Loading...
FW-08-1257Project Address 10538 NE 4 Avenue Miami Shores, FL 33138- Owner Information JOHN KURACK Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138-0000 Phone: (305)795 -2204 Address Parcel Number 1122310130200 Block: Lot: 10538 NE 4 Avenue MIAMI SHORES FL 33138 -2014 Phone W Contractor(s) Phone Cell Phone SOUTHERN ENGINEERING CONSTRU (305)251 -3000 Approved: Yes Comments: FENCE NOT TO EXCEED 5 FEET IN HEIGHT Date Approved: 7/11/2008 : Yes Date Denied: 7/11/2008 Type of Construction: Other Classification: Residential Additional Info: ALUMINUM 5 FEET MAX Fees Due CCF Education Surcharge Notary Fee Permit Fee - Wire & Wood Scanning Fee Technology Fee Total: Amount $1.80 $0.60 $5.00 $100.00 $6.00 $2.50 $115.90 Authorized Signature: Owner / Applicant / Contractor / Agent Building Department Copy Wednesday, July 16, 2008 Expiration: 01/12/2009 Applicant JOHN KURACK Available Inspections : July 16, 2008 Date Cell Valuation: Total Sq Feet: $ 2,500.00 160 Inspection Type: 1 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. 1 10bt Ate 9r1joyT BUILDING PERMIT APPLICATION FBC 2004 Permit Type (circle): Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 aS Permit N "— O 1 Master Permit No. Roofing Owner's Name (Fee Simple Titleholder) _._._ D / � �_�f/i'�� / Phone # Owner's Address 064 B ,s/ 4 / 4 ye- City 6 ,77/40—#7/ State Tenant/Lessee Name Zip -Job Address (where the work is being done) / City Miami Shores Village FOLIO / PARCEL # Is Building Historically Designated YES NO_______ s Contractor's Company Name" '4 2.. >m a' r ed,,e3S 7 Phone # Contractor's Address /,fie'' 7 c�/7 C / �' .2� oz � L.LD l' orl9 / CG - � city � r ^ yp State ; t Zip l 3 Qualifier Name State Certificate or Registration No. Type of Work: ❑Addi n ❑Alteration ❑New Describe Work: cfile sue/ Phone # County Miami -Dade Zip _ .. Phone # 78 b +.. 1 ✓ / `r LCD Certificate of Competency No. Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $01.5 4e Squa / L' amp r Footage ork: i epair/Replace ❑ Demolition ill 1 1 2388 B Y: �--- ******** *** ***** ******* *** ******* ****** F ** * * **** ***** * ***** * ** ******* ** Submittal Fee $ Permit Fee $ ef...--, CCF $ CO /CC Notary $ Training/Education Fee $ Technology Fee $ Scanning $ Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ See Reverse side --> Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) • Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. W YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and yeinspection fej will be charged. Signature The fore day of er or Agent wledgec. before me � '`� wh is personally known to me or who has produced own to me or who has produced _`Lidentification and who did take an oath. 4\‘" 4* b A- X9 �k cs 9 �� 1a�r G° S. NOTARY PUBLIC: Plans Examiner Engineer Zoning VILLAGE OF MIAMI SHORES OWNER BUILDER DISCLOSURE STATEMENT NAME: L kv DATE: 7 ADDRESS: �? /,,1 lob" s 7 Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, F.S 489.103(7). And I have read and understood the following disclosure statement, which entitles me to work as my own contractor, I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor. You have applied for a permit under an exception to the law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the construction yourself. You may build or improve a one - family or two- family residence. You may also build or improve a commercial building at a cost of $25,000.00 or less. The building must be for your own use and occupancy. It may not be built for sale or lease. If you sell or lease a building you have built yourself within one year after the construction is complete, the law will presume that you built for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person as a contractor. It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F.I.C.A and with - holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, buildings codes and zoning regulations. Please read and initial each paragraph. 1. I hold title to the above property and I am planning on doing this construction Myself. Initial 2. I understand that as an owner - builder I must abide by all zoning ordinances and building regulations in effect at the time of permit application. Inactive permits for a period of over 180 days will become null and void (expired) and a new permit will be required to be issued for reinstatement of he permit. Initial 3. I have an understanding of the 2004 FBC & FRC and understand that this department and its inspectors are there to help enforce and interpret the code. There is a copy of the code in this office for review. 4. I understand that the building official and inspectors are not there to design, alter or give advice on how to meet code — only if the structure meets the minimum code. 5. I understand that as an owner- builder, that any contractor disputes with sub- contractors and myself must be handled in a civil court with the advice of an attorney. The department will not mitigate any contract disputes. Was acknowledged before me this '" ► day o Produced there License or identification. Planning and Zoning Criteria Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Miami Shores, FL 33138 - Total Job Valuation: $ 2,500.00 Owner's Name: JOHN KURACK Job Address: 10538 4 Avenue NE Owner's Phone: Total Square Feet: 160 Contractor(s) Phone SOUTHERN ENGINEERING CONSTRUCTION LL (305)251 -3000 Planning and Zoning Criteria and Comments Approved: Yes Date Approved: 7/11/2008 : Yes Comments: FENCE NOT TO EXCEED 5 FEET IN HEIGHT Issue Date: Not Issued Permit NO. FW -7 -08 -1257 Permit Type: Fence/Wail Work Classification: Iron /Ornamental Folio Number:1122310130200 Primary Contractor Yes Expires:Not Issued Plat of Boundary Survey Legal Description: Lol Sand the South 1/2 of Lan, Block 11, 'FIRSTADDI77ON PASADENA PARK; =offing to the plait enrol, asleao,ded Rot Book 6, Page 82olth Pubec Roads ofMkunl -Dado Cowry; Florida LEGEND: WDODFEACE WIRE FENCE Fn NAT • MDR MOMMENT 8 RECORD M FIELD MEASURED C CALMATED a aS'R ENCR EN RO0O0ENT LEWERME ® CONE PROPERTYLME CM CMCRETE MOHMmY1 PLR FOUND IRON ROD F.IP. FOPB✓D IRON F'PE RB' RWRNOFWIT NA0 NAIL B MSC DE DRAINAGE EASEMENT OE DRUM EASEMENT E0. FOI/AD P P1AT ARAM ASPHALT O.HL OVEREADWILMS P.P. POWER AXE TX TRAA41FINAER CAW CABLE RISER WA( WATER METER TEL TELEPN0EFACILfiES ® COVERED AREA RR BEAENGRFFERENCE NO LOSTED - ny EASEIMMT _J MN NAM0LE Nut NOTIOSCALE OR OFFICIAL REDS ORB. OFFK7AL RECOROSBOOK P.CP. FEMMB? CORM POINT PRM PERWM'ENTRL:TERENLE1OWUEAR P8 PAGE PVM1. P888181 PE RAT ROOK POE POINT OFBEGNIINO P.00 POINT OP COMMINCEIVElfT P.01 POINT ("NINE PC PONT OF CURVATURE PR0 POWTOF REVERSE ad1VE P 1 pow OFTANDEACY R RAONS(RADML) ROE ROOF OVERHAND MOMENT 8.1R SET MCP IRODS OAP SAY SIDEWALK EOM TELPORARYBEhtc11MARK TOR TOP OF SAM( TYP TW7GAL WC. WRIIESSOOldYAP • • • 0.91' Dafe 05730/2008 •••• • • • • • ge tlfed to: • . • • • Jahn kurack? yl:• • • Tarawa Kura J "' . . • ... ['joperty Address. :0538.& 10440 L11E 4TH AVE. Miami Shores, flor4da 33138 • •• 12 I d' SET1R. 13 'I.R $ PSM# 3761 6 3 3.57' V 0.18' N 89'53'51" W 107.2 al a —Q Ln w e 14 O O O SET 1171.R. PSM 03162 15 U7 A SUBJECT TO COMPLIANC Survey Number: 08 -151 NOTE: IN COMPLIANCE WITH FLORIDA STATUES 61017 -6.0081 (5 )(E), IF LOCATION OF EASEMENTS OR RIGHT- OF-WAY OF RECORD, OTHER THAN THOSE ON RECORD PLAT, IS REQUIRED. THIS INFORMAPON MUST BE FURNISHED TO THE SURVEYOR AND MAPPER GENERAL NOTES: 1) LEGAL DESCRIPTION PROV10(0 BY OT CRS 7 FOUND NA L IN CENIERUNEOF NE 107TH STREET 28.25' STORY o ST GE 28.25' Miami Shores Village PERMIT # PPROVED ONING DEPT LDG DEPT 24.98' • • s FOUND IRON PIPE 0.95 EAST OF CORNER SET 1171.R. PSM03702 C. &M. 107.28 C. &M. ST'S PSM 03762 AL FOUND NAIL & DISC &0,40'NORTH SURVEYORS CERTIFICATION: JUL 1 1 2NO BY: 15.00' 45.00' 0 O O W Q 8. Z E d' O W I STATE AN' C'O PU' li_A FOR REFERENCE ONLY THIS SURVEY IS NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. PHOTOCOPYING FORBIDDEN. COPYRIGHTED MATERIAL. Q IHEREBY CERTIFY THAT THIS BOUNDARY SURVEY IS A TRUE AND CORRECT REPRESENTATION OFA SURVEY PREPARED UNDER MY DIRECTION. 2 • • MECHANICAL ALUMINUM FENCE AT GRADE (NON- STRUCTURAL, DECORATIVE BARRIER, TYPICAL INSTALLATION (GROUND LEVEL ONLY) • SPACED TO REJECT A 4" SPHERE SEE SHEET 2 FOR — ALTERNATE PICKET ARRANGEMENTS • :WLLCONNE.G IONS ....1e)// CAST ALUM. WALE l ETS • • •••• • • •.• • .••• • • ••• • • DETAIL:J L • • • . ••. 11111 r CUZCUI*I*1.Z< L• '•1C (2) #10x%4" SMS (ONE PER SIDE SPACING SHALL NOT EXCEED 1 3/4" P ER FBC 424.17.1. 1 SPACED TO REJECT A 4 " SPHERE (1) #10x134" SMS TYP. (ALT: 1" PI • 4e • •. • • • • •. TOP CAP BRACKET SUBSTRATE 0 0 ^SEE DETAIL 'A' TOP RAIL ASSEMBLY PICKETS MAY RUN THRU OR STOP AT RAILS (7YP. ALL RAILS) 1,1 d BOTTOM 11 CHANNEL "11 STRUCTURE • • 4 d, ,. 4" MAX SPACE AT CONCRETE • • • • • SNAP POST ASSEMBLY OPTIONAL INTERMED RAIL FOOTER SIZED PER EOONR SCHEDULE • • • (RtF. SHEET 2) (Z) #12x% ". SMS 2)34 "x1 EMBED TAPCONS (3" MIN EDGE DIST) SIN 1%4" BOTTOM CHANNEL BRACKET TOP AND BOTTOM BRACKETS TO MATCH TOP CAP AND BOTTOM CHANNEL, RESPECTIVELY 2) #12X34" SMS 2x2x1/8" ALUMINUM ANGLE 2)x% "x1 EMBED TAPCONS (3" MIN EDGE DIST) ALTERNATE RAIL CONNECTION DETAIL (TOP & BOTTOM TYP RAIL) 1 OPEN ./ ALUM. BOTTO CHANNEL #14x SMS EA SIDE OF PLATE 3 % "x3 % "x4 CAST ALUMINUM PLATE ATTACH THE TOP RAIL TO EACH POST WITH (2) #10x1" SMS 5' 0" (1) #10x134" SMS TOP.& BOTTOM (TYP EACH PICKET) MIN. 1" LARGER THAN POST DIMENSION DETAIL 'B' CASTING OPTIONS #14x%4" SMS EA SIDE OF PLATE 4 CAST ALUMINUM FLANGED PLATE BOTTO CHANNEL 3" FULL GUSSET FLANGE ANCHOR OPTIONS: • (4) POWERS WEDGE BOLTS WITH 2" EMBED. INTO CONCRETE 3° MIN FROM ANY CONCRETE FACE ' • (4) 3/B "x6" LAG SCREWS INTO WOOD HOST STRUCTURE (G =0.55 MIN., MOISTURE CONTENT 5 19 %). ANCHOR OPTIONS: • (4) %" POWERS WEDGE BOLTS WITH 234" EMBED. INTO CONCRETE 3" MIN FROM ANY CONCRETE FACE • (4) "x6" LAG SCREWS INTO WOOD HOST STRUCTURE (G =0.55 MIN., MOISTURE CONTENT 5 19 %). OPTIO ED DRILL, : �xy (HILTI CY -150 OR EQUIV) OR HIGH STRENGTH GROUT, 3000PSI CONCRETE MIN. DETAIL 'D' TYPICAL POOL BARRIER INSTALLATION (GROUND LEVEL ONLY, MAY VARY) GATE (QUANTITY & PLACEMENT MAY VARY), SEE DETAIL 'C' NAP POST & SNAP PLATE ASSEMBLY TOP CAP & SNAP PLATE ASSEMBLY EXISTING STRUCTURE '4 4 AIL 'B' MAY RMINATE AT POST, PROVIDED SPACE BETWEEN POST AND STRUCTURE RESISTS A 4" SPHERE ONNECT TO STRUCTURE OR END POST CHANNEL & SNAP PLATE ASSEMBLY • 4 GENERAL NOTES 1) THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2004 FLORIDA BUILDING CODE, FOR USE WITHIN AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE. ALL LOCAL CODES SUPERSEDING THIS CODE SHALL BE CONSIDERED BY THE CONTRACTOR IN DESIGN & MAY REQUIRE ADDITIONAL ENGINEERING. 2) NO 33 Y3% INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THIS SYSTEM. 3) THIS FENCE DESIGN TO BE USED AT GROUND SURFACE ONLY. ITS USE IS LIMITED TO DECORATIVE BARRIER PURPOSES ONLY. THIS FENCE IS NOT INTENDED TO MEET CODES GOVERNING ELEVATED BALCONIES OR STRUCTURAL RAILINGS. 4) ALL EXTRUDED MEMBERS SHALL BE ALUMINUM ALLOY TYPE 6063 -T6, U.N.O. 5) ALL CONCRETE AND EPDXY TO REACH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI IN 7 DAYS. 6) SURROUNDING SOIL TO BE COMPACTED TO 98% OPTIMUM DENSITY, 2500 PSF MIN. 7) PER FBC 424.2.17.1.8: ACCESS GATES WHEN PROVIDED MUST BE AT LEAST 48" ABOVE GRADE & EQUIPPED WITH A SELF CLOSING, SELF LATCHING LOCKING DEVICE NOT LESS THAN 54" FROM BOT OF GATE. GATE MUST OPEN OUTWARD AWAY FROM POOL & MUST HAVE NO OPENING >1/2" WITHIN 18" OF RELEASE MECHANISM. 8) THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALUMINUM MEMBERS FROM DISSIMILAR METALS TO PREVENT ELECTROLYSIS. 9) ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. 10) ANY HINGE AND LATCH SHALL BE STRUCTURAL QUALITY MOLDED POLYMERS AND SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS & ANY APPLICABLE CODES. 11) ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 12) EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. DETAIL 'C' J E LF— CLOSING GATE & LATCH w C7 z x SELF - CLOSING LATCH PLEXIGLASS WHERE RQD 2 X 2 BOX BEAM OR WALL PICKET 1 X 2 HOLL TOP CAP & SNAP PLATE ASSEMBLY TYP. SPACING TO REJECT A " PHERE FRANK L BENNARDO, P.E. # PE0046549 a rk A A s VALID FOR 1 ALE) ONLY MTH RAISED ENG zec (1 t1 0 5� COPYRIGHT FRANK L BMARDGP.E 00 -GMF -1008 SCALE: . 1 . PAGE DESCRIPTION: 101 OF FOOTER DIMENSIONS (DIAMETER X DEPTH) WIND LOAD FENCE HEIGHT 4'-0° 5' -0° 6' -0° 15.0 PSF 125:25° 12"x29° 12"x32° 17.7' PSF 12°x27° 12°x30° 12°x34° 20.0 PSF 125:28° 12°x32° 12°x36° 25.0 PSF 12°x31° 12°x35° 12'x39° 30.0 PSF 12°x37 12°x38° 12°x42° 35.0 PSF 12°x35° 12"x40° 12"x45° 40.0 PSF 12567° 125:42" 12°x47° 45.0 PSF 12°x39° 12°x44° 125x49" 50.0 PSF 12"x41° 12"x46° 12°x52° FOOTER DIMENSIONS (DIAMETER X DEPTH) WIND LOAD FENCE HEIGHT 4' -0° 5 6' -0° 15.0 PSF 12521° 12524° 12°x27° 17.7° PSF 125(22° 12°x25° 12°x28° 20.0 PSF 12°x23" 125:27° 12°x30° 25.0 PSF 12°x25° 125:29° 12"x32° 30.0 PSF 125:27° 12°x31° 12°x35° 35.0 PSF 125(29° 12"x33" 12"x3r 40.0 PSF 12°x31° 12°x35° 12°x39" 45.0 PSF 12"x32' 12°x37° 12"x41° 50.0 PSF 12°x34° 125x38° 12543° MAX FENCE HEIGHT •• r •. POST TYPE WIND LOAD 3° SNAP • HRH POST 15.0 PSF 6'-0° 6'-0° 17.7• PSF 5' -0° 6' -0° 20.0 PSF 5' -0° 6' -0° 25.0 PSF 4' -0° 6' -0° 30.0 PSF 4' -0° 6' -0° 35.0 PSF 4' -0° 6' -0° 40.0 PSF - 6' -0° 45.0 PSF - 5' -0° ' 50.0 PSF - 5' -0° MAX FENCE HEIGHT •• r •. POST TYPE WIND LOAD 3° SNAP • HR-4 POST 15.0 PSF 5' -0° 6' -0° 17.7• PSF ' -0° 6' -0° 20.0 PSF 4' -0° 6' -0° 25.0 PSF - 6' -0° 30.0 PSF - 5' -0° 35.0 PSF - 5' -0° 40.0 PSF - 5' -0" 45.0 PSF - 4'-0° 50.0 PSF - 4' -0° • • • • • .• •••• • • •••• • • • DECORATIvE SPEAR TYP WOW II d II A II d II A II 1WW 11 11 1 11 11 SPEAR TOP •••••FLAT TOP W/ 1 -5/8" SPACING 11 11 1 11 11 11 1 STAGGERED SPEAR A fl 11 11 �RA 11 1 11 11 11 11 CONVEX FOR FENCE DESIGNS OTHER THAN 'C' AND 'E': DESIGN SCHEDULE FOOTER SCHEDULE 11 IlIlIlIlIlIlIlIll 11111 SPEAR TOP W/ 1 -5 /8" SPACING I I CONCAVE 11 11 11 11 FLAT TOP WITH SPEAR A FOR FENCE DESIGNS 'C' AND 'E': DESIGN SCHEDULE FOOTER SCHEDULE A TT 11 11 11 11 11 11 11 11 FLAT TOP i *NOTE: FOR INSTALLATIONS WITHIN THE HVHZ WITH MAX HEIGHT OF 6' -0 ", USE WIND LOAD OF 17.7 PSF, BASED ON 90 MPH WIND SPEED, EXPOSURE C PER ASCE 7 -02 (REF. 2004 FBC 1612.2.1). VALID FOR ( 1 ) JOB : Y VALID ONLY WITH RAISED ENGINEERS FRANK L. BENNARDO, P.E. # PE0046549 a 0 el LL° to O " CO tO J , LL o LL > o - p J3$ 1 Q^0c a o C O ,, G O LL v ILL w L.L. 0 a O N M '- o M E W J O Za+ a B w = ` " X aW > 0 ? LU [Dl0 W ° e4 � CI c g U Z LLI to Nom„ 0 LU z 1 1 1 1 bre IN ihi P COPYRIGHT FRANK L BENNARDO PE 00 -GMF -1008 SCALE: 101 PAGE DESCRIPTION: OF AT GRADE MECHANICAL FENCE •• r •. • • 1 • r • 1 • r • • ••• D r� •I •• • D 41 er• 1 ••r• • • 1 t'I.I11I.II • :i 1111 II II II II II II • • • • • .• •••• • • •••• • • • DECORATIvE SPEAR TYP WOW II d II A II d II A II 1WW 11 11 1 11 11 SPEAR TOP •••••FLAT TOP W/ 1 -5/8" SPACING 11 11 1 11 11 11 1 STAGGERED SPEAR A fl 11 11 �RA 11 1 11 11 11 11 CONVEX FOR FENCE DESIGNS OTHER THAN 'C' AND 'E': DESIGN SCHEDULE FOOTER SCHEDULE 11 IlIlIlIlIlIlIlIll 11111 SPEAR TOP W/ 1 -5 /8" SPACING I I CONCAVE 11 11 11 11 FLAT TOP WITH SPEAR A FOR FENCE DESIGNS 'C' AND 'E': DESIGN SCHEDULE FOOTER SCHEDULE A TT 11 11 11 11 11 11 11 11 FLAT TOP i *NOTE: FOR INSTALLATIONS WITHIN THE HVHZ WITH MAX HEIGHT OF 6' -0 ", USE WIND LOAD OF 17.7 PSF, BASED ON 90 MPH WIND SPEED, EXPOSURE C PER ASCE 7 -02 (REF. 2004 FBC 1612.2.1). VALID FOR ( 1 ) JOB : Y VALID ONLY WITH RAISED ENGINEERS FRANK L. BENNARDO, P.E. # PE0046549 a 0 el LL° to O " CO tO J , LL o LL > o - p J3$ 1 Q^0c a o C O ,, G O LL v ILL w L.L. 0 a O N M '- o M E W J O Za+ a B w = ` " X aW > 0 ? LU [Dl0 W ° e4 � CI c g U Z LLI to Nom„ 0 LU z 1 1 1 1 bre IN ihi P COPYRIGHT FRANK L BENNARDO PE 00 -GMF -1008 SCALE: 101 PAGE DESCRIPTION: OF AT GRADE MECHANICAL FENCE 1 c3 5 2 1 0 0 1 0 •a LL - . FENCE EXTRUSIONS ALUMINUM ALLOY SHALL BE 6063 -T6, UNLESS NOTED OTHERWISE. EXTRUSION TOLERANCES TO BE PER INDUSTRY STANDARDS • • • • • • • • • • • • • • • • • • 1 1.— • •••• •• o • • o • •O• • • • • r t i 0.050" }- 2.016 " -4 SNAP PLATE HR -11 n = 1'-0" 0.065" t_ 1.795" -1 SNAP PLATE HR -2 6" = 1' -0" Lf 0.045" 1.625" —} SNAP PLATE HR -12P - r 0 0 0 • BOTTOM °• HR -12 n y •• 1 -0 " ••• • • • • •• •• • • x'•16 • I 9 r ---,, r T C 0 0 0 1 " = 1'-0" • • •• •. • • SNAP POST HR-4 1 -0" 2.950" 3" SNAP POST 0.750" 0.038" 0 3/4" ROUND PICKET HR -13R n = 1'-0" 0.750" 0.750"4---f 3/4" SQUARE PICKET HR -13 6" = 1' -0" 4- co • 0.075" }- 1.795 " BOTTOM CHANNEL HR -3 =v-on 6" = 1' -0" 4" TOP CAP 0.055" 1.000" 1" ROUND PICKET HR -5R 6" = 1' -0" 0.040" 1.000" 1.000 "j ---f 1" SQUARE PICKET HR -5 6" = 1' -0" f 2.000 " ---f 1 " 0 0 0 0.115" 1 "x2" TUBE r --2-7/8" 3 -5/8" HR -10 TOP CAP WALL BRACKET HR -10R TOP CAP WALL BRACKET t----11 -1/2" Vn J 1-1.919.-4 TOP CAP HR -1 6" = 1' -O" 6" = 1 -0" N TOP CAP HR -10R ALUMINUM CAST WALL BRACKETS L 2- 1/4 "—} t..1 -1/2" -t WALL BRACKET HR -3 BOTTOM CHANNEL BRACKET _. -3/8 " 1.980" r0.063" rn TOP CAP HR-14 = 1' -0 TOP CAP HR-10 =11-00 0.039" ALT. HORIZ RAIL SNAP PLATE 6 " = 1' -0" 1—} 1 1/4" C HR - TOP CAP HR -1 TOP CAP WALL BRACKET O O L c 1-1 "4 HR -12 BOTTOM CHANNEL BRACKET 0.078" t-- 1.500 " —t ALTERNATE HORIZ RAIL 6" = 1' -0" 6063 -T5 1.275" 1 00 co 0.078" a0 L 1 0.782" ALT. HORIZ RAIL SLEEVE 6" = 1' -0" 6063 -T5 FRANK L. BENNARDO, P. E. # PE0046549 VALID FOR (1) JO =rn . YLY VALID ONLY WITH RAISED ENGINEER SEAL s w ej C2 0 -J LL 0 J Lu O 0 U o 0 1 o a 4.0 O ,� 0 0 PI O a M to ti Co 0 M 1 • • I=1 COPYRIGHT FRANK L BENNARDO P.E 00 -GMF -1008 101 SCALE: PAGE DESCRIPTION: OF3 install new aluminum fence SV Passed 4144fiv r Inspector Comments cc q,,4_ --- Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Date: 09/04/2008 Inspector: Grande, Claudio Owner: KURACK, JOHN Job Address: 10538 4 Avenue NE Project: <NONE> Miami Shores, FL 33138- Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Contractor: SOUTHERN ENGINEERING CONSTRUCTION LLC Building Department Comments Permit Type: Fence/Wall Inspection Type: Final Wor, - ssifcation: Iron /Ornamental Block: Phone Number Parcel Number 1122310130200 Lot: Phone: (305)251 -3000 Wednesday, September 3, 2008 Page 1 of 2