ROOFING PERMITS
AREA # PULLS LOOSE TILES BROKEN/ CRACKED TILES ADHESIVE DELAMINATED FROM UNDERLAYMENT TILES DELAMINATED FROM UNDERLAYMENT PASS FAIL Field c . Aate he.() E. g®6. 441) t Perimeter IfQ f '04k1 Corners i (12 �" PiA 7ARA AND ASSOCIATES., IINC., Metro -Dade County Approved Testing Laboratory Lab. Certification # 98- 0116.01 Roofing Laboratory Testing & Research Moisture, Up -lift, Fasteners Testing Complete Building & Roofing Inspections Consulting Engineers CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH METRO -DADE COUNTY PROTOCOL PA -106 Property Address: PVC / II 7e- 2 - Permit # % 61 S Owners Name: .4kd/e z . PC #. 97 - // Z . /6 Contractors Name: / 15. X442' Approx. Square feet area: (9 f — /�d Type of Tile /��/ /� R7/0'19 • Date Tested: Testing Equipment: Digital Chatillon DFIS 500 Required Testing Force: 35 lbs. 1/ Roof Slope 5 The static uplift quality control test for the property in question, complies with Code requirement 3404.3 and Protocol PA -106. "ROOFING SKETCH" Ricar•o A. Carl s, P.E. P.E. #0043890 2524 West 3rd Ave., Hialeah, Florida 33010 • (954)433 -1484 • Fax (954)437 -2296 eter L. Z • a Lab. Director Owner's Name and Address. _.. Jacobs Disapproved _ f Date (Signed) MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Date 5 ,.3j55 , 19 No 801 Street....a 91 To:'r. Registered Architect and /or Engineer Name and address of licensed contractor .Lan3__ucQ_`'is4;__rand Tile __.SJO_ 430 N_ rl._..79:t }l.._at..__, Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done 8Q1_.N ^?^_ State work to be done and purpose of building (by floors) and for no other purpose. New Building X Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Covering '2113 Estimated Total cost of improvements $ �' 5 5 0 00 Amount of Permit $ 5.00 Zone cubage required Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building perinit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors,.on work to be performed er this permit, as are licensed by Miami Shores Village. Lari ti00Y l ilg and Tile L. 1 � 0 Remarks (Signed) 430 N. W. 7 °, th St., City STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No 1 _ f ( Date o 4/- Read, Sworn to and Subscribed before me. Notary Public, State of Florida 'Ihspector My Commission Expires PLANNING BOARD DATE Chairman Member Member ___ Member Menthe ._ . -. - Member Cou it Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re-inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. Mr. Wm. R. Bradford Miami Shores City Hall 10050 N. E. 2nd Avenue Miami Shores, Florida 33138 Dear Mr. Bradford: 4 11'11 gW‘Q qVR. fay C_O04C1v. February 17, 1977 In 1972, we purchased our home located at 801 N. E. 91st Terrace, Miami Shores and have continued to live at said premises. The roof on our home was in poor condition and has reached a state wherein it can no longer be patched according to the roofers. It must be replaced by a completely new roof. We procured estimates for replacement and made an agreement with Biscayne Roofing Co. to put on a new shingle roof. Our financial condition is such that we were compelled to borrow from a financial institution, funds necessary to pay for the replacement under the contract. On February 14th, the contractor informed us that he could not procure a permit unless the new roof was tile. The cost of a tile roof is approximately double the estimate for the shingle roof. The cost of the shingle roof is $1,840.00 and the cost of the tile roof would have been $3,500.00. In no way, are we financially able to borrow any additional money to put on a tile roof. A shingle roof would be done in a workman like manner and would be a credit to the appearance of the home and the area. The existing roof is extremely leaky, unsafe and as mentioned, cannot be patched. We proceeded in good faith and according to our financial means and respectfully ask the Board to grant a permit for the installation of the shingle roof. To do other than to permit us to proceed would be an extreme hardship to us. Respectfully yours, hine M. Fitzge • SZ' cr. h. ea., -9 gel 04, 7/ ift RI,- 2 2 #e) 801 NE. 90r<»4 Mr. Wm. R. Bradford Miami Shores City Hall 10050 N. E. 2nd Avenue Miami Shores, Florida 33138 Dear Mr. Bradford: In 1972, we purchased our home located at 801 N. E. 91st Terrace, Miami Shores and have continued to live at said premises. The roof on our home was in poor condition and has reached a state wherein it can no longer be patched according to the roofers. It must be replaced by a completely new roof. We procured estimates for replacement and made an agreement with Biscayne Roofing Co. to put on a new shingle roof. Our financial condition is such that we were compelled to borrow from a financial institution, funds necessary to pay for the replacement under the contract. On February 14th, the contractor informed us that he could not procure a permit unless the new roof was tile. The cost of a tile roof is approximatuiy double the estimate for the shingle roof. The cost of the sh:i.ng1e roof is $1,840.00 and the cost of the tile roof would have been $3,500.00. In no way, are we financially able to borrow any additional money to put on a tile roof. A shingle roof would be done in a workman like manner and would be a credit to the appearance of the home and the area. The existing roof is extremely leaky, unsafe and as mentioned, cannot be patched. We proceeded in good faith and according to our financial means and respectfully ask the Board to grant a permit for the installation of the shingle roof. To do other than to permit us to proceed would be an extreme hardship to us. February 17, 1977 Respectfully yours, 1 -ti , 7 — Thomas k J. jJae / j Jos hine M. gerald, ; Fitzgerpfd T. J. Fitzgerald 801 N. E. 91st Terrace Miami Shores, Florida 33138 Mr. Wm. R. Bradford Miami Shores City Hall 10050 N. E. 2nd Avenue Miami Shores, Florida 33138 PM ( 7F E 8 t \ 19 7 7/ PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 10 ZJob Address Ei31 t t Qli mCTax Folio /1 3z010 as C7 / 22-0 Legal Description Il.v"& T )�U l } ate.,AL6t, (' �/ d0 Owner / Lessee / Tenant �l �- c N .� q caAnaci2_, Owner's Address Contracting aC" l b Qualifier ICS. ( r-\). n�' t� SSIL - State 0‘....134... < <nicipal # Competency # Architect /Engineer Address Bonding Company Address Mortgagor Address Permit Type(circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN ALLALAhr;01 r?Ci .�i�'a/ ( 7) (L 1 6/1/f,eevi Square Ft. 02VCJ(/ WORK DESCRIPTION WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Fur hermore, I authorize the above -named contractor to do the work stated. C' ; ature oro er and /8r Condo President Si Dat a : Notary as t. • er an My Commission Fxpirec• Lana G. Ethered ** * * APPROVED: n o Presi FEES: PERMIT e OFFICIAL NOTARY SEAL LAN`:A G i:I'FIERE.DGE NOTARY PUBLIC STATE OF FI * COmAISSION N6 CC204.274 MY COMMISSION EXP. JUNE 9,1996 ent RADON Zoning Mechanical Phone " Sq 23 9 Address CcYao Phone q 22- - '41,3 f Estimated Cost(value) Master Permit # Ins.Co. /06 Xe_ 14 'I(y)o , � / itur o' Contractor or Owner- Builder Notary as to Contractor or Owner- Builder My Cofiy[ssion,.Epi ; rgs: .:..,'.::. Gb i.+.nish MY COMMA:SS,Cti'+: EXPjk it .:i; i:v+3cst 04 , 999$ ilOND6S4 iiedif ..;, Si :Y.: e':0- . [air � * * * * * * * * * ** C.C.F. NOTARY TOTAL DUE Fire Other Building Electrical Plumbing Engineering PERMIT* TAX FOLIO NO. /1 c"5o LO(1O• State of Florida County of Dade kfir R -L Z General description of Improvement: 3. Owner Information: a. Name and Address: b. Interest In property: 4. Contractor: (name and address) 5. Surety: a. Name and Address b. Amount of bond $ 6. Lender:(Name and address) STATE OF FLORIDA COUNTY OF DADE 1 HEREI>Y CERTIFY that this 19 a M cop9 cA triD origina"l in this ?ft ice on / / d l� A. D. 19 7 WITPlEI.S my band and Official Seal. NOTICE OF COMMENCEMENT THE UNDERSIGNED hereby gives notice that Improvement will be made to certainz real property, and in accordance with Chapter 713, Florida Statutes, the c-; following Information is provided In this Notice of Commencement. 0, 1. Description of property:(Iegal description of the property, and street ri address I f available) � ( 1) , q � noCo +_ ( 411(1 -f lo)ro 12 ?-y/tt add() (07/ cC) \3,t4-iininp (04 - rHtTr►- /s -. c. Name and address of fee simple titleholder (If other than owner): roe I n ( ( DAR nc w Zo k & - t - x:u4w co 0 3302_0 P 6 1 irvui e „0 . � S 2 7. Persons with the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes:(Name and address) 8. In addition to himself, Owner designates to receive a copy of the Llenor's Notice as provided In Section 7.13.13(1)(b), Florida Statutes. 9. Expiration date of notice of commencement (the expiration date Is 1 year from the date of recording unless a different date Is spa fled) Sfgnatufe I of Oar Sworn to and subscribed before me t h i s 2nd da 'PfoF11CCA43'dTn�frY56AL 11 LANA G ETHEREDGE NOTARY PUBLIC STATE OF FLORIDA Nota y P u b l i c L ana G. theredge May Comm' ss I o Iflslii NO. CC20 MY COMMISSIO ' EXP. fti.NE 97i95 7 of 0.4 A 0. 14:4"`i =AC. 1:2u. GENERAL INSTRUCTIONS • WIND RESISTANT These shingles have a special thermal sealing tab cement that firmly bonds them together after application When exposed to warm sun temperatures, they will seal to the Course below during Spring through Fall in a matter of days. In Winter. sealing time is variable, depending upon geographical for ;etion FOR APPLICATION IN POTENTIAL HIGH WINO AREAS SEE NAILING INSTRUCTION IN STEP 7 NOTE • The film strip on the back of each shingle Is to prevent sticking together of the shingles while in the bundle its removal is not required during application. • ROOF DECKS: For use on new or re- roofing work over well- seasoned. supported wood deck, tightly- constructed with maximum 6" wide lumber, having adequate nail - holding capacity and smooth surface Plywv J decking as recommended by the American Plywood Assn is acceptable Plywood decks for Class A mstalrations must be %" thickness or greater with undertayments as noted below. Shingles must not be nailed or stapled directly to insulation Re -roofing - Cut back old shingles at eaves and rakes. and install new wood edging strips as needed Make surface smooth and use beveled wood strips if necessary. Roof decks and existing surfacing material must be dry prior to application • SLOPES AND UNDERLAYMENT: Underlayment is required on new construction and required for re roofing when old roof is removed to the deck Use only 'Breathe! Type material like GAF Shingle Underlayment or equivalent Underlayments must be Installed flat, without wrinkles Standard slope - 4" rise In 12" run or more Use one layer of underlayment. appluM a5 shown In step No. 1. Low slope - 2" rise up to 4" ruse in 12" run Use two layers of underlayment. applied as shown in Step IA to meet requirements of applicable FHA M P S 1 Application of underlayment, noncorroding metal drip edges and eave flashing (for standard slope decks - 4/12 or morel Eave Flashing - In localities where teaks may be caused by water backing up- roof above ice dams that may form along eaves, install eave flashing. Use GAF Weather Watch `M ice and water barrier or equivalent, extending from the eave • edge to a point at least 12" beyond the inside wall line. Thoroughly seal all laps. COVER DECK WITH SHINGLE UNDF El( AVMENI MUST BE INCIATI rll ' W WRINK rS USE ONLY [5011011 5511 S TO III"! 0 C r D 'OI NOERLAV ME NI 5(1 I 1. UN „I CrN HE nV WGL I. ALONG HAKE PLACE. DRIP ED01 I)ECI ON TOP 01 1151)! RI.AV ME N MINIMUM Si OP! 2 Starter Course - Apply as shown. Be sure to nail securely along rakes and between the dabs of self - sealing cement along eaves. START Al EITHER RAV..E AND LW IN EITHER (1014 NONCORRODING METAL DRIP EDGE . TRIM THIS MUCH \ � • FROM END Or FIRST SHINGLE STARTER COURSE Class A Asphalt Roof Shingles APPLICATION INSTRUCTIONS' 4 IN SIDE LAP ALONG r AVES PUT IINOERLAVME.NT ON TOP 01 METAL DRIP 15:1 FOR LOWER SLOPES SEE 12 SPECIAL INSTRUCTIONS UNDERLAVMENT CONTINUE WITH FULL LENGTH TRIMMED SHINGLES NAIL AS SHOWN A !GN SHINGLES WITH OUTE4 EDGE Or NONCORRODING METAL DRIP EDGE TRIM TABS OFF ALL STARTER COURSE SHINGLES IHF.N PLACE AND NAIL AS SHOWN • • NAILS: Use 4 nails g y per shingle Use only steel 7:I enough pe o et r e ! 9 l { pt i � "e u ugh to pe rl et rn t e l rtolld, dec or ad lus 0 to 12 gauge barbed shank roofing nails, long through plywood deck. (See block No. 7.1 Oo not face nail (No nail heads. • STAPLES: Staple application In place of nails is acceptable on neW COrlttltlCtion as reroofing Must be 16 gauge minimum, zirtc- coated, have a 15/18 ". rninlmusi crown and legs long enough to penetrate Y" into wood deck or through plywood sheathing. Staples are to be driven with pneumatic stapler adjusted so that entire crown bears tightly against shingle without cutting the surface Raised staples can result in shingle distortion and may. prevent - sealing. Four staples must be used In lull shingles. The staple placement mutt be 5 %" uo from butt edge, with crown parallel to the length of the shingle and with no leg closer than 1" from end of shingle. Specific locations must be I" and 12" from each end of shingle: • EXPOSURE: Five (51 inches • THROUGH VENTILATION: All root structures must be provided with Mtough ventilation to • ''• prevent entrapment of moisture laden air behind roof sheathing. Ventiteedn,provtsions must ; 1 meet or exceed current F H A or H U D' minimum requirements. Roof deck mustbe dry at time of shingle application , +, • NONCORRODING METAL DRIP EDGES: are recommended aldrig rake andi93e edges on an "• decks. especially plywood decks. • PLASTIC CEMENT: Must conform to Federal Specifications S8C.153•type)•o ► latest revision thereof. J a mmommonommommuoimmi ALl SHEETS ARE :15 WOE EXCEPT i STARTER STRIPS * These application,nshuctrons also pertain To Sentinel shingles (CONTINUED ON OTHER SIDE) USE METAL DRIP 11)01 AS SHOWN ON '1r1P FOR MAXIMUM WIND RESISTANCE ALONG RAKES CEMENT SHINLES TO DECK AND EACH OTHER UNDERLAYMENT EAVES • LOVI% SLOPE ' `'�, _ tiro. • t' PLACE ei11Md es cLa OtSO TOGETHER BUT D O1'T.CROWD CONTINUE FIRST COURSE, WITH WHOLE SHINGLES IMPORTANT: , \ awn FIRST COUR86 WRH ',Wei PUCE 50)501ES N L \ SHINGLE PLACED 341) W, OVER' CORRECTLV NAIL. 5•B' EAVE AND RAPS EDGES 11) ,•+ ABOVE CU I OI,1 f S. PROVIDE DRIP EDGE. '_ 5.B 41401A Bull EDGE 0 ONE INCH IN FROM EACH END AND DIRF.CTI V OVER CUTOUTS iry ��•th. LAP SHE }ta,IN • TO PW.AIDEISOUBLE , OVERLAY ''"$TAFFTEFISTRIP 19144 MME la Application of underlayment, noncorroding metal drip edges and eave . flashing (for low slope decks - under 4/12 down to 2/12 - and for .• compliance with F.H.A. requirements.) When applying these shingles on decks sloping bet ir,4'dn,12 l`i'to 2 in 12, completely cover the deck with two layers of underlayltietit'a ilfibinn below. GAF Weather Watch may be used in place of the cemented undeileyment. In place of separate "eave flashing" material, apply a continou• layer :Ol plastic asphalt cement between the plies of underlayment from the eave up roof r. to a point at least 24" beyond the inside wall line. Use metal drip•edges (see step No. 1). ' USE PLASM ASPHALT USF B! wD IIAII IN!'. GNU' • CEMENT BETWEEN PLIES AS EAVF FLASHING :P /I f.' • 3 Application First Course - Start and continue course with 11'401ngies laid Hush with the starter course No manual cementing down of these tthin les is required. Shingles may be laid from left to'right or right to left. •00101 lay shingles straight up the roof since this procedure can cause an inciarreet color blend on the root. w ' CUT CHINGI F A7 SLOT MAIRNO 40417'.6 r,' F 12 1N. H A 0 SHINDIES FROM F ACM `.TRIP "\-., ' R M 441 W401 " IMP nr144 •' r '• 1 111 % t•: N •',F�1N1.. r. 0(40'.(740'11.,1 , Ml 444 01 •■ rI ASHINO TO 1,74 DONN T'FR I". E F L ASIIING 4 1 )f11II 1;1.011 J. ' flail f 1 lrl rgrlt1111N1hff. , .11l Llrl :.11 11 ever nun !Terre' r',e•: ati Shown 41111S of ShinglEschonlll t ^e ?nil 'er+' In too of cut -outs '.1' ' 'Tarrying shingles so that there will he 5' o' f'arh , ,hmylo • exposed Strike r• , Ik line about every 5 courses to check r•r:•'h.Tl alu)nrnent with eaves +"actnl, ..ppherr colt sealing dots on a lower tour' 1.0 / " Iq'ied to seal down the shingle tab's in ar 'inner Bourse NOM SRUII 1 •'•1 N '•'. ti RI ft I. MIRA!'. . .ti a I� CHIMNEY FLASHING N FKFr11(114 r � ■ THESE S'IIN:.I FS LAI ON 'HALVED MAR SFCI •ND MAT , Y. n" A 1 "HAMED "'IY 41 '111(040 CON TINA' 01111 '011011 ' 111.011( I -, ', tom.. )I ) I ).-. t�+l' - 1 , ' . ,.-1 i' 1 . ; ) 1' FLALI T OD APPLIED FD 109 9 S n 'M INI ' f 1' .H x / m • . 01 n",I nor 08.11' 'N; R . i ... ..1 (n1. +r011RE1 '711. Mf 171 1 141414 47 , L ASIAN(. 444 USE I • .r SF.PWCFAOLE FLASHING COMPOUND ARAI IF ovrn ENO Or 5118 ••• 8■6 AGAINST MASONRY THE0 ('04! 0En'N. -" erre • ,a N.'NC0f1.0 '.11 'AI I' ^.91 FLASHING 8 HIP AND RIDGE SHINGLES Use standard 1,1,' .Ind r•r'ge shingles or cut them from these shingles and apply as shown OFND'I A 11 AWAYFPOM 5N•Nr,1E 07181184. 00444 NAILS Cl 1 1 , Y, 1 171 CRF1:110N WITH CFMF PT 0 H!P p47 nIU r. } rIMDERTEX'M „ NAIL 5 51 IN • • ABOVE BUTT. I IN •OfyA EDGE 51N EXPOS1101, PRECAUTIONARY NOTES Royal Sovereign is a Fiber Glass, Self - Sealing Asphalt Shingle. Because of the natural characteristic' - , of the high - quality waterproofing material used. these shingles will be stiff In cold werlther and flexible in hot weather. The following reco r.rnended application instructions and precautions represent acceptable industry practice. GAF will not be responsible for problems that may result from failure to'.omply with these practices 1. At temperatures below 40 "F., bundles should nol be dropped on edge nor Should attempt be made to separate shingles by ' breaking" over ridge or other bundles 3 'T a r; 'formal good rooting practice and particularly important below temper ohs E's of 40 'F 2 Handle carefully ' hrngles can ea;•Iv be broken in cold weather Or their edges damaged in ho' weather 3. If hip and ridge ar" to be rlrt tr.,rn these shingles• they should be cut from the back bsn'ur'lll' Nte In cold weather they can be more easily formed to tit • the ridge 11 they 1- • I t Ir' d In 3 warm indoor area 4 When forming hill 4 ,1 ridge 01 valley Imstruction. shingles must be sufficiently warm 1. terr'. oe•'..•'r P':pecrally In cold weather. F (:AF HDlldlnn M++ • ' C nrpordlnn • '2 ?(1.35 AT VALLEY CONSTRUCTION • Construct vritews as , .hewn, use 24 gauge noncorroding nometalning metal, 36" wide. QPEN Vhf LEY TOP or /441' r • ". Yll F11 1'07:40 1 .100011S Rf'0E +I ■A• '1 I.r .l: 4(1(71 • CARRY UNDFRLAr4E NT ACROSS VAl II' fib' WIDE STRIP 01 NONCORR001'1'. N')445181010(, 24 G4U(.1 ME 1A( CROP TOP CORNE0 SHINGLES AT VALLEY PLASTIC ASPHALT Roor CFMrN' DON'T NAIL 700044174 VALLE0 CEMENT SNINn118 DTM'N WITH• PLASTIC CEMENT 7 NAILING INSTRUCTIONS NORMAL WIND AREA �•. NAl1.S CLOSED OR WOVEN VALLEY . ' N. 3E• MINE AALIZEo Ms STRIA ROLL ahCOQQPING AT • 'DEXTER!) LEAST 88 AT LEAST 12• CENTER 'Q lltj{ VENEER OP VALLEY NAB IN Of STRIP ,P. t4 NIMIIM pApy • CLOSER T 41 T O �T EvA L EY CENTER LINE HIGH WIND AREA and MANSARD or STEEP :SLOPE APP JCA` ION: For slopes above 21" per foot. or 60 °, use the same four fartbher placement. Atter fastening. apply dab of Shingle Tab Adhesive under each tib the size and thickness of 9 quarter. such that lower edge of dab is at least %" above bottom of overlying tab. Cernent location to be in center of each tab. Shingle must then be pressed firmly Into (.ement Excess application 'of cement can cause blistering. 9 WALL FLASHING '1.)NCOF BRICK. METAL 4145HIN0 • YYC CANT 5000 DECK 8" — E BREATHER• TYP UNOFRLAYMF.NT 111111. PLASHING . 5. Drive fasteners until they are flush with the surface: Do not not oVeriOve nails. 6. All exposed materials must be of Class A type., -... • 7. Through ventilation must be provided to prevent entrapnienf o - npitsture laden air behind roof sheathing. 8. Storage should be in a covered ventilated area - maximum temnpilatUre ' 110 °F. Pile in a flat fashion and maximum of 12 bundles high. Shingles must • be protected from weather when stored at job site. Do not dole near steam pipes, radiators. etc . 07 in sunlight. All rolls must be stored on ands. RE- ROOFING If old asphalt shingles are to remain In place.'nail doWit Or cut pWer'ikil loose. curled or lifted shingles, replace with new: and just before applying the new rooting. sweep the sui lace clean of all loose debris. Fasteners must 'be 01 sufficient length to penr irate the wood deck at least V." or just through' plywood. Note' Shingles can be applied' over wood shingles, when precautions have been taken to provide ae, eptable.smooth surface. For details see•yout GAF Territory Manager fellow ot''er above recommendattoftstor application. • '* 't This product It: :ui1. 'Ilan enure';'• t IMITL:D WARANTY only A copy of the LIMITED WARRANTY stating its terms and restrictions may be obtained 1r'om the distributor of this pnn.'in :I or dtmrnv from (AF Building Material. Cgrpnration Any deviation Iron. 1.11 rl 117 . Shall be the ,ri10 rO;uvrnlhllI'y o1 3puIIcator • • �R. W couue, Mr. Wm. R. Bradford Miami Shores City Hall 10050 N. E. 2nd Avenue Miami Shores, Florida 33138 Dear Mr. Bradford: February 17, 1977 In 1972, we purchased our home located at 801 N. E. 91st Terrace, Miami Shores and have continued to live at said premises. The roof on our home was in poor condition and has reached a state wherein it can no longer be patched according to the roofers. It must be replaced by a completely new roof. We procured estimates for replacement and made an agreement with Biscayne Roofing Co. to put on a new shingle roof. Our financial condition is such that we were compelled to borrow from a financial institution, funds necessary to pay for the replacement under the contract. On February 14th, the contractor informed us that he could not procure a permit unless the new roof was tile. The cost of a tile roof is approximately double the estimate for the shingle roof. The cost of the shingle roof is $1,840.00 and the cost of the tile roof would have been $3,500.00. In no way, are we financially able to borrow any additional money to put on a the roof. A shingle roof would be done in a workman like manner and would be a credit to the appearance of the home and the area. The existing roof is extremely leaky, unsafe and as mentioned, cannot be patched. We proceeded in good faith and according to our financial means and respectfully ask the Board to grant a permit for the installation of the shingle roof. To do other than to permit us to proceed would be an extreme hardship to. us. Respectfully yours, hine M. Fitzge REGULAR MEETING MIAMI SHORES VILLAGE COUNCIL March 1, 1977 The regular meeting of the Miami Shores Village Council was held at 7 :30 p. m. , March 1, 1977, at the Village Hall, with the following Councilmen present: Mayor Donald W. McIntosh W. Alfred Davis Dean R. Claussen James W. Condit Jon E. McLeod Mr. Earl K. Andersen, Village Manager, and Mr. William F. Fann, Jr. , Village Attorney, were also present. The meeting was opened with an invocation given by Dr. Floyd Folsom of the Miami Shores Baptist Church, followed by the Pledge of Allegiance. Mayor McIntosh reported on the Financial Disclosure ordinance passed by the Dade County Commission as part of the Citizens Bill of Rights, which will include advisory committees and boards. The Mayor also reported that the Quayside annexation request was presented to the Commission and forwarded to staff and the Planning & Advisory Board for a public hearing to be held in the next three or four months. The minutes of the meeting of February 15, 1977 were approved as written by motion made by Mr. Claussen, seconded by Mr. Davis and carried. Planning & Zoning Board minutes, Mr. and Mrs. Torn Fitzgerald of 801 N. E. 91st Terrace, were present to appeal the Board's denial of request for permit to replace a tile roof with asphalt shingles. Roofing material is not covered by the building or zoning codes and is approved as an architectural feature by the Planning and Zoning 3/1/77 -2- Board. After discussion, Mr. Claussen moved that the request for an asphalt shingle roof be approved. The motion was seconded by Mr. Davis and passed 3/2 with Mayor McIntosh and Councilman McLeod dissenting. The Planning Board denied a request made by Mr. David D. Lococo of 10707 N. W. 1st Avenue, for a permit to erect a 4 ft. chain link fence in the front and side yard of his home. Mr. Lococo was present to appeal this decision. The house originally faced on 107th Street but in 1968 the address on N. W. 1st Avenue was approved by the Village. The question now presents itself as to which is the front yard, on which there is a height limit of 3-1/2 ft. , and, a restriction against chain link as fencing material. Mr. Davis moved that the Council postpone any ruling on this request until Mr. Bradford is present at the meeting. The motion was seconded by Mr. Condit and passed unanimously. The request made by Mr. Dean R. Claussen for Waiver of Plat on Lots 8 -9 -10, Block 80, M.S. Sec. #3, was approved by the Planning & Zoning Board, conditioned on removal of encroachments. Mr. Davis moved that the Waiver be approved as recommended by the Planning & Zoning Board. The motion was seconded by McLeod and passed by four affirmative votes, with Mr. Claussen abstaining. Request for lighting of Dr. Ellenby's tennis court at 1009 N. E. 94th St. , was brought up for Council action, previously approved by the Planning Board. Mr. Condit moved that the lights be approved as recommended by the Planning & Zoning Board. The motion was seconded by Mr. Claussen and passed 4/1 with Mr. Davis dissenting. Resolution appointing election judges for Council Election of April 12, 1977. Following a reading of the resolution, Mr. Claussen moved that it be NEVTESI _. :1 .uc,T utzt E:_: Tb."Et. V46.2.`: _C i; . ,t`; : o €;ctu A1.. , 114.thil TO tom€ s`lo 1 DoUCL.r�, , . t: ::• o EQupa.... G P S A ris $ 5TAmor- ...D ow,. E.Qy L: ►b :. I CAL. i AI�:P S .zv ICE:. MINIMUM. _ # . 14 W,KE IN E.M.T. ALL LIGHTING' CIRCUITS .XCEPT Zrics..10 A y t N S L.A - To . . PtGt E::, C.OrNt Urr.. Z14 4% DIti&NG P'z:o,Qrrt STATE OF FLORIDA, COUNTY OF DADE. j Disapproved (Signed) MIAMI SHORES VILLAGE Date_ BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Date..._ 5722/55 7 , 19 ti Owner's Name and Address.__. e, ., _, M -, Street_...ZdCr_.. Registered Architect and /or Engineer Name and address of licensed contractor „ _��__i�..L�y:�3�.:.. 21�„_ :��,...__.� ...,_ 7.?.th .City Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done .80.1_11__E_ 91_12 State work to be done and purpose of building (by floors) and for no other purpose. New Building o. Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Covering T Estimated Total cost of improvements $ l 7 S • GO Amount of Permit $ 7.00 Zone cubage required plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor__. I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Pennanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such bcontractors,.on work to,,l¢e per[ reed 5ter this permit, as are licensed by Miami Shores Village. 3i7 .�OO.1 &17d 1i�c I��, r 1 Remarks (Signed) 430 1I, f • 79th St • r City Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. ' / Permit No. ______ /8/I __ Date. 5: a7 '� S Read, Sworn to and Subscribed before me. to me well known, Notary Public, State of Florida spector My Commission Expires PLANNING BOARD DATE Chairman Member Member ___ Member Menthe Member Cou • 11 Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re-inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. I c PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date l `Q q' Job Address g0/ /U � 1 / — TER-P-A( Tax Folio /B 3 L DDS D Z2 Legal Description 2OT )4 3) k- Z o c- ,o ld r: .. Y� PA-re. AA(rt: un / Tenant A� A'� C'` � 2- Master Permit # r c Owner's Address 2 0 1 N E 1 " e.A.LAL Contracting Co. /ASS Co � O r' 7 Qualifier 17 L c O L f State# CG e 0 otP7 5 Architect/Engineer Bonding Company Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICA WORK DESCRIPTION 1, tlu Cr,N. Square Ft. 5 Aa1 O v e rt S7_ 8 no Estimated Cost (value) cJ WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. • 0!• 110 Mr a e of owner and/or C 1r y COMMISSION N CC 660083 • ?• EXPIRES: June 30. 2001 .............. Bonded Thru Notary Public Underwriters • hal nin . Furthenn President Date 20 OWNERS constructio S Notary My Co FEES: PERMIT O W APPROVED: Zoning Mechanical Address Municipal # Competency # Address Address Historically Designated: Yes No Phone (10 -Q — 1S 1 — ° 6 ; °O sw le 57- - M IS` SS# Phone 305 -& 3- 95174' f/ Ins. Co. ROOFING PAVING FENCE SIGN lZ9 ko1/4.)e r .7, I �.,�z�.,lASs 5\ x.01 o rL S h.r? u t all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating re, I authorize the above -named contractor to do the work stated. RADON Building Date C.C.F. ' d2- 14)7/411 74--. / 1 1 72 1 1 / — OS 4 -0 c at 2,0a / ,f %s :-.- «., :rim - ' — 1 2 No : as to Contractor o Owner - a 1fS J V IL AIt . ii 4to My ommission Expires: NoyAEty PUBLIC STATE OF FLORIDA COMMISSION NO. CC714103 MY CO MISSION EXP. MAIL 1 7402 NOTARY Electrical BOND 3 D � D TOTAL DUE Plumbing Structural Engineer Contractor's Name: Job Address: got k Q 1 -ye 14 , b,,A i ROOF CATEGORY ❑ (Low Slope Application) ❑ (Nail -On Tile) L(Mortardhesive Se' t T ft ❑ (Asphalt/Fiberglass Shingles) ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other) ROOF TYPE ❑ New Roof iRe roofing ❑ Recovering ❑ Repair ❑ Maintenance Flat Roof Area (ft') PJ k Sloped Roof Area (ft') ZZCX° Total (f) Z ZOO Master Permit No. Exposure category (per ASCE 7-88): ,Vt Building Classification category (per ASCE 7 -88 table 1): 2 Ft. Ft. A v A V Deck type: 'O(OI, ATTACHMENT )! Fastener Type: 1/L4 /� J v ��� SPACING Field: Perimeter: Corner: 6 DETAIL 1 & 2 Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed) ROOF PLAN Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. MEAN HEIGHT Deck type: Woo Underlayment Insulation: 12 " ROOT !LOPE 5� f- r VAT / L TLo,r X 2-0 7— 20 .o /4"/ ►N D E T A I L 3 SLOPED SYSTEM DESCRIPTION S / ®r► - 30 1 NCA,rvRA E.Hwet7worRiravc., /1/41 Fastener type & spacing: Cap Sheet: Roof -/ Covering: Drip edge: 457 Ty ( S 1/4 "NAiis' 1Z "OCv c- 6 " o,c, "Vrcl, 0 Q,01) T2.04 S 1 Zit. MowteR Co olct.11..R,,v 20 0eSCO‘N Z-6 h 0 GO UA ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals (Pmaz1: Z° X X (Aerodynamic Multiplier): ) - (Pmax2: 0 X (Aerodynamic Multiplier): Z' ) - (Pmax3: -X X (Aerodynamic Multipliery°' 4 2*q ) - TILE CALCULATIONS M = M : , 4-G P M Ga3y_ x: 2300 4 $ A: B' M =M 1 A �slver S V Page -2 NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION TAX FOLIO NOX // 3 2 00S O 2 26 PERMIT NO. STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: / C7 / / iA.) c' * K. 2 o F �-c ld f=,1. C. ,o/) r IC ADDi 1 , o r'co r_D 70 774 2 P / 44-T ,i .5 rr ce) i , t ,7 , ; ' P4-7* /'zk', / p 3 - O /v 7 7"E 2 ice= f s rL 33/ 3 ? 2. Description of improvement: V-ex y VCC/u Frrr° (QA 112_ 3. Owner(s) name and address: Interest in property: Name and address of fee simple titleholder: 4. Contractor's name and address: 5. Surety:(Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 6. Lender's name and address: /-t---rS (�✓ AA 77- /© Z -) / ,5 4 /G S T /Lill,'" / r 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: Notary Public Print Notary's Name My Commission Expires: Signature of Owner //�� Print Owners Name K-0 -% Sworn to and subscribed before me this 7 —Oda of APc' 1 , 19 C kR . W TN BENITO SIBILA MY COMMISSION # CC 6.60083 EXPIRES: Jun 99R2 1 10 18 1999 APR 23 13 :48 3' / OF FLORIDA, COUNTY 0 ••. D QREBY CERTIFY that this is a true c Ig r111;1 A D 19 and ONicial Seal. jib I N I; FR ., q ; , it nndr'n,,nty c -' 5 my h 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different dat • 0 Prepared by: Address: �� /d ^- T M /A:.-1 FG 332C 123.01 -52 1096 M PRODUCT CONTROL NOTICE OF ACCEPTANCE Monier Lifetile LLC 135 NW 20 St. Boca Raton, Florida 33431 Your application for Product Approval of: r Lifetile LLC Villa, Capri, & Roll Tiles un er hapter of the Miami -Dade County Code governing the use of AItc, n: to Materials and Types of Construction, and completely described in the plans, specifications and CZ Ic'Jlations as submitted by: Redland Technologies, The Center for Applied Engineering, Inc., and P o''essional Service Industries has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions set forth on pages 2 -14 and thf: stindard conditions on page 15. This approval shall not be valid after the expiration date stated below. The Bui lding Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Building Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compliance Office reserves the right to rcvcke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. ACCEPTANCE NO.: 97- 1124.16 EXPIRES: 06/25/01 Revises: 95- 0322.07 95- 0322.03 95- 0316.04 METRO' ITAN DADE COUNTY, FLORIDA i/E RO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 \' /EST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375-2901 FAX (305) 375 -2908 PRODUCT CONTROL DIVISION (305) 375-2902 FAX (305) 372 -6339 aul Rodriguez Product Control Supervisor THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Miami -Dade County Building Code Compliance Office and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. 901 \)E q 1 - 1`e a.a. . Co lon - C k (o\) APPROVED: 06/25/98 1 Internet mall address: postmaster @bulldingcodeonlIne.com • u .- Charles Danger, P.E. Director Building Code Compliance Dept. Miami -Dade County Homepagefhttp://www.buildIngcodeonlIne.com MONIER LIFETILE LLC Monier Lifeitile LLC Capri Tile Trim Pieces Product Rainproof II Ice and Water Shield TRADE NAMES OF PRODUCTS MANUFACTUREL LABELED BY APPLICANT Product Dimensions Monier Lifetile I= 16'/," LLC Villa & Roll w = 13" 'A" thick L = 17" W= 12 3/.„ '''A" thick I = varies w = varies varying thickness Dimensions 30 "x75'roll 36 "x75'roll or 60" x 75' roll 36" x 75' roll Test Specifications PA 112 PA 112 PA 112 Test Specifications PA 104 PA 103 Page 2 of 15 Low profile, pressure extrud equipped with c n• double roll ribs. battened nail -or., : adhesive set apr: Low profile, inter; pressure extrude equipped with o; . double roll ribs. 7 battened nail -on, n adhesive set appi:c Accessory trim, (0: pieces for use at hi: :;, ridges and valley term 3t Manufactured for c profile. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Product Description Single ply, nail -on underlayment with 2" self - adhering top ( edge. Self - adhering underlayment Product C r . : 97- 1124.16 Des, high -c roof tile )ie and :: deck or r high roof tile :c and .: deck or :cfacturcr .: -O -Wrap, nc. rent NOA) :race Co. : NOA) Frank Zuloaga, RRC Roofing Product Cor :,river MUNLLK LIt'E'I'ILE LLC Product Wood Battens Tile Nails Tile Screws Roof Tile Mortar ("Ti 1eTiteTh ") Roof Tile Mortar ( "Quikrete® Roof Tile Mortar #1140 ") Roof Tile Mortar ( "BONSAL® Roof Tile Mortar Mix ") Roof Tile Adhesive ( "Polypro® AH 160 ") Hurricane Clip & Fasteners Dimensions Vertical Min. 1:'x 4" Horizontal Min. 1"x 4" for use with vertical battens or Min. 1"x 2" for use alone Min. 8d x 2 V," or min. 10dx 3" #8x 2 /2" long 0.335" head dia. 0. 131" shank dia. 0.175" screw thread dia. N/A N/A N/A N/A Clips Min. 'A" width Min. 0.060" thick Clip Fasteners Min. 8d x 1 ''A" Test Specifications Wood Preservers Institute LP — 2 PA 114 Appendix E Corrosion rc5. screw or smo shank nails PA 114 Appendix E Corrosion res coated. squart drive, galvani coarse thread • screws PA 123 PA 123 PA 123 See PCA Page 3 of 15 Prodt Descrip Salt pressure treated or de resistant !um vattens Prepared mort • mix designed mortar set root applications. Prepared mort: - mix designed f mortar set roof applications. Prepared morta mix designed fc mortar set roof applications. Two component polyurethane adhesive design for adhesive set roof tile applications. PA 114 Appendix E Corrosion resist; clips with con resistant nails. oaga, Roofing Product Produ : No.: 97- 1124.16 Manufacturer generic generic generic ermuda Roof 'mpany, Inc. with current PCA Qu ikrete Construction Products with Current PCA ". R. Bonsai Co. th current PCA foam Products, Inc. :;1 #94- 0401.01 Generic Test Agency Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. EVIDENCE SUBMITTED Test Identifier 7161 -03 Appendix III 7161 -03 Appendix III 94 -084 94 -060B 25- 7094 -1 25- 7094 -7 25- 7094 -4 25- 7183 -1 25- 7183 -2 Page 4 of 15 Test Name/Report Static Uplift Testing PA 102 Static Uplift Testing PA 102(A) Static Uplift Testing PA 101 (Mortar Set) Static Uplift Testing PA 101 (Adhesive Set) Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, New Construction) Static Uplift Testing PA 102 (4" Headlap, Nails, Battens) Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, Recover/Reroof) Static Uplift Testing PA 102 (2 Quik -Drive Screws, Direct Deck) Static Uplift Testing PA 102 (2 Quik -Drive Screws, Battens) ran uloaga, RRC Roofing Product Contro - cr ate :994 )94 94 ,; — Y/-1114.16 1991 1991 1994 1994 MONIER I .TE.E LLC ncv The C, : :Applied Engine The C: :or Applied Engin :. 1: • Redlar. ;:r. ;logies • Redla:. fogies Redla::. iogies The C., ::or \pplied Engine Proles. Sc. vice Indust: Test Identifier Test Name/Report Date 25- 7214 -2 25- 7214 -6 7161 -03 Wind Tunnel Testing Dec. 1991 Appendix II PA 108 (Nail -On) Redla:: :. logies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 PA 108 (Nail -On) P0631 -01 PO402 Withdrawal Resistance Sept. 1993 Testing of screw vs. smooth shank nails Project No. 307025 Test #MDC -76 224 -47099 Page 5 of 15 Product Control No.: 97- 1124.16 Static Uplift Testing PA 102 (1 Quik -Drive Screw, Direct Deck) Static Uplift Testing PA 102 (1 Quik -Drive Screw, Battens) Wind Tunnel Testing PA 108 (Mortar Set) March, 1995 March, 1995 July 1994 Wind Driven Rain Oct. 1994 PA 100 Physical Properties Sept. 1994 PA 112 oaga, Roofing Product Control Examiner MONTR LIFETILE LLC Deck Type: Wood, Non - insulated Deck Description: New Construction 19/ or greater plywood or wood plank. SYSTEM A: Counter -Batten Application Slope Range: SYSTEMS Product Conti -i 07- 1124.16 2 ":12" to 7 ":12" Note: Counter - Battens, as noted below, are required f( • 2 ":12" to less than 4 ":12" and are optional for r r - 7 ":12 ". For slopes exceeding 7 ":12 ", refer to S� Underlayment: Install underlayment system in compliance with Dade pplication Standard PA 118. Vertical Battens: Install vertical battens in compliance with Dade County / •I Standard PA 118 Horizontal Battens: Install horizontal battens in compliance with Dade ( pplicat:on Standard PA 118. Roofing Tile: Install tile in compliance with Dade County Applicatiol i PA 118. (See "Data for Attachment Calculations" included in this A Comments: 1. For re - roof applications, 15 /32" plywood is an acceptab; Page 6 of 15 Roofing Product C Inge ":12" to a niner MONIER LIFETILE LLC SYSTEMS (CONTINUED) Deck Type: Wood, Non - insulated Deck Description: New construction 19 /32" or greater plywood or wood plat SYSTEM B: Direct Deck Application Slope Range: 4 ":12" to 7 ":12" Note: System B is only acceptable in this slope range. , less than 4 " :12 ", refer to System A. For slopes in excess , refer to System C. Underlavment: Install underlayment system in compliance with Dade '.pplication Standard PA 118. Roofing Tile: Install tile in compliance with Dade County Applicatic PA 118. (See "Data for Attachment Calculations" included in this / -• Comments: 1. For re -roof applications, 15 /32" plywood is an acceptal: Page 7 of 15 Product Co 97- 1124.16 uloaga, RRC Roofing Product Cor - finer MONTER LIFETILE LLC Pro Deck Type: Deck Description: SYSTEM C: Slope Range: Underlayment: Horizontal Battens: Roofing Tile: Comments: SYSTEMS (CONTINUED) Wood, Non - insulated New construction 19 /32" or greater plywood or w Horizontal Batten Application 4 " :12" or greater Note: Horizontal battens, as noted below, are of 7 ":12" and are optional for slopes of Tess than 4 ":12 ", refer to System A. Install underlayment system in compliance wit! Standard PA 119. Install horizontal battens in compliance with Standard PA 119. Install tile in compliance with Dade County Ap: (See "Data for Attachment Calculations" included ; 1. For re -roof applications, i plywood is an Page 8 of 15 Frank Zuloaf Roofing Pro- No.: 97- 1124.16 slopes in excess "':12 ". For slopes J :y Application my Application :'2ndard PA 119. :';Straf -I Examiner MON K LIFETILE LLC Product ( '7 -1 124 Deck Type: Deck Description: SYSTEM D: Slope Range: Underlayment: Roofing Tile: Comments: Wood, Non - insulated SYSTEMS (CONTINUED) New construction 19 /32" or greater plywood or wood Mortar or Adhesive Set Application 2 ":12" to 7 ":12" Note: System D is only acceptable in this slope rat' of 7 ":12 ", refer to System C. Install underlayment system in compliance with D. • A1:2, ication Standard PA 120. (See System Limitation #5.) Install tile in compliance with Dade County Applic (See "Data for Attachment Calculations" included in ti 1. For re -roof applications, 15 /32" plywood is an accc• Page 9 of 15 ran Zuloaga, Roofing Produc res •• excess •rd ;'A 120. ) ::ltc. •. _aminer MONIER LIFETIME LLC SYSTEM LIMITATIONS I. The standard minimum roof pitch for Monier Lifetile LLC Villa, Monier Lifeti ri & Monier Lifetile LLC Roll, low profile tile shall comply with Dade County App PA 1 18, PA 119 or PA 120, depending on the method of installation. Bards 2. For nail -on applications, fasteners for mechanical attachment of tiles shall hart larger than that of the preformed holes in the tile. peter 3. System installation shall be in compliance with the system specifications outlin oduct Control Approval. The method of attachment utilized shall provide sufficient a . ( :sistancc to meet or exceed the required resistance determined in compliance with Dade ( I col PA 115 or PA 127. Tile profiles listed here in have been tested for both wind chara • 2 d static uplift performance, therefore, attachment calculations for installation in complir : d 115 or PA 127 shall be done as a 'Moment Based System'. 4. For adhesive set tile applications, a field static uplift test by a Dade Counry acc: i ,ri agency, in compliance with Dade County Protocol PA 106, shall be performed. 5. For tile applications, 30/90 hot mopped underlayment applications may be instal - _ icular to the roof pitch unless stated otherwise by the underlayment material manufactt: • - icd literature. 6 All tiles shall bear the imprint or identifiable marking of the manufacturer's name identification in the field. Page l0 of 15 Product Cont: 7 -1 124.16 7. Applications for roofing permits shall include a completed Section II of the Unif< • Permit, a copy of manufacturer's current specifications and details, a copy of this : r ntrol Approval and a copy of the Product Control Approval of any Roofing Componen proposed tile application. Reference shall be made to appropriate data for the rec 7 tins. 8. The applicant shall retain the services of a Dade County certified testing Iaborato: in quality control in compliance with the South Florida Building Code and related p: ( mples taken shall be in compliance with Dade County Protocol PA 112, Appendix 'A'. 9. Fire classification is not part of this aceptance. Frank Zuloaga, RRC Roofing Product Contr Table 1: Aerodynamic Multipliers - X (ft') Tile X (ft') X (ft') Profile Batten Application Direct Deck Application Monier Lifetile LLC Villa Tile, 0.27 0.29 Roll Tile, and Capri Tile Direct Deck Batten s Table 2: Restoring Moments due to Gravity - M (ft -Ibf) Tile Profile 3 ":12" 4 ":12" 5 ":12" 6 ":12" 7 ":12" or greater Batten s Direct Deck Batten s Direct Deck Batten s Direct Deck Batten s Direct Deck Batten s Direct Deck Monier Lifetile LLC Villa Tile, Roll Tile, and Capri Tile 5.57 6.30 5.48 6.18 5.37 6.05 5.24 5.90 5.09 N/A Table 3: Attachment Resistance Expressed as a Moment - M, (ft -Ibf) for Nail -On Systems Tile Profile Tile Application Approved Nails Approved Screws Approved Field Clip With: Approved Eave Clip With: 1 nail 2 nails 1 screw 2 screws 1 nail 2 nails 1 nail 2 nails Monier Lifetile LLC Villa, Roll, and Capri Battens 4.10 7.10 22.90 49.10 24.20 34.80 22.10 32.20 Direct Deck 11.80 21.90 25.80 47.10 24.30 35.50 19.00 31.90 MONIER LIFETILE LLC DATA FOR ATTACHMENT CALCULATIONS Product Control No.: 97- 1124.16 1 Data noted in Table 3 is for instal ation with a 3" tile headlap. 2 Approved screws are as noted in the 'Trade Names of Products Manufactured By Others' and 'Profile Drawings' sections of this Approval. Clips on eave tile are not required for this attachment configuration unless the Required Moment of Resistance exceeds the values noted above. Page 11 of 15 uloaga, RRC Roofing Product Control Examiner MONIER LIFETIME LLC Product Control No.: 97- 1124.16 Table 3 -A: Attachment Resistance Expressed as a Moment - M, (ft -Ibf) for Nail -On Systems Tile Profile Monier Lifetile LLC Villa Tile, Roll Tile, and Capri Tile DATA FOR ATTACHMENT CALCULATIONS (CONTINUED) Tile Application Direct Deck New Construction (min. 19 / 3 2" plywood) Direct Deck Recover /Reroof (min. ' plywood) Battens 50.90 New Construction 1 Tile installation with a 4" headlap using two (2) Approved 10d x 3" long polymer coated, corrosion resistant, ring shank nails installed in manufactured holes located 2 %" from the head of the tile. Clips on eave tile are not required for this attachment configuration unless the Required Moment of Resistance exceeds the values noted above. Table 4: Attachment Resistance Expressed as a Moment - M, (ft -Ibf) for Mortar or Adhesive Set Systems Tile Profile Monier Lifetile LLC Villa Tile, Roll Tile, and Capri Tile Tile Application Mortar Set Adhesive Set Attachment Resistance 20.60 86.61 Page 12 of 15 Two (2) 10d x 3" long nails 67.50 43.00 uloaga, RRC Roofing Product Control Examiner MONIER LIFETILE LLC 1 -V4 1612" WATERLOCK PROFILE DRAWINGS NAIL HOLE 11- 314''1 -1 -12" NOSE WATER COURSE MONIER LIFETILE LLC VILLA TILE MONIER LIFETILE LLC ROLL TILE Page 13 of 15 Product Contr No.: 97 1124.16 OVERLAY 2 -1/8" uloaga, RRC Roofing Product Con:rnl Examiner 0.34 MONIER LIFETTLE LLC - le-- =a.00- 0.0 r MONIER LIFETILE LLC CAPRI ******* ■ 0.13 w— PROFILE DRAWINGS (CONTINUED) Z3 Dec. APPROVED SCREW FOR SCREW DATA IN TABLE 3 Page 14 of 15 0.131 Product Ccntro! No.: 97-1124.16 1 l — U ga, Roofing Product Control E <arn;; cr ■ MONIER• LIFETILE LLC Prod: ;7() o : 97- 1124.15 Monier Lifetile LLC ACCEP1 _''I , )7- 1124.15 135 NW 20 St. APPROV June 25, 1998 Boca Raton, FL33431 EXPIRE .June 25, 2001 NOTICE OF ACCEPTANCE STANDARD CONT[11" " ?(t' 1 Renewal of this Acceptance (approval) shall be considered after a rent on Hs been filed and the original submitted documentation, including test support:.; (;;i;: c: ::Hering documents, are no older than eight (8) years. 2 Any and all approved products shall be permanently labeled with the ii: : ; ;: s name, city, state, and the following statement: "Miami -Dade County Product Con'.: I A: - : c • d' , or as specifically stated in the specific conditions of this Acceptance. 3 Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecti; ; ;i c ; ion of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one or; inai'v rcved: c) If the Acceptance holder has not complied with all the requirement;: ): t: , : ' :p;ancc, including the correct installation of the product; . d) The engineer who originally prepared, signed and sealed the require dcc,:m : :a ion initially submitted, is no longer practicing the engineering profession. 4 Any revision or change in the materials, use, and/or manufacture of the od.: :: : r( ccss shall automatically be cause for termination of this Acceptance, unless prior \ - ittnn :tr • . oN al has been requested (through the filing of a revision application with appropriate is :) ar.: s ,:nt•d by this office. 5 Any of the following shall also be grounds for removal of this Acceptant a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for other purposes. 6 The Notice of Acceptance number preceded by the words Miami -Dade C )unt_ sic a, and followed by the expiration date may be displayed in advertising literature. I f ;.11 :rtion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7 A copy of this Acceptance as well as approved drawings and other docum it applies, shall be provided to the user by the manufacturer or its distributors and sl all fh ilable for inspection at the job site at all times. The copies need not be resealed by he crhi: ccr 8 Failure to comply with any section of this Acceptance shall be cause for ::rrn i H and removal of Acceptance. 9 This Acceptance contains pages 1 through 15. END OF THIS ACCEPTANCE Page 15 of 15 i ;intt or any Roofing Product (:on : )I :xamincr Apr -29 -98 11:39A Polyfoam Products Inc- - mE- rnatAr PRODUCT CONTROL NOTICE OF ACCEPTANCE Polyfoam Products, Inc. 2400 Spring- Stttcbner Road Spring, TX. 77333 APPROVED: 04/16/9R 1 Internet malt address: postmaster @buildingcodeonline.com APR 29 '98 11:41 954 475 -1462 P.02 METROPOLITAN DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI. FLORIDA 33130.1563 (305) 375.2901 FAX (305) 3Y5 -2908 PRODUCT CONTROL DIVISION (305) 375-2902 FAX (305) 372.6339 Your application for Product Approval of: Polyfoam Products "PoIvor° AH -160" Roof Tile Adhesive under Chapter 8 of the Miami -Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans. specifications and calculations as submitted by: The Center for Applied Engineering, Inc. and Miles Laboratories Polymers Division has been recommended for acceptance by the Building Code Compliance Office to be uscd in Dade County, Florida under the specific conditions set forth on pages 2 -14 and the standard conditions on pace 15. This approval shall not be valid after the expiration dare scared below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this pruduct or material fails to perform in the approved manner, the Building Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material rails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. ACCEPTANCE NO.: 98- 0303.02 Renews: 96- 0402.02 EXPIRES: U4 /16/01 aul Rodriguez Product Control Supervisor THIS IS THE COVERSIIEF.T, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Miami-Dade County Building Code Compliance Office and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. Charles Danger, P.E. Director Building Code Compliance Dept. Miami -Dade County Homepage: http : / /www,buildingcodeonllne.com 954 475 1462 PAGE.002 Apr -29 -98 11:39A Polyfoam Products Inc. POLYFOAM PRODUCTS, INC. Applicant: Polyfoam Products, Inc. 2400 Spring - Stucbner Road Spring, Tcxas 77383 -1132 Catceorv: Roofing Component Sub- Catetzorv: Fastening/Adhcsivc Type: Roof Tile Adhesive Sub -Tyne: Two Component Polyurethane PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING COMPONENT APPROVAL. System Description 954 475 -1462 P.03 Product Control No.: 98- 0303.02 Product Control No.: 98- 0303.02 Approval Datc: April 16, 1998 Expiration Date: April 16, 2001, Polyfoam Products, Inc., produces two - component expanding polyurethane adhesive for the attachment of clay and concrete roof tile. Polypro® A14160 is specially designed for application of concrete and clay roof tile ever a variety of roof deck substrates and underlayment materials. Polypro® adhesive is applied with proprietary Foampro® RTF1000 dispensing equipment. Approval of this product is specific to the two component mix and Foampro® RTFI000 dispensing equi pcnc��t. Alternative methods of dispensing will require a revision to this approval. Polypro® adhesive shall be applied only by 'Qualified Applicators', licensed by Polyfoam Products, Inc. Certificates and identification cards arc issued to applicators upon successful completion of a application training program. Approval of this adhesive system is contingent upon application by a 'Qualified Applicator. Contact: Pat Murray P.O. Box 1132 Spring, Texas 77383-1132 Phone: (713)350 -8888 Fax: (713)28R-6450 Page 2 of 15 Frank Zuloaga, RRC Roofing Product Control Examiner APR 2S 'S8 11:41 954 475 1462 PAGE.003 Apr -29 -98 11:39A Polyfoam Products Inc. • POLYFOAM PRODUCTS, INC. Product Control No.: 98- 0303.02 duct Polypro® Alt 160 Foampro® RTFI000 APR 29 '98 11:41 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Test Product Dimensions Specifications pcscription N/A PA 101 Two component polyurethane N/A See Detail Attached Dispensing Equipment Page 3 of 15 954 475 -1462 P.04 Frank Zuloaga. RRC Roofing Product Control Examiner 954 475 1462 PAGE.004 Apr -29 -98 11:39A Polyfoam Products Inc. POLYFOAM PRODUCTS, INC. Product Underlayment Roof Tile APR 2S 'S9 11:42 TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS Test Criteria Page 4 of 15 Product Description 954 475 -1462 PA 120 All Dade County Component Approved products as detailed in Dade County Application Standard PA 120 PA 101 All Approved roof tile systems having tested in compliance with Dade County Protocol PA 101, as detailed in the systems section of this Component Approval Product Control No.: 98- 0303.02 Manufacturer. All Dade County Approved Products All Dade County Approved Products rank Zuloaga, RRC Roofing Product Control Examiner P. 05 954 475 1462 PAGE.005 Apr -29 -98 11:40A Polyfoam Products Inc. POLYFOAM PRODUCTS, 1NC. Product Control No.: 98- 0303.02 Test Agcncy TEST REPORTS Test Identifier Test Name/Report Date Center for Applied #94 -060 Miami Dade Protocol 04/08/94 Engineering PA 101 Center for Applied 257818 -IPA Miami Dade Protocol 12/16/96 Engineering PA 101 Center for Applied 25- 7438 -3 SSTD 11 -93 10/25/95 Engineering Centcr for Applied 25- 7438 -4 SSTD 11 - 10/25/95 Engineering Center for Applied 25- 7438 -7 SSTD 11-93 I 1/02/95 Engineering Center for Applied 25 -7492 SSTD 11-93 12/12/95 Engineering — Miles Laboratories NB- 589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, 9637 -92 ASTM E 108 04/30/93 Inc. Southwest Research 01- 6743 -011 ASTM E 108 11/16/94 Institute Southwest Research 01- 6739- 062b(1J ASTM E 84 01/16/95 Institute Trinity Engineering 7050.02.96 -1 PA 114 03/14/96 Page 5 of 15 954 475 -1462 P.O6 Frank Zuloaga, RRC Roofing Product Control Examiner APR 25 '98 11:42 954 475 1492 PAGE.006 Apr -29 -98 11:40A Polyfoam Products Inc. PPR 29 '98 11:42 TYPICAL PHYSICAL PROPERTIES Prorterty Density ASTM D 1622 1.6 lbs. /ft.' Water Absorption ASTM D 2127 0.08 Lhs. /Ft Moisture Vapor ASTM E 96 3.1 l'err / Inch Transmission Closed Cell — ASTM D 2856 86% Content Page 6 of 15 954 475 -1462 P.07 . POLYFOAM PRODUCTS, INC. Product Control No.: 98- 0303.02 Results Compressive ASTM I) 1621 18 PSI Parallel to rise Strength 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Dimensional ASTM D 2126 +0.07% Volume Change -40 F., 2 Stability weeks +6.0% Volume Chanec (cry 158 °F.. 100% Humidity, 2 weeks Note: The physical properties listed above arc presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. Frank Zuloaga, RRC Roofing Product Control Examiner 954 475 1462 PAG6.007 Apr -29 -98 11:40A Polyfoam Products Inc. SYS'rums Deck Type: Wood, Non - insulated, New Construction /Reroof Deck Description: 15/ or greater, plywood or wood plank. SYSTEM A: Adhesive Sct Application Slope Range: 2 ":12" to 7 ":12" Roofing Tile: Page 7 of 15 954 475 -1462 P.08 POLYFOAM PRODUCTS, INC. Product Control No.: 98-0303.02 Underiaymcnt: Shall comply with Miami -Dade Roofing Application Standard PA 120 Any roof tile assembly having a current shall be applied in compliance with the Component Application section and the corresponding Placement Details of this Notice of Acceptance. The adhesive attachment shall provide sufficient attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with Miami -Dade County Roofing Application Standards PA 115 or PA 127. The adhesive attachment data is noted in the roof tile assembly NOA. Comments: 1. All 'System Limitations' noted in the tile Roof System Assembly Product Control Approval shall apply. Frank Zuloaga, RRC Roofing Product Control Examiner APR 29 '98 11:42 954 475 1462 PAGE.008 Apr -29 -98 11:40A Polyfoam Products Inc. 954 475 -1462 P.Og . POLYFOAM PRODUCTS, INC. Product Control No.: 98- 0303.02 SYSTEMS (CONTINUED) Deck Type: Concrete, New Construction /Reroof Deck Description: New construction SYSTEM B: Adhesive Set Application Slope Range: 2 ":12" to 7" :12" Undcrlaymcnt / Install Approved underlaymcnt system of one of the following: Waterproofing: Underlayment: (30/90 Hot Mop) fully adhered in a full mopping of ASTM D 312 type IV a.sphalt applied within the EVT range. Back nailing and laps shall be in compliance with Rooting Application Standard PA 120. Roofing Tile: Comments: APR 29 '98 11:43 Any liquid applied roofing system having a current NOA for its use as a tile underlaymcnt systcm. Any roof tile assembly having a current shall be applied in compliance with the Component Application section and the corresponding Placement Details of this Notice of Acceptance. The adhesive attachment shall provide sufficient attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with Miami -Dade County Roofing Application Standards PA 115 or PA 127. The adhesive attachment data is noted in the roof tile assembly NOA. 1. All 'System Limitations' noted in the tile Roof System Assembly Product Control Approval or waterproofing component Roofing Component Product Control Approval shall apply, as applicable. Page 8of15 Frank Zuloaga, RRC Roofing Product Control Examiner 954 475 1462 PAGc.009 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Two -Piece Barrel #1 'S' Shaped q2 Double Roll #3 Flat #4 Apr -29 -98 11:41A Polyfoam Products Inc. 954 475 -1462 . POLYPOAM PRODUCTS, INC. Product Control No.: 98- 0303.02 COMPONENT APPLICATION 1. Polypro® A11160 tile adhesive shall only be applied over an underlayment installed in compliance with application instructions detailed in its NOA.. Underlayment may bc any undcrlayments or underlayment systems listed Miami -Dade County Roofing Application Standard PA 120. 2. Adhesive application shall be in accordance with the instructions provided herein. Tthe manufacturer may provide additional instructions subsequent to this approval date which may prevail. Installation must he by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. 3. Calibration of the Foampro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "A" component shall be maintained between 1.0- 1.15 (A) : 1.0 (B). The dispense timer shall be set to deliver 0.08 to 0.15 pounds per tile as dctcrmincd at calibration. No other settings shall be approved without revision of NOA. 4. Adhesive shall be dispensed in a 17 in' to 23 in' pad at time of application. The cured pad shall bc approximately 5" x 12 ". Foam placement shall bc in accordance with the'Placetnent Details' herein. Each generic tile profile requires a specific placement, as noted in Table 1, below 5. Adhere tilt directly -in freshly applied adhesive. Tile must be set within 2 to 3 minutes after foam has been dispensed. Page 9 of 15 APR 29 '98 11:43 954 475 1462 PAGE.010 Frank Zuloaga, RRC Roofing Product Control Examiner P.10 Apr -29 -98 11:41A Polyfoam Products Inc. • POLYFOAM PRODUCTS, TNC. Product Control No.: 98- 0303.02 SYSTEM LIMITATIONS 2. Polypro® Al [ 160 adhesive shall be installed only by 'Qualified Applicators' approved and licensed by Polyfoam Products, Inc. • 3. For adhesive set tilt applications, a field static uplift test by a Miami -Dade County accredited testing agency, in compliance with Miami -Dade County Roofing Application Standard PA 106, shall be required not less than 72 hours after application to confirm tile adhesion. 4. Rcfcr to application drawings published by the National Tile Manufacturers Association for penetrations and terminations, as well as the 'Placement Details' included with NOA. 5. Refer to tile Roof Tile Assembly Product Control NOA for system acceptance with this Component. 6. Refer to the Prepared Roof Tile Assembly for fire rating. 7. Polypro® AH 160 shall not be exposed permanently to sunlight. 8. Polypro® M-(160 shall be applied with Foampro RTF1000 dispensing equipment only. 9. Polyfoam ProductsTne. shall supply Building Official with a list of 'Qualified Applicators' approved and licensed by Polyfoam Products, Inc. Omo po 'op li!dd Page l o or l s 954 475 -1462 P.11 Frank Zuloaga, RRC Roofing Product Control Examiner OSd d7c 1 dc7 DO(,'= - , , Apr -29 -98 11:41A Polyfoam Products Inc. POLYFOAM PRODUCTS, INC. LI odor Won 7) 74•10 ...... 111.4d. doom. H... Aeon.. 1/1r 1. 1"' hewn tAm out.ldo o.po of wow 111.. Ti lr lw.erl t/.. 1 ) 1. 1......... 1..Ae..1.. 1. we S... 17 1. 23 .a looker. 1w ..wt..{ with lbw pow Ulo. Il....w.. 1110 /w of {M w... oar... dl.. Most 1. .wr...e ..u... of pan Woo. [w..... .e.1 w.. N pew weed •N.. Wow OM IIwk .t w... Zo...l..r.. (,...rta. MOWN PLACEMENT DETAILS Ifoopholo Page 11 of 15 Nell through pIe.Ue *wood I..I..w ►.pulp/ efr) Ortlowel ale'o far •tw.r Olga t.retic.11..le. 44110!!:: resole O.r d Placement Detail t11: Two -Piece Barrel Profile 954 475 -1462 P.12 Product Control No.: 9g- 0303.07 OOtl —1 ►.IwI•p ■.nor ou L..71t. a wd ..r of 111.. 1111...1 AI.y Frank Zuloaga, RRC Roofing Product Control Examiner APR 25 'S8 11:44 954 475 1462 PAGE.012 Apr -29 -98 11:41A Polyfoam Products Inc_ POI,YFOAM PRODUCTS, INC. APR 29 '98 11:44 N.11 ........ pl..Il. -...«d fork." reeaabwed by s...) PLACEMENT DFTArT,S (CONTINUED) u.e«l.r....4 rel baChWbee Page 12 of 15 AmAy •w..el..+...h. .• ..hL - 17 Ca 1"7 woman. Noakes 1.......y qmNA llr 111.. Placement Detail N2: 'S' Shaped Tile Profile 954 475 -1462 P.13 Product Control No.: 9030312 Delp b,. Frank Zuloaga. RRC Roofing Product Control Examiner 954 475 1462 PAGE.2 :2 Apr -29 -98 11:41A Polyfoam Products Inc. POLYFOAM PRODUCTS, INC. MsA 1►rsrlA 'Ir11� swnswl (whom rsttulrsd �f vo/srlsyw.swt APR 29 '98 11:45 44 4‘0. sw Clssr.s IYOI• Cerro* I esrs PLACEMENT DETAILS (CONTINUED) 4.s ssrrss wJv. ssrs s/r�l�r •l prsdwsllwr ! woo I.s.w - �sA.lss. Placement Dctail #3: Ooublc Roll Profile Page 13 of l 5 *_v •••■MA+sirr YAMN 17.23 s�r.rs I,.slr Iw suatast sAtl. I 111., 954 475 -1462 P.14 Product Control Nn.: 98- 0303.02 Frank Zuloaga, RRC Roofing Product Control Examiner 954 475 1462 PAGE.214 Apr -29 -98 11:42A Polyfoam Products Inc. 1' POLYFOAM PRODUCTS, INC. f..w Course APR 29 '98 11:45 b.0 /wr.. fl..u......wl (what. rwnb..lr..1 by •.r+) PLACEMENT DETAILS (CONTINUED) 1... ..r....a, � K... .Ahwl...fyrr�w.tl.� 4 -. from - oophrloo Placement Detail #4: Flat Profile Page 14 of 15 954 475 -1462 P.15 Product Control No.: 98-0303,02 X17 .m..yh./h..lw t• w►I..w 17.23 It. oo..taot with Oh. 111.. [r.. Clw.►• food. uloaga, RRC Roofing Product Control Examincr 954 475 1462 PAGE.215 Apr -29 -98 11:42A Polyfoam Products Inc. v • v POLYFOAM PRODUCTS, INC. Polyfoam Products, Inc. ACCEPTANCE NO: 98- 0303.02 2400 Spring - Stuebncr Road APPROVED : April 16. 1998 Spring, TX 77383 EXPIRES : April 16, 2001 NOTICE OF ACCEPTANCE STANDARD CONDITIONS I Renewal of this Acceptance (approval) shall bc considered after a renewal application hus bccn filed and the original submitted documentation, including test supporting data, engineering documents. are no older than sight (8) years. 2 Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3 Renewals °I will not be considered if: a) There has been a change in the South Florida Building Code affecting thc evaluation of this product and the product is not in compliance with the code changes: b) Thc product is no longer the same product (identical) as the one originally approved: c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) Thc engineer who.originally prepared, signed and sealed the required documentation initially submitted. is no longer practicing the engineering profession. 4 Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically he cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5 Any of the following shall also be grounds for removal eddies Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or uny other purposes. 6 The Notice of Acceptance number preceded by the words Miami - Dade County, Florida, and followed by thc expiration date may bc displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7 A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall bc available for inspcction at the job site at all times. Thc copies need not be resealed by the engineer. R Failure to comply with any section of this Acceptance shall be cause for termination and retnovdl of Acceptance. 9 this Acceptance contains pages I through 15. END OFT tlis ACCEPTANCE APR 29 '98 11:45 Page 15 of 15 954 475 -1462 P.16 Product Control No.: 98- 0303.02 Frank Zuloaga, RRC Roofing Product Control Examiner 954 475 1462 PAGE.016