Loading...
1160 NE 91 Terr (9)Miami Shores Village 10050 NE 2nd Avenue Phone: 305 - 795 -2204 Permit Number: BP2004 -110 Printed: 2/4/2004 Applicant: FRANK CERAOLO Owner: CERAOLO FRANK JOB ADDRESS: 1160 NE 91 TERR Contractor BUSHER GEORGE STAMPED CONCRETE INContractor's Address: 8773 SW 133 ST Local Phone: 305 - 255 -3838 Parcel # 1132050010450 Signed: Building Permit Page 1 of 1 Legal Description: WATERSEDGE PB 9 -141 ELY3OFT OF LOT 20 & ALL LOT 21 & WLY5FT LOT Fees: Description Amount FEE2004 -1050 Building Fee $110.00 FEE2004 -1051 CCF $2.40 FEE2004 -1052 Training and Education Fee $0.80 FEE2004 -1056 Technology Fee $2.75 FEE2004 -1057 Scanning Fee $6.00 FEE2004 -1061 Builders Bond $300.00 Total Fees: $421.95 et 04 Permit Status: APPROVED Permit Expiration: 7/28/2004 Construction Value: $4,000.00 Work: INSTALL BRICK PAVER DRIVEWAY (INSPECTOR) Total Fees: $421.95 (01 Total Receipts: 00 31I.CAS _ In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responisibility for all work done by either myself, my agent, servants or employes. Signed: (Contractor or Builder) BY: COVENANT OF CONSTRUCTION WITHIN RIGHT OF WAY WHEREAS, U� /'AN)L C e ,-cio �[) (owner) following described property: Legal description/folio#: 5 — (i9S Lot Z Z Tax Folio R: requests permission to install: Thiami SIior Block Subdivision sphalt, concrete, brick pavers [ ] Landscaping [ ] Other within the public road right of way of //60 / 9/ e/ 10050 N.E. SECOND AVE. MIAMI SHORES. FLORIDA 33138 - 2382 Telephone: (305) 795 - 2207 Fax: (305)_756 -8972 , hereinafter referred to as the Owner of the (address) IN CONSIDERATION of the approval of this permit by the Village, the Owner agrees as follows: pktuECvfFy A PPR0 ti • 1. To maintain and repair, when necessary, the above- mentioned item(s) installed within the dedicated right of way. If it becomes necessary for Miami Shores Village or Dade County to make repairs or maintain said items within public right of way including restoration of street by reason of the Owner's failure to do so, such expense shall be paid by the Owner or shall constitute a lien against the above described property until paid. 2. The owner does hereby agree to indemnify and hold Miami Shores Village or dade County harmless from any and all liability, which may rise by virtue of permitting the installation of these items within the public right of way. 3. The Owner does hereby agree to remove or relocate their facilities at their own expense, within 60 days notice by the Village to do so. Failure to comply with this notice will result in the Village causing the item(s) to be removed and a lien being placed on the property and/or assessed against the Owner for all costs incurred in the removal and disposal of the item(s). 4. The undersigned further agrees that these conditions shall be deemed a covenant running with die land and shall remain in full force and effect and be binding on the undersigned, their heirs and assigns, until such time as this obligation has been canceled by an affidavit filed in the Public records of Dade County, Florida by the Village Manager of Miami Shores Village (or his fully authorized representative). SIGNED, SEALED, EXECUTED AND ACKNOWLEDGE on this day of .� SIGNED. SEALED AND DELIVERED in the present MNNssa Leq Blackwell . ; My Commission ° dddPPP DD202089 i a w Expires April 10. 2007 X- I, Lot: Legal Description: X Applicant Comments: r 1' APPLICATION FOR CEITIFICATE OF RE- OCCUPANCY to re- occupy the single family residence known as : (address) � 1 b ( frlrctce I hereby certify that I understand that the zoning. of the property is for single - famly residential use and that it is unlawful for more than one family to reside therein. I also understand that any Certificate of Re= Occupancy that may be issued by Miami Shores Village, certifies only that the referenced property is being used for single - family purposes and that such Certificate does not constitute any representation, warranty or certification as to the condition of the dwelling or other structures on s , property. Print Name For purposes of conducting the inspection required by Section 902 of the Mani Shores Land Development and Zoning Code, please contact: i ' -$72 S Contact Name: Telephone: 3) - 3/ f 3 r r+7" Buyer Seller Realtor Company Name Application Fee ($50) paid: Cash Check No. Block PB & PG: PAGE 1 OF 2 , Miami Shores, Florida. , hereby apply for a certificate Dat Inspected by: Approved Denied Dates' 7 L On behalf of Miami Shores Village, Florida, the undersigned certifies that the property described in the above application has been inspected for purposes of re- occupancy pursuant to Sections 901 and 902 of the Miami Shores Land Development and Zoning Code and that such property may be re- occupied by the above applicant for single - family residential purposes. CER i lr 'CATE OF RE- OCCUPANCY By: THIS CERI IrICATE VERIFIES THAT THE REFERENCED PROPERTY HAS BEEN INSPECTED BY MIAMI SHORES VILLAGE AND HAS BEEN DETERMINED TO PRESENTLY COMPLY WITH THE SCHEDULE OF REGULATIONS OF THE MIAMI SHORES LAND AND DEVELOPMENT CODE PERTAINING SOLELY TO THE REQUIREMENT THAT EACH ONE - FAMILY DWELLING IS USED AND INTENDED TO BE USED FOR A ONE- FAMILY DWELLING PURPOSE ONLY; HOWEVER, THIS CERTIFICATE DOES NOT CONSTITUTE ANY REPRESENTATION OR WARRANTY AS TO THE CONDITION OF THE DWELLING OR OTHER STRUCTURES ON THE PREMISES DESCRIBED HEREIN, OR ANY ASPECT OF SUCH CONDITION, AND INTERESTED PERSONS ARE ADVISED AND ENCOURAGED TO MAKE THEIR OWN INSPECTION OF THE PREMISES IN ORDER TO DE.1 hRti [NE THE CONDITION, THEREOF. PAGE 2 OF 2 MIAMI SHORES VILLA FLORIDA Date of Certification: X I Ve4 11 to re-occupy the singllee family residence known as : (address) l ib V /1)e ! ( �G -2 , Miami Shores, Florida. Legal Description: Lot: Block PB & PG: I hereby certify that I understand that the zoning of the property is for single-family residential use and that it is unlawful for more than one family to reside therein. I also understand that any Certificate of Re= Occupancy that may be issued by Miami Shores Village, certifies only that the referenced property is being used for single-family purposes and that such Certificate does not constitute any representation, warranty or certification as to the condition of the dwelling or other structures on s property. X Applicant Date Print Name f **************** �******* * * * * * ** * * * * * * * * * * * * * * * * * * * * * * ** For purposes of conducting the inspection required by Section 902 of the Nfiami Shores Land Development and Zoning Code, please contact: Z S �r7 Contact Name: Telephone: 33 Ste' q-s - - 7/`( 3 Buyer Seller - Realtor Company Name Application Fee (550) paid: Cash Check No. Inspected by: Approved ( Denied Dateq f 2 -- Comments: APPLICATION FOR CERTIFICATE OF RE OCCUPANCY PAGE I OF 2 , hereby apply for a certificate CERTIFICATE OF RE- OCCUPANCY On behalf of Miami Shores Village, Florida, the undersigned certifies that the property described in the above application has been inspected for purposes of re- occupancy pursuant to Sections 901 and 902 of the Miami Shores Land Development and Zoning Code and that such property may be re- occupied by the above applicant for single- farndy residential purposes. By: THIS CER I Lt-ICATE VERIFIES THAT THE REFERENCED PROPERTY HAS BEEN INSPECTED BY MIAMI SHORES VILLAGE AND HAS BEEN DETERMINED TO PRESENTLY COMPLY WITH THE SCHEDULE OF REGULATIONS OF THE MIAMI SHORES LAND AND DEVELOPMENT CODE PERTAINING SOLELY TO THE REQUIREMENT THAT EACH ONE-FAMILY DWELLING IS USED AND INTENDED TO BE USED FOR A ONE- FAMILY DWELLING PURPOSE ONLY; HOWEVER, THIS CERTIFICATE DOES NOT CONSTITUTE ANY REPRESENTATION OR WARRANTY AS TO THE CONDITION OF THE DWELLING OR OTHER STRUCTURES ON THE PREMISES DESCRIBED HEREIN, OR ANY ASPECT OF SUCH CONDITION, AND INTERESIEL PERSONS ARE ADVISED AND ENCOURAGED TO MAKE THEIR OWN INSPECTION OF THE PREMISES IN ORDER TO DE thR MLNE THE CONDITION, THEREOF. PAGE 2 OF 2 M CA:�II SHORES VILLA , FLORIDA Date of Certification: FRANK CERAOLO (305)318 -3644 (786)439 -2739 p 0� I 1(9/.6 Passed Inspector Comments Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until nspection Number: INSP - 5568 Inspection Date: 01/10/2006 Inspector: Grande, Claudio Owner: CERAOLO, FRANK Job Address: 1160 91 Terrace NE Project: <NONE> Contractor: Monday, January 9, 2006 Miami Shores Village, FL Building Department Comments Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Cl. Block: Permit Number: RC- 1 -06 -72 l Permit Type: Residential Construction Inspection Type: Re Occupancy Work Classification: Re- Occupancy Phone Number Parcel Number 1132050010450 Lot: Page 2 of 2 (Rev. 10/02/03) • RE- OCCUPANCY 0y APPLICATION +656' Date Property Address City Miami Shores State Applicant Na Signature Sign: Print: My Com NOTARY PUBLIC: Miami Shores Village Building Departr9ryi Contact Name FJ/ 4-o Le) is ernandez # DD476455 SEP. 27, 2009 Bonded Thru Atlantic Bonding Co., Inc. oc ID Phone # Buyer Seller ✓ Realtor ✓ Company Name 1/6 « _ q/C3 Tow G M 050 N.E.2nd Avenue hores, Florida 33138 Tel: (305) 795 -2204 Fax: (305) 756 -8972 No. RCOb -1 Z 36 S- 3/F 78b — y35 -z7�9 Fl zip 33/V - 3 V o I hereby certify that I understand that the zoning of the property is for single- family residential use and that it is unlawful for more than one family to reside therein. I also understand that any Certificate of Re- Occupancy that may be issued by Miami Shores Village certifies only that the referenced property is being used for single- family purposes and that such Certificate does not constitute any representation, warranty or certification as to the condition of the dwelling or other structures on the property. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate. The foregoing instrument was acknowledged before me this q day of JAS , 20 C6 , b t-- lam. LOvho is personally known to me or who has produced as identification and who did take an oath. Buil s . Officials Approval: Re -Occ. $60.00 1 Notary $5.00 CCF $0.60 Total 6G _ CEO 'JAN 09 PAID INSTALLER MODEL RETAIL MODEL DESCRIPTION " EINIMm ®d1Elaillmm 93 83 _ 24 GA. STEEL SKIN; 18 GA. STEEL END STILES 111911 11 94 84A 24 GA. STEEL SKIN: 18 GA. PAINTi;jz 11 II DOOR HEIGHT "L " mMIffilani BRACKET PLACEMENTS EINIMm ®d1Elaillmm moraranumagannumomi 111911 11 ®131m111 ®TEEN Ilil IILI! MODELS 83, 84A, 93, 94 0 o c U cc w OU) o L TWO POINT LOCKING INTO TRACK PER SFBC 3603.2 5/8" MIN. ENGAGEMENT OPPOSITE SIDES F DOOR) (SEE LOCK OPTIONS) L" END STILES ATTACHED TO DOOR SKIN WITH PATENTED TOG -L -LOC SYSTEM (TOP, BOTTOM, & CENTER) ONE INTERMEDIATE STILE BETWEEN EACH EMBOSS ATTACHED WITH TOG -L -LOC (TOP & BOTTOM) AND URETHANE ADHESIVE (ALONG CENTER) LOCATION OF OPTIONAL VENTS &MAXIMUM VENT OPENING: 60 IN MAX. DOOR WIDTH = 9' -0" INSIDE EIIVAT10N NOTE 1; DOORS 6 HIGH CONSIST OF ( 4) SECTIONS; (2) OF 21' & (2) OF 18 ". DOORS 7'0" HIGH CONSIST OF 4 SECTIONS; 4 OF 21'. DOORS 7'6" HIGH CONSIST OF 5 SECTIONS; 5 OF 18 ". DOORS 8'0" HIGH CONSIST OF 5 SECTIONS; 2 OF 21" & (3) OF 18 NOTE 7; SUPPORTING STRUCTURAL ELEMENTS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER FOR WIND LOADS SHOWN ON THIS DRAWING. 13 GA. GALV. STEEL FLAG BRACKET. EACH FASTENED TO WOOD JAMB WITH (3) 5/16 "x1 -5/8" W000 LAG SCREW.. TRACK CONFIGURATION 2' GALV. STEEL TRACK. lc TRACK THICKNESS: .060" A A HORIZONTAL TRACK SUPPORT BY DOOR INSTALLER (TO SUIT) TYP. 2 -1/2 "x12 GA GALV. STEEL TRACK BRACKET. SEE END HINGE DETAIL SEE INTERMED. HINGE DETAIL • 0 0 O 1111 0 O O 2x6 WOOD JAMB 12 GA. GALV. STEEL TRACK BRACKET FASTENED TO WOOD JAMB WITH ONE 5/16'x1 -5/8" WOOD LAG SCREW PER BRACKET. 2' GALV. STEEL TRACK FASTENED TO TRACK BRACKETS. EACH BRACKET ATTACHED WITH ONE 1/4"x5/8" BOLT & NUT QS TWO 1/4" RIVETS. JAMB CONFIGURATION PREPARATION OF JAMBS NY OTHERS, END STILES ATTACHED TO DOOR SKIN WITH PATENTED TOG -L -LOC SYSTEM (TOP, BOTTOM, & CENTER) (INE INTERMEDIATE STILE BETWEEN EACH EMBOSS ATTACHED WITH TOG -L -LOC (TOP & BOTTOM) .\NO URETHANE ADHESIVE (ALONG CENTER) 1 LOCATION OF OPTIONAL VENTS MAXIMUM VENT OPENING: 60 IN' MAX. DOOR WIDTH = 5 0" INSIDE Fl riA11011 SUDE BOLT LOCK ENGAGES INTO VERTICAL TRACK. ONE LOCK ON EACH SIDE OF DOOR. INSIDE SI IDE BOLT IOCK OPTION - ALL DOOR MODELS ARE RAISED PANEL EMBOSS 1111 IIIII( 11 INTER. 7..T LE OUTS DE HANUL; 111 111 111 OUTSIDE KFYED IOCK LOCK BAR LOCKING 111 A r A L END STILE LOCK BAR GUIDE LOCK BAR ENGAGES IN TRACK ON EACH SIDE OF DOOR. STOP MOULDING BY DDOR INSTALLER (TO SUI 20 GA. MIN. CALV. :TEEL END STILE 20 GA. GALV. STEEL INTER. STILE INTER. STILE OUTSIDE KEYED HANDLE 18 GA. GALV. STEEL INTER. HINGE FASTENED TO CENTER STILE 1V/(4) EACH •14x5/8" SHEET METAL SCREWS. 7/16" PL'SFNUT INSTALLED ON ROLLER SHAFT FOl JNRESTRICTED DOOR OPERATION. 14 GA. GALV !.TEEL END HINGE FASTENED TC END STILES W /(4) EACH #14x5/8" /4" 3/4" ;EE SELT TAPPING SCREWS. (4) 2" STEEL ROLLER. INSIDE HANDLE OUTSIDE KEYED LOCK SNAP LATCH LOCK OPTION SNAP LATCH ENGAGES ONTO VERTICAL TRACK. ONE SNAP LATCH ON EACH SIDE OF DOOR. TWO POINT LOCKING INTO TRACK PER SFBc 3603.2 5/8 MIN. ENGAGEMENT (OPPOSITE SIDES OF DOOR) (SEE LOCK OPTIONS) 14 GA. END HINGE THE 2x6 VERTICAL WOOD JAMBS ARE TO BE GRADE 2 OR BETTER YELLOW PINE. NO LOAD IS TRANSFERRED TO THE HORIZONTAL (TOP) JAMB. ALL JAMB FASTENERS MAY BE (BUT NOT REQUIRED) COUNTERSUNK TO PROVIDE A FLUSH MOUNTING SURFACE. 2x6 WOOD JAMB CAN BE ANCHORED TO GROUT REINFORCED BLOCK WALL OR CONCRETE COLUMN. BLOCK CELLS SHALL BE FILLED WITH CONCRETE AND REINFORCED WITH CONTINUOUS #5 BAR EXTENDING INTO THE FOOTING AND INTO TIE BEAMS. ANCHORS CAN BE 1/4 "x1 -3/4" EMBED TAPCON CONCRETE ANCHORS STARTING AT NO MORE THAN 8" FROM BOTTOM AND 16" 0.C.. QB WITH 3/8 "x4" (1 -3/4" EMBED) RAWL LOK /BOLT ANCHOR STARTING AT NO MORE THAN r FROM BOTTOM AND 24' 0.C. ` Z Building Products Company END STILE 24 GA. MIN. G -60 GALV. STEEL (MIN. YIELD STRENGTH: 28 KSI, DRAWING QUALITY) WITH PRIMER AND BAKED -ON POLYESTER PAINTED TOP COAT APPUED TO BOTH SIDES OF STEEL (4) •14x5/8" SHEET METAL SCREWS (4) 1/4%3/4" SELF TAPPING SCREWS �y� � 7 //�'l (/ / f(�� DESIGN ENGINEER: %` J MARK W. WESTERFIELD FLORIDA REGISTRATION No. 48495 MECHANICAL ENGINEERING 18 GA. INTERMEDIATE HINGE CLOPAY BUILDING PRODUCTS COMPANY 312 WALNUT STREET SUITE 1600 CINCINNATI, OHIO 45202 (513) 381 — 4800 DESIGN LOADS: +42.0 PSF & -48.0 PSF. TEST LOADS: +63.0 PSF & -72.0 PSF. :CALL M14 MR 11 7 -8 -97 ADDED I -- 2" THICK OMNI m M•W omo 0n 11/18/96 PLOT 1 -42 MAXIMUM VENT OPENING SECTION A -A 12 GA. GALV. STEEL TOP ROLLER BRACKET. EACH BRACKET ATTACHED W /(4) /14x5/8" SHEET METAL SCREWS. SHIP LAP JOINTS. 14 GA. GALV. STEEL END HINGE. EACH FASTENED TO END STILES W /(4) •14x5/8" SHEET METAL SCREWS & (4) 1/4" SELF TAPPING SCREWS. 2-1/4%20 GA. GALV. STEEL U -BAR. TWO U -BARS PER SECTION, EXCEPT 3R0 SECTION WHICH HAS ONE U -BAR. U -BARS MADE FROM 80 KSI STEEL. EACH U -BAR ATTACHED W /(2) 1/4 "x3/4" SELF TAPPING SCREW PER STILE. 13 GA. GALV. STEEL BOTTOM BRACKET. ATTACHED W /(2) •14x5/8" SHEET METAL SCREWS. ALUMINUM EXTRUSION & VINYL WEATHERSTRIP. APPROVED AS COMPLYING WITH THE SOUTH FLORIDA BUILDING CODE DAT PRODUCT CONTROL DIVISION BUILDING CODE COMPLIANCE OFFICE ACCEPTANCE NO, q U 1 2.0Z amours XWfU DOOR MODELS: 83, 84A, 93. 94 IIMVP4 NYCO 101702 -24 iaw 0xw sue. 9'O'W x 8'0"H 1 Introduction ASCE7 -88 CALCULATION METHOD FOR GARAGE DOOR DESIGN LOADS FOR CLOPAY GARAGE DOORS ONLY The charts included with this cover page help calculate the design wind loads as determined using the American Society of Civil Engineers Code ASCE7 -88 for use with garage doors. The charts are divided between single car garage doors (up to 9'W x 8'H) and double car garage doors (up to 16'2 "W x 8'H). Instructions 1. Determine the garage door size as a single car door (up to 9'W x 8'H) or double car door (up to 16'2 "W x 8'H). 2. Measure the "Mean Roof Height" of the building. The mean roof height is measured i me d s e as the average height the roof, not the g h i h of h r o o h 9 g peak of the roof. The eave height may be used for a roof slope of less than f e t an 10 0 3. With the door size and mean roof height known, the appropriate g � calculation chart can be used. 4. Determine the "Minimum Building Dimension ". For example, a building (or house) with a 80' x 30' floor plan, has a minimum building dimension of 30'. 5. Measure the distance from the corner of the building to the nearest edge of the door opening. The nearer the door opening to a corner, the higher the negative design wind load. The corner wind zone of a building is defined as 10% of the minimum building dimension or 40% of the mean roof height, whichever is smaller, but not less than 3 feet or 4% of the minimum building dimension. n im g 6. The wind load can now be determined. For example a single car garage door is to be installed in a house with a mean roof height of 15' or less and a 80' x 30' floor plan. The door opening is located 2' from a corner. The design wind loads are (using the charts): +39.9 PSF and -43.5 PSF. Fill -In the Following Information Below (Type Only): Homeowner: wPndy Rcincr /Paula XduLhuppulou 1160 N.E. 91 Terrace Street Address: Fla. City: State: Z Model No.: 94 Approval No.: 97 0122.02 Miami Shores THESE MEASUREMENTS FOR USE ONLY WITH CLOPAY BRAND GARAGE DOOR PRODUCTS Evaluation criteria: ASCE7 -88 Calculations and Measurements Maximum dwelling Mean Roof Height: 15' MRH Maximum garage door width: Single car doors up to 9'0" wide x 8'0" high Measurement (in Feet) Minimum Building Dimension 30 30 35 35 35 Measurement (in Fee) Distance From Corner of Building to Edge of Opening 1.5 2.5 4.5 Measurement "C" (in Feet) End Zone Dimension ANORWMMa 3.0 3.5 3.5 4.0 4.0 4.0 4.0 2.5 5.0 Measurement "D" (in Feet) Amount of Opening in End Zone 0.5 2.5 1.5 0.5 .. 3.0 2.0 1.0 0.0 ::::........ ................ 3.5 39 9 -45.7 Resultant Minimum Positive Design Load In PSF) 39: 39 .9 ..,.,...... 39.9 ::::....:....... 39.9 ...... 045Wem . 39.9 Resultant Minimum Negative Design Load In F) -44.0 ,.,.,.,....,:,,.. .::::.:..:............ -43.1 39.9 39.9 39.9 -44.8 -44.0 -43.1 -45.3 -44.4 -43.5 -42.6 :.:::.:::::::..:....... -44.8 -44.0 .....' �`<:� ...:............ mss::: 5.0 ........................... 0.5 39.9 -43.1 These calculations are based on American Society of Civil Engineers Code ASCE 7-88 for Components and Cladding (Exposure C), 110 MPH basic wind speed, Hurricane Oceanline Importance Factor of 1.05. The calculations shown here do not apply to open or partially enclosed structures. Calculations are based on an average door size of 8Wx8'H. This calculation does not address the the supporting structure. An approximate 8% reduction in design loads is allowed if roof slope is 10 degrees or less. MEASUREMENT '9' DISTANCE FROM CORNER OF BUILDING TO EDGE OF OPENING 11. DOOR OPENING CAN BE IN EITHER LOCATION. MEASUREMENT END ZONE DIMENSION MEASIREMENT AMOUI TT OF OPENING IN ENO ZONE MEAN ROOF HEIGHT MEASUREMENT "A' MINIMUM BUILDING DIMENSION (Type All Numbers) Measurement "A ": Measurement "B ": Measurement "C ": Measurement "D ": Positive Design Load: Negative Design Load: 30' 24" 24" 24" 39.9 -43.5 These calculations are intended to cover the requirements of Section 4.0 (Conditions of Use) in the Metro-Dade Notice of Acceptance. PECHART.XLS