ROOFINGLegal Description Historically Designated: Yes No PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 9 -29 -98 JobAddress 1069 N.E. 91 TerraceTaxFolio Owner/Lessee /Tenant Juliet .Newfite4a Master Permit # Owner'sAddress 1069 N.E. 91 Terrace Miami Shores Phone 759 -2521 ContractingCo. Quality Roofing Contractor, INc. Address 13800 N.W. 1st Avenue Qualifier Carlos Arocho SS# Phone 751-0182 State # RC'. 0 0 5 S h 7 7 Municipal # Competency # 17889 Ins. Co. Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION Tear off old flat roofs to wood deck, tin cap base sheet felt as per code, install eave drip and galvanized flashing metals where required, mop on with type III asphalt one layer of Flintlastic FRP. Square Ft. 1 5 s q. Flat roof Estimated Cost (value) $ 4,000 _ 00 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. Sign FEES: PERMIT My Commission Expires: er and/or Condo president Date Notary as to 0 er and/or Condo President io - 'y - -f, ,. = MY COMMISSION # C 680474 EXPIRES: October 10, 2001 ` . pr y •' Bonded Thru Notary Public Undenvdters RADON Building 4/fajg/194' Signature of Contractor or Owner - Builder MARYLOU HOl NANDZ MY COMMISSION N CC 680474 EXPIRES: October 10, 2001 Bonded Thru Notary Publk Undenvdters Notary as to Contrafertor or Owner- Builder My Commission Expir C.C.F. p2 ' v NOTARY Electrical BOND 549a -� TOTAL DUE /b Date . /a - /Y Date Yei APPROVED: Zoning Mechanical Plumbing Engineering NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real propeny. and in accordance with Chapter 713. Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: 1069 N . E . 91 Terrace Miami Shores, Florida 2. Description of improvement: Reroof to a new Flat roof . 3. Owner(s) name and address: Interest in property: Owner Name and address of fee simple titleholder: N/A Sw-vwn 1 r1kg_ N _ 91 Pr- Pearrarp Miami Shot Florida 33138 4. Contractors name and address: Quality Roofing Contractor, Inc . 5. Surety:(Payment bond required by owner from contractor, if anyITATE OF FLORIDA;, COUNTY OF DADE 142:2E3Y CE 7 „'y that Ibis !s o Pruc jnp orhi fi!. d 'n ';';2%. office on Name and address: N/A Amount of bond $ no 6. Lenders name and address: N/A Ada Ifi/t , Signature Print 0 n-rs Name - 3 - 1) ► .k, •e.+' Srw t v c .,- Sworn to and subscribed before me this 14 day of O , 19 g . Notary Public Print Notary's Name My Commission Expires: 13800 N.W. 1st Avenue Miami, Florida 33168 I ne of 93R516411 1998 OCT 21 09:30 A• C. 19 WITN. mv 4 n -1 and Gff ir! }_.. N CAE P; .I Cl-c y 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: N/A 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: N/A 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is s•ecified) 4t. Prepared by: Carlos Arocho Quality Roofing Contractor, Address: 13800 N.W. 1st AvenuE -- bt. Florida 331 68 DEZ ,., ..: MY COMMISSION # CC 680474 h EXPIRES: October 10, 200 „ „Re ;; Bonded Thru Notary Public Undenwrtftera 111711_S9 .o . Contractor's Name: t , u417' f ipI nq („nT of Job Address: 12 Slope Application) ❑ (Asphalt/Fiberglass Shingles) l 0 Ft. Ft. 123.01.78 9/96 Appendix "E" . UNIFORM ROOFING PERMIT APPLICATI ROOF CATEGORY ❑ (Nail -On Tile) ❑ ( Metal Roofs \Wood Shingles & Shakes) - ROOF TYPE Re ❑ New Roof Re-roofing ❑ Recovering ❑ Repair ❑ Maintenance Flat Roof Area (ft') /,S S' , Sloped Roof Area (ft') 0 Total (ft') JS.s , Master Permit No. Exposure category (per ASCE 7 -88): C Building Classification category (per ASCE 7 -88 table 1): _,2* ROOF HEIGHT AND SYSTEM DETAILS , (Draw details as needed) r „ • �, a s/ F: t e leY i (frp BH ‘4' e 5kif Deck type: WOO l )(6, ATTACHMENT // Fastener Type: I/1 SPACING DETAIL 1 & 2 ; /s N /0 Field: /a 0 ,c-- Perimeter: 9 . C . Corner: (o O .0 Page -1 r r r r r r ❑ (Mortar- Adhesive Set Tile) ❑ (Other) ROOF PLAN Ridge Ventilation? MEAN IIEICHT Deck type: Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. /Ul erlayment: Insulation: 1 Fastener type & sparing: 12" ROO/ SLO D E T A I L 3 SLOPED SYSTEM DESCRIPTION Cap Sheet: Roof overing: TILE CALCULATIONS (Pmax1: x X (Aerod . • is Multiplier): ) - M: = M PCA: (Pmax2: x X (Ae odynamic Multiplier): • ) - M = M PCA: (Pmax3: x (Aerodynamio Multiplier): ) - M = M PCA: Page -2 Drip edge: ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals t•+c TRO -QAOE PRODUCT CONTROL NOTICE OF ACCEPTANCE GS Rooting Products Company, Inc. 5525 MacAuthur Boulevard, Suite 900 Irving, Texas 75038 Acceptance No.: 97- 0520.01 Revises No. 95- 0502.04 Expires: 06/19/00 Approved: 06/19/97 • ....e:net mail address: postmaster @buitdingcodeonline.com BUILDING CODE COMMITTEE METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO.DADE FLAGLER BUILDING I 40 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130. 563 (305) 3752901 FAX (305) 375.2908 PRODUCT CONTROL DIVISION (305) 375.2902 FAX (305) 372.6339 Your application for Product Approval of: GS Roofing Products Modified Bitumen Roof Systems Over Wood Decks under Chapter 8 of the Metropolitan Dade Counry Code governing the use of Alternate Materials and Types ai Construction, and completely described in the plans, specifications and calculations as submined by: Factory Mutual Research Corporation and Underwriters Laboratories. lnc. has been recommended for acceptance by the Building Code Compliance Deparment to be used in Dade County. Florida under the specific conditions set forth on pages 2 through 31 and the standard conditions set forth on page 33. The approval shall not be valid after the expiration dace stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time for a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Building Code Compliance Office may revoke, modify or suspend the use of such product or material immediately. The applicant shall re- evaluate this product or material should any amendments to the South Florida Building Code be enacted affecting this product or material. The Building Code Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by th man ac Raul Rodr Product Control Supervisor THIS IS THE COVERSHEET. SEE ADDITIONAL PACES FOR SPECIFIC .AND GENERAL CONDITIONS This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. C tar es anger. P.E. Director Building Code Compliance Dept. Metropolitan Dade County �' '� Homepage: nttp : / /•www.buildingcooeonline.corn Applicant: CS Roofing Products Company, Inc. (MB) 5525 MacArthur Blvd. Suite 900 Irving, TX 7503S Cate_orv: fvlembrane Roofing System Sub- Cateeorv: Built -up Roofing Tvoe: Modified Bitumen Sub -Type: SBS /APP s ROOFING SYSTEM APPROVAL Contact: Pat Neuhaus Commercial District Manager 2900 Bird Si Charleston Heights, SC 29405 (803) 744 -7451 Product Control No.: 97. 0520.01 Product Control No.: 97-0520.01 Approval Date: June 19. 1997 Expiration Date: June 19. 2000 System Description GS Roofing Products Company, Inc. manufactures and markets nationally a complete line of residential and commercial BUR and modified bitumen products. GS Roofing Products Company, Inc. markets these products through local distribution in the South Florida jurisdiction. GS Roofing products and systems are the result of years of manufacturing experience and product development and have been proven by years of experience in the construction field. GS offers a variety of approved insulated and non - insulated roofing systems. For detailed system constructions, refer to the following publications: "Commercial Roof System Specification Manual". GS products and systems have been tested in compliance with all provisions of the South Florida Building Code as well as Underwriters Laboratories, Inc., and Factory Mutual Research Corporation for fire and wind uplift resistance. GS provides technical service and warranty information through regional offices. For the South Florida Metro -Dade area call 1- 800. 777 -3563. ran uloaga -Plans Examine ••uct Control Div. .Insulation Tvpes Materiel Design Pressure Wood -45.0 psf Material Wood Fibrous glass Perlite Fiberboard Rockwool Polyisocyanurate Polyisocyanurate Composite Board Maximum Design Pressures Maximum Fire Classification Noce: Fire classifications and maximum design pressures do not reference all assemblies over deck types. Review system listings for design pressures and•the Underwriters Laboratories Roofing Materials Directory or other approved testing agency listing directory for Fire Classifications. • 1 Class__. ification Class A 3 Fran uloaga -Plans Exams Product Control No.: ^7.0520.01 cc Control Div. Wood Deck System Limitations: A red rosin sheet shat) be installed on all wood plank decks to eliminate asphalt seepage and bonding of base sheet to wood plank deck. Red rosin sheet may also be• installed on plywood decks as an option. 2 Pre - assembled 'Cap Nail' shall not be used for base she attachment. 3 When All Weather Empire base sheet is installed as the base sheet, a ply she of ASTNI 0 4601 type I I (type G2) must be applied in approved mopping asphalt applied within the EVT range and at a rate of 20 -40 lbsfsq prior to installation of membrane. 29 uloaga -Plans Examen . ' r Control Div. Product Control No.: 97 0530.01 GENERAL LIMITATIONS . All asphalt shall comply with ASTM D 312. type 111 or IV requirem and approved by applicant. Fire ratings are determined by a combination of slope, deck type and assembly. Refer w the current Underwriters Laboratories Rooting Materials Directory or other fire testing data listed in the testing file. Fire ratings shall be in strict compliance with Sections 3401.5 and 3401.6 ()Idle South Florida Burld;n; Code. Maximum slope range varies for each system. Consult the current Underwriters Laboratories Roofing Materials Directory and manufacturer's specifications for compliance with design criteria for each project. An overlay and/or recovery board is required on all applications over closed cell foam insulations w;;c,: the base sheet is fully mopped in hot asphalt. 5 All work shall be performed by a contractor licensed to do roofing work in Metro•Dade Count:. Contractor shall be familiar with the details and specifications published by the manufacturer a:tc t::, requirements of the South Florida Building Code. 6 The submission of system specifications and details shall accompany the Section 11 Building Code Permit. This is available in the publications listed in the 'System Description' of this Product Control Approval. The submission of these documents, as well as the proper application and installation of all materials shall be the sole responsibility of the contractor. 7 Perimeter and corner areas shall comply with the elevated design pressures of these roof areas, as calculated in compliance with Chapter 23 of the South Florida Building Code. Anchor or bast sheet fastening panerns and/or insulation attachment densities shall be increased in compliance with the provisions set forth in Metro -Dade County Roofing Application Standard PA 1 17 to meet these cicv.neo design pressures. All attachment and sizing of perimeter nailers, metal profile and/or flashing termination designs shall conform to Metro -Dade County Roofing Application Standard PA 1 1 1 and the wind load requirements of Chapter 23 of the South Florida Building Code. 9 Flashings shall be installed according to the manufacturer's standard details and may be applied in cola application adhesive, approved asphalt or may be applied in conjunction with an approved torch applied modified bitumen membrane. Specific details, approved by the manufacturer, shall be submined with the Section II Permit Application. All details shall comply with the provisions of the South Florida Building Code. 10 Fastener spacing for anchor or base sheet attachment is based on a Minimum Characteristic Reststallc c Force (F') as determined through field testing in compliance with Metro -Dade County Protocol P. 105 or PA I05(A). If F', as tested, is less than that listed in the System Limitations, a professional en;rnrcr may 'submit revised fastener spacings utilizing F', taken from a Metro -Dade County Protocol PA 105 or PA I05(A) test report, and the provisions set forth in Metro -Dade County Roofing Application Stano :o PA 117. !I Fastener density for insulation anachment is based on a Minimum Characteristic Resistance Force (F') as determined through field testing in compliance with Metro - Dade Counry Protocol PA 105. I(F', as tested, is less than 275 lbf., insulation attachment shall not be acceptable. 12 Asphalt moppings shall be applied with approved asphalt and shall be in compliance with the equiviscous temperature (EVT) methods of asphalt determination. Asphalt containers or bulk ticks shall indicate an EVT, finished blowing temperature (FBT) and flash point. Asphalt Types and temperature ranges shall be in compliance with Subsection )403.4(A)(3) of the South Florida Building Code. • Insulation may be applied in multiple layers. The first layer shall be attached in compliance with the Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approves asphalt applied within the EVT range and at a rate of 20 - 40 lbs. /sq., or mechanically attached using the fastening pattern of the top layer. Refer to manufacturer's literature and/or the NRCA Roofing and Waterproofing Manual for correct application procedures of insulation panels in approved asphalt or adhesive, which shall comply with the provisions of M PA 117. n;pp Standard Product Control No.: 97- 0520.0 1 . 30 oaga -Plans trance - .cJ uct Con:ro! D:. Product Control No. 9.1-0520.01 '' All standard ' Insulation panels sizes are acceptable for mechanical attachment. When applied approved asphalt, panel size shall be 4' ,• 1.5 In recovery applications, 4' maximum. Pplications, prior to•the application, all existing roof surfaces used as a bonding shall be tested in compliance with Iv1eo•o.Dade Coun ry Protocol PA . 124 for uplift resistance. Test pressures shall be calculated in compliance with the wind load r equirements of substrate Florida Building Code for the roof in question. a pplications. 16 In re- roofing a Chapter 3) ot' t h e South ions. moisture content in an existing roof must be in compliance with l 7 (m), (n) of the South Florida Building Roof goods shall be stored on end and on a cle flat S�o;ec;;,;; 13 If required. any Facto surface. Factory Mutual q flat and dry adhesives may be used prior PProved vapor barrier in conjunction with proprietary or approved t application of the insulation layer. 19 Consult current Underwriters Laboratories Directory for the ass to r obtain the required fire mete Subsection 3o01, h appropriate l be intal coating for each compliance wiih roofing ,. The assembly shall be installed in strict complianc S and 3401.6 of the South Florida Building Code for maximum tire classification. 31 uloaga•Plans` -, rant 4vdUCt Control Di.. CS Roofing Products Company, Inc. 5535 MacArthur Blvd., Suite 900 Irving, Texas 75033 Product Control No.: 97.0520.01 . ACCEPTANCE NO.: 97- 0520.01 APPROVED: June 19. 1997 _ EXPIRES: June 19. 2000 NOTICE OF ACCEPTANCE STANDARD CONDITIONS Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submined documentation, including test supporting data, engineering documents, are no older than eight (8) years. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement. "Metro -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3 Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) if the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5 Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product. for sales, advenising or any other purposes. 6 The Notice of Acceptance numbeC preceded by the words Metro -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7 A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9 This Acceptance contains pages 1 through 32. END OF THIS ACCE 33 Product Control Div. 1 Membrane Type: SBS MODIFIED Deck Type l: Wood. Won-insulated Deck Description: '" / or greater plywood or wood plank decks System Type E: Base sheet mechanically fastened. All General and System Limitations apply. Bast Sheet: Fastening: Ply Sheet: Membrane: Surfacing: Maximum Design Pressure: -45 psf Maximum Fire Classification: Class 'A'; see General Limitation 4'2. Maximum Slope: I:12; see General Limitation 4'3. Specification No.: GMS 2 -3, FRP 2 -3, GTS 2 -3. FRBC 2 -3 One ply of GS Glas Base, GS Flex -I Glas Base. Flex -I Glas FR Base or GS Poly SMS base mechanically fastened as detailed below. Base sheet shall be lapped 4" and fastened with approved roofing nails and tin caps 9" o.c. in the lap and rwo rows staggered in the center of the sheet 12" o.c. (Optional) One ply of GS Glas Base, GS Flex-I-Glas Base, Flex- I -GIas FR Base. GS PoIySMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type V1) adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq.. Onc ply of Flintlastic GMS, Flintlastic Premium GMS, Flintlastic FR - Flintlastic Premium FR -P, Flintlastic FR -PG or Flintlastic FR Cap adhered to base or ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 w 40 lbs. /sq. or Flintlastic GTS torch adhered to base or ply sheet (Optional) Install one of the following: 1. 400 IbJsq. gravel or 300 lbisq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb. /sq.. 2. Karnak 97 or APOC 212 Fibrated Aluminum at an application rate of I % gal. /sq.. 27 Product Control No.: 9 0520.01 -A Frank Zuloaga -Plans Examiner. Pro' uct Control Div. • ROOFING SYSTEMS (TGFU) — Cont One layer 'Flinttastk GTA (•3/4 sq or •1 sq), GiS' (modified :r.e•n), dear Juseo or "F11ntlasric GMS , hot mopped. : :i cinp: APOC 'No. 212 Fibradod'Aluminum•, at 14/2 gal. 100 start. • nC incliner 3/4 Retarder (Optional): Type G2 'Glasbasc base .sheet or UL "! :isillee vapor retarder. :a•rtation (Optional): One or more layers or combination of the following: U(tragard Premier, polyisocyanurate. pertite..glass fiber or oee fiber insulation. 33se Sheet. One layer.of Type G2 "Cslaibase" base sheet. ternbrane: One layer of "Ftintlastic STA (modified bitumen), heat fused. Karnak "No. 97 flbrated Aluminum", at 1 -1/2 gaL per 100 Incline: 1/2 .••lesion (Optional): Schuller International "UltraGard Premier. :ui;'i ;oryanunte, wood fiberboard. perlite, fiberglass. (socyanurate, any ;: Sheet: One or more plies of'Glasbase ", hot mopped or mechanically Xenia. • • •tar::brdne: One ply oi'Flintlbstic FR' (modified bitumen), hot mopped in Incline: 1/2 olation: Potylsocy'an glass fiber, perllte, wood fiber, hot mopped mechln!caUy fastened, any thickness• • • _:se Sheet: Type G2, mechanically fastened or hot mopped. "Flintlastic GTA or SEA', heat fused. ;.r. 'asing: henry Co. "Henry 520 Aluminum', applied at 1 -1/2 gal/sq. •' :� : :C. Incline: 1/4 (0pctonal) :•Glass Ober, perlite or wood fiber board. Sheet:. Type G2. mechanically 'fastened. •• 1 :rang: 'FlInt!astic STA', 'VA', 'GTA Black Diamond' or 'GTA lVhite heat fused. . _.'acinye. Karnak Chemical Corp. 'Karnak No. 97'. 1 gal/sq. hornet 1 !rs•ation: Pat isocytnurattit glass fiber. polite, wood fiber, mechanically : astened er adhered with hot roofing sphalt, any thickness. o Sheet: Type 62, mechanically fastened or adhered with hot roofing •:er:brane: 'FllntLastic GMS', 'GM5 Premium ", adhered with hot roofing '.u:f3cin : Karnak Chemical Corp "Karnak No. 97 fiibrated Aluminum :;.;halt Roof Coating, 2 -1/2 gal /sq. • C•15/32' Incline: 1 •<'•!; joints blocked with 2x4's. _.:; cation: Glass fiber, perllte, 3/4 in. min, joints in insulation must be •' =t 6 in. nom joints in deck, mechanically fastened. •: sv ;heat: Type G2. mechanically fastened or adhered with hot roofing a;m-lt •:tmbrane: "Flintlastic GMS', adhered with hot roofing asphalt. >sfi'cia : Karnak Chemical Corp. 'Karnak No. 97 Fibrated Aluminum ••i`a!t Roof Coating', 2-1/2 gaVsq• h C Incline: 1/2 ::a !ation: Polyisocyanurate, glass fiber, partite, wood fiber, mechanically ~:•aned or adhered with hot roofing asphalt, any thickness. stew Sheaf= Type 62, mechanically fastened or adhered with but roofing • rs rare: "}ltnt!astic STA ". 'GTA', 'GTA Black Diamond' or 'GTA White neat fused in place, Karnak Chemical Corp. - Karnak No. 97 Fibrated Aluminum rP Coating ". 3 gal/sq. Indicter 1 (0 tional - PtrlJt>~ glass :fine, olyurethane, isocyanurate, canlbination isocyanur : te/ partite, po Aj .ethane /pct' .wood any thickness. hot mopped or nailed. _ . _:n :•cane: " Flinclastic STA', 'GTA', "GTA Black Diamond','Flintlastic GTA Diu:tond', "Ge 'GM5 - 514', 'GAS Double Coverage' or 'GMS ' :ernivm', heat fused or hot mopped in place. _•atin•: Grundy Industries, Inc. 'al MB Aluminum Roof Coating' at 1 :2 •:van, •• C•15/32 lading 1/4 • ' 's is ion (0pdonal): Any thickness polyicocianuratt. glass fiber or :•:iitc, rn :harltally fastened, joints In insulation must ba offset 6 in. joints in deck Sheet: Type. G2 base /ply sheet, mechanically fastened' or hot Sheet: Type G2 bases/ply ahcit, mechanically fastened or hot • ;;2cd. i : . it ors r. e: ' nil Ida stic SSA", 'GTA White Diamond' or "OA Blade Diamond'. ;_ Grundy's'al MB Aluminum Roof Coating' at 1 to 2 gal/sq. Incline: 1/2 .•.:_cation (Optional): Polyisocyanurate, glass fiber, perllte, wood fiber, combination, any thickness, mechanically fastened. • . • ROOFING Sl'STEN.S (TGFU) — Continued Base Sheet: Type G2, "Flex•! -G'as FR' or'F!intl:.stic FR Oast', mechanicit fastened or adhered with hot +oofing asphalt. Membrane: 'flinclastic FR•P', 'Flintlsstic Prcrniuna FR: 'Flintlastic- FR /PG' or 'Flintiotic FR.Cap adhered with hot roofi asphalt. • 12 Deck: C•15/32 Iodine: 1/2 'All joints in deck blocked •rith 2x4's. • Insulation (optional): P•slylsocyanur te, glass fiber. partite, combination. any thickness mechanlcaUy fastened. ,Rasa Sheet: Type G -2, mect•anicaUy fastened or adhered with hg t asphalt, • t ' • j.o, � ;V l ;. Membrane :'FUGltlastic FR- P", 'Flintlastic Premium FR- P",or'fUntia, FR/PG v adhered with hot :oofing asphalt ,V t eck. \�NC ln :iine 1/2 * . :P" ., insulation •(optional): E'S. any thickness. covered with 1/2. ire-- polite or wood fibe:. mac hanically fastened_ • ;t; ; et Base Sheet: Type 62. me, tonically Jaaened or adhered with hot{q r asphalt. .11' Membrane: - Flintlastic Ft•P', 'Flinttastic Premium FR -F' or'Jli 14 'fR /PG', adhered with hoc roofing asphalt. :rt 1' t 14. Deck, NC Incline: 1/2 .i S- . • Insulation:. Polyisocyanurate, .glass fiber. partite. wood - fibs..,..:. combination. any thickc.e.ss, lnechanicat1yy fastened. , ...F j� • Base Sheet: Type G2 os 'Flex adhered •with:ho�roofin : :� ,) f Ply Shce`PotySMS 835e Sheet'. adhered with 'hot roofing:ii - p ' Membrane: "CMS', adhered with hot roofing asphalt r ::.,;' -' sg, t Surfacing: Karnak Chemical Corp. 'Karnak No. 97' Fibrated- -A�' Asphalt Roof Coating" at 2.1/2 9aVsq• • ';;,;,rr,,ref/ 15. peer NC lnctioc 1/4 i•,? ' • Insulation (Optional; : Polyisocyanurate. glass fiber, pertite,'wii. ; :�" s s ' ' • _ any combination. any thickness, mechanically fastened or adtie hot•roofing.asphalt. • -: ai tP. Base Sheec Type 62 or• "Flex•i•ylas', mechanically fastened∎orp. with hot roofing asp laic- • qty.?: Ply Sheet (optional): Type G2 or 'flex - i glas', mechai iii _:,,(r' adhered with hot roafing asphalt. : : _ .s : ' Membrane: "Flintla: lic CMS', 'CMS Premium', adhered with.ho at�, �� , ..,, asphalt. ' •:, „ ' t , 41t • Surfacing: Asphalt Products Oil Corp. 'APOC-400 SunbriCe, ?3 :gak'hrily r 16. Deck: C -15/32 Ioci im 3/4 :r' ' ;!4 Insulation: Glass fiber, perllte, 1 in. min. joints in irlsulalio' 1;411; offset 6 in. from j sink in deck, mechanically fastened.. '.i; Base Sheet Type G2 o 'Flex- 1•glas ",.mechanically festened;'o with-hot roofing ; sphatt. :�: �j %. r '„i; Ply Sheet (Opt roofing Type G2 or "Flex i - glu'. mechanically:. . - :''T adhered With hot roofing asphalt r r 5 :. • p�Ai'� Membrane: 'Flin'dastic CMS'. 'GMS Premium', adhered wit asphalt_ ,; 3 e • .. Surfacing: Asph:dt Products Oil Corp. 'AFDC - 400 SunbriLetfi ` .�° � t.k3 f � 15 % s 1l. Deck NC lnctinc 1/2 • •.. ^.,r:: 1t�1.4` /40: Insulation (Optional): Putyisocyanurate perllte,• glass 4 • Base Street: One or more layers of Type G2 or "Flex -i-g s a t j fib any thtdalass, m�'thanicaUy fastened or hot mo ped ti i „' t ��i r C��� tit' ' • se r ru a'f4 fastened or hot mopped in place . - =t �s"►; 4 �Y,�� Pty Sheet (Optional): One orrnore layers or Typo GI, G2'oi a fi :t�FYi mechanically frstened or hot mopped in pbce. "• "' r.% i r. : ,, ;■ Membrane: Fintlastic GTA', 'GTA Black Diamond' "GTA W e i'••'' ;,� or 'STA', heat fused. ; . 5 : ::.• �. , . 1 .4 1I � l ts , Surf:Kin : Karnak Chemical Co. 'No. 97' applied at'1 =1 y: ` ; i ; i: :11} ? , 18. Decio NC • • ' Incline: 1/4 • "' ,' w�T c�' ", Insulation (Optional): Pcrtite, glass fiber, mechanical • j;� st ; .r ; mopped in pace, 2 in. max thitkne . • .,. , sitkY .; + � j�t ' Base Sheet: One or more layers of Type 62 'Flex -i-91a ,. •y, - •_.(ened or not mopped in place. :' =? 1' ; yA'1rri� Ply Sfilbt One or more layers of Typo G1 11 d ; • • or 'Poly St't. Base Sheet', melhatiicaU Y fastene,e1 or hot srio P. r ' sk : i!, ' , , 5, . ; Membrane: "GTA', 'LTA Black Diamond', 'GTA WhT[e•Ofam• • . `;'�1,,. S' heat fused • • - . WTiFf{,41 ; •� Surfacing: APOC No. 212 Aluminum Coati n . t :+4 eck C -15/32 lndlne. 1/2 •:•••;.k' ;= 6{�'. Insulation: Glass fiber or perllte. min 1 in. thick meth r or hot nacpped in puce. Y,4, •C 1 - `oast She A: Type G2, "Flex- I -Glas' or•flex -I -Gies FR Bass' i ,�y�;"Y fastened or hot mopped in place. : " ;t ;; • • Ift: Membrane: "flinl'lastic FR -P-, 'Flindastic Preraiunt FR•F," oVi% • • •,1 FR/PG', lot mopped in place. s _ 20. Deck NC !.,dine 2.' .lilt ry ~er 't•i;'el r,. ,ik lk : Insulation (Optional): Partite, glass fiber, polyureth�ry ,a ;. phenoli,, combination ssocyanurate /perlite. potyureth „ ..��•�<, �jrl' :;;� fiber, a +y. thickness, mechanically fartoned or hot nldgQ ; :HF•;Sif3 , • Base Sheet'Flex- I -Glas FR Base', Type G2 or "flez�l•GG � ffKf '. fastened of hot mopped in place fie LOOK FOR MARK ON PRODUCT •• • Membi •FR•r' N. peck:. C-' Jn;ula or hot Base Memb Dcci: C• Insul' comb: mutt Base :aofil Base Ply . 63:e Heft Ccrs.: tnsl fast Bas aun • 'Ell 10I 9 x, Co :T. In 1 Ci;`� Application is hereby wade for the approval of the detailed statement or we plans and specifications herewith submitted for the build ine or other structure herein described. This application Is made in compliance and conformity with the Building Ordinance of Miami Shores Village. Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications roust be kept at building during progress of the work. Owner's Name and Address /77 / . E L I(E 6 Registered Architect and /or Engineer .,., Name and address of licensed contractor - 7;70,e R. LWwc Eat Fr % - e Location and legal dcss Lion of lot to be built on: Lot 7.114.1./ Street and Number where work is to be done ./ 0 !v . Etrf ..,..__ State work to be done and purpose of building (by floors)..._ Ferro 1= �j'E('/ w - 'fie L /7 .4_ l7 f S ��ycs S�l2o/ f 5. ._...�ILL� � Id. S 4 J!i/(E S u j i T l// Gri'xivF L. 7— ( g L S'c u »fE'S New Building Remodeling Addition To be constructed of Kind of foundation Estimated Total cost of improvements $ 00 Amount of Permit S.. Zone cubage required plan Cubage Distance .to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to.. The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the 'Florida \Vorknnen's Compensation Act, being Section 5e966. Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in tl:c work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as arc required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this pennit, as are licensed by Miami Shores Village. Remarks STATE OF FLORIDA, COUNTY OF DADE. ss. APPLICATION FOR BUILDING PERMIT Building Inspector Chairman Member \tembcr _....._......_..._._ sass. Council Approved MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT l Subdivision w r? TFirS B — 12._ 1 �... a made for making corrections Date..._... D _..__._..._._ ... ,19.. 9 sass . Street!... and for no other purpose. Repairs No. of Stories Roof Coverings, ",' 56 5'. J'/ -4 ( Signed ) _ a/Y.Y.1k- ..f' ) PLANNING BOARD DATE Member Member Member Date Disapproved Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true.. Permit No.._ � . .44 Date Disapproved (Sig Read, Sworn to and Subscribed before me. Notary Public, State of Florida My Commission Expires or changes to this application after approval NOTE: A ch.rrge of $1.00 will be the 1'I.rnnir.,. Board. A re-inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice materials anti /or workmanship. o ,p/ to me well known, Date has been obtained from for inspection or faulty I ft,/ , (AL Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build in or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Addres Registered Architect and/or Engine Name and address of licensed contractor.846 Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done State work to be done and purpose of building (by floors)._ Disapproved (Signed) APPLICATION FOR BUILDING PERMIT gg.5 MIAMI SHORES VILLAGE // BUILDING INSPECTION DEPARTMENT Building Inspector Date..—..., 19..__ 6- 7 -121'dir tzq Streeta: IZAA-Clfeg- " ""/ "II _Nail and for no other purpose. New Building Remodeling Addition Repairs 1" No pries 1 To be constructed of Kin of f undation. Roof Covering. /%--U Estimated Total cost of improvements $. 7; 0 'mount of Permit $. Zone cubage required _Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub-contractors employed by him in the work to be performed tinder this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required hy the Act. The undersigned agrees to employ only such s 4conracoy, oi to be p3ia rrnea under this pennit, as are licensed by Miami Shores Village. Remarks (Signed 5: 6 / STATE OF FLORIDA, COUNTY OF DADE. ss ' Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has car ully r ad the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit Date Read, Sworn to and Subscribed before me. Notary Public, State of Florida My Commission Expires to me well known, PLANNING BOARD DATE Chairman Member Member Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained fmin the Planning Board. A re-inspection fee of S1.00 will be charged when such re-inspection is made necessary by improper notice for inspection at faulty materials and/or workmanship. MIAMI SHORES VILLAGE, FLORIDA BUILDING ❑ DATE •-• 4 3/ 19 ELECTRICAL ° PT PERMI PLUMBING n N ° 5294 Contractor's License No. �° � 6 ROOFING •,,,_, ❑ Work to be performed under this Permit } ` Owner of Building Architect Contractor or Builder Legal Lot Description II Bl Address of - Value of II Amount of -- Building / / / - j - / / • - Project $— II Permit $ • ` This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the applica- tion herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes respon- sibility for work done by his agents, servants or employees. Signed . INSPECTOR In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In ao cepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. CONTRACTOR OR BUILDER • �'- . .'t$.: r BY Subdi- vision AUTHORITY ABBOT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Owner's Name and Addre Registered Architect and /or Eng te, Name and address of licensed dontractor a"1 ""` Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done / ® 6 .' State w k t be=y1 purpose of . uilding 7 floors) ` Date /r , e � T _ No / D e 7 Street nrr azy - /For cJ, - and for no other purpose. New Building Remodeling. Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Covering Estimated Total cost of improvements $ Amount of Permit $ ca Zone cubage required plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5986, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub- contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the wor such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be .lformed under this permit, as are licensed by Miami Shores Village. Remarks (Signed) STATE OF FLORIDA, COUNTY OF DADE. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No.`' Date..-5 Coi Read, Sworn to and Subscribed before me. Disapproved Date (Signed) uilding I ector Notary Public, State of Florida My Commission Expires PLANNING BOARD DATE Chairman Member Member ..- Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship.