1140 NE 91 Terr (9)MIAMI SHORES VILLAGE
BUILDING INSPECTION DEPARTMENT
APPLICATION FOR BUILDING PERMIT
Application is hereby made for the approyal of the detailed statement of the plans and specifications herewith submitted for the build-
ing or other structure herein described This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village. Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
Date_ / 7 -- - i it , 19 4 ' . 7
Owner's Name and Address/fig £ - e t•JA, L Er,— No. I/ 1 4c> Street "i' C- 91 9. 1-2 a- - _
a.. A-n_o_ s,A
Registered Architect and/or Engineer. _.A._ CT 6-k N c) 4— S ''' - I g3lC_T: V _
Name and address of licensed contractor_ J/N. 5.-
Location and legal description of lot to be built on:
Lot_ Block Subdivision
Street and Number where work is to be done /
State work to be done and purAose of building (by floors). 4 1 %-" --.-■• : XX.,2--&-aa., 4 L ( i '"". --",.
... _,-, e ..... , 4 4: ,,4 Vr ..,+ fa - ..- c_k _
and for no other purpose.
New Building Remodeling Addition Repairs No. of Stories_
To be constructed of Kind of foundation.. Roof Covering._
" trc)
Estimated Total cost of improvements $ / Amount of Permit $
Zone cubage required _Plan Cubage
Distance to next nearest building_ Size of Building Lot
Maximum live load to be borne by each floor__
I hereby submit all the plans and specifications foi said building. All notices with reference to the building and its construction may
be sent to_
The undersigned applicant for this building permit doc hereby certify that he understands and accepts his obligations as an employer
of labor under the Florida Workmen s Compensation Act, being Sec:ion 5966, Compiled General Laws of Florida, Pennanent Supplement,
and has complied with the provisions thereof, and will require similar compliance from all contractors or sub-contractors employed by him
in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice
or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this
permit, as are licensed by Miami Shores Village.
Remarks (Signed)
STATE OF FLORIDA,
COUNTY OF DADE. ss.
Before me,
peared
Chairman
Member _____
Member .
Council Approved
undersigned authority, a notary public, duly authorized to administer oaths and take a..1:aowledgments, personally ap-
to me well known,
and who, being by me first duly sworn, upon oath deposes and says that he is the_
of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts
therein by him stated are true.
1
Permit No._ Date_ I 1
Disapproved ___ _ te
( Signed )
Building Ins ctor
PLANNING BOARD
Date
NOTE: A charge of $1.00 will be made for making corrections
the Planning Board.
A re-inspection fee of $1.00 will be charged
materials and/or workmanship.
Read, Sworn to and Subscribed before me.
Notary Public, State of Florida
My Commission Expires
DATE
Member
Member
Member
Disapproved
Date
or changes to this application after approval has been obtained from
when such re-inspection is made necessary by improper notice for inspection or faulty
MANUFACTURERS — DISTRIBUTORS
of
ALUMINUM AWNINGS
CARPET WAREHOUSE and SALES
CUSTOM MADE DRAPERIES
Pm. Bradford
Building Department
Tliani Shores Village
"Tiami Shores, Florida.
Dear ". Bradford:
741 N.W. 54th STREET
MIAMI, FLORIDA 33127
Phone 754 -5561
December 11, 1967
In accordance with our telephone conversation of this
date, I enclose herewith our check payable to the Village of
Miami Shores, Florida in the mount of si2.50 fora Building
Permit covering installation of aluminum fold —down awnings on
the home of :ors E. Gonsler, 1140 N. T. 91 Terrace, rJiat i Shores,
Village, cost of 0194.00.
('J 3
and
Other
Home
Improvement Products
llso enclosed is a plot plan with specifications attached,
together with the size and style of awning we are installing.
Thank you very much for your courtesy and cooperation.
pith my very best wishes to you and yours for happy holiday
season, I as
HGH:rh
277,9. (3)
rely ..`r s,
. Georg Harvey
General ?:Manager
Opening No.
1 .
2.
3.
Owner:
1,�s 0E
Se2�E (Zoom
A /
■
R E S I D E N C B
Contractor: RICO, INC.
Size Style Proj.
91 X 71") Catalina 60"
91 X 71 ") " 60"
91 X 71 ") to look is one. 60"
7rrs E. Gonaler
1140 N. I3. 91 Terrace
:Siami Shores, Florida.
Const.
P luminum
It
N N
1
t1 LT:
ti
ANCHOR
SEE
SCHEDULE
ANGLE- 35"
X 2.5" X .090'
INTERMEDIATE STORM LOCK
ANCHOR SEE SCHEDULE
1/13"
TR"P 3/ 4" ALUMINUM
PROJECTION A
56
71
HEADER HINGE
AWNING CLOSED
1
� /4' , . - 06dEXTRUSIONS
" i I -4 8 S. M. SCREW EA. SLAT
*10 S.M. SCREW
VALANCE
- SUPPORT ARM
BUTTON
CAMEL BACK
AWNING OPEN
TO LOCK AWNING IN STORM POSITION, REMOVE
CAMEL BACK PIN OR BOLT, RELOCATE ARMS,
FOLD AWNING DOWN AND REPLACE CAMEL
BACK PIN OR BOLT THRU VALANCE.
USE ONE FOR SPANS
6e OR GREATER.
56"
71"
WING DEI j
ADJUSTMENT HOLES
HEADER ANCHORS SHALL BE LOCATED AS SHOWN, EXCEPT AWNINGS
WITH PROJECTIONS GREATER THAN 58" AND WIDTHS GREATER
THAN 70" SHALL HAVE 2 ANCHORS AT EACH END.
II%MAX. (x
ROOF SLATS
lT I!8 S.M.SCREW EA SLAT STAGGERED, ALL PURLINS.
ROLL - ROOF SLATS 2 - #4 SMS. EA. TUBE
.0_40 - GUSSET PLATE 4-'"4 SMS.
TYPICAL PURLIN
- -2 ANGLES (SEE PURLIN DETAIL )
/ STRAP HINGE I" X .040"
I/4" BUTTON
4 SMS.
WIDTH
MAX. 91"
PLAN OF AWNING
SECTION I X - X I
I "0.0.TUBE .044' WALL
f 7/8 "TUBE .049" WALL
CAMEL BACK .080" FOLDED PL.
I /4 "DIA. PIN OR BOLT
TWO ANCHORS EA. CAMEL BACK
CAMEL BACK DETAIL
5/8" SQ. BUTT JOINT TUBE .040" WALL
USE "INTERMEDIATE STORM LOCK" 6 EACH
- END AND AT MIDSPAN FOR WIDTHS
GREATER THAN 60 ".
040 GUSSET PLATE 4 °4 SMS.
INSIDE SLAT ( EVERY 3 RD SLAT )
I/4" HOLE FOR
CLOSED POSITION
7/16" BOLT
I/4" 20 BOLTS
s /4"
9/16'
1Y2"
2- • 10S.M.SCREWS
L- 1 /4 "X I" X 115"X V2"
PURLIN
(SHOWING CONNECTION
AT EA. END OF NOSE PURLIN)
t
3 16
SLAT DETAIL
VALENCE - 6"
SEE SCHEDULE
FOR THICKNESS
ROOF SLATS
PURLIN
VALANCE
SEE SCHEDULE
FOR THICKNESS
SECTION NI- Y'
PURLIN 8 VALENCE THICKNESS SCHEDULE
PROJ. MAXIMUM VALENCE
WIDTH THICKNESS
MAXIMUM PURLIN SPMICpIG
TO NOSE TD HEADER TYPICAL
56" 78" .040"
38' 91" .040'
I6"
16"
14'
71"
71'
7r
72"
.040"
85'
.063'
91'
. 063'
le"
16'
18"
..,. I I ,NV_ TO .... I
14"
17"
D!"
I2"
ALUMINUM ALLOY OF AWNING COMPONENTS
ROOF SLATS 5005 -H34 BOLTS 2024 -T4
VALANCES 3003 -HI4
ARMS 3003-1118
PURLINS 5005 - 1118
ALL AWNING SIZES SHOWN ARE MAX. LESSER SIZES MAY
BE USED
THE JALCO SUNMASTER CATALINA AWNINGS WERE DE-
SIGNED AND TESTED IN ACCORDANCE WITH THE METRO-
POLITAN DADE COUNTY BUILDING AND ZONING DEPART
MENT POLICY FOR PLANT PRODUCED PREFABRICATED
RIGID AWNINGS, CANOPIES AND CANOPY SHUTTERS, GATED
OCT. 10, 1960. BASED ON SO. FLA. BLDG. CODE.
AWNING ARMS MAY BE MOUNTED OVERHEAD USING SAME
FITTINGS AND DIMENSIONS
THE FOLLOWING LABEL SHALL BE ATTACHED TO ALL
AWNINGS: -
JALCO INC. CERTIFIES THAT THE ALLOY AND HEAT
TREATMENT OF ALL METAL IN THIS PRODUCT CON-
FORMS TO THE SPECIFICATIONS CONTAINED IN THE
PLANS SUBMITTED FOR PERMIT COVERING THIS IN-
STALLATION. THIS AWNING MUST BE CLOSED AND
SECURED TO THE WALL DURING A HURRICANE WARNING
OR ALERT.
ANCHOR SCHEDULE
CONCRETE HOLLOW WALL WOOD
1/4" X 1-1/4" DIAMOND
HAMMER DRIVE NAL.
CR I/4 " SUPER -
GRIR JORDAN 1033 X V4
LAG.
we X 20 LONG 4
WING TOGGLE SCREW
N0.14 -I%2" LG.
W000 SCREW
JALCO INC.
745 N. W. 54th STREET
MIAMI, FLORIDA
CARR SMITH & ASSOCIATES
62T S.W. 27 AVE. , MIAMI. FLORIDA • C O N S U L T I N G
E N G I N E E R S
..n
8-641 ..... AK. 1 .oNN E.0.) c,....G.K.T.
CONT.ACTO..HALL T.IIIPI A11 OMOs1ON.
AT SITE .2TO11. /NOC[NIN. ,.ITN WOIIN.
1 64139
1 OF 1
SUNMASTER CATALINA 9!'