specai rrq�.• -.. -sett t�*� n apply the ca- t: -i .. egt !a of :.bile :Luisa= fro= air c-+Srjr-^rwvs , r" , e. - 7: (1) All eacipp~ezt. err.:rg ar ae-• '•ar id ea. -eg i of to icn. s it be :maintained is goat = or‘-._:_.sr orier. Eaeir_er: sa located t uc per i apezcrg poises eaaca a muisz :ce co adja=c Qw err or o=paatI wall be gra- vided with sc untipreating, or sa td- a.cscrci: 3 batteLl. or u_ es. as approved to insure e =a n �,= at a. _- sanabie maisa ieveL All eecipzrea.t on outer Rats. an roofs. ar is other exposed it:coda:1s. which are =duly daisy. and which causes 'MEd cat :fah-." fr ad i ii g property owners or oc'. bats. =ay be r eas=ired to be relocated. redesi aadlor en- . eased w noise - retarding mater aLs he in the opinion of th_ b = omr,t, such Las is r. nary ar would be .fecr.ive. „(s) Special =rzid=adon s h a ll b give= to the pi =--ring of all ft=s ins-..allarkins the raise is= to ad- joinir• graper^r, owners or ocpaaLS. and the br-'Tr;T on „ ==I shall have authar':.y ta r jet ar require the rede- sign of any system% Which. is his opinion. world ease scci taaise arrisaa= (c) V ioIacaa of this sear. shag be p ;s- as is haw or =ay her9aker be provided by Law. (Orj.1 Na. 299. 14 1-4, 2.21-61) T F+ , �VL � race the 'Z►.T' Je Cr ^ o-e . " 11 r ;44 T 1 C=1 ir:.th !*.e. q • Date 5 - 15 - 9g Job Address 32- r3 r 6} 1 ST Tax Folio Legal Description Owner/Lessee / Tenant ASP 1E1_3) Owner's Address 3 2- rJ E all ST REET M I a r•� Contracting Co. G & G ELECTRICAL CO., Qualifier IP rJ LA r l S t a t e # EP, a O0 L ") Municipal # Architect/Engineer Bonding Company widia Notary as to Owner and/or Con My Commission Expires: 493 ,�� PAULA A. GRAY O COMMISSION # CC 402420 hul Q EXPIRES AUG 23,1998 BONDED HRU ' OF F‘ ATLANTIC BO CO., INC. FEES: PERMIT * - ON PERMIT APPLICATION FOR MIAMI SHORES VILLAGE 51 _Tr4C ondo President Date 51149S Date Historically Designated: Yes No Master Permit # f y,i is(i� IA 7 0 7 SN QR. E S Phone 305 - 757- 060 Address / 0 3o VJ vv Tr R.K M'AM i FL 33/ L9 SS# . Phone 3a5 655- O 7.1 Competency # 97 EOdo I g t f Ins. Co. Address Address Mortgagor < Address Permit Type (circle one): BUILD ! ' G ELECTRICAL P MBING CHANIC ROOFING PAVING FENCE SIGN Square Ft. Estimated Cost (value) - 33 00 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulatin: construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. C.C.F. Sign e of Contra or Owner- Builder 0,4 a Notary as to Contractor or Owner- V i1de My Commission Expires: ~ I�I Ud, c COMMISSION # CC 402420 0 !MI Q EXPIRES AUD G THRU 2 3,1998 � ^` BONDE ' OF FL ATLANTIC BONDING CO., INC. NOTARY BOND TOTAL DUE S- /3- q8 Date 5,13 / 6)1 S l Date APPROVED: Zoning Building Electrical Mechanical Plumbing Engineering q. , n � �� � � '� � n � j--) - (27o C & C Electrical Co., Inc. P.O. Box 4451 R 9/ Hollywood, Florida 33083 (305) 655 -0972 (/ 1 p7 3 od • 4 Cu IN 3/4' COND. / to CALM —ro 0 2/0 TI-IW, Cu IN 2' COND. 120/240 V, 3 WIRE, 1- PN,4$E #2/0 tNW, Cu IN 2' COND ELECTRICAL RISER n.t.s. GROUNDED TO GROUND ROD (2) 5/8' X 10' -0' LONG 40 -0' APART DRIVEN INTO TWE GROUND 8' -0' MINIMUM „ .V, PAULA A. GRAY r- COMMISSION # CC 402420 IR g EXPIRES AUG 23,1998 BO THRU " \ ' ATLANTIC BONDING CO., INC. ELECTRICAL SCHEDULE • 'ri_- • ` a r _ • 1'Fb Arra VC7LTAGE acre WRE MAW E MAW! MINT MANUFACTUFER TYPE • d0 120/240 24 3 1 1.LIC6 LOAD CENTER Bil 11 M CCM. NCB{ WATTS R 811 um =EX mg WATTS 1d"tiCS . rCLE Arm SERVING POLE WIPE SERVING 1 1 2 50 RANGE 12 00 2 12 1/2 1 20 SMALL APPL 1500 3 6 4 12 1/2 1 20 SMALL APPL - 1500 5 1/2 2 30 DRYER 5000 6 12 1/2 1 20 OPEN 15 00 - 8 12 1/2 1 20 ( GARB- D 15F? 1r N ' 9 10 1/2 � � r 30 W4T ER HEATER 45 10 12 1/2 1 20 DISH WASHER 1500 . 11 12 12 1/2 1 20 REFRICx 1500 13 12 1/2 1 20 _ W,451 -ER 1500 • 14 12 , 1/2 1 20 SPARE 1500 15 12 1/2 1 20 IJGWT1t.6 6154 16 12 1/2 1 20 RECEPT - - -- � 11 12 12 1 - 20 L1G1-TN - __ 18 12 1/2 ' 1 20 RECEPT - - -- 1S 12 1/2 1 20 LIG 4T1ALrs ---- 20 12 in 1 20 REGEPT - - -- . - 21 12 1/2 1 20 SPARE 1500 22 12 1/2 1 20 RECEPT ---- 23 12 12 1 20 ESC4-1. FAN 1500 24 1Z 12 1 20 RECEPT - - -- r 25 6 1 2 50 _ G. U. 4500 26 12 , 1/2 1 20 RECEPT . - - -- - 21 28 12 in 1 --- 20 I RECEPT — - - -- 29 6 1 2 50 A H. LL 6800 30 12 1 20 RECEPT - - -- 31. 32' - jj TOTAL: 52,554 WATTS LOAD SUMMARY : 1St 10 ,000 uJ4 I T5 31,154 .. WATT 5 A/C 11300 _ WATTS 100% 40% 125% 10,000 12,462 14,125 l 36,551 / 52.45 AtIF i