Loading...
CC-10-2259 (2)sr): C B'S. 0zo 4oc.PQN CHC/ 1/3.0:' "6,1411. '40NING,,ZONED STREET LINES, SET. AE1,CS, `UNDERGROUND EASEMENTS AND ; RJCHT: OF : 'WAYS,:' ETC. FROM tABSTRA tT.TO BE VERIFIED AND /OR' ': :CBTA(NE ; BY OWNER, ARCHITECT-' OR BUILDER- BEFORE- :DESIGNr OR: CONSTRUCTION.: ST. ROSE OF LIMA GRADE SCHOOL MIAMI SHORES, FLORIDA CONVENT BULDI G - SECOND L O DRYWALL AIRS 10500 NE 5TH AVE. MIAMI SHORES, FL 325 Meridian Ave,, #14 Miami Beach, Florida S3139 p,305 -409 -9959 rsbarch @hotmaH.com DRAJV1NG INDEX ARCHITECTURAL DWG* DRAWING TITLE TITLE PAGE LS1 TYPICAL DIMENSIONS, ABBREVIATIONS, AND LIFE SAFETY PLAN D0.1 SECOND FLOOR DEMOLITION PLAN A1.1 SECOOND FLOOR RENOVATION PLAN AND WALL TYPES ISSUED FOR BID & CONSTRUCTION DATE: 01/25/2011 ROBERT BROWN ARCHITECT LICENSE # AR92624 16 CODE REQUIREMENTS BUILDING CODE /HANDICAPPED REGULATIONS COMPLIANCE SUMMARY 15 14 I 13 12 11 THE WORK PROPOSED IN THIS PROJECT IS SUBJECT TO 2007 FLORIDA BUILDING CODE, REGULATIONS REFERENCED THEREIN AS WELL AS FLORIDA REGULATIONS. THE WORK PROPOSED IS DESIGNED TO MEET CODE PROVISIONS DETERMINED TO BE APPLICABLE IN TI-E COURSE OF OUR PROFESSIONAL SERVICES. THE FOLLOWING BUILDING CODES WERE USED: FLORIDA BUILDING CODE 2007— WITH 2008 AND 2009 SUPPLEMENTS. FLORIDA ACCESSIBILITY CODE — FLORIDA BUILDING CODE CHAPTER 11 FLORIDA FIRE PREVENTION CODE — 2007 THE USE GROUP IS R-2. SCOPE OF WORK ALTERATION LEVEL "REPAIR" PER 2007 FLORIDA BUILDING CODE, EXISTING BUILDING, CHAPTER 4 CONSTRUCTION TYPE: IIIB, UNSPRINKLERED, PER F.B.C. 2007 CHAPTER 6 SCOPE OF WORK TO INCLUDE DEMOLITION OF EXISTING DAMAGED DRYWALL. REPAIR TO INCLUDE REPLACEMENT OF DRYWALL. GENERAL NOTES 1 ALL WORK PERFORMED SHALL COMPLY WITH THE CONTRACT DOCUMENTS, DRAWINGS AND SPECIFICATIONS, INCLUDING THESE GENERAL NOTES. THE CONTRACTOR SHALL COORDINATE THE INTENT OF THE GENERAL NOTES WITH ALL TRADES. 2. THE ORGANIZATION OF THE DRAWINGS AND SPECIFICATION SHALL NOT CONTROL THE CONTRACTOR IN DIVIDING THE WORK AMONG THE SUBCONTRACTORS OR IN ESTABLISHING THE EXTENT OF THE WORK TO BE PERFORMED BY ANY TRADE UNLESS SPECIFICALLY REQUIRED. 3. THE MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE DRAWINGS AND SPECIFICATIONS. IF CONFLICT IS FOUND BETWEEN DRAWINGS, GENERAL NOTES, AND SPECIFICATIONS, CONSULT THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. 4. THE STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF STRUCTURAL, MECHANICAL, AND ELECTRICAL WORK. SHOULD THERE BE A DISCREPANCY BETWEEN ARCHITECTURAL DRAWINGS AND THE CONSULTING ENGINEERS' DRAWINGS, IT SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION BEFORE INSTALLATION OF SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST. 5. DO NOT SCALE DRAWINGS; DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON DRAWINGS. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS, GRADES AND CONDITION AT THE SITE PRIOR TO COMMENCING WITH THE WORK, AND REPORT ANY DISCREPANCIES TO THE ARCHITECT IN WRITING. 6, ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED TO BE CONSTRUCTION STANDARDS. IF THIE CONTRACTOR HAS QUESTIONS REGARDING THE SAME, OR THEIR EXACT MEANING, THE ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION. 7. WHERE A TYPICAL CONDITION IS DETAILED, IT SHALL BE UNDERSTOOD THAT ALL LIKE OR SIMILAR CONDITIONS ARE THE SAME UNLESS SPECIFICALLY NOTED OR DETAILED OTHERWISE. 8. ALL DIMENSIONS ARE TO FACE OF FINISH UNLESS OTHERWISE NOTED. 9. CEILING HEIGHT DIMENSIONS ARE TO FINISHED SURFACES. 10. ALL CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE FLORIDA BUILDING CODE. 11. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL STIFFENERS, BRACING, BLOCKING, BACK -UP PLATES, AND SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF ALL CASEWORK, TOILET ROOM ACCESSORIES, HAND RAILS, CHAIR RAILS, FIXTURES, AND PARTITIONS, AND ALL WALL MOUNTED OR SUSPENDED MECHANICAL, ELECTRICAL, OR MISCELLANEOUS EQUIPMENT AND FURNISHINGS. ALL WOOD BLOCKING SHALL BE FIRE- TREATED. 12. MECHANICAL SUPPLY AND RETURN AIR SHAFTS SHALL BE AIRTIGHT AND SEALED. 13 THE CONTRACTOR SHALL REVIEW THE LOCATION AND THE MOUNTING HEIGHTS OF THE TOILET ROOM ACCESSORIES WITH THE ARCHITECT AND THE BUILDING INSPECTOR PRIOR TO INSTALLATION TO ASSURE CORRECT POSITIONING IN ACCORDANCE WITH THE AMERICANS WITH DISABILITIES ACT. 14, PENETRATIONS IN WALLS, FLOORS, OR ROOF REQUIRING PROTECTED OPENINGS SHALL BE ARE STOPPED IN ACCORDANCE WITH NFPA. 15. ALL LEGAL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, OR ANY SPECIAL KNOWLEDGE OR EFFORT, AND SHALL SWING IN THE DIRECTION OF EGRESS/ SPECIAL LOCKING DEVICES SHALL BE AN APPROVED TYPE. ABBREVIATIONS ABV @ ACOUS ACT AFF ALUM BLDG BLKG B.O. ABOVE AT ACOUSTICAL ACOUSTICAL CELING TILE ABOVE FINISH FLOOR ALUMINUM BUILDING BLOCKING BOTTOM OF FEC FF FIN FL FOS FOUND FT GALV GL. FIRE EXTINGUISHER (CABINET) FINISH FLOOR FINISH FLOOR FACE OF STUD FOUNDATION FEET GALVINIZED GLASS / GLAZED MTD. NIC NTS OC OH OPNG OPP P LAM PLAS MOUNTED NOT IN CONTRACT NOT TO SCALE ON CENTER OPPOSITE HAND OPENING OPPOSITE PLASTIC LAMINATE PLASTER VCT VINYL COMPOSITE TILE VEND VENDING VERT VERTICAL VIN VINYL VNR VENEER W/ WITH WD WOOD WNDW WINDOW YD. YARD B.O.W. BOTTOM OF WALL GD GRADE PL PLATE B.O.W.F. BOTTOM OF WINDOW FRAME GR FL GROUND FLOOR PLYWD PLYWOOD CER CERAMIC GWB GYPSUM WALL BOARD PTD PAINTED CHAN CHANNEL GYP GYPSUM REQ'D REQUIRED CJ CONTROL JOINT HC HANDICAPPED RM ROOM c CENTER LINE HDR HEADER RO ROUGH OPENING CLOS CLOSET HDWD HARDWOOD SC SOLID CORE CL. CLEAR HOR HORIZONTAL SER SERVICE CMU CONCRETE MASONRY UNIT HT HEIGHT SHT SHEET C.O. CENTER OF INSUL INSULATION SIM SIMILAR COL COLUMN JAN JANITOR SPEC SPECIFICATION CONC CONCRETE JNT JOINT SS STAINLESS STEEL CONT. CONTINUOUS KIT KITCHEN STOR STORAGE CTRSK COUNTERSUNK LAM LAMINATED STL STEEL CT CERAMIC TILE / CURTAIN TRACK LCC LEAD COATED COPPER STRUC STRUCTURAL DWG DRAWING LOC LOCATION SQ SQUARE DN DOWN MACH MACHINE TEL TELEPHONE EL ELEVATION MAS MASONRY TO TOP OF ELEC ELECTRICAL MFR MANUFACTURER TOC TOP OF COPING / CONCRETE EMER EMERGENCY MECH MECHANICAL TODF TOP OF DOOR FRAME EQ EQUAL MIN MINIMUM TOS TOP OF STEEL EXP EXPANSION MISC MISCELLANEOUS TOW TOP OF WALL EXT , < EXTERIOR MO MASONRY OPENING TOWF TOP OF WINDOW FRAME EXIST. EXISTING MTNG MEETING TYP TYPICAL FD FLOOR DRAIN MTL METAL UNO UNLESS NOTED OTHERWISE 10 11 BEDROOM 201 0 36" EXIT DO R MEcH, STAIRHALL I TOILET 202 BEDROOM 217 BEDROOM 203 BEDROOM 204 216 BATH & SHOWER 0 CC I: 0 U 215 O_ N TOILET 214 205 206 16 207 213 BIEDROOM 212 208 ® 36" EXIT DOO BEDROOM 209 211 LIFE SAFETY LEGEND ® SMOKE DETECTOR EXIT LIGHT (DIRECTION OF EXIT) o RPE EXTINGUISHER CABINET MOUNTED le amess • moms seam= s comma o ammo cum= DENOTES LMT OF PROECT SCOPE LIFE SAFETY GENERAL NOTES DOSING LIFE SAFETY SYSTEMS AT CONSTRUC11ON NOT TO BE MODIFIED BY THIS PROJECT. ILLUMNATED EXIT SIGNS LOCATED ON RRST FLOOR AT THREE EXTERIOR EXIT LOCATIONS. EXIT SIGNAGE NOT REQURED FOR TI-E SECOND FLOOR PER R3C. PER FBC 708.1 -7, RATED WALLS ARE NOT REQUIRED. APPROVE!) 1 •SPK ^. PERMIT 1OI�' 'ITE PD si ION1 Or 0.� Y ` 'E .' T_11A� I CT E 1EPLORI- AF1 EP A16 PROJECT INFORMATION NOT TO SCALE A09 SECOND FLOOR LIFE SAFTEY PLAN SCALE 1/4' =1'-0' 16 15 14 13 12 11 10 ISSUED FOR BID AND CONSTRUCTION DATE: 01/25/2011 ROBERT BRO ARCHITECT AR 92624 LLI LIJ 0 cry 325 MERIDIAN AVE., #14 m MIAMI BEACH, FLORIDA 33139 P.305 -409 -9959 — RSBARCHPHOTMAIL.COM () goa 0 au.. j O oft <c, L 5 W WI. ®I to- ® OW O < ® act Z 11-1 c)° (/J d✓ PP VJ P cles w scut- 0 m ELI NORTH ND DESCRIPTION DATE 1 AHCA Rations 2 10.27.10 3 4 5 6 7 8 JOB NQ 2011 ®01 DRAWN BY CHECKED BY RB RB DATE SCALE 01/25/2011 AS NOTED SHEET N Q L 1 16 15 I 14 13 12 11 10 L G F E D A BEDROOM 201 TOILET 202 J BEDROOM 203 BEDROOM 204 L _ BEDROOM F205 BEDROOM 206 r — z - BEDROOM— • — 207 BEDROOM 208 -� t BEDROO 209 0 0 U N ME H. STAIRHALL 2 DN. I I� I` � 1 T — i BEDROOM 217 1 BEDROOM 216 JAN. L - J r L BATH & SHOWER 215 1 TOILET 214 i - J BEDROOM 213 BEDROOM 212 CL,I 1. L STAIRHALL ,,{ DN. BEDROOM 211 DEMOLITION LEGEND ° • ® • — DENOTES LIIVIT OF WORK LINE DENOTES EXISTING WALLS — — — DENOTES DRYWALL TO BE REMOVED - EXISTING STUDS TO REMAIN. DEMOLITION PLAN GENERAL NOTES 1. ALL EXISTING ELECTRICAL, PLUMBING, AND MECHINCAL DEVICES TO REMAIN. 2 ALL CEILINGS, DOORS, BASBOARDS, AND FLOORING IN PROJECT AREA TO REMAIN UNLESS OTHERWISE NOTED. 3, ALL EXISTING DAMAGED DUCTWORK, GRILLES, AND REGISTERS TO BE REPLACED, /.[ DADE CO ati DE 1� A10 SECOND FLOOR DEMOLITION PLAN SCALE 1/4•=1' -0' 16 15 14 13 12 11 10 8 7 6 5 4 ISSUED FOR BID AND CONSTRUCTION DATE: 01/25/2011 ROBERT B WN ARCHITECT AR 92624 LU LU 0 co - 325 MERIDIAN AVE, 4114 m MiAM BEACH, FLORIDA 33139 0 v P,305 -409 -9959 RS8ARCH@HOTtviAIL.COM 4.1 0 E 511- 0 < <0 11.5 W OM IL CC 1.00 I cD zo OW 0 82 0 Loot W ®® V DEMOLITION PLAN ND DESCRIPTION DATE AHCA Rations 10.27.10 CHECKED BY RB RB SCALE AS NOTED D1.1 K J B A 16 15 14 13 12 11 10 9 8 RENOVATION LEGEND ® • ® • ® DENOTES LIMIT OF WORK LINE BEDROOM DENOTES EXISTING WALLS BEDROOM DENOTES NEW 5/8" DRYWALL ON EXISTING STUDS - SEE A03/A1.1 FOR DETAIL. BEDROOM DENOTES ROOMNAME AND NUMBER RENOVATION GENERAL NOTES 1. ALL EXISTING ELECTRICAL, PLUMBING, AND MECHINCAL DEVICES TO REMAIN. 2 ALL CEILINGS, DOORS, BASBOARDS, AND FLOORING IN PROJECT AREA TO REMAIN UNLESS OTHERWISE NOTED. 3. ALL EXISTING DAMAGED DUCTWORK, GRILLES, AND REGISTERS TO BE REPLACED. BEDROOM BEDROOM BATH & SHOWER TOILET BEDROOM THE FOLLOWING LIFE SAFETY FEATURES A L BE PRQV AT ME QFICCt1PANCY: ISSUED FOR BID AND CONSTRUCTION DATE: 01/25/2011 w 0 w 325 MERIDIAN AVE., #14 MIAMI BEACH, FLORIDA 33139 P.305 -409 -9959 RSBARcH1 HOTMPJLCOM () LPL —0 0 Ka: > LL.5 w illJ O c0O L. WI CDZ Z z co OW O ®� > 0 LO ( O BEDROOM BEDROOM 0 or 81111:b1 110S9 sh /41X MI6 THE PROVISIONS OF EXISTING OCCUPANC! ZETFORT IN.TtiE.FLO.PIDA PLR Ei PREVENTION OWE RENOVAT1•N STAIRHALL BEDROO EXISTING CEILING TO REMAIN NEW 5/8" TYPE X DRYWALL - SEE PLAN FOR LOCATIONS ACOUSTIC BATT INSULATION EXISTING WD. STUD TO REMAIN TEMP. REMOVE EXISTING BASE TO INSTALL DRYWALL AND REINSTALL A10 16 15 14 13 12 SECOND FLOOR RENOVATION PLAN 10 SCALE 1/4•=1'-0• 9 8 6 5 4 A03 FINISH FLOORING TO REMAIN :S` No DESCRIPTION DATE m N U 6 I 0 8 JOB NQ 2011 ®01 DRAWN BY 3 2 1 RB DATE 01/25/2011 CHECKED BY RB SCALE AS NOTED SHEET N Q 0 A1.1 ayf MIAMI DADE FIRE RESCUE Process No Marnic >4 :1 Insp No: Name: a ✓e Address: )0500 /' 5 5 _�— INITIAL I EVIE V A pp Mea' Mot Appl low 1�1 ,r Dae. gwI 'T14IS IS NOT A PERMIT. MUST PROP MUNICIPAL INSPECTIO UIPEME t AND RIC' "D CARO AT the TaE OF A FIRE IN-SPEC TIC N. e u1 PLAN RE VIE :.. FINAL APPROVAL R DEPARTMENT OF ENVIRONMENTAL RESOURC ;.S MANAGEMENT CORE REVIEWER (PRINT): SIGNATURE DATE