Loading...
1125 NE 91 Terr (7)10.30' NC \ 35.50' ONE STORY; CBS RESIDENCE# 1125 LOT 17 5' Conc.Walk 24.50' 5.5' Parkway FN D.I. P.3 /4° (NO ID) 750.00' k) FND.I.P.3i4° oIJ (NO ID) — A 23.00' 0 0 CL CO r � O N 0 x 1Ot).00'lR 4M) 4' CLF nc. Walk NE 91 TERRACE 50.00' Total R/W (By PLAT) N iLt i"aooh 18.15' 6 b 0.5' Gutter ° 23' Asphalt il-r 1 (25 tie r/ r', d i 5 ,Die6-5, 7 3 . /j6 . - w j • • 4 CP •• N • • : • O • .• • • • • aS d f U n r� ,e. .• J • •• • • • • •• • • • • • • • FND.I.p!3 /4 °; • • • .. • (NO • • • • 2 ,15' • .. • • • •Cc- . . . .. • • • • • • • ••. •• PL cia 8 tri FND.I.P.3/4° OD te WIND LOAD SCHEDULE OPENING LABEL GLAZED OPENING HORIZ. (INCHES) DIM. VERT. (INCHES) NO. OF GLAZED PANELS SMALLEST GLAZED HORIZ. (INCHES) PANEL VERT. (INCHES) EFFECTIVE WIND AREA (SQ. FT.) BUILDING ZONE (Note 4) DESIGN POSITIVE (PSF) LOAD NEGATIVE (PSF) 1 37 38 2 30 16 3.3 Interior 46.5 -50.4 2 37 38 2 30 16 3.3 End 46.5 -62.2 3 74 38 2 34 32 7.6 Interior 46.5 -50.4 4 74 38 2 34 32 7.6 End 46.5 -62.2 5 19 25 2 12 10 0.8 Interior 46.5 -50.4 6 19 26 2 12 10 0.8 End 46.5 -62.2 7 37 63 2 30 28 5.8 Interior 46.5 -50.4 8 37 63 2 30 28 5.8 End 46.5 -62.2 9 37 26 2 30 10 2.1 Interior 46.5 -50.4 10 37 26 2 30 10 2.1 End 46.5 -62.2 11 37 50 2 30 22 4.6 Interior 46.5 -50.4 12 37 50 2 30 22 4.6 End 46.5 -62.2 NOTES: 1. Wind Toads are determined in accordance with the 2004 Florida Building Code and ASCE 7 -02. 2. Wind load calculations are based upon a mean roof height as provided by the Contractor and noted herein. Contractor /Building Official shall verify the mean roof height in the field. 3. Calculation is valid for Enclosed Structures only. All glazed openings shall be impact resistant or have impact protective devices. 4. End zones for this installation are those areas within 3.0 feet of the exterior corners of the building. End zones are based on the building dimensions provided by the Contractor. Contractor /Building Official shall verify the layout plan in the field. 5. This document shall be used for determination of wind loads only. Component installations shall be in accordance with the appropriate product evaluation documents. Wind loads are applicable for component installations at any elevation below the roof. 6. Wind loads are applicable for use on window and glazing systems. For Toads on other systems, contact our office. 7. This document shall be valid only when there appears an original signature, date and embossed seal from V. J. Knezevich, P.E. 8. Use of this document is subject to the Terms and Conditions of Use, Version 1.0, available on the web at http: / /ASCE7 -02.TheTTGroup.com, and any other applicable agreements between the Client, named above, and Thornton - Tomasetti Group, Inc. / �. 13 Jun -2006 ° V. J. Knersvic , • . FL License #10983 Thornton Tomasatti Group, Inc. FL COA #7519 Roof Siope = 4.000 inches rise per 12 -inch run PROCESSED BY: Lin Ardente Roof Siope = 18.43 degrees PAGE: 1 of 2 Smallest Side of Building = 18.00 feet Internal Pressure Factor, GCpi = 0.18 (fully enclosed building) Topographic Factor, Kzt = 1.00 (non -hilly area) Directionality Factor, Kd = 0.85 (Product evaluation documents shall not incorporate allowable stress increases. End Zone = 3.0 feet Verify with product evaluation documents.) • • •.. • • • ••. •• .. • • • •• •• • Thornton D Tomasetti • .. • • •• ... •• .. .•• • •••. 330 N. Andrews Avenue, Suite 450 :: Ft. Lauderdale, Florida 33301 :: Phone: 954.522.3690 :: Fax: 954.5:26§1:: www.ThePTGroup.F6m' •' • • ••• ••• ASCE 7-02 DESIGN WIND LOADS FOR COMPONENTS & CLADDING FOR VERTICAL SUvF4gE$.• •• • • • • Basic Wind Speed, V = 146.0 m.p.h (3 sec peak gust) CLIENT: Eduardo ltp6 • • • • • • • Exposure Category = C Sunshine Home Improvements Importance Factor, I = 1.00 (non - assembly / non - essential facility) DATE: 06/07/2006, 22:20:45 Roof Eave Height = 9.00 feet STRUCTURE: James Pagliaroli Roof Peak Height = 13.00 feet 1125 NE 91 Terr. Miami, Fl 33138 Mean Roof Height = 11.00 feet ORDERED BY: EDUARDO WIND LOAD SCHEDULE (continued) OPENING LABEL GLAZED OPENING HORIZ. (INCHES) DIM. VERT. (INCHES) NO. OF GLAZED PANELS SMALLEST GLAZED HORIZ. (INCHES) PANEL VERT. (INCHES) EFFECTIVE WIND AREA (SQ. FT.) BUILDING ZONE (Note 4) DESIGN POSITIVE (PSF) LOAD NEGATIVE (PSF) 13 53 38 2 32 32 7.1 Interior 46.5 -50.4 14 53 38 2 32 32 7.1 End 46.5 -62.2 15 37 76 2 30 35 7.3 Interior 46.5 -50.4 16 37 76 2 30 35 7.3 End 46.5 -62.2 17 74 50 2 34 44 10.4 Interior 46.4 -50.3 18 74 50 2 34 44 10.4 End 46.4 -62.0 19 36 80 2 28 72 14.0 Interior 45.5 -49.4 • • ••• • • • ••• •• •• • • • •• •• • • Thornton = Tomasett f ..• ; . Page 1 for: 1. Input design data. 2. Notes applicable to the Wind Load Schedule. Note: This document is not complete without all pages. • • •• • • -- •• • • • • • .• _ ••• • • • • . • • . • • • • • • 330 N. Andrews Avenue, Suite 450 :: Ft. Lauderdale, Florida 33301 :: Phone: 954.522.3690 :: Fax: 954.5 ; wv� , .Th iTG roup.cem• • • ASCE 7 -02 DESIGN WIND LOADS FOR COMPONENTS & CLADDING FOR VERTICAL SURFI Eq • • •...•• • • • • • CLIENT: Eduardo Hep@ • • • • •.. Sunshine Home Improvements DATE: 06/07/2006, 22:20:45 STRUCTURE: James Pagliaroli 1125 NE 91 Terr. Miami, Fl 33138 ORDERED BY: EDUARDO PROCESSED BY: Lin Ardente PAGE: 2 of 2 • • • • • • •• WIND LOAD SCHEDULE OPENING LABEL GLAZED OPENING HORIZ. (INCHES) DIM. VERT. (INCHES) NO. OF GLAZED PANELS SMALLEST GLAZED HORIZ. (INCHES) PANEL VERT. (INCHES) EFFECTIVE WIND AREA (SQ. FT.) BUILDING ZONE (Note 4) DESIGN POSITIVE (PSF) LOAD NEGATIVE (PSF) 20 72 96 2 31 85 18.3 End 44.7 -58.6 21 28 96 1 24 92 15.3 End 45.2 -59.6 NOTES: 1. Wind loads are determined in accordance with the 2004 Florida Building Code and ASCE 7 -02. 2. Wind load calculations are based upon a mean roof height as provided by the Contractor and noted herein. Contractor /Building Official shall verify the mean roof height in the field. 3. Calculation is valid for Enclosed Structures only. All glazed openings shall be impact resistant or have impact protective devices. 4. End zones for this installation are those areas within 3.0 feet of the exterior corners of the building. End zones are based on the building dimensions provided by the Contractor. Contractor /Building Official shall verify the layout plan in the field. 5. This document shall be used for determination of wind loads only. Component installations shall be in accordance with the appropriate product evaluation documents. Wind loads are applicable for component installations at any elevation below the roof. 6. Wind loads are applicable for use on window and glazing systems. For loads on other systems, contact our office. 7. This document shall be valid only when there appears an original signature, date and embossed seal from V. J. Knezevich, P.E. 8. Use of this document is subject to the Terms and Conditions of Use, Version 1.0, available on the web at http: / /ASCE7- 02.TheTTGroup.com, and any other applicable agreements between the Client, named above, and Thomton - Tomasetti Group, Inc. ,, • / S __— 13 - 2006 V. J. Knezevich, . FL License #10983 Thomton- Tomasetti Group, Inc. FL COA #7519 • • • • • • • • • • • • • • • Th orn t on T omasett i � ' `� • • .• • _ � . • • • • • • • . -• • •. • • • • • • • • . • • • . . • • • • • 330 N. Andrews Avenue, Suite 450 :: Ft. Lauderdale, Florida 33301 :: Phone: 954.522.3690 :: Fax: 954.522.3691 www.TheTTGroup.com • ASCE 7 -02 DESIGN WIND LOADS FOR COMPONENTS & CLADDING FOR VERTIC L V�4� • •• • • .. • • • ••• •• • Basic Wind Speed, V = 146.0 m.p.h (3 sec peak gust) CLIENT: Eduardo Hepp Exposure Category = C Sunshine Home Improvements Importance Factor, I = 1.00 (non - assembly / non - essential facility) DATE: 0611112006, 17:21:40 Roof Eave Height = 9.00 feet STRUCTURE: James Pagliaroli Roof Peak Height = 13.00 feet M 1125 iami, 91 Terr. M, FI 33138 Mean Roof Height = 11.00 feet ORDERED BY: eduardo Roof Slope = 4.000 inches rise per 12 -inch run PROCESSED BY: Lin Ardente Roof Slope = 18.43 degrees PAGE: 1 of 1 Smallest Side of Building = 18.00 feet Internal Pressure Factor, GCpi = 0.18 (fully enclosed building) Topographic Factor, Kzt = 1.00 (non -hilly area) Directionality Factor, Kd = 0.85 (Product evaluation documents shall not incorporate allowable stress increases. End Zone = 3.0 feet Verify with product evaluation documents.)