Loading...
PLANSTITLE: COVER SHEET / SITE PLAN REVISED BY: :31V0 REMARKS: 'ON TITLE: PROPOSED BREEZEWAY ENCLOSURE TO THE RESIDENCE OF: MR. and MRS. MATHIAS CABOUR PROJECT: 145 Northeast 91st Street, Miami, Florida_ DRAWN BY: MJA CHECKED BY: EMM ATTACHMENT NO.: ATTACHMENT# DRAWING FILE NO.: 2004 - 025 DATE: 02/24/2005 SCALE: NOTED SHEET NUMBER: 1 of 5 PROPOSED BREEZEWAY E \Ci3OS ZONING DATA ZONING: R - 1 Single Family Residential HEIGHT (to ridge) 13' -0" NET LAND AREA 13034 S.F. LOT COVERAGE (everything under roof) 2221 F. (l1.0%) SET BACKS: REQUIRED PROVIDED FRONT 25' -0" 25' -0' SIDE 10' -0" 10' -3" SIDE STREET N/A N/A REAR 25' -0" 69' -6" NOTES: In addition to the requirements of this permit, there may be additional restrictions a pplicable to this property that may be found in the Public Records of this County. Section 553.19(10), Florida Statutes, Effective 1/10/81. A separate permit will be required for all driveway approaches onto public right of way. Contact Public Works Departament. The height of fences, wall and hedges shall not exceed 2.5 feet in height within 10 Feet of the edge of any driveway leading to a right of way. The height of fences fs being measured form grade. Grade = Elevation of public sidewalk or the crown of road. Lot will be graded so as to prevent direct overland discharge or stormwater onto adjacent property. 1 4 Strt, 1 RE TO T r J l mi, F1�flQ IP] RESIDENC E 0 1. I 10' -3" 5' S r T DEWAL< EXISTING GARAGE LOT 20 EXIST. SEPTIC TANK 4 DRAINFIELD - EXISTING".• •• CARPORT •• . TO BE ENCLOSED L l l EXISTING DRIVEWAY r a SITE PLAN 1/8" L EX r r J j J STING 1 - STORY RESIDENCE Northeast 91st, Street LOT 21 L L 4, C4 A C LEGAL DESCRIPTION 16' -1" w z LOT 20 4 21, BLOCK 24 OF "AMENDED PLAT OF MIAMI SNORES SECTION NO. 1" ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 10 AT F'AG E 1� OF THE PUBLIC RECORDS OF MIAMI -DADE COUNTY, FLORIDA. /2 Eusebio M. Mora Architect Fla. Lic. # AR0011732 6761 Southwest 68th Terrace Miami, Florida 3 3 1 4 3 (305) 7 4 0— 5 1 8 5 WINDOW SCHEDULE MARK STAND. WIDTH HEIGHT TYPE FRAME REMARKS ® HR 1240 12" 48 " OLL HORIZONTAL ROLLING R ALUMINUM FINISH TO MATCH EXIST. LllINDOWS FINISH TO MATCH EXIST. '0N lag (2) 3' -0" 6' 43" 1 -3/4" SWING ALUM. FRENCH FINISH TO MATCI4 EXIST. PROJECT: 145 Northeast 91st Street, Miami, Florida. NOTES: I - SINGLE HUNG EGRESS TYPE WINDOW OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS 4 PROVIDING A CLEAR OPENING OF NOT LESS THAN 20" IN WIDTH, 24" IN HEIGHT 4 5.1 S.F. IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" OFF THE FLOOR ONE EGRESS TYPE WINDOW TO BE INSTALLED IN EACH BEDROOM. 2 - PROVIDE HURRICANE SHUTTERS AS PER SF.B.C. 3 - PROVIDE TRANSLUCENT GLAZING AT BATHROOM WINDOWS. DOOR SCHEDULE MARK WIDTH HEIGHT THICK TYPE DESCRIPTION REMARKS S T ml FIXED SIDELIGHTS l2) 2' -6" UJ/ 6' -8" 1 -3/4" SWING ALUM. FRENCH FINISH TO MATCH EXIST. '0N lag (2) 3' -0" 6' 43" 1 -3/4" SWING ALUM. FRENCH FINISH TO MATCI4 EXIST. PROJECT: 145 Northeast 91st Street, Miami, Florida. IA1 DRAWN BY: MJA CHECKED BY: EMM TITLE: FLOOR / FOUNDATION PLAN REVISED BY: :BIya REMARKS: '0N PROJECT: 145 Northeast 91st Street, Miami, Florida. IA1 DRAWN BY: MJA CHECKED BY: EMM ATTACHMENT NO.: ATTACH MENT# DRAWING FILE NO.: 2005 -009 DATE: 02/25/2005 SCALE: NOTED SHEET NUMBER: 2 OF 5 (1) " 5 IN GROUT FILLED CELL fl ALL NEW DOOR LOCATION ONLY 1" x 4" P.T. WD. BUCK W/ 1/4" X 2" "TAPCON " SCREUJS a 4" FROM THE ENDS 4 15" O.G. MAX. ELSEWHERE, EMBEDDED IN CAULKING IMPACT RESISTANT GLAZING OR STORM SHUTTERS DOOR/WINDOW BUCK DETAIL 1 -1/2" JAMB / HEAD SIMILAR SILL 2" 0 0 0 9' -0" EXIST OPNG 18" TYP 3'4" AT EXIST DOOR TO GARAGE WINDOW SILL DETAIL 1 -1/2" O 0 0 PROVIDE 1/2" x 12" STEEL PLATE ON ONE SIDE (Inside) OF EXISTING CONC. TIE BEAM W/ 5/8" THRU BOLTS 0 18 0.0. STAGERRED. LOWER PORTION OF CONC. TIE BEAM TO REMOVED TO PROVIDE CLEARANCE FOR NEW DOORS & SIDELITES EXISTING WALLS & COLUMNS TO REMAIN REMOVED TO PROVIDE CLEARANCE FOR NEW DOORS & SIDELITES MARBLE SILL IMPACT RESISTANT GLAZING OR STORM SHUTTERS CAULKING ALL AROUND 4" x 8" GONG CAP W/ (1) 5 8" EXIST. DOOR 6" EXISTING FLOOR PLAN 1/4" 00 1' -8" 00 EXIST. ONE -CAR GARAGE 13' -4" EXIST. SHOWER EXIST. . . . DOOR . EXIST. DOOR LEVEL 77777777 EXIST. WINDO EXIS 000" ......... ..... EXIST. ONE -CAR GARAGE 11' 23 EXIST. BREEZEWAY FIXED rROVIDE 1/2' x 12' STEEL PLATE ON ONE SIDE OF EXISTING CONC. TE BEAM — W/ 5/8' THRU BOOS 6 STAGERED LOWER PORTION OF CONC. TIE BEAM TO REMOVED TO PROVIDE CLEARANCE FOR NEW DOORS & SIDELITES PROPOSED FAMILY ROOM 11' -0" x 26'-2' BLOCK -LIP EXIST WINDOW PROVIDE NEW 1/2" DRYWALL ON MTL. FURRING STRIPS ® 16" O.C. 9 EXISTING BREEZEWAY CEILING. PROVIDE R -30 BATT INSULATION IN EXIST. BREEZEWAY CEILING. 0 a T-2 CAT. I I SAFETY GLASS 11' FIXED 0 0 6" EXIST. DOOR 6" EXIST. DOOR L 00 CG O � r E L OQ oq 54' -2" BATH EXIST. KITCHEN EXIST. BEDROOM EXIST. 0A0 WINDOW EXIST. KITCHEN EXIST. BEDROOM EXIST. WINDOW W.I.C. W.I.C. 11' -1" STEEL PLATE DETAIL NTS PROPOSED FLOOR PLAN 1/4" EXISTING RESIDENCE TO REMAIN A5 -15, NOTE: ALL NEW EXTERIOR WINDOWS SHALL BE PROVIDED WITH EITHER IMPACT GLASS OR HURRICANE SHUTTERS AS PER F.B.C. 0 EXIST. DINING ROOM EXIST. LIVING ROOM CAT. 1 1 CAT. I I SAFETY GLASS SAFETY GLASS EXIST. DINING ROOM EXIST. LIVING ROOM 0 EXIT. WINDOW TO BE REMOVED AND REPLACE WITH NEW FRENCH DOORS. Eusebio M. Mora Architect Fla. Lic. # AR0011732 6761 Southwest 68th Terrac€ Miami, Florida 3 3 1 4 3 (305) 740 -5 1 85 TITLE: FLOOR / FOUNDATION PLAN REVISED BY: SOIL STATEMENT INSPECTION OF THE SITE INDICATES UNDIS11J ED SAND ROCK WITH A BEARING CAPACITY OF 2000 THE ARCHITECT SHALL PROVIDE A SIGN 4 SEALED LETTER ATTESTING THAT THE SITE HAS BEEN OBSERVED AND THE FOUNDATION CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN 15 BASED. =�1VQ '0N PROJECT: 145 Northeast 91st Street, Miami, Florida. IA1 DRAWN BY: MJA CHECKED BY: EMM ATTACHMENT NO.: ATTACH M ENT# DRAWING FILE NO.: 2005 -009 DATE: 02/25/2005 SCALE: NOTED SHEET NUMBER: • 3 of 5 COLUMN SCHEDULE 1 1 • 5 VERT. IN CONC. FILLED BLK. CELL FROM FTG. TO T. TYP. SOIL STATEMENT INSPECTION OF THE SITE INDICATES UNDIS11J ED SAND ROCK WITH A BEARING CAPACITY OF 2000 THE ARCHITECT SHALL PROVIDE A SIGN 4 SEALED LETTER ATTESTING THAT THE SITE HAS BEEN OBSERVED AND THE FOUNDATION CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN 15 BASED. ciA ELE: =+ S 2" M TOP OF TIE BEAM EXIST WOOD ROOF JOISTS e 24" O.G. NEW R - 19 BATT INSULATION DRYWALL CEILING ON METAL FURRING STRIPS AT 16" O.G. TYP. I "X4" P.T. CONT. FIRE STOP. EXIST GONG. TIE BEAM s CARPORT WINDOW AS PER SCHEDULE NEUJ 1/2" DRYWALL TAPED ON I "X 2" P.T. WD. FURRING AT 16" O.0 TYP. NEW R -5 BATT OR BLOWN INSULATION NEW 4" HT. WD. BASE TYP, 1/2" EXPANSION JOINT NEUJ 6" CONC. SLAB W /6 "X6" •10/10 WWM ON 6 MILL VISQUEEN VAPOR BARRIER OVER EXIST. GARAGE FLOOR SLAB V ELE:i+ 0' -0" FIN. FL. CONC. SLAB = TTF TTI- TTI TTI— FT I -1 —1 • AT EXISTING CARPORT EXISTING 8 "x 12" CONC. TIE BEAM DOWEL 4 EPDXY GROUT • 5 VERT, BAR INTO EXIST. CONC. TIE BM. 6" MIN. NEW 8" CONC. BLK PROVIDE I •5 VERTICAL DOWEL 4 GROUT FILL EACH CELL EXISTING 10 "x 16" CONC. FTG DOWEL 4 EPDXY GROUT • 5 VERT. BAR INTO EXISTING CONC. FTG. 6" MIN. DETAIL 3/4" NEW GROUT FILLED CELL DETAIL l fl — Il — lll Ill 1= 1 1 —I 1 I -1 I I -1 I I —I 1I— WALL SECTION 3/4" EXIST ROOFING TO BEAN EXIST HURR STRAPS 3 "x3" (26 GA.) GAL V. MTL. DRIP 1/2" SMOOTH STUCCO S" CONC. BLOCK WALL. TYP. W/ "DURAWALL" HOR LADDER TYPE REINFORCEMENT "9 EVERY OTHER COURSE 1/2" SMOOTH STUCCO GRADE EXIST. CONC. FTG. COLUMN PROFILES • I "x2 " PT. WOOD STRIP 2 "x 6" WOOD FASCIA EXIST SCREEN VENT 4" x 16" g 4' -0" (TYP.) SMOOTH STUCCO ON PAPER BACKED GALV. MTL. RIBBED LATH TOP M. +6' -I0" TOP OF BEAM TOP M. +6 -8" TOP OF BEAM - TOP FF. +0' -0" F. F. GRADE -2' -8" EXIST. GRADE N EXIST. GONG BLK COLUMN AND CONC. TIE BEAM TO REMAIN T STUCCO TO MATCH EXIST. L 1' -8" EXIST. ROOFING TO REMAIN EXIST. OPENING BELOW WINDOW TO BE FILLED WITH CONC. BLK (1) • 5 IN GROUT FILLED CELL AT EACH OF END BELOW WINDOW. EXISTING RESIDENCE r EXIST. 1 0"x1 6" CONC. FTG. EXISTING RESIDENCE cApM . 10, 2 EXIST. WINDOW TO BE REMOVED AND REPLACE WITH NEU, FRENCH DOORS. 13' -4" /G' EXIST. 22' -4" L _ J 23' -4" EXIST COL, EXIS LFC. 10 "x16" CONC, FTG. l' -2" F OUNDATION PLAN (2) ZON0 " 4 6 80 FR. DR. S.F. ( +43.20) (- 53,70) REAR (NORTH) ELEVATION 1/4" HR 7240 WINDOW ZONE 4 18 S.F. ( +46.6) ( -50.7) 1 — I - t r J 1 PROPOSED ENCLOSURE EXIST. 10"x1 6" CONC. FTG. NEW 4" CONC. SLAB W /6 "X6 ", '10/10 LU1 ON 6 MILL. VISQUEEN VAPOR BARRIER OVER EXIST. GARAGE FLOOR SLAB 00 ■ 9' `I .D rfe G IM o 00 0 5' -6" 1/4" FRONT (SOUTH) ELEVATION 1/4" EXISTI COL' lal: EXIST. WINDOW XIST. COL. NEW 8" CONC. BLK PROVIDE I •5 VERT. DOWEL 4 GROUT FILL EACH CELL 41 J 1 (2) 2' -6" x 6' -8" FR. DR. w/ FIXED SIDELIGHTS LONE 5 60 S.F. (+43.20) (- 53.70) EXIST. WINDOW 54' -2" S - 3 " . . . . . . . EXJST. 1 Q "xJ 6." CONC." FTG. c t 1I' -1" 0 • EXIST; • F.C. 12' -6" NEW CONC STEPS EXIST.. 10 "x16 ". C.ONC, FTC. 0 • . EX ST. F.C. .r . - . - L__ EXISTING RESIDENCE 14 fe b W J EXIST. 10 "x16" CONC. FTG. ( PROPOSED ENCLOSURE EXIST. DOOR EXISTING RESIDENCE EXIST. WINDOW EXIST, 10 "x1.6" CONC. FTG. L TOP BM. +8' -10 "� TOP OF BEAM TOP BM. +6' -8" TOP OF BEAM TOP FF. +0' -0" r6 F GRADE -2' -0" EXIST. GRADE Eusebio M. Mora Architect Fla. Lic. # AR0011732 6761 Southwest 68th Terrace Miami, Florida 3 3 1 4 3 (305) 7 4 0— 5 1 8 5 EXIST. 10"x16" CONC. FTG. EXIST. 10"x16" CONC. FTG. ELECTRICAL SCHEDULE 'A' 120 / 240 V - 1 0 - 3 WIRE 200 A FLUSH MTD. PANEL CIRCUIT NUMBER WIRE SIZE DESCRIPTION -0 POLES 0 3 TRIP LOAD (WATTS) DEMAND NO. DEM. SWITCHED RECEPTACLE OUTLET REMARKS: EXISTING LOADS -0 SINGLE RECEPTACLE OUTLET >0‹ '0N 1 IV 0 14 LIGHTS / RECEIPT, (3W x 1555 S.F.) HEAT LAMP 4 EXHAUST FAN COMBO 1P-15 A 4665 FLOOR DUPLEX RECEPT OUTLET PROJECT: 145 Northeast 91st Street, Miami, Florida. *12 SMALL APPLIANCES (2 -0 1500 W) 1P-20 A 3000 4 SINGLE SPECIAL PURPOSE OUTLET *12 GFI RECEPTACL AT1-4ROOM GI 1F-20 A 1000 THREE UJAY SWITCH DRAWN BY: MJ A "12 REFRIGERATOR ATTACH M ENT# 1P-20 A 1000 DATE: 02/25/2005 *12 GARBAnE DISPOSAL SHEET NUMBER: 1P-20 A 600 WALL M. INCANDESCENT LI pg„ RANGE SURFACE I INCANDESCENT 2P-50 A 12000 AR REC5SSED 1-41 - PAT 0 )2 LIJA5I-4ER COMPUTER DATA / LAN OUTLET 1P-20 A 1000 * a DRYER 2P-30,4 5000 * 10 WATER 14EATER "I 2P-30A 4500 * e, A/C - A.N.U. W/ 15 KW HEATER 0 2P A 0100 , • a A/C-1 - C.U. 125% D 2P-40 A 6200 32,165 8100 NEW LOADS I -3 * 14 LIGi-iTS / RECEIPT. (3W x 28 5.F.) 1P-15 A S52 TOTAL LOAD 33,623 8100 * NON-CONCURRENT LOADS LOAD CALCULATIONS; 21,549 / 240 = 115 AMPS • J FIRST 10,000 UJ 0 100% = 10,000 WATTS REMAINING 23,623 UJ a 40% = 9,449 WATTS A/C LOAD 8,100 W a 100% . 8,100 WATTS TOTAL LOAD = 21,549 WATTS TITLE: FLOOR / FOUNDATION PLAN :,�8 a�SIA1 i DESCRIPTION MARK DESCRIPTION -0 :3lba SURF,ACE MTD. FLOURESCENT -7) SWITCHED RECEPTACLE OUTLET REMARKS: RECESSED MTD. FLOURESCENT -0 SINGLE RECEPTACLE OUTLET >0‹ '0N 1 IV QUADRUPLEX RECEPTACLE OUTLET 0[17 HEAT LAMP 4 EXHAUST FAN COMBO Stroke Control ilF FLOOR DUPLEX RECEPT OUTLET PROJECT: 145 Northeast 91st Street, Miami, Florida. ELECTRICAL PANEL 1 IAA 4 SINGLE SPECIAL PURPOSE OUTLET SINGLE POLE SUJITCH GI TELEPHONE OUTLET $3 THREE UJAY SWITCH DRAWN BY: MJ A CHECKED BY: EM M ATTACHMENT NO. : ATTACH M ENT# DRAWING FILE NO.: 2005 — 00 9 DATE: 02/25/2005 SCALE: NOTED SHEET NUMBER: 4 OF 5 SYMBOL LEGEND MARK DESCRIPTION MARK DESCRIPTION -0 DUPLEX RECEPTACLE OUTLET SURF,ACE MTD. FLOURESCENT -7) SWITCHED RECEPTACLE OUTLET () RECESSED MTD. FLOURESCENT -0 SINGLE RECEPTACLE OUTLET >0‹ FLOODLIGHTS SURFACE MTD. IV QUADRUPLEX RECEPTACLE OUTLET 0[17 HEAT LAMP 4 EXHAUST FAN COMBO Stroke Control ilF FLOOR DUPLEX RECEPT OUTLET ELECTRICAL PANEL 1 4 SINGLE SPECIAL PURPOSE OUTLET SINGLE POLE SUJITCH GI TELEPHONE OUTLET $3 THREE UJAY SWITCH Tv TELEvISION OUTLET D SINGLE POLE SWITCH W/ DIMMER 0 JUNCTION BOX DISCONNECT SUJITCH /® FAN BOX U.J/ INCANDESCENT FIXTURE a ExHAUST FAN . WALL M. INCANDESCENT LI DOOR BELL -e SURFACE I INCANDESCENT @ SMOKE DETECTORS TO ESE I-4,6,RDUJIRED 4 INTERCONNECTED TO NON-SLUITCI-ED KITCI-IEN OR E34THROOM LIGI-4TING CIRCUITS, AR REC5SSED 1-41 - PAT a --Elp) COMPUTER DATA / LAN OUTLET 1-4v40 DESIGN REQUIRES: YES NO Duct Stroke Detector X Fire Damper X Smoke Damicer(s) X Fire Rated Enclosure X Fire Rated R/Cellin Assernbl X Fire Stoppinc3 X Stroke Control X ELECTRICAL NOTES 1. GROUNDED AMEX or "SMURF" MAY BE USED. 2. RIGID GALVANIZED STEEL CONDUIT SHALL BE USED WHERE EXPOSED UP TO 4 FEET AND SUBJECT TO MECHANICAL INJURY OR IN DAMP OR WET LOCATIONS. 3. STEEL RACEWAY INSTALLED UNDERGROUND SHALL BE PAINTED WITH TWO CoATS ESITIJMASTIC FAINT. 4, WALL OUTLET BOXES SHALL BE 4" SQUARE. CEILING OUTLET BOXES SHALL BE 4" OCTAGON OR SQUARE. 5. CONTRACTOR SHALL FURNISH AND INSTALL ALL ELECTRICAL PANELS, WIRING DEVICES, CONDUIT, WIRING, MISCELLANEOUS SYSTEM, ETC. AS SHOWN ON PLANS OR AS REQUIRED FOR ACOMPLETE ELECTRICAL INSTALLATION. 6. FIXTURES AND LAMPS SHALL BE FURNISHED BY THE OWNER AND INSTALLED BY THE ELECTRICAL CONTRACTOR, UNLESS NOTED OTHEREWISE. 7. PANELBOARD-ALL CURRENT CARRYING COMPONETS SHALL BE COPPER. SPLIT OR TWIN TYPE BREAKERS ARE NOT ACCEPTABLE. CIRCUIT DIRECTORIES SHALL BE NUMBERED CONSECUTIVELY ON THE LEFT SIDE TO 50% AND CONTINUED ON THE RIGHT SIDE. 8. DISCONNECT SWITCHES SHALL BE GENERAL DUTY. 9, PROVIDE PULL WIRE IN EACH EMPTY RACEWAY. 10. CONTRACTOR SHALL DO ALL CUTTING, SLEEVING, EXCAVATING AND BACKFILLING NECESSARY FOR THE INSTALLATION OF HIS EQUIPMENT AND THE PATCHING THEREAFTER. 11. CONTRACTOR SHALL INSTALL ALL STARTERS AND CONTROL DEVICES FURNISHED BY OTHER CRAFTS AND COMPLETE WIRING IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS AND APPROVED WIRING DIAGRAMS, ELECTRICAL EQUIPMENT FURNISHED BY OTHERS WILL BE CONNECTED UNDER THIS CONTRACT INCLUDING ALL NECESSARY WIRING, CONDUIT, AND FITTINGS. CONTROL WIRING SHALL BE UNDER THE SUPERVISION OF THE SUB-CONTRACTOR FURNISHING THE EQUIPMENT. 12. ELECTRICAL WORK SHALL COMPLY WITH ALL APPLICABLE LOCAL OR NATIONAL CODES AND WITH THE UTILITY COMPANY REGULATIONS. 13. PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING CHECK NAMEPLATE DATA OF AIR CONDITIONING EQUIPMENT, HOT WATER HEATERS, AND OTHER EQUIPMENT TO OBTAIN CORRECT WIRE SIZES AND OVERCURRENT PROTECTION. 14, ELECTRICAL INSTALLATION SHALL CONFORMTO REQUIREMENTS OF N.E.C. 110-16(a) AND N.E.C. 384-2 FOR PANELBOARDS, INCLUDING SPACES ABOVE THE EQUIPMENT. 15. CONTRACTOR SHALL PREWIRE ALL TELEPHONE OUTLETS WITH 4/C #24 TELEPHONE CABLE RUN IN PARTITIONS AND DROPPED CEILING FROM INCOMING TELEPHONE JUNCTION BOX. 16. CONTRACTOR SHALL PREWIRE ALL TELEVISION OUTLETS WITH RG58U COAXIAL CABLE RUN IN PARTITIONS AND DROPPED CEILINGS FROM INCOMING CABLE TV, JUNCTION BOX. ELECTRICAL INSTALLATION DESIGNED OF THIS PLAN IS INCOMPUANCE AS SET FORTH BY STATE OF FLORIDA STATUTES MODEL ENERGY EFFICIENCY CODES. AIR CONDITIONING SPECIFICATIONS 1 THE WORK THAT IS TO BE DONE UNDER THIS HEADING INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT, PERMIT, FEES, INPECTIONS, TEST, INSURANCE, ETC. REQUIRED FOR THE COMPLETION OF THE AIR CONDITIONING SYSTEM SHOWN ON THE DRAWINGS AND/OR LISTED BELOW. 2 CONTRACTOR SHALL VISIT THE SITE TO BECOME FAMILIAR WITH ALL EXISTING CONDITIONS AND SCOPE OF WORK. CONTRACTOR SHALL SUBMIT ANY DESCREPANCIES TO ARCHITECT-ENGINEER FIFTEEN (15) DAYS PRIOR TO BIDS. THE NATURE THIS PROJECT INVOLVES THE REMODELING OF EXISTING FACILITIES, 3 INTERRUPTION )F EXISTING FACILITIES AND / OR SERVICES SHALL KEPT TO A MONIMUM AND THE CONTRACTOR SHALL FURNISH ALL MATERIALS REQUIRED VHENEVER TEMPORARY CONNECTIONS ARE NECESSARY TO MAINTAIN CONTINUITY OF SERVICES. COORDINATE ALL INTERRUPTIONS OF SERVICES WITH THE OWNER'S REPRESENTATIVE. 4 VENTILATION DUCTWORK SHALL BE GALVANIZED STEEL WITH GAUGES, DUCT CONSTUTIDNS, BRACING AND SUSPENSION IN ACCORDANCE WITH THE RECOMMENDATIONS SET FORTH IN THE LATEST EDITION OF THE ASHRAE GUIDE AND SMACNA STANDARDS. DUCT SIZES SHOWN ARE "AIRSIDE" DIMENSION. VERIFY EXACT LOCATION OF DUCT WITH RESPECT TO STRUCTURE BEFORE FABRICATION. 5 FLEXIBLE DUCT SHALL BE SELF-SUPPORTING ALUMINUM CONSTRUTION WITH 1' THICK BLANKET TYPE INSULATON WITH EXTERIOR VAPOR BARRIER PROVIDE SPIN COLLAR WITH DAMPER AND EXTRACTOR WHERE FLEXIBLE DUCT IS CONNECTED TO RECTANGULAR DUCTWORK, 6 AIR CONDITIONING SUPPLY AND RETURN DUCTWORK SHALL BE 1-1/2" R-6 FIBERGLASS U.L 181 LISTED. CLASS 1' AIR DUCTWORK SHALL BE FABRICATED IN ACCORDANCE WITH S.M.A.C.N.A. STANDARDS. 7 ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUTION AND ITS STRICT COMPLIANCE WITH ALL APPLICABLE CODES AND STANDARDS. 8 VERIFY ALL DIMENSIONS WITH STRUCTURE PRIOR TO ANY FABRICATION OR INSTALLATION. 9 SUBMIT SHOP DRAWING OF ALL MATERIALS AND EQUIPMENTFOR APPROVAL PRIOR TO FABRICATION. 10 OBTAIN FULL INFORMATION REGARDING PECULIARITIES AND LIMITATIONS OF SPACE AVAILBLE FOR INSTALLATION OF THE EQUIPMENT AND MATERIALS UNDER CONTRACT.PROVIDE READY ACCESSIBILITY TO DAMPERS, VALVES AND OTHER APPARATUS, INCLUDING ANY PART OF SYSTEM REQUIRED TO BE REACHED FOR MAINTENANCE AND OPERATIONS. VIBRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURER RECOMMENDATIONS TO ELIMINATE ANY EQUIPMENT NOISE FROM BEING HEARD, 12 CUT ALL OPENINGS AND CHASES REQUIRED TO ACCOMMODATE THE WORK UNDER THIS DIVISION AND REPAIR ALL FLOORS, ETC. DAMAGED BY SUCH CUTTINGS. ALL WORK DONE UNDER THIS HEADING MUST CONFORM IN EVERY RESPECT TO FINISH AND QUALITY MATERIALS AND WORKMANSHIP SPECIFIED UNDER APPROPRIATE SECTIONS FOR THE BUILDING. 13 GUARANTEES: A ALL COMPRESSOR MOTORS ON NEW EQUIPMENT FURNISHED UNDER THIS CONTRACT SHALL HAVE A 5 YEARS PRODUCT GUARANTEE FROM DATE OF START-UP. B CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN 1 YEAR FROM DATE OF ACCEPTANCE. 14 TESTING: A ALL REFRIGERANT HIGH SIDE PIPING TO 300 PSIG LOW SIDE TO 150 PSIG AFTER TESTING EVACUATE SYSTEM TO 28" MERCURY GAUGE PRESSURE WITH VACUUM PUMP.HOLD FOR 25 HOIJRS WITH PUMP OFF BREAK VACCUM WITH REFRIGERANT. B BALANCE AIR SYSTEM TO DELIVER QUANTITIES AND EACH OUTLET WITHIN 5 PERCENT USING A.A.B.C. PROCEDURES AND TESTS SUBMIT AIR BALANCE TEST RESULTS FOR APPROVAL PRIOR TO FINAL INSPECTION, 15 REFRIGERATION SUCTION PIPING SHALL BE INSULATED WITH 3/4" INCOAFELX. ARMAFELX INSULATION MAY ONLY BE USED IN NON-PLENUM AREAS. FINISH WHERE EXPOSED WITH 2 COATS OF WHITE LATEX PAIN ALL AS PER MANUFACTURER'S INSTRUCTION. 16 ALL REFRIGERANT PIPING SHALL BE TYPE "K" HARD COPPER, TOGETHER WITH WROUGHT COOPER SOLDER. FITTINGS JOINTS SHALL BE MADE WITH SILVER SOLDER OR "SILFOS" ALL CONDENSATE DRAIN PIPING TO BE SCHEDULE 40 TYPE II HIGH IMPACT PVC WITH SLIP J)INT FITTING OF THE SAME MATERIALS WITH AN APPROVED SOLVENT INSTALLED IN A MANNER RECOMMENDED BY THE FITTING MANUFACTUKR. 17 DUCT MOUNTED SMOKE DETECTORS SHALL BE EDWANS GS MODEL No 62648 IONIZATION DETECTOR OR APPROVED EQUAL. DETECTOR TO BE INSTALLED PER UL268A DETECTORS SHALL COMPLY MILL ALL REQUIREMENTS LISTED ON N.F.P.A. 90A AND TIED TO FIRE ALARM SYSTEM. 11 EX1STING (3) TI--IUJ (CU) IN 2" CONDUIT TO F.P.L. X-MER EXIST COMBINATION ELECT. METER CAN 4 iac. EXIST 200 AMP WP MAIN DISCONNECT (2) 5/a3" x 10' GROUND RODS UJ/(I) 4 *2 (CU) 1N 3/4" CONDUIT ELECTRIC RISER EXISTING (3)-3/0 T-4W (CU) IN 2" CONDUIT BOND TO COLD 4 7 WATER LINE N.T.S. NOTE: ALL SAFETY SWITCHES TO HAVE 100,000 RMS SYS MINIMUM FAULT CURRENT RATING. (USE TYPE R FUSES REJECTION KIT AND SOLID NEUTRAL.) PANEL SPALL IBE DEAD FRONT CIRCUIT BREAKER TYPE AS SCHEDULED. CICUIT BREAKERS S1-44L HAVE A MINIMUM INTERRUPTING RATING OF 10,000 AMPS AT 120 VOLTS, 15,000 AMPS AT 271 VOLTS. 0 0 D. EXIST. ONE--CAR GARAGE . 0 0 . • EXIST. ONE-CAR GARAGE • flXED - PR POSED FAMILY ROOM GI ry I EX 1ST. FIXED NOTE: ALL FLEX AND RIGID DUCT TO BE A MIN. OF R-6 VALUE. Fl ED EXIST EX14. FAN THRU ROoF TO REMAIN EXISTING RESIDENCE TO REMAIN AS-1S. % T1-112U CLG. P-ekv FIXED cl PROPOSED FAMILY ROOM EXIT Exi-4. F4N THRU ROOF TO REMAIN EP)doii CFM THRU aa XIST. ELECTRICAL FLOOR PLAN 1/4" .......... .................. ..... ................................... ..................... ................................. ............................................... ................................ • 0 L og I. . .8". co.FLEX r- I( C--to MECHANICAL FLOOR PLAN 1/4" EXISTING RESIDENCE TO REMAIN A6-I6. BATH EXIST. KITCHEN EXIST. BEDROOM EXIST. KITCHEN EXIST. BEDROOM W.I.C. EXT. RID DUCT IN ATTIC. Eusebio M. Mora Architect Fla. Lc. # AR0011732 6761 Southwest 68th Terrace Miami, Florida 3 3 1 4 3 (305) 7 4 0 — 5 1 8 5 I i TITLE: FLOOR / FOUNDATION PLAN REVISED BY: :ILV REMARKS: '0N PROJECT: 145 Northeast 91st Street, Miami, Florida. IAA DRAWN BY: MJA CHECKED BY: ~ EMM ATTACHMENT NO.: ATTAC H M ENT# DRAWING FILE NO.: 2005 -009 DATE: 02/25/2005 SCALE: NOTED SHEET NUMBER: 5 of 5 SECURITY AND FORCED ENTRY NOTES ALL EXTERIOR DOORS, WINDOWS, GLASS AND GLAZING SHALL COMPLY AND BE PROVIDED WITH INTRUSION AND BURGLARY SECURITY DEVICES AS SET FORTH IN CHAPTER 36, SECURITY AND FORCED ENTRY OF THE FLORIDA BUILDING CODE, LATEST EDITION MAIN ENTRANCE DOOR: SINGLE DOORS SHALL BE LOCKED WITH COMBINATION DEAD LATCH AND DEAD BOLT SETS WITH A LATCH THROW MINIMUM OF 1/2" AND DEADBOLT WITH A MINIMUM THROW OF I" KEY OPERATED FROM THE EXTERIOR ALL WOOD JAMBS SHALL BE RABBETED TO PREVENT DEFEATING THE PURPOSE OF THE STRIKE AND THE INTEGRITY OF THE LOCK AND LATCH. DOORS SHALL BE INSTALLED WITH A VISION SCOPE. ALL HINGES EXPOSED TO THE EXTERIOR SHALL HAVE NON - REMOVABLE PINS. DOUBLE DOOR: THE ACTIVE LEAF OF PAIRS OF SWINGING DOORS TO THE EXTERIOR SHALL HAVE LOCKS AS REQUIRED FOR SINGLE DOORS OR HAVE MULTIPLE POINT LOCK WIT- 5/8" MINIMUM THROW BOLTS AND INSERTS, OPERATED BY A CYLINDER LOCK. THE INACTIVE LEAF SHALL HAVE A MULTIPLE POINT LOCK WITH 5/8" MINIMUM THROW BOLTS AND INSERTS. EXPOSED HINGES ON DOORS SHALL HAVE NON REMOVABLE PINS. GARAGE TO LIVING AREA DOORS THESE DOORS SHALL BE LOCKED WITH A LATCH AND A SINGLE DEAD BOLT WITH A I" MINIMUM THROW, OR A COMBINATION DEADLATC-4 AND DEADBOLT. GARAGE DOOR: OVERHEAD DOOR SHALL BE LOCKED AT MORE THAN ONE POINT WITH HARDENED BOLTS AND INSERTS, ENGAGING AT LEAST TWO OPPOSITE SIDES WITH A MINIMUM OF 5/8" PENETRATION. VENTS SHALL NOT EXCEED 8" IN LEAST DIMENSION AND SHALL NOT BE CLOSER THAN 40" TO THE INSIDE LOCK ACTIVATING DEVICE. SLIDING GLASS DOORS SLIDING GLASS DOORS SHALL BE INSTALLED AND CONSTRUCTED SO THAT PANELS CANNOT BE LIFTED FROM THE TRACKS W -EN IN LOCKED POSITION. DOORS SHALL HAVE NO SCREWS REMOVABLE FROM THE OUTSIDE NOR SHALL ANY DOOR LEAF WHEN CLOSED AND LOCKED BE OPERABLE FROM THE OUTSIDE SLIDING DOORS SHALL BE LOCKED WITH A PIVOTED H00K TYPE SINGLE BOLT. 10 RESIST SLIDING ON THE DOOR BY FORCE AND SHALL BE REINFORCED IN THE STRIKE AND LOCKED AREAS TO MAINTAIN BOLT STRENGTH EFFECTIVENESS. OTHER EXTERIOR DOORS EXTERIOR DOORS IF OPERABLE FROM THE EXTERIOR SHALL HAVE AT LEAST ONE LOCK THAT IS KEY - OPERATED FROM THE EXTERIOR WHERE A KEY -IN- THE -KNOB TYPE LOCK IS USED, PROVIDE AN AUXILIARY SINGLE DEAD BOLT LOCK KEY OPERATED FROM THE EXTERIOR. META! GRATES AND GRILLE -TYPE DOORS S -ALL BE PROVIDED WITH LOCKS DESIGNED TO PREVENT REACHING THE INSIDE ACTIVATOR FROM OUTSIDE DOORS. LOUVERS SHALL NOT BE INSTALLED IN THE EXTERIOR WALL OF AREAS REQUIRING SECURITY UNLESS THE LOUVERED AREA IS PROTECTED BY INTRUSION SECURITY DEVICES. LIGHTING: FOR THE PURPOSE OF SECURITY TI-4E AREAS IMMEDIATELY OUTSIDE OF EXTERIOR DOORS SHALL BE ILLUMINATED BY VANDAL- RESfSTANT GLOBES AND SUCH ILLUMINATION SHALL BE ACTIVATED DURING THE DARK PERIOD OF EVERY DAY. OPEN PARKING LOTS AND ACCESS THERETO, PARKING AND NON - ENCLOSED AREAS UNDER OR WITHIN BUILDINGS AT GRADE SHALL BE PROVIDE WITH A MAINTAINED MINIMUM OF ONE FOOT- CANDLE OF LIGHT ON THE PARKING AND WALKING SURFACES FROM DUSK UNTIL 10 MINUTES AFTER THE TERMINATION OF BUSINESS EACH OPERATING DAY. WINDOWS WINDOWS SHALL BE LOCKED WITH DEVICES ON THE INSIDE CAPABLE OF WITHSTANOING A FORCE OF 150 POUNDS APPLIED IN ANY OPERABLE DIRECTION AND WITH QUICK - OPENING DEVICES 50 THAT THEY MAY BE READILY OPENED FROM THE INSIDE IN CASE OF EMERGENCY. WINDOWS SHALL BE CONSTRUCTED THAT WHEN FIXED OR LOCKED CANNOT BE REMOVED FROM THEIR FRAMES FROM THE O,ITSIDE. HINGE PINS OF ALL EXTERIOR OPERABLE WINDOWS SHALL NAvE NON - REMOVABLE PINS OR BE OF INTERLOCKING STUB TYPE AND HAVE NON - EXPOSED SCREWS. BURGLAR GUARDS BURGLAR GUARDS IF PROVIDED 51-4ALL BE INSTALLED WITH QUICK OPENING DEVICES SO THAT THEY MAY BE READILY OPENED FROM T -E INSIDE FOR EMERGENCY EGRESS AND SHALL BE SO ATTACHED THAT WHEN OPENED THEY WILL NOT DROP TO THE GROUND. DECORATIVE MATERIALS PROVIDING COMPARABLE PROTECTION S -ALL BE ACCEPTABLE IN LIEU OF PLAIN METAL BARS AND GRILLES. OTHER INTERIOR DOORS: EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INSIDE THE CLOSET. EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN CASE OF AN EMERGENCY. SITE NOTES 1. PROVIDE ALL SITE CLEARING, EXCAVATION, FILL, BACKFILL, ROUGH, GRADING, SUB- GRADES AND COMPACTING AS INDICATED IN THE CONTRACT DOCUMENTS. 2. TREES TO REMAIN AND /OR RELOCATE AS SELECTED BY OWNERS -ALL BE PROTECTED AS REQUIRED 3. TREES TO BE REMOVED SHALL BE CUT AS DIRECTED BY OWNER ALL SITE CLEARING DEBRIS AND TREE STUMPS SHALL BE REMOVED FROM JOB SITE 4. IF SIDEWALK IS PROVIDED IT SHALL BE AS DIRECTED BY THE CORRESPONDING PUBLIC WORKS DEPARTMENT 5. COORDINATE WITH MECHANICAL, ELECTRICAL, AND LANDSCAPING PLANS FOR WATER LINES, DRAINAGE PIPES, UNDERGROUND ELECTRICAL CONDUITS IRRIGATION SYSTEMS AND ANY CONCEALED INSTALLATION THAT COULD BE DAMAGED �. MAINTAIN SITE CLEAN OF CONSTRUCTION DEBRIS 1. PROVIDE CERTIFIED SOIL TREATMENT PRIOR TO POURING OF SLAB 8. REFER TO SITE PLAN FOR SEWER DISPOSAL SYSTEM DRIVEWAYS GRADING AND FENCING STRUCTURAL and GENERAL NOTES 1. SOIL STATEMENT: A. VISUAL INSPECTION OF SOIL INDICATES UNDISTURBED SAND AND LIMEROCK WITH AN ALLOWABLE BEARING CAPACITY OF 2.0 KSF. (UNLESS NOTED OTHERWISE) B. PROVIDED PROPERLY COMPACTED NON - ORGANIC FILL TO 95 % MODIFIED PROCTOR C. OTHER AREA FOOTINGS SHALL BEAR ON SAID UNDISTURBED SAND AND ROCK 2. CONCRETE: A. COMPRESSIVE STRENGTH OF CONCRETE AY 28 DAYS NON- STRUCTURAL SLABS ON FILL 200 P.S.I. ALL OTHER CONCRETE 3000 P.S.I B. TESTS: A MINIMUM OF CONCRETE SPECIMENS SHALL BE TAKEN FROM EACH 50 CU. YDS. PORTION THEREOF. SPECIMENS SHALL BE TESTED ACCORDING TO ASTM C -39. ONE AT 3 DAYS ONE AT 1 DAYS AND THREE 4T 29 DAYS C. REINFORCING STEEL SHALL HAVE A MINIMUM CLEAR COVER AS FOLLOWS: 1) CONCRETE POURED AGAINST THE EARTH - 3" 2) CONCRETE EXPOSED TO EARTH OF WEATHER *5 OR SMALLER - 1 I/2" * ro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b = 1200 P.S.I. EXCEPT FOR 4 X 12 HEADER BEAMS WHICH MUST NAVE A MINIMUM OF 1500 P.S.I. C. ALL WOOD IN CONTACT W /CONCRETE, MASONRY, OR LATH SHALL BE PRESSURE TREATED AS PER THE "AMERICAN WOOD - PRESERVERS ASSOCIATION". 6. STRUCTURAL STEEL: A. PIPE COLUMNS MUST CONFORM WITH ASTM 453 GRADE B. PLATES AND ROLLED SECTIONS SHALL BE ASTM A -3& TUBE SECTION COLUMNS TO CONFORM WITH ASTM A -500 (TRADE B. B. BOLTS MUST CONFORM WITH ASTM A -235 C. PROVIDE TWO SHOP -COATS OF RUST INHIBITING PAINT. FABRICAT'ON AND ERECTION SHALL BE ACCORDANCE WITH A15C SPECIFICATIONS 7. SLABS ON FILL: A. TO BE PLACED ON CLEAN, NON - ORGANIC SOIL THOROUGHLY MOISTENED IMMEDIATELY BEFORE CONCRETE IS POURED. CONCRETE IS TO BE PLACED ON 0.00& IN wtSQUEEN VAPOR BARRIER SLABS ARE TO BE PLACED IN A "CHECKERBOARD" SEQUENCE. EACH SEGMENT OF WHICH IS NOT TO EXCEED A MAXIMUM AREAS OF 325 SQ. FT. OR 30 LINEAR FEET IN ANY ONE DIRECTION, 8. APPROVALS A. SUBMIT SHOP DRAWINGS FOR ITEMS 345 AS ABOVE B. SUBMIT LABORATORY REPORTS FOR ITEM 2 ABOVE C. A/C CONTRACTOR SHALL SUBMIT FOR ARCHITECTS APPROVAL SI -41%P DRAWINGS WH101-4 SHOW DUCT SIZE 4 LAYOUT, EQUIPMENT SIZE, MANUF, MODEL *AND COMPLIANCE WITH ENERGY CODE REQUIREMENTS SHOWN ON THE DRAWINGS. A/C CONTRACTOR SHALL BE FULLY RESPONSIBLE TO PROVIDE A SYSTEM WITH ADEQUATELY AND ECONOMICALLY ACHIEVES COMFORT LEVELS OF HEATING, COOLING, AND DEHUMIDIFICATION IN ACCORDANCE WITH 4S -RAE STANDARDS. 9. COORDINATION: A. COORDINATE ALL DIMENSIONS, ELEVATIONS AND OPENINGS WITH ARCHITECTURAL, ELECTRICAL AND MECHANICAL DRAWINGS REPORT ANY DISCREPANCIES TO OUR OFFICE. B. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS CN THE DRAWINGS AND AT THE JOB SITE AND IMMEDIATELY REPORT ANY INCONSISTENCIES TO THE ARCI4ITECT PRIOR TO FABRICATION C. GARAGE SHALL BE PROVIDED WITH A PERMANENT SIGN WITH 1/2" NIGH LETTERS LOCATED ON THEIR INSIDE FACE OF ANY EXTERIOR DOOR READING: " DANGER DO NOT OPERATE ENGINE WITH DOOR CLOSED. CARBON MONOXIDE EMISSION IS LETHAL" D. GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT /ENGINEER IN WRITING, OF ANY DISCREPANCY IN THE DRAWINGS OR INCONSISTENCIES WITH ANY AND ALL APPLICABLE CODES OR REGULATIONS, PRIOR TO ANY ACTION ON -41S PART. FAILURE TO DO SO WILL MAKE HIM RESPONSIBLE AND LIABLE UNDER HIS CONTRACT. MATERIAL LEGEND 0 CONCRETE BLOCK POURED CONCRETE (Small Scale) POURED CONCRETE (Large Scale) SYMBOL LEGEND PRECAST CONCRETE BRICK SLATE MORTAR BED / STUCCO SECTION MARKER DETAIL SYMBOL ELEVATION SYMBOL NORTH ARROW ROOM NAME OR NUMBER 10 -0" TO SCUD 10' -1" TO MASONRY Ill III TT1 III - 1 1 1 11I 4 II II II II II II II II II II II II II I II II II II I1 II II II II II II II II II II 001 ( STANDARD DIMENSIONING METHOD PARTITION II II II II 1 1 II II II II I II II II II 11 1 CONCRETE BLOCK STEEL FINISH WOOD ROUGH WOOD (BLOCKING) COMPACTED FILL BLANKET INSULATION RIGID INSULATION PLASTIC DOOR NUMBER WINDOW SYMBOL COLUMN AXIS DESIGNATION ELEVATION MARKER E I035 � EQUIPMENT SYMBOL t. Eusebio M. Mora Architect Fla. Lic, # AR0011732 6761 Southwest 68th Terrace Miami, Florida 3 3 1 4 3 (305) 7 4 0— 5 1 8 5 ,8 E 1.250 .750 FRAME HEAD C -3001 6063 -T5 MEETING RAIL C -3004 6063 -T6 SASH TOP RAIL C -3005 6063 -T6 SASH BOTTOM RAIL C -3006 6063 -T6 r r L0621 .062 2.062 SILL C -3002 6063 -T5 .062 ,812 SASH SIDE RAIL C -3007 6063 - T5 2.173 HOOK LOCK C -3009 6063 -T6 1.376 --�{ .062 X1,500 {�- HOR1Z, MUNTIN C -3010 6063 -T6 L376 -c-1,5001� VERT. MUNTIN C -�e1 4 6063-T5 1.126 .J6& L . 2.061 - FRAME JAMB C -3003 6063-T5 .062 ,812 '.u14 2.000 — — — FRAME CORNER DETAIL VENT CORNER ETAIL Engr. OR. HUMAYOUN FAROOQ STRUCTURES FLA. PE t 16557 6 2001 By MUNTIN COPING DETAIL PRODUCT R.ENMED 4CCEPTANCE N o . 0 I "(0 Z ,, OZ EXPIRATION DATE/JW(!y1 tz PRODUCT CONTI`CL X:VISION LUILD,./VG CODE COMPLIANCE CE OFFICE 0 z 0 ' z J z vs- M z J 0 0 M v1 vi c 0 N O . 0 v v o O 0 e 0 0 drawing no. W98 -25 sheet 5 of 5 ITEM g PART g REQD. DESCRIPTION REMARKS 1 C -3001 1 FRAME HEAD 6063 -T5 CALM 2 C -3002 1 FRAME SILL 6063 -76 (ALUM) 3 C -3003 2 FRAME JAMB 6063 -T5 (ALUM) 4 C -3004 1 MEETING RAIL 6063 -76 (ALUM) 5 _____ __C- 3005_ ___ 1 SASH TOP RAIL 6063,76 (ALUM/ - -.- - 6 C -3006 1 SASH BOTTOM RAIL 6063 -76 (ALUM) 8 C -3007 2 SASH SIDE RAIL 6063 -T5 (ALUM) 9 - AS READ. ASSEMBLY SCREWS N 8 X 1' P.H. PHILIPS CRS 10 C -3085 4/ VENT FACE GUIDES 2 -3/4' FROM ENDS 1 AT MIDSPAN NYLON 11 C -3009 2/ VENT SASH LATCH AT 6 -1/4' FROM ENDS 6063- T6CALUM), W/ S.S. LEAF SPRING , 12 3017 -G AS REQD. FIN SEAL PILE ULTRAFAB 13 C -3011 AS REQD. v'EATHER STRIP BULB VINYL WIBDRG 14 - AS REQD. SILICONE BACK BEDDING OH 10 SEALANT OR EQUAL 15 - AS READ. ALUM GLAZING BEAD ROLL FORMED ALUM. 16 - 2 BLOCK & TACKLE BALANCE 5/8' BOX, BLAKE SYSTEMS OR EQUIV. 17 C -3010 AS REQD. HORIZ. MUNTIN 6063 -76 (ALUM) 18 C -3014 AS READ, VERT, MUNTIN 6063 -T5 (ALUM) • TYPICAL ANCHORS SEE ELEV. FOR SPACING 0. a 0 C7 a 0 J 0 W 0 t ' ' • 7/8' X 2 -3/4' OPEN CELL FOAM PAD AT EACH WEEP SLOT 1 -3/4' X 3/16' WEEP SLOTS AT 2 -1/2' FROM EACH END ° d 4 a 1 1 4 I4 4 TYPICAL' ANCHORS SEE ELEV. FOR SPACING SINGLE HUNG WINDOW TRUE COLONIAL 1 BY OR 2 BY WOOD BUCK_ 1 BY OR 2 BY W000 BUCK 3/8' FOR 3/16' & 1/4' GLASS 5/16' FOR DSB GLASS D.L OPG. TYP, GLASS BITE EXTERIOR WINDOW WIDTH D.L. OPG. O VENT WIDTH En.r. DR. HUMAYOUN FAROOQ STRUCTURES FLA. PE O 16557 OCT 1 6 2001 WOOD BUCKS NOT BY CURV -A -TECH MUST SUSTAIN IMPOSED LOADS 1/4' SHIM 0 MAX. PRODUCT RENEWED e tOCE?FANCE Na (- / O L 3. 6 Z EXPIRATION DATE A 1 4 1 qr I, 21" PR' =DUCT COATROL Dt'✓ISit *N BIALDENG CODE COMPLIANCE OFFICE • TYPICAL ANCHORS 4 r SEE ELEV, AND CHART FOR SPACING z CD 0 0 O F-, O � o4 EL 0 N cr QQ oo N� - N Fs, w v F o M I z In � w .- 0 0 z z 0 z V) 2 z 0 M N N c 0 L 0 c 0 8 0 .n 0 0 ,c 0 8 e V 0 N 1 c0 3 0 0 - O drawing no. W98-25 sheet 4 of 5 TYPICAL ANCHORS SEE ELEV. FOR SPACING •; 0 J 7/8' X 2 -3/4' OPEN CELL FOAM PAD AT EACH WEEP SLOT f 1-3/4' X 3/16' WEEP SLOTS AT 2 -1/2' FROM EACH END 4 d' • 4 4 L_ a 4 _ t X z • e = S • ■ 1 SINGLE HUNG WINDOW 1 OVER 1 TY PICAL , ANCHORS ' � .• SEE ELEV, FOR SPACING W000 BUCKS NOT BY CURV —A —TECH, MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. ANCHORS: INTO 2BY WOOD BUCKS OR WOOD STRUCTURE 3/16' TAPCONS WITH 1 -3/8" MIN. PENETRATION INTO WOOD INTO 1BY W000 BUCKS OR INTO MASONRY 3/16' DIA. TAPCONS WITH 1 -1/4" MIN. EMBED INTO MASONRY GLAZING METHOD: USE ADHESIVE BEDDING COMPOUND OH 10 SEALANT NO. 051 —HM -270 OR EQUIVALENT COLOR TO MATCH GLASS & METAL FINISH SEALANT: FRAME CORNERS, FRAME SILL INSTALLATION SCREWS, VENT CORNER SEAMS AND FIXED MEETING RAIL AT END SEALED WITH 'SCHNEE MOREHEAD SM 5504' SEALANT. OR EQUIVALENT 1 BY OR 2 BY WOOD BUCK 1 BY OR 2 BY W000 BUCK VENT 0 ra----ur lll, -a ilium TYP, GLASS BITE 3/8' FOR 3/16' & 1/4' GLASS 3/16' FOR DSB GLASS D.L. OPG. 0 0 • OCT 1 6 2001 WIDTH EXTERIOR WINDOW WIDTH Engr. DR. HUMAYOUN FAROOQ STRUCTURES FL1. PE # 16557 WOOD BUCKS NOT BY CURV -A -TECH MUST SUSTAIN IMPOSED LOADS 1/4' SHIM O MAX. 1 PRODUCT RENEWED Axr,YrANCYN,, C: - (L Z .CZ EXPIRATION DATE N l 44.C✓ I ? )Di1 COI`' RCLVIVL;IOU BL IN3 Lt TDE COMP )AI`TCE O^FICE TYPICAL ANCHORS 4 SEE ELEV, AND CHART FOR SPACING 4 0 O 4, c 0 4, • t_ at 0 0 c 0 0. 0 N G) 'O T .0 0 0 0 rn 0) 8 0) F co , O "L 'ii Q. IX vwo 8 V N O � H N� 3 "' rn 0 rn o ---J Ua)=p 1 0 0 a drowing no. W98 -25 sheet 3 of 5 WINDOW DIMS. WIDTH 19 -1/8' 26 -1/2' 37' 53 -1/8 19 -1/8' 26 -1/2' 37' 53 -1/8 19 -1/8' 26 -1/2' 37' 53 -1/8 19 -1/8' 26 -1/2' 37' 53 -1/8 19 -1/8' 26 -1/2' 37' 53 -1/8 19 -1/8' 26 -1/2' 37' 53 -1/8 HEIGHT 26' 38 -3/8' 50 -5/8' 56' 63' 74 -1/4' 1 OVER 1 NUMBER OF DSB- ANNEALED GLASS ANCHORS /JAMB EXT. ( +) 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6' 6 8 8 8 8 BASED ON FTL -1962 DATED 3 -16 -98 TEST SIZE = 53-1/8" X 63" (1 OVER 1) TEST LOADS = +60.0, -60.0 PSF DESIGN LOADS = +40.0, -40.0 PSF WATER INFILTRATION TEST = 8.3 PSF TESTED GLASS = DSB - ANNEALED SERIES -300 ALUMINUM SINGLE HUNG WINDOW 1NT. ( -> 55.3 78.0 55,3 78.0 55.3 78,0 55,3 77,7 55,3 78.0 55.3 78.0 55.3 61.9 44,8 44.8 55.3 78.0 55,3 76,8 55.3 57.8 33.1 33.1 55.3 78,0 55.3 69.9 52.3 52.3 34.2 34.2 55.3 78.0 55.3 63,1 47.6 47.6 32.4 32.4 COMPARATIVE ANALYSIS CHART DESIGN LOAD CAPACITY - PSF 1 OVER 1 1 OVER 1 3 /16 "- ANNEALED GLASS 1/4 "- ANNEALED GLASS EXT. ( +) 55,3 55.3 55,3 55,3 55.3 55,3 55,3 55,3 55,3 55,3 55,3 55,3 55.3 . 55.3 55,3 55.3 55,3 55.3 55,3 50,9 55,3 55,3 55.3 47.9 1NT. ( -) 125.0 125,0 125.0 105.8 125.0 125,0 122.0 76.8 125.0 125.0 92.5 62.6 125,0 123.5 84,3 57,3 125.0 106.8 76,2 50,9 125.0 90.0 66.7 47,9 BASED ON FTL -1957 DATED 2 -25 -98 TEST SIZE = 53-1/8" X 74-1/4" (1 OVER 1) TEST LOADS = +75.0, -75.0 PSF DESIGN LOADS = +50.0, -50.0 PSF WATER INFILTRATION TEST = 8.3 PSF TESTED GLASS = 3J16 "- ANNEALED EXT. ( +) 1NT. ( -) 55,3 167.0 55,3 167.0 55.3 160.5 55,3 105.8 55.3 167.0 . 55,3 167,0 55,3 122.0 55.3 7T .3,8 55,3 167,0 55,3 167.0 55,3 104.1 55,3 62.6 55,3 167.0 . 55,3 156,0 55,3 999,6 , 55,3 58;6 55,3 167.0 55,3 138,7 55,3 95.8 54,5 54,5 55.3 167.0 55,3 121.4 55,3 50.0 50.0 EXT. ( +) 53,3 53.3 53,3 53,3 53,3 53,3 53,3 53,3 53,3 53,3 53,3 53,3 53,3 53,3 53,3 50.8 53,3 53,3 53,3 46.0 BASED ON FTL -1958 DATED 3 -1 -98 TEST SIZE = 53 -1/8" X 63" (8 OVER 8) TEST LOADS = +69.0, -69.0 PSF DESIGN LOADS = +46.0, -46.0 PSF WATER INFILTRATION TEST = 8.0 PSF TES I ED GLASS = DSB_ANNFAI Fn TRUE COLONIAL DSB - ANNEALED GLASS 1NT. (-) 78.0 78.0 78.0 78,0 78,0 78.0 78,0 70.7 78.0 78.0 78.0 55.4 78.0 78,0 78.0 50,8 78,0 78.0 71,5. 46.0 Engr. OR. HUMAYOUN FAROOQ STRUCTURES FU\. PE f 16557 ci• 11 6 200 PRODUCT RENEWED ACCEPTANCE No Cif / p 1. 3 EXPIRATION DATFN BY ODUCT. ON TROT, LTV'STON RU LD[N'; CCDE COMPLIANCE OFFICE 1. J 0 0 cn ) 0 cn rn M O :.d a c U 4) 4) O 0 O ,c 0 m o_ 1 drawing no. W98--25 sheet 2 of 5 DAY LIGHT OPG. DIMENSIONS 1/1 WDW. D.L OPG. (FIXED) D. L. OPENINGS II 11 II JLLL�G - Ir t1 I I I I I II II /• / 1 -_ — 77 TT it - - - -- LASS TYPEij EE CHARTS( II I 11 I 38 -3/8' 15- 15/16' 1 L I I 11 H /./ JL_ H H H H II 11 . 11 /.II H H H H 24 -3/4' 63' DAY LIGHT OPG. DIMENSIONS 1/1 WDW. WINDOW HEIGHTS D. L. OPENINGS 26' 9 -3/4' 38 -3/8' 15- 15/16' 50 -5/8' 22 -1/16' 56' 24 -3/4' 63' 28 -1/4' 74 -1/4' 33 -7/8' DAY LIGHT OPG. DIMENSIONS 1/1 WDW. WINDOW WIDTHS D. L. OPENINGS 19 -1/8' 14 -1/8' 26 -1/2' 21 -1/2' 37' 32' 53 -1/8 48 -1/8 FALSE HUNT INS (SURFACE APPLIED) MAY BE USED 53 1/8" WINDOW WIDTH 48 1/8" D.L OPG. (VENT) 50 1 /4" VENT WIDTH TYPICAL ELEVATION 1 OVER 1 TESTED UNIT FALSE MUNTINS (SURFACE APPLIED) MAY BE USED CENTER ANCHOR AT HEAD & SILL REQUIRED ON WIDTHS GREATER THAN 30' ONLY DAY LIGHT OPG. DIMENSIONS TRUE COLONIAL WDW. D,L. OPENING MAX, WIDTH = 11' D,L. OPENING MAX. HEIGHT = 13- 7/16" • 53 1/8' WINDOW WIDTH 48 1/8" D.L OPG. (FIXED) ( GLASS TYP j - EE CHARTS( II II II 11 it I 48 1 /s'. D.L OPG. (VE.NT) 50 1/4' VENT WIDTH TYPICAL ELQ /ATION 1 OVER 1 TE51 UNIT N m 0 4" MAX. TYP. HEAD /SILL 2 Engr. OR. HUMAYOUN FAR004 STRUCTURES FLA. PE II 16557 OCT 1 6 2001 N d O J 0 TRUE MUNTINS CENTER ANCHOR AT HEAD & SILL REQUIRED ON WIDTHS GREATER THAN 30' ONLY EXPIRATION D fly 53 1/8" WINDOW WIDTH DSB -ANN. GL 5 (SS 11" D.L. OPG. 50 1 /4" VENT WIDTH TYPICAL ELEVATION TRUE COLONIAL TESTED UNIT NOTES., 1. THIS STRUCTURE IS DESIGNED AS PER THE SOUTH FLORIDA BUILDING CODE 1994 EDITION FOR DADE COUNTY. ALSO FOR WIND LOADS AS PER ASCE 7 USING CORRESPONDING LOADS. 2. WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. 3. ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. WINDOWS SHALL BE PROTECTED BY DADE COT N Y APPROVED IMPACT RESISTANT .3BUt`C.�ISS PRODUCT RENEWED nC+:EY A No. 0/ -'/O 2,3 • U 2 2� Z o06 / Pk.G1XJi TCONTROL DIVISION B'JILLINJ COI 'E ' 70M PLIFr'CE OFFICE 4" MAX. TYP. HEAD /SILL 0 0 z z LiJ O z N z_ 0 0 9 1 U ( ) 0 a 0 4) a) "c3 Q) .6 t7 0 c z U 2 ai z 0 Y CO 0 W 4 S V ) 0 T U drawing no. W98-25 sheet 1 of 5 MItiw1;7ADE MIAMI -DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING PRODUCT CONTROL NOTICE OF ACCEPTANCE Curv-A -Tech Corporation 930 W. 23 Street Hialeah ,FL 33010 Your application for Notice of Acceptance (NOA) of: Series 300 (S.T.D.) Aluminum Single Hung Window under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This NOA shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material- at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such product or material immediately. BCCO reserves the right to revoke this approval, if it is determined by BCCO that this product or material fails to meet the requirements of the South Florida Building Code. - The expense of such testing will be incurred by the manufacturer. ACCEPTANCE NO.: 01- 1023.02 EXPIRES: .11/12/2006 Raul Rodriguez Chief Product Control Division THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE This application' for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Miami -Dade County, Florida under the conditions set forth above. APPROVED: 01/24/2002 \x0450001 \pc2000 \\templates \notice acceptance cover page.00 Internet mail address: postmasterrXbuildingcodeonline .corn BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE [603 MIAMI, FLORIDA 33 13 0 -1 563 (305) 375.2901 FAX (305) 375.2908 CONTRACTOR LICENSING SECTION (305) 375.2527 FAX (305) 375.2558 CONTRACTOR ENFORCEMENT DIVISION (305) 375-2966 FAX (305) 375-2908 PRODUCT CONTROL DIVISION (305) 375 -2902 FAX (305) 372 -6339 Francisco J. Quintana, R.A. Director Miami -Dade County Buitding,Cgde Compliance Office Homepage: http : / /www.buildingcodeonline,com Curve -A -Tech Corporation ACCEPTANCE No.: 01- 1023.02 APPROVED: January 24, 2002 EXPIRES: November 12, 2006 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 1. SCOPE 1.1 This renews Notice of Acceptance (NOA) No. 98- 0513.06, which was issued on November 12, 1998. It renews the approval of a single hung aluminum window, as described in Section 2 of this NOA, designed to comply with the South Florida Building Code (SFBC), 1994 Edition for Miami - Dade County, for the locations where the pressure requirements, as determined by SFBC Chapter 23, do not exceed the Design Pressure Rating values indicated in the approved drawings. 2. PRODUCT DESCRIPTION 2.1 The Series "300" Aluminum Single Hung Window and its components shall be constructed in strict.compliance with the following document: Drawing No W98 - 25, Sheets 1 thro,ugh 5 of 5, titled "S -300 *Aluminum Single Hung `Window," prepared by Al Farooq Corporation, dated 3/25/98 and revised on 10/15/01, signed and sealed by Humayoun Farooq P.E., bearing the Miami -Dade County Product Control renewal stamp with the NOA number and expiration date by the Miami -Dade County Product Control Division. This document shall hereinafter be referred to as the approved drawings. .. 3. LIMITATIONS 3.1 This approval applies to single unit applications only, as shown in approved drawings. 4. - INSTALLATION 4.1 The aluminum single hung window and its components shall be installed in strict compliance with the approved drawings. 4.2 The installation of this product will require a hurricane protection system. 5. LABELING 5.1 Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance 6.1.2 Duplicate copies of the approved drawings, as identified in Section 2 of this Notice of Acceptance, clearly mark d to show the , :o.uhoii,;nts selected for the proposed installation. 6.1.3 Any other documents reuuire3 by the Building Official or the South Florida Building Code (SFBC) in order to properly evaluate the installation of this system., ± , 2 Raul Rodri ez, Clue Product Control_Division Curve -A -Tech Corporation ACCEPTANCE No.: 01-1023.02 APPROVED: January 24, 2002 EXPIRES: November 12, 2006 3 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS - 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami - Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; • b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed -the required documentation initially submitted is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process. b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purpose. 6. The Notioe of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The engineer need not reseal the copies. 8. Failure to comply with any section o ?t ii .c ep ance shall be cause for termination and removal of Acceptance. 9. This Notice of Acceptance consists of pages 1, 2 and this last page 3. END OF THIS ACCEPTANCE Raul Rodriguez, Chief Product Control Division WJNI OW 5CI- IEDULE MARK WIDTH -EIGHT MATERIAL CODE REMARKS A® 31' 38 3/8' GL /ALUM. el-I-23 SINGLE 1-IUNG WINDOIJ Q 31' 63' GL /ALUM. SN -25 SINGLE FLING WINDOW 14' 63' GL /ALUM. - NORIZ. SLIDING WINbOW Q 531/8' 38 3/8' GL /ALUM. 33 4 -1ORIZ SLIDING WiNI,OW ® EX181. WINDOW t0 REMAIN ® 53 26' , GL /ALUM. I 32 44ORIZ. SLIDING WINDOW 1 /4 • I - 0 ' 14' • D' -0• EXIST. DOOR TO REMAIN LJ - 1 _Ii I --- _ ; 1 1 I I I � - � 1 1 �; �1 I i � I IL SOUTH ELEVATION NOAH 01- 1023.02 +60, -60 31' X 63', 3/16' ANNEALED GLASS NORTH ELEVIATION EXIST. DOOR TO REMAIN OA* 02- 0221.05 +10, -10 31'x 383' EXIST. DOOR TO REMAIN El] 0 0 rum TT_ J__L1 1 L 1 _ � J —fir— i I H I, L 0 0 NOA* 03- 0801.06 +60 :1, -65 14' X 63', 3/16' TEMP. GLASS EXIST. DOOR TO REMAIN •OA* 03- 0801.06 +60.1, - 53 I'8' x 38 3/8', 3116' TEMP. GLASS EXIST. DOOR t0 REMAIN EXIST. DOOR TO REMAIN NOA 03- 0801.06 460.1, -65 14' X 63', 346' TEMP. GLASS �! I NOA* 03- 0801.06 +60.1, -65 53 1/8' X 38 3/8', 3/16' TEMP. GLASS NOAH 01- 1023.02 +60.1, -65 311X 63_',- 3116! ANNEALED_ GLASS EXIST. DOOR TO REMAIN NOAH 01 1023.02 +60, -60 31'x38 3/8', 3/16' ANNEALED GLASS If II if 11 ® v NOA 01- 1023.02 +60:1, - 31' X 63', 3/16' ANNEALED GLASS LLi n 1. _ _L La r � ! .�___j t� —jJ__- I a 1 1 1 11 11h1 I 1 I I 1 1 1 1 J I � a I 1 1 I I i ! H I 1 _ f lii i�iii i iPT i iii ii OA* 03. 0801.06 +60.1, -65 114' >63', 3/16' TEMP. GLASS 'i f i II IT 11 it iif EXIST. WINDOW TO REMAIN EX'13T. DDOOR/6IDELITE TO REMAIN NOAH 01 -1023. +60, - 60 31' X 63 3/16' ANNE NOA' 03- 0801.06 +60.1, -65 14' X 63', 3/16' TEMP. GLASS ED GLASS 7 Ii 0 C4 zz X 1• r NOA* 03- 0801.06 +601, -65 14' X 63', 3/16' TEMP. GLASS EA ELEv,ATION 1/ • ices , • • , 11 • • b ilbil aaaaaa • • • , • , , • , • , • , • • • • , , 11 , WET ELEV,ATION EXIST. DOOR TO REMAIN • • • • • • ,.•a. • • s • • it • II • ..•.. •••• ...... • •.,• • • ...... 0 00000 • • • • • • • NOA 03- 0801.06 +60.1, - 53 I/O" X 26', 346' TEMP. GLASS _LLLL'_L L_LL.LLLLLLLLLLLLL _L Lt_u_LL__LL LLLLLLLLLLLL _LLL_�L! LLLLLLLL_ _'_LL LLL L LL L L - LL—'LL! _ '_L_ LLLLLLLLLLLLL J _LL ! 1 LL_ _ J LLLL LLLLL___ L LLLL _LLLLLLLLLLLLLLL. �— EXIST. SCREEN BLOCK • • • • 1 • • • . •a • •• • • • • • ••aa • ••aa • • J • a 1 1 NOA 01- 1023.02 +60.1, -65 31' X 63', 3/16' ANNEALED GLASS • • J • • .3 • A A 10 �a@ 4 4itt DESIGN. DRAWN APPROV. DATE RO 01/ RO RO A -I ; :1 iTai'R' , • � 117 { -ifTt #' i'YXt f v MIAM N :3 V ILLA 3 E3UILOIN INSPECTION DEPAr27t.1EN APPILICATION r Of F3IJILOINc3 P MI`I' Application is hereby made for the appros al of the det, sled statemem of the plans and specifications herewith submitted for the build- ing or a h; - ructure her i described This fl licatic is made in compliance and con win ty w th the Building Ordinance of ?ilia ii Shores Vil.laee, or da, and all pro isions of the Laws of the State of Fh,rid. all o d nances Mi - m Shorts Village and all rules and reg - a'aran of the Building Div. r of .ram Shop silage b '1 e tpl ed with, whether herein specified or not. A copy of approved plans and specificati must be ket at banding durin, progress of the work. Owner' Name and Address STATE OF FLORIDA, COUNTY OF DADE. f ss. Disapproved (Signed) . -- Chairman Member Member - -- Council Approved Registered Architect and; or Engineer._ t Name nd address of licem-ed contractor. ____ Lt -y".k Q Location and legal description of lot to be built in: Lot. C - -- - Block - -- -- `,f Street and Number where work is to be done. Subdivision State work to be done and purpose of building (by floors) L)lstance to next nearest buildindt_ -' .Maximum live load to be borne by each floor !_/ built PLANNING BOARD Date /r, Date ' t . New Building. _ %� Remodeling To be constructed of_ __ _ _ Kind // ,C ofJouncjation Estimated' tal cost of improvements $_ / / /' s., Amount c` Permit $_ Zone --ubage required_ __ 0 0 , — Plan Cubage Size of Building Lot 1 submit all th 1 d be sent / The unde signed appli ant for th 's budding permit does hereby certify 'tat he understands of 1 bor under he Florida Workmen's Compensation Act be'nv S• - tion 5966 Cot p led Gun eren si �mr a :e plans an . s e isications for sa j All notic . with refe c and h s compl ed w'th -he prey' cons thereof, and will require s niilar comp lance from a' cont in the wok to be p ri •med under th s pun it and ill post or cause to be posted or •otices as are regmr d by the Act. The u. d. r rgn -d agrees to employ only suc permit as are licensed by M am. Shores \ ih, ge. Remarks (Signed) Member Member Member _. Disappros ed No. ` Street My Commission Expires_ DATE . A d d i t i o n _ _ No. of Stories Roof Coy ring / 0 -1 -_ X ._. /--2. 3 - to the building and its construction may and accepts hts _obligations as an employer al Laws of Florida P r anon S.,pplc rent, actors or subcontractors emplo ed by him on the site of the work so 1 pTablic note e , on work to be p - for f d . der this ' ,, 16 :. ° ; T. / /' Notary Public State of Florida . and for no other purpose. , ;,3 Before me, the undersigned authority, a notary public, duly authorized to adm.nister oaths c.nd take acknowledgments, personally ap- peared to me well known, and who, being by me first d. ly sworn, upon oath deposes and says that he is the of th ahoy de c. ibed :struction t. . It has carefully read the foregoing application, and that he did sign the same, and that all facts therem by him stated are tr Permit No `.,� i /k'J - _ Date__ � Read, Sworn to and Subscribed before me. \ Date_ Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application ftt r approval lr .s Leer obtained from the Flom ng Board A re-inspection fee of $1.00 sill be charged when such re- inspection is rn lie necessary by improper notice for inspe - -t or fa. , ty materials and /or workmanship. • ° `: 01 , ;.� E`� �/ '--�� • �°' " � , f ' 1 t 011 ) (t t) t ` l , • 01 1 c° < t � 4 -w- ()QAD __= 4 C` (7` (`9