Loading...
1077 NE 91 Terr (10)1 FORM 600A -97 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Project Name: Address: City, State: Owner: Climate Zone: I. New construction or existing New 2. Single family or multi - family Single family 3. Number of units, if multi - family 1 4. Number of Bedrooms 3 5. Is this a worst case? No 6. Conditioned floor area (ft') 1225 ft' 7. Glass area & type a. Clear - single pane 0.0 ft _ b. Clear - double pane 0.0 ft' _ c. Tint/other SC /SHGC - single pane 167.0 f1 d. Tint/other SC /SHGC - double pane 0.0 ft 8. Floor types a. Slab -On -Grade Edge Insulation R =0.0, 154.0(p) ft b. N/A c. N/A 9. Wall types a. Concrete, Int Insul, Exterior R =4.2, 983.0 ft' _ b. N/A c. N/A d. N/A e. N/A 10. Ceiling types a. Single Assembly R =19.0, 1225.0 ft' b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Con. AH: Interior Sup. R =6.0, 123.0 ft _ b. N/A I hereby certify that the pl ns and spec by this calculation are in compliance Energy Code. PREPARED DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: Florida Department of Community Affairs Residential Whole Building Performance Method A TUMANI RESIDENCE 1077 NE 91 TERR MIAMI SHORES, FL MR & MRS NELSON TUMANI South ca th the ns covered lorida 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Strip b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A Glass /Floor Area: 0.14 Total as -built points: 18390.00 Total base points: 20593.00 Builder: Re& (Set Permitting Office: Permit Number: Jurisdiction Number: c. Conservation credits (HR -Heat recovery, Solar DHP- Dedicated heat pump) 15. HVAC credits (CF- Ceiling fan, CV -Cross ventilation, HF -Whole house fan, PT- Programmable Thermostat, MZ- C- Multizone cooling, MZ- H- Multizone heating) BUILDING OFFICIAL: I PASS Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. DATE: 5 D EnergyGauge® (Version: FLRCPA -203) c° ortstro c - t oil MIAMI SHORES 4'& o7 232600 Cap: 30.0 kBtu/hr _ SEER: 11.00 Cap: 50.0 gallons EF: 0.86 Cap: 34.0 kBtu/hr _ COP: 1.00 MR & MRS NELSON TUMANI 1077 NE 91 TERR MIAMI SHORES, FL Summary Energy Code Results Residential Whole Building Performance Method A Project Title: TUMANI RESIDENCE Class 3 Rating Registration No. 0 Climate: South 3/8/00 PASS e- Ratio: 0.88 EnergyGauge ®(Version: FLRCPA -203) Energy Use Base As -Built Cooling: Heating: Hot Water: Total: 12613 points 870 points 7110 points 20593 points Cooling: Heating: Hot Water: Total: 9323 points 1795 points 7107 points 18225 points MR & MRS NELSON TUMANI 1077 NE 91 TERR MIAMI SHORES, FL Summary Energy Code Results Residential Whole Building Performance Method A Project Title: TUMANI RESIDENCE Class 3 Rating Registration No. 0 Climate: South 3/8/00 PASS e- Ratio: 0.88 EnergyGauge ®(Version: FLRCPA -203) Building Loads Base As -Built Summer: Winter: Hot Water: Total: 35431 points 798. points 6257 points 42486 points Summer: Winter: Hot Water: Total: 31123 points 1790 points 6257 points 39170 points MR & MRS NELSON TUMANI 1077 NE 91 TERR MIAMI SHORES, FL Summary Energy Code Results Residential Whole Building Performance Method A Project Title: TUMANI RESIDENCE Class 3 Rating Registration No. 0 Climate: South 3/8/00 PASS e- Ratio: 0.88 EnergyGauge ®(Version: FLRCPA -203) FORM 600A -97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: 1077 NE 91 TERR, MIAMI SHORES, FL, PERMIT #: EnergyGauge® DCA Form 600A -97 EnergyGauge® /FlaRes'97 /98 FLRCPA -203 BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Floor Area Overhang Type /SC Ornt Len Hgt Area X SPM X SOF = Points .18 1225.0 53.20 11731.2 Single, Tint N 2.0 Single, Tint N 2.0 Single, Tint N 2.0 Single, Tint N 2.0 Single, Tint S 2.3 Single, Tint S 2.0 Single, Tint E 2.0 Single, Tint W 2.0 As -Built Total: 4.5 2.5 7.0 3.5 6.0 4.0 4.5 4.5 13.0 10.0 40.0 10.0 26.0 16.0 26.0 26.0 167.0 27.68 0.86 27.68 0.75 27.68 0.92 27.68 0.81 52.00 0.75 52.00 0.67 61.31 0.78 54.85 0.78 308.5 208.7 1023.6 224.9 1012.1 559.9 1238.3 1117.5 5693.5 WALL TYPES Area X BSPM = Points Type R -Value Area X SPM = Points Adajcent Exterior Base Total: 0.0 0.0 0.0 983.0 2.70 2654.1 983.0 2654.1 Concrete, Int Insul, Exterior As -Built Total: 4.2 983.0 2.28 983.0 2241.2 2241.2 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent Exterior Base Total: 0.0 0.00 0.0 20.0 6.40 128.0 20.0 128.0 Exterior Wood As -Built Total: 20.0 9.40 20.0 188.0 188.0 CEILING TYPES Area X BSPM = Points Type R -Value Area X SPM = Points Under Attic Base Total: 1225.0 0.80 980:0 1225.0 980.0 Single Assembly As -Built Total: 19.0 1225.0 2.50 1225.0 3062.5 3062.5 FLOOR TYPES Area X BSPM = Points Type R -Value Area X SPM = Points Slab Raised . Base Total: 154.0(p) -20.0 - 3080.0 0.0 0.00 0.0 - 3080.0 Slab -On -Grade Edge Insulation As -Built Total: 0.0 154.0(p) -20.00 - 3080.0 - 3080.0 INFILTRATION Area X BSPM = Points Area X SPM = Points 1225.0 18.79 23017.8 1225.0 18.79 23017.8 FORM 600A -97 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: 1077 NE 91 TERR, MIAMI SHORES, FL, PERMIT #: EnergyGauge® DCA Form 600A -97 EnergyGauge® /FlaRes'97 /98 FLRCPA -203 FORM 600A -97 ADDRESS: 1077 NE 91 TERR, MIAMI SHORES, FL, PERMIT #: EnergyGauge DCA Form 600A -97 EnergyGauge® /FlaRes'97 /98 FLRCPA -203 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details BASE AS -BUILT Summer Base Points: 35431.0 Summer As -Built Points: 31123.0 Total Summer X System Points Multiplier = Cooling Points Total X Cap X Duct X System X Credit = Component Ratio Multiplier Multiplier Multiplier Cooling Points 35431.0 0.3560 12613.4 31123.0 1.000 0.966 0.310 1.000 31123.0 1.00 0.966 0.310 1.000 9322.7 9322.7 FORM 600A -97 ADDRESS: 1077 NE 91 TERR, MIAMI SHORES, FL, PERMIT #: EnergyGauge DCA Form 600A -97 EnergyGauge® /FlaRes'97 /98 FLRCPA -203 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Floor Area Overhang Type /SC Ornt Len Hgt Area X WPM X WOF = Points .18 1225.0 2.02 446.4 Single, Tint N 2.0 Single, Tint N 2.0 Single, Tint N 2.0 Single, Tint N 2.0 Single, Tint S 2.3 Single, Tint S 2.0 Single, Tint E 2.0 Single, Tint W 2.0 As -Built Total: 4.5 2.5 7.0 3.5 6.0 4.0 4.5 4.5 13.0 10.0 40.0 10.0 26.0 16.0 26.0 26.0 ' 167.0 4.98 4.98 4.98 4.98 3.80 3.80 3.99 4.60 0.98 0.97 0.99 0.98 1.07 1.13 1.04 1.00 63.6 48.3 197.2 48.7 1.06.3 68.9 108.1 120.1 761.2 WALL TYPES Area X BWPM = Points Type R -Value Area X WPM = Points Adajcent 0.0 0.0 0.0 Exterior 983.0 0.60 589.8 Base Total: 983.0 589.8 Concrete, Int Insul, Exterior As -Built Total: 4.2 983.0 983.0 1.02 1002.7 1002.7 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Exterior 20.0 1.80 36.0 Base Total: 20.0 36.0 Exterior Wood As -Built Total: 20.0 20.0 2.80 56.0 56.0 CEILING TYPES Area X BWPM = Points Type R -Value Area X WPM = Points Under Attic 1225.0 0.10 122.5 Base Total: 1225.0 122.5 Single Assembly As -Built Total: Type 19.0 R -Value 1225.0 1225.0 Area X 0.30 WPM = 367.5 367.5 Points FLOOR TYPES Area X BWPM = Points Slab 154.0(p) -2.1 -323.4 Raised 0.0 0.00 0.0 Base Total: -323.4 Slab -On -Grade Edge Insulation As -Built Total: 0.0 154.0(p) -2.10 -323.4 -323.4 INFILTRATION Area X BWPM = Points Area X WPM = Points 1225.0 -0.06 -73.5 1225.0 -0.06 -73.5 FORM 600A -97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: 1077 NE 91 TERR, MIAMI SHORES, FL, PERMIT #: EnergyGauge® DCA Form 600A -97 EnergyGauge® /FlaRes'97 /98 FLRCPA -203 FORM 600A -97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: 1077 NE 91 TERR, MIAMI SHORES, FL, PERMIT #: EnergyGaugerM DCA Form 600A -97 EnergyGauge ® /FlaRes'97 /98 FLRCPA -203 BASE AS -BUILT Winter Base Points: 797.8 Winter As -Built Points: 1790.5 Total Winter X Points System = Multiplier Heating Points Total X Component Cap X Duct X System X Credit = Ratio Multiplier Multiplier Multiplier Heating Points 797.8 1.0900 869.6 1790.5 1790.5 1.000 1.003 1.000 1.000 1.00 1.003 1.000 1.000 1795.0 1795.0 FORM 600A -97 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: 1077 NE 91 TERR, MIAMI SHORES, FL, PERMIT #: EnergyGaugerM DCA Form 600A -97 EnergyGauge ® /FlaRes'97 /98 FLRCPA -203 FORM 600A -97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: 1077 NE 91 TERR, MIAMI SHORES, FL, PERMIT #: 1 PASS EnergyGauge DCA Form 600A -97 EnergyGauge ® /FlaRes'97 /98 FLRCPA -203 BASE AS -BUILT WATER HEATING Number of X Bedrooms Multiplier = CODE COMPLIANCE STATUS Tank EF Volume Number of X Tank X Multiplier X Credit = Total Bedrooms Ratio Multiplier 3 BASE 7110.0 50.0 0.86 As -Built Total: 3 1.00 2424.09 1.00 7272.3 7272.3 AS -BUILT Cooling Points + Heating Points + Hot Water Points = Total Points Cooling Points + Heating + Hot Water Points Points = Total Points 12613.4 869.6 7110.0 20593.0 9322.7 1795.0 7272.3 18390.0 FORM 600A -97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: 1077 NE 91 TERR, MIAMI SHORES, FL, PERMIT #: 1 PASS EnergyGauge DCA Form 600A -97 EnergyGauge ® /FlaRes'97 /98 FLRCPA -203 BASE AS -BUILT WATER HEATING Number of X Bedrooms Multiplier = Total Tank EF Volume Number of X Tank X Multiplier X Credit = Total Bedrooms Ratio Multiplier 3 2370.00 7110.0 50.0 0.86 As -Built Total: 3 1.00 2424.09 1.00 7272.3 7272.3 FORM 600A -97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: 1077 NE 91 TERR, MIAMI SHORES, FL, PERMIT #: 1 PASS EnergyGauge DCA Form 600A -97 EnergyGauge ® /FlaRes'97 /98 FLRCPA -203 COMPONENTS - SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors Exterior & Adjacent Walls Floors 606.1.ABC.1.1 Maximum:.3 cfm /sq.ft. window area; .5 cfm /sq.ft. door area. ✓ A-1 /mil 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows /doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top /bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. 4./ 606.1.ABC.1.2.2 Penetrations /openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimete penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. . 610.1 i Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Separate readily accessible manual or automatic thermostat for each system. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. /)74 , / `� Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6 -12. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built -in heat trap required. ✓ A-1 /mil Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non - commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal ef of 78 %. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. / Air Distribution Systems 610.1 i All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R -6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R -19. Common walls -Frame R -11 or CBS R -3 both sides. Common ceiling & floors R -11. - FORM 600A -97 Code Compliance Checklist Residential Whole Building Performance Method A - Details I ADDRESS: 1077 NE 91 TERR, MIAMI SHORES, FL, PERMIT #: 6A -21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST 6A -22 OTHER PRESCRIPTIVE MEASURES (m EnergyGauge DCA Form 600A -97 EnergyGauge ® /FlaRes'97 /98 FLRCPA -203 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 85.4 The higher the score, the more efficient the home. MR & MRS NELSON TUMANI, 1077 NE 91 TERR, MIAMI SHORES, FL, 1. New construction or existing New 2. Single family or multi - family Single family 3. Number of units, if multi - family 1 _ 4. Number of Bedrooms 3 5. Is this a worst case? No 6. Conditioned floor area (ft 1225 ft' 7. Glass area & type a. Clear - single pane 0.0 ft _ b. Clear - double pane 0.0 ft _ c. Tint/other SC /SHGC - single pane 167.0 ft _ d. Tint/other SC /SHGC - double pane 0.0 ft 8. Floor types a. Slab -On -Grade Edge Insulation R =0.0, 154.0(p) ft b. N/A c. N/A 9. Wall types a. Concrete, Int Insul, Exterior R=4.2, 983.0 ft _ b. N/A c. N/A d. N/A e. N/A 10. Ceiling types a. Single Assembly R =19.0, 1225.0 ft _ b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Con. AH: Interior Sup. R =6.0, 123.0 ft _ b. N/A Builder Signature: Date: 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Strip b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR -Heat recovery, Solar DHP- Dedicated heat pump) 15. HVAC credits (CF- Ceiling fan, CV -Cross ventilation, HF -Whole house fan, PT- Programmable Thermostat, RB -Attic radiant barrier, MZ -C- Multizone cooling, MZ- H= Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Address of New Home: City/FL Zip: Cap: 30.0 kBtu/hr _ SEER: 11.00 Cap: 34.0 kBtu/hf _ COP: 1.00,, Cap: 50.0 gallons EF: 0.86 *NOTE: The home's estimated energy performance score is only available through the FLA /RES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPA /DOE EnergyStar' your home may qualms for energy efficiency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 407/638 -1492 or see the Energy Gauge web site at www.fsec. ucf. edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs al 850/487 -1824. EnergyGauge® (Version: FLRCPA -203) 1 Location for weather data: Miami - Defaults: Latitude(25) Temp Range(L) Humidity data: Interior RH (50 %) Outdoor wet bulb (75F) Humidity difference(56qr.) Winter design temperature Winter setpoint Winter temperature difference 47 F 70 F 23 F Summer design temperature Summer setpoint Summer temperature difference 90 F 70 F 20 F Total heating Toad calculation 16334 Btuh Total cooling load calculation 22975 Btuh Submitted heating capacity Submitted as °AD of calculated 0 Btuh 0.0 % Submitted cooling capacity Submitted as % of calculated 0 Btuh 0.0 % Load component Load Window total 167 sqft 5354 Btuh Wall total 983 sqft 4030 Btuh Door total 20 sqft 254 Btuh Ceiling total 1225 sqft 2940 Btuh Floor total 154 ft 0 Btuh Infiltration 72 cfm 1575 Btuh Internal gain 3000 Btuh Subtotal(sensible) 17153 Btuh Duct gain 1715 Btuh Total sensible gain 18868 Btuh Latent gain(infiltration) 2727 Btuh Latent gain(internal) 1380 Btuh Total latent gain 4107 Btuh TOTAL HEAT GAIN 22975 Btuh Load component Load Window total 167 sqft 4442 Btuh Wall total 983 sqft 4620 Btuh Door total 20 sqft 212 Btuh Ceiling total 1225 sqft 1348 Btuh Floor total 154 ft 2864 Btuh Infiltration 82 cfm 2070 Btuh Subtotal 15556 Btuh Duct loss 778 Btuh TOTAL HEAT LOSS 16334 Btuh Residential System Sizing Calculation Summary Project Title: TUMANI RESIDENCE MR & MRS NELSON TUMANI 1077 NE 91 TERR MIAMI SHORES, FL Winter Heating Load for 1225 sgft Summer Cooling Load for 1225 sgft WINTER CALCULATIONS SUMMER CALCULATIONS EnergyGauge® FLRCPA -203 Latent infil.(12%) - Wlndows(23%) Oain(13 %) Duds( ? %) .. Intil.(7 %) Doors(1 %) Int. Ducts(5 %) Latent internal(6 %) Wat (26 %) Walls(18 %) Class 3 Rating Registration No. 0 Climate: South 3/8/00 Ceilings(13 %) The sizing method used was EnergyGauge® System Sizing. PREPARED BY: DATE: Sec. 6 -3 Air Conditioning Regulations. Miami Shores Village (a) All individual air conditioning units installed in walls or windows shall be securely anchored to the walls by approved methods. Units installed over public property, paths of egress or more than ten (10) feet above grade shall be secured to the structure by bolts or screws to resist horizontal wind loads. Such units cantilevering more than eight (8) inches on the exterior of a building shall be supported by steel angle bradoets secured by bolting. Bolts to masonry shall be set in lead shields or similarly rot - resistant fastenings. (b) The following special requirements shall apply to the control and regulation of noise nuisance from air conditioning machinery. (1) All equipment, existing or hereafter installed, regardless of location, shall be maintained in good working order. Equipment so located that normal operating noises create a nuisance to adjacent owners or occupants shall be provided with soundproofing, or sound- absorbing baffels, or enclosures, as approved to insure maintenance of a reasonable noise leveL (2) All equip :rent on outer walls, on roofs, or in the other exposed locations, which are unduly noisy, and which causes valid complaints from adjoining property owners or occupants may be required to be relocated, redesigned and/or enclosed in noise- retarding materials when, in the opinion of the building official, such enclosure is necessary or would be effective. Special consideration shddl be given to the planning of all future installations to minimize the noise nuisance to adjoining property owners or occupants and the building official shA1i have authority to reject or require the redesign of any system which, in his opinion, would cause such a noise nuisance. (3) (c) Violation of this section haft be punished as is now or may hereafter be provided by law (Ord. No. 299, Sec. 1 -3, 2- 21 -61). I have read the above ordinance and will comply with the regulations thereof er /signature • y Contractor Signature ve read the above ordinance and will comply with the regulations thereof BUILDING ELECTRICAL PLUMBING ROOFING Architect Contractor or Builder ! / MIAMI SHORES VILLAGE. FLORIDA 0 ❑ DATE ❑ PERMIT N? 6753 Contractor's License No. 0 Owner of Building Legal Lot Description ! Bl. Address of r - Building / Signed Work to be performed under this Permit Subdi- f+ % vision t Value of Project $ <Z' / 7s ?Y 195 V I Amount of / II Permit $ This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings cr in the sta)ements or specifications and that he assumes responsibility for work done by his agents, servants or employees. 3 INSPECTOR In consideration of the issuance to me of this permit I agree to perform the work covered here(nder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In ac- cepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. CONTRAC,TOR OR BU 7 BY AUTHORITY BUILDING ELECTRICAL PLUMBING ROOFING MIAMI SHORES VILLAGE, FLORIDA DATE o PERMIT N9 6044 Owner of Building Architect Contractor .....; or Builder 4 ^1 4,4 (...._. llt l.,we V . G 0 U Legal Lot 0 Description II BI / — ?U — hod 19 Contractor's 13 License No Work to be performed under this Permi 1 -J9• Subdi- vision Address of C Value of 9 0 .... ..... 4) I Amount of v Building / 0 1 1 11 5 r f / - J. Project $ I Permit $ �' This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the applica- tion herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes respon- sibility for work done by his agents, servants or employees. Signed. INSPECTOR In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with ordinanc regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In ao cepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. 4,1 C.4,12A42 CONTRACTOR OR BUILDER BY AUTHORITY ABBOT MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other stru ture herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Villag -, Fonda, and all provisions of the Law of the State of FIoi da, 311 ord=nances of Miami Shores Village 'nd all rules and regulations of the Building Division of Miam Shores Village sh 11 be co _.plied with whether h r in specifie ' not. A cop of apt roved plans and specifications must be kept at bu.ld -ng during progress of the work. Dat. -_ _ Jan. 2 0,- _ _ _ _ 19.55 Owners Name and Address ___ . Will iam__M.___ Young__ ___ ____ No. _ _3.077 Street__ _ ._91 Terrace Registered Architect and /c- Engineer_______ _ ______ ___ _ Name and address of licensed contractor TRULY__NOLE i +_. ___- __.___600_._�1_.__W_.. -_ 7 - Avenue, Miami, _ Fla . Location and legal description of lot to be built on: Lot . Block Subdivision_ Street and Number where work is to be done 1077 N . E_.__ 91. Terrace. Miami __Shores,_ Fla. State work to be done and purpose of building (by floors)____ _ _ __ _ ___ _ _ __ __ ____ _ _ ___ _ __ .__ _ . __ - _ ___ _ _ _ _ -____Fumigation___ — Using Vikane an-__approximate_._20 -. ±__. hours_ exposure period. Nylon. tent.._._ _. _ and for no other purpose. n EXTER1 A TION No. of Stories __ _ New Building______ __ __ _ _. Remodeling. i Repairs To be constructed of _ ._ . _ __ Kind of foundation._ _. _ __ _ _.Frame ___ _._ _ __ __.. _ _ Roof Covering_ ._. Flat_ _Gravel_ ___- Estimated Total cost of improvements $ _ -19000- ___ ___Amount of Permit $ _5..00 -- Zone cubage required____ _____ _.__ _ .___.__. — __.Plan Cubage 15 /- 000 Distance to next nearest building 25___Ft___._________ of Building Lot_ Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to - - - - - - - - - - - - - - - - - - T h e undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employ:r of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar : ompliance from all contractors or sub- contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the wor, r. h public notice or notices as are required by the Act. The undersigned agrees to employ only such subco rs, on work o be -rf. ed under this permit, as are licensed by Miami Shores Village. Remarks — — (Signed) -- STATE OF FLORIDA, COUNTY OF DADE. j ss Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, pen a rally ap- peared _ and who, being by me first duly sworn, upon oath deposes and says that he is the - of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No. _ L 0 Disapproved - - - - - - - - - - - - - ( S i g n e d ) ..... ( e., - -- - Building Inspector Date_.._ /-- -- _ Date PLANNING BOARD __ ._ ___ _. _ _ DATE Chairman Member __ Member _ Member Member - - Mem Icr - - - -- -- - Council Approved ._ Read, Sworn to and Subscribed before me. Notary Public, State of Florida My Commission Expires __ _ _ __ to me well known, _ Date Disapproved . _ Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after appr .1 has been obtained from the Planning Board A re- inspectiol Fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship.