RF-11-417Inspection Number: INSP - 157006 Permit Number: RF -3 -11 -417 Scheduled Inspection Date: April 29, 2011 Inspector: Bruhn, Norman Owner: Job Address: 555 NE 87 Street Miami Shores, FL Project: <NONE> Contractor: DALEY ROOFING INC Building Department Comments Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Permit Type: Roof Inspection Type: Final Roof Work Classification: Flat Phone Number Parcel Number 1132060200970 Phone: (305)754 -9892 RE -ROOF FLAT ROOF Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments April 28, 2011 For Inspections please call: (305)762 - 4949 Page 8 of 16 3j1011- BUILDING PERMIT APPLICATION FBC 2004 Permit Type (circle): Building / Owner's Name (Fee Simple Titleholder) it /J v / jC.ta /AJ` /S Phone # Owner's Address /5/5 4/t't City / / State 4 Zip - 3J Tenant/Lessee Name Phone # Job Address (where the work is being done) 555 /L (9 `v "1 City Miami Shores Village County Miami -Dade Zip 33/ FOLIO / PARCEL # -32o to - '00 2 0 _ -70 Is Building Historically Designated YES NO //". Contractor's Company Name ) /Ley /Z O i'/ j /A)C-- Phone # 305 75V 9(12 Contractor's Address '7( ALE /c la p City /1.-//1.-///1124/ i //9?/ . ,1—CTS State Zip 33)30 Qualifier Name b/41\/ / 691-614 Phone # State Certificate or Registration No. �5-t%t J / I �J Certificate of Competency No. Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $ c q, 76v Type of Work: ❑Addition Describe Work: ❑Alteration ❑New t L i : * : * * ** * * * * * * * ** * * * * * * * ** * *** Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 X Repair/Replace MAR 082011 iI Permit No. C 1 1 9 „ 1 - 1 Master Permit No. 04 32(' 9,301 Square / Linear Footage Of Work: J 024. -S(r. ❑ Demolition * * * * * * ** F * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Submittal Fee $ Permit Fee $ ®� CCF $ CO /CC Notary $ Training/Education Fee $ Technology Fee $ Scanning $ Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature !° Owner or Agent The foregoing instrument was acknowledged before me day of 20J_, by ;" ‘' who is personally known tome or who has produced As identification and who did take an oath. NOTARY PUBLIC: (Revised 07/10/07) „ OTARY FL'BLI -FATE OF FLORIDA Signature Contractor The foregoing instrument was acknowledged before me this day of Nl A RCN , 20 1 1 , by who is personally known to me or who has produced as identificatiorondti ►o /1} }d take an oath. NOTARY PUBL \ \\ Ere Sign: ' : � ` ' � Sign: '� _ Print: t �� It�..,,� 1, t Print: ��������g�ti �� • My Commission Expires: `u~+' ;Commission #DD632826 My Commission Expires:' / /, ��� S TA T E �� , � ,,,, , ,,. Expires: FEB. 24, 2011 // APPLICATION APPROVED BY: -F /V ` Plans Examiner Engineer Zoning NOTICE OF COMMENCEMENT A iUECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT Nate 3 -//- ` I irAX FOLIO NO. STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement 1. Legal description of property and street/address: 2. Description of improvement - J i 9T goof 3.Owner(s) name and address: Interest *in .property: Name and address of fee simple titleholder: 4. Contractor's name, address.and phone number Section 71.3.13(1)(a)7., Florida Statutes, Name, address and phone number. Signatures) of Owrif Own Owner(s)' Authocer /Director/Partner/Manager , Prepared By , - ��i- _ Prepared By • r Print Name- .+�G R• l Z- 2 - Print Name > 1 L'.' Title/Office 1/c Title/Office STATE OF FLORIDA COUNTY OF MIAMI -DADE fd The foregoing insti was ackn wledged before me this l4 ay of By . .l0 !-�i�t t G4`�K00' • `Z �i or [211 as for U6 Personally known, or 11 produced the following type of identlflcatio Signature of Notary Public: Print Name: (SEAL) VERIFICATION PURSUANT TO SECTION 92,.525. FLORIDA STATUTES Under penalties of perjury, I declare that i have read the foregoing and that the facts stated in it are true, to the best of my knowledge and belief. , ,,,,,,, Expires: FEB. 24, 2011 BONDED THRUATLANTIC BONDING CO, INC. Signature(s) of Owner(s) or Owner(s)'s 1' d Officer/ Director /Partner/Manager who signed above: By NOTARY PUBLIC. STATE OF FLORIDA / ' 4. '° G. Budwick I,� :ComE. mission #DD632826 1111111111111111111111111111111111 CFN 2O11R01 7a 6 OR Bk 27622 Fs 0107; Ups) RECORDED 03/18/2011 12:20:22 HARVEY RUVIW, CLERK OF COURT I°IIAI`1I —DACE COUNTY? FLORIDA LAST PAGE Space above reserved for use of rig office . !N � 75� qtql. 5. Surety. (Payment bond required by owner from contractor, ff any) Name, address and phone number. Amount of bond $ 6. Lender's name and address; 7.: Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Uenor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name, address and phone number. A J 1 9. Expiration date of this Notice of Commencement: (the expiration . date Is 1 year from the date of recording unless a different dateis spy WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN "RESULT iN YOUR PAYING TWICE =FOR IMPROVEMENTS TO YOUR PROPERTY! A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE - ; 's FiRST INSPECTION. iF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMM " - " • - OR RECORDING YOUR NOTICE OF COMMENCEMENT. w 3 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES on SUBJECT TO COMPLIANCE WITH ALL FEDERAL TE AND COUNTY RULES AND REGULATIONS Florida Building Code Edition High - Velocity Hurricane Zone Uniform Permit AppU Master Permit No oy�l � Process No Contractor's Name 0446 �® /t�67 / C ' Job Address 5 t7 spr ° NdLow Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tile MAR 0 82011 ❑ Asphaltic ❑ Metal Panel/Shingles ❑ Wood Shingles /Shakes 8 Shingles ❑ Prescriptive BUR -RAS 160 ROOF TYPE ❑ New Roof ❑ Reroofing ❑ Recovering ROOF SYSTEM INFORMATION ❑ Repair 0 Maintenance Low Slope Roof Area (SF)S2030 Steep Sloped Roof Area (SF) Total (SF) boo ,Sertinn R (Rnnf Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets• Notice of Asbestos Form Type of Notice (check one) igr ORIGINAL ❑ REVISED ❑ CANCELLATION 0 COURTESY Type of Project ❑ DEMOLITION 0 RENOVATION It ROOFING 0 ROOF OVERLAY (NO EXISTING ROOF MATERIAL TO BE DISTURBED) L Facility Name: Address City Site Building Size Prior Use: Present Use: Florida Department of Environmental Protection Division of Air Resource Management NOTICE 's: , F ; /) VATION OR DEMOLITION IF DEMOLITION, WAS IT AN ORDERED DEMOLITION IF RENOVATION: IS IT AN EMERGENCY RENOVATION OPERATION? IS IT A PLANNED RENOVATION OPERATION? N1i3i S 1+p jL M 11. Facility Owner: Address City III. Contractor's Name: State (Square feet.) No. of Floors ❑ School/College/Univ. ❑ Residence ❑ School/College/Univ. 0 Residence Surveyed by.. Zip�l�✓�1 PAD V 1-F0 L aw s M State MIAMMAID Ori "Delivering Excellence Every Day" Division of Environmental Resource Management Air Section 701 N.W. First Court Sth Floor Miami, Florida 33130 -1540 ❑ YES ❑ NO ❑ YES ❑ NO ❑ YES ❑ NO Age in Years ❑ Small Business ❑ Small Business Other Phone No. -ri- Zi File # Process # • County Phone No.,4 I- - ' Address 1 . 7 k ift. 1 ot,,,, s City M ifavi I 51+0 State . _. a I Z' • i t Florida License # (FM-M7 Is the contr. exempt from li licensure under section 469.002(4) F.S. ❑ YES 1 - 1 Other Tern NO Notice of Asbestos Form IV. Scheduled Dates: Asbestos Removal ( mm/dd/yy): Start Date / / Finish Date Demo/Renovation (mm/dd/yy): Start Date f l / / fl Finish Date f / D / D V. Procedures to be used (Check All That Apply): ❑ Strip & Removal ❑ Glove Bag ❑ Bulldozer ❑ Wrecking Ball ❑ Wet Method ❑ *Dry Method ❑ Explode ❑ Bum Down Other 1� I * MUST OBTAIN PRIOR DEP APPROVAL BEFORE USING A DRY METHOD VL Procedures for Unexpected RACM: VII. Asbestos Waste Transporter: Name, Phone No Zip City VIII. Waste Disposal Site Name: Class Address IX. Amount of RACM or ACM Square feet of surfacing material Linear feet of pipe Cubic feet of RACM off facility components Square feet of cementitious material Square feet of resilient flooring Square feet of roofing I certify that the above information is correct and that an individual trained in the provisions of this reguladon (40CFR Part 61, Subpart Al) will be on -site during the demolition or renovation and evidence that the required training has been accomplished by this person will be available for inspection during normal business hours. an of Owner / Operator / PRINT or TYPE Signature of Owner / Operator DERM USE ONLY: Postmark / Date Received l l /El in PLAN REVIEW HNAL PP OVAL DEPARTMENT OF ENVIRONMENTAL RESOURCE MANAGEMENT Ci CORE REVIEWER (PRIM). SIGNATURE L / DATE a it I State Date lLJ S X. Additional Comments Signed Contact Ph. Mec/c* (Yo2 ¢, o4o Itp IAWI1 -DADS D.E.R.M. AIM QUALITY MANAGEMENT DIVISION This i3 to certify that the required Notification(s) Regarding asbestos have been submitted in Com.liance with olio- - regula s FIU In specific roof assembly components and Identify manufacturer (If a component is not used, Identify as "NA ") System Manufacturer: £ r Product Approval No. *9y d dgL/, co) . Z Design Wind Pressures, From RAS 128 or Calculations: Pmax1; 5 , Pmax2: Si 1 Pmax3: l 3I Max. Design Pressure, from the spo Product Approval system. Deck. " WWQ Gauge/Thickness: Nil rf ruw Slope: Anchor/Base Sheet & No. of Ply(s): Anchor/Base Sheet Fastener/Bondi "Material: Insulation Base Layer: Base Insulation Size an Witness: Base insulation /Bonding Material: Top insulati, Layer. Top 1 , atlon Size and Thickness: To insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): 1 D ! Bt t a M erifti ttatt ng ! 'f1�LAS Ply Sheet(s) & No. of Ply(s): Ply Sheet Fastener/Bonding Material: e i tl Top Ply: i O I>7 ( 3 �'I(✓ Top Ply Fastener/Bonding Ma FLORIDA BUILDING CODE — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2004 High- Velocity Hurricane Zone Uniform Permit Application Form. Surfacing: 1(4# Fastener Spacing for Anchor/Base Sheet Attachment: Field: 7" oc Q Lap, 11 Rows ? @ q " oc Perimeter. " oc 0 Lap, 8 Rows 0 " oc Conner: " oc 0 Lap, # Rows K e W " oc Number of Fasteners Per insulation Board: Field Perimeter Comer Illustrate Components Noted and Details as Applicable: Woodbiocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter Ong; Etc: Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener 'type, Fastener Spacing or Submit 1523 Roof System Manufacturer: Notice of Acceptance Number: CaMinimum ti Design Wind Pressures, If Applicable (From RAS 127 or lcula P1: P2: P3: Maximum Design Pressure (From the Product Approval Specific System): ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Roof Slope: : 12 Ridge Ventilation? Mean Roof Height Deck type: Type Underlayment Insulation: Fire Barrier: Fastener Type & Spacing: Adhesive Type: 15.34 Florida Building Code Edition 2004 High-Velocity Hurricane Zone Uniform Permit Application Fpm: Section D. (Steep Sloped Roof System) FLORIDA BUILDING CODE -- BUILDING 0 M I A M bD MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130 -1563 (305) 3152901 FAX (305) 375 -2908 NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF RUBEROID Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 07- 1203.01 and consists of pages 1 through 31. The submitted documentation was reviewed by Jorge L. Acebo. APPROVED! NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 1 of 31 Membrane Type: APP /SBS Heat Weld Deck Type 1: Wood, Non - insulated Deck Description: 19 / 32 " or greater plywood or wood plank decks System Type E(2): Base sheet mechanically fastened. All General and System Limitations shall apply. lire Barrier: FireOutTM Fire Barrier Coating, VersaShield Asphaltic F -Based (optional) Underlayment or SecurockTM. Base sheet: GAFGLAS #80 ULTIMATM Base Sheet, STRATAVENT EliminatorThl Nai'able, RUBEROID Modified Base Sheet, RUBEROID MOP Smooth, RUBEROID 20, RUBEROID SBS Heat- WeIdTM Smooth or RUBEROID SBS Heat-Weld 25 base sheet mechanically fastened to deck as described below•, Fastening Options- GAFGLAS Ply 4, GAFGLAS Flex PIyTM 6, GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field • (Maximum Design Pressure -- 4Spsf, See General Limitation #7V GAFGLAS Ply 4, GAFGLAS Flex PIyTM 6, GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill -TecTM AccuTrac Pla 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. Maim= Design Pressure — 45 psf, See General Limkation #7) GAFGLAS Flex PlyTM 6, GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure S2S psf, See General Limitation #7) GAFGLAS #80 ULTIMATM, RUBEROID ® 20, RUBEROID Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure — 60 psf, See General Lion #7) GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with Drill-Teen" #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Mai:imum Design Pressure — 60 psf, See General Limon #7) Any of above Base sheets attached to deck approved annular ring shank nails and 3" inverted Drill -TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. ( Maximum Design Pressure -60 pay; See General Lhnjion #7) NOA No.: 09-0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 29 of 31 GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with Drill -Term #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure - 75 psf, See General Limon #7J Ply Sheet: (Optional except over RUBEROID Modified Base Sheet, RUBEROID MOP Smooth, RUBEROID 20, RUBEROID SBS Heat WekdTM Smooth or RUBEROID SBS Heat- WeIdTM) One or more plies GAFGLAS PLY 4 or GAFGLAS Flex PIyh 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate Of 20- 40lbssq. or RUBEROID Torch Smooth torch applied according to manufacturer's application instructions. Membrane: One ply of RUBEROID Torch Smooth, RUBEROID Torch Granule, Roof Match"' APP Torch Granule, RUBEROID EnergyCapTM Torch Granule FR, RUBEROID Torch Plus Granule, RUBEROID EnergyCapm Torch Plus FR, or RUBEROID Torch FR torch applied according to manufacturer's application instructions. Or One or more plies of RUBEROID SBS Heat We1dTM PLUS, RUBEROID SBS Heat We1dTM PLUS FR, RUBEROID SBS Heat-Weld"( 170 FR, RUBEROID EnergyCapTM SBS HeatWeldTM Plus FR, RUBEROID SBS Heat- WeldTh, RUBEROID SBS Heat We1dT' Smooth, RUBEROID ULTRACLAD SBS and RUBEROID SBS Heat- Weld"( 25 applied according to manufacturer's application instructions. Surfacing: (Optional, required if RUBEROID MOP Smooth or RUBEROID 20 is top membrane) Install one of the following 1. Gravel or slag applied at 400lbssq. and 300 lbs.sq. respectively in a flood coat of approved asphalt at 60 lbsfsq. or applied in a flood coat of Leak Buster"' MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS Mineral Surfaced Cap Sheet, GAFGLAS Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 401bsJsq. 3. Leak BusterTM Matrix"' 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak Buster"' Matrix"' 715, Leak BuSterTM MatrixTM 322, TOPCOAT MB +, TOPCOAT Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote roof coating applied at 1 to 1.5 galJsq. 6. TOPCOAT Surface Seal, TOPCOAT Fireshield SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 gal./sq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: i APPROVED 1 See Fastening Above NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 30 of 31 WOOD DECK SYSTEM LIMITATIONS: 1 A slip shat is required with Ply 4 and Flex Ply ' 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 'A" Dens Deck or 'A" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of - 45 pst 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 2751bf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure vanes (i.e. perimeters, extended comers and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 31 of 31 • TGFU,R1305 - Rooting Systems Primer: — "Fire Our applied at 1- 0e1 Base Sheet — One ply Type 02 "GAFGLAS d75 ease Sheet", or ern -Pit #75 Base Sheet ", me:hantcally fastened. Membrane: — "Ruberoid Torch Granule cr - Rubermd Torch Granule 1" or "Reberaid Torch Granule Piss" or "Rubel J4 Torch FR" heat fused. 50. Dealer C -15/32 1redMet 1/2 51. Dade NC Inclirne: 1/2 Insulatton (Optianal)r Min 1/2 M. wood fiber, mechanically fastened. Sap Sheet (Optienal)t -1 ply "StormSafe" mechanically fastened. Base Sheens — One ply "Liberty $B$ Self - Adhering Base/Ply Sheet° or "Ruberoid SA Base/Ply Sheet" self adhered. Membrane: — One ply "Ruberold SBS Heat Weld 170 FR' or "Ruberold 30 FR" or `Rub:mold EnergyCap SBS 30 FR' or "Rube:fold SBS Heat Weld Pius FR" heat fused. 52. Deck: C-15/33 Incline: 1/2 53, Deck: NC borne: 1 56. Vedas NC Printer: -- "Fire Out" applied at 1- Dal /1004: Ba a tt — One ply Type 02 "6AFGL 4S ar75 Rase Sheet ", or "TrI -Ply #75 Base Sheet ", mechanically fastened. Fly Sheet (Optionsal)r — One ply Type G1 or Type G2 mechanically fastened. Membrane: — ° Ruberoid Torch Granute#"or "RuDereld Torch Granule 1"or °Rub/void Torch Granule Plus "or "Ruberoid Torch FR° heat fused. Insulation (Optimal): — Any UL Oassified, any thickness, mechanically fastened. Barrier Board: — minimum 1 /2 -in. thine annum board or minimum t t4 -in. thick G -p Gypsum Corp - 0ensbeck ® Roofboard" or "DenaDeck Prime@ Roofbeard" or "DensDeck DuraGuard ' knofboard" mechanically fastened. Bate Sheet: — One ply "Liberty 555 Self- Adhering lase/Ply Sheer or "Ruberoid SA Base/Ply Sheet" eelf adhered. Membrane: — One oly "Ruberoid SBS Herat Weld 170 FR° or "Ruberold 30 FR" or - Ruberold Energyeap SW 30 FR' er "Rubyroid S55 Heat Weld Pius FR" heat fused. Primer — °Fire Out applied at 1- gel/10O -ft Base Sheet (Optional): — One ply "iibetty MA Base Sheer, mechanically fastened. Ply Sliest: — One ply "Lbety SBS Self Adhering Base/Ply Sheol" or "Ruberotd SA Sase/Piy Sheet" self adhered Cap Sheet: — One ply "Liborte FR 655 5eif- Adhering FR Cao Sheet° or "Reberotd SA Cap FR sneer self adhered. 54. Deck: C -15/32 Incline: 1/2 Primer: — "Fire Our apses at 1- gal /100 -ft Slip Sheet (Optional): — 1 ply "StormSafe" mechanically fastened. Base Sheet (Optional): — One ply "Liberty MA Base Shed", r ecnen easy fastened. Ply Sheen -- One ply "Liberty 58S Self- Adhering Bose/Ply Sheet or "Ruberoid SA Base/Ply Sheet" self adhered. Cap Sheet — One ply "Liberty FR S85 gel-Adhering FR Cap Sheet' er "Rube«roid SA Cap FR Sheaf" self adhered. 55. Dents NC Eridlrtc: 1. Znsuiatien (Optional): — Peritce, fiber glass, poiyisocyanurete, urethane or patina /polyisocyanurate composite, offset 6 -in. from joints. Base Simian — One or mere plies Type 62 "GAIrGL?S *75 ease Sheet", or "Tri -Ply *75 Base Sheet', or Type 63 "GAFGLAS Mineral Surfaced Cap Sheet", or `Tri -Ply Mineral Surfaced Cep Sheet ", hot mopped or mechanlealiy fastened. Ply Sheet (Optional): — One or more plies Type 61, hot mopped In piece. Membrane: — One ply °Ruberald Torch Smooth' or "Ruberald Mop Smooth ". Membrane: — One ply "Rubeerid Mop Flt ". Inclines 1 In Melee (Optional): — Polyiaoeyanurate, wood fiber, per glass fiber, nhy thickness, hot mopped or mechanically fastened Base Sheets — One or more piles Type 62 "GAFGLAS *75 Seta Sheet ", sr °TrI-PIy *75 Sase Sheet ", mechanically fastened. Ply Sleet a — One or more pnea "Ruberold 20 ", hot mapped in piece. Membrane: — one ply "Ruberoid 585 H - ua FR" or ` _ _ R" heat welded in place. 57. Dena: C -15/32 Inclines 1/2 Base Sheet: — Tyro or more plies TYpe 62 "CAFCLAS *75 base Sheet" or "Tri -Pty *75 Base Sheol", mechanically fastened. Membrane: -- One ply "Rube raid SBS Heat liteId Pius FR" or "Ruberoad SBS Heat Weld 170 FR" heat wehled In piece. Page 14 of 4a SECTION 84402.13 HIGH VELOCITY HURRICANE ZONES m REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. !o' ' . Aesthetics - Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renaited in accordance with the current provisions of Section R4403. (The roof deck Is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or owner should notify the occupants of adjacent units of roofing to be performed. 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. Owner /Agent's Signature Date Revised on 7/9/20091.0 0 h/, Contractor Signature Date