Loading...
934 NE 91 Terr (4)Inspection Number: INSP - 14298 Inspection Date: 06/07/2006 Inspector: Desharnis, George Project: <NONE> Contractor: HOME OWNER Building Department Comments Tuesday, June 6, 2006 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 7 ENT11 Owner: STOKESBERRY, JOHN Job Address: 934 91 Terrace NE Miami Shores Village, FL 33138- Block: it Number II' -4-06 -892 Permit Type: Fence/Wall Inspection Type: Final Work Classification: Wood Fence Phone Number (305)758 -5849 Parcel Number 1132060030140 Lot: Page 1 of 2 Passed Inspector Comments 6t-fr1/24.,_,Z i / ` C_ , i ct .._. 7, Q, Failed Z Correction Needed _____ Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Number: INSP - 14298 Inspection Date: 06/07/2006 Inspector: Desharnis, George Project: <NONE> Contractor: HOME OWNER Building Department Comments Tuesday, June 6, 2006 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 7 ENT11 Owner: STOKESBERRY, JOHN Job Address: 934 91 Terrace NE Miami Shores Village, FL 33138- Block: it Number II' -4-06 -892 Permit Type: Fence/Wall Inspection Type: Final Work Classification: Wood Fence Phone Number (305)758 -5849 Parcel Number 1132060030140 Lot: Page 1 of 2 Issue Date: 4/18/2006 Owner's Name: JOHN STOKESBERRY Permit Type: Fence/Wall Work Classification: Wood Fence Job Address: 934 91 Terrace NE Miami Shores Village, FL 33138- Contractor(s) HOME OWNER Expires: 04/07/2007 Phone Primary Contractor Yes Comments: REPLACE EXISTING CHAIN LINK FENCE WITH A WOOD FENCE Additional Information Type of Construction: Wood Fence Classification: Residential Additional Info: In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. Fees Due CCF Education Surcharge Notary Fee Permit Fee - Wire & Wood Scanning Fee Technology Fee Total: Building Department File Copy Amount $1.20 $0.40 $5.00 $240.00 $3.00 $6.00 $255.60 Applicant Signature Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Permit Parcel #: Block: Section: Permit Status: APPROVED Permit Number: FW -4 -06 -892 Phone: (305)758 -5849 1132060030140 Lot: PB: Total Square Feet: 240 Total Valuation: $ 2,000.00 Required Inspections Foundation Final Invoice Number FW - 4 - 06 - 24510 Total: Amt Due $255.60 q °\°/ c Amt Paid NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county. AND THERE MAY BE ADDITIONAL PERMITS REQUIRED FROM OTHER GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT DISTRICTS, STATE AGENCIES, OR FEDERAL AGENCIES. Type of Work: Describe Work: BUILDING PERMIT APPLICATION FBC 2001 BY: Job Address (where the work is being done) City Miami Shores Village Is Building Historically Designated Submittal Fee $ Notary $ Scanning $ Code Enforcement $ Total Fee Now Due $ (Continued on opposite side) Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: 305)795.2204 Fax: 305g56.8972 MCMEW APR 0 7 2006 County YES NO Structural Plan Review. $ Permit Type (circle): Building Electricca ° l [ Plumbing Mechanical Roofing Owner's Name (Fee Simple Titleholder) 0 S l o ' sD Grr( Phone #(30.0 7s Owner's Address g 3 Lf N Cit l a V) L S State FL. Zip 3 7 j ` 3 O Tenant/Lessee Name Phone # -- 934 Ng qy rnac, Nl to u Sitoces /L 53136 Miami -Dade X 4 lg)o ) , f•-1 e s sA cr g Permit No. fUj Q( — X17 Master Permit No. Zip Contractor's Company Name IVA d(JAJ Phone # Contractor's Address City State Zip Qualifier State Certificate or Registration No. Certificate of Competency No. Architect/Engineer's Name (if applicable) //"1 n Phone # $ Value of Work For this Permit 2000 U Square Footage Of Work: ;140 Li i ❑Addition ❑Alteration ['New Repair/Replace ❑ Demolition Ref tace_ eXr517 n � c c ;car hh k -FenCe. wit a woad fence * * * * * * * * * * * * * * * * * * * * * * * * * * ** Fe * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Fee $ 2,q6 - CCF $ Training/Education Fee $ Technology Fee $ Radon $ Zoning Bond $ CO /CC Bonding Company's Name (if applicable) N/A Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) N /A Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Owner or Agent The foregoing instrument was acknowledged bef e me this 7 day of Contractor The foregoing instrument was acknowledged before me this 20 1 by3Onn ¶ ( ' ,� t e3oevyr day of , 20 — by who is personally known to me or who has produced =r- who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY P Sign: Print: mission )11'11 My Com ission Expires: ded I. My Commission Expires: APPLICATION APPROVED BY: chc 05/13/03 Signature Sign: Print: OVCf- Plans Examiner Engineer Zoning VILLAGE OF MIAMI SHORES OWNER BUILDER DISCLOSURE STATEMENT NAME: 7 660 S Oick55 • DATE: ADDRESS: 7 3y ! ! Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, F.S 489.103(7). And I have read and understood the following disclosure statement, which entitles me to work as my own contractor; I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor. You have applied for a permit under an exception to the law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the construction yourself. You may build or improve a one - family or two- family residence. You may also build or improve a commercial building at a cost of $25,000.00 or less. The building must be for your own use and occupancy. It may not be built for sale or lease. If you sell or lease a building you have built yourself within one year after the construction is complete, the law will presume that you built for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person as a contractor. It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F.I.C.A and with- holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable law,, ordinances, buildings codes and zoning regulations. Please read and initial each paragraph. 1. I hold title to the above property and I am planning on doing this construction Initial 2. I understand that as an owner- builder I must abide by all zoning ordinances and building regulations in effect at the time of permit application Initial 3. .I have an understanding of the 2004 FBC & FRC and understand that this department and its inspectors are there to help enforce and interpret the code. There is a copy of the code in this office for review. 4-% 1 4. I understand that the building official and inspectors are not there to design, alter or give advice on how to meet code —. only if the structure meets the minimum code. Initial Initial 5. I understand that as an owner - builder, that any contractor disputes with sub- contractors and myself must be handled in a civil court with the advice of an attorney. The department will not mitigate contract disputes. 6. I understand that if I compensate any person or company for work performed they are required to have a business license in the county. If for any reason they do not posses a business license I will be responsible and liable for any wrong doing from this unlicensed company or person. 7. I understand that if any person gets injured on my construction project —they are entitled to workmen's compensation. And if they do not posses a workmen's policy I could be held liable for all doctor and related cost which could include loss of wages during recovery from injury. Was acknowledged before me this 0 day of Produced there License or 0 Initial Initial Initial 8. I understand that under state and local laws I can not do any Electrical, Plumbing, Heating, Air & Roof work on my property with out first obtaining the proper permits by licensed contractors. I , 20 O Co . By Thfn ' k e S O;rr ho was personally known to me or who has as identification. NOTARY „4„;','4„ iy abel Va rded i. AtIa, itic Rondine Co.. Inc .t9 and completion of all elen'enfs rrrr r r r rrr r The following items will be checked at final Inspection: ••• •• i, • •••. • - • • : fir t Crr • r. :1: • ootl, feddc6s. shallt4. c nstructed. of decay and tetrrniite. ;..esistant:rinateria l- a_oecified. in-Section. . •. X304.2;1 q the Ef ri Building Code (FBC). r r r ' • • Wood fences shall be designed according to the loads as specified in Section 2328 of the Florida ldfng e0dC g j • < . r: r r r n r • ••••••. • • E idEIST')0' L3nfe►ss designed by rational analysis, ,vvoo I ferrco 'ii4t pxcpecJing six Cfeet in height may be constructed to meed the following minimum requirements: 1. Vertical post of P.T. 4" x 4" spaced according to Section 2328.2.4 FBC. See detail on front page; 2. Posts shall be embedded two (2) feet into a concrete footing ten (70) inches in diameter; 3. Horizontal framing shall consist of a minimum of three (3) horizontal rails of 2" x 4" Pressure Treated (PT) Ilumbvr, 4. All lumber shall be a minimum of #2 grade or better; S. All - fasteners shall•be corrosion r- esistant. WARNING: Premanufactured sections may not comply with this code, and Produce Approval may • be required: 0 Stockade • • • Nona() uiioing Loae irf rr r • ••• • • • ••• , V�lood fences • • • • • • '. • • .••.•. • . •r • • • • • • • • • • • • Sec. 1611.2.1 Fences. Fences not exceeding 5 -0" in height from grade may be designed for 75 mp (33 m/s) fastest wind sPeed pr .90 4nph ! 40 m/s) 3,second gust. • • • •• • • .. r. r n n r n r r n • • ' • • • • • • • • • • • • • • r r r r r r n r • • • • • • •' • • • • • • • • • • • • ••• • • • • • • • Sec. 1611.2.1,1 Wood Fehc�s. Waod'fnce , d esi jn shall be as specified by 2354.: ' • ' • • • Sec. 23_28.2 . 4" c r Post Spacing - X i re �l I, butt AVOWED 5 ' rr r w Fences < = 5 ff. High - 5 if On Center Fences < = 4 ff. Hi o h - 6 ft. On Center 2x4 Horizontal. Wood. Members. •• • • • •• .. • • .. ••• • • • • • • • ••� . • • • • • • • • •' • • • • Section 2328.2 Nominal 4x4x8 posts No.2 Grade or better. embedded 2 f Into concrete footing 10 Inches In diameter and 2 feet deep._. Sec. 2326.2:10 All posts, .poles and columns embedded In concrete wh ch Is n and supporting permanent structures shall be approved pressure treated wood contact use except naturally durable wood may be used for posts, poles and c concrete for structures other than buildings and walking surfaces or In structures above ground level and not exposed to the weather. Sec. 2326.2.6 The expresslonl'naturally durable wood" refers to the heartwood species...: 1. Decay resistant- Redwood; Cedars; Black Locust 2. Termite resistant - Redwood, Eastern Red Cedar, Sec, 2324.2 Nails, bolts and other connectors that are used in locations exposed fo the weather shall de galvanized or otherwise corrosive resistant. Sec. 2324.3 In general, nails shall penetrate the second member a distanc equal to the thickness of the member being nailed thereto. There shall be not Tess than two nails in any connection. Nail Sizes: 4d: 1-1/2" long 6d: 2" long 8d: 2-1/2" long 3" long 12d: 16d: 4" long contact with .ground suitable for ground olumns embedded In where wood Is of the following 5'-O" MAX 2' -0" Owner's Side —I'-0" APR 0 7 2006 Wood Posts 2" X 4" Wood Ball 4' -0" High or Less = 6' -0' O.C. 5' -0' High or Less = 5' -0" O.C. I" X6" cr I" X63" Wood 7 Ickets Concrete III WOOD FENCES 3' -0" 2915 Fences • • • • • . . .• ........ ... ... . . : • • • ••• • •• • • • • • •• . .. .. ... . . . . . . • . .. .... • • • • • • • • ••• • • • ••• •• •• • • • •• •• • • • • • • •. • • • • • • • • • • • • • •• • • • • ••• 2915.1 Wood fences, so located on a property that by zoning regulations they cannot be used as a wall of a building, shall be constructed to meet the following minirnum specifications. (a) Fences not exceeding 5 feet in height shall be constructed to meet the following minimum requirements: from nominal 4 inch by 4 inch by 8 feet -0 inch long posts spaced. 5 fee.-0 inches on centers, having a fiber stress of 1200 p.s.i. in bendinc,, and shall be embedded 2 feet -0 inches into a concrete footing 1 fcot -0 inches in diameter and 3 feet -0 inches deep. Other components shall be designed to comply with the provisioqs of. this Chapter and Chapter 23. (b) Fences not exceeding 5 feet and 4 feet in height respectively shall be constructed as provided in paragraph 2915.1 (a) herein, except that the spacing of posts may be increased to 5 feet -0 inches and 6 feet -0 inches on centers for these heights. 0.20' CLR. - FD. I.P. 0.45' N PIPE SIGHtED e5. 0.01' 6... CLR. 0.05' GARB CLR. =/--- BOX O to 4 4' AG 2.8' rn rn F WD. POLE X9.35' •• ••• •• • • • •• • • •• • • • • • • •• ••• • • CONCRETE: DRIVEWAY • • ••• •• • � . . . . • • ... • • • . • •• • . . ' ,e • . • • • ••• • • .. . • • • . • . .. . • • • • • • •• • . • -�-11 • • • • • C . 9.1 s STREET 23.85' • 6.42' CONCRET CI) • POOL • • •• /19.41'/ 129.15' 15.64' to ao c1 N / 1.21 1 STY C.B.S. #934 ,30.75' IN `•h 3.0 129.41 n� to p U 9. 8.0 - 3.10' ri /18.3 0.7' BRICK WD. DECK 3' C.B.S. WALL 0' WD. DECK 10.1 HEAT PUMP POOL PUMP ALUMINUM SHED 40.32' s pc O to N 7.56' 7.56 1.55' EI�1C, 0.33' CLR. SET CONC. NAIL 8 ICK B.B.Q. 0 0 0 25' 25' z 61.2' (o 11 53.0' 10 (O in • 8 25' 53.03' 53.06' 23.45' crz 0 0 0 Iii /66.77' A. R. TOUSSAINT & ASSOCIATES, INC. LAND SURVEYORS FLORIDA CERTIFICATE OF AUTHORIZATION NO. LB -273 620 N.E. 126 ST. NORTH MIAMI, FLORIDA 33161 FB: 354 PGS: 66 -67 DATE: JUNE 22, 1988 ORDER No. 9150 SCALE: 1" = 20' REVISED THIS 8th DAY OF SEPTEMEBER 2003 TO BRING THIS SURVEY UP -TO -DATE REVISED THIS 8th DAY OF NOVEMBER 2005 TO BRING THIS SURVEY UP -TO -DATE ORDER: 13856 � gCMIIC�Ig D APR 0 7 1066 loco AC1 B Y: CI �' N.E. 91st TERRACE . •• • . •. . i • • • . • . • • • • • ••• • • • • • • • • • • • • In n lo • 5 • , in N •4 ••2 •3•� • •• • • • • n • ••• • • • • • • • • • • • • • • • • • • ••• • 1 '• • • ••• •o A.C. = C.B.S. — c.0. = CONC = ENC. = FD = IP Ls = WM = LOCATION MAP crAl r: 1 •= 1 00 LEGEND: 53.E ' • • • • • 53.06' m n •• AIR CONDTf10NER CONCRETE BLOCK STUCCO CLEAN OUT CONCRETE ENCROACHMENT FOUND IRON PIPE PROPERTY UNE REGISTERED LAND SURVEYOR No. WATER METER • • . 125.0' o • • • • 0 2 125.13' BY; Lli ALBE17T R. TOIISSAINT REGISTERED EMCINEER NO. 8939 REGISTERED IAND SURVEYOR NO. 907 STATE OF FLORIDA 0 0 0 m 35 -- ' z 35' 0 Ln 35' 35' LEGAL DESCRIPTION: SURVEY OF THE WEST 7.56 FEET OF LOT 6 AND ALL OF LOTS 7 AND 8, BLOCK 2, OF 'BISCAYNE RIDGE, ACCORDING TO THE PLAT THEREOF RECORDED IN PLAT BOOK 39 AT PAGE 41 OF THE PUBLIC RECORDS OF MIAMI -DADE COUNTY, FLORIDA, BEING SITUATED IN THE VILLAGE OF MIAMI SHORES, FLORIDA. SURVEYOR'S CERTIFICATION: WE HEREBY CERTIFY THAT THIS SURVEY IS TRUE AND CORRECT TO THE BEST OF OUR KNOWLEDGE AND BELIEF AS RECENTLY SURVEYED AND PLATTED UNDER OUR DIRECTION AND THAT THIS SURVEY COMPLIES WITH THE MINIMUM TECHNICAL STANDARDS FOR LAND SURVEYING IN THE STATE OF FLORIDA, UNDER CHAPTER 61G17 -6 FLORIDA ADMINISTRATIVE CODE, CHAPTER 472.07 FLORIDA STATUTES. NOT VAUD WITHOUT THE SIGNATURE AND RAISED SEAL OF THE REGISTERED LAND SURVEYOR SHOWN HEREON. A.R. TOUSSAINT & ASSOCIATES, INC. PRES. 25' 25' 25' 25' 0 0 0